Download as pdf
Download as pdf
You are on page 1of 20
FLUKE 70 Series Multimeters Service Manual FLUKE Fluke 70 Series INPUT SIGNAL, siiiehs neon eke b LCD TO: piairaL | | oisecay |_| + RANGE & aeecreenes sce: FUNCTION AD CONTROL pe ee my COUNTER U1 ANALOG. CHIP A/D SAMPLES. U2MICROCOMPUTER Figured-t. Overiew = Prot Zi oO o—o- OHMS So] VOLTAGE > SOURCE ~S~o-—4 U1 ANALOG CHIP oo ? MA Aree Ans . Jt Rt ape [ae OFS 51 Rx a v2 : $ cou 22 Figure 3-2. Ohms Function oS Cm Fluke 70 Series 3. Referring to Table 44, set the Decade Resistor or Fluke 5100B to the resistance value indicated in steps I through 6. Verify that the display reading is within the limits shown, To test the 73 meter, apply an input from the DC Voltage Calibrator of +2V de to the V-Ohm and Common input terminals of the UT. Verify that the display reading is between +1960 and +2.040, 4-41. Diode Tost 4-12, DC mA Tost (75 & 77 Only) ‘Totest the 75 and 77 meters, perform the following steps: 1. Set the output of the DC Current Calibrator to zero and connect itto the 300 mA and Common L. Put the UUT in the Diode Test function input terminals of the UUT. NOTE 2. Set the DC Current Calibrator to the output shown in Table 4-5, and verify that the UUT. On Fluke 5100 series calibrators, activate the display reading is within the limits shown, 50M divider override. 418, DC Amps Test Set the DC Current Calibrator for zero output and connect it to the 10A & Common input terminals of the UUT. 2. Apply an input from the DC Voltage 1 Calibrator of +.090V dv to the V-Ohm and Common input terminals of the UUT and verify that the beeper is on, 2. Apply currents as indicated in Table 4-6 and verify the display reading is within the limits shown, Increase the DC Voltage Calibrator output to +.1L0V de and verify that the beeper is off Table 4-2. AC Voltage Test IneuT DISPLAY READING sTEP. z VOLTAGE FREQ 73 75 7 1 27V 400 Hz 2.617 102.783 2.644 to 2.786 2.644 to 2.756 2 27Vv 500 Hz 2.617 to 2.783 2.644 to 2.756 2.844 to 2.736 3 750V 100 Hz 725 10775 733 to 787 793 to 767 4 750V 1000 Hz 725 10.778 733 to 787 733 to 767 ‘Table 4-3, OC Voltage Test DISPLAY READING step Dc INPUT VOLTAGE By Zr 7 ) 7 va7v 2.680 t0 2.720 2.885 1 2.715 2601 to 2.700 2 ZV 26.80 10 27.20 26.85 to 27.15, 28.81 to 27.09 3 +2109 268.0 t0 2720, 268.5 10 271.5 259.1 10270.9 4 +1000 991 to 1009 993 to 1007 1995 to 1005, st +300 mV 297.8 to. 302.2 298.4 10 201.6 299.0 to 301.0, “00mV function only Table 4-4, Resistance Test DISPLAY READING ver INPUT DISPLAY AEs | RESISTANCE Py oe "7 7 1000 988 to 101.2 98.1 to 1008 993 to 100.7 2 10090, 989 to 1011 1992 to 1008 ‘964 to 1096 a 10KA | a.80 te 10.11 9192 te 10.08 9.84 to 10.08 4 100 «a | 98.90 104.4 90.2 te 1008 99.4 101006 | 5 imo | 1989 {0 1.011 992 to 1.008 984 to 1.006 6 10 M0 | 262 to 1031 974 t0 10.26 3.79 19 10.21

You might also like