Catalog Ky Thuat Ray Dien An Toan PDF
Catalog Ky Thuat Ray Dien An Toan PDF
HARD WORK
ISO 9001
1 HARD WORK
3P.4P.6P
Insulated Conductor Rails
▓ 3P (3 Pole / Phase)
50A .75A. 100A. 150A
(3P is used for 3 Phase R.S.T.)
▓ 4P (4 Pole / Phase)
50A. 75A. 100A. 150A
(4P is used for 3 Phase R.S.T & GROUND)
2
▓ End Tension & Power In
M10
B
M10
102 C
350
Weight
Part No . Type A B C
(kg)
▓ Hanger Clamp
A
40
M10X30
Weight
Part No . Type A B C D
(kg) C
3 HARD WORK
▓ Insulated Conductor Rails
3P
3P-Continuous Insulated Conductor Rails
55
Weight
Part No . Rating Length
(kg)
14
H302-50A 600V.50Amp 1m 0.72
H302-75A 600V.75Amp 1m 0.82
H302-100A 600V.100Amp 1m 1.07
H302-150A 600V.150Amp 1m 1.35
4P
4P-Continuous Insulated Conductor Rails 75
Weight
Part No . Rating Length
(kg)
14
H402-50A 600V.50Amp 1m 0.88
H402-75A 600V.75Amp 1m 1.00
H402-100A 600V.100Amp 1m 1.38
H402-150A 600V.150Amp 1m 1.73
6P
115
6P-Continuous Insulated Conductor Rails
Weight
Part No . Rating Length
14
(kg)
H602-50A 600V.50Amp 1m 1.56
H602-75A 600V.75Amp 1m 1.61
▓ Current Collector
HARD WORK
195
Weight
Part No . Rating A B
(kg)
˙ Double Sides Current Collector is used for the application in special
H303-30A 600V.30Amp 0.27 71 461 design of irregular or circle connection at a large amount of current flow.
H303-60A 600V.60Amp 0.30 87 477
HARD WORK 4
▓ Collector
˙Collector is only for replacement that is a consuming parts of Current Collector.
30A 60A
5 71 87
52 68
350
350
Weight
Part No . Rating
(kg)
H304-30A 600V.30Amp 0.065
H304-60A 600V.60Amp 0.095
16
M6X12
7
39
A
U-Shape
11
Copper Connector
120
46
20 20 20
B
Weight
Part No . Type A B
(kg)
H305 3P 0.22 70 61
H405 4P 0.31 90 81
5 HARD WORK
▓ Supports
40
11
40
Weight
Part No . Type A
(kg)
A
13
11 4
30
B 58.7
Weight
Part No . (kg) A B
HARD WORK 6
3P . 4P . 6P
Insulated Conductor Rails Outline Design
50Amp Insulated Conductor Rails is applied in a small type cranes (1~3 tons).
150Amp Insulated Conductor Rails is applied in a multiple type cranes (5~10 tons).
Supports
2 Hanger Clamp
RK
D WO
H AR
3
Insulated Conductor Rails
Current Collector
Hanger Clamp
95±10
M10X30
13
7 HARD WORK
▓ Supports Design
20
20
Hanger Support
φ11
˙The Side Installation is necessary if the 3P.4P.6P ˙The End Tension & Power In of 3P.4P.6P Insulated Conductor Rails
Insulated Conductor Rails is mounted at a radian. have to be installed 5mm higher than the Hanger Clamp to avoid
˙To install a Hanger Clamp in each 0.5 meter from water flowing down to make short circuit.
the start point of the radian. ★ The weathered protection is required if 3P.4P.6P Insulated Cond-
uctor Rails is applied in outdoors.
A B
Screw Bolt M5X18L
End Tension & Power In
Installation Direction
Screw Bolt M6X8L
Insulated Conductor Rails
K
R
O
HARD WO
RK H400
Insulated Conductor Rails
0.5 m 1.5~3 m
Cover ˙Fix End Tension & Power In at one side first, then pull
Insulated Conductor Rails straight and fix it with the
other End Tension & Power In at the other side.
Copper Contact for Power In
C m
Installation Procedures : 0.5 Supports for Hanger Clamp
1. Insert Insulated Conductor Rails to the bottom of End Tension & Power In. 25
2. Use Screw Bolt M5X18L provided to fix Insulated Conductor Rails. 0~
30
0
3. Connect Power Supply wire terminal with Copper Contact by Screw Bolt M6X8L, φ11 For Hanger Clamp
then place the Cover to complete the installation procedures. Enforced Support
A B C
Hanger Clamp
Hanger Clamp
Insulated Conductor Rails
˙Fix Hanger Clamp on Supports by Washer and Nut. ˙Push upward and mount Insulated Conductor Rails ˙Slightly pry up Insulated Conductor Rails
on Hanger Clamp. at both sides from Hanger Clamp by a flat
screwdriver if necessary.
HARD WORK 8
3 How to install Fix Square Bar and Current Collector
A B
YES NO YES
95±10
HARD WORK
195
m
13
m
m
NO
13
m
106
K
HARD WOR
C
1. Mount Fix Square Bar on
Cranes Construction by
welding or screw bolt.
2. Fix Square Bar shall be
installed in parallel with
Insulated Conductor Rails.
Fix Square Bar
NO
Cranes Construction
84
HA R D WO RK
Bar if it is too long to use.
A B C
m /m
35
o
90
Top
90 o Power Supply Wire Terminal
Side
Bottom U-shape Copper Connector
Conductor
Copper Conductor M6 Wrench for M6 Inner
Hexagon screw bolt
(not included)
˙Cut off insulated plastic PVC material at 35mm ˙Bend upward copper conductor material ˙Insert both sides of 90 o
vertical angle Copper
from the end of Insulated Conductor Rails. at a 90o vertical angle. Conductor into Middle Power Feeding and
connect both sides of 90o vertical angle Copper
Conductor by screwing up M6 Inner Hexagon
screw bolt on U-shape Copper Connector.
9 HARD WORK
I -Type
Insulated Conductor Rails
S type Line Case Around type Curve Case Illustration for I -Type
Standard Export Packing
10
▓ I -Type End Tension & Power In ▓ I -Type Hanger Clamp
100 22 39.6
43
47
30
M10X 350
135 295
33.2
37.5
67.5
29.2 10 6
46 50
47
Weight Weight
Part No . Part No .
(kg) (kg)
HI00 0.65 HI01 0.11
157
11. 1
35
20 B
A
11.3
95±10
20
HARD WORK
400
282
6. 5
11 HARD WORK
▓ I -Type Collector ▓ I -Type Middle Power Feeding
˙I-Type Middle Power Feeding is used for connecting I-Type Insulated Con-
˙I-Type Collector is only for replacement that is a consuming parts of I-Type ductor Rails that will be extended or the length of I-Type Insulated Conductor
Collector Shoe. A Rails is over 100 meters to avoid voltage dropping.
139 30
56.5
C
22
18
φ5
80
120
Weight Weight
Part No . Rating A B C Part No .
(kg) (kg)
˙Use I-Type Fixed End Insulator instead of I-Type End Tension & Power In at
one end if the length of I-Type Insulated Conductor Rails is installed less than
30 meters, in order to save the material cost if necessary. I-Type Insulator Hanger is an option for installation outdoors and in dusty places.
42.4
30
27
39
26
9
23
6
33.2
37.5
21.7
11.8
Pin
17 φ5X 20 10 6
39
47
Weight Weight
Part No . (kg) Part No . (kg)
HI06 0.05 HI07 0.15
HARD WORK 12
I -Type
Insulated Conductor Rails Outline Design
I -Type Supports
RK
WO
RD
HA
I -Type Insulated Conductor Rails
R
S
T
1 I -Type End Tension & Power In
Ground
A A A
I-Type Fix Square Bar
A
B2
I -Type
B1
I -Type
Insulated Conductor Rails
m
25
m
m
25
m
13 HARD WORK
▓ Supports Design
0.5m 0.5m
30m
0.5m 0.5m
Line Case
Curve Case
0.5 m
I-Type Middle Power Feeding
Supports for I-Type End Tension & Power In
1
below 6m l h1 h2 m
h 1 =30 / m
h2=9 m/ m
3
below 0.5m
HARD WORK 14
Around type
〝S 〞type
below 0.5m
I-Type
Power fe ed I-Type Hanger Clamp below 0.5m
End Tension & Power In I-Type End Tension & Power In
I-Type
Supports for below 0.5m Hanger Clamp Supports for I-Type
I-Type Hanger Clamp End Tension & Power In
Supports for below 0.5m
I-Type End Tension & Power In
below 0.5m
0.5 m
below 0.5m
Supports for
I-Type Hanger Clamp
15 HARD WORK
1 How to install I -Type End Tension & Power In
A B
˙I -Type End Tension & Power In ˙I -Type End Tension & Power In
mm
90
Terminal Plate
Screw Bolt
Washer with a M8X15
square hole
Terminal
Terminal Plate
Cover
1. Cut off insulated plastic PVC material at 90mm from the 1. Connect Power Cable Wire with Terminal Plate and then
end of I-Type Insulated Conductor Rails. place Cover on I-Type Insulated Conductor Rails.
2. Put Washer and Terminal Plate into Copper Conductor
material of I-Type Insulated Conductor Rails, then bend
backward Copper Conductor material and touch with Ter-
minal Plate.
3. Place Cover on and complete.
Use I -Type Fixed End Insulator instead of I -Type End Tension & Power In if the
total length of I -Type Insulated Conductor Rails is installed in 30 meters.
Pinφ5X20
Supports
13 m/ m
˙Drill a holeφ5 at 13mm from the end of I-Type Insulated Conductor Rails for inserting Pinφ5x20.
A B C
Push Upward
Metal Clip Metal Clip
Press Inward
Press Inward Plastic Clip
Plastic Clip
Press Inward
Press Inward
Pull Downward
Pull Downward
1. Take out Plastic Clip from Metal Clip first. 2. Mount Plastic Clip on I-Type Insulated Conductor Rails 3. Use tool to clip inward Plastic Clip and pull
and then install it together on Metal Clip. I-Type Insulated Conductor Rails out tog-
ether if necessary.
HARD WORK 16
3 How to install I -Type Fix Square Bar and I -Type Insulated Conductor Rails.
A B
I -Type
YES
95±10
Collector Shoe
HARD WORK
Cranes Construction
95±10
M5/16
84
HA RD WO RK
Fix it by welding or screw bolt.
106
ORK
DW
HAR
1. I -Type Fix Square Bar shall be installed in parallel with I -Type Insulated Conductor Rails.
2. Cut the length of I -Type Fix Square Bar if it is too long to use.
*Caution:
YES NO
I -Type Insulated Conductor Rails Incline over 10 O
in vertical and parallel.
10 O
O
1. It is not allowed to incline over 10 when install I -Type
Insulated Conductor Rails.
2. If I -Type Insulated Conductor Rails still incline after
installation, then it is required to adjust forcedly.
A B
Terminal Plate
Copper Plate Flute
Terminal
Power Cable Wire
Wrench for M6
Inner Hexagon
screw bolt
(not included)
I -Type
Insulated Conductor Rails
1. Cut off 80mm long of insulated material PVC in the middle of I -Type Insulated 1. Connect Power cable wire and screw up Cover.
Conductor Rails for supplying power.
2. Contact Copper Conductor of I -Type Insulated Conductor Rails by two piece of
Copper Plate and fix it by M6 inner hexagon screw bolt.
3. Drill two holesφ5mm through both Copper Plate and Copper conductor of I -Type
Insulated Conductor Rails at the bottom and insert pins to connect and fix them.
17 HARD WORK
A Specialist in Safe/Reliable Power and Data
Transfer Systems for Moving Equipment
Flat Cable
Festoon Systems
Heavy Duty
Multipole Connector