Maintenance Software Instruction Manual: Voyage Data Recorder Simplified Voyage Data Recorder
Maintenance Software Instruction Manual: Voyage Data Recorder Simplified Voyage Data Recorder
Maintenance Software
Instruction Manual
7ZPNA4013D
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
RECORD OF REVISIONS
Rev Description Date
TABLE OF CONTENTS
i
DOC No. 7ZPNA4013D
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
ii
DOC No. 7ZPNA4013D
1. Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1. Maintenance Software
1) Software name:
JCY1800-maint.exe
2) Language used:
English
5) OS:
・ Windows XP
・ Windows Vista (SP1 or after it)
Language setting
If the Maintenance PC is not Japanese OS or English OS, please set language to the “English (United States” or
the “English (United Kingdom)” in the Control Panel screen of Windows.
Depending on language, the Maintenance software may not operate normally.
Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.
6) PC:
1
DOC No. 7ZPNA4013D
1. Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
7) Personal Firewall
In case a personal firewall is run on the PC, suspend the function before using the maintenance software.
Personal Firewall
A personal firewall is a filtering facility of LAN communication link attached to OS (Windows XP, Vista) and the
software to detect and isolate a virus.
When a personal firewall is enabled;
The VDR/S-VDR cannot communicate with the maintenance PC.
9)
2
DOC No. 7ZPNA4013D
2. Starting and Quitting the Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3
DOC No. 7ZPNA4013D
2. Starting and Quitting the Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2.1.2.2. Entering User name, Company name and Password (“Register Information”)
1) Register Information
Enter the following user information, which will be recorded onto the VDR/S-VDR.
• User name
• Company name
2) Password
The entered letters are indicated with asterisks (“******”).
This is the password for field engineer. All "jrcvdr" is small letters.
Many models of recent laptop have not only wired LAN but also wireless LAN.
Select “wired LAN” as the interface.
The IP address added for VDR/S-VDR maintenance is deleted when the PC is rebooted.
2.1.2.5. Login
Click the [Next] button.
After successful login to the VDR/S-VDR, “HOME screen” will appear.
4
DOC No. 7ZPNA4013D
2. Starting and Quitting the Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Confirm the following items before logout when the installation is finished
1. All Entry lamps are lit green in the System screen.
2. All Diagnosis lamps are lit green in the System screen.
3. Any error event is not arisen on real time Event monitor.
4. The downloaded data from the capsule can be played back rightly.
5. The copied data from the CF card can be played back rightly.
6. Report files are saved with Report function.
The maintenance software is shut down after logging out from the VDR/S-VDR.
5
DOC No. 7ZPNA4013D
2. Starting and Quitting the Maintenance Software
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
6
DOC No. 7ZPNA4013D
3. Selecting Work Item
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3.2.1. Installation
Select “Installation” for installing, setting and checking the VDR/S-VDR system. Following items are available on
“Installation”.
• As-delivered factory setting
• Field setup
• Operation check of the VDR/S-VDR
• Annual inspection
• In field fault locating and remedy
7
DOC No. 7ZPNA4013D
3. Selecting Work Item
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3.2.2. Playback
* Update of FGB program can be performed from the menu of SYSTEM screen.
8
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
[Installation]
● JCY-1800
9
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
● JCY-1850
10
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Set up and check the VDR/S-VDR on the “SYSTEM” screen according to the following procedure.
Receiving data Real time monitor Check the receiving data by the real time monitor. 7
9 Recorded data Playback Check the recorded data by the Playback software. 10
11
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2) Confirm the reception has been completed with the progress bar.
The configuration data reception process by [Receive] button is improved to high-speed for MCB and RMB
software Ver2.0.1 or later. As a result, the data can be received instantly.
Note that the earlier software version is not compatible for high-speed reception, so that it takes time as
before.
* If the [Diagnosis] button is clicked during the diagnosis function is on, the function will be stopped.
12
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Each channel
Check the check box of connected CH as follows.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
Check box
Caution) Cross out the check mark in the check box when the sensor connection setup is to be undone (from
enable to disable) temporarily. In this case, do not forget to delete the setup data referring to 4.3.3.3.
If the setup data remains when the mark is removed from the check box, the data from the same sensor
may not be recorded via other channel.
1) Selecting CH
Click a radio button of setting sensor channel.
2) Click the [Detail] button on Sensor section, a detail setup window appears.
13
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Select the connection equipment and recording data according to the following procedure.
The default value for receiving the data of the equipment chosen is set up automatically on the detail setting window.
Select “Other”, when there is no appropriate item that should be set up.
Enter an appropriate data for connected equipment on "Data" tab screen.
14
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Click “Do you want to delete information?” and click the [Next] button. The registered setup data is deleted.
In the following cases, delete the setting data of CH which are not connected.
Example) As delivered, CH4 has been assigned as the input port of Gyro angle data in NMEA format. However on
the ship actual Gyro angle is distributed by step signal repeater. Therefore the setup on CH4 has to be
cancelled. Instead, CH33 shall be assigned as the port of Gyro angle data.
1) Setup error
If a setup data remains despite the check on CH4 has been crossed out, the following error dialog will be
displayed immediately after CH33 is checked.
2) Setup procedure
Delete the setup data of the CH4 according to the aforementioned.
Check the check box of CH33.
Enter setup data for receiving the heading data into detail window of CH33.
15
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Selection table
Wind Speed and Direction Anemometer 48 Wind Speed and Direction ??MWV
Rudder Order/Response Autopilot 45 Rudder Order, Manual ??HTD
Rudder Response, Manual ??RSA
Rudder Angle Indicator 46 Rudder Response, Manual ??RSA
ECDIS 51 Rudder Order, Automatic ??HTC
Engine Order/Response M/E Remote Control 50 M/E RPM Set Order(CPP order) ??PRC
System M/E RPM Actual Response(CPP order) ??RPM
Engine Telegraph 49 Telegraph Order Position ??ETL
Thruster Order/Response Thruster 52 Thruster Response ??TRD
Bow1 Thruster 53 Thruster Response ??TRD
Bow2 Thruster 54 Thruster Response ??TRD
Stern1 Thruster 55 Thruster Response ??TRD
Stern2 Thruster 56 Thruster Response ??TRD
Acceleration and Hull Hull Stress Monitor 57 Hull Stress ??HSS
Stress
Door Status Fire Door Status * Fire Door Status ??DOR
Watertight Door Panel * Watertight Door Status ??DOR
Hull Door Controler * Hull Door Status ??DOR
Ramp Way Indicator *
Main Alarms Alarm Monitoring system *
Water Ingress Alarm *
System
Bilge Alarm Panel *
Fire Detection System *
Steering Gear *
AIS Data AIS 42 AIS VDO Data ??VDO
AIS VDM Data ??VDM
Status Information ??TXT
Main Alarm(ALR) ??ALR
Radar Selection Radar(Main) 58 Radar Selection ??PJRC
Other * Other
16
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
17
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Equipment
Enter the name of the connected equipment. (GPS, Echo sounder, etc.)
* Unless “Other” is selected, a default equipment name is entered automatically.
2) Model
Enter the model name of the connected equipment.
3) Manufacturer
Enter the name of the manufacturer of the connected equipment.
4) Serial No.
Enter the serial number of the connected equipment.
* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial
No. column.
18
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4.3.4.2.1. Type
19
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Header
Enter the header character.
Enter “$” for general sensor units.
In case of connecting to the AIS, enter “!” as a header character.
When “!” is entered, the RCU receives the NMEA sentences that have “$” and “!” as header.
2) Delimiter
Enter delimiter (the sign that means the end of the sentence).
“OD OA” is recognized by the software as “<CR><LF>“.
20
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Whether or not a sentence is recorded in the VDR/S-VDR is determined by the sentence ID. Any sentence of which
ID is different from the specified is discarded and is not recorded in the VDR/S-VDR.
1) Recording item
Select record item from the pull-down menu.
Select “Other”, when the item was not found in the menu.
2) Sentence ID
Select a sentence ID from the pull-down menu.
Enter the sentence ID, if the sentence was not found in the menu.
y The talker ID (2 characters) can be entered along with the sentence ID (3 characters).
y An uncertain character also can be entered using “?”.
y Enter as many characters as you like (up to 7 characters).
y At least, include the sentence ID (3 characters).
y Examples: setting sentence ID for filtering ZDA sentences of GPS. ( all OK )
▫ GPZDA ▫ GPZDA?? ▫ ??ZDA ▫ ??ZDA??
3) Watch
The watch on maximum interval of receiving can be set on each sentence.
Set the Watch function of each NMEA sentence to enable or disable.
The VDR/S-VDR will generate an error when the NMEA sentences set as “Enable” are not received within the
set interval time. The VDR/S-VDR will not generate the error alarm when the NMEA sentences set as
“Disable” are not received within the interval time.
21
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
“Entry” lamp informs the service engineer whether the entry is finished or still some items
(Model, Serial number, etc.) remain.
• Transmit
Click the [SET] button.
• Cancel
Click the [Close] button.
Monitors the real time NMEA sentence data which is collected in the RCU, and verify that the sentence specified by
the installation drawings is collected correctly.
1) Procedures
START: Click the [Start] button.
* Real time monitor is automatically started at the opening window.
● “RCV Data”: Monitors all the data that the RCU receives.
The sentence data which is not recorded on the VDR/S-VDR is also displayed.
● “REC data”: Monitors the sentence data which is recorded in the VDR/S-VDR.
The sentence which is not recorded is not displayed even when it has been received.
The monitored data is displayed by the sentence format currently recorded in the
VDR/S-VDR.
22
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
As for the diagnostic result of the [Sensor] section, the result is indicated on the "Diagnosis"
lamp immediately after the setting has been completed.
* Regarding the sections other than [sensor], rebooting after transmitting the setup data to RCU
is required, therefore the “Diagnosis” result cannot be indicated with a lamp at setting.
* To have the diagnostic function operated, click the [Diagnosis] button on “System” screen.
If the function is not on, the “Diagnosis” lamp is off.
23
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Setup screen of GPS is a screen of exclusive use for connected two GPSs.
Sub GPS setting is required when connected two GPSs to one port via a switcher.
1) Equipment
Enter the name of the connected equipment. (GPS, DGPS, etc)
2) Model
Enter the model name of the GPS.
3) Manufacturer
Enter the name of the manufacturer of the GPS.
4) Serial No.
Enter the serial number of the connected equipment.
* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial
No. column.
24
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Set up the “GPS selection” when the “GPS (main+sub)” is selected as a connection equipment.
1) Switch position
Select the logic of dry contact signal which is outputted by a GPS switcher.
The GPS switcher is connected to “TB406 PI-3” which is a terminal in the RCU.
The VDR/S-VDR records the GPS equipment (main or sub) currently recorded as EVENT.
2)Datum
When the GPS does not output DTM, clear the DTM setting.
25
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
CH33 and CH34 of Sensor section are the connection CH with NSK.
Enable / Disable of heading data connection can be set up to CH33.
Enable / Disable of speed data connection can be set up to CH34.
1) Each channel
Check the check box of connected CH as follows.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
Check box
Select the subject CH of set
up
1) Selecting CH
Click the radio button of setting sensor channel.
2) Click the [Detail] button on sensor section. Then detail setting window appears.
26
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Set an identification data of connected equipment which outputs a Synchro signal or a step signal as heading data.
1) Equipment
Enter the name of the connected equipment. (Gyro, etc)
2) Model
Enter the model name of the connected equipment.
3) Manufacturer
Enter the name of the manufacturer of the connected equipment.
4) Serial No.
Enter the serial number of the connected equipment.
* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial
No. column.
27
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4.4.3.2.2. Ratio
When the setup data of "Signal Type", "Ratio", or "Gray Code" are changed, transmit the setup data to RCU
before inputting an initial value of heading.
Click the [Set] button, to finalize the renewed data.
* After the data transmission, RCU is rebooted automatically and setting data will become effective.
28
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Even when the entry of heading angle is not made from OPU, the initial value of heading can be inputted from
Heading TAB screen.
1) Measured Value
The current value of heading is displayed.
The value displayed on this screen is the same as the value displayed on OPU.
* Hading value is not displayed if the Real-time monitor has been stopped.
Start the Real-time monitor in "Rec data" mode.
2) Initial Value
Click the [Send] button after inputting an initial value.
The inputted initial value is registered into the RCU.
* "Initial Value" and "Measured Value" should show the same heading value immediately after the screen is
opened. When the correct heading value is displayed, click the [Send] button without inputting an initial
value.
29
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Set an identification data of connected equipment which output a Pulse signal as ship’s speed data.
1) Equipment
Enter the name of the connected equipment. (Speed log, etc.)
2) Model
Enter the model name of the connected equipment.
3) Manufacturer
Enter the name of the manufacturer of the connected equipment.
4) Serial No.
Enter the serial number of the connected equipment.
* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial
No. column.
4.4.4.2.1. Pulse
30
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
In order to record a dry contact signal and an analog signal on VDR/S-VDR, the Digital Signal Converter (DSC:
NCT-72/63 option) must be connected to the VDR/S-VDR. Set up the DSC following the procedure described
hereunder.
1) Each channel
Check the check box of connected CH as follows.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
Check box
Select the setup CH
1) Selecting CH
Click the radio button for setting sensor channel.
2) Click the [Detail] button on sensor section and the detail setting window appears.
31
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Select the option unit (NCT-72/63) and recording data according to the following procedure.
The initial value for receiving the data of the option unit (NCT-72/63) is set up automatically on the detail setting
window.
32
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
• "Dry Contact" TAB is added as a detailed setting screen of dry contact input.
• When “DSC+A/D” is selected, "A/D" TAB is added as a detailed setting screen of analog signal input.
1) Equipment
"DSC" or "DSC+A/D" is entered automatically.
The interior of the parentheses is Connection channel/equipment.
2) Model
Enter the model name of the connected equipment. (NCT-72/63)
3) Manufacturer
Enter the name of the manufacturer of the connected equipment. (JRC)
4) Serial No.
Enter the serial number of the connected equipment.
33
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
● DSC+A/D
● DSC
34
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4.5.5. Detail setup window of dry contact (Dry Contact TAB screen)
This is the screen for transmitting and receiving the configuration file of NCT-72/63.
2) AT a communication link Monitor display, check that setting data are received.
3) Completion/failure of reception is displayed by a dialog. Verify that the following message appears.
Click the [Setup] button and the screen for the NCT-72/63 setup will appear.
35
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Dry contact data, such as alarm, door (open or close) and others should be changed into NMEA sentences.
The screen for creating conversion table file will appear.
In editing not the configuration file that was received from NCT-72/63 but the configuration file saved, point to
“Open” at File menu list.
Sentence data are set up to each channel which accepts dry contact signal.
● Connection CH
Select a channel which is connected to the dry contact signal.
36
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Alarm
Select the inputting dry contact state (OPEN/CLOSE) when the connected equipment is in normal state.
2) Door
Select the inputting dry contact state (OPEN/CLOSE) when the connected door is open.
Although categories are prepared from 0 to 3, the number of category to be set up is automatically determined by
the selected data.
Be sure to select a dry contact information from the pull-down menu which can be set up.
An unnecessary setup category is not selectable.
37
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Selected sentence
Double-
Click
Be careful not to double select an identification number otherwise the same sentence data will be created
3) Comment
Each sentence can be followed by a comment.
Add a comment to each sentence by which a service engineer recognizes what the signal is.
38
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Selecting a sentence
Double-click the sentence displayed on the list.
The CH number for deletion is displayed.
2) Deleting a sentence
Click the [Delete] button.
2) Editing a sentence
Set up a new sentence data after deletion.
39
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
40
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2)
4)
3)
41
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2) Enable setting
Setup procedure is the same as “Engine telegraph position”.
3) Disable setting
Select “Other”.
42
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The configuration file created to NCT-72/63 is transmitted when all the setup is completed.
2) The setup screen is completed and returns to the Transmit/Receive screen of the configuration file.
The configuration file is transmitted automatically to the NCT-72/63.
1) At the communication link Monitor display, check that setting data are transmitted.
2) Completion/failure of reception is displayed in a dialog. Verify that the following message appears.
43
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The NMEA sentence can be monitored by the real time monitor on the setting screen.
If the following dry contact signal monitor is available, check the sentence with this.
1) Starting
Click the [Monitor] button.
2) Operating
Refer to “7.5”.
44
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3) Sentence setup
Check that the logic of a dry contact signal is correct.
• Alarm Normal: Green lamp / Abnormal: Red lamp
• Door A door icon shows the state of door (Open/Close).
Click Good or No Good according to the diagnostic result.
4) Comment
Enter a comment if the result is NG.
45
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The following data that are inputted on the setup screen of each channel are displayed on this screen.
• Connection signal
• Current value
• Data unit
1) Each channel
Check the check box of connected CH as follows.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
46
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Equipment
Enter the name of the connected equipment.
2) Model
Enter the model name of the connected equipment.
3) Manufacturer
Enter the name of the manufacturer of the connected equipment.
4) Serial No.
Enter the serial number of the connected equipment.
* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial
No. column.
Set up the parameters to translate the A/D conversion value (%) of the ACB into the real value displayed on the
equipment.
1) Selecting CH
Select an analog channel to set up.
47
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
• STEP7: Check that the conversion value on “Check value” and the real value on the equipment are
the same.
Click the [Check] button. The converted value is displayed.
When the converted value is not correct, repeat from STEP1.
Language setting
If the Maintenance PC is not Japanese OS or English OS, analog data may not convert real value correctly,
depending on language.
Please set language to the “English (United States” or the “English (United Kingdom)” in the Control Panel
screen of Windows.
Refer to "17.3 Language setting for Maintenance PC" about the setting method of language.
48
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The specification and information of the analog signal are set up.
1) Data unit
Select the data unit of receiving data.
No. Unit
00 -
01 deg
-1
02 min
03 rpm
04 m/s
05 km/s
06 knots
3) Conversion formula
The coefficients of the conversion formula are inputted automatically.
* Manual input is also possible.
Conversion formula
y=A1*10A2x+B1*10B2
49
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3) Sentence setup
Check that the conversion value is an appropriate value.
Click Good or No Good according to the diagnostic result.
4) Comment
Enter a comment if the result is NG.
50
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The parameters of the following inputs are set up by the strap on PCB.
51
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
In order to record a synchro signal for rudder angle and wind direction and an analog signal for wind speed on
VDR/S-VDR, the NAV-Interface unit (NAV-I/F: NCT-52A option) must be connected to the VDR/S-VDR. Set up the
NAV-I/F following the procedure described hereunder.
1) Each channel
Check the check box of connected CH as follows.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
Check box
Select the setup CH
1) Selecting CH
Click the radio button for setting sensor channel.
2) Click the [Detail] button on sensor section and the detail setting window appears.
52
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Select the option unit (NCT-52A) and recording data according to the following procedure.
The initial value for receiving the data of the option unit (NCT-52A) is set up automatically on the detail setting
window.
53
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
● NAV-I/F
Set an identification data of NCT-52A.
1) Equipment
"NAV-I/F" is entered automatically.
2) Model
"NCT-52A" is entered automatically.
3) Manufacturer
"JRC" is entered automatically.
● CH1
Set an information data of rudder angle output equipment.
1) Contents
"Rudder" is entered automatically. It cannot be modified.
* Synchro signal for rudder angle has to be connected to the CH1 of NCT-52A.
2) Equipment
Enter the name of the connected equipment.
3) Model
Enter the model name of the connected equipment.
54
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4) Manufacturer
Enter the name of the manufacturer of the connected equipment.
5) Serial No.
Enter the serial number of the connected equipment.
* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial
No. column.
● CH2
Set an information data of wind direction output equipment.
1) Contents
"Wind Direction" is entered automatically. It cannot be modified.
* Synchro signal for wind direction has to be connected to the CH2 of NCT-52A.
● CH3
Set an information data of wind speed output equipment.
1) Contents
"Wind Speed" is entered automatically. It cannot be modified.
* Analog signal (1-5V or 4-20mA) for wind speed has to be connected to the CH3 of NCT-52A.
55
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
"Rudder angle", "wind direction", and "wind speed" data from NCT-52A are displayed on real time.
Verify the converted value after all setup.
When the converted value is not correct, retry a setup of parameters.
56
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
● Rudder Setting
Set the parameters for converting Synchro signal to rudder angle data.
Step 1) Control the actual rudder, so that the rudder angle value is set to "00.0."
Step 2) Select ratio from x2, x3, x4 or x5.
Step 3) Click the [Initialize] button.
Wait for 5 seconds until initializing of NCT-52A is completed.
Step 4) Click the [Adjust] button.
Step 5) Verify that the correct rudder angle value is displayed on the “Check value”.
● NAV-I/F data
The setup parameters to NCT-52A are displayed.
57
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Step 1) Control the anemometer to stabilize the value of the wind direction.
Step 2) Select direction from Order or Reverse.
Step 3) Click the [Initialize] button.
Wait for 5 seconds until initializing of NCT-52A is completed.
Step 4) Input a wind direction value displayed on the anemometer.
Step 5) Click the [Adjust] button.
Step 6) Verify that the correct wind direction value is displayed on the “Check value”.
● NAV-I/F data
The setup parameters to NCT-52A are displayed.
58
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
● NAV-I/F data
The setup parameters to NCT-52A are displayed.
The NMEA sentence can be monitored by the real time monitor on the setting screen.
● Sentence format
$ANADATA, “Rudder angle data”, “Wind direction data”, “Wind speed data”……
59
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3) Converting value
Verify that the converting value is correct.
Enter the diagnostic result to radio button (Good/No Good).
4) Comment
Enter a comment if the result is NG.
60
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Enable / Disable of Radar connection and the FGB can be set up.
1) Each channel
Check the check box of “Sub” in case of connected two Radars.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
• S-VDR (JCY-1850)
FGB is an option board in the S-VDR.
Therefore the default setting of FGB is “disable”.
When the FGB is installed into the RCU, Check the check box of “FGB”
• VDR (JCY-1800)
・ VDR(JCY-1800)
FGB is a standard board in the VDR.
Therefore the default setting of FGB is “enable” and the check cannot be cancelled.
Click the [Detail] button on Radar section then the detail setup window appears.
61
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Model
Enter the model name of the connected equipment.
2) Manufacturer
Enter the name of the manufacturer of the connected equipment.
3) Serial No.
Enter the serial number of the connected equipment.
* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial
No. column.
62
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
● Radar model
Cap2-JMA9900-1800.txt
Cap2 "2" means this setup file is for FGB: CKA -137.
Reference:
When “Cap” is not suffixed by 2 (i.e; Cap-..), the setup file is for CKA-129.
JMA9900 Radar model
1800 “1800” means the setup file is for JCY-1800/1850.
Reference: “1700” stands for JCY-1700/S.
● VESA
Cap2-1024x768-60Hz-1800.txt
Cap2 "2" means this setup file is for FGB: CKA -137.
Reference:
When “Cap” is not suffixed by 2 (i.e; Cap-..), the setup file is for CKA-129.
1024x768 Image Resolution
60Hz Refresh rate
1800 “1800” means the setup file is for JCY-1800/1850.
Reference: “1700” stands for JCY-1700/S.
This is the recording mode applied when two radars are hooked up to the VDR/S-VDR.
The Radar Interface Unit should be installed, when the display resolution of connected Radar unit is UXGA.
*Caution: The Radar interface unit has a cooling fan. In case “None” is selected, Fan alarm is not informed even
when the alarm arises.
63
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
When two radars are connected and VDR/S-VDR records one of the two radar images by switching, set the switching
signal.
1) Dry contact
Select “Dry contact”, when recording channel is switched by dry contact signals outputted from a switcher.
2) NMEA
Select “NMEA”, when recording channel is switched by the PJRC sentence outputted from JRC radar.
3) None (Auto)
Select “None”, when the switching signal is not connected.
Recording channel is switched by detecting a RGB signal.
When radar images are sent from both radars, the image on CH1 is recorded.
4.7.3.2.2. NMEA
Sensor channel which receives PJRC sentence for switching is set up automatically.
Verify that a Radar connection channel is displayed.
PI_1
PI_2
64
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2) Starting to monitor
START: Click the [Start] button.
STOP: Click the [Stop] button.
3) Diagnosis
Have a look the radar picture and judge the quality by yourself.
Then click the [Image Quality check] button. Sort the acceptable or better picture to “Good” and the questionable
or worse to “No Good”.
65
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
* Click the [Help] button to have an advice on judging the Image quality.
* When a location gap of recording image exists or the focus of recording image is poor, adjust the value of
the configuration file of the FGB referring to Chapter 11.
1) Entry lamp
Error in setting entry (Model, Serial number, etc.) is warned by the “Entry” lamp.
66
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
• Transmit
Click the [SET] button.
• Cancel
Click the [Close] button.
As for the diagnosis of the [Radar] section, the result is indicated by the "Diagnosis" lamp.
* Setting of modified data of the "Radar" section is validated after the reboot
of RCU.
Therefore, when a setup data is changed, do not refer to the diagnostic result
made before rebooting the RCU.
1) FGB
The Ethernet communication link condition of the Frame Grabber Board
(FGB) and the Main Control Board (MCB)
2) Main
The RGB signal from the main radar
3) Sub
The RGB signal from the sub radar
67
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Each channel
Click the check box of connected CH as follows.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
Check box
Click the [Detail] button on Microphone section then the detail setup window appears.
68
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Type
Select an indoor type or a waterproof type.
2) Place
Enter the location where the microphone is installed.
3) Serial No.
Enter the serial number of the Microphone unit.
• Serial number: XXXXnnn
4) Model
Enter the model name of the connected Microphone.
[Default setting data]
Indoor type: NVT-161
Waterproof type: NVT-162
69
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Monitors the real time audio of Microphones that is recorded in the VDR/S-VDR to check the operation.
Caution: Audio data is a mixture of triple input from each Microphone. For checking that each Microphone is
correctly working, connects only one Microphone to monitor.
2) Starting monitor
START: Click the [Play] button.
STOP: Click the [Stop] button.
3) Volume
Adjust the sound volume by a slide bar.
Caution: When sound does not come out from the loudspeaker, check whether or not the speaker output of PC is
OFF or sound volume is minimum.
4) Diagnosis
Listen to the audio and judge the quality by yourself.
Click the [Audio Quality check] button.
Judge the audio quality on microphone 1-3, 4-6 and 7-9 respectively.
Click “Good” or “No Good” accordingly.
If the latter is the case, write a comment.
* Click the [Help] button to have an advice on judging the Audio quality.
70
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Entry lamp
Error in setting entry (Model, Serial number, etc.) is warned by the “Entry” lamp.
• Transmit
Click the [SET] button.
• Cancel
Click the [Close] button.
71
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
As for the diagnosis of the [Microphone] section, the result is indicated by the "Diagnosis"
lamp.
* Setting of modified data of the " Microphone " section is validated after the
reboot of RCU.
Therefore, when a setup data is changed, do not refer to the diagnostic result
made before rebooting the RCU.
1) MIC1-9
The result of Microphone test
2) ARB
The operating state of data I/F of the Audio Recording Board (ARB) and the Main
Control Board (MCB)
72
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Each channel
Check the check box of connected CH as follows.
y Enable: [9] (checked)
y Disable: [ ] (unchecked)
73
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Model
Enter the model name of the connected equipment.
2) Manufacturer
Enter the name of the manufacturer of the connected equipment.
3) Serial No.
Enter the serial number of the connected equipment.
* If the equipment is old, the serial number may not be labeled on. In that case, enter "unknown" in the Serial
No. column.
4) Place
Please select the equipment place of VHF from the pull-down menu.
Monitors the real time audio of VHF transceivers that is recorded in the VDR/S-VDR to check the operation.
Caution: Audio data is a mixture of triple input from each VHF transceiver. For checking that each VHF
transceiver is correctly working, connects only one VHF transceiver to monitor.
1) Starting monitor
START: Click the [Play] button.
STOP: Click the [Stop] button.
2) Volume
Adjust sound volume by a slide bar.
Caution: When sound does not come out from the loudspeaker, check whether or not the speaker output of PC is
OFF or sound volume is minimum.
4) Diagnosis
Listen to the audio and judge the quality by yourself.
Click the [Audio Quality check] button.
* Click the [Help] button to have an advice on judging the Audio quality.
74
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Entry lamp
Error in setting entry (Model, Serial number, etc.) is warned by the “Entry” lamp.
• Transmit
Click the [SET] button.
• Cancel
Click the [Close] button.
As for the diagnosis of the [VHF] section, the result is indicated by the "Diagnosis" lamp.
* Setting of modified data of the "VHF" section is validated after the reboot of RCU.
Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU.
1) ARB
The operating state of data I/F of the Audio Recording Board (ARB) and the Main Control Board (MCB)
75
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
VDR/S-VDR
76
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4.10.2.1.1.Ship’s Identification
4.10.2.1.2.Q’ty
77
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Initial
The “Initial” means the setup in the JRC Mitaka factory.
The maintainer name, company name, and the date & time (UTC) are automatically registered.
2) Amendment
The “Amendment” means the setup on board.
The maintainer name, company name, and the date & time (UTC) are automatically registered.
78
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4.10.2.3.1. Battery
4.10.2.3.2. FAN
The expiry date of the two cooling fans in the PSU of RCU is displayed.
Enter the new expiry date of the cooling fans, when you exchange two cooling fans.
The life of cooling fans is four years.
If the expiry date is approaching (i.e. the fans has to be replaced within a year), the message “REPLACE FAN
BEFORE: Year/Month” flickers red as an alarm
79
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Serial No.
Enter the serial number of the capsule.
2) Next Replacement
The expiry date of the battery in the beacon of capsule is displayed.
Enter the new expiry date of the battery in the beacon, when you exchange the beacon unit.
The expiry date of the battery is indicated on the beacon label.
If the expiry date is approaching (i.e. the battery has to be replaced within a year), the message “REPLACE
BEACON BEFORE: Year/Month” flickers red as an alarm
4.10.2.3.4.Blackout test
2) Result of diagnosis
A result is displayed on the “Test result” lamp.
80
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4.10.2.4.2.Maintenance number
The Maintenance number (an intrinsic firmware number of the circuit board) of each unit (PCB) is displayed.
Report all the Maintenance number for repairing.
81
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
82
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Check the check box of the “NSK (CH33, 34)” when a Heading data or ship’s speed data is recorded via NSK in
VDR/S-VDR.
1) Setting
• VDR: The NSK-I/F board is an option board. Click “NSK” box when installing the NSK-I/F board
newly into the RCU.
• S-VDR: The NSK-I/F board is a standard component. The box has already been checked as default.
2) System window
When the “NSK (CH33, 34)” is checked, NSK section is displayed in the System window.
1) Setting
• COM: Check the check box of the COM.
* Caution
Set up this function after setting up the option unit connection.
(Refer to 4.5.)
83
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
When additionally installing RMB into S-VDR, set it according to the following steps.
Note) For more detailed setting method, refer to the installation guide accompanied to the RMB kit (NZK-1850).
1) Setup operation
・RMB : Check the checkbox of RMB
・[Apply] button: Click [Apply] button.
The configuration data required for adding RMB is sent, and then S-VDR reboots
automatically.
*Note
If RMB add-on setting is mistakenly done, uncheck the checkbox of RMB and click
[Apply] button.
The configuration data without the RMB installation is sent, and S-VDR restores the
condition before adding RMB.
84
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
General dry contact signals can be inputted, and they can be recorded as NMEA sentence data. The number of dry
contacts must be three or less. Set up the respective sentence according as the dry contact is on or off.
Caution: The dry contact signals for switching Radars and switching GPSs are connected to these input ports.
When the ports are occupied by the switching signals, these ports cannot be used for general dry contact
signal entries.
4.10.2.7.2.Setup
1) Enable/Disable
Enable / Disable of each PI port connection can be set up.
Check the check box of the connected port.
85
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Entry lamp
Error in setting entry is warned by the “Entry” lamp.
• Transmit
Click the [SET] button.
• Cancel
Click the [Close] button.
* Setting of modified data of the "VDR" section is validated after the reboot of RCU.
Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU.
86
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Model
Select a model name from the pull down menu.
The option model means a capsule of large storage capacity (3Gbyte).
Two Radar images can be recorded at a time when this option is selected.
2) Serial No.
Enter the serial number of the connected equipment.
87
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Entry lamp
Error in setting entry is warned by the “Entry” lamp.
• Transmit
Click the [SET] button.
• Cancel
Click the [Close] button.
* Setting of modified data of the "Capsule" section is validated after the reboot of RCU.
Therefore, when a setup data is changed, do not refer to the diagnostic result made before rebooting the RCU.
88
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
89
DOC No. 7ZPNA4013D
4. Installation, Setup, and Operation Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
90
DOC No. 7ZPNA4013D
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
5. SYSTEM Screen
On the SYSTEM screen, the connection setup, the operating state of VDR/S-VDR system and the condition (Good/No
Good) of received signal can be verified.
● Enable / Disable of each connection channel and the setup of connection interface
● Detail setting of each connection channel
● Reference to and registration of information of detail setup VDR/S-VDR
● Warning to wrong entry of setting
● Display of the receiving state (OK/NG) of each serial channel
● Display of the state (OK/NG) of VDR/S-VDR operation: Radar, Microphone, VHF, Capsule
● Display of the System status information of each section: Radar, Microphone, VHF, Capsule
91
DOC No. 7ZPNA4013D
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Here, how to operate the common buttons on the SYSTEM screen is described.
1) [Receive] button
The Maintenance software receives the system configuration data of RCU
Click the [Receive] button, progress of data reception is displayed on the progress bar placed at the bottom of the
screen. The display of system screen will be updated by the received system configuration data.
2) [Diagnosis] button
Diagnosis function is engaged by this button.
Click the [Diagnosis] button then diagnosis function starts and the button burns green.
3) [Set] button
This button is used to set up each system configuration data.
Click the [Set] button then all the configuration data is transmitted to the RCU.
* The button registers the system configuration data of each section in the “detail setup” window to RCU. It is
unnecessary to use the [Set] button on the System screen when the detail window is opened to revise the setup data.
Use the [Set] button on the System screen when all the system configuration data should be revised or only the
individual check is changed.
4) [Reboot] button
The button triggers to reboot the RCU.
Click the [Reboot] button then the RCU will be restarted by renewed system configuration.
Wait until the communication link of Maintenance software and RCU will be reestablished.
92
DOC No. 7ZPNA4013D
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
7) [ACK] button
The [ACK] button on this screen works in the same way as the [ACK] button on the OPU.
The [ACK] button is used to silence the ALARM BUZZER.
In case multiple errors arose, presses the button as many times as the errors were raised.
Change of display
93
DOC No. 7ZPNA4013D
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Blinks in red
Blinks in red
Caution: Even when the [Reboot] button blinks red, it is not necessary to click the button immediately.
When all the setup is completed, reboot the RCU, and check the operation of the VDR/S-VDR.
94
DOC No. 7ZPNA4013D
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Diagnostic items
Section The Software diagnosed on;
Sensor Recording (receiving) the sentence or not.
VDR CF Card, expiry date of battery, replacement date of FAN, Initial error and so on.
Radar Radar image
Communication link of FGB and MCB: normal / abnormal
Recording radar image: receiving the RGB signal / not receiving
Quality of Radar image: judgment by service engineer
Microphone Microphone audio
MIC test result: OK / NG
Control of ARB by MCB: normal / abnormal
Quality of microphone audio: judgment by service engineer
VHF VHF audio
Quality of VHF audio: judgment by service engineer
Capsule Capsule
Communication link of Capsule and RCU: normal / abnormal
BER of Capsule: within the limit / beyond the limit
95
DOC No. 7ZPNA4013D
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
* System status window is available at VDR, Radar, Microphone, VHF, Capsule sections.
* “Sensor section” does not have the window because error information can be browsed at each detail setting
menu.
1) Selection
Click a section name (e.g. Radar) positioned upper left.
96
DOC No. 7ZPNA4013D
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3) Sensor section
Click [Sensor] positioned upper left of the sensor section.
The recording sentence ID list appears.
97
DOC No. 7ZPNA4013D
5. SYSTEM Screen
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Home Press the button to return to the HOME screen for selecting a work item 3.1
The connection, setup, and monitoring the operation of VDR/S-VDR system are
System 4.1
available.
Playback Press the button to playback and check the recorded data in Capsule or in CF card. 10
Press the button then the Maintenance software disconnects the link with RCU.
Logout 2.2
The Maintenance software comes to an end.
98
DOC No. 7ZPNA4013D
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
6. EVENT Monitor
Monitors the operation event of VDR/S-VDR to check that VDR/S-VDR system is working correctly.
The EVENT monitor can display the received EVENT data from the VDR/S-VDR.
Additionally, the EVENT monitor can display EVENT Log files in the VDR/S-VDR.
6.1. Starting
4) RCU reboots
When the RCU is restarted by the [Reboot] button on the "SYSTEM" screen with the Event monitor turned on, the Event
monitor can display the event data after starting of the RCU.
Reboot the RCU for checking event data from starting of the RCU.
99
DOC No. 7ZPNA4013D
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
100
DOC No. 7ZPNA4013D
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
To have an access the old event data, download the event log files from the RCU.
Event data from the very first operation of VDR/S-VDR are there.
There are the Event log files that have been recorded on CF card by RCU.
3) Older event data until the last real time monitor turning on is added to the event list.
101
DOC No. 7ZPNA4013D
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2) The sorted out event data list is displayed on a newly opened Window.
All category name buttons are now not selectable.
3) To change the EVENT category, close the present display Window of Extract EVENT.
All category name buttons return to selectable.
102
DOC No. 7ZPNA4013D
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2) An event that plunges in during the sort is practiced is Not sorted, but is placed at the top of the list as the latest event.
1) On the View menu, point to Language, and then click either English or Japanese.
103
DOC No. 7ZPNA4013D
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The EVENT log file recorded by the RCU and the file saved by the EVENT monitor can be opened.
The files are:
• The saved event log files in the CF card
• The event log files downloaded from the capsule
• The event log files saved by the Event monitor
1) Opening a file
Point to “Open” on the “File” menu. Then the File dialog appears.
2) Selecting a file
Select “writefile.txt” on the folder where Event log is saved.
The following event data displayed now on the EVENT monitor can be saved as a file.
• “evt” file:
Recognized by “Event monitor” only.
1) Saving a file
Select “Save” or “CSV Save” on the “File” menu.
• Save: Saves “evt” file
•CSV Save: Saves “csv” file
104
DOC No. 7ZPNA4013D
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Record start
Click the [Record Start] button.
Select a save folder on the File menu. The start time of recording equals the file name.
Then [Record Start] changes to [Record Stop].
2)Recording file
The record file is saved on the desktop.
3)Record stop
Click the [Record Stop] button.
Then [Record Stop] changes to [Record Start].
105
DOC No. 7ZPNA4013D
6. EVENT Monitor
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
106
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Although NMEA data, image data and audio data can be monitored at each Detail window in the SYSTEM screen, another
real time monitor is available on the Monitor menu.
● Starting
Each real time monitor can be started from the menu directly.
Use these real time monitors for checking the received data only apart from setups.
7.1. Starting
1) Menu
Click the Monitor menu.
107
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Monitors the NMEA sentence data, and checks whether or not the sentence specified by the installation drawings is
collected correctly.
If the specification of the laptop PC is relatively low, single channel monitoring is recommended. Incase two
or more channel are monitored at a time, CPU load rises to 100%, and operation may stop.
When the software freezes, press <Alt>+<Ctrl>+ <Delete> then Windows Task Manager will appear.
Terminate the maintenance software there.
108
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
● “RCV data”: Monitors all the receiving data from the selected channel.
The sentence data which is not recorded by the VDR/S-VDR is also displayed.
● “REC data”: Monitors the sentence data which is recorded by the VDR/S-VDR only.
The sentence which is not recorded is not displayed even when it is received.
Monitors the data currently set in the VDR/S-VDR.
2) Monitor stop
Click the [STOP] button.
The Gray light returns.
● “REC data”
The addition and deletion of the CH to the monitor can be operated freely.
● “RCV data”
Capable of single channel monitoring only. In case multi channels are monitored on “RCV data”, a
mixture of received data is indicated.
2) Restart
The [Pause] button changes to the [PLAY] button during the pausing. Click the [PLAY] button to restart.
109
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2) Save start
Click the [SAVE START] button.
The sentence data which is monitored now is saved in the text file.
3) Save stop
The [SAVE START] button changes to the [SAVE STOP] button during the saving.
Click the [SAVE STOP] button to stop saving.
7.2.6. Quit
1) Abide by the following procedure to quit monitoring. Otherwise an error arises.
Stop all of the monitoring channels.
Before quitting the maintenance software, please make sure that the real time monitor has been stopped.
Reboot RCU, if the maintenance software has been quitted without stopping the real time monitor to stop
outputting the real time data.
110
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Play button
Stop button
Volume
For each connected unit (MIC1,2,3,4,5,6,7,8,9, VHF1,2,3), connect only one unit to check the operation.
→ Each monitor CH receives a mixture of 3 input signals. To verify that each unit is correctly working, it is
necessary to connect only one unit to the monitor.
2) Monitor stop
Click the [Stop] button to stop monitoring.
The monitored sound is played about four second later than the sound source.
7.3.4. Quit
Click the [×] button on the upper right of the window after monitor stop.
111
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
7.4.1. Operation
No need to operate since the monitor functions of itself.
The image that the VDR/S-VDR is recording is displayed.
The image is updated every 15 seconds as well as the image record.
The monitored image is displayed a few seconds later than the record time.
112
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
113
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The present position is displayed by a green lamp on "Engine telegraph position", "Sub-telegraph position", and
"Operating location"
.
When the [Back] button is clicked, an engine telegraph window will be closed and returns to the dry contact state
window.
114
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
115
DOC No. 7ZPNA4013D
7. Real Time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
116
DOC No. 7ZPNA4013D
8. System Status Display
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
8.1. Starting
Click the “System Status” from the “System” pull down menu.
117
DOC No. 7ZPNA4013D
8. System Status Display
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
118
DOC No. 7ZPNA4013D
8. System Status Display
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Capsule
The “Capsule” section of the “Record Control” window
2) Microphone test
The “Audio” section of the “Record Control” window
119
DOC No. 7ZPNA4013D
8. System Status Display
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
*1 The old Maintenance software (Version 1.2.0) save the system configuration file named “McbDataInfo.dat”.
8.5.2. File
Open the system configuration file (VdrDataInfo.dat).
On the “File” menu point to “Open” and click.
120
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9. Functions of Menu
This chapter explains the auxiliary functions that can be executed from Menu.
Regarding the function explained in another chapter as main function, the chapter and/or section number is shown in
the “Refer to;” column. The arrow (►) means the function that is detailed in this chapter 9.
Card Download Download the latest sensor data file and Radar image file recorded in ►
CF card.
Help Error Code List Shows meanings of Error code displayed on the OPU ►
(English)
Error Code List
(Japanese)
Software Version Shows the software version of Maintenance software ►
121
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9.2. Control
The VDR/S-VDR can be controlled by the Maintenance software.
9.2.1. Starting
Click the “Control” on menu.
* This [MCB] button functions in the same way as the [Reboot] button.
122
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
* Following FGB-related functions have FGB maintenance mode started automatically therefore it is not necessary
to turn on the FGB maintenance mode again.
• FGB setup
• FGB utility
• FGB update
* Caution: Radar image can not be recorded during the FGB maintenance mode.
Be sure to stop this mode, before diving in FGB maintenance mode.
5) When the unit is rebooted, the entered date and time is set firm.
Confirm the date and time after rebooting.
123
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
When the update of the program ended in failure and the software freezes with the function status remaining
"Download", “Request Unit Mode” shifts the status back to “Normal”.
If the [Cancel] button has no effect on shifting the function status back to “Normal” mode, there is something
wrong with the equipment.
124
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9.3. Converting the Recorded data to general files (.txt .png .wav)
The recorded data saved in the CF card or downloaded from the capsule can be converted to general files which are
opened by standard application software on PC.
1) Open the "Data" pull-down menu of the System screen, and click the [Convert] button.
Source Folder
Selection button
Convert Folder
Selection button
[Convert] button
125
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
・In order to convert downloaded data from VDR/S-VDR, select folders or files which are enclosed by the dashed
line.
xxxxx¥YYYYMMDDhhmmss¥Playlist*
|
|―― ¥VDR
|
|―― ¥Init
|―― ¥Log
|―― ¥Audio
|―― ¥Visual
・In order to convert recorded data of the CF card, select folders or files which were enclosed by the dashed line.
CF card drive
|
|―― ¥Init
|―― ¥Log
|―― ¥Audio
|―― ¥Visual
2) Converting
Click the [Convert] button. Then conversion of files starts.
When conversion starts, conversion status is indicated by progress bar.
And converted files are indicated in the list box.
[Convert] button
126
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
127
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
YYMMDD: Date
hhmmss: Time (UTC)
????????: IMO No. (If IMO number is not entered, automatically converts to “99999999”.)
128
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
A setup file of each unit (MCB, FGB, etc.) can be sorted out from a “SysInfo.dat” file saved in the CF card or the
capsule.
9.4.1. Starting
1) Click the "Config" from the "Data" pull down menu on the system screen.
2) Saving a file
Select a save folder, and input the file name.
129
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The latest sensor data file and Radar image file recorded in CF card can be downloaded. The software, however,
does not correspond to download of an audio file.
1)Click “Card Download” by opening the pull-down menu of “Data” on System screen.
2)Select the file desired to be downloaded, and then click [Download] button.
Since the Radar image file is converted to PNG format after being downloaded, the file can be checked by opening
it immediately after that.
130
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Accesses to the error code displayed on OPU and the recommended remedy.
9.6.1. Starting
1) Click the "Error Code List" from the "Help" pull down menu on the system screen.
The content, the cause, and the correspondence method of the error code are displayed at the right of the screen.
131
DOC No. 7ZPNA4013D
9. Functions of Menu
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
9.7.1. Starting
1) Click the “Software Version” from “Help” menu.
132
DOC No. 7ZPNA4013D
10. Playback
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
10. Playback
Verify that the installation and the setup have been finished successfully and the VDR/S-VDR works satisfactory by
playing back the data of the capsule and the CF card.
10.1. Starting
133
DOC No. 7ZPNA4013D
10. Playback
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The recorded data of VDR/S-VDR are saved on the Capsule and the CF card.
Do not forget to playback and check both of them.
1) Capsule
The recorded data is downloaded from the Capsule to the maintenance PC via LAN.
2) CF card
The recorded data is copied from the CF card to the maintenance PC with a card adaptor.
Check the recorded data of both the capsule and the CF card at the end of installation.
134
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
“FGB_Utility” software is useful for setting up and tuning the Frame Grabber Board CKA-129/CKA-137. The setup menu
has Board setup function with the aid of capture setup file and other file. The tuning menu allows maintainer to tune sync
polarity, horizontal/vertical synchronization and sampling phase.
135
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
a) Click the .
To tune the channel 2, click the . In case “Ch2.txt NG” message appears, align the capture setting using [Ch 2
capture setting] menu, referring to the next section.
Immediately after the click, the following message appears. This message appears only on the first connection to the
board.
c) "Changed to channel 1" message appears at the left bottom corner of the window.
136
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Measured value
Sync Activity ch 1
Sync Activity ch 2
V sync polarity
H sync polarity
V sync frequency
H sync frequency:
Total line number
Setup value
V sync polarity
H sync polarity
c) Check that the Radar image format measured by CKA-137 is the same as that of the Rader specifications.
Resolution (estimated value):
Vertical synchronous signal frequency (Refresh rate):
Horizontal synchronous signal frequency:
Vertical synchronous signal polarity:
Horizontal synchronous signal polarity:
If the “Sync Activity” column is inactive, most probably synchronous signal could not be detected by the board. Verify
the wiring, signal output and input channel.
137
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
c) Click the capture setting file. File name is formatted as shown bellow.
JRC Radar setting: Cap2-"Radar model name"-1800.txt
| |
| CKA-137 board installed in JCY-1800/1850
ex. JMA9900
138
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
139
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
11.3. Tuning
Measured value
Setup value
140
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The click reverses the H sync polarity and captures the image. Then the following message appears.
g) Have a look on the [ADC status] menu, and check that the measured H sync polarity is the same as that of the setup.
Regarding the V sync polarity, follow the same procedure using [V Sync polarity reverse] menu.
141
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
d) Click the horizontal edge of the image. Don’t care the Y coordinates.
142
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
e) To practice horizontal position tuning at this point, click [Yes]. Or to retry the image shift, click [No] and tweeze
the horizontal edge of the image.
After successful horizontal position shift and image capture, the result message appears.
c) To have the image moved left, click the [Yes] button. To have the image moved right, click [No]. To finish the
tuning, click the [Cancel] button.
After successful horizontal position shift and image capture, the result message appears.
143
DOC No. 7ZPNA4013D
11. Frame Grabber Board (CKA-137) Setup - FGB Utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
If the captured image is out of focus, tune the sampling phase to achieve the best sharpness. Normally, go to Phase
AUTO tuning. A phase AUTO tuning is practiced on still image, stop the transmission of Radar.
144
DOC No. 7ZPNA4013D
12. “OPTION” System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
MCB and RMB software Ver2.0.1 or later is capable of distributing the real-time data simultaneously by the
multicast output setup as well as the conventional unicast distribution that specifies an output destination.
First, check MCB and RMB software version, and then set it up as necessary.
12.1. Starting
145
DOC No. 7ZPNA4013D
12. “OPTION” System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The setup operation of multicast is the same as that of the conventional real-time monitor except entering the
IP address for simultaneous distribution.
12.4. IP Address
12.4.1. For Real Time Monitor
The VDR/S-VDR outputs the real time data to the specified IP address.
To change the IP address, open a Network window by clicking the [Edit] button.
1) VDR-WAN port
Designate the IP address of VDR-WAN port on RCU which
is connected to the option PC.
Default: 192.168.0.254
2) Option PC
Designate the IP address of the monitor PC.
Default: 192.168.0.251
146
DOC No. 7ZPNA4013D
12. “OPTION” System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Default: 192.168.0.253
1) EXT LAN
Check the checkbox of “EXT LAN”.
2)Address
Enter a multicast address.
Default: 239.0.112.1
3)Port
Enter a port number.
Default: 6501
Reception side should also set up the same multicast address and port number as what was set up above.
147
DOC No. 7ZPNA4013D
12. “OPTION” System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Normally, as all the data are required by the real-time monitor, all the boxes of connected channels are checked as
default.
1) Sensor section
Only the connected CH can be set up. Do not setup the channels of unchecked boxes.
Check each channel that should output a NMEA data.
The NMEA sentence data are outputted from the checked channels.
2) Audio
Check “AUDIO” box for outputting an audio monitor data.
3) FGB1
Check “FGB1” box for outputting an image monitor data from the VDR/S-VDR.
4) FGB2
The current maintenance software does not support the setup.
Do not check the checkbox.
148
DOC No. 7ZPNA4013D
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
13. Report
When the installation is completed, create a set of report files using this function.
13.1. Starting
149
DOC No. 7ZPNA4013D
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
13.1.1. Report
Setup data, diagnosis, check result and so on can be confirmed in the Report screen.
And all the contents are saved to files as service report.
Since the Report files are registered in the Ship List of the Marine Service Department Home Page, send the files to
the Marine Service E-mail address with the following subject.
150
DOC No. 7ZPNA4013D
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
151
DOC No. 7ZPNA4013D
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Operation
1) Select any one from 4 Search selections in the Tab Selection.
2) Tab select button which is searched blinks red.
3) Click the tab select button which blinks red.
Tab screen can be selected by click tab directly also.
4) Searched item is indicated by red.
In order to cancel error, measure in accordance with above table.
152
DOC No. 7ZPNA4013D
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Saved files:
• Report file
• MCB system configuration file
• RMB system configuration file *1
• MCB system status file
• RMB system status file *1
• FGB setup file *1
• DSC setup file *1
• Event log file
• Radar image file *1
• Sensor data file
*1: In case of non-connection, the files are not saved.
Save the report file by [Save] button. If necessary, the report file can be renamed and saved.
If the report is saved, save folder, file name and creation date is indicated.
153
DOC No. 7ZPNA4013D
13. Report
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Click the [Open] button, and select report folder in the Open screen, select a report file.
Contents of selected report file are indicated.
If necessary, the opened report file can be and corrected.
Because diagnosis is started automatically in the report screen, latest Diagnosis results are updated into the opened
report file.
Save folder, file name and creation date of opened file are indicated.
154
DOC No. 7ZPNA4013D
14. Program update
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
155
DOC No. 7ZPNA4013D
14. Program update
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
2) Version check
Check the version of the present program.
Click the [Version] button and the present version is shown.
If it is the latest, program update is not needed.
The RCU is restarted automatically and operated with the renewed program after the updating has been completed.
It is not necessary to reconfigure the system following the update.
156
DOC No. 7ZPNA4013D
14. Program update
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Internet Explorer (IE) starts and the root menu of the FGB WEB screen is displayed.
157
DOC No. 7ZPNA4013D
14. Program update
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3) Click the [renew] button on the FGB WEB root menu of the IE.
158
DOC No. 7ZPNA4013D
14. Program update
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Software Version
2) Update software version saved in the maintenance software is displayed on the “Capsule Update"dialog.
If the version is out of date, select the latest version by clicking the [Browse] button. After the select update
software version is displayed, click the [Yes] button to proceed.
Note)
159
DOC No. 7ZPNA4013D
14. Program update
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4) Confirm current software version by clicking the [Get Current SW Version] button.
Software version
5) Input a “✓” mark beside “Automatic Reboot after update”, and then start update process by clicking [Update
Software] button.
“✓”
Updating status
160
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
15.1. How to play back the downloaded data from the Capsule via Ethernet
[DOWNLOAD] button
161
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
③ Select a save place with the aid of Folder selection button, and then select a playlist.
Once download starts, playlists (from playlist1 to playlist10) are created automatically under the save place.
Saving maximum 9 download data is possible under the playlist folder except playlist1.
Playlist
Note) Download data size can be specified in every 1 % with slide bar.
⑤ Check the box of necessary download data and click the [Start] button.
Please press [OK] button, click [Cancel] button of the download software, and end the download software.
162
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
OK
【Note】Folder Composition
Save Place (Save Folder)
Save Folder(Created by the folder name registered on the input screen ((5) section).)
Playlist1
Playlist2
VDR Init
Log
Audio
Visual
Event
Playlist3
Playlist10
[PLAYBACK] button
② Click the [SETUP] button on the “PLAYBACK” launcher menu, and start the Setup software.
[SETUP] button
163
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
③ The Login screen appears. Click the [OK] button after confirming that “User” has been clicked in the Operator
block.
User
④ To import VDR/S-VDR configuration data, select the following file in the download data and click the [Import]
button.
*: ¥Playlist2¥VDR¥Init¥SysInfo.dat
Download folder
⑤ Click the [Folder Selection] button, and select the folder created in accordance with the “3.1.3 Download data
from VDR/S-VDR by Download software”.
164
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
[PLAYBACK] button
2) Click the [PPLAYBACK] button on the “PLAYBACK” launcher menu, and start the Playback software.
[PLAYBACK] button
165
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Playback time span of the Slide bar can be selected by the Slide bar select button.
・12hours: 12 hours
・All: All the periods of record data
【Note】
In case of downloading from the Capsule, the record data period might be for a few days.
Playback time span of the Slide bar becomes long, and so it is not easy to adjust playback time.
In that case, select the 12 hours in the Slide bar select button.
Playback time span becomes 12 hours; moreover, scale in every hour is displayed.
So it is easy to adjust playback time.
166
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
In order to play back record data of CF card, it is necessary to create a playback folder in the computer of in advance,
and to copy the data.
③ Start the Playback software, and copy the record data of CF card.
15.2.2. Set required information for playback with the Setup software
1) Click the [PLAYBACK] button on the “VDR INVESTIGATIVE SOFTWARE” launcher menu.
[PLAYBACK] button
2) Click the [SETIP] button on the “PLAYBACK” launcher menu, and start the Setup software.
[SETUP] button
167
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3) As the Login screen appears, click the [OK] button after confirming that “User” has been clicked in the Operator
block.
User
4) Eject a CF card from the VDR/S-VDR, and insert to the card slot of another laptop PC.
Then, to import VDR/S-VDR configuration data, select the following file in the CF card and click the [Import]
button.
Note: Which drive is for CF card depends on the PC model.
D: ¥Init¥SysInfo.dat
5) Click the [Folder Selection] button, and select a folder created in accordance with the “3.1 Create a playback
folder”.
168
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
[PLAYBACK] button
2) Click the [PLAYBACK] button on the PLAYBACK launcher menu., start the Playback software
[PLAYBACK] button
169
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
5) Verify whether or not the CF card drive is set in the Copy source.
If not, click the [Folder Select] button to select the drive.
6) Select a playlist in the Copy place and copying data volume in the Size and then click the [Copy] button.
Copying volume can be selected from 1hour to 12 hours or all.
If 1hour is selected, 1 hour data from the latest is copied.
7) Check playlist2-Playlist10 where CF card data have been copied, then click the [OK] button.
170
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Click the [Setup] button located at the bottom right in the playback screen and the Setup screen appears.
[Setup] button
2) Click the [Exit] button located bottom left in the Setup screen.
[Exit] button
171
DOC No. 7ZPNA4013D
15. Playback Software Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
172
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
16.1. Log in
Select the RMS, and then click the [Next] button. The HOME screen of RMS appears.
Select the RMS, and then click the [Next] button. The HOME screen of RMS appears.
173
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Click the [Installation] button, and then the System screen for setup appears.
174
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
175
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
The basic remote maintenance function can be set up by the following procedure.
Only VDR and S-VDR with built-in RMB can collect and preserve the maintenance data from JRC equipment.
The S-VDR without built-in RMB can only diagnose itself by the remote access connection.
2) Connection setup of the JRC equipment connected to VDR (For VDR/S-VDR with built-in RMB only)
Check the checkbox of RMS connection channels.
Usually, setup is completed only by checking.
3) Connection setup of the JRC equipment newly connected for RMS (For VDR/S-VDR with built-in RMB only)
Check the checkbox of channels to additionally register the connection setup of the JRC equipment connected for
RMS.
Click the [Detail] button, and then the detail setup window appears.
Enter the identification data and interface data of connecting equipment like setup for VDR.
The sentence ID of maintenance sentence (PJRC) is inputted automatically.
1) Identification screen
Set up identification data of connected equipment.
176
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
• Comment
Enter helpful information for maintaining.
The entry of a comment is not mandatory.
Enter the identification data and interface data of connecting equipment like setup for VDR.
The sentence ID of maintenance sentence (PJRC) is inputted automatically.
2) Data screen
Set up serial interface and sentence ID of maintenance sentence.
177
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Identification screen
This screen is same as screen for serial connection.
2) Data screen
Set up the LAN interface.
• IP address
Set up the IP address of equipment which output a maintenance sentence.
(IP address: 192.168.60.xxx)
IP address table
178
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
•VDR: 192.168.0.254
•INM: 192.168.0.1
2) Link test
Click the [Start] button, and then the lamp lights in green or red as a result of test.
● (Green): Result of test is good.
● (Red): Result of test is not good.
z If the [Diagnosis] button is clicked during the diagnosis function is on, the function will be
stopped.
179
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
This section introduces the remote maintenance data download and viewer screens.
For detailed instruction, refer to Remote Maintenance Installation Manual of separate volume.
180
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1)Connected equipment information 2)Reception lamp 3)Alarm lamp 4)Selecting download data
5)[Download] button
6)Viewer screen start button
Latest data Log data Received data
2)Reception lamp
When PJRC sentence (maintenance data) is being received in specified interval time, the Reception lamp indicates
green. If not, it indicates red.
3)Alarm lamp
When the relevant equipment is operating normally, the Alarm lamp indicates green. If it is generating the error, the
lamp indicates red.
→ Acquire (Download) maintenance data of the equipment with error indication, and then analyze the root cause.
* Speed Log(JLN-205/550): The Alarm lamp always shows in orange since it utilizes special sentence.
181
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
5)[Download] button
The download of specified maintenance data starts by clicking the [Download] button.
Downloaded data can be saved as a file and displayed.
2)Package selection
When downloading all maintenance data, all checkboxes can be checked together at the same time.
・ Select “All Check” from “View” menu.
・ As the following checkboxes display in the right side of screen, check the checkbox of necessary data
classification.
3)Download
Click the [Download] button to start downloading the maintenance data.
182
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
・Click the [Data Form] button to display the file selection dialog.
・As conversion file list displays, select a conversion file for the equipment concerned from the list.
183
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
● Converted data display (Code→Text) ● Text data display (displays received data)
184
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
● Received date & time(UTC) ● Ship’s position at the time of reception (Lat / Lon)
New
Old
185
DOC No. 7ZPNA4013D
16. Remote Maintenance System Setup
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
186
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
17. Installation
Here the installation procedure of the maintenance software for JCY-1800 / 1850 is described.
If the old version has already been installed, make the old version by way of the “Control Panel” – “Add/remove
Programs” of Windows.
Allow
187
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
1) Perform “setup.exe”
Double-click the”setup.exe” file.
2) Start installer
When the [Next >] button appears, click it after displaying the following window.
188
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4) Installation folder
As default, “Program Files¥JRC¥JCY1800¥Maintenance” is specified as the installation folder.
Click the [Next >] button.
5) Start installation
Click the [Install] button to start the installation.
189
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Tera Term
Hyper Terminal has been discontinued in Windows Vista.
When the VDR IF (router) of VDR real time monitor is set up, Use the Tera Term instead of Hyper Terminal.
9) Select "I accept the agreement", and click the [Next>] button.
190
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
191
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
192
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
17)When Windows Vista PC is used, it is necessary to continue and to cancel UAC (user account control).
Cancel it according to the following operations.
・Select Properties.
Properties
Compatibility tab
193
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
・Input a "✓" mark in "Run this program as an administrator" of "Privileged level", and click the [OK] button.
Privileged level
Allow
194
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
●For Windows XP
1) Click the "Date, Time, Language, and Regional Options" on the Control Panel screen.
195
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3)Select the "Regional Options" tab, select the "English (United States)" or the "English (United Kingdom)".
Advance tab
196
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
197
DOC No. 7ZPNA4013D
17. Installation
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
3) Select the "Formats" tab, select the "English(United States)" or the "English(United Kingdom)",
Format tab
Administrator tab
198
DOC No. 7ZPNA4013D