Bulletin 128

Rev F July 2015


Supersedes Rev E Jan 2013
Maintenance Record for Lewis® Pumps Sizes 2-1/2-6 MS-MT
Tag #: Weir Minerals Lewis Pumps
Serial #: 8625 Grant Rd
Type: St. Louis, MO 63123
Telephone: 314-843-4437
sales.lewis@weirminerals.com
Allowable Running Clearances
Item Max Allowed Date Date Date
Clearance Changed Changed Changed
Head Plate Journal and Casing
0.04” (1.0 mm)
Ring
Impeller Ring and Casing Ring 0.04” (1.0 mm)
Head Plate Journal and Head
0.035” (0.90mm)
Plate Bearing
IF TYPE MS PUMP:
Intermediate Journal and
0.045” (1.15 mm)
Intermediate Bearing

NOTE: This Maintenance Record is available in editable format. Contact


sales.lewis@weirminerals.com.
1. Check fit between mating parts. This is very important.
2. Maximum allowable clearance (loosest fit) between respective shoulder and counterbore that serves to center
one piece with another is shown in accompanying table.
a. All clearances are measured on diameter.
b. “Negative” clearance indicates force or press fit.
3. Measure parts at two or three locations equally spaced on circumference.
4. If average fit determined from measurements in step 3 is larger than corresponding fit in table, replace one or
both parts involved.

Servicing 2-1/2, 3, 4, 5, & 6 MS - MT • 45