Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 83

DESIGN CALCULATION

FOR

MODULE MOUNTING STRUCTURE (MMS)


ON 1000KWp GRID FIXED TILT TYPE SOLAR
MES, RAYANG ARUNACHAL PRADESH

PROJECT

1MW AC GRID TIED SOLAR PANEL MES

Document No: RT_001-2018-MES-CE-01_MMS_R1


1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

CLIENT

MES , RAYANG ,ARUNACHAL PRADESH

EPC CONTRACTOR

M/S PURABANCHAL SUPPLIERS AND CONTRACTOR

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 2 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

1 02/07/18 For Approval

0 28/06/18 For Approval

REV INTLS SGN INTLS SGN INTLS SGN


DATE STATUS
NO PRPD. BY CHKD. BY APPR. BY

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 3 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

CONTENTS

1. GENERAL ........................................................................................................... 4

1.1. SCOPE ............................................................................................................... 5

1.2. UNIT OF MEASUREMENTS .............................................................................. 5

1.3. CODES AND REFERENCES .............................................................................. 5

1.4. MATERIAL PROPERTIES .................................................................................. 6

1.5. PLANT SITE INFORMATION ............................................................................ 6

1.6. SOFTWARE REFERENCE .................................................................................. 7

2. DESCRIPTION OF STRUCTURE & GEOMETRY .................................................. 7

3. DESIGN PHILOSOPHY ........................................................................................ 7

4. LOAD CALCULATIONS....................................................................................... 8

4.1. DEAD LOAD ..................................................................................................... 8

4.2. WIND LOAD CALCULATION FOR PURLIN STRUCTURES ............................. 8

4.3. LOAD COMBINATIONS .................................................................................. 10

5. DEFLECTION CALCULATION FOR DOUBLE LEGError! Bookmark not defined.

ANNEXURE – A: STAAD INPUT FILE

ANNEXURE –B: STAAD Output

1. GENERAL

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 4 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

1.1. SCOPE

This document covers the Analysis of Super Structure of Module mounting structure of 1 MW to be
installed solar panel at Connected roof top SPV power plant at Arunachal Pradesh, MES.

1.2. UNIT OF MEASUREMENTS

The Unit of measurements used in analysis shall be of SI.

1.3. CODES AND REFERENCES


The following codes and references have been referred: for the design of Module mounting Structure.

Indian Standard Codes

1 IS 456 – 2000 Plain and Reinforced Concrete –Code of Practice

IS 875: Part 1 & Code of practice for the design loads for buildings and
2
2 structures-

IS 875: Part Code of practice for the design loads for buildings and
3
3:2015 structures- Wind Loads

4 IS 800 : 1984 Code of practice for general construction in steel

5 IS 801 : 1975 Code of practice for cold formed steel

Hot Dip Zinc Coating on Structural Steel and Other Allied


6 IS-4759:1996
Products –Specification

7 IS: 2062:2006 Hot Rolled Low ,Medium and High Tensile Structural Steel

Hexagon Head Bolts Screws and Nuts of Products grade A and


8 IS:1364:2002
B

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 5 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

9 IS:1893:2002 Criteria For Earthquake Resistant Design Of Structures

10 IS:2911 Design and construction of bored cast in situ

Plain and Reinforced Concrete - Code of Practice is an Indian


11 IS 456:2000 Standard code of practice for general structural use of plain
and reinforced concrete

FASTENERS — THREADED STEEL FASTENERS — STEP


12 IS:10238:2001
BOLTS FOR STEEL STRUCTURES — SPECIFICATION

1.4. MATERIAL PROPERTIES

Material Property Value Unit

Concrete, Density 25 kN/cum


M25 Characteristic Strength 25 N/sq mm
Specification IS 456

Structural Density 78.5 kN/cum


Steel
Characteristic Strength 350 (cold formed) N/sq.mm

Modulus of Elasticity 210000 N/sq.mm

Specification IS 2062

1.5. PLANT SITE INFORMATION

Location of sites : Rayang, Arunachal Pradesh


Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 6 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Basic wind speed : 180 km/hr = 50 m/s

1.6. SOFTWARE REFERENCE

STAAD - Pro, Research Engineers Inc., Berkely, USA

In-house developed Ms-Excel programs The above software packages are used for the structural
analysis and the same are carried out in this document.

2. DESCRIPTION OF STRUCTURE & GEOMETRY

The Module mounting structure is a Steel frame structure. With a tilt of an angle 20o towards south. It is
supporting crystalline modules.

3D view of Structure Geometry

3. DESIGN PHILOSOPHY

The module mounting structure is designed using the structural analysis software package STAADPRO. The
analysis is performed for self-weight of structural members, other Dead Load on the members, Equipment
Loads, Wind loads. Various possible load combinations of the above loads are listed in section 4.3.
Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 7 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Structural Configuration & Modeling Assumptions:

1. The rafter and columns are rigidly connected to each other in transverse direction

2. Columns are fixed support at top and Fixed at bottom.

3. Wind load is applied as per IS: 875-Part-III by using pressure coefficient method.

4. LOAD CALCULATIONS

4.1. DEAD LOAD

Module – SRI SAVITR

Size - 1961 x 991 mm

Weight – 21.12 kg / module => Module is supported on Purlin

Length of Purlin = 10.2 m

UDL on purlin for 20 modules:

= 21.12*20/(4x10.2) = 10.353 Kg/m =10.353*(10/1000) = 0.104 KN/m

4.2. WIND LOAD CALCULATION FOR PURLIN STRUCTURES

BASIC WIND SPEED (Vb) - 180 km/hr

Risk Coefficient factor K1 – 0.90 (As per Table 1 considering 25 years design life of IS: 875 Part 3- 2015)

Factors for variation in height K2 – 1.0 (As per Table 2 of IS: 875 Part 3- 2015)

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 8 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

For Terrain category 2 and Class A

Factors for topography K3 - 1.0 (As per Clause 5.3.3.1 of IS : 875 Part 3- 2015)

Factors for topography K4 - 1.0 (As per Clause 6.3.4 of IS : 875 Part 3- 2015)

Design Wind Speed Vz = 50x0.9x1x1X1= 46 m/s

Design Wind pressure Pz : 0.6x452 = 881.82 N/sqm = 1.215 KN/sqm

Kd = Wind directionally factor 0.9 (as per IS 875 Part 3 :2015)

Ka = Area Averaging factor 0.9 Area = 10.2x 3.942 = 40.28, if A>25 Ka =0.9

Kc = combination factor 1.0

Pd = Kd x Ka x Kc x Pz = 0.9*0.9*1.0*1.215 = 984.15 N/sqm

I) WINDLOAD UPLIFT :

Module mounting structure is free Standing roof over dual vertical post. Refer Table 7 of IS 875 part 3

In IS 875 Part 3:2015 for solidity ratio Ɵ =0 for α =200

Cp = -1.3 (Considering even distribution of pressure)

Length of Purlin = 10.2 m,

Upward wind force for 20 module: CpxAmxPd = 1.3x1.961x0.991x0.984x20 = 49.375 KN.

UDL on Purlin : = 49.375/(4x10.2) = 1.210 KN/m

II) WINDLOAD IN +X DIRECTION :

Column Leg 150x50x20x5 = 0.15*0.984 = 0.1476 KN/m

Rafter 100x50x15x3.15 = 0.1*0.984 = 0.0984 KN/m

III) WINDLOAD IN +Z DIRECTION :

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 9 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Purlin 70x40x10x5 = 0.070*0.984 = 0.0689 KN/m

Column 150x50x20x5 = 0.050*0.984 = 0.0492 KN/m

IV) SEISMIC FORCES :

Seismic zone –V: IS 1893:2002: Criteria for Earthquake Resistant Design of Structures

V) WIND ZONE :

Wind Zone: V Wind speed: 180 Kmph

4.3. LOAD COMBINATIONS

The following load combinations are considered in the analysis and design of Module Mounting Structure.

LOAD COMB 8 1.5*DL

LOAD COMB 9 1.5*(DL+WLUP)

LOAD COMB 11 1.5*(DL+SIDEWAYS+X)

LOAD COMB 12 1.5*(DL+SIDEWAYS+Z)

LOAD COMB 13 1.5*(DL+SIDEWAYS-X)

LOAD COMB 14 1.5*(DL+SIDEWAYS-Z)

LOAD COMB 15 1.5*(DL+WIND UPLIFT+SIDEWAYS+X)

LOAD COMB 16 1.5*(DL+WIND UPLIFT+SIDEWAYS+Z)

LOAD COMB 17 1.5*(DL+WIND UPLIFT+SIDEWAYS-X)

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 10 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

LOAD COMB 18 1.5*(DL+WIND UPLIFT+SIDEWAYS-Z)

LOAD COMB 23 1.2*DL+1.2*WIND UPLIFT +WL+X

LOAD COMB 24 1.2*DL+1.2*WIND UPLIFT -WL+X

LOAD COMB 25 1.2*DL+1.2*WIND UPLIFT +WL+Z

LOAD COMB 26 1.2*DL+1.2*WIND UPLIFT -WL+Z

LOAD COMB 27 1.2*DL+1.2*EQ+X

LOAD COMB 28 1.2*DL+1.2*EQ+Z

LOAD COMB 29 1.2*DL+1.2*WIND UPLIFT +WL+Z

LOAD COMB 30 1.2*DL+1.2*WIND UPLIFT -WL+Z

LOAD COMB 52 1.5*(DL+EQ(+X)

LOAD COMB 53 1.5*(DL+EQZ)

LOAD COMB 54 DL*(0.9)+1.5*EQX

LOAD COMB 55 DL*(0.9)+1.5*EQZ

LOAD COMB 56 DL*(0.9)-1.5*EQX

LOAD COMB 57 DL*(0.9)-1.5*EQZ

 Factor of safety 1.5 has been considered in structural design.

5. STAAD INPUT - ANALYSIS & OUTPUT RESULT REPORT :

1. STAAD SPACE

INPUT FILE: MES_SHILLONG_20DEG.STD

2. START JOB INFORMATION

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 11 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

3. ENGINEER DATE 25-JULY-18

4. JOB NAME M/S PURABANCHAL SUPPLIERS AND CONTRACTOR

5. JOB CLIENT MES,RAYANG,ARUNACHAL PRADESH

6. JOB NO 1MW SOLAR PV PROJECT AT RAYANG ARUNACHAL PRADESH

7. END JOB INFORMATION

8. INPUT WIDTH 79

9. UNIT METER KN

10. JOINT COORDINATES

11. 113 0 1.20362 -1.12484; 114 2.8 1.20362 -1.12484; 117 -0.9 1.20362 -1.12484

12. 119 0 0.579625 -0.127121; 120 2.8 0.579625 -0.127121

13. 123 -0.9 0.579625 -0.127121; 183 0 1.71319 -1.94311; 184 2.8 1.71319 -1.94311

14. 187 0 0.305188 -1.94311; 188 2.8 0.305188 -1.94311; 198 2.8 0.454485 -1.94311

15. 199 0 0.454485 -1.94311; 260 0 1.629 -1.80829; 261 2.8 1.629 -1.808

16. 274 5.6 1.20362 -1.12484; 275 5.6 0.579625 -0.127121; 276 5.6 1.71319 -1.94311

17. 277 5.6 0.305188 -1.94311; 279 5.6 0.454485 -1.94311; 282 5.6 1.629 -1.808

18. 295 8.4 1.20362 -1.12484; 296 8.4 0.579625 -0.127121; 297 8.4 1.71319 -1.94311

19. 298 8.4 0.305188 -1.94311; 300 8.4 0.454485 -1.94311; 303 8.4 1.629 -1.808

20. 313 9.3 1.20362 -1.12484; 314 9.3 0.579625 -0.127121; 315 9.3 1.629 -1.808

21. 318 5.6 2.27536 -2.84258; 319 8.4 2.27536 -2.84258; 320 0 0.563169 -0.100849

22. 321 2.8 0.563169 -0.100849; 322 5.6 0.563169 -0.100849

23. 323 8.4 0.563169 -0.100849; 324 0 2.25204 -2.80526; 325 2.8 2.25204 -2.80526

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 12 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

24. 326 5.6 2.25204 -2.80526; 327 8.4 2.25204 -2.80526; 328 -0.9 2.25204 -2.80526

25. 335 9.3 2.25204 -2.80526; 336 0 2.26794 -2.8307; 337 2.8 2.26794 -2.8307

26. 338 5.6 2.26794 -2.8307; 339 8.4 2.26794 -2.8307; 340 -0.9 1.629 -1.80829

27. 341 1.4 2.25204 -2.80526; 342 1.4 1.629 -1.80815; 343 1.4 1.20362 -1.12484

28. 344 1.4 0.579625 -0.127121; 345 4.2 2.25204 -2.80526; 346 4.2 1.629 -1.808

29. 347 4.2 1.20362 -1.12484; 348 4.2 0.579625 -0.127121; 349 7 2.25204 -2.80526

30. 350 7 0.579625 -0.127121; 351 7 1.629 -1.808; 352 7 1.20362 -1.12484

31. 357 0 0.791959 -0.466111; 358 2.8 0.791959 -0.466111

32. 359 5.6 0.791959 -0.466111; 360 8.4 0.791959 -0.466111

33. MEMBER INCIDENCES

34. 3 357 113; 9 358 114; 16 260 183; 17 261 184; 20 119 357; 21 120 358

35. 151 324 336; 152 325 337; 155 324 341; 156 328 324; 160 113 260; 161 114 261

36. 164 117 113; 173 123 119; 267 183 199; 268 184 198; 284 199 357; 285 198 358

37. 286 198 188; 287 199 187; 362 183 324; 363 184 325; 368 260 342; 370 113 343

38. 371 119 344; 376 359 274; 377 282 276; 378 275 359; 381 326 338; 382 325 345

39. 383 274 282; 387 276 279; 391 279 359; 392 279 277; 394 276 326; 399 261 346

40. 401 114 347; 402 120 348; 407 360 295; 408 303 297; 409 296 360; 412 327 339

41. 413 326 349; 414 295 303; 416 275 350; 418 297 300; 422 300 360; 423 300 298

42. 425 297 327; 430 282 351; 432 274 352; 438 327 335; 439 295 313; 440 296 314

43. 441 303 315; 446 320 119; 447 321 120; 448 322 275; 449 323 296; 461 338 318

44. 462 339 319; 463 340 260; 464 341 325; 465 342 261; 466 343 114; 467 344 120

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 13 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

45. 468 345 326; 469 346 282; 470 347 274; 471 348 275; 472 349 327; 473 350 296

46. 474 351 303; 475 352 295; 476 342 341; 477 346 345; 478 351 349; 479 350 352

47. 480 348 347; 481 344 343

48. ***** DEFINE MATERIAL SPECIFICATIONS*****************************

49. DEFINE MATERIAL START

50. ISOTROPIC STEEL

51. E 2.05E+008

52. POISSON 0.3

53. DENSITY 76.5

54. ALPHA 1.2E-005

55. DAMP 0.03

56. TYPE STEEL

57. STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2

58. END DEFINE MATERIAL

59. MEMBER PROPERTY COLDFORMED INDIAN

60. 267 268 286 287 387 392 418 423 TABLE ST 150CS50X20X5

61. 155 156 164 173 368 370 371 382 399 401 402 413 416 430 432 438 TO 441 463 -

62. 464 TO 475 TABLE ST 70CS40X3.15

63. 3 9 16 17 20 21 151 152 160 161 362 363 376 TO 378 381 383 394 407 TO 409 -

64. 412 414 425 446 TO 449 461 462 TABLE ST 100CS50X3.15

65. MEMBER PROPERTY COLDFORMED INDIAN

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 14 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

66. 284 285 391 422 TABLE ST 50LU50X3.15

67. 476 TO 481 TABLE ST 30LU30X3.15

68. CONSTANTS

69. BETA 90 MEMB 267 268 286 287 387 392 418 423

70. BETA 20 MEMB 155 156 164 173 368 370 371 382 399 401 402 413 416 430 432 438 -

71. 439 TO 441 463 TO 475

72. BETA 45 MEMB 284 285 391 422

73. MATERIAL STEEL ALL

74. SUPPORTS

75. 187 188 277 298 FIXED

76. DEFINE 1893 LOAD

77. ZONE 0.36 RF 5 I 1 SS 2 ST 1 DM 0.05

78. SELFWEIGHT 1

79. DEFINE WIND LOAD

80. TYPE 1 WIND 1

81. INT 0.714 HEIG 2.252

82. LOAD 1 LOADTYPE SEISMIC TITLE SEISMIC +X DIRECTION

83. 1893 LOAD X 1

84. LOAD 2 LOADTYPE SEISMIC TITLE SEISMIC +Z DIRECTION

85. 1893 LOAD Z 1

86. LOAD 3 LOADTYPE NONE TITLE DEAD LOAD

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 15 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

87. SELFWEIGHT Y -1

88. MEMBER LOAD

89. 155 156 164 173 368 370 371 382 399 401 402 413 416 430 432 438 TO 441 463 -

90. 464 TO 475 UNI GY -0.104

91. *********************************************************************

92. LOAD 4 LOADTYPE NONE TITLE WIND UPLIFT

93. MEMBER LOAD

94. 155 156 164 173 368 370 371 382 399 401 402 413 416 430 432 438 TO 441 463 -

95. 464 TO 475 UNI GY 1.21

96. LOAD 6 LOADTYPE NONE TITLE WIND SIDEWAYS X+

97. MEMBER LOAD

98. 267 268 286 287 387 392 418 423 UNI GX 0.1476

99. 3 9 16 17 20 21 151 152 160 161 362 363 376 TO 378 381 383 394 407 TO 409 -

100. 412 414 425 446 TO 449 461 462 UNI GX 0.0984

101. LOAD 7 LOADTYPE NONE TITLE WIND SIDEWAYS Z

102. MEMBER LOAD

103. 155 156 164 173 368 370 371 382 399 401 402 413 416 430 432 438 TO 441 463 -

104. 464 TO 475 UNI GZ 0.0689

105. 267 268 286 287 387 392 418 423 UNI GZ 0.0492

106. LOAD COMB 8 1.5*DL

107. 3 1.5

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 16 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

108. LOAD COMB 9 1.5*(DL+WLUP)

109. 3 1.5 4 1.5

110. LOAD COMB 11 1.5*(DL+SIDEWAYS+X)

111. 3 1.5 6 1.5

112. LOAD COMB 12 1.5*(DL+SIDEWAYS+Z)

113. 3 1.5 7 1.5

114. LOAD COMB 13 1.5*(DL+SIDEWAYS-X)

115. 3 1.5 6 -1.5

116. LOAD COMB 14 1.5*(DL+SIDEWAYS-Z)

117. 3 1.5 7 -1.5

118. LOAD COMB 15 1.5*(DL+WIND UPLIFT+SIDEWAYS+X)

119. 3 1.5 4 1.5 6 1.5

120. LOAD COMB 16 1.5*(DL+WIND UPLIFT+SIDEWAYS+Z)

121. 3 1.5 4 1.5 7 1.5

122. LOAD COMB 17 1.5*(DL+WIND UPLIFT+SIDEWAYS-X)

123. 3 1.5 4 1.5 6 -1.5

124. LOAD COMB 18 1.5*(DL+WIND UPLIFT+SIDEWAYS-Z)

125. 3 1.5 4 1.5 7 -1.5

126. LOAD COMB 23 1.2*DL+1.2*WIND UPLIFT +WL+X

127. 3 1.2 4 1.2 6 1.2

128. LOAD COMB 24 1.2*DL+1.2*WIND UPLIFT -WL+X

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 17 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

129. 3 1.2 4 1.2 6 -1.2

130. LOAD COMB 25 1.2*DL+1.2*WIND UPLIFT +WL+Z

131. 3 1.2 7 1.2

132. LOAD COMB 26 1.2*DL+1.2*WIND UPLIFT -WL+Z

133. 3 1.2 7 -1.2

134. LOAD COMB 27 1.2*DL+1.2*EQ+X

135. 3 1.2 1 1.2

136. LOAD COMB 28 1.2*DL+1.2*EQ+Z

137. 3 1.2 2 1.2

138. LOAD COMB 29 1.2*DL+1.2*WIND UPLIFT +WL+Z

139. 3 1.2 7 1.2

140. LOAD COMB 30 1.2*DL+1.2*WIND UPLIFT -WL+Z

141. 3 1.2 7 -1.2

142. LOAD COMB 52 1.5*(DL+EQ(+X)

143. 3 1.5 1 1.5

144. LOAD COMB 53 1.5*(DL+EQZ)

145. 3 1.5 2 1.5

146. LOAD COMB 54 DL*(0.9)+1.5*EQX

147. 3 0.9 1 1.5

148. LOAD COMB 55 DL*(0.9)+1.5*EQZ

149. 2 1.5 3 0.9

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 18 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

150. LOAD COMB 56 DL*(0.9)-1.5*EQX

151. 3 0.9 1 -1.5

152. LOAD COMB 57 DL*(0.9)-1.5*EQZ

153. 2 1.5 3 -0.9

154. PERFORM ANALYSIS

155. **** INPUT PARAMETER FOR DESIGN OF STRUCTURE


***************************

156. PARAMETER 1

157. CODE IS801

158. RATIO 1 ALL

159. FYLD 350000 ALL

160. CHECK CODE ALL

STAAD OUTPUT

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 3 SECTION: 100CS50X3.15 LEN: 776.78 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.350 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|
Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 19 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 9 SECTION: 100CS50X3.15 LEN: 776.78 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.459 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 16 SECTION: 100CS50X3.15 LEN: 158.95 GOV.LOC: 158.95 |

| STATUS: PASS RATIO = 0.264 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 17 SECTION: 100CS50X3.15 LEN: 159.19 GOV.LOC: 159.19 |

| STATUS: PASS RATIO = 0.358 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 20 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 20 SECTION: 100CS50X3.15 LEN: 400.00 GOV.LOC: 400.00 |

| STATUS: PASS RATIO = 0.300 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 7

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 21 SECTION: 100CS50X3.15 LEN: 400.00 GOV.LOC: 400.00 |

| STATUS: PASS RATIO = 0.394 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 151 SECTION: 100CS50X3.15 LEN: 30.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 21 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 152 SECTION: 100CS50X3.15 LEN: 30.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 155 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.398 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 156 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 900.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 22 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 160 SECTION: 100CS50X3.15 LEN: 805.02 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.204 GOV.MODE: Bend + Compress GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 8

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 161 SECTION: 100CS50X3.15 LEN: 804.77 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.261 GOV.MODE: Bend + Compress GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 164 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 900.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 23 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 173 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 900.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 267 SECTION: 150CS50X20X5 LEN: 1258.70 GOV.LOC: 1258.70 |

| STATUS: PASS RATIO = 0.811 GOV.MODE: Bending Z GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 268 SECTION: 150CS50X20X5 LEN: 1258.70 GOV.LOC: 1258.70 |

| STATUS: PASS RATIO = 0.986 GOV.MODE: Bending Z GOV.LOAD: 18 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 24 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 284 SECTION: 50LU50X3.15 LEN: 1515.06 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.160 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 9

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 285 SECTION: 50LU50X3.15 LEN: 1515.06 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.193 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 25 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| MEMBER# 286 SECTION: 150CS50X20X5 LEN: 149.30 GOV.LOC: 149.30 |

| STATUS: PASS RATIO = 0.890 GOV.MODE: Bend Z + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 287 SECTION: 150CS50X20X5 LEN: 149.30 GOV.LOC: 149.30 |

| STATUS: PASS RATIO = 0.738 GOV.MODE: Bend Z + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 362 SECTION: 100CS50X3.15 LEN: 1016.69 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.724 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 26 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| MEMBER# 363 SECTION: 100CS50X3.15 LEN: 1016.69 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.958 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 368 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.432 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 10

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 370 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.433 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 27 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 371 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.395 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 376 SECTION: 100CS50X3.15 LEN: 776.78 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.459 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 377 SECTION: 100CS50X3.15 LEN: 159.19 GOV.LOC: 159.19 |

| STATUS: PASS RATIO = 0.358 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 28 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 378 SECTION: 100CS50X3.15 LEN: 400.00 GOV.LOC: 400.00 |

| STATUS: PASS RATIO = 0.394 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 381 SECTION: 100CS50X3.15 LEN: 30.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 11

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 382 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.582 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 29 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 383 SECTION: 100CS50X3.15 LEN: 804.77 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.262 GOV.MODE: Bend + Compress GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 387 SECTION: 150CS50X20X5 LEN: 1258.70 GOV.LOC: 1258.70 |

| STATUS: PASS RATIO = 0.987 GOV.MODE: Bending Z GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 391 SECTION: 50LU50X3.15 LEN: 1515.06 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.193 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 30 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 392 SECTION: 150CS50X20X5 LEN: 149.30 GOV.LOC: 149.30 |

| STATUS: PASS RATIO = 0.890 GOV.MODE: Bend Z + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 394 SECTION: 100CS50X3.15 LEN: 1016.69 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.958 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 12

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 399 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.586 GOV.MODE: Bending Z GOV.LOAD: 16 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 31 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 401 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.583 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 402 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.574 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 407 SECTION: 100CS50X3.15 LEN: 776.78 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.351 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 32 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 408 SECTION: 100CS50X3.15 LEN: 159.19 GOV.LOC: 159.19 |

| STATUS: PASS RATIO = 0.264 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 409 SECTION: 100CS50X3.15 LEN: 400.00 GOV.LOC: 400.00 |

| STATUS: PASS RATIO = 0.300 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 13

| UNITS : MM, KN, KNM, MPA |

| |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 33 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| MEMBER# 412 SECTION: 100CS50X3.15 LEN: 30.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 413 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.581 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 414 SECTION: 100CS50X3.15 LEN: 804.77 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.204 GOV.MODE: Bend + Compress GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 34 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| MEMBER# 416 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.574 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 418 SECTION: 150CS50X20X5 LEN: 1258.70 GOV.LOC: 1258.70 |

| STATUS: PASS RATIO = 0.812 GOV.MODE: Bending Z GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 422 SECTION: 50LU50X3.15 LEN: 1515.06 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.160 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 14

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 35 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 423 SECTION: 150CS50X20X5 LEN: 149.30 GOV.LOC: 149.30 |

| STATUS: PASS RATIO = 0.739 GOV.MODE: Bend Z + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 425 SECTION: 100CS50X3.15 LEN: 1016.69 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.723 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 430 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.586 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 36 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 432 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.582 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 438 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 439 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 37 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

STAAD SPACE -- PAGE NO. 15

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 440 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 441 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 446 SECTION: 100CS50X3.15 LEN: 31.00 GOV.LOC: 31.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 38 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 447 SECTION: 100CS50X3.15 LEN: 31.00 GOV.LOC: 31.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 448 SECTION: 100CS50X3.15 LEN: 31.00 GOV.LOC: 31.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 449 SECTION: 100CS50X3.15 LEN: 31.00 GOV.LOC: 31.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 39 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 16

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 461 SECTION: 100CS50X3.15 LEN: 14.01 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 462 SECTION: 100CS50X3.15 LEN: 14.01 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 463 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 900.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 40 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 464 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.581 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 465 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.587 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 466 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.582 GOV.MODE: Bending Z GOV.LOAD: 16 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 41 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 17

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 467 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.574 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 468 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.582 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 42 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| MEMBER# 469 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.587 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 470 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.583 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 471 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.575 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 43 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| MEMBER# 472 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.399 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 18

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 473 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.400 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 474 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.436 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 44 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 475 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.439 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 476 SECTION: 30LU30X3.15 LEN: 1175.76 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.045 GOV.MODE: Bend Y + Shear GOV.LOAD: 17 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 477 SECTION: 30LU30X3.15 LEN: 1175.89 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.028 GOV.MODE: Bend Y + Shear GOV.LOAD: 15 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 45 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 478 SECTION: 30LU30X3.15 LEN: 1175.89 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.048 GOV.MODE: Bend Y + Shear GOV.LOAD: 15 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 19

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 479 SECTION: 30LU30X3.15 LEN: 1176.78 GOV.LOC: 1176.78 |

| STATUS: PASS RATIO = 0.104 GOV.MODE: Bend Y + Shear GOV.LOAD: 15 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 480 SECTION: 30LU30X3.15 LEN: 1176.78 GOV.LOC: 1176.78 |

| STATUS: PASS RATIO = 0.083 GOV.MODE: Bend Y + Shear GOV.LOAD: 15 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 46 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 481 SECTION: 30LU30X3.15 LEN: 1176.78 GOV.LOC: 1176.78 |

| STATUS: PASS RATIO = 0.096 GOV.MODE: Bend Y + Shear GOV.LOAD: 17 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 3 SECTION: 100CS50X3.15 LEN: 776.78 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.350 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 9 SECTION: 100CS50X3.15 LEN: 776.78 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.459 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 47 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 16 SECTION: 100CS50X3.15 LEN: 158.95 GOV.LOC: 158.95 |

| STATUS: PASS RATIO = 0.264 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 17 SECTION: 100CS50X3.15 LEN: 159.19 GOV.LOC: 159.19 |

| STATUS: PASS RATIO = 0.358 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 20 SECTION: 100CS50X3.15 LEN: 400.00 GOV.LOC: 400.00 |

| STATUS: PASS RATIO = 0.300 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 48 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 23

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 21 SECTION: 100CS50X3.15 LEN: 400.00 GOV.LOC: 400.00 |

| STATUS: PASS RATIO = 0.394 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 151 SECTION: 100CS50X3.15 LEN: 30.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 152 SECTION: 100CS50X3.15 LEN: 30.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 49 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 155 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.398 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 156 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 900.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 160 SECTION: 100CS50X3.15 LEN: 805.02 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.204 GOV.MODE: Bend + Compress GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 50 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 24

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 161 SECTION: 100CS50X3.15 LEN: 804.77 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.261 GOV.MODE: Bend + Compress GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 164 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 900.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 173 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 900.00 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 51 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 267 SECTION: 150CS50X20X5 LEN: 1258.70 GOV.LOC: 1258.70 |

| STATUS: PASS RATIO = 0.811 GOV.MODE: Bending Z GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 268 SECTION: 150CS50X20X5 LEN: 1258.70 GOV.LOC: 1258.70 |

| STATUS: PASS RATIO = 0.986 GOV.MODE: Bending Z GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 284 SECTION: 50LU50X3.15 LEN: 1515.06 GOV.LOC: 0.00 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 52 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| STATUS: PASS RATIO = 0.160 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 25

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 285 SECTION: 50LU50X3.15 LEN: 1515.06 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.193 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 286 SECTION: 150CS50X20X5 LEN: 149.30 GOV.LOC: 149.30 |

| STATUS: PASS RATIO = 0.890 GOV.MODE: Bend Z + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 53 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| |

| MEMBER# 287 SECTION: 150CS50X20X5 LEN: 149.30 GOV.LOC: 149.30 |

| STATUS: PASS RATIO = 0.738 GOV.MODE: Bend Z + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 362 SECTION: 100CS50X3.15 LEN: 1016.69 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.724 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 363 SECTION: 100CS50X3.15 LEN: 1016.69 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.958 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 54 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| |

| MEMBER# 368 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.432 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 26

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 370 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.433 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 371 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.395 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 55 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 376 SECTION: 100CS50X3.15 LEN: 776.78 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.459 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 377 SECTION: 100CS50X3.15 LEN: 159.19 GOV.LOC: 159.19 |

| STATUS: PASS RATIO = 0.358 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 378 SECTION: 100CS50X3.15 LEN: 400.00 GOV.LOC: 400.00 |

| STATUS: PASS RATIO = 0.394 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 56 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 381 SECTION: 100CS50X3.15 LEN: 30.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 27

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 382 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.582 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 383 SECTION: 100CS50X3.15 LEN: 804.77 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.262 GOV.MODE: Bend + Compress GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 57 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 387 SECTION: 150CS50X20X5 LEN: 1258.70 GOV.LOC: 1258.70 |

| STATUS: PASS RATIO = 0.987 GOV.MODE: Bending Z GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 391 SECTION: 50LU50X3.15 LEN: 1515.06 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.193 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 392 SECTION: 150CS50X20X5 LEN: 149.30 GOV.LOC: 149.30 |

| STATUS: PASS RATIO = 0.890 GOV.MODE: Bend Z + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 58 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 394 SECTION: 100CS50X3.15 LEN: 1016.69 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.958 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 28

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 399 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.586 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 401 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 59 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| STATUS: PASS RATIO = 0.583 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 402 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.574 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 407 SECTION: 100CS50X3.15 LEN: 776.78 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.351 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 408 SECTION: 100CS50X3.15 LEN: 159.19 GOV.LOC: 159.19 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 60 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| STATUS: PASS RATIO = 0.264 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 409 SECTION: 100CS50X3.15 LEN: 400.00 GOV.LOC: 400.00 |

| STATUS: PASS RATIO = 0.300 GOV.MODE: Bend + Compress GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 29

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 412 SECTION: 100CS50X3.15 LEN: 30.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 61 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| |

| MEMBER# 413 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.581 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 414 SECTION: 100CS50X3.15 LEN: 804.77 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.204 GOV.MODE: Bend + Compress GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 416 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.574 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 62 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| |

| MEMBER# 418 SECTION: 150CS50X20X5 LEN: 1258.70 GOV.LOC: 1258.70 |

| STATUS: PASS RATIO = 0.812 GOV.MODE: Bending Z GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 422 SECTION: 50LU50X3.15 LEN: 1515.06 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.160 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 30

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 423 SECTION: 150CS50X20X5 LEN: 149.30 GOV.LOC: 149.30 |

| STATUS: PASS RATIO = 0.739 GOV.MODE: Bend Z + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 63 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 425 SECTION: 100CS50X3.15 LEN: 1016.69 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.723 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 430 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.586 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 432 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.582 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 64 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 438 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 439 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 31

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 440 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 65 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 441 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 446 SECTION: 100CS50X3.15 LEN: 31.00 GOV.LOC: 31.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 447 SECTION: 100CS50X3.15 LEN: 31.00 GOV.LOC: 31.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 66 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 448 SECTION: 100CS50X3.15 LEN: 31.00 GOV.LOC: 31.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 449 SECTION: 100CS50X3.15 LEN: 31.00 GOV.LOC: 31.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 32

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 461 SECTION: 100CS50X3.15 LEN: 14.01 GOV.LOC: 0.00 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 67 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 462 SECTION: 100CS50X3.15 LEN: 14.01 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.000 GOV.MODE: Bend Y + Shear GOV.LOAD: 11 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 463 SECTION: 70CS40X3.15 LEN: 900.00 GOV.LOC: 900.00 |

| STATUS: PASS RATIO = 0.287 GOV.MODE: Bend Z + Shear GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 464 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 68 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| STATUS: PASS RATIO = 0.581 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 465 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.587 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 466 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.582 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 33

| UNITS : MM, KN, KNM, MPA |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 69 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| |

| MEMBER# 467 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.574 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 468 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.582 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 469 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.587 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 70 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| |

| MEMBER# 470 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.583 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 471 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.575 GOV.MODE: Bending Z GOV.LOAD: 16 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 472 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.399 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 34

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 71 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 473 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.400 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 474 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.436 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 475 SECTION: 70CS40X3.15 LEN: 1400.00 GOV.LOC: 1400.00 |

| STATUS: PASS RATIO = 0.439 GOV.MODE: Bend Y + Shear GOV.LOAD: 18 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 72 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 476 SECTION: 30LU30X3.15 LEN: 1175.76 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.045 GOV.MODE: Bend Y + Shear GOV.LOAD: 17 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 477 SECTION: 30LU30X3.15 LEN: 1175.89 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.028 GOV.MODE: Bend Y + Shear GOV.LOAD: 15 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 478 SECTION: 30LU30X3.15 LEN: 1175.89 GOV.LOC: 0.00 |

| STATUS: PASS RATIO = 0.048 GOV.MODE: Bend Y + Shear GOV.LOAD: 15 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 73 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

|-----------------------------------------------------------------------------|

STAAD SPACE -- PAGE NO. 35

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 479 SECTION: 30LU30X3.15 LEN: 1176.78 GOV.LOC: 1176.78 |

| STATUS: PASS RATIO = 0.104 GOV.MODE: Bend Y + Shear GOV.LOAD: 15 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 480 SECTION: 30LU30X3.15 LEN: 1176.78 GOV.LOC: 1176.78 |

| STATUS: PASS RATIO = 0.083 GOV.MODE: Bend Y + Shear GOV.LOAD: 15 |

|-----------------------------------------------------------------------------|

|-----------------------------------------------------------------------------|

| UNITS : MM, KN, KNM, MPA |

| |

| MEMBER# 481 SECTION: 30LU30X3.15 LEN: 1176.78 GOV.LOC: 1176.78 |

| STATUS: PASS RATIO = 0.096 GOV.MODE: Bend Y + Shear GOV.LOAD: 17 |

|-----------------------------------------------------------------------------|

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 74 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 75 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 76 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 77 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 78 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 79 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 80 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 81 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 82 of 83
1 MW AC GRID TIED SOLAR PANEL , MES
RAYANG ARUNACHAL PRADESH

Project: Rev

1 MW AC GRID TIED SOLAR PANEL , Doc. No: RT_001-2018-MES-CE-02_MMS 1


MES, ARUNCHAL PRADESH
Date: 24/06/2018 Page 83 of 83

You might also like