Professional Documents
Culture Documents
Rexroth 4we10 Data Sheet PDF
Rexroth 4we10 Data Sheet PDF
99
RA 23 351/09.99
Replaces: 06.98, 08.90
Nominal size 10
Series 3X
Maximum operating pressure 4569 PSI (315 bar)
HA 5960/98
Maximum flow 31.7 GPM (120 L/min)
Contents Features
Description Page – Direct solenoid operated spool type directional control valve
Features 1 – With “5th chamber” for dampened adjustable spool shifting
Ordering code 2, 3 time
Symbols 3 – Mounts on standard ISO 4401-5, NFPA/ANSI T3.5.1 M R1 D 05,
Functional description, section 4, 5 ANSI B 93.7 D 05 interface
Technical data 6 – For subplates, see data sheet RA 45 054
Characteristic curves 7 – Wet pin DC solenoids (AC possible with rectifier)
Performance limits 7 – Removable coils for quick replacement, or conversion, in AC or DC
voltages
Unit dimensions 8
– Individual solenoid plug-in connectors, or central wiring box to
Available spare parts and seals 9
NEMA 4 specifications (see data sheet RA 08 002)
– Optional manual overrides
– 53 standard spool configurations available
Important!
The length of the mounting bolt in series 3X/... is 1-1/2"
(40 mm) [formerly 2" ( 50 mm)]
1/10
RA 23 351/09.99
Ordering code
1 2 3 4 6 7 9 10 11 12 15 18 19 22 23
5– WE 10 3X C *
3 actuator ports =3
4 actuator ports =4
Nominal size 10 = 10
Symbol e.g. C, E, EA, EB etc. – for possible versions, see page 3
Series 30 to 39 = 3X
(30 to 39: unchanged installation and connection dimensions)
With spring return = No code
Without spring return with detent = OF
Without spring return =O
Wet pin solenoid (oil immersed) with removable coil =C
12 V DC = G12
24 V DC = G24
96 V DC = G96 1)
For further ordering details regarding other voltages and frequencies, see page 6.
With protected manual override (standard) = N9
Without hand override = No code
Hand override with protective cap =N
Model of electrical connection
Individual connection; with component plug = K4 2)
DIN 43 650-AM2, without plug-in connector
Without switching time adjustment = No code
With adjustable screw (throttle) =C
Orifice Ø 0.0236 in (0.6 mm) = A06
Orifice Ø 0.0276 in (0.7 mm) = A07
Orifice Ø 0.0315 in (0.8 mm) = A08
Without cartridge throttle = No code
Throttle Ø 0.0315 in (0.8 mm) = B08
Throttle Ø 0.0394 in (1.0 mm) = B10
Throttle Ø 0.0472 in (1.2 mm) = B12
Throttle Ø 0.0591 in (1.5 mm) Used for flows > performance limits of = B15
Throttle Ø 0.118 in (3.0 mm) the valve, effective in the P channel = B30
NBR seals = No code
FKM seals =V
(other seals on request)
Attention!
The compatibility of the seals and pressure fluid has to be taken into account!
Further details in clear text
For further
plug-in connectors
see RA 08 006
Material no.
With indicator light and
Valve With indicator light With LED & rectifier With rectifier Z diode protective circuit
side Color Without circuitry 12 … 240 V 24 … 240 V 12 … 240 V 24 V Thread
a grey RR00 074683 – – – – Pg 11
b black RR00 074684 – – – – Pg 11
a/b black – RR00 057292 RR00 057423 RR00 313933 RR00 310995 Pg 11
a red/brown RR00 004823 – – – – 1/2“ NPT
b black RR00 011039 – – – – 1/2“ NPT
a/b black – RR00 057453 RR00 057455 RR00 842566 – 1/2“ NPT
Symbols
A B A B A B A B 1)
b b
Example:
a b a b a 0 b a 0 b
a
a
P T P T P T P T
Spool E with switched position “a”
A B
a b
A B A B Ordering detail ..EA..
a b …/O.. a 0 a 0 = .A 1)
P T a
P T P T
a b A B A B
a b …/OF.. b
0 b 0 b
= .B
P T P T
=A
= E 1) =P
=C
=F =Q
=D
=G =R
A B A B
b
a b a b
a
P T P T =H =T
=B
=J =U
=Y
=L =V
=M =W
2 7 1 3 5 2
A B
"a" "b"
TA T P B TB
4 4 6
Model 5-4WE 10 E3X/CG24N9K4/C..
"a"
TA
Detent
General
Installation optional
Max. ambient temperature °F (°C) 122 (50)
Weight Valve with 1 solenoid lbs (kg) 10.4 (4.7)
Valve with 2 solenoids lbs (kg) 13.9 (6.3)
Hydraulic data
Max. operating pressure Ports A, B, P PSI (bar) 4569 (315)
Port T PSI (bar) 3046 (210) with symbols A and B, port T must be used as
drain port, if the operating pressure is higher
than the permissible tank pressure.
Max. flow GPM (L/min) 31.7 (120)
Flow cross-section For symbol V in2 (mm2) 0.0171 (11) (A/B → T); 0.016 (10.3) (P → A/B)
(switched position 0) For symbol W in2 (mm2) 0.0039 (2.5) (A/B → T)
For symbol Q in2 (mm2) 0.0085 (5.5) (A/B → T)
Pressure fluid Mineral oil (HL, HLP) to DIN 51 524 1);
Fast bio-degradable pressure fluids to
VDMA 24 568 (also see RA 90 221); HETG (rape seed oil) 1);
HEPG (Polyglycols) 2); HEES (synthetic ester) 2);
other pressure fluids on request
Pressure fluid temperature range °F (°C) –22 to +176 (–30 to +80) (with NBR seals)
–4 to +176 (–20 to +80) (with FPM seals)
Viscosity range SUS (mm2/s) 35 to 2318 (2.8 to 500)
Degree of contamination Maximum permissible degree of contamination of the pressure
fluid is to NAS 1638 class 9. We, therefore, recommend a filter
with a minimum retention rate of ß10 ≥ 75.
Electrical data
Model of voltage DC
Available voltages 3) V 12, 24, 42, 60, 96, 110, 180, 205, 230
Voltage tolerance (nominal voltage) % ±10
Power consumption W 35
Duty continuous
Switching time to ISO 6403 ON ms 45 to 70
(without switching time adjustment) OFF ms 35 to 45
Switching frequency cycles/h 15000
Protection to DIN 40 050 IP 65
Insulation class VDE 0580 F
Max. coil temperature 4) °F (°C) 302 (150)
1)suitable for NBR and FPM seals
2)only suitable for FPM seals When connecting the electrics, the protective conductor
3) special voltages on request
(PE ) must be connected according to the relevant
4) Due to the surface temperatures which occur on the solenoid regulations.
coils, the European standards EN563 and EN982 must be taken
into account!
D, Y 2 2 1 3
(12) 174 6 E 2 2 3 4
(11) 160 F 2 1 4 7
(10) 145 5
4
G 4 4 6 8
(9) 131 H 2 2 1 3
(8) 116 3
1 J, L 1 1 4 4
(7) 102
2 M 2 2 3 4
(6) 87
P 2 1 1 7
(5) 72.5
Q, V 1 1 3 4
(4) 58
R 1 4 3 –
(3) 43.5
T 4 4 5 7
(2) 29
(1) 14.5
U 1 1 3 3
W 1 1 3 5
0 2.64 5.28 7.93 10.6 13.2 15.9 18.5 21.1 23.8 26.4 29.1 31.7 Switch. pos. B–A
0 R – 9 – –
(10) (20) (30) (40) (50) (60) (70) (80) (90) (100) (110) (120)
Centr. pos. B–T A–T P–T
Flow in GPM (L/min) F – – 4 4
G, T – – – 8
P – 8 – 6
Performance limits: DC, measured at ν = 190 SUS (41 mm2/s) and t = 122 °F (50 °C)
Because of silting, the shifting function of the valves is dependent upon If only one direction of flow is required, for example, when a 4-way valve has
filtration. To obtain the maximum flow values shown, full filtration of 25 µm one port plugged, or with unbalanced flows from large rod cylinders, the
is recommended. The flow forces acting within the valve also influence permissible flow in critical cases can be considerably lower. The A or B spool
performance. In 4-way valves, the data provided is for applications with 2 (3-way) can be used as an approximation of the limited flow performance.
directions of flow (flow from P to A and an equal, simultaneous return from Performance limits measured with solenoids at operating temp-
B to T), (see table). erature, 10% undervoltage and without tank port pressure.
(315) 4569
Operating pressure in PSI (bar)
(300) 4351
4
Char. curve Symbols
3
(250) 3626
2 With orifice Ø 0.0236 in (0.6 mm) („A06“)
12
(200) 2901
10 3 D, Y
5 12 C
(150) 2176
12 1 With and without orifice
(100) 1450
1 C/O, C/OF, D/O, D/OF, M
(50) 725 2 A/O, A/OF, E, J, L, U, Q, W
4 G
0 2.64 5.28 7.93 10.6 13.2 15.9 18.5 21.1 23.8 26.4 29.1 31.7
0
5 F, P
(10) (20) (30) (40) (50) (60) (70) (80) (90) (100) (110) (120) 10 H
Flow in GPM (L/min)
(315) 4569
Operating pressure in PSI (bar)
(300) 4351 1
11 7
(250) 3626 Char. curve Symbols
6 Without orifice
(200) 2901
9 1 D, Y
8
(150) 2176 6 C
(100) 1450
7 R
8 T
(50) 725
9
9 V
2.64 5.28 7.93 10.6 13.2 15.9 18.5 21.1 23.8 26.4 29.1 31.7
11 A, B
0
0
(10) (20) (30) (40) (50) (60) (70) (80) (90) (100) (110) (120)
Flow in GPM (L/min)
5-.WE 10 7/10 Rexroth Hydraulics
RA 23 351/09.99
Unit dimensions: dimensions in inches (millimeters)
0.0004/4.0 in
11 17 3.63 (92.2)
0.01/100 mm
2.13 (54) 0.752 (19.1) 32
(Rmax 4)
0.591 (15)
10 5 8 4 16 15 13 4 9 10
0.591 (15)
Ø 0.433 (11)
0.236 (6)
A B
Pg 11 6
4.61 (117)
4.84 (123)
3.62 (92)
1.58 (40)
1.18 (30)
12
13 7 2 1 3 7
1 3-position valve 1) 11 Manual override “N9” (standard) 16 Porting pattern to ISO 4401-5, NFPA
2 2-position valve – Actuation of the manual override is only T3.5.1M R1 and ANSI B 93.7 D 05
with 1 solenoid (A, C, D, EA...) 1) possible up to a max. tank pressure of Subplates
725 PSI (50 bar) – Avoid damage to the G 66/05 (3/8" NPT);
3 2-position valve
manual override pin bore! G 66/12 (SAE-6; 9/16-18);
with 1 solenoid (B, Y, EB...) 1)
12 Dim. for manual override “N” G 67/05 (1/2" NPT);
4 Plug for valve with 1 solenoid G 646/12 (SAE-10; 7/8-14);
13 Name plate
5 Solenoid "a" (plug-in connector colour G 534/05 (3/4" NPT);
grey) 14 R-ring 0.512 in x 0.063 in x 0.079 in (13 G 534/12 (SAE-12; 1-1/16-12)
mm x 1.6 mm x 2 mm (for valve with
6 Solenoid "b" (plug-in connector colour 17 Valve Mounting Bolts
throttle insert:
black) 4) 1/4 - 20 UNC x 1-1/2" (M6 x 40 mm)
O-ring 0.472 in x 0.079 in (12 mm x 2
7 Space required to remove the coil socket head cap screws
mm)
8 Plug-in connector without circuitry to (SAE grade 8 or better)
15 Additional T port (TB) may optionally be Tightening torque 11.4 lb-ft (15.5 Nm)
DIN 43 650 2) (Z4, Z45) used in conjunction with drilled blocks. Subplate and valve mounting bolts must
9 Plug-in connector with circuitry to be ordered separately, see RA 45 054
DIN 43 650 2) (Z5, Z55) 1) Dimension without manual override and
10 Space required to remove plug-in with protected manual override “N9”
connector 2) must be ordered separately, see page 3.
113
113
160
113 157