AALLAN real Arrive Ppoint allowed angle AANGXZ real Angle of attached SCTN in XZ plane of joint AANGYZ real Angle of attached SCTN in YZ plane of joint ABLE integer Minimum abbreviation length for a UDA/UDET user defined name ABOP pos Bottom of arrive pipe ABOR real Arrive bore ABRE string(8) Abbreviation ACBO string(1000) Actual bore ACCDIR dir Access Direction ACCELE real(500) Elevations of Referenced Levels ACCESSDB string(10) DB access ACCIDENT real Accident level radiation ACCLEV real(500) Access Heights for Stairwell ACCREF element Reference to Access element ACCTYP word Access type ACDATE string(50) Date last modified in AutoCAD ACDSTY string(120) AutoCAD Dimension style ACDWT string(120) AutoCAD drawing template name ACEXPO string AutoCAD export flag ACLASS word(100) Access Control Attribute class ACLAYE string(120) AutoCAD layer name ACLIST element(500) Arriving cables to attached point ACLOCK string AutoCAD picture lock ACNAME string(120) AutoCAD name ACON word Arrive connection type ACORRO real Arrive corrosion allowance ACPICT string AutoCAD picture flag ACPO element Access port reference ACRF element ACR reference attribute ACRGRP element(5000) List of ACRs within a ACRSET ACRLI element(1000) Access Control User assigned ACRs ACRMESSAGE string(120) Access Control User defined message ACSCAL real AutoCAD picture scale factor ACSTYF element Annotation change style reference ACTANG real Actual angle of a bend ACTL real Actual length ACTNCU integer Actual number of cuts of a bend ACTRAD real Actual radius of a bend ACTTYPE word Type of element, truncating non UDETs to 4 or 6 characters ADDSEGMENTS logical Auto creating segments flag ADEFRF element Reference to master ASSDEF ADEG real Orientation ADEN real Addition factor (unit definition) ADESP real(100) Design parameters of attached element ADIR dir Arrive direction ADMLOC element Currently administered location ADPRFA element(500) ADP reference array ADUUID string(40) PDMS Project GLOBAL UUID version string AELRFA element(500) Boundary components for the PipePiece AGRD real Arrive Ppoint gradient AHLIS word(200) List of actual types in owning hierarchy AIRCHA real Air Change Rate AIRT string(120) Air tight control method AKEY word Attribute key AKEYL word(20) Attribute-keylist (for Radial dimensions) ALCODE integer(10) Alarm code array ALENGTH real Arrive length ALIGN string Vertical alignment ALIST element(500) ALLANG string(1000) Connection allowable rotational angle ALLELE element(10000) elemtype All elements in the MDB of a particular type ALLO real Allowance ALTDEF element Alternative Def AMAPNM string(120) Local Name of Proxy actual member AMEMRF element Reference to a design model object AMPMPN string(120) Local Name of Proxy in Association ANGFR real Angle between assembly and frame plane ANGL real Angle ANGLSP real(10000) ANGLE Spacing ANGSPA real Springback angle at 20 degrees ANGSPB real Springback angle at 120 degrees ANGWL real Angle between assembly and water-line plane ANPJ pos Attached neutral point of joint (steelwork) ANPS pos Attached neutral point of section (steelwork) ANSTYP word Type of answer NONE, REAL, WORD, TEXT or BOOL ANSW real Answer, when a real is expected ANTY string(120) Analysis type ANYCHA logical True if chamfer is defined on any edge AOBJS element(500) Reference Array of all Model currently participating in ASSOCs AOD real Arrive Ppoint outside diameter APAR real(100) Attached catalogue parameters APARMS real(9) All parameters APDT string(12) Date of approval APOF real(2) Leaderline attachment point APOS pos Arrive position APOSE real Easting of arrive position APOSN real Northing of arrive position APOSU real Upping of arrive position APPL string(20) Application APPR string(1000) Approver APRO real Spot value of property A AQAANG real Angle between alignment direction of arrive pp and previous AQANG real Angle between arrive Ppoint and previous component AQBORE logical TRUE if arrive Ppoint has same bore as previous AQCON logical TRUE if arrive Ppoint has Correct connection type AQOFF real Offset between arrive Ppoint and previous component AREA integer Area AREAEX logical True if area exists for DB AREARE element Area reference ARNO integer Picture directory area number ARRHEI real Arrive height ARRI integer Arrive Ppoint ARRWID real Arrive width ASBPAN element Assembly base panel reference ASBUIL string(1000) Assembly build strategy ASCODE string Anno selection code ASDEST string(120) Assembly destination ASECOG real(3) Assembly estimated centre of gravity ASEWEI real Assembly estimated weight ASIOWN element(500) Assembly item referring to element ASIQUA integer Assembly item quantity ASLSBSTANDARD element ASL Substandard Reference ASLSTANDARD element ASL Standard Reference ASMBLD logical True if element is assembled ASMBLR element Assembly reference ASMBLS string A for assembled elements, NA for not assembled elements ASMBLX string(120) Assembly reference as text ASMBS element(500) Reference Array of all association members using element ASMOWN element(500) Assembly referring to element ASNAME string(50) Local assembly name ASORI integer Predefined assembly orientation ASORIS string(20) Predefined assembly orientation string ASPART logical True if assembly part. ASPLNO integer Number of assembly plate parts ASPRNO integer Number of profiles on assembly part ASPWLE integer Total length of weld in assembly part ASREF element Assembly reference ASRF element ADP annotation symbol library ref ASSCIA element(500) Reference Array of all associate elements used with constraints ASSDFS element(500) Reference Array of all ASSDEFs ASSEQ integer Assembly sequence ASSNTS element Reference to assembly nest (valid for individual nest only) ASSOS element(500) Reference Array of all associations with constraints ASSTAR element Association Target Reference ASSTMPREFERENCE element Assembly Template Reference ASTAB word(15) ADP association table ASTMBS element(500) Reference Array of all association members targeting element ASUB real Angle subtended ASWLOC string(120) Assembly working location ATCONN element(500) List of elements connected to attachment ATCORR real Arrive tube corrosion allowance ATEX string(1000) Unintelligent text string ATLE real Length of arrive implied tube ATLS word(50) Access type list ATNA word Attribute name ATOL integer Arc tolerance ATOP pos Top of arrive pipe ATQUALIFIER string(4000) Attribute qualifier ATTC word Attached connection type ATTDST word(2000) List the distributed attributes, default gives all udas ATTLIST word(2000) List of all attributes for element ATTMOD logical attr True if specified attribute has been modified this session ATTMODC logical attr True if specified attribute has been modified since comparison date ATTMODLIST word(500) integer List of attributes modified since given session ATTMODLISTC word(500) List of attributes modified since comparison date ATTNAM string(32) Attribute Name expression for ATTRRL elements ATTOUT word(2000) List of all attributes excluding hidden ones, i.e as output in "Q ATT" ATTRAW word(2000) List of raw attributes ATTRUL string(1000) Attribute Rule expression for ATTRRL elements ATTSET word Set attribute with result ATTY word Attachment type ATWALL real Arrive tube wall thickness ATWLEN real Assembly total weld length ATWREF element Arrive tube wall thickness reference AUTCOL real(3) Design rgb autocolour AUTCRE logical Set true to automatically create bound element. AUTH string(1000) Author AVRAD real Average radius for a CTOR or RTOR AWALLT real Arrive wall thickness AWDARR logical Auto weld arrive flange AWDFLN logical Bending machine accepts autowelded flanges AWDLEV logical Auto weld leave flange AWDOWN integer(3) Table linking AWELD elements to piping components AWDREF element(20) Return reference to AWELD element AWELDS integer(20) Weld numbers of attached welds AXIDIR dir Axis direction applied to repeat AXIPOS pos Axis position applied to repeat AXSPRI logical Is principle Axes Symbol AXSSIZ real AXESYM nominal size AXSTYP word Axes Symbol type AYDIR dir Arrive Y axis direction AZDIR dir Arrive alignment direction AZID real Default Azimuth value AZIF real Azimuth attractor factor AZIL real(2) Azimuth limits (Min/Max) AZIS logical Azimuth set flag - ignore Azimuth values if FALSE BAEXSS real Bending Excess Arrive BAIN string Before/After indicator BANG real Beta angle BASETYPE word Base type for the user- defined element type BBFF element(500) Array of bounding Boundary Formers BCPY element Backward copy reference BDIA string(1000) Bolt diameter BEAD real Default Bearing value BEAF real Bearing attractor factor BEAL real(2) Bearing limits (Min/Max) BEAS logical Bearing set flag - ignore Bearing values if FALSE BELRFA element(500) All components in the PipePiece BELTYP integer(500) All component types in the PipeSpool BENDCORNERS logical Bend corners - true if fillet should be applied to the corners of kickplate BENDMACREFERENCE element Bending Machine reference BENDMC element Bending Machine Reference BENT logical Bent flag BEVCOD real(10) Bevel codes for edges BEVEL real Bevel BEVFLA real Bevel code, flange BEVLEN real(2) Lengths of bevel BEVLFT real Bevel code on left side of seam BEVLI real(3) Lengths of I-bevel BEVLV real Length of vertical bevel BEVLX real(3) Lengths of X-bevel BEVLY real(3) Lengths of Y-bevel BEVM real(2) Bevel codes along M1 and M2 curves BEVRGT real Bevel code on right side of seam BEVTXT string Bevel text BEVWEB real Bevel code, web BFCOLO integer Backface colour BFCONU integer Backface colour number BFLE string(1000) Out of plane flexibility factor for bends BFPN integer Backface pen BFRF element Reference to real Boundary Former BFSTREF element Backface linestyle Reference BFSTYL integer Backface linestyle BITE word(25) Bolt items BITL real(25) Bolt item lengths BJOINT string Bolt joint BKEY string(4) DRAFT user defined base symbol/skey name BLCKLM logical True if block limit seam BLEN real(200) Bolt length BLEXSS real Bending Leave Excess BLNK logical Auto-blanking flag BLRF element(10) Bolt reference array BLSLEN real Length of blasting contours BLTM string(3) Bolt method BLTR element Bolt reference BMAR real Auto-blanking margin BMAX integer Maximum bend number in current spool drawing BMCLOC logical True if bending machine bends clockwise BMLEVE real(100) Beam levels from owning element BNDARE real Boundary line area BNDOFF real Offset from boundary BOLTPARTNUMBERS integer(20) Spooling bolt part numbers BORE real Bore BOREAR real(10) Bore array BPANOR ori Curved base panel orientation BPANRE element Base panel reference BPOF real(4) Leader bend point offset BPRO real Spot value of property B BRACKE string Brackets code BRAD real Bend radius BRALNK element(20) Connectivity SCBRAN- BRANCH Link BRCOG pos Branch centre of gravity BRCONNECT element(5000) Branch member connections BREARE real Branch external surface area BREF element Branch Reference BRIARE real Branch internal surface area BRICOG pos Branch insulated centre of gravity BRIWEI real Branch insulated weight BRLEG element(5000) Branch members on the same leg BRLO integer Branch Positioning Status code (Router) BRNFAC real Burning factor BRNLEN real Length of burning contours BRNNAM string(26) Burner name BRNNUM integer Burner number BRNPRC string(26) Burner process name BRNREF string(26) Burner reference id BRNSEQ string(26) Burning sequence number BRNST integer Number of starts for burning BRNTOO integer Burner tool BRNTYP string(26) Burner type BRREF element Branch table reference BRTXRF element(500) Return reference from Branch Table element to SPECs BRWCOG pos Branch wet centre of gravity BRWEIG real Branch weight BRWICOG pos Branch wet insulated centre of gravity BRWIWEI real Branch insulated wet weight BRWWEI real Branch wet weight BSCANG real Bend Segment Cut Angle BSCLL real Centre-Line Length of a mitred Bend Segment BSDWG string(120) AutoCAD backing sheet name BSEL string(3) Bolt Selector BSFN string(1024) Backing sheet filename BSLAYE string(120) AutoCAD backing sheet layer BSMNIL real Minimum Length of Insulation of a mitred Bend Segment BSMNL real Minimum Length of a mitred Bend Segment BSMXIL real Maximum Length of Insulation of a mitred Bend Segment BSMXL real Maximum Length of a mitred Bend Segment BSPE element Bolt specification BSRF element Backing sheet reference BSRFA element(500) ADP backing sheet list BSTA integer Branch Status code (Router) BTEX string(1000) Annotation text string BTHK string(1000) Parameterised bolt thickness BTLS word(50) Boundary Former type list BTOL string(1000) Bore tolerance BTOTAL integer Bolt joint total BTYP string(1000) Bolt type BUFS integer Preferred buffer size BUIL logical Built/Unbuilt flag BULG real Bulge factor BUNI word Bore units BUNREF element Cable bundle reference BURF element Reference to real Building Element BURNID string(80) Burner id BUYMARK string(26) Buying mark BVCODN integer Bevelled Code number BVIS logical Bottom visibility flag BVSCLL real Centre-Line Length of a mitred Bend Segment BVSEGN integer Bevelled segment number BVSMNI real Minimum Length of Insulation of a Virtual mitred Bend end- Segment BVSMNL real Minimum Length of a virtual mitred Bend end- Segment BVSMXI real Maximum Length of Insulation of a Virtual mitred Bend end- Segment BVSMXL real Maximum Length of a virtual mitred Bend end- Segment BWITHF logical Bend with flow CABBOX real(6) Calculated box volume in world coordinates CABGAP real cable gap on cabletray as multiple of OUTD CABINT string(120) cable interference class CAGOFF real Cage Offset CAGSIZ real Cage Size CARD integer(2) Cardinality definition CARE string(12) Isodraft Compipe: Area CASR element Case reference CATMOD integer Catalogue Geometry Modified- Not directly query able CATR element Catalogue reference CATTEX string(725) Concatenation of Detailing and Material Texts CATY integer Card type CBACXR real Accumulated cables xarea at route node CBCOG pos Cable centre of gravity CBCULE real Cut Length of cable CBGELE real Geometric Length of cable CBNUCW element(500) Cables at a point on a cableway CBPREF element(500) References to POINTR forming route of a cable CBRNLS element(500) List of route nodes that cable passes CBRWGL real Raw Geometric Length of cable CBSTA integer Cable routing status CBTOLE real Total Length of Cable CBWEIG real Cable weight CCEN integer Cost centre CCLA integer Cost class CCOL integer Colour (in catalogue) CCON word Connection type CCORRE element Cable Core set reference CCORXR element(500) Return reference from CCORSET element to SCOMs CDET element Catalogue detail CDPL word(100) List of valid current design properties CDPR real word Current design dataset property CDRG string(24) Isodraft Compipe: Drawing number CELLID integer(2) Cell Identifier CELLTO real Total Number of Cell CELLTR real Total Number of Trimmed Cells CELLWH real Total Number of Untrimmed Cells CELREF element Status Element reference CEND string Connection at other end of CREF (HEAD or TAIL) CERF element(500) Array of Faces generated by this CEXES real(4) Cable excesses CEXS real Percentage excess for passing cables CFDP element word Current design dataset property CFFA element(500) Array of Faces generated by this CFILL real Fill level at route node CFRA element(10) Cofitting reference array for Pfittings CFRELE real Free Length of cable CHALEN real Length of chamfer intervals CHAM real(2) Chamfer lengths CHANUM integer Number of chamfer intervals CHAR integer Character set CHARGE string(80) Charge CHCOLO integer Crosshairs colour CHCONU integer Crosshairs colour number CHDCOLUMN element Child column CHECKE string(1000) Checker CHEI real Character height CHKDAT string(120) Date checked CHNGD integer Changed counter CHOS real Crosshairs overshoot CHPN integer Crosshairs pen CHSTREF element Crosshairs linestyle Reference CHSTYL integer Crosshairs linestyle CIRCR real(4) Circumscribed rectangle CIWE string(1000) Total insulation weight CKEY word ISODRAFT end condition key CLAI integer Claim mode CLAIMDB string(10) Implicit or explicit claims CLBASE real Column base offset CLCCNT integer Claim list changes count CLCOLO integer Centreline colour CLCONN element(5000) integer Clasher connections CLCONU integer Centreline colour number CLFG logical Centreline flag CLFL logical Centreline flag CLIPCD integer Clip code CLIST element(500) All cables attached to route node CLLE real Branch centreline length CLMID string(120) Unique system ID of user claiming element CLMNUM integer User or extract number claiming element. Extract numbers are negative CLMO string Centreline mode: 1=CL OFF, 2=CL ON CLMTIE element(4) Reference to elements that are automatically claimed along with this element CLNCOD string(120) Ceiling Code CLNELE real Ceiling Elevation CLNFAC real Cleaning factor CLNHEI real Ceiling Height CLNTYP string(120) Ceiling Type CLNVOI real Ceiling Void Height CLOSED logical True if plate covering entire referenced component CLOSEFLAG logical True if branch is closed CLPN integer Centreline pen CLRF element Actual circulation list reference CLRSIZ real(2) Clearance size CLSTREF element Centreline linestyle Reference CLSTYL integer Centreline linestyle CMALL real Structure allowance CMAXF real Calculate maximum fill level on cway CMBOUA element Aft boundary CMBOUF element Fwd boundary CMBOUL element Lower boundary CMBOUP element Ps boundary CMBOUS element Stbd boundary CMBOUU element Upper boundary CMBOX real(6) Bounding box CMCAT string(256) Compartment category CMCDE real Content density CMCTID string(256) Content type ID CMDESC string(256) Compartment description CMFLW real Full Load Weight CMINF real Calculate minimum fill level on cway CMLCV real Longitudinal centre of total volume CMMGE integer Merged compartment indicator CMPER real Compartment permeability CMPERD real Permeability for use in damage CMPLNK element Return reference from schematic or design element to CYMLNK element CMPR element Component reference CMPRFA element(500) All components for the PipePiece CMPSTATUS word Connectivity comparison status CMPSTS string(120) Connectivity comparison status description CMPURP string(256) Purpose CMTCV real Transverse centre of total volume CMTYP integer Type of compartment CMVCV real Vertical centre of total volume CMVOL real Total volume CNTNUM integer Contour number CNUM string(22) Isodraft Compipe: Line number COCDRE element(500) word COCDESS with same COCONN value as qualifier COCONN word COCO Connection type COCORE element(2) COCO description reference COCOXR element(500) COCO description return reference COCSAM element(500) COCOS with same CTYP value as COCDES COLCOL integer Column colour COLCON integer Column colour number COLNUM integer Pin column number COLSCH string(120) Color Schema COLSTREF element Column linestyle Reference COLSTY integer Column linestyle COLXSP real(100) Spacing between columns in the X direction of the tower COLYSP real(100) Spacing between columns in the Y direction of the tower COMBOO word Boolean Combination COMM string(120) Comment COMMST string(500) Comment string COMNT string Comment COMPEN logical Compensate bending activities for springback COMPTYPE word Type of component CONAM string Cutout name CONARR word(10) Connection array CONATS element(500) List of attachment connected to attachment CONBRA element(500) List of branches connected to branch CONCD integer Connection code COND integer(500) Access Control Logical condition CONDES string Connection string CONDGR integer No of Conductor Groups CONNE logical Segment end connection flag CONNECTIONS element(5000) Connections CONNECTIONSH element(5000) Connections for all descendants CONNER string(300) integer Connection error message CONNRE element(10) References to other element CONNS logical Segment start connection flag CONSIS logical Position consistency CONTYP string Connection type COPI integer Number of copies COPYDB element(8191) Copies of this database CORA string(1000) Corrosion thickness CORCGR string(120) integer cable core conductor group CORNUM integer Corner number CORNUV pos Corner point CORROS real Tube corrosion CORRUG logical True if corrugation is defined on the plate part CORTAG string(120) integer cable core tag COUN integer Counter CPAR real(100) Catalogue parameters CPEN integer Pen for internal columns CPFA element(500) Array of Ports this points to CPLO string(120) Plot (in catalogue) CPOF real(2) Leaderline connection point wrt. text origin CPOS pos conditioning position for curve geometry CPRO real Spot value of property C CPUL real(3) Cold pull - translational CPUT real(3) Cold pull - twist CRCANG real Turning angle for least circumscribed rectangle CRCLW real(2) Length and width of circumscribed rectangle CRDATE string(120) attr Date element created in current DB or if extract in ascendant CREANCESTORS logical Create ancestors CREF element Connection reference CREXTR integer attr Extract element created in current DB or if extract in ascendant CRFA element(10) Connection reference array CRINFO string(200) DB creation information CRIT integer(250) Selection criteria (used to define tag & rep. rules) CRSESS integer attr Session element created in current DB or if extract in ascendant CRSF element Change ruleset reference CRUSER string(120) attr User created element in current DB or if extract in ascendant CSESS string(120) integer Comment entered for specified session CSFBR logical Spooling marker for components CSGBOX real(6) CSG-Calculated box volume in world coordinates CSPA real Character spacing factor CSPC string(6) Isodraft Compipe: Specification CSTA string(120) Catalogue Standard CSTR element Constraint reference CTCREF element integer Cable tray component ref CTHICK real Coating thickness CTSPE element Cable tray specification CTTYP word Cable tray typ CTXT string(120) Card text CTYA word Attached connection type CTYE word End connection type CTYO word Owning connection type CTYP word(2) Connection type CTYPLI word(500) List of COCO Ctypes CTYS word Start connection type CURD element(1000) Current DBs CURF string Curve fitting code: 1 default, 2 cubicfit CURLOC element True current location CURREN string(1000) Current CURTYP word Curve type CURVED logical True if curved plate part. CUTB real Cutback CUTL real Cut length CUTNAM string(700) integer Full name of element, truncated to n characters CUTNMN string(700) integer Full name of element (without leading slash) truncated to n characters CUTP dir Cutting plane normal CWEI string(1000) Total component weight CWHEAD element(500) Cableway Head CWHPOS pos Cableway path head point position CWIDTH real Clearance Width CWJUSL word Cable Way Justification Line CWLIST element(500) All cableways attached to route node CWTAIL element(500) Cableway Tail CWTPOS pos Cableway path tail point position D real Position downing DACC string Database access DACCLA logical True if DAC allows element to be claimed DACCOH logical True if DAC allows element hierarchy to be copied to another DB DACCOP logical True if DAC allows element to be copied to another DB DACCRE logical elemtype True if DAC allows element to be created DACDEL logical True if DAC allows element to be deleted DACDRO logical True if DAC allows element to be dropped DACERR string(120) attr Returns the DAC error DACEXH logical True if DAC allows element hierarchy to be exported DACEXP logical True if DAC allows element to be exported DACISS logical True if DAC allows element to be issued DACMOD logical attr True if DAC allows attribute of element to be modified DACOUH logical True if DAC allows element hierarchy to be output DACOUT logical True if DAC allows element to be output DAREF element Reference of associated dataset area DARREF element Design area reference DASSCI element(500) Reference Array of all direct associates with constraints DASSOS element(500) Reference Array of all associations with constraints DATE string(12) Date DATEFO string Date format DATIM string(19) LMI Date/time DATINT integer(2) Date DATONE integer Date 1 DATTWO integer Date 2 DATTXT string(22) Date DBAC string DB Access, MULTIWRITE or UPDATE DBALL element(8000) List of DBs allocated to location DBCL string DB Claim DBCNTL logical True if element is in a control DB DBEXNO integer DB Extract Number DBF element Database reference attribute DBFI string DB filename DBFN integer DB file number DBLC element(1000) List of LOCs belonging to a DB DBLS element(1000) List of DBs belonging to MDB DBNA string DB name DBNU integer DB Number DBOT real Bottom diameter DBPR element(8000) List of DBs Primary at location DBRBEG integer DB range start DBREF element DB reference DBREND integer DB range end DBSESS integer Last DB session DBSHIE element(5000) Database hierarchy within a DBSET DBSLEV element(5000) Databases at a level within a DBSET DBSLIS element(5000) Databases within a DBSET DBSSTP element(8000) DBs in a stamp DBSTF element Database set reference attribute DBTE string DB Text Encoding DBTY word DB type (DESI, CATA etc) DBUsers element(10000) Current Users in the system using this DB DBUSRX element(10000) Current Users in the system using this DB or any extract descendants DBVAR logical True if element is in a variant DB DBVWSTREF element(50) Database View Set reference array DBWRITE logical True if element is in a writable DB DCLA string Database claim mode DCLNCO string(120) Default Ceiling Code DCLNHE real Default Ceiling Height DCLNTY string(120) Default Ceiling Type DCODE string Direction code DCON word Design PPoint connection type DCORRO real Derived corrosion DCRFA element(10) Array of Design datasets for Design Code/Criteria DCSTYF element Design change style reference DCTILT real Default Ceiling Tile Thickness DDDF string(1000) Default Design data value DDEF real(3) Port distance flexibility defaults DDEG real Dimension line angle DDEP integer Database depth within hierarchy (World is 0) DDESP real(100) Design parameters as distance DDIR dir Design PPoint spherical direction DDNM element Design element reference DDNMX real DDNM X position DDNMXY real(2) DDNM XY position DDNMY real DDNM Y position DDNX string(120) Design element as text DDOORS real Default Door Sill DDPR string(1000) Design data property value DDRFA element(10) Array of default design datasets (for template) DEALAL logical True if location locked due to deallocation of dbs DEALDB element(1000) Reference array for locations where DB id being deallocated DECGAP real Decoration Gap DECMOD integer Decoration Mode DECOFF real(2) Decoration offset DECP integer Decimal places DECREP real Decoration Repeat DECSIZ real Decoration Size DEFA real Default DEFATT word(2000) Default List of all attributes for element DEFERD element(10000) Deferred DBs in MDB DEFHOM element Default allocation home DEFSLO real Default pipe slope DEFSPK element Default Reference of SPEC for branch members DELANG real Angle applied to repeat elements DELDSG word Delivery Designation flag DELP pos D-position in structure DELPE real Easting of D-Position in STRUC DELPN real Northing of D-position in STRUC DELPU real Upping of D-position in STRUC DELTAE real Easterly Offset applied to repeat elements DELTAN real Northerly Offset applied to repeat elements DELTAU real Vertical Offset applied to repeat elements DEMIX integer Index of Demote Status Value DENS real Spot value of density DEPATT word(2000) Attributes that a rule or catalogue parameterised expression is dependent upon DEPD string(250) word Default value of local design property DEPL word(100) List of local design properties DEPR string(250) word Local design property value DEPREF element(500) List of elements connected to branch tail DESC string(120) Description of the element DESGEO element(5000) Design geometrical dependencies DESLNK element(20) Connectivity Design Model Link DESMOD integer Design Mode DESP real(100) Design parameters DESREF element(10) Design reference DEST string(26) Destination DESXCL logical Design Outfitting excluded Geometry DETA logical Detail flag DETR element Detailing text reference DFBRADIUS real element Default bend radius DFFL real(6) Displacement force flexibility DFHOME element element, Get default home elemtype element DFLA string Radial dimension type flag DFLF real(3) Translational spring values DFLRCO string(120) Default Floor Code DFLRHE real Default Floor Height DFLRTY string(120) Default Floor Type DFLT string(120) Default value for the attribute DFLTA string(1000) Defaults for Type 1 annotation - special attribute for use by ADP DFLTB string(1000) Defaults for Type 2 annotation - special attribute for use by ADP DFLTC string(1000) Defaults for Type 3 annotation - special attribute for use by ADP DFNM string(1024) Document filename DFON integer Dimension text font DFONTN string(80) Dimension text font name DFUN element Default unit DHTEST integer(500) Test locator expression DHTEXT integer(500) Default home identifier expression DIAM real Diameter DIAREF element(500) Diagram reference array for schematic elements DIME logical DRAFT user defined symbol dimension flag DIMPOS pos Derived 3D dimension position DIMTXT string(40) Dimensions text DINTER string(257) Default Interference class DINTHK real Default insulation thickness DIR dir Direction DIREV dir Direction evaluation DIRXP integer(500) Direction expression DISP real(3) Translation displacements DIST real(2) Distances DISTAG string(120) Display tag DISTFH real Distance from head DISTFN real Distance from next point DISTFP real Distance from previous point DISTM real(2) Distances to M1 and M2 curves DKEY word Data Key DLCOLO integer Dimension line colour DLCONU integer Dimension line colour number DLEV integer Drawing level DLFG string Linear/Angular dimension line flag DLIM real(6) Displacement limit DLIST word(2000) List of all possible dist att types DLPN integer Dimension line pen DLSTREF element Dimension linestyle Reference DLSTYL integer Dimension linestyle DMFA element(2) ISODRAFT Reference Dimension attribute DMFL real(9) Displacement moment flexibility DMSP real Lower limit to spacing between parallel dimensions DMTX string(1000) Dimension text DMTY word(2) ISODRAFT Reference Dimension attribute DNST real Density DOCREF element Document reference DOCXRF element(500) Return reference from Design element to DOCITM element DOFF real Dimension line offset DOFIL string(73) Drawing Object filename DPBO real integer Design point bore DPCO word integer Design point connection type DPCOU integer Number of valid design points DPDI dir integer Design point direction DPFN string(1024) ISODRAFT dynamic detail plotfile name DPGR real integer Design Point Gradient DPGRID integer ISODRAFT dynamic detail grid reference attribute DPLS integer(200) List of valid design points DPOS pos Dimension line/arc position DPPS pos integer Design point position DPREMA real Design pres. max DPREMI real Design pres. min DPRO string(1000) Parameterised Property Expression (Default) DPSF element Design PPointset reference DPVI integer(200) List of visible design points DRAD string(1000) Radial offset DRAWNO string(26) Drawing number DREVAY element(50) DRWG revisions array DRFILE string(73) Drawing File name DRFNUM integer(11) Drawing file numbers DRFTYP integer(11) Drawing File Types DRGP integer Drawing priority (used to determine how to draw SCTN) DRMXTL integer Draft general max text length DRNE dir Plane normal at end of SCTN/GENSEC DRNS dir Plane normal at start of SCTN/GENSEC DRPS pos Derived position for steelwork DRRF element Old spooler drawing reference DRSSRE element Draft Symbol set reference DRTITL string(120) Drawing title DRTMPR element Draft template reference DRWGN string(1000) Drawing number DSCO string(120) Design code DSESS string(120) integer Date of specified session DSET logical(3) Displacement limits set flag - ignore values if FALSE DSGNTN string Designation DSTNCE real Distance DSTY string Radial dimension style flag DTAN string Dimension text angle flag DTCH real Dimension text character height DTCOLO integer Dimension text colour DTCONU integer Dimension text colour number DTER string Dimension terminator code DTFL string Dimension text radius flag DTIT string(32) Data Title DTLELE element(5000) Datal Elements list DTLH real Dimension text letter height DTLLIST word(2000) Datal Attributes List DTLTST integer(8192) Datal Test attribute DTMPMA real Design temp. max DTMPMI real Design temp. min DTOF real(2) Dimension text offset DTOP real Top diameter DTPN integer Dimension text pen DTRA real Dimension text radius DTRE element Data set reference DTUL string Dimension text underlining flag DTWTCL string Date of weight/cog calculation DTXR string(2000) RTEXT of detailing text DTXS string(2000) STEXT of detailing text DTXT string(2000) TTEXT of detailing text DUCTHE real Default duct height DUCTSH word Default duct shape DUCTWI real Default duct width DUNI word Distance units DUNION integer DRAFT element union detail flag DUPLIC element(10000) integer Duplicates of the current element with the same attribute values DUTY string(120) Duty DVFL logical ADP detail views flag DVSCL real(500) ADP detail view allowable scale list DVTH real ADP detail views threshold DWALLT real Derive wall thickness DWID string(1000) Width offset DWINSI real Default Window Sill DX string(1000) Cartesian X offset DXL string(1000) Incremental X length DY string(1000) Cartesian Y offset DYL string(1000) Incremental Y length E real Position easting EASTING pos Easting part expressed as a position ECCE pos Eccentricity (steelwork) ECCJ pos Eccentricity of joint (steelwork) ECLASS word(100) Access Control Element class ECRFA element(500) Equipment connection reference array EDGELE real Edge Length EDISTA real Vertical Distance of End EDPUV pos End point EFAC string(1000) E-factor EFOR real(3) End force vector components ELCXRF element(500) Return reference from CABLE element to ELCONN element ELDATA integer(8192) data ELDSZ integer DataSize ELECRE logical integer True if created since given session ELECREC logical True if created since comparison date ELEDEL logical integer True if deleted since given session ELEDELC logical True if deleted since comparison date ELEL word(200) Types of elements (including UDETs) to which this attribute applies ELEMOD logical integer True if modified since given session ELEMODC logical True if modified since comparison date ELEPTR integer Elemp ELESZ integer Size ELEVAT real Elevation ELEVV logical Is Elevation View ELRATI real Electrical Rating ELTYPC word Element type ELVRSN integer Element version EMOM real(3) End moment components ENCODB string DB Encoding ENDA real End angle ENDELE real End Elevation ENDOFF real Offset of the end of section ENDPOINT integer Cable End connection point ENDPOS pos End Position ENDREF element Cable End reference EPARAM real(6) Evaluated parameters EPKDI real Proportional distance of end point along Pline EPOSTO real End post tangent offset EREC integer Erection class EREL integer End releases (packed) ETEX string(1000) Example text EVOL real(6) Enclosing box volume in given coordinates EXBTEX string(1500) Expanded annotation text EXCESS real Excess EXCLEN real(3) Length of excess intervals (type 1-3) EXCLFR logical True if element claimed from this extract. Only True for Primary elements EXCLFT real Excess on left side of seam EXCLHI element(5000) Primary elements in descendant hierarchy claimed to this extract (includes this element) EXCLPA logical True if element claimed to Parent extract. Only True for Primary elements EXCLTO logical True if element claimed to this extract. Only True for Primary elements EXCNUM int(3) Number of excess intervals (type 1-3) EXCRGT real Excess on right side of seam EXCTLF integer Excess type on left side of seam EXCTRG integer Excess type on right side of seam EXDMTX string(1500) Expanded dimension text EXECAFTER string(512) Exec file after DB propagation EXECBEFORE string(512) Exec file before DB propagation EXFI integer Extract file number EXHCNC element(5000) As EXTCNC, but repeat test for all descendants EXHCNN element(5000) As EXTCNN, but repeat test for all descendants EXHCON element(5000) As EXTCON, but repeat test for all descendants EXHRCN element(5000) As EXRCN, but repeat test for all descendants EXHRCO element(5000) As EXTRCO, but repeat test for all descendants EXMOC logical As EXMOD but ignoring changes to "noclaim" attributes and member lists EXMOD logical True if element modified in this extract EXNCLH element(5000) Primary elements in descendant hierarchy not claimed to this extract EXPA real Spot value of expansion coefficient EXPIRY string(50) Protected DB Expiry date EXPLTX string(1500) Expanded projection line text EXPMOC logical As EXPMOD but ignoring changes to "noclaim" attributes and member lists EXPMOD logical True if primary and element or non-primary descendants have been modified in this extract EXPRESSION string(4000) Expression EXPTYPE string(60) Expression type EXTALS element(8191) Extract ancestors EXTBOX real(6) Defined box EXTCLS element(8191) Extract children EXTCNC element(5000) As EXTCON but excluding non modified elements EXTCNN element(5000) As EXTCON but excluding modified elements EXTCON element(5000) Primary elements connected/disconnected from element or non primary descendants in extract EXTDES element(8191) Extract descendants EXTDIR string(10) Direction of ladder exit EXTFAM element(8191) Extract family EXTHI integer Location extract number range, high limit EXTLO integer Location extract number range, low limit EXTMAS element Extract master EXTNO integer Extract number EXTNSN real Extension EXTOWN element Extract owner EXTRC string(120) Name of extract claiming element EXTRCN element(5000) As EXTCNN, but applied recursively to each connection EXTRCO element(5000) As EXTCON, but applied recursively to each connection EXTREF element References to exit level EZDI real End load point in section FAAN integer Skew angle for font file FACODE string(100) Facode FAILCO integer FailCond FAREA string(5) Construction area FCDATE integer(2) File creation date FCENTRE pos Centre of fillet arc FCLXSP real(100) Spacing between stair flights in the X direction of the tower FCLYSP real(100) Spacing between stair flights in the Y direction of the tower FCMEAS real Flange correction measure FCODE string Face code FCOE real(3) Friction coefficient FCOLOUR integer Fill colour FCONUM integer Fill colour number FCPY element Forward copy reference FDEPD string(250) word Formatted Local Design Property Default Value FDEPR string(250) word Formatted Local Design Property Value FDRA string(32) Isometric drawing number FEDEXS real(500) Feed excess values FEMCOL integer FEM image object colour FEND pos Fillet arc position FEQDES string(120) From Equipment Description FFCOLO integer Front-face colour FFCONU integer Front-face colour number FFLEXT real Edge Extension Around Floor layer FFPN integer Front-face pen FFSTREF element Front-face linestyle Reference FFSTYL integer Front-face linestyle FGAP real First offset distance FGRF element(500) Reference to boundary faces FILCHK logical FILCHK (true if fill level check is enabled ) FILEEX logical True if DB file exists and is valid FILENAME string DB filename FILL logical DRAFT user defined symbol fill flag Fill level check logical Fill level check FILLDI word Fill direction FILREF element(500) Sorted references to attachment points with ascending order of fill level greater then 0 FILTOPERATOR string(20) Filter operator FILTVALUE string(1000) Filter value FINO integer File number FINPUT string(120) Input by FIRE real Fire resistance FIRERATING string(120) Fire rating FISSUE string(12) Current pipe spec issue FITLEN real Length of branch fitting FIXT string(12) Structural fixity FLALLO real Flange allowance FLATYP integer Flange type FLCARE real Floor cover area FLCSTHICKNESS real Floor cover thickness FLCVOL real Floor cover volume FLEN string(1024) External file name FLEVEL real Fill level at route node FLIM real(3) Force limit FLLARE real Floor layer area FLLTHK real Floor layer thickness FLLVOL real Floor layer volume FLNM string(700) Full name of the element FLNN string(700) Full name of the element (without leading slash) FLOFFS real Flange offset FLOW word Flow direction FLRCOD string(120) Floor Code FLRELE real Floor Elevation FLRELV real Floor elevation FLRHEI real Floor Height FLRTYP string(120) Floor Type FLTDIR dir Stairflight Direction FLUR element Fluid reference FLWA logical DRAFT user defined symbol flow arrow FMID pos Middle point of fillet arc FNAM string(1024) Filename FNCCD integer Functional description code FNCTXT string(80) Functional description FNMA string(32) Standard font file name FNMB string(32) Bold font file name FNTD string(32) Font directory FOLDED logical True if folded FONT integer Text font FONTN string(80) Font name FOOTRO real Clear space behind each rung FORC real(3) Force vector FOREIGN string DB foreign/local FPATH string(256) File path FPEN integer Fill pen FPLINE string(32) Process line number FPON integer FROM port number FPRDE string(250) word Formatted property default FPROP string(250) word Formatted property value from dataset FRAD real Fillet radius FRDR string(32) Reference drawings FREF element Fitting reference FREV string(4) Isometric drawing revision FRMSCL real Form scale FRPO pos Eye point FRSTW element word Reference of first world of given DB type in current MDB FSPOST real Distance to the first post FSTART pos Fillet start position FSTAT string(15) Fstatus FSTNUM integer Fill style number FSTREF element Fill style Reference FSTYLE integer Fill style FSTYNO integer Fill Style Number FTCDD string(250) word Formatted Current Design Property Default Value FTCDP string(250) word Formatted Current Design Property Value FTER string First dimension terminator code FTHICKNESS real Stair Flight Thickness FULLT string type of the element FULSYS string Type of the element, ignoring UDET, not truncated FUNC string(120) Function FUNI integer FUNIT FURNRF element Furniture Reference GANGLE real General Angle GAPALL string(1000) Gap Allowance GAPF real First offset distance GAPI real Intermediate offset distance GAPS real(30) Projection line gap array GAREA real Ceiling Grid Area GASTIG logical Gas Tight GATECO string(120) Gate Configuration GATESI real(2) Gate Size GBOX real Box gap GCOF pos Gross centre of gravity GDEFIN integer(100) Glyph Outline Definition GDIAM integer Glyph Circle Diameter GENGT word Geometry type GENSTR string General strings GENTYP word Type of geometry GEODEP element(5000) Direct geometrical dependencies GEOM integer Geometry Modified- Not directly queryable GFILLD logical Glyph Primitive Filled Flag GHEIGH real Gate Height GLBSTR logical True if Project has Global structure GLBVER string(120) Global version string GLYNO integer Glyph Number GLYNUM integer Glyph Number GLYREF element Glyph Reference GMOF real(9) Gross moments of inertia GMRE element Geometry set reference GOBREF element Generating reference GOFFS integer(2) Glyph Primitive offset GOING real(10) Tread Going GPPRXS element(500) Group proxy items referring to element GPSTR string General purpose strings GRADE real Steel grade GRAXE integer Grid axes (internal) GRDAXE string Grid axes GRDDIR dir Grid direction GRDE real Gradient of implied tube. Gradient is the vertical rise(fall) divided by the horizontal distance. GRDID string(20) Grid Identifier GRDLBL string(20) Grid Label GRDLID integer(2) Gridline Identifier GRDLXP real Proportion along X gridline from Gridline ID GRDLYP real Proportion along Y gridline from Gridline ID GRDOFF real Grid offset GRDPOS pos Grid Position GRDXSP real(10000) Grid X Spacing GRDYSP real(10000) Grid Y Spacing GRIDNM element Design grid reference GRIDNX string(120) Design element as text GRIND real Grinding info GRILEN real Length of grinding intervals GRINUM integer Number of grinding intervals GRIP real Minimum distance between bends GROUPS element(500) GPSETs in which element occurs GRPRF element Reference to group (owner of location) GRSYS element Grid system reference GSRF real Gross surface area GSTR element Structural geometry set reference GTAREAS element(5000) All areas that fully or partially enclose element GTEXAREAS element(5000) All areas that fully enclose element GTXT string(120) Text storing rule to generate Inventory List GTYP word Generic type GVOL real Gross volume GWEI real Gross weight GWIDTH real Gate Width GXLEN integer Glyph Rectangle XLength GXYOFF real(2) Grid XY Offset GYLEN integer Glyph Rectangle YLength HANGLE real Hatching Angle HAZARD string(120) Hazard HAZTYP string(120) Hazard Description HBLBOX real(6) Block box HBOR real Head bore HCCNT integer Header/Extract list changes count HCOFG pos computed hull item centre of gravity HCON word Head connection type HCORRO real Head Corrosion HCREF element(10) Head connections HDBREF element Generic Hull DB Ref HDCONN element(500) List of elements connected to branch head HDIR dir Head direction HDMF element(2) ISODRAFT Reference Dimension attribute HDMT word(2) ISODRAFT Reference Dimension attribute HDREF element(500) List of attachment connected to attachment HDUPLI element(10000) integer Duplicates of the current element (checking members) HEADCL real Head Clearance HEADRO real Headroom HEATT integer Heat Treatment HEIARR real(10) Height array HEID real Default Height value HEIF real Height attractor factor HEIG real Height HEIL real(2) Height limits (Min/Max) HEIS logical Height set flag - ignore Height values if FALSE HEND string Connection at other end of HREF (HEAD or TAIL) HGHT real Height HGSIDE word Hinge side HHBO real Hanger head bore HHBP pos Bottom of hanger head HHCO word Hanger head connection type HHDR dir Hanger head direction HHGR real Hanger head gradient HHOD real Hanger head outside diameter HHPO pos Hanger head position HHTP pos Top of hanger head HIERARCHY element(5000) Structural connections HIST integer(120) attr History of sessions in which element or specified attribute were made HLCOLO string Hull Colour HLIS word(2000) List of all possible types in owning hierarchy HLSTREF element Hatching linestyle Reference HLSTYLE integer Hatching linestyle HMAV real Average humidity HMMA real Maximum humidity HMMI real Minimum humidity HNCKEY integer Hole Notch Cutout Key HOFFSE real Hatching Line Offset HOFFT real Head offset HOLGRD logical True if any hole in the plate should be ground HPATNO integer Hatch Pattern Number HPOS pos Head position HPOSE real Easting of head position HPOSN real Northing of head position HPOSU real Upping of head position HPREF element Head point reference HREF element Head reference HREL logical Branch Member Head relative flag (Router) HRJUSL word Handrail Justification Line HRSF element Hatch ruleset reference HSARFA element(500) HVACSpool arrive references HSEPAR real Hatching Line Separation HSLRFA element(500) HVACSpool leave references HSPE element Hanger specification HSRFA real Computed Hull item surface area HSRO element Headrod specification HSTU element Head tube specification HSTYF element Hatch style reference HTBO real Hanger tail bore HTBP pos Bottom of hanger tail HTCO word Hanger tail connection type HTDR dir Hanger tail direction HTGR real Hanger tail gradient HTOD real Hanger tail outside diameter HTPO pos Hanger tail position HTPREF element Topology reference HTTP pos Top of hanger tail HTYP word Hanger type HUBRF element Reference to the hub location HULAPP logical Hull applicable Geometry HULCNT integer Size of hull array/collection HULLDE logical True if element is a hull design item HULLOB element Hull object reference HULLPR logical True if element is a hull production item HULOC string Location HUMIDI real Design Humidity HUMIRR logical True if mirrored in local v-axis HUMVW string Model View HUREFL logical Reflected HUREPL element Replica HUSYMM logical Symmetrical HVOLU real Computed Hull Item volume HWALLT real Head wall thickness HWEIG real computed analytic hull item weight HWRF element Head Working Point (Router) IBLNAM string Name of idealised block ICAT element Insulation catalogue reference ICLASS string(120) Interference class ICON string(120) ICON ICONL string(120) ICONL ICONN integer COMMS connection type (0/1 = on/off-line) ICONS string(120) ICONS ICOTYP string(300) Icon used for element IDENT string Panel identification string IDET element Insulation detail text reference IDLABL real Length of label idle movement IDLFAC real Idle movement factor IDLL real(3) Burning idle length IDLLEN real(2) Non-burning idle length IDLN element Drawlist name reference IDLX string(120) Drawlist name (as text) IDNM element Design data or catalogue component IDNX string(120) Design data or catalogue component (as text) IDRT string(2000) Insulation detail RTEXT IDSPU integer Specified unique identifier IDST string(2000) Insulation detail STEXT IDTT string(2000) Insulation detail TTEXT IGAP real Intermediate offset distance IGNDUN logical Ignore DUnion flag IMAT element Insulation material text reference IMGDAT integer(8192) Image data IMPED string(1000) Impedance IMXT string(2000) Insulation material XTEXT IMYT string(2000) Insulation material YTEXT IMZT string(2000) Insulation material ZTEXT INCBOR real Inch Nominal Bore INCL real Inclination angle INFA string(119) Client info - Project Name INFB string(119) Comment - Project Message INFG logical Insulation flag INFOTE string(120) Infotext INIVAL element Initial Value INMTRF element INSMAT Reference INPINDEN real Insulation pin density (Area) INPINLEN real Pin length INPINT string(120) Insulation pin type INPRTR element Inside paint reference INRE element Insulation reference INRF element Array of Inventory Items INSARE real Insulation requirement area INSC string(120) Inspection schedule INSL logical DRAFT user defined symbol insulation flag INSTNC string Bracket instance name INSTOPTIONS string(120) Installation Options INSURE element Reference to a INSCMP element INSUTY string(120) Insulation type INSYST element(500) Reference Array of all SYSGRPs Elements INTHK real Insulation thickness INTSEN logical Installation Sense - true if clockwise INTY word Inventory item type INVF element(500) Array of Inventory Items INVI logical(500) Visibility state IPAR real(30) Parameters of the insulation catalogue component IPRE real Internal pressure IRNO string ISO-IR number ISCOPY logical True if a copy DB ISDBFR logical True if database is foreign ISDBPR logical True if database is primary for global working ISDRDB logical True if database has drawings ISECPT pos Intersection point ISEXAP logical True if extract ancestry is primary here ISEXCP logical True if all extract children are primary here ISEXMP logical True if extract master is primary here ISEXOP logical True if extract owner is primary here ISEXTR logical True if an extract ISFOR logical True if database is foreign ISKEYDB logical Does ukey incorporate DB number ISLOADED logical True if Sheet is loaded ISMAST logical True if a Master DB, that is top level extract ISNAMED logical True if element is named ISOHIDDEN logical Isohidden flag ISPE element Insulation spec reference ISPICF logical Picture has File ISPR element Insulation specification component reference ISPRIM logical True if database is primary at this location ISSUE logical True if drawing has been issued ISWORK logical True if a working extract ITLE real Length of implied tube ITMTBL integer(2000) Table linking AITEMS elements to piping components ITPS pos Position of implied tube IWDORF element(1500) Weld owners attribute on IWELD elements IWDOWN integer(8) Table linking IWELD elements to piping components JFRE logical True if Section position dominates a connection JLIN word Joining line JLNE word Joining line end JLNS word Joining line start JMAX integer Maximum joint number in current spool drawing JNTBEV real(2) Joint part bevel code JNTC integer Joint Code JNTCOM string(300) Welded joint comment JNTNAM string(26) Welded joint name JNTNUMBER integer Joint number JNTORF element(1500) Joint owners attribute on IJOINT elements JNTOWN integer(8) Table linking IJOINT elements to piping components JNTREF element integer Return reference from Ppoint to ijoint element JNTTHK real(2) Joint part thickness JNTTSL real Total welded joint suspension length JNTTWL real Total welded joint length JNTTYP string(26) Welded joint type JNUM integer(2) Old spooler joint number JOIE element End joint JOIP word(2) Old spooler joint number prefix JOIS element Start joint JUSL word Justification Pline JUST string Justification KNUANG real Knuckle angle KNUCKL logical True if knuckled LABOFFS real(3) Label offset LABPOS pos Label position LABST integer Number of starts for label signing LACR logical Access Control on/off switch LACTIV logical True if selectable : false = limbospec LALCAB element(500) List arriving leaving cables on attached point LALLAN real Leave Ppoint allowed angle LASTM string(120) attr Date of last modification LAUTHU logical Login Authentication on/off switch LAXE ori Local axes LAYARF element Annotation Layer ruleset reference LAYDRF element Design Layer ruleset reference LAYTBF element Layer Table reference LBBORE logical TRUE if Minor/Branch bore is in nominal bore table LBOP pos Bottom of leave pipe LBOR real Leave bore LCAS integer Load case number LCHA logical Chain flag LCIRCR real(8) Least circumscribed rectangle LCKPSW logical Lock passwords for general users LCLAIM logical Access Control Claim flag LCLM logical True if element is claimed LCLMH logical True if element and hierarchy claimed LCNFA element(500) Array of elements with local names LCON word Leave connection type LCORRO real Leave corrosion allowance LCPOVWRITE logical Location Overwrite DB Users policy flag LCTROL logical Controlled DB Flag LCUTDI dir Lower Extension Cutting Direction LDFLT logical logical default value for a UDA LDI dir Leave direction LDISP logical Display property flag for design datasets: True if property is shown on form LDPR real word Local design dataset property LDRDIR dir Ladder Direction LEAFS real Number of door leafs LEAHEI real Leave height LEAV integer Leave Ppoint LEAWID real Leave width LEND logical Line end LENDTI integer Time out period for commands LENG real Length LENSEG real Length of segment LETTER string(120) Letter LEVE integer(2) Drawing level LEVENL integer Time interval for Event Loop LEVRFA element(500) References to levels serviced by stairwell LEXTNS real Lower Extension Length LFADIR dir Flight A Direction LFAOFFSET real Landing Flight A Offset LFBDIR dir Landing Flight B Direction LFBOFFSET real Landing Flight B Offset LFCOLO integer Label frame colour LFCONU integer Label frame colour number LFDP element word Local design dataset property LFPN integer Label frame pen LFRA logical Frame flag LFSTREF element Label frame linestyle Reference LFSTYL integer Label frame linestyle LGAP real Last offset distance LGOING real(10) Lower Tread Going LGRD real Leave Ppoint gradient LHBORE logical TRUE if Major/Header bore is in nominal bore table LHEA logical Logical head flag LHEI real Letter height LHIDE logical Hide flag for catalogue datasets: True if property is not shown on form LIGHTI real Lighting requirements LIMI real(6) Volume of interest LIMNUM integer Order number of limit LINIT logical Location initialisation flag LINKRE element Link reference LINKS element(5000) Linked elements LINKSN integer Linked session on parent extract LINKXR element(1000) Referencing elements LISS logical True if drawing has been issued LIST word(2000) List of all possible member types LLCL real Leader line clearance LLCOLO integer Label leader colour LLCONU integer Label leader colour number LLDIAGRAMS string(2000) Line list diagrams LLEA logical Leader line flag LLENG real Leave length LLENTRY logical Is a line list entry - true or false LLFROM string(2000) From column text for a line list LLIS word(2000) List of all possible types in member hierarchy LLPN integer Label leader pen LLSTREF element Label leader linestyle Reference LLSTYL integer Label leader linestyle LLTBRANCH element Line list tail branch LLTO string(2000) To column text for a line list LMAXTR integer Maximum number of retries for command LMERDL logical PDMS GLOBAL Enable automatic merge of transaction db LMERFAILURE integer Number of days Failed commands persist in Trans dB LMERSUCCESS integer Number of days Successful commands persist in Trans dB LMERTI string(120) Frequency of Auto Merge of Transaction DB LMIRR logical True if Mirroring required LNAME string(20) Local name as stored on template LNDLEV real(100) Landing levels from owning element LNFA element(480) Hidden Reference Array for linked Vertices LNKCLS element(500) Classes referencing a DocLink LNKDOC element(500) DocLinks referring to element LNKELE element(500) Elements referencing a DocLink LNKPRP word TRUE if item pointed to by descriptor should be propagated by Global LNKREF element Reference internal document (drawing/sheet) LNKRX element Reference to first location of a link LNKRY element Reference to second location of a link LNKUSE word Link Descriptor Usage LNKWV integer Link weighting value LNLST string(2000) List of local names for current template LNOUPDATE logical DB propagation suppressed flag LNPRXS element(500) Proxy items referring to element LNTP word Line type LOCA string(120) Location LOCID string(3) Location identifier LOCK logical True if element is locked LOCPR element(1000) List of LOCs Primary at location LOCRF element Location reference LOCTYP integer Location LOD real Leave Ppoint outside diameter LOFF logical Offline flag LOGEV logical Logical value evaluation LOGFN string(1024) COMMS log file name LOGLV integer COMMS log file level of detail LOGMS logical COMMS log file active/inactive flag LOGXP integer(500) Logical expression LOHE real PLOOP height - from first PLOOP in owning panel LOOS logical Loose LOWGAP real Lower Gap LOWPOS pos Point nearest workshop floor LOWREF element References to lower exit level LPOS pos Leave position LPOSE real Easting of leave position LPOSN real Northing of leave position LPOSU real Upping of leave position LPROT logical Protected DB Flag LQAANG real Angle between alignment direction of leave Ppoint and next LQANG real Angle between leave Ppoint and next component LQBORE logical TRUE if leave Ppoint has same bore as next LQCON logical TRUE if leave Ppoint has Correct connection type LQOFF real Offset between leave Ppoint and next component LRBORE logical TRUE if bores is in reducer table LREF element Link reference LREFO logical Database holds Reference data only flag LRISE real Lower Tread Rise LSELEC logical True if can be set Directly in Design LSHA string Leader shape code LSPA real Text line spacing factor LSRO element Leave rod specification LSTR logical Stress flag LSTU element Leave tube reference LSTYNO integer Line Style Number LSWID real Line Style Width LSWKEY string(120) Line Style Width Key LTAI logical Logical tail flag LTBORE logical TRUE if bores is in branch (tee) table LTCORR real Leave tube corrosion allowance LTER string Label terminator code LTHICK real Door leaf thickness LTIMEI integer Time Interval between retries LTLE real Length of leave implied tube LTOP pos Top of leave pipe LTWALL real Leave tube wall thickness LTWREF element Leave tube wall thickness reference LVAR logical Variant Flag LVIS logical Visibility flag LVOL real(6) Enclosing box volume in local coordinates LWAITD integer Time interval between re-sending commands LWALLT real Leave wall thickness LWIDTH real Line Width LWP pos Lower Working Point LYCOL integer AutoCAD Layer Colour LYCVFR logical AutoCAD Layer Current Viewport Freeze LYDIR dir Leave Y axis direction on point LYFRZE logical AutoCAD Layer Freeze flag LYLOCK logical AutoCAD Layer Lock flag LYLTYP string(120) AutoCAD Layer LineType LYLWT real AutoCAD Layer LineWeight LYNVFR logical AutoCAD Layer New Viewport Freeze LYPFG logical AutoCAD Layer Plotting flag LYPSTY string(120) AutoCAD Layer Plotter Style LYVIS logical AutoCAD Layer Visibility Flag LZDIR dir Leave alignment direction MACRID string Clip macro ID MAINTENANCE real Maintenance level radiation MAKER string(100) Maker MANBLK string Name of owner block MANCOG pos Center of gravity MANLEN real Length of manual intervals MANNUM integer Number of manual intervals MANPAN string Name of owner panel MANTRA real(16) Transformation from local coordinate system MANTYP string(26) Manufactured type, for example. Plane, Curved,... MANU string(120) Manufacturer Name MANWGH real Weight MARKRF element(100) Cable Mark points MARPTY integer Marine picture type MATANG real Material Lay Angle MATDEN real Material density MATDIR dir Material direction MATID integer Material ID MATLEN real Material Length MATN string(1000) Material Note MATOVE real Material Overlap MATPURPOSE word Material purpose MATR element Material reference MATWID real Material Width MATX element Material text MAXA real Maximum answer MAXARE real Maximum area MAXB real Maximum bore MAXD integer DB hierarchy depth of lowest level item beneath element MAXFIL real Maximum percentage fill level MAXHUM real Maximum Humidity MAXLP real Maximum length of pipe MAXMIN real(2) Maximum and minimum values of design property MAXOD real Maximum Outer Diameter MAXPLN pos Maximum Plane Position MAXPRE real Maximum Pressure MAXREP integer Maximum number of Repeat items created MAXSLO real Maximum pipe slope MAXTEM real Maximum Temperature MAXU integer Maximum number of user MAXVOL real Maximum Volume MAXWAT real Maximum Water Level MBACK element(10000) elemtype Members in reverse order MBUFS integer Preferred buffer size in MBytes MCBENT logical Machine bent MCOLOUR integer Marker colour MCONUM integer Marker colour number MCOU integer elemtype Number of Element Members of Given type MDBCLS element(1000) List of MDBs in which DB is current MDBLS element(1000) List of MDBs to which DB belongs MDSYSF element(10) Reference Array of Model and Design Elements MELRFA element(500) All components (non- tube) in the PipePiece MEMB element(10000) elemtype All members, or members of specific type MEMDAB element(10000) Dabacon members MEML word Member line for SCTNs MEMNAM string(120) Member name MEMTYP string(256) Member type array MFAR word(50) Model Function Word array MFFIND element Find Manufacturingpackage folder MFLG logical Master link flag - SLAVE if FALSE MIDP pos Section midpoint (steelwork) MINARE real Minimum area MINBEN string(1000) Minimum Bend Radius MINFED real(500) Minimum feed values MINFIL real Min Fill level on Cableway and Cabletray components MINHUM real Minimum Humidity MINLP real Minimum length of pipe MINOD real Minimum Outer Diameter MINPLN pos Minimum Plane Position MINPOS integer Smallest position number of nested plate parts MINPRE real Minimum Pressure MINSLO real Minimum pipe slope MINTEM real Minimum Temperature MINVER real Minimum vertical pipe slope MINVOL real Minimum Volume MIRROR logical True if mirrored in local v-axis MLEF real Minimum length excluding flange MLIF real Minimum length including flange MLIM real(3) Moment limits MLNCOL integer Member-line colour MLNCON integer Member-line colour number MLNP integer Member line pen MLNSTREF element Member-line linestyle Reference MLNSTY integer Member-line linestyle MMBOR real MM Nominal Bore MODATT logical attr True if attribute of element can be modified MODDEL logical attr True if element can be deleted MODERR string(120) attr Returns the error text that would occur if attribute was modified MODID string(2000) LMI Model ID MODREF element Model reference MODU string(120) Module MOFI pos Moment of Inertia MOME real(3) Moment MOULEN real Mould length MPEN integer Marker pen MPFIND element Find Manufacturingpackage MPKGFD element Find Manufacturingpackage MPKGFI integer(500) Manufacturing Package Filter Expression MPKGRF element Manufacturing Package Reference MRGF logical ADP merge flag MRGL word ADP merge level MRKLEN real Total marking length MRKR word 3 way component marker MRKST integer Number of starts for marking MSESS integer attr Last session number MSTREF element Marker style Reference MSTYLE integer Marker style MTBE element Material tube start. The first component, excluding ATTSs, for whom the LOFF is invalid or false MTCL real Material tube centreline length. MTEN element Material tube end. The first component, excluding ATTSs, for whom the LOFF is invalid or false MTLE real Material tube length for TUBI. Includes preceding bend length if bend is offline. MTOC word Material list control for components MTOH word Material list control for head tube MTOL string(1000) Material List Length MTOPARTNUMBERS integer(20) Additional spooling item part numbers MTOQ string(1000) Material take off quantity MTOR element(20) Extra material list spec references MTOT word Material list control for components leave tube MTOX integer(20) Old spooler addition items MTXR element Material text reference MTXX string(2000) XTEXT of material text MTXY string(2000) YTEXT of material text MTXZ string(2000) ZTEXT of material text MULT real Multiplier factor (unit definition) MVER element Reference to Master Vertex MYINSF element Surface Treatment Reference MYOUSF element Surface Treatment Reference MYSRFT element word Surface Treatment Reference N real Position northing NACCNT integer Non-additive changes count NAME string(500) Name of the element NAMEDB string DB name NAMESQ string(700) Type. sequence number and name of element NAMETY string(700) Type and name of the element NAMN string(500) Name of the element (without leading slash) NAMTYP string(700) Type and full name of element NANGLE real North angle NARE element Reference to neutral axis NBEVIT real(2) Pathtime except starts, I- bevel NBEVXT real(2) Pathtime except starts, X-bevel NBEVYT real(2) Pathtime except starts, Y-bevel NBORE real Allowable Nominal Bore NCHAR integer Number of label characters NCOF pos Nett centre of gravity NCOL integer Number of columns NCONNE integer Mismatched connections. that is no valid backpointer NCUTNT integer Number of cutouts and notches NCUTS integer Number of cuts in a mitred bend NDFLT real Numeric default value for a UDA NDTINT integer(2) NC tape date NDTTXT string(22) NC tape date text NGMR element Negative geometry set reference NGSD integer Number of GSDs NHOLE integer Number of holes NIDLAB real Pathtime except idle time for label NIDLT real(2) Pathtime except idle time NLCOLO integer Note colour NLCONU integer Note colour number NLOA real Nominal load NLPN integer Note/framing pen NLSTREF element Note linestyle Reference NLSTRT integer Number of label starts NLSTYL integer Note linestyle NMOF real(9) Nett moments of inertia NOCLIP logical View no clipping flag NOCOL integer Number of pin jig columns NODIMS logical No Dims Flag NOEXTCREATION logical Location extract create suppression flag NOFF integer Number off NOFG logical Link constraint inversion flag NOHLRF logical NoHLRFlag NOISEC string(104) Noise category NOMARK logical True if unmarked NOMBIN real(200) word List of valid Nominal bores in Inches NOMBMM real(200) word List of valid Nominal bores in MM NOMREF element Nominal bore table reference NOMXRF element(500) Return reference from NOMTAB element to SPECs NOPGS integer Number of openings NORM dir Plane normal NOROW integer Number of pin jig rows NORTHING pos Northing part expressed as a position NOSOFF real Nosing Offset NOTF element Cross-reference to NOTE/VNOT/SYTM NOTREAD integer(10) Number of treads NPDESC element(5000) List of non primary offspring NPILL integer Number of jig pillars NPLDFA string(80) Nesting default file 1 NPLDFB string(80) Nesting default file 2 NPLIST element(500) All NATPs attached to route node NPLMIR integer Quantity mirrored nested plates NPLNOR integer Quantity normal nested plates NPLTOT integer Total quantity nested plates NPOS pos Position in owner NPOSE real Easting of position wrt owner NPOSN real Northing of position wrt owner NPOSU real Upping of position wrt owner NPPT integer Ppoint number NPRSID string(26) Side of nested profile NPRVEC real(2) Local rotation vector of part NPSIDE string(80) Side of nested part NPXYP real(2) Local position of part NREL integer Nodal releases NROW integer Number of rows NRPARM integer Number of rest plate parameters NRULEE integer Number of rule inconsistencies on element NSIZ real Nominal size NSPE element Specification for NOZZLE NSRF real Nett surface area NSTART integer(2) Number of non-burning starts NSTD element Non-standard bolt length (reference to DTAB) NSTFAC real Number of starts - factor NSTRT integer(3) Number of burning starts NSTRTI integer(2) Number of burning starts I-bevel NSTRTX integer(2) Number of burning starts X-bevel NSTRTY integer(2) Number of burning starts Y-bevel NTEXT string(12) Null text NTRLEN real Neutral length NUCDNA real Distance to nearest anchor NUCDNE real Distance to the Nearest Edge NUCDNR element(2) Nearest Adjacent Anchor NUMB integer Number NUMBDB integer DB number NUMCOR integer Number of cores in a cable NUMOFF integer Number of Sheets in Drawing NUSED integer Number of used raw plates NVIEWF string(73) integer Neutral viewer filename NVOL real Nett volume NWEI real Nett weight NWELDS integer Number of attached welds on a piping component NXTDBN integer Next DB number NXTDBU integer Next Unique DB number NXTEXN integer Next DB extract number NXTFDB integer Next DB file and DB number NXTFLN integer Next DB file number NXTHB element Reference to next (future) hub NXTKEY integer next UDA/UDET key OANG real Overlay sheet angle OBCOLO integer Obscured face colour OBCONU integer Obscured face colour number OBFG logical Obstruction flag OBJCD integer(2) Object codes OBPN integer Obscured face pen OBST integer Obstruction level OBSTREF element Obscured face linestyle Reference OBSTYL integer Obscured face linestyle OCCTYP string(50) Occupancy Type OCCUPA real Occupancy OCOD string Hashed origin code OCONE integer Objectcode 1 OCTWO integer Objectcode 2 OD real Outer Diameter ODESP real(100) Owning design parameters OFFDIR dir Offset direction applied to repeat OFFDIS real Offset distance applied to repeat elements OFFSET real Offset OFFTOL string(1000) PPoint offset tolerance OFFTYP word Offset type: DELTA, LINEAR, RADIAL OGDSTS real(25) Distances to openings OGOING real Overall Going OKCLA logical True if element may be claimed OKCLH logical True if element and hierarchy may be claimed OKDROP logical True if element may be dropped OKDRPH element(5000) Primary elements preventing hierarchy drop OKREL logical True if element may be released OKRLEH element(5000) Primary elements preventing hierarchy release OKRLEX logical True if element may be extract released OKRLH logical True if element and hierarchy may be released OLCOLO integer Outline colour OLCONU integer Outline colour number OLDKEY integer Old key OLENGTH real Overall length OLIS word(2000) List of all possible owner types OLOFF real OffsetLine offset from baseline OLPEN integer Outline pen OLSTREF element Outline linestyle Reference OLSTYL integer Outline linestyle OMITFG logical Omission flag ONPJ pos Owning neutral point of joint (steelwork) ONPO real(2) ONTO Point, position of view in the region ONPS pos Owning neutral point of section (steelwork) OPAR real(100) Owning parameters - catalogue component OPCLA word Claim Access Control Operation OPCOP word Copy-From Access Control Operation OPCRE word Create Access Control Operation OPCREF element Offpage connector reference OPDEL word Delete Access Control Operation OPDI dir Origin plane direction OPDRO word Drop Access Control Operation OPERAT string(26) Operator OPEXP word Export Access Control Operation OPHEIG real Operational Height OPISS word Issue Access Control Operation OPLENG real Operational Length OPMOD word Modify Access Control Operation OPNSIZE real(2) Opening size OPOS pos Overlay sheet position OPOUT word Output (DATAL) Access Control Operation OPREMA real Operating pres. max OPREMI real Operating pres. min OPTEMP real Operational temperature OPWIDT real Operational Width ORI ori Orientation ORIA real(3) Orientation as angles ORIF logical Orientation flag ORIN word DRAFT user defined symbol orientation ORISE real Overall Rising ORNA string(1000) Originator text ORRF element Origin reference (for templates) OSDWG string(120) AutoCAD overlay name OSET logical Offset/VIEW position flag OSFN string(1024) Overlay sheet file OSHT real Overshoot OSLV real(12) Overlay sheet view layers visible OSRF element Overlay sheet ref OSTYPE word Short cut for "Type of owner" OTHLEN real Length of other intervals OTHNUM integer Number of other intervals OTMPMA real Operating temp. max OTMPMI real Operating temp. min OUAREA real Area of outer contour OUPRTR element Outside paint reference OUTD string(1000) Outside diameter OUTFRF element Reference of matching outfit object OUTSD string(1000) Outside shield diameter OVCWIDTH real Overall cables width OVRSH real Overshoot (d-measure) for unsymmetrical flange OWNC word Owning connection type OWNER element Element owner in database hierarchy OWNEXPRESSION string(4000) Owner expression OWNEXTYPE string(60) Owner expression type OWNLST element(100) Owning hierarchy PAAX string(30) Direction of axis PAGE integer(500) Page in diagram PAINTO string(26) Painting other side PAINTT string(26) Painting this side PAIREF element Reference to a PAINT element PALIG real Panel alignment PALLAN real integer Ppoint allowed angle PANESI real(2) Panel Size PANG string(1000) Angle subtended PANREF element Panel reference PANSCD integer Panel storing code PANSID integer Side of panel PANSTC integer Panel storing code PARA real(100) Parameters PARAL logical True if tap parallel to referred seam PARCOLUMN element Parent column PARENT element elemtype Reference of ascendant element of specified type PARM real(6) Parameters PARNAM string(256) Part name PARREF element(10) Part reference PARTNUMBER integer Part number of a spooled component or leave tube PASS string(7) Password PASSQ integer Password Quality PATADV real Line Pattern Advance value PATDEF integer(20) Pattern Definition PATH element(500) Path PATHTM real Path time for selected burning machine PATNAM string Pattern Name PATOFF real Line Pattern Offset PATREP real Pattern Repeat PAXI string(30) Axial direction PBAX string(30) Direction PBBT string(1000) Bottom B length PBDI string(1000) Distance to bottom surface PBDM string(1000) Snout bottom diameter PBENDNUMBER integer Spooling pulled bend number PBOF string(1000) B offset PBOP pos integer Bottom of pipe PBOR string(1000) Bore PBTP string(1000) Top B length PCAX string(30) Direction of C offset PCBT string(1000) Bottom C length PCODA integer Precision code angles PCODE integer Precision code PCODF integer Precision code fractions PCODI integer Precision code imperial PCODM integer Precision code metric PCOF string(1000) C offset PCON string(1000) Connection type PCONDE string(120) integer Ppoint connection description PCORRO real integer P Tube corrosion PCPIDV element(10000) Enabled for project copy PCPSET element(10000) Enabled for project copy PCREF integer(4) integer Ppoint and ref of connected piping component PCRFA element(500) All spools that contain this element PCTP string(1000) Top C length PCWALL real integer Ppoint connect wall thickness PDAREF element Pipe data table reference PDEFI string Primitive Definition PDEREF element integer Pipe data element reference PDIA string(1000) Diameter parameter PDIR dir integer Ppoint direction PDIS string(1000) Distance parameter PDTINT integer(2) Production date PDTTXT string(22) Production date text PERS real Perspective angle PFLALL string(1000) Flange allowance parameter PFLOFF string(1000) Flange offset parameter PFON integer Projection line text font PFONTN string(80) Projection line text font name PFRE element Pfitting reference for Cofittings PFREQ logical Picture file required flag PGRD real integer Ppoint gradient PHBO real Pipe head bore PHBP pos Bottom of pipe head PHCO word Pipe head connection type PHDR dir Pipe head direction PHEI string(1000) Height PHGR real Pipe head gradient PHOD real Pipe head outside diameter PHPO pos Pipe head position PHTP pos Top of pipe head PICF string(73) Picture filename PICFD logical Picture file distribution flag PICHTY word Hard type of picture PICSTY word Soft type of picture PINDEN real Pin Density PIPSYM logical Pipe-end symbol flag PITCH real(10) Pitch of stair flight PITCHO real Angular offset from ladder pitch PJUS string Projection line text justification PKDI real Proportional distance along Pline PKEY word Pline identifier key PLALEN real Raw plate length PLANU string(1000) Planning Unit PLANV logical Is Plan View PLAREA real Area PLATYP string(26) Type of plate , for example. Plate, Bracket, Clip,... PLAWDT real Raw plate width PLAX string(120) 2D direction angle PLCL real Projection line clearance PLCLFL logical Proj. line clearance flag PLCN logical word Pline centreline flag PLCO word word Pline connection PLCOLO integer Projection line colour PLCONU integer Projection line colour number PLDE string(120) word Pline description PLDI real(3) Projection line direction PLED dir Plane entry direction PLEN pos word Pline end PLENCU pos word Pline end, allowing for cutback PLFG logical Plines flag PLINON logical Pline-required flag PLLE integer(2) word Pline level PLLS word(100) List of valid Plines PLNA word(100) List of available Pline names PLNCOL integer Pline colour PLNCON integer Pline colour number PLNP integer Pline pen PLNSTREF element Pline linestyle Reference PLNSTY integer Pline linestyle PLOR ori word Pline orientation PLPM word Plane pipe packing method - nearest or weighted PLPN integer Projection line pen PLPP word Plane pipe positioning code word used by Router PLPU word word Pline purpose PLRD dir Plane routine direction PLREFS element(5000) Pline references PLRF element Plane reference PLSP real Projection line text line spacing PLST pos word Pline start PLSTCU pos word Pline start, allowing for cutback PLSTREF element Projection linestyle Reference PLSTYL integer Projection linestyle PLTU logical word Pline tube flag PLTX string(1000) Projection line text PLVI word(200) List of visible Plines PLVIF integer word Pline visibility flag PLWW word Plane wall to wall positioning code used by Router PMAX integer Maximum part number in current spool drawing PMLFUN string(120) PML Function name PMLNAM string(120) Name of Pmlobject PMOD string Plane mode PNAM string(12) Property description PNTUV pos Point2D PNTXYZ pos Point3D POCK word Is a branch component in a pocket POD real integer Ppoint outside diameter POEF logical Post-evaluation flag POFF string(1000) Offset POINUM integer Point Num POIS real Spot value of Poissons ratio POITYP string(120) Point type POS pos Position POSE pos End point position POSEE real Easting of end point position POSEU real Upping of end point position POSEV pos Position evaluation POSEY real Northing (Y coordinate) of end point position POSF logical Positioning flag POSFOR string Intelligent Text positional code word expansion style POSL word Positioning line POSN real Northing of position POSNO integer Position number POSREF element Reference to point POSS pos Start point position POSSE real Easting of start point position POSSN real Northing of start point position POSSU real Upping of start point position POSTSP real Default post spacing POSU real Upping of position POSX real Easting (X coordinate) of position POSXP integer(500) Position expression POWFAC real Powder point factor PPANFL real Pipe Piece Angle between flanges PPAREF element Pipe Piece Arrive Reference PPBO real integer Ppoint bore PPBRAD real(500) Pipe piece bend radii PPBRAT real(500) Pipe piece bend ratio PPCNBD logical Pipe piece contains bends PPCO word integer Ppoint connection type PPCOU integer Number of valid Ppoints PPCUTL real Cut Length PPDE string(120) integer Ppoint description PPDI integer Ppoint number for direction PPEFR logical Leave flange required PPER element Pipe piece end reference PPEXST logical integer True if Ppoint exists PPFINL real Finished Length PPFMCV logical Pipe piece fabrication machines verified PPHEI real integer Ppoint height PPLREF element Pipe Piece Leave Reference PPLS integer(200) List of valid Ppoints PPMODI logical Pipe piece modified PPNU integer Design PPoint/Port number PPOFFT real integer Ppoint offset PPOS pos integer Ppoint position PPRFA element(500) All components in the PipePiece PPRO string(1000) Parameterised Property Expression PPSFR logical Arrive flange required PPSK word integer Ppoint pskey PPSPEC element Pipe Piece Specification PPSR element Pipe piece start reference PPUR word integer Ppoint purpose PPVBMC element Return the bending machine IF the pipe piece is verified PPVERI word Pipe piece verified PPVI integer(200) List of visible Ppoints PPVIF integer integer Ppoint visibility flag PPVWMC element Return the welding machine IF the pipe piece is verified PPWID real integer Ppoint width PQAANG real integer Angle between alignment direction of specified pp and adjacent component PQANG real integer Angle between specified Ppoint and adjacent component PQBORE logical integer TRUE if specified Ppoint has same bore as adjacent PQCON logical integer TRUE if leave Ppoint has Correct connection type PQOFF real integer Offset between specified Ppoint and adjacent component PQUA word Property qualifier PRAD string(1000) Radius PRAV real Average pressure PRDE string(250) word Property default PREF logical Pre-evaluation flag PREFIX string(120) Prefix PREPPR string(26) Preparation information PREPT real Preparation time PRES real Pressure PRFC string(1000) Pressure factor PRFELE element Cableway profile element PRFG logical Profile flag PRFL string(120) Profile PRFOBS integer Cableway profile obstructions PRICEE real Price estimate PRIMDB string Global status of DB, primary or secondary PRIMEM logical Primary member PRIMSY element Reference of the primary system elements PRIMTY logical True if element is primary PRITYP string(120) Gpart Primary type PRJD string(180) Project description PRJID string(8) Project id. Available on STAT or GSTAT element PRJL logical Project lock PRJN string(17) Project number PRJSTA word Access Control project status PRLS word(100) List of valid properties - catalogue or design PRMA real Maximum pressure PRMDIR dir Primary Direction PRMI real Minimum pressure PRMLOC element Primary location PRMMEM logical True if there are any primary elements amongst descendants PRMOWN element Primary owning element (will be itself if primary) PRMRF element Primary Location Element PRMVI logical Draughting primitive visibility PROCDE string(2400) PROCess DEscription PRODID string(104) Product id PRODRF element Reference to Production Object PRODUCTION real Production level radiation PROJID integer(3) PROJID - on the DB element PROLEN real Raw profile length PROMIX integer Index of Promote Status Value PROMPT string(160) User prompt PROP string(250) word Property value from catalogue or design dataset PROPG logical DB propagation flag PROPRE real attr Calculated Property Real Attribute PROSID integer Plate side with most profile markings PRPU word word Property purpose PRTI string(120) word Property title PRTIDL string(132) Long part id PRTIDM string(132) Module part id PRTIDS string(132) Short part id PRTLST string(26) Parts list name PRTREF element Part reference PRTRTX string(1000) word Part element R text PRTSTX string(1000) word Part element S text PRTTTX string(1000) word Part element T text PRTXRF element(500) Return reference from PART element to SPCOs PRVRF element Reference to previous owner of DB PRVSES integer integer Previous Session to that specified PSARFA element(500) Pipespool arrive references PSATTS word(500) List of pseudo attributes PSESS integer integer Previous session number PSFG logical Piping component symbol flag PSIZE real(2) Panel size PSKE word Key for ISODRAFT PSLRFA element(500) Pipespool leave references PSPE element Pipe specification PSPIN integer Ppoint number showing position of spindle PSTAT integer Plane status PSTF element Pointset reference PSTR element Structural Pline set reference PSTYP word Spool Type PSVLD logical Pipespool valid PTAN string Projection line text angle flag PTBO real Pipe tail bore PTBP pos Bottom of pipe tail PTCDI string(1000) Parameterised direction PTCH real Projection text character height PTCO word Pipe tail connection type PTCOLO integer Projection text colour PTCONU integer Projection text colour number PTCPOS string(250) Parameterised position PTDI string(1000) Distance to top surface PTDM string(1000) Snout top diameter PTDR dir Pipe tail direction PTDTRE element Part Data set reference PTEM real Pipework temperature PTEPOS string(250) Parameterised end position PTFA element(17) Point references PTGR real Pipe tail gradient PTLH real Projection text letter height PTNB integer(20) Old spooler bolt part number PTNH integer Old spooler head tube part number PTNO integer Old spooler component part number PTNT integer Old spooler tube part number PTOD real Pipe tail outside diameter PTOF real(2) Projection line text offset PTOLER real Tolerance on a design property PTOP pos integer Top of pipe PTPN integer Projection text pen PTPO pos Pipe tail position PTPTXT string(26) Profile type. for example. Stiffener, Flange,... PTRE element Point set reference PTRF element Point reference PTS integer(6) Line definition points PTSP string(120) Paint specification PTSPOS string(250) Parameterised start position PTTP pos Top of pipe tail PTYP word Property type PUCD string(100) Paint Code PUINCD string(120) Inside punch code PUNCHT real Punching time PUNI string(32) Data Property Units PUOUCD string(120) Outside punch code PURCH string(26) Purchase information PURP word Description code word PVIF integer PPoint/Pline visibility filter PVNO integer Picture version number PWALLT real integer Ppoint wall thickness PWAS string(1000) Percentage wastage factor PWID string(1000) Width / Wall thickness PWWFAC real Powder way factor PX string(1000) Cartesian X position PXBS string(1000) Inclination of bottom surface to local X axis PXLE string(1000) X length PXTS string(1000) Inclination of top surface to local X axis PY string(1000) Cartesian Y position PYBS string(1000) Inclination of bottom surface to local Y axis PYLE string(1000) Y length PYTS string(1000) Inclination of top surface to local Y axis PZ string(1000) Cartesian Z position PZAXI string(30) Alignment axial direction PZDIR dir integer Ppoint alignment direction PZLE string(1000) Z length QALLSI integer AllocSize QMXUPT integer MaxUserPtr QNELEM integer QNoElem QOBJSI integer ObjectSize QTYPE word Type of question QUACD integer Quality code QUAL integer Qualifier QUAN integer Quantity (always one!) QUAPAI string(26) Paint specification QUATXT string(26) Quality QUES word Question QUSEXP integer(250) question expression RADD real Default Radius value RADF real Radius attractor factor RADI real Radius RADISP real(10000) Radius Spacing RADL real(2) Radius limits (Min/Max) RADS logical Radius set flag - ignore Radius values if FALSE RAILHE real(15) Heights of rails measured from path RAILTR real(10000) Rail Trim RANANG real(32) elemtype Range of available angles for bends and elbows RANEQUIP real Range of the nearest equipment RANRAD real(32) elemtype Range of available radii RATFAC real Rationalisation factor RATI real Pressure rating RATPOT string(15) Rationalisation post text RATPRE string(15) Rationalisation pre text RATTAL element(500) word Ratta list RATTAL element(500) word Rnode list RAWNAM string(500) Name only RAWPLA element Raw Plate RAWPRO string(26) Name of raw profile RCOD string Direction of region vertical on sheet RCOF pos Rough centre of gravity RCOU integer Number of rules on element RDEF real(3) Port rotation flexibility defaults REACT string(1000) Reactance READONLY logical Read only REALEV real Real evaluation REALXP integer(500) Real expression RECOMM string(256) Release to 3D comment REDATE string(12) Release to 3D date REDREF element Reducer table reference REDTYPE integer Reducer Type REDXRF element(500) Return reference from Reducer Table element to SPECs REF element Reference of the element REFA word Reference attribute used in ports REFI integer Reference array index REFL word(200) Types of elements (including UDETs) that can be pointed to by a reference attribute REFLCL logical True if reflected in CL REFLEVEL integer Reference Level REFMOD integer Reflection Mode REFSIZ integer Reference size REPCOU integer Rule Repeat Counter REPSEQ integer Sequence no. for template repeat element REPTXT string Reporter text used for element type REQUIRED logical Required RESIS string(1000) Resistance RESO real Model Resolution (distance) RESTAT integer Release to 3D status REUSER string(50) Release to 3D user REV integer Pipe Revision number REVDIR logical Reverse Direction flag REWIDTH real Reduced width RFLAG word Type of real answer NONE, SINGle, RANGe or MULTi RFLF real(3) Rotational spring values RGBCOL real(3) RGB colour vector RHOST string(120) Host computer name or IP address of remote machine RINE real(3) Rotational inertia vector RINS real Inside radius RISE real Tread Rise RLAC integer(500) Rule action array RLEX element(20) Array of references of special rules to exclude RLIM real(6) Rotation limits RLIN element(20) Array of references of special rules to include RLIS word(200) List of rules set RLLO integer(500) Rule logical array RLOC integer Branch Member Creation Status code (Router) RLSE integer(500) Rule selection array RMFL real(6) Rotational moment flexibility RMOF real(9) Rough moments of inertia RNAM string(120) Recipient name RNGCON element Rung Connection RNGOFF real Rung Offset RNREF element Route Node reference RNRIDF real Rung Rising Default RNRIMA real Rung Rising Minimum RNRIMI real Rung Rising Minimum RNTYPE word RNode Type ROBRRU element(500) Router Rules applying to a piping element or members ROLEREF element Access Control role references from ACR ROOMTY string(120) Room Type RORIEN logical True if repeat item is re- orientated upon rotation ROTN real(3) Rotation ROUT real Outside radius ROUTND element(100) Cable Preliminary route point ROUTRE element Route reference ROWCOL integer Row colour ROWCON integer Row colour number ROWNUM integer Pin row number ROWSTREF element Row linestyle Reference ROWSTY integer Row linestyle RPARM real(4) Rest plate parameters RPEN integer Pen for internal rows RPLCOD integer Rest plate code RPLNAM string(26) Rest plate name RPLNUM integer Number of rest plates RPLPOS real(4) Rest plate position RPLSET integer Rest plate set RPLTYP integer Rest plate type RPRE real Reference pressure RPRO real word Catalogue dataset property RPTX string(20) Text used when presenting the attribute to the user RRSF element Rep ruleset reference RSBOX real(6) Bounding box of RSO RSEQA integer(500) Sequence numbers for rule execution RSEQFA element(500) Rule sequence ref array for local names RSEQN integer Sequence number for rule execution RSESS string(120) integer Reason for creation of session RSET logical(3) Rotation limits set flag - ignore values if FALSE RSFFD integer Functional description on face RSFMC integer Material code on face RSFMS string(256) Material side on face RSFMT real Material thickness on face RSFSA logical Auto stiffening on face RSFSD string(256) Profile dim on face RSFSS string(256) Stiffener side on face RSFST integer Profile type on face RSFWT logical Watertight RSLBRA string(256) Bracket instance at limit RSLELE element Limiting element RSLPRE integer Profile end definition at limit RSPAN element(1000) Panel(s) defined on RSO RSPLN integer Principal plane of RSO RSRF real Rough surface area RSTYP integer Type of RSO RTEM real Reference temperature RTEX string(2000) R Text string RTYP string(12) Restraint type RULEER string(300) integer Text of "nth" rule error RULEMOD logical attr True if rule modified this session RULEMODC logical attr True if rule modified since comparison date RULEMODLIST word(500) integer List of rules modified since given session RULEMODLISTC word(500) List of rules modified since comparison date RULLIM real(6) Ruler limits RULRCO integer Ruler type code RULSET word(2000) List of rules set RULTCK integer Number of ticks between labelled ticks RUNGS integer Number of rungs RUNGSP real Rung Spacing RUSE integer True if PPROP/DPROP to be used as an RPROP in geomset/pointset attribute expression RVAU string(1000) Revision author RVDT string(12) Date of revision RVOL real Rough gross volume RVSN string(1000) Revision number RVTM string(120) Time of revision RWDOWN integer(2) Table linking RWELD elements to design WELD elements RWDOWN element Reference of associated WELD of RWELD element RWEI real Rough weight RWIDTH real Rung Width S real Position southing SAFC integer Safety class SAVDIR dir Cached direction SAVPOS pos Cached position SBRA element(10) SBOLT references SBRP element SBFR to RPLA reference link (Router) SCAL integer DRAFT user defined symbol scale factor SCALI real(500) ADP main view allowable scale list SCALIN logical Drafting symbol link scaling flag SCALPH logical ALPHA/NOALPHA flag SCAREF element(10) Area shape reference SCBREF element(50) Schematic element back reference SCDELI string(50) Delimiter SCDIGIT integer Digits SCEIRE element(60) Enhanced instrument relationship SCELOR element(20) Enhanced instrumentation loop reference array for schematic elements SCGTYP string(50) Schematic nozzle gtype SCHED string(10) Piping Schedule SCHELE element Schematic head element SCHEME string Scheme name SCHFF integer Schematic file format SCHLNK element Connectivity Schematic Link SCHTYP integer Schematic type SCIERTYPE word(60) Instrument enhanced reference type SCIIRE element(50) Instrument to instrument reference SCIIRTYPE word(50) Instrument to instrument reference type SCIPRE element(50) Instrument process reference SCIPRTYPE word(50) Instrument process reference type SCIREF element(10) Instrument reference SCIREL element(50) Instrument relationship SCIRLTYPE word(50) Instrument relationship type SCIRTY word(10) Instrument reference type SCLORE element(10) Instrumentation loop reference array for schematic elements SCOD string(3) Isodraft Compipe: Short code SCOPEREF element Access Control scope references from ACR SCOSEL integer(500) Access Control scope SCOSLX integer(500) Access Control scope SCPANA string(120) Schematic page name SCPATY word Schematic page type SCQUAN integer Quantity SCRAPT real Total scrap of raw plate area SCRAPU real Total scrap of used raw plate area SCREF element Schematic element reference SCSTYP string(257) Schematic stype SCSYSD element(500) System reference array for schematic diagrams SCSYSF element(10) System reference array for schematic elements SCTDIR dir Section Direction SCTELE element Schematic tail element SDISTA real Vertical Distance of Start SDTH real(3) Saddle thickness SDTINT integer(2) Splitting date SDTTXT string(22) Splitting date SECTYP string(120) Gpart Secondary type SEGE pos Segment end point position SEGS pos Segment start point position SENS string Rotational sense SEQU integer Sequence Position in Member List SESCLA integer Session Of Claim SESSC string(120) integer Comment for specified session SESSCA integer(2000) List of pairs of DB number, last session number for all referenced DBs SESSCH integer(2000) As for SESSCA, but searches all descendants for referenced DBs SESSD string(120) integer Date of specified Session SESSM integer attr Session Of Last Modification SESSNO integer Current opened Session SESSU string(120) integer User creating specified session SETDATE string(120) Set Date SEXPND element(10000) All descendant elements in secondary hierarchy SFCODE integer Stiffener Code SFLIMI word Spooling limits SFOR real(3) Start force vector component SFREF element Return reference from piping component or leave tube to spool or field element SHAP string(1000) Shape modulus SHFALG real Shrinkage factor along main direction SHFPRP real Shrinkage factor perpendicular to main direction SHFSEA real Shrinkage factor for seams perp. to main direction SHIPNO string(80) Ship number SHIPX string(20) Ship X position SHIPY string(20) Ship Y position SHIPZ string(20) Ship Z position SHOC real(3) Shock load vector SHOP logical Shop/Site flag SHOPRI logical Shop Primer SHPSYM string(40) Shape symbol text SHPUV pos Point defining shrinkage SHRF element Reference to associated sheet or library SHTNUM integer Sheet Number SHVUV dir Vector defining shrinkage SIF real(3) Stress intensification factor SIGF integer Significant figures SIGREF element Significant point reference SITEM element Reference from secondary hierarchy SIZE real(2) Sheet/region size SIZEDB integer Size of DB SJUS word Surface justification for PALJs SKEY string(4) Symbol key SKEYSCALE integer Universal SKEY scale factor SLENGTH real Side length SLOPEF logical SLOPEF (True if its a sloping wall else step change) SLOREF element Pipe slope reference SLRAP element(500) Sorted list of RATTA after POINTR SLRBP element(500) Sorted list of RATTA before POINTR SMAX integer Maximum spool number in current spool drawing SMEMB element(10000) Immediate members in secondary hierarchy SMNO integer SMODU number SMOD string Sectioning mode SMOM real(3) Start moment component SOLFILLED logical Solid Filled Flag SORF element Source reference (for automatic application) SOUR string(1000) Source macro SPBREF element Reference to boundary element SPECIF logical True if outer panel contour on PS/SB are different SPIN string(4) DRAFT user defined spindle symbol/skey name SPINRE element Reference to external inventory element SPKBRK logical ATTA flag to treat as a real element SPKCHG element flag to show where a spec change occurs in a branch SPKDI real Proportional distance of start point along Pline SPLA string Name of spigot plate SPLATE word Section plate SPLH string(120) Old spooler head tube spool number SPLMEM element(1500) Spooling table attribute on SPOOL or FIELD elements SPLN string(120) Old spooler component spool number SPLNUM integer Spool number SPLP string(120) Spool number prefix SPLPARENT element(500) elemtype Branches referenced by a SPLDRG, SPOOL or FIELD SPLT string(120) Old spooler tube spool number SPLTBL integer(2000) Table linking SPOOL & FIELD elements to piping components SPLVOLUME real(3) Volume of a SPOOL element SPMA real word Spec angle maximum answer SPMACC string(25) Access authorization code SPMACD string(75) Access authorization description SPMALL real Structural Allowance SPMAOF real Offset AFT SPMARA real Area of face SPMARE real Area of face SPMATP integer Type of space arrangement SPMBB real(6) Bounding box SPMBIN integer Boundary identification number SPMBNA string(80) Boundary name SPMBOF real Offset BOT SPMBOX real(6) Bounding box SPMBR element Bounding reference SPMCAS real Calculated steel paint area of space contents SPMCDE string(75) Content description SPMCFA real Floor area SPMCLI word(2000) List of customer attributes for space SPMCOL integer Colour SPMCOS real(3) Calculated centre of steel structure SPMCOV pos Centre of Volume SPMCTY string(25) Content type code SPMCWB real Calculated length of butt weld SPMCWC real Calculated Weight of space Contents SPMCWL real Calculated length of fillet weld SPMCWS real Calculated Weight of steel structure SPMDE real Density SPMEAS real Estimated steel paint area of space contents SPMEHC real Estimated HVAC Capacity SPMEN string(26) Envelop name SPMEPC real Estimated Power Consumption SPMEWB real Estimated length of butt weld SPMEWC real Estimated Weight of space Contents SPMEWL real Estimated length of fillet weld SPMEWS real Estimated weight of steel structure SPMFAR real Face area SPMFCL string(20) Fire class SPMFLW real Full load weight SPMFOF real Offset FWD SPMFST integer Face state SPMHSN string(26) Hull surface name SPMLSC string(25) Space Category SPMMVO real Total (moulded) volume SPMNBI integer Next boundary identification number SPMNOC string(25) Noise category code SPMNOD string(75) Noise category description SPMNVO real Net volume SPMPED real Permeability Damage SPMPER real Permeability SPMPOF real Offset PS SPMPP real(5) Precise properties SPMPU string(25) Purpose code SPMRDH real Required deck height SPMRFA real Required floor area SPMRSE string(25) Required service code SPMRSN string(26) Reference surface name SPMRTE element Reference to envelop space SPMSAC string(25) Safety category code SPMSAD string(75) Safety category description SPMSAN string(80) Space arrangement name SPMSBD element(500) Space boundary definitions SPMSEC string(25) Security classification code SPMSED string(75) Security classification description SPMSFI integer Subface identification number SPMSFP element Returns the space that contains the given point SPMSOF real Offset SB SPMSS integer Space state SPMSTP integer User defined subtype SPMSWT integer Type of space world SPMTHC string(25) Thermal insulation code SPMTHD string(75) Thermal insulation description SPMTIC string(25) Compartment tightness code SPMTID string(75) Compartment tightness description SPMTOF real Offset TOP SPMTOL integer Type of limits SPMTYP string(20) Type of space world as enumerated SPMVOI integer Space void marker SPOONUMBER string(120) Spool number including spool prefix SPOW element Reference of SPEC owning SPCO of branch members SPPOSN integer Position number of spigot plate SPPURP word Special purpose table attribute SPRA real word Spec angle answer SPRB real word Spec bore answer SPRE element Component spec reference SPSF element Sheet pointset reference SPSP string(2) Old spooler spool prefix SPTYPE word Type of element to be selected SPWD string word Spec text answer SQCURR integer Current value in sequence SQMAX integer Maximum value of sequence SQNAME string(50) Name of sequence SQSTEP integer Increments in sequence SQWRAP logical True if wrap around in sequence is allowed SREF string(12) Source reference SREL integer Start releases (packed) SREVAY element(50) Sheet revisions array SRFTRE element Reference to a SRFTRT element SRTP integer Sorting priority for dimensions SSLENGTH real Second side length SSPLIT logical Spool Split STACOM string(1000) Comment to the current status set STAELE real Start Elevation STAN real Start angle STAP real Length of arrive straight tube STAPOINT integer Cable Start connection point STAREF element Cable Start reference STASUS logical Current status suspended STCD string(100) Symbol Code STDEFREF element Status definition STEREF element(500) Stencil reference array for schematic elements STEX string(2000) S Text string STFC real Constant stretch factor STFP real Proportional stretch factor STINCD string(120) Inside surface treatment symbol code STINRF element Inside surface treatment reference STITL string(120) Sheet title STLE real Length of leave straight tube STLPOS element Status Element reference STLR element Steel Reference STLSF element Database reference STMF element Template selection pointer STOCKL real Stock Length STOUCD string(120) Outside Surface treatment symbol code STOURF element Outside surface treatment reference STPDBS element(5000) Stamps containing db STPSES integer(2000) Sessions used in at least one stamp STPUV pos Start point STRCON string(120) Stair Configuration STRE real Spot value of stress STREAT string(26) Surface treatment STREV string(120) String value evaluation STRSTD string(120) Stair Standard STRXP integer(500) String expression STRXPL logical True if surface treatment explicitly defined STSESS integer Database session number STSP element Structural specification STVASD element(500) Status types eligible STVCOM string element Status comment STVDEMOTE element Demote Status Value STVDSC string element Status description STVHCO string element Status held comment STVHOL logical element Current status held STVLNK element element Status value Reference STVLSK element(500) Status Link Elements STVLST element(500) Statuses assigned STVNAM string element Status value name STVNUM integer element Status value STVPROMOTE element Promote Status Value STVREF element Value Ref STVSUS logical element Current status held STVTRV element(500) Valid Transitions STVUNR element(500) Unresolved Status refs STVUSD element(10000) Elements having this status value STVVAL element element Status value Reference STYF element Rep style reference STYP string SPECON type question STYPDB string DB sub type SUFFIX string(120) Suffix SUPP string(120) Supplier Name SUPR element SUPREF SURF string(120) Surface Preparation SURMAT string(100) Surface Material SURNOR dir pos, dir Surface Normal SURPNT pos pos, dir Surface Point SURPRE string(100) Surface Preparation SVASPLANE logical Hull symbolic view as plane Y/N SVASSEMBLIES element(100) Hull symbolic view assembly elements SVAUTO logical Hull symbolic view auto Y/N SVBLEXCLUDE logical Hull symbolic view exclude blocks Y/N SVBLOCKS element(100) Hull symbolic view block elements SVCAX logical Hull symbolic view coord axis Y/N SVCOMNO integer Hull symbolic view component number SVCOMTYPE integer Hull symbolic view component type SVCROSSSYM logical Hull symbolic view cross sect symbol Y/N SVCURTYPE integer Hull symbolic view curve type SVCURVES element(100) Hull symbolic view curve elements SVDBEFORE string(20) Hull symbolic view depth before SVDBEHIND string(20) Hull symbolic view depth behind SVDRACCOM logical Hull symbolic view draw accommodation Y/N SVDRAINTERS logical Hull symbolic view draw inters Y/N SVDRAP logical Hull symbolic view draw plane V SVDRCWAY logical Hull symbolic view draw cableway Y/N SVDREQUIP logical Hull symbolic view draw equip Y/N SVDRPIPE logical Hull symbolic view draw pipe Y/N SVDRPVOL logical Hull symbolic view draw pvol Y/N SVDRSTRUCT logical Hull symbolic view draw structure Y/N SVDRVENT logical Hull symbolic view draw ventilation Y/N SVLOOKING integer Hull symbolic view looking direction SVLXMAX string(20) Hull symbolic view xmax SVLXMIN string(20) Hull symbolic view xmin SVLYMAX string(20) Hull symbolic view ymax SVLYMIN string(20) Hull symbolic view ymin SVLZMAX string(20) Hull symbolic view zmax SVLZMIN string(20) Hull symbolic view zmin SVNAME string(1000) Hull symbolic view name SVPANELS element(100) Hull symbolic view panel elements SVPLEXCLUDE logical Hull symbolic view exclude panels Y/N SVPLTYPE integer Hull symbolic view plane type SVPLXORIGIN string(20) Hull symbolic view x1 SVPLXUAXIS string(20) Hull symbolic view x2 SVPLXVAXIS string(20) Hull symbolic view x3 SVPLYORIGIN string(20) Hull symbolic view y1 SVPLYUAXIS string(20) Hull symbolic view y2 SVPLYVAXIS string(20) Hull symbolic view y3 SVPLZORIGIN string(20) Hull symbolic view z1 SVPLZUAXIS string(20) Hull symbolic view z2 SVPLZVAXIS string(20) Hull symbolic view z3 SVPNAM string(1000) Hull symbolic view pan name SVPONLY logical Hull symbolic view pan only SVPOSCOAXIS string(20) Hull symbolic view coord axis pos SVREFLECT logical Hull symbolic view reflect Y/N SVRSO logical Hull symbolic view RSO Y/N SVSCALE real Hull symbolic view scale SVSHPROFILE logical Hull symbolic view profile Y/N SVSHSEAM logical Hull symbolic view shell seam Y/N SVSHTHICK logical Hull symbolic view shell thickness Y/N SVTYPE integer Hull symbolic view type SVWAY element(50) Sheet Views array SWING word Swing SYLBTA word SYLBTAble attribute SYMBFG logical Symbol flag SYMELE element Reference to element on other side of CL (unset for non-symmetric) SYMGRO string(120) Symbol Group SYMLNS integer Side of direction vector SYMM integer Symmetry code SYMNAM string(120) Symbol Name SYMXYZ dir Vector along symmetry line SYSZ real Symbol size (uniform scaling) SYTBOK logical SYLBTA attribute updated flag SZDI real Start load point in section TABANS real(10) Tabular answers TAGCD integer Tag code TAGCDS integer(25) Tag codes TAGNMS integer(25) Tag numbers TAGNUM integer Tag number TANGLE real Tile Angle TANGOF real Tangent offset TANS string(1024) Text answer for text styp in spec TARF element Target reference TATYPE string(10) Text answer type TBID integer Tribon ID TBNAME string(25) TbName TBOR real Tail bore TCAT element Trace catalogue reference TCDD string(250) word Current design property default value TCDP string(250) word Current design property value TCOD string Hashed origin code TCON word Tail connection type TCORRO real Tail Corrosion TCREF element(10) Tail connections TCTL real True cut length TDEF string(1024) Text default for text styp in spec TDET element Trace detail text reference TDIR dir Tail direction TDMF element(2) ISODRAFT Reference Dimension attribute TDMT word(2) ISODRAFT Reference Dimension attribute TDPR real word Template design dataset property TDRT string(2000) Trace detail RTEXT TDST string(2000) Trace detail STEXT TDTT string(2000) Trace detail TTEXT TEAMLS element(1000) List of TEAMs to which USER belongs TEASTA word Access Control team status TEMF element Team reference TEMP real Temperature TEND string Connection at other end of TREF (HEAD or TAIL) TEQDES string(120) To Equipment Description TESTEV logical Result of constraint test evaluation TESTXP integer(500) Logical Expression TEXIST logical True if component has TUBI. Always true for offline bends. TFDP element word Template design dataset property TGEOM logical True if component has TUBI geometry TGRA real Pipework temperature gradient THERMA string(104) Thermal category THICKNESS real Thickness THPO pos Point through which viewing TIERHE real(15) Heights of trays measured from path TIMEEND integer End time of COMMS window TIMEINTERVAL integer COMMS retry time interval TIMEOUTNUMBER integer COMMS max retry count TIMER string(120) Frequency of DB propagation TIMESTART integer Start time of COMMS window TIMFAC real Pathtime time factor TIMPET string(15) Time factor pre text TIMPOT string(15) Time factor post text TITL string(1000) Title TLCONN element(500) List of elements connected to branch tail TLIN logical True length indicator TLREF element(500) List of attachment connected to attachment TMAT element Trace material text reference TMAV real Average temperature TMDWG string(120) AutoCAD template name TMMA real Maximum temperature TMMI real Minimum temperature TMPR element Template reference from SPCO TMRF element Template reference TMRMASTER element Template Repeat Master Duplicate Element TMROWNER element Template Repeat Owning Element TMRREF element Template Repeat Element Reference TMRRULE integer(500) Template Repeat Rule TMRXREF element(500) Return reference from TMRREL element to repeat elements TMXT string(2000) Trace material XTEXT TMYT string(2000) Trace material YTEXT TMZT string(2000) Trace material ZTEXT TOFFT real Tail offset TOPOLOGY string(120) Branch topology TOTALT real Total machine time for a nested plate TOTLAB real Total label pathtime TOTLEN real Total length TOTT real(2) Total pathtime TOTTI real(2) Total pathtime, I-bevel TOTTX real(2) Total pathtime, X-bevel TOTTY real(2) Total pathtime, Y-bevel TPAR real(30) Trace catalogue component parameters TPEN integer Text pen TPLFRR element(10000) Topology references TPON integer TO port number TPOS pos Tail position TPOSE real Easting of tail position TPOSN real Northing of tail position TPOSU real Upping of tail position TPREF element Tail point reference TPRESS real TestPressure TPVAL string(1000) Task parameter name TQUAL string(1024) Text qualifier in spec or sele TQUES string(1024) Text question in spec or sele TRANS real(12) Local transformation matrix TRAYH real Tray height TRAYOW real Tray other width TRAYRW real Tray Reduce Width TRAYSW real Tray side width TRAYW real Tray Width TRCG logical DRAFT user defined symbol trace flag TRCLIN word Trace line TREATP element Tread type TREDOV real Tread Overlap TREF element Tail reference TRGENA logical Initial Value TRIMCE integer(10000) Array of Trimmed Cells TRIMTY word CTWALL TRIM TYPE TRSF element Tag ruleset reference TRUN real Truncation value (+ve) or percentage (-ve) TSFBR logical Spooling marker for leave tube TSIZ real Terminator size TSLEN real Total suspension length TSPE element Tracing spec reference TSPR element Trace specification component reference TTEX string(2000) T Text string TTFACE string(32) TrueType font face name TTFDES string(128) TrueType font description TTFENA logical TrueType fonts enabled flag TTFIND integer TrueType font index TTYP word Template type TUCL real Tube centreline length of branch TUFG logical Tubing flag TUFL logical Tube flag TULE real Tube length of branch TVIS logical Top visibility flag TWALLT real Tail wall thickness TWIDTH real Tread Width TWIST logical True if twisted TWLEN real Total weld length TWRF element Tail Working Point (Router) TWSTAN real Twist angle TXALIGN string Text alignment TXAREA real Total Cableway X-area TXCOLO integer Text colour TXCONU integer Text colour number TXSPLI logical Text splitting flag TXSTRI string(1000) Text String for enhanced LineStyles TYNU integer Number type TYPE word Type of the element, ignoring UDET, truncated to 4 or 6 characters TYPEA string(10) TYPEA TYPEB string(10) TYPEB TYPECD integer Type code TYPECE integer Type code TYPEDB string(6) DB type TYPEXPRESSION string(4000) Type Expression TYPEXTYPE string(60) Type expression type TYPINC logical Type is inclusive TYSEQU integer Type Sequence Number U real Position upping UAEXSS real User Excess Arrive UALL logical UALL UAREA real Used area UBULG real Used bulge factor for curve geometry UCAT string(50) Category on forms UCOD integer Units code UCODB integer Units code bore UCODD integer Units code distance UCONN logical True if the UDA value should appear on the reference list form UCURTYP word Used curve type UCUTDI dir Upper Extension Cutting Direction UDACPY element UDA copy UDALIS word(2000) List of UDAs UDASET word(2000) List of UDAs set UDATLS word(200) List of attributes for UDET UDETCHECK string(120) Report from UDET check on element UDHLIST word(200) Attributes hidden on elements of this user- defined element type UDIRECTION dir Up axis direction UDMLIST word(200) List of allowed member types UDNA string(50) User defined name UDOLIST word(200) List of allowed owner types UDPEND word(200) list of attributes that this attribute depends on UEEXSS real User End Excess UEXTNS real Upper Extension Length UGOING real(10) Upper Tread Going UHIDE logical Set true to hide attribute on forms UHYPER logical Set true to treat attribute value as a named link to an external resource UIWE string(1000) Unit insulation weight UKEY integer UDA key - internal unique system identifier ULEN integer Length of data or text ULVOPT logical Determines if UDA valid values or range limit is optional UMAX real Maximum value UMIN real Minimum value UNAM string(12) Name of user UNDERL logical Underling flag UPDCB string(500) ADP update callback UPLLEN real Used raw plate length UPPING pos Upping part expressed as a position UPPREF element References to upper exit level UPRLEN real Raw profile used length UPROTE logical Set true to disallow viewing the attribute in a protected database UPSEUD logical Set true to calculate attribute value rather than store it in a database. User code must be provided URADI real Used radius for curve geometry UREF element Units reference URISE real(10) Upper Tread Rise URL string(1024) URL USCCOG pos User derived centre of gravity position USCLHI element(5000) Elements in descendant hierarchy claimed to this user USCWCO pos User derived wet centre of gravity position USCWEI real Derived value for user weight USCWWE real Derived value for user wet weight USEF element User reference USERC string(120) User name of user claiming element USERLS element(1000) List of USERs belonging to TEAM USERM string(120) attr User making last modification USESS string(120) integer User creating session USNCLH element(5000) Elements in descendant hierarchy not claimed to this user USRCOG integer(500) User centre of gravity position USRLI element(50) Valid users for given user login USRWCO integer(500) User wet centre of gravity position USRWEI integer(500) User entered weight value USRWWE integer(500) User entered wet weight value USYSTY word Name of the system attribute UTEAMS element(200) Teams that will see a hidden attribute UTYP word Type of attribute value UUID string(36) Universally unique identifier UUIDAR integer(4) Universally unique identifier, stored array UUIDREF element(500) word Universally unique identifier references UUNI string(20) Units of attribute values (bore/distance/text) UVVAL string(500) Valid value for UDA UWEI string(1000) Unit pipe weight UWGHT real Used weight UWIDTH real Used width UWMTXT string(120) User weight Manager text UWP pos Upper Working Point VALARR element(50) Valid Status Values VALIDV string(1000) Valid value expression for VVALUE elements VALNAM string(50) Local Name of a Status Value VALNUM integer Numerical representation of a Status Value VALREF element Status Value reference VALRUL string(1000) Valid rule expression to test VALIDV attributes of VVALUE elements VALTEX string(120) Textual representation of a Status Value VANGLE real Angle from vertical VBEVEL logical True if part has bevel type V VCOMPD string(50) View Comparison Date VCOMPS element View Comparison Stamp VDISTA real Vertical Distance VDPOS pos Dimension line/arc position VDTINT integer(2) Verification date VDTTXT string(22) Verification date text VENID string(120) LMI Vendor ID VERTDI logical VERTDI (true if Z axe is vertical ) VGAP real View gap length VHEIGHT real Volume height VIRF logical Virtual Flag VISF string(73) Visio filename VLIM real(6) View limits VMAR real ADP view margins VMCIAR integer(10) VM Component Int Array VMCRAR real(10) VM Component Real Array VMDRPDMS logical VM Draw anno using pdms engine Y/N VMFCFB logical VM Fill Colour From Border Y/N VMFLAY integer VM Fillstyle Layer VMGLAY integer VM Geometry Layer VMTASP real VM text aspect VMTSLA real VM text slant (degrees) VMUSYS integer VM Fillstyle Unit System VNREF element VNOTE reference - special attribute for use by ADP VOLTAC string(1000) Voltage AC VOLTDC string(1000) Voltage DC VRADI real Cableway radius VRAT real(2) View ratio VREG real(4) View region VSCA real Viewing scale - scales projected view VSHAPE integer Volume shape VTITL string(120) View title VTYP string Type of design view VVOL real(6) View volume VWIDT real Volume width VWLIMI real(6) View Limits - special attribute for use by ADP VWREFA element(20) View reference array - special attribute for use by ADP VXREF element(500) Vertex reference array W real Position westing WALLTH real Tube wall thickness WAMA real Maximum water level WANS word(100) Word answers WATERT logical Water Tight WATTIM real Water cleaning time WBORE real Bore on IWELD/RWELD WCANG real Weld connection angle WCOM string(26) Weld comment WDBNA string Working DB name WDESP word(100) Design parameters as words WDIA string(1000) Wind diameter modulus WEFA real Weight multiplier WEIG real(3) Weighting value WELDDP real Welding depth WELDMC element Welding Machine Reference WESUSP real Weld end suspension WHOLEC real Array of Whole Cells WIANG real Weld inclination angle WIDARR real(10) Width array WIDT real Width WIFA real Wind multiplier WJPOS pos Implied weld position WJUSL word Wall Justification Line WLDC integer Weld Code WLDN integer Weld number WLDP string(4) Weld number prefix WLDPOS string(26) Welding position WLDREF element integer Return reference from Ppoint or WELD to IWELD or RWELD element WLEGL real Weld leg length WLEN real Weld length WMAX integer Maximum weld number in current spool drawing WNAM string(26) Weld name WNLAY integer Number of weld layers WORI ori World orientation WORPOS pos World position WPAR word(100) Parameters as a word WPRE real Wind pressure WPROC string(26) Welding process WRANG real Weld rotation angle WSHOP logical Weld shop/site flag on IWELD/RWELD WSPEC element Weld specification on IWELD/RWELD WSPROC string(26) Welding standard process WSSUSP real Weld start suspension WTCOM string(300) Weld table comment WTEREF element integer Wall thickness element reference WTHICK real Wall thickness WTHREF element Wall thickness table reference WTOL string(1000) Wall thickness tolerance / Weight tolerance WTORCH dir Weld torch vector WTPROC string(26) Welding test procedure WTRANS real(12) Transformation matrix to world WTSTAT string(26) Weld table status WVOL real(6) Enclosing box volume in world coordinates XAMANG real Cross section along mounting angle XAREA string(1000) Cross sectional area XBEVEL logical True if part has bevel type X XBOT real Bottom X length XBSH real X bottom shear: inclination of bottom face to local X axis XFTPT pos Cross section foot point XINCL real Cross section inclination angle XLEN real X length XOFF real X-offset XRLIST element(10000) elemtype List distributed attributes XRLSTT word(2000) elemtype List distributed attributes XRPNTR element Distributed Attributes reference XRQCNT integer elemtype Get distributed attributes element count XRQELE element elemtype, Get distributed attributes integer element XRSTRT element Distributed Attributes reference XTEX string(2000) X text XTHK real Cross section thickness XTOP real Top X length XTPPT pos Cross section top point XTRA real Extra length requirement for BOLTS XTSH real X top shear: inclination of top face to local X axis XXMANG real Cross section cross mounting angle XXXDIR dir Direction Test attribute XXXORI ori Orientation Test attribute XXXPOS pos Position Test attribute XYOFFS real(2) XY offset XYPS pos 2D Position XYSC real(2) Label XY size YBEVEL logical True if part has bevel type Y YBOT real Bottom Y length YBSH real Y bottom shear: inclination of bottom face to local Y axis YDIR dir Preferred Y axis direction YLEN real Y length YOFF real Y-offset YOUN real Spot value of Youngs modulus YTEX string(2000) Y text YTOP real Top Y length YTSH real Y top shear: inclination of top face to local Y axis ZDIR dir Additional axis direction ZDIS real Position in section ZLEN real Z length ZOFF real Z-offset ZTEX string(2000) Z text
Copyright 1974 to current year. AVEVA Solutions Limited and its