Staggered Rammed Stone Column (900mm Dia)
Staggered Rammed Stone Column (900mm Dia)
1173
TP TECH PECIFIC
MIN: ULTIMATE LOAD ON PILE =370 KN STRUCTURAL CONSULTANTS
1.6667 1.6667
Morth No:-RW/NH-34054/1/2014-S&R(B) Category=II(17)
Staggered Rammed ULTIMATE LOAD SHOULD BE VERIFIED FROM THE
TEST PILE AS PER IS 15284 Office: Plot No.-40, Sector-82, Mohali
1.7550 stone column Mob. No.- +91-8968012763
(900mm dia) COMPACTION REQUIREMENT SHOULD BE AS PER E-mail: techpecific@gmail.com
MORTH SPECIFICATION NO. 305.2.2.4
1.7550
SIZE OF
CRUSHED AGG. % PASSING
OGL LVL
RE WALL
75 90-100
50 80-90
COMPACTED SAND FILLING
38 55-75
20 10-20
RE WALL
PCC LVL. 12 5-13
2 5
GSB GSB
RAMMED STONE
COLUMN (TYP.)
PROJECT:
ROB CROSSING NO. 117
KESRI BIHTA ROAD
AMBALA
CLIENT:
PWD B&R AMBALA
DRAWING TITLE:
TYP. SECTION THROUGH RAMMED STONE COLUMN SHEET NO. REVISION NO.