GENERAL NOTES

1. ALL ELECTRICAL WORKS SHALL COMPLY IN


ACCORDANCE WITH THESE PLANS AND SERVICE
SPECIFICATIONS. THE APPLICABLE PROVISIONS OF POWER SERVICE ENTRANCE ENTRANCE
230V, 1∅, 2W, 60HZ
M
THE LATEST EDITION OF THE PHILIPPINE 1/0,2W,230V, 60HZ
ELECTRICAL CODES (PEC). THE RULES AND
REGULATION OF THE LOCAL AUTHORITY AND THE U-BENT RSB
2-38MM² THHN COPER WIRE
REQUIREMENTS OF THE LOCAL POWER COMPANY. IN 32 MM ∅ PVC CONDUIT

ALL ELECTRICAL WORKS SHALL BE UNDER THE


IMMEDIATE SUPERVISION OF A DULY REGISTERED
ELECTRICAL ENGINEER.
2. THE ELECTRICAL SERVICE POWER IS 1-PHASE,
2-WIRE, 230 V AC, 60HZ 125 AMP MAIN
3. WIRING METHOD SHALL BE AS FOLLOWS:
30 AMP 30 AMP

A. FEEDERS AND RISERS CABLE "TV" 1-ACU 2-ACU


30 AMP 30 AMP
- RIGID METALLIC CONDUIT SERVICE ENTRANCE
B. LIGHTING, 3-ACU 4-ACU
30 AMP 20 AMP
POWER RECEPTACLE BRANCH CKT.,
KW-HR. METER
& AUXILIARY - 1-CO 2-CO
20 AMP 20 AMP
POLYVINYL CHLORIDE CONDUIT SCH. 40
3-CO 4-CO
20 AMP 20 AMP
4. ALL WIRES SHALL BE COPPER AND
THERMOPLASTIC INSULATED TYPE UNLESS 5-CO 6-CO
20 AMP 15 AMP
OTHERWISE INDICATED IN THE PLAN. THE MINIMUM
SIZE OF WIRE FOR POWER AND LIGHTING CIRCUIT 7-CO 1-LO
15 AMP 15 AMP
HOMERUN SHALL BE 3.5MM² AND INSULATED FOR
600 VOLTS, SMALLEST RACEWAY SHALL BE 2-LO 3-LO
15 AMP 15 AMP
15MMØ TRADE/NOMINAL SIZE.
4-LO 5-LO
5. ALL OUTLET BOXES SHALL BE GALVANIZED 15 AMP 15 AMP
GAUGE NO. 16 DEEP TYPE WITH FACTORY
6-LO 7-LO
KNOCKOUTS. 15 AMP 15 AMP
6. ALL MATERIALS TO BE USED SHALL BE 8-LO 9-LO
BRAND NEW AND APPROVED TYPE FOR THE 15 AMP 15 AMP

PARTICULAR LOCATION AND PURPOSE. 10-LO 11-LO


7. GROUNDING SYSTEM SHALL BE PROVIDED 20 AMP 20AMP

TO ALL LIGHTING AND POWER CIRCUIT AS PER SPARE SPARE


PHILIPPINE ELECTRICAL CODE REQUIREMENTS.
8. MOUNTING HEIGHT OF WIRING DEVICES
SHALL BE AS FOLLOWS:
14.0mm THW GROUND WIRE
A. LIGHT SWITCH - 1.20M ABOVE
FINISHED FLOOR
B. CONVENIENCE OUTLET - 0.30M ABOVE BOTHWAYS
FINISH FLOOR 1000mm (VERIFY)

C. SAFETY SWITCH - 1.80M ABOVE


FINISH FLOOR
1 SERVICE ENTRANCE POST 2 RISER DIAGRAM
SCALE NTS 4 E SCALE NTS
4 E

CONTRACTOR: ENGINEER: PROJECT TITLE: THIS DRAWINGS,AS AN INSTRUMENTS OF


REPUBLIC ACT REVISIONS: SHEETS:
SERVICE, ARE THE INTELLECTUAL PROPERTY AND
DOCUMENTS OF TEKNIKA BUILDERS WHETHER
THE OBJECT FOR WHICH THEY ARE MADE IS 9266
2- STOREY RESIDENCE EXECUTED OR NOT. IT SHALL BE UNLAWFUL FOR
ANY PERSON TO DUPLICATE OR COPY OF SAID
DESIGNED BY:
04
DOCUMENTS FOR USE IN REPETITION OF AND FOR
TEKNIKA BUILDERS LOC.: SINSAYON, SANTIAGO CITY, ISABELA OTHER PROJECTS OR BUILDING, WHETHER
EXECUTED PARTLY OR IN WHOLE, WITHOUT
TEKNIKA BUILDERS
CONTRACTOR PROFESSIONAL ELECTRICAL ENGINEER PROJECT OWNER: WRITTEN CONSENT OF THE ARCHITECT OR APPROVED BY: SHEET CONTENTS:
AUTHOR OF THE SAID DOCUMENT.
ALL MEASUREMENTS ARE TO BE VERIFIED
TEKNIKA BUILDERS
PCAB CATEGORY:
CATEGORY- D
EXP.:
06/30/19
PRC NO.: EXP.:
MR. EDILBERTO HILARIO CRABAJAL, JR
ON SITE. ALL DISCREPANCIES ARE TO BE
IMMEDIATELY REPORTED TO THE
DRAFTED BY:
M. A. A. E
| | | AS SHOWN
ARCHITECT/AUTHORS/PROJECT MANAGER/SITE
LICENSE NO.: ISS. ON.,AT.: PTR NO.: ISS. ON.,AT.: SUPERVISOR. DATE:
DESIGN BUILD INTERIOR RENOVATE 37452 07/01/18, MAKATI CITY ADD.:SINSAYON, SANTIAGO CITY, ISABELA - SECTION - 33 01/25/2019