Power Calculation – AKASAKA (6UEC45LSE/7470 KW @130 RPM
#Engine Output (KW) = K x Ne x [Net Cal. Value of fuel oil in ship (KJ/Kg) x Sp.Gravity of ship oil at engine inlet temp. / Net Cal. value of fuel in shop trial (e.g. 42550KJ/Kg) x Sp.Gravity of fuel oil in shop trial (e.g. 0.8641)] K = Torque factor obtained from torque factor chart (depends on load indicator & propeller margin), propeller margin for particular engine is 0.9835 @ 5 %. So, K = Load Indicator x Propeller margin Ne= Ships RPM