DUPLEX2017 RCColDes

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Column Reinforcement Design Calc.

By:
Rev: 1 Checked By:

Column Reinforcement Design


1C1 (A1-1) (200/250) (C25/30 / Grade 460 (Type 2))
NTop M1 Top M2 Top NBot M1 Bot M2 Bot
No
(kN) (kN.m) (kN.m) (kN) (kN.m) (kN.m)
1 67.3 2.2 -1.9 72.3 -1.0 1.2
2 78.2 2.3 -1.6 83.3 -1.1 1.1
3 29.4 1.1 -1.5 34.5 -0.4 0.9
4 51.1 -1.2 -1.6 55.5 2.5 1.0
5 61.0 4.9 -1.7 65.3 -4.1 1.0
6 66.0 1.9 -5.9 70.3 -0.9 5.7
7 46.2 1.7 2.6 50.5 -0.7 -3.7

Critical Loading: 1 - (G+Q *F)


Min Design
N 72.3 - 72.3 kN
M1 2.2 0.7 3.6 kN.m
M2 -1.9 -0.9 0.0 kN.m
Nmax 756.1
Concrete Cover = 25.0 mm
BS8110-Cl.3.8.4.5
N/bhFcu = 0.048
Beta = 0.94

Vd(1/2) = 3.0 / 3.9 kN Short Column... As (Req): %0.40 (min) 200.00 mm2
vc'(1/2) = 0.77 / 0.75 N/mm 2 Le1/b1 = 9.7 < 15.0 ✔ As (Sup): %0.90 452.39 mm2
v(1/2) = 0.06 / 0.08 N/mm 2 Le2/b2 = 7.7 < 15.0 ✔
Madd(1/2) = 0.0 / 0.0 kN.m 4T12
Links = R8-125

ProtaStructure v2.0.6 Page 1