TEST REPORT Nº 2015EP2796

DATE OF RECEPTION APPLICANT


16/11/2015
KERMEL
20 RUE AMPERE
FR-68000 COLMAR
DATE TEST Starting: 23/11/2015
FRANCE
Ending: 11/01/2016
Att. *Romain ZEGANADIN

DESCRIPTION AND SAMPLES REFERENCED:


IDENTIFICATION OF
SAMPLES -“FABRIC: K-FLAME XTRA 165 (K-DURASHIELD 165)”.
Asociación de Investigación de la Industria Textil – C.I.F.: G03182870

TESTS CARRIED
OUT - HEAT TRANSFER EVALUATION OF FLAME RESISTANT MATERIALS
- FLAME RESISTANCE OF TEXTILES (VERTICAL TEST)
- HEAT RESISTANCE
- MASS PER UNIT AREA

ENAC is a signatory to the Multilateral Agreement (MLA), (MRA Mutual Recognition Agreement) of
the European Cooperation for Accreditation (EA) and the International Laboratory Accreditation
Cooperation (ILAC), in testing.

ATTACHED --- SAMPLE(S) SEALED PAGE 1 OF 16

Central: Plaza Emilio Sala, 1 Technical Units: Paterna: Tel. 96 131 81 93 Fax: 96 131 81 83 www.aitex.es
E-03801 ALCOY (Alicante) SPAIN Alcoy: Calle Sant Jordi,13 Tel.:+34 96 554 22 00 www.observatoriotextil.com
Tel.:+34 96 554 22 00 info@aitex.es
Fax: +34 96 554 34 94
REPORT Nº 2015EP2796

RESULTS
HEAT TRANSFER EVALUATION OF FLAME RESISTANT MATERIALS
Standard
ASTM F2700-08(2013) modified by NFPA 2112:2012 sec.8.2
Apparatus
Thermal Protective Performance Tester 403-05
Testing date
12/02/2015
Conditioned
24h in indoor ambient conditions at 21 ± 2 ºC and 65 ± 5 % HR
Sample layers
1
Sample description
Beige woven fabric
Mass per unit area
2
164 g/m
Pre-Treatment
Original
Radiant incident heat flux
2
11,23 kW/m
Total incident heat flux
2
84,17 kW/m
Specimen mounting
Relaxed
Test uncertainty
2
0,76 cal/cm
__________________________________________________________________ >>>

PAGE. 2 OF 16
REPORT Nº 2015EP2796

RESULTS
Reference
FABRIC K-FLAME XTRA 165(K-DURASHIELD 165)
Position of the sensor to the specimen
Contact
2 2
Specimen HTP (J/cm ) TPP (cal/cm )
1 33,44 7,99
2 32,31 7,72
3 32,94 7,87
Average 32,90 7,86

Visual examination and evaluation

Property 1 2 3
Melting No. No. No.
Dripping No. No. No.
Break open No. No. No.
Charring Slight, discoloration. Slight, discoloration. Slight, discoloration.
Embrittlement Slight, starts to harden. Slight, starts to harden. Slight, starts to harden.
Ignition Moderate, dark smoke. Moderate, dark smoke. Moderate, dark smoke.
Shrinkage No. No. No.
Sticking No. No. No.

__________________________________________________________________>>>

PAGE. 3 OF 16
REPORT Nº 2015EP2796

RESULTS
Reference
FABRIC K-FLAME XTRA 165(K-DURASHIELD 165)
Position of the sensor to the specimen
Spaced
2 2
Specimen HTP (J/cm ) TPP (cal/cm )
1 51,02 12,19
2 53,17 12,7
3 53,38 12,75
Average 52,52 12,55

Visual examination and evaluation

Property 1 2 3
Melting No. No. No.
Dripping No. No. No.
Break open No. No. No.
Slight, evident Slight, evident Slight, evident
Charring
charring. charring. charring.
Moderate, small Moderate, small Moderate, small
Embrittlement
hardened areas. hardened areas. hardened areas.
Moderate, dark Moderate, dark Moderate, dark
Ignition
smoke. smoke. smoke.
Shrinkage No. No. No.
Sticking No. No. No.

PERFORMANCE LEVEL ACCORDING TO NFPA 2112:2012 PASS

Requisites to be met according to NFPA 2112:2012 sec.7.1.1


2 2
The spaced HTP rating shall be not less than 25 J/cm (6,0 cal/cm ) and a contact HTP rating shall
2 2
not be less than 12.6 J/cm (3,0 cal/cm )
__________________________________________________________________ ///

PAGE. 4 OF 16
REPORT Nº 2015EP2796

RESULTS
HEAT TRANSFER EVALUATION OF FLAME RESISTANT MATERIALS
Standard
ASTM F2700-08(2013) modified by NFPA 2112:2012 sec.8.2
Apparatus
Thermal Protective Performance Tester 403-05
Testing date
14/12/2015
Conditioned
24h in indoor ambient conditions at 21 ± 2 ºC and 65 ± 5 % HR
Sample layers
1
Sample description
Beige woven fabric
Mass per unit area
2
164 g/m
Pre-Treatment
3 washing cycles at 66ºC, according to NFPA 2112:2012 point 8.1.3, and tumble drying at 68ºC.
Radiant incident heat flux
2
11,78 kW/m
Total incident heat flux
2
85,87 kW/m
Specimen mounting
Relaxed
Test uncertainty
2
0,76 cal/cm
__________________________________________________________________ >>>

PAGE. 5 OF 16
REPORT Nº 2015EP2796

RESULTS
Reference
FABRIC: K-FLAME XTRA 165 (K-DURASHIELD 165)
Position of the sensor to the specimen
Contact
2 2
Specimen HTP (J/cm ) TPP (cal/cm )
1 32,39 7,74
2 32,74 7,82
3 35 8,51
Average 33,38 8,02

Visual examination and evaluation

Property 1 2 3
Melting No. No. No.
Dripping No. No. No.
Break open No. No. No.
Charring Slight, discoloration. Slight, discoloration. Slight, discoloration.
Embrittlement Slight, starts to harden. Slight, starts to harden. Slight, starts to harden.
Ignition Slight, slight smoke. Slight, slight smoke. Slight, slight smoke.
Shrinkage No. No. No.
Sticking No. No. No.

__________________________________________________________________ >>>

PAGE. 6 OF 16
REPORT Nº 2015EP2796

RESULTS
Reference
FABRIC: K-FLAME XTRA 165 (K-DURASHIELD 165)
Position of the sensor to the specimen
Spaced
2 2
Specimen HTP (J/cm ) TPP (cal/cm )
1 48,8 11,66
2 49,94 11,93
3 50,43 12,05
Average 49,72 11,88

Visual examination and evaluation

Property 1 2 3
Melting No. No. No.
Dripping No. No. No.
Break open No. No. No.
Slight, evident Slight, evident Slight, evident
Charring
charring. charring. charring.
Moderate, small Moderate, small Moderate, small
Embrittlement
hardened areas. hardened areas. hardened areas.
Moderate, dark Moderate, dark Moderate, dark
Ignition
smoke. smoke. smoke.
Shrinkage No. No. No.
Sticking No. No. No.

PERFORMANCE LEVEL ACCORDING TO NFPA 2112:2012 PASS

Requisites to be met according to NFPA 2112:2012 sec.7.1.1


2 2
The spaced HTP rating shall be not less than 25 J/cm (6,0 cal/cm ) and a contact HTP rating shall
2 2
not be less than 12.6 J/cm (3,0 cal/cm )
__________________________________________________________________ ///

PAGE. 7 OF 16
REPORT Nº 2015EP2796

RESULTS
FLAME RESISTANCE OF TEXTILES (VERTICAL TEST)
Standard
ASTM D6413 / D6413M – 13b

Apparatus
Test cabinet for vertical flammability

Original test date


26/11/2015

Conditioning
24h in indoor ambient conditions at (21 ± 3) ºC and (65 ± 5) % HR

Ambient conditions test


25,1ºC and 26,0 % HR

Face exposed to the flame


Edge

Tested material
Beige woven fabric
Sample size
75 mm x 305 mm

Flame contact time


12 s

Test uncertainty
± 0,69 mm
± 0,31 s

Deviation from the Standard


---

Reference
FABRIC: K-FLAME XTRA 165 (K-DURASHIELD 165)

__________________________________________________________________ >>>

PAGE. 8 OF 16
REPORT Nº 2015EP2796

RESULTS
Pretreatment
Original fabric
Specimen direction
Warp
(*) Melting and (*)
Specimen After-flame time (s) Afterglow time (s) Char length (mm)
dripping
Specimen 1 0,0 1,2 No 83,2
Specimen 2 0,0 1,2 No 92,8
Specimen 3 0,0 1,2 No 83,2
Specimen 4 0,0 1,2 No 99,2
Specimen 5 0,0 1,2 No 86,4
(*)
Average 0,0 1,2 No 89,6
Specimen direction
Weft
(*) Melting and (*)
Specimen After-flame time (s) Afterglow time (s) Char length (mm)
dripping
Specimen 1 0,0 1,2 No 86,4
Specimen 2 0,0 1,4 No 80,0
Specimen 3 0,0 1,2 No 86,4
Specimen 4 0,0 1,4 No 89,6
Specimen 5 0,0 1,2 No 92,8
(*)
Average 0,0 1,2 No 86,4

Remark

Each individual after-flame time value is rounded to the nearest 0,2 s, as well as the average
calculated of these values.
Each individual char length value is rounded to the nearest 3,2 mm, as well as the average calculated
of these values.

Requisites to be met according to NFPA 2112:2012

No specimen shall give flaming or molten debris


The average of the after-flame time values shall be ≤ 2 s.
The average of the char length values shall be ≤ 100 mm.

_____________________________

PAGE. 9 OF 16
REPORT Nº 2015EP2796

RESULTS
FLAME RESISTANCE OF TEXTILES (VERTICAL TEST)
Standard
ASTM D6413 / D6413M – 13b

Apparatus
Test cabinet for vertical flammability

Original and after pretreatment test date


26/11/2015 - 11/01/2016

Conditioning
24h in indoor ambient conditions at (21 ± 3) ºC and (65 ± 5) % HR

Ambient conditions test


25,1ºC and 26,0 % HR – 23,0 ºC and 44,5 % HR

Face exposed to the flame


Edge

Tested material
Beige woven fabric
Sample size
75 mm x 305 mm

Flame contact time


12 s

Test uncertainty
± 0,69 mm
± 0,31 s

Deviation from the Standard


---

Reference
FABRIC: K-FLAME XTRA 165 (K-DURASHIELD 165)

__________________________________________________________________ >>>

PAGE. 10 OF 16
REPORT Nº 2015EP2796

RESULTS
Pretreatment
Original fabric
Specimen direction
Warp
(*) Melting and (*)
Specimen After-flame time (s) Afterglow time (s) Char length (mm)
dripping
Specimen 1 0,0 1,2 No 83,2
Specimen 2 0,0 1,2 No 92,8
Specimen 3 0,0 1,2 No 83,2
Specimen 4 0,0 1,2 No 99,2
Specimen 5 0,0 1,2 No 86,4
(*)
Average 0,0 1,2 No 89,6
Specimen direction
Weft
(*) Melting and (*)
Specimen After-flame time (s) Afterglow time (s) Char length (mm)
dripping
Specimen 1 0,0 1,2 No 86,4
Specimen 2 0,0 1,4 No 80,0
Specimen 3 0,0 1,2 No 86,4
Specimen 4 0,0 1,4 No 89,6
Specimen 5 0,0 1,2 No 92,8
(*)
Average 0,0 1,2 No 86,4
Pretreatment
100 washing cycles at 66ºC, according to NFPA 2112:2012 point 8.1.3, and tumble drying at 68ºC.
Specimen direction
Warp
(*) Melting and (*)
Specimen After-flame time (s) Afterglow time (s) Char length (mm)
dripping
Specimen 1 0,0 1,4 No 86,4
Specimen 2 0,0 1,4 No 92,8
Specimen 3 0,0 1,4 No 92,8
Specimen 4 0,0 1,2 No 92,8
Specimen 5 0,0 1,0 No 96,0
(*)
Average 0,0 1,2 No 92,8
Specimen direction
Weft
(*) Melting and (*)
Specimen After-flame time (s) Afterglow time (s) Char length (mm)
dripping
Specimen 1 0,0 0,8 No 92,8
Specimen 2 0,0 1,0 No 86,4
Specimen 3 0,0 1,0 No 89,6
Specimen 4 0,0 1,0 No 89,6
Specimen 5 0,0 1,0 No 92,8
(*)
Average 0,0 1,0 No 89,6

PAGE. 11 OF 16
REPORT Nº 2015EP2796

RESULTS
Remark

Each individual after-flame time value is rounded to the nearest 0,2 s, as well as the average
calculated of these values.
Each individual char length value is rounded to the nearest 3,2 mm, as well as the average calculated
of these values.

PERFORMANCE LEVEL ACCORDING TO NFPA 2112:2012 PASS

Requisites to be met according to NFPA 2112:2012

No specimen shall give flaming or molten debris


The average of the after-flame time values shall be ≤ 2 s.
The average of the char length values shall be ≤ 100 mm.

_____________________________

PAGE. 12 OF 16
REPORT Nº 2015EP2796

RESULTS
HEAT RESISTANCE
Standard
NFPA 2112:2012 point 8.4
Apparatus
Air stove
Temperature
(260 +6/-0) ºC
Length of the test
5 min (+0,15/-0) min
Deviation from the Standard
---
Test Uncertainty
± 0,6 %
Pre-treatment
In original

Tested material
Beige woven fabric

Reference
FABRIC K-FLAME XTRA 165(K-DURASHIELD 165)

Fabric
Ignition Melting Dripping Separation Shrinkage
Warp -7,7 %
No No No No
Weft -7,9 %
Warp -8,4 %
No No No No
Weft -8,2 %
Warp -6,8 %
No No No No
Weft -9,7 %
Warp -7,6 %
Average
Weft -8,6 %

PERFORMANCE LEVEL ACCORDING TO NFPA 2112:2012 PASS

Requisites to meet according to NFPA 2112:2012


a) No layer can ignite
b) No layer can melt or drip
c) No layer can separate
d) No layer shrinks more than 10%

PAGE. 13 OF 16
REPORT Nº 2015EP2796

RESULTS
HEAT RESISTANCE
Standard
NFPA 2112:2012 point 8.4
Apparatus
Air stove
Temperature
(260 +6/-0) ºC
Length of the test
5 min (+0,15/-0) min
Deviation from the Standard
---
Test Uncertainty
± 0,6 %
Pre-treatment
3 washing cycles at 66ºC, according to NFPA 2112:2012 point 8.1.3, and tumble drying at 68ºC

Tested material
Beige woven fabric

Reference
FABRIC: K-FLAME XTRA 165 (K-DURASHIELD 165)

Fabric
Ignition Melting Dripping Separation Shrinkage
Warp -6,0 %
No No No No
Weft -6,1 %
Warp -7,1 %
No No No No
Weft -5,7 %
Warp -6,9 %
No No No No
Weft -6,5 %
Warp -6,7 %
Average
Weft -6,1 %

PERFORMANCE LEVEL ACCORDING TO NFPA 2112:2012 PASS

Requisites to meet according to NFPA 2112:2012


e) No layer can ignite
f) No layer can melt or drip
g) No layer can separate
h) No layer shrinks more than 10%

PAGE. 14 OF 16
REPORT Nº 2015EP2796

RESULTS
MASS PER UNIT AREA

Standard
ASTM D 3776:2013 Option C
Atmosphere for conditioning and testing
Temperature (20±2) ºC
Relative Humidity (65±4) %

Mass per unit Mass per unit Linear mass Linear mass
Reference 2 2
area (on/yd ) area (g/m ) (on/yd) (g/m)
FABRIC: K-FLAME XTRA 165 (K-
DURASHIELD 165) 4.846 164.302 1.060 32.860
__________________________________________________________________ ///

PAGE. 15 OF 16
REPORT Nº 2015EP2796

Lucia Martinez
Head of PPE and Ballistics department

Digitally signed by LUCIA MARTINEZ


MOLTO - NIF:21651425F
Date: 2016.01.20 12:50:10 +01:00
Reason: Responsable
Location: Alcoy

LIABILITY CLAUSES

1.- AITEX is liable only for the results of the methods of analysis used, as expressed in the report and
referring exclusively to the materials or samples indicated in the same which are in its possession, the
professional and legal liability of the Centre being limited to these. Unless otherwise stated, the
samples were freely chosen and sent by the applicant.
2.- AITEX shall not be liable in any case of misuse of the test materials nor for undue interpretation or
use of this document
3.- The original test report is kept in AITEX. An electronic copy of it is delivered to the costumer which
keeps the value from the original one as far as the security properties of the document are not
violated. A hard copy of this report with the AITEX logotype sealed in all the pages, keeps the original
value.
4.- The results are considered to be the property of the applicant, and AITEX will not communicate
them to third parties without prior permission. After one month, AITEX may use the results for
statistical or scientific purposes.
5.- None of the indications made in this report may be considered as being a guarantee for the trade
marks mentioned herein.
6.- In the eventuality of discrepancies between reports, a check to settle the same will be carried out in
the head offices of AITEX. Also, the applicants undertake to notify AITEX of any complaint received by
them as a result of the report, exempting this Centre from all liability if such is not done, the periods of
conservation of the samples being taken into account.
7.- AITEX may include in its reports, analyses, results, etc., any other evaluation which it considers
necessary, even when it has not been specifically requested.
8.- The estimated uncertainties in the tests accredited by ENAC are at the client’ s disposal in AITEX.
9.- The original materials and rests of samples, not subject to test, will be retained in AITEX during the
twelve months following the issuance of the report, so that any check or claim which, in his case,
wanted to make the applicant,should be exercised within the period indicated.
10.- This report may only be sent or delivered by hand to the applicant or to a person duly authorised
by the same.
11.- The results of the tests and the statement of compliance with the specification in this report refer
only to the test sample as it has been analyzed / tested and not the sample / item which has taken the
test sample.
12.- AITEX laboratories are placed in Alcoy.

PAGE. 16 OF 16

You might also like