Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

1 Tag Number 26-PDIT-200A

2 Service TRAIN 1 STANBILIZED CRUDE OIL TANK T-2611 LEVEL

3 Line Number Line Size Sch


4 PID Equipment / Vessel No MEX-HK-T01-UD-152 T-2611
GENERAL
5 Line Insulation Compliance Std.
6 Area Classification Certification Class 1, Div 2, Gr C,D FM
7 Enclosure Mounting NEMA 4X In Equipment
8
9 Fluid Phase Density Unit Oil Liquid 855 kg/m3
10 Units Max. Norm Min.
11 Flow Rate
12 Operation Pressure mm H2O 175.8 87.9 30
PROCESS 13 Operation Temperature °C 60 55
CONDITIONS 14 Design Pressure mm H2O 703.1
15 Design Temperature °C 85
16 Viscosity Spec Grav cP
17 Over Pressure Special Conditions
18
19 Instrument Type Aplication Smart, Two Wire Manometric Pressure
20 Housing Material Paint Aluminum, copper free Epoxic
21 Electrical Connection Power Supply 3/4 NPT 24 VCD
22 Output Signal Digital Communication 4-20 mA (Note 2) Hart
23 Accuracy Response Time +/- 0.065% Span By Mrf
TRANSMITTER kg/cm2-g 0 2
24 Instrument Range Min. Instrument Range Max.
25 Calibration Range Min. Calibration Range Max. kg/cm2-g 0 2
26 Surge Protec. Device RFI Protection Required Required
27 Span-Zero Adjust Remote
28
29 Body Matl Wetted O-ring Matl Bolt Matl SS 316 SS 316 SS 316
30 Proc. Conn. High: Type Size - Rating Flanged 2"Ø; RF; 300#
31 Proc. Conn. Low: Type Size - Rating Threaded 1/2" NPT
BODY / 32 Overrange Protection Allow. Opere. Temp. 1.3
ELEMENT 33 Element Type Element Material Fill Fluid pacitive or Strain gauge SS 316 By Mfr
34 Vent / Drain
35
36 Seal Type-Style Seal Size-Rating --- ---
37 Quantity Diaphragm Material --- ---
38 Housing Material ---
DIAPHRAGM --- ---
39 Fill Fluid Flushing
SEAL
40 Connection of Remote Seal to meter Body ---
41 Capillary Type Capillary length --- ---
42 Capillary armor material ---
43 Integral LCD display Scale Yes Engineering Units
44 Manifold Type Size-Rating Material --- --- ---
ACCESSORIES 45 Packing Material ---
46 Remote Indicator Not Required
47 Testing Required
48 Manufacturer
PURCHASE 49 Model
50 Requisition No MEX-HK-GEN-IJ-109

Notes:
1. Stability effect: +/- 0.125% URL / 5 años; Environment Temperature effect: +/- (0.0125% URL + 0.0625% Span)
2. The provider must indicate the transmitter's output signal according to the ATG system that he proposes

DIFFERENTIAL PRESSURE INDICATING


A 28-FEB-2019 AGC MVP MRF Issued for Information TRANSMITTER
REV DATE BY CHECK. APPR. DESCRIPTION
1 Tag Number 26-PDIT-200B
2 Service TRAIN 2 STANBILIZED CRUDE OIL TANK T-2621 LEVEL

3 Line Number Line Size Sch


4 PID Equipment / Vessel No MEX-HK-T01-UD-152 T-2621
GENERAL
5 Line Insulation Compliance Std.
6 Area Classification Certification Class 1, Div 2, Gr C,D FM
7 Enclosure Mounting NEMA 4X In Equipment
8
9 Fluid Phase Density Unit Oil Liquid 855 kg/m3
10 Units Max. Norm Min.
11 Flow Rate
12 Operation Pressure mm H2O 175.8 87.9 30
PROCESS 13 Operation Temperature °C 60 55
CONDITIONS 14 Design Pressure mm H2O 703.1
15 Design Temperature °C 85
16 Viscosity Spec Grav cP
17 Over Pressure Special Conditions
18
19 Instrument Type Aplication Smart, Two Wire Manometric Pressure
20 Housing Material Paint Aluminum, copper free Epoxic
21 Electrical Connection Power Supply 3/4" NPT Loop
22 Output Signal Digital Communication 4-20 mA (Note 2) HART
23 Accuracy Response Time +/- 0.065% Span 100 ms
TRANSMITTER kg/cm2-g 0 2
24 Instrument Range Min. Instrument Range Max.
25 Calibration Range Min. Calibration Range Max. kg/cm2-g 0 2
26 Surge Protec. Device RFI Protection Required Required
27 Span-Zero Adjust External
28
29 Body Matl Wetted O-ring Matl Bolt Matl Stainless Steel By Manufacturer Stainless Steel
30 Proc. Conn. High: Type Size - Rating Flanged 2"Ø; RF; 300#
31 Proc. Conn. Low: Type Size - Rating Threaded 1/2" NPT
BODY / 32 Overrange Protection Allow. Opere. Temp. Required
ELEMENT 33 Element Type Element Material Fill Fluid By Manufacturer Stainless Steel Silicone
34 Vent / Drain ---
35
36 Seal Type-Style Seal Size-Rating --- ---
37 Quantity Diaphragm Material --- ---
38 Housing Material ---
DIAPHRAGM --- ---
39 Fill Fluid Flushing
SEAL
40 Connection of Remote Seal to meter Body ---
41 Capillary Type Capillary length --- ---
42 Capillary armor material ---
43 Integral LCD display Scale Required Engineering Units
44 Manifold Type Size-Rating Material 5 Way 1/2" NPT Stainless Steel
ACCESSORIES 45 Packing Material By Manufacturer
46 Remote Indicator ---
47 Testing Required
48 Manufacturer
PURCHASE 49 Model
50 Requisition No MEX-HK-GEN-IJ-109

Notes:
1. Stability effect: +/- 0.125% URL / 5 años; Environment Temperature effect: +/- (0.0125% URL + 0.0625% Span)
2. The provider must indicate the transmitter's output signal according to the ATG system that he proposes

DIFFERENTIAL PRESSURE INDICATING


A 28-FEB-2019 AGC MVP MRF Issued for Information TRANSMITTER
REV DATE BY CHECK. APPR. DESCRIPTION
1 Tag Number 65-PDIT-120
2 Service OFF SPECIFICATION OIL TANK LEVEL

3 Line Number Line Size Sch


4 PID Equipment / Vessel No MEX-HK-T01-UD-176 T-6501
GENERAL
5 Line Insulation Compliance Std.
6 Area Classification Certification Class 1, Div 2, Gr C,D FM
7 Enclosure Mounting NEMA 4X In Equipment
8
9 Fluid Phase Density Unit Oil Liquid 855 kg/m3
10 Units Max. Norm Min.
11 Flow Rate
12 Operation Pressure mm H2O 175.8 87.9 30
PROCESS 13 Operation Temperature °C 60 55
CONDITIONS 14 Design Pressure mm H2O 703.1
15 Design Temperature
16 Viscosity Spec Grav Cp
17 Over Pressure Special Conditions
18
19 Instrument Type Aplication Smart, Two Wire Manometric Pressure
20 Housing Material Paint Aluminum, copper free Epoxic
21 Electrical Connection Power Supply 3/4" NPT Loop
22 Output Signal Digital Communication 4-20 mA (Note 2) HART
23 Accuracy Response Time +/- 0.065% Span 100 ms
TRANSMITTER kg/cm2-g 0 2
24 Instrument Range Min. Instrument Range Max.
25 Calibration Range Min. Calibration Range Max. kg/cm2-g 0 2
26 Surge Protec. Device RFI Protection Required Required
27 Span-Zero Adjust External
28
29 Body Matl Wetted O-ring Matl Bolt Matl Stainless Steel By Manufacturer Stainless Steel
30 Proc. Conn. High: Type Size - Rating Flanged 2"Ø; RF; 300#
31 Proc. Conn. Low: Type Size - Rating Threaded 1/2" NPT
BODY / 32 Overrange Protection Allow. Opere. Temp. Required
ELEMENT 33 Element Type Element Material Fill Fluid By Manufacturer Stainless Steel Silicone
34 Vent / Drain ---
35
36 Seal Type-Style Seal Size-Rating --- ---
37 Quantity Diaphragm Material --- ---
38 Housing Material ---
DIAPHRAGM --- ---
39 Fill Fluid Flushing
SEAL
40 Connection of Remote Seal to meter Body ---
41 Capillary Type Capillary length --- ---
42 Capillary armor material ---
43 Integral LCD display Scale Required Engineering Units
44 Manifold Type Size-Rating Material 5 Way 1/2" NPT Stainless Steel
ACCESSORIES 45 Packing Material By Manufacturer
46 Remote Indicator ---
47 Testing Required
48 Manufacturer
PURCHASE 49 Model
50 Requisition No MEX-HK-GEN-IJ-109

Notes:
1. Stability effect: +/- 0.125% URL / 5 años; Environment Temperature effect: +/- (0.0125% URL + 0.0625% Span)
2. The provider must indicate the transmitter's output signal according to the ATG system that he proposes

DIFFERENTIAL PRESSURE INDICATING


A 28-FEB-2019 AGC MVP MRF Issued for Information TRANSMITTER
REV DATE BY CHECK. APPR. DESCRIPTION
1 Tag Number 26-TT-200A
2 Service TRAIN 1 STANBILIZED CRUDE OIL TANK T-2611 LEVEL

3 Line Number Line Size Sch


4 PID Equipment / Vessel No MEX-HK-T01-UD-152 T-2611
GENERAL
5 Line Insulation Compliance Std.
6 Area Classification Certification Class 1, Div 2, Gr C,D FM
7 Enclosure Mounting NEMA 4X In Equipment
8
9 Fluid Phase Density Unit Oil Liquid 855.4 kg/m3
10 Units Max. Norm Min.
11 Flow Rate
12 Operation Pressure mm H2O 175.8 87.9 30
PROCESS 13 Operation Temperature °C 60 55
CONDITIONS 14 Design Pressure mm H2O 703.1
15 Design Temperature °C 85
16 Viscosity Spec Grav
17 Over Pressure Special Conditions
18 Max. Fluid Velocity
19 Instrument Type Smart, Two Wire
20 Input Type Output Signal Multi-Input; (16 Elements RTD) 4-20 mA / Hart ( Note 2)
21 Housing Material Paint Aluminum, copper free
22 Electrical Connection Power Supply 3/4"Ø NPT Loop
23 Digital Communication ---
24 Accuracy Response Time ±0.05 °C 4 s (update time)
TRANSMITTER 25 Instrument Range Min. Instrument Range Max. °C -200 250
26 Calibration Range Min. Calibration Range Max. °C 0 100
27 Transient Protection Required
28 Common Mode Reject Normal Mode Reject 100 db 70 db
29 Integral Display Scale No Required ---
30
31
32 Type Tolerance Class Multi-Input(16 Elements RTD) 1/6 DIN Class B (Note 1)
33 Sensor Assembly Sensor Length. Note 3 15000 mm
34 Sheath Sheath Material By Mfr By Mfr
ELEMENT 35 Sheath Diameter Quantity By Mfr 1
36 Temperature Coefficient Nominal resistence 0°C --- 0°C @ 100 OHM
37 No. Wires Plug / Socket 4 wires By Mfr
38
39 Tag Thermowell Construction type --- ---
40 Thermowell material Shank style --- ---
41 Proces.Conn.Size/Rating Connection to Instrument --- ---
42 Insertion length "U" Lagging extension "T" --- ---
THERMOWELL 43 Bore diameter "B" Base diameter "Q" --- ---
44 Tip diameter "V" ---
45 plug and chain required ---
46 Stamped Treatment --- ---
47
48 Manufacturer By Manufacturer
PURCHASE 49 Model By Manufacturer
50 Requisition No MEX-HK-GEN-IJ-109

Notes:
1. Effect due to differences in wire / connection resistance: ± (0.050 + 0.002 *[T°C]); Effect by characteristics of the element: Pt-100: ± 0.21°C; Uncertainty for the
determination of the Standard Net Volume (NSV): ± 0.32°C.
2. The provider must indicate the transmitter's output signal according to the ATG system that he proposes
3. Multiple Spot Temperature Sensor with integrated water level sensor acuracy ± 2 mm (0.08 in.) [500 mm active length]; Process Connection 2"Ø; RF; 150#

MULTI-INPUT TEMPERATURE
A 28-FEB-2019 AGC MVP MRF Issued for Information TRANSMITTER
REV DATE BY CHECK. APPR. DESCRIPTION
1 Tag Number 26-TT-200B
2 Service TRAIN 2 STANBILIZED CRUDE OIL TANK T-2621 LEVEL

3 Line Number Line Size Sch


4 PID Equipment / Vessel No MEX-HK-T01-UD-152 T-2621
GENERAL
5 Line Insulation Compliance Std.
6 Area Classification Certification Class 1, Div 2, Gr C,D FM
7 Enclosure Mounting NEMA 4X In Equipment
8
9 Fluid Phase Density Unit Oil Liquid 855.4 kg/m3
10 Units Max. Norm Min.
11 Flow Rate
12 Operation Pressure mm H2O 175.8 87.9 30
PROCESS 13 Operation Temperature °C 60 55
CONDITIONS 14 Design Pressure mm H2O 703.1
15 Design Temperature °C 85
16 Viscosity Spec Grav
17 Over Pressure Special Conditions
18 Max. Fluid Velocity
19 Instrument Type Smart, Two Wire
20 Input Type Output Signal Multi-Input; (16 Elements RTD) 4-20 mA / Hart ( Note 2)
21 Housing Material Paint Aluminum, copper free
22 Electrical Connection Power Supply 3/4"Ø NPT Loop
23 Digital Communication ---
24 Accuracy Response Time ±0.05 °C 4 s (update time)
TRANSMITTER 25 Instrument Range Min. Instrument Range Max. °C -200 250
26 Calibration Range Min. Calibration Range Max. °C 0 100
27 Transient Protection Required
28 Common Mode Reject Normal Mode Reject 100 db 70 db
29 Integral Display Scale No Required ---
30
31
32 Type Tolerance Class Multi-Input(16 Elements RTD) 1/6 DIN Class B (Note 1)
33 Sensor Assembly Sensor Length. Note 3 15000 mm
34 Sheath Sheath Material By Mfr By Mfr
ELEMENT 35 Sheath Diameter Quantity By Mfr 1
36 Temperature Coefficient Nominal resistence 0°C --- 0°C @ 100 OHM
37 No. Wires Plug / Socket 4 wires By Mfr
38
39 Tag Thermowell Construction type --- ---
40 Thermowell material Shank style --- ---
41 Proces.Conn.Size/Rating Connection to Instrument --- ---
42 Insertion length "U" Lagging extension "T" --- ---
THERMOWELL 43 Bore diameter "B" Base diameter "Q" --- ---
44 Tip diameter "V" ---
45 plug and chain required ---
46 Stamped Treatment --- ---
47
48 Manufacturer By Manufacturer
PURCHASE 49 Model By Manufacturer
50 Requisition No MEX-HK-GEN-IJ-109

Notes:
1. Effect due to differences in wire / connection resistance: ± (0.050 + 0.002 *[T°C]); Effect by characteristics of the element: Pt-100: ± 0.21°C; Uncertainty for the
determination of the Standard Net Volume (NSV): ± 0.32°C.
2. The provider must indicate the transmitter's output signal according to the ATG system that he proposes
3. Multiple Spot Temperature Sensor with integrated water level sensor acuracy ± 2 mm (0.08 in.) [500 mm active length]; Process Connection 2"Ø; RF; 150#

MULTI-INPUT TEMPERATURE
A 28-FEB-2019 AGC MVP MRF Issued for Information TRANSMITTER
REV DATE BY CHECK. APPR. DESCRIPTION
1 Tag Number 65-TT-120
2 Service OFF SPECIFICATION OIL TANK LEVEL

3 Line Number Line Size Sch


4 PID Equipment / Vessel No MEX-HK-T01-UD-176 T-6501
GENERAL
5 Line Insulation Compliance Std.
6 Area Classification Certification Class 1, Div 2, Gr C,D FM
7 Enclosure Mounting NEMA 4X In Equipment
8
9 Fluid Phase Density Unit Oil Liquid 855.4 kg/m3
10 Units Max. Norm Min.
11 Flow Rate
12 Operation Pressure mm H2O 175.8 87.9 30
PROCESS 13 Operation Temperature °C 60 55
CONDITIONS 14 Design Pressure mm H2O 703.1
15 Design Temperature °C 85
16 Viscosity Spec Grav
17 Over Pressure Special Conditions
18 Max. Fluid Velocity
19 Instrument Type Smart, Two Wire
20 Input Type Output Signal Multi-Input; (16 Elements RTD) 4-20 mA / Hart ( Note 2)
21 Housing Material Paint Aluminum, copper free
22 Electrical Connection Power Supply 3/4"Ø NPT Loop
23 Digital Communication ---
24 Accuracy Response Time ±0.05 °C 4 s (update time)
TRANSMITTER 25 Instrument Range Min. Instrument Range Max. °C -200 250
26 Calibration Range Min. Calibration Range Max. °C 0 100
27 Transient Protection Required
28 Common Mode Reject Normal Mode Reject 100 db 70 db
29 Integral Display Scale No Required ---
30
31
32 Type Tolerance Class Multi-Input(16 Elements RTD) 1/6 DIN Class B (Note 1)
33 Sensor Assembly Sensor Length. Note 3 15000 mm
34 Sheath Sheath Material By Mfr By Mfr
ELEMENT 35 Sheath Diameter Quantity By Mfr 1
36 Temperature Coefficient Nominal resistence 0°C --- 0°C @ 100 OHM
37 No. Wires Plug / Socket 4 wires By Mfr
38
39 Tag Thermowell Construction type --- ---
40 Thermowell material Shank style --- ---
41 Proces.Conn.Size/Rating Connection to Instrument --- ---
42 Insertion length "U" Lagging extension "T" --- ---
THERMOWELL 43 Bore diameter "B" Base diameter "Q" --- ---
44 Tip diameter "V" ---
45 plug and chain required ---
46 Stamped Treatment --- ---
47
48 Manufacturer By Manufacturer
PURCHASE 49 Model By Manufacturer
50 Requisition No MEX-HK-GEN-IJ-109

Notes:
1. Effect due to differences in wire / connection resistance: ± (0.050 + 0.002 *[T°C]); Effect by characteristics of the element: Pt-100: ± 0.21°C; Uncertainty for the
determination of the Standard Net Volume (NSV): ± 0.32°C.
2. The provider must indicate the transmitter's output signal according to the ATG system that he proposes
3. Multiple Spot Temperature Sensor with integrated water level sensor acuracy ± 2 mm (0.08 in.) [500 mm active length]; Process Connection 2"Ø; RF; 150#

MULTI-INPUT TEMPERATURE
A 28-FEB-2019 AGC MVP MRF Issued for Information TRANSMITTER
REV DATE BY CHECK. APPR. DESCRIPTION