Rockwell PLC-5 to Modicon

M580 with Unity Pro


Upgrading your control system is easier than you think.

Challenges you may be facing:


• Unexpected downtime due to aging equipment
• Difficulty supporting multiple PLC platforms and programming
software packages
• Preserving the investment in your existing system during an upgrade
• Reduction in skills and/or staff at your plant From To
Rockwell PLC-5® ModiconTM M580
• Limited scheduled downtime during upgrades

Benefits of migrating to M580:


• Minimum downtime and risk to upgrade — do it during planned maintenance “I want to thank the Schneider Electric
• Retain prior investment in software and field wiring services team for our migration from
• Reduce unplanned downtime and enhance cybersecurity Rockwell to the Modicon system.
• Productivity benefits from a new, more transparent, future-proof solution Because our sodium hypochlorite
• Supported by Schneider Electric global service and execution capabilities system is our plant’s primary means
of disinfection, it was imperative that
Solutions and services for a smoother modernization a quick, seamless migration took
• Extensive experience with successful PLC-5 to M580 migrations place. Our project of migrating to an
• Automatic conversion of your PLC-5 application into UnityTM Pro improved PLC was done in a highly
• Stepwise upgrades in phases to meet your budget and schedule satisfactory manner. Thank you!”
• Retain your existing I/O and racks if required
Controls Engineer — Water/Wastewater plant
• Quick wiring solutions eliminate the time and risk of rewiring existing I/O

Switch to Modicon M580 with Unity Pro


Replace CPU with Unity M580 and retain application program with Automated efficiency Minimal downtime
a conversion service. Choose the preferred I/O rack and wiring Repeatable, reliable Typically 1 hour
solution — partial, stepwise, or full: processing with our migration time per
conversion software eight-slot rack

Partial: Stepwise:
Legacy CPU Retain Change Full: Full PLC application conversion
Targeted CPU
and I/O I/O racks I/O racks, replacement
and wiring retain wiring and software upgrade:

PLC-5 CPU Automatic conversion1


and of PLC-5 application
PLC-5 I/O to Unity Pro
Modicon M580

1
Some applications may require minor adjustments
Migration solutions for Rockwell PLC-5
Software upgrade to Unity Pro Benefits
Our proprietary software converter enables efficient conversion of your PLC-5 application
to the Unity Pro platform: For software
• Retention of prior
• Retain the look, feel, and function of your legacy applications investment in
• Build on them by adding programming sections using the latest programming PLC-5 programs
languages, functions, objects, and libraries of Unity Pro • Reduced risk
and errors due to
automatic conversion
of legacy programs
• Reduced time
to complete —
migrations can be
done in scheduled
maintenance
downtime windows
Before conversion After conversion
For hardware
Hardware upgrade • Retention of prior
investment in existing
Partial PLC upgrade to Modicon M580, retaining legacy I/O racks and wiring: racks and/or wiring
• Simplified
modernization
M580
with no rewiring
and reduced
Gateway commissioning time
M580 CPU • Flexibility to upgrade
in phases — address
operational or
budget constraints
Modicon M580 connects to PLC-5 I/O using Ethernet to Rockwell Remote I/O gateway

Total PLC upgrade to Modicon M580


and new X80 I/O while retaining field wiring
Time-saving solutions:
M580
Our quick wiring adapters let you change legacy
Rockwell PLC-5 I/O while retaining field wiring:

X80 I/O or Quantum I/O

PLC-5 I/O quick wiring adapters Wiring adapter


X80 I/O or Quantum IO mounted on an M580 PLC

schneider-electric.com/processautomation

©2016 Schneider Electric. All Rights Reserved. Schneider Electric | Life Is On, Modicon, and Unity are trademarks
and the property of Schneider Electric SE, its subsidiaries, and affiliated companies. All other trademarks
are the property of their respective owners. 998-19779409_GMA-US

You might also like