LOCATION AT SITE SIZE SERIES HOT/COLD LOAD(KG)

D.COMER ECONOMISER INLET(RIGHT /SUGAR) 11 VS-2


D.COMER ECONOMISER INLET(LEFT/BAGASSE) 11 VS-2
D.COMER(REAR/RIGHT/WATER WALLS) 13SPL VS-3
D.COMER(REAR/LEFT /WATER WALLS) 13SPL VS-3
D.COMER(REAR/RIGHT/WATER WALLS) 9SPL VS-2
D.COMER(REAR/LEFT /WATER WALLS) 9SPL VS-2
D.COMER(REAR/RIGHT/DRAG-CHAIN FLOOR) 11 VS-3
11 VS-3
D.COMER(REAR/LEFT /DRAG-CHAIN FLOOR) 11 VS-3
11 VS-3
D.COMER(RIGHT/DRAG-CHAIN FLOOR) 10 VS-3
D.COMER (LEFT / DRAG-CHAIN FLOOR) 10 VS-3
D.COMER(RIGHT) 28 VS-3
28 VS-3
D.COMER(LEFT) 28 VS-3
28 VS-3
D.COMER(RIGHT/FRONT) 10SPL VS-3
D.COMER(LEFT /FRONT) 10SPL VS-3
MS LINE (NBC FLOOR) 682
MS LINE (CSDH FLOOR) 2740
MS LINE (OUT TG FLOOR) 488
488
MS LINE (INSIDE TG FLOOR) 13 VS-3
18 VS-2
SPRING DATA(12-12-2018)

HOT/OPERATING LOAD(KG) COLD/PRESET LOAD(KG) HOT L. POS.SET COLD L. POS.SET


829 644.17 35 10
829 644.17 35 10
1057 907.75 90 60
1057 907.75 80 60
1426 1053.25 75 40
1426 1053.25 60 40
849 643.63 0* 55
849 643.63 0* 55
849 643.63 0* 90
849 643.63 100 65
672 559.06 90 55
672 559.06 90 55
2034 2034 - 70
2034 2034 - *
2034 2034 - 50
2034 2034 - 60
690 641.03 140 70
690 641.03 - *
40 10
50 13
32 10
32 10
983 1018 85 95
3345 3096 45 35
POINTER READING(MM) TRAVEL(MM) SPRING RATE(KG/MM) TYPE
80(100) -30.805 6B
85(100) -30.805 6B
75(180) -38.073 3.92 F
60(180) -38.073 3.92 F
75(100) -41.083 9F
65(100) -41.083 9F
100(180) -68.456 3B
120(180) -68.456 3B
130(180) -68.456 3B
100(180) -68.456 3B
60(180) -17.057 2.4 B
75(180) -17.057 2.4 B
80(180) -10.287 F
* -10.287 F
65(180) -10.287 F
70(180) -10.287 F
110(180) -62.068 2.4 F
* -62.068 2.4 F
25(50) -106.71 F
13(70) -116.62 CONSTANT SUPPORT
20(50) -61.266 CONSTANT SUPPORT
20(50) -61.266 CONSTANT SUPPORT
105(200) 8.596 F
25(100) -8.589 B2
CONCLUSION
pointer reading is more than hot load by 45mm.
pointer reading is more than hot load by 50mm.
pointer reading is between cold & hot load.
pointer reading is at cold load.
pointer reading is at hot load.
pointer reading is more than hot load by 5mm.
100-55=45mm<68.456mm
120-55=65mm<68.458mm
130-90=40mm<68.456mm
100-65=35<68.456mm
pointer reading is between cold and hot load.
pointer reading is between cold & hot load.
80-70=10mm<10.287mm
no scale on site.
65-50=15mm>10.287mm
70-60=10mm<10.287mm
pointer reading is between cold & hot load.
no scale on site.
pointer reading is between cold & hot load.
pointer reading is between cold & hot load.
pointer reading is between cold & hot load.
pointer reading is between cold & hot load.
pointer reading is more than hot load by 20mm.
pointer reading is below cold load.