FLASH REPORT

PROJECT : BSP BF#4


DOCUMENT NO. : FR-04-POIN001818

PURCHASER : Danieli Corus India Pvt. Ltd.


CONTACT AT DC : Sohan Kashyap, Quality & Inspection
SUPPLIER : M/s Uttam Sucrotech,Ghaziabad
LOCATION OF INSPECTION : M/s Uttam Sucrotech,Ghaziabad
INSPECTION DATE : 23/02/2018
ISSUE DATE : 26/02/2018
INSPECTOR : Sohan Kashyap
NOTIFICATION NOI- 09 Dt 26.02.2018
NUMBER :

INSPECTION DESCRIPTION
Blow Pipe with Cating Tip for Stage Inspection as below

Sr. Description Total QTY as Remarks


No. per Drg

01 RT-Film review (Lower elbow) 24 Nos

02 RT-Film review (Reducing elbow) 24 Nos

03 RT-Film review (Blow elbow) 4 Nos

REFERENCE DOCUMENTS:

Sr. No. Description Revision Status


1. DRAWINGS:P003510-362BH19-005-MG1520 1 RAF
P003510-362BH19-005-MG1420 0
P003510-362BH19-005-MG1320 0

2. DCI-TSA-ITP REV 00 0 RAF

Observation:-

RT of Below mentioned items to be taken again due to less density and required sensitivity was not in acceptable
range
a. LE-10 and LE-13 to 24
b. BP-01 to 04
c. RE-08
Below mentioned parts are to repair & reshoot

RE-13 & RE-09

Pending:

-Technician level 1 or 2 certificate


-Level II certificate for Mr. Anil Prasad singh
-ASTM-IQI certificate not submitted
-BARC licence copy
-Source certificate/Camera holding certificate
-Focal spot size
-Correct information of SOD and Exposure time to be mentioned in report.
-Level III Approved procedure

Page 1 of 2
FLASH REPORT

PROJECT : BSP BF#4


DOCUMENT NO. : FR-04-POIN001818

NCR ISSUED
Yes No
NCR No:
REMARKS:

In case no submission of above documents NCR will be


generated and further inspection activity may stop.
PARTICIPANTS (NAME, FUNCTION, LOCATION, DATE, SIGNATURE)

CLIENT : Bhilai Steel Plant


:
DANIELI CORUS Sohan Kashyap , 26/02/2018

SUPPLIER : Ashu , 26/02/2018 ( M/S UTTAM )