Download as pdf or txt
Download as pdf or txt
You are on page 1of 116

Type series booklet

2553.523/12--14 KRT
Submersible motor pumps 2” to 30”
for wet well installation

60 Hz
standard range

Stationary installation
Transportable installation
Other versions on request

Applications Bearings
KRT submersible motor pumps are used for pumping all types of grease lubricated ball bearings
sewage and effluent in water treatment and industry, especially
untreated sewage with long fibrous and solid substances, liquids Designation
containing air and gas as well as raw, activated and digested Example
sludge.
KRT K 150-401 / 80 4 UN G -- S
Operating data Pump type
Capacity Q up to 45 000 USgpm (10 000 m3/h) Impeller type
Head H up to 330 ft (100 m) S, F, E, D, K
Motor power P2 up to 1080 HP (800 kW) Hydraulics dimension
Temperature of Motor size
pumped liquid t up to 140 oF (60 oC) Number of poles
Drive Motor version
U, X, W, Z, UN, XN, WN, ZN
Three-phase asynchronous motor
Material version / variant
200 V, 230 V, 380 V, 460 V, 575 V, others optional
G, G1, G2, GH, C1, C2
Material Installation Type
S= Stationary wet--well installation without cooling jacket
Standard version in cast iron
P= Transportable wet--well installation without cooling jacket
Material variants of wear resistant chromium white iron and K= Stationary wet--well installation with cooling jacket
corrosion-resistant duplex stainless steel D= Stationary dry installation, vertical (S1 operation)
H= Stationary dry installation, horizontal (S1 operation)
Shaft sealing
2 mechanical seals being independent of the direction of rotation,
lubricated with non-toxic oil

New:
Motor versions UK, XK for wet and dry installation with energy-saving motors
(Classification: NEMA MG1 “Energy Efficient Motors”).
KRT

KRT Standard Features

1 Major Castings of ASTM A 48 Class 35 B


9
Cast Iron, Duplex Stainless Steel and
Wear resistant Chromium White Iron to
Brinell 1000 available.
6 2 Automatic monitoring of winding
temperature and moisture.

2 3 Enclosed 1, 2 and 3 vane, recessed, or


X open single vane impellers available to
5 allow a hydraulic selection ideally suited
for a particular application.

4 Wear rings to insure continued high


8 efficiencies and long impeller life.

5 Power cables with grommet and washer.


Cable entry further epoxy sealed to insure
no liquid gets inside the motor even if the
7 cables are severed below water level.

6 Over 250 different dry squirrel cage


K induction motors available. All motors
E approved for Class I, Division I, Group C
10 & D locations by FM and CSA.

7 Pump and motor shafts of stainless steel


or Gr 1045 carbon steel protected
and isolated by stainless steel shaft
sleeves.

1 4 3 11 8 Fasteners of ASTM A 276 Type 316 Ti


X stainless steel.

9 Mating surfaces sealed by o-rings of


Elastomer grommet
BUNA-N, Viton or other materials.
Cable sheathing embedded in resin
Individual cores stripped, tinned and 10 Seals of silicon carbide (standard) or
embedded in resin other materials insures the
proper seal selection for the specific
application.

11 Automatic discharge connections with a


positive seal between pump and elbow
insures zero leakage.

2
KRT

Impeller type
KRT K 150-401 / 80 4 UN G -- S
K, D, E, F, S

K F

Closed non-clogging 2 or 3 vane


impeller Vortex impeller

D S

Open single vane impeller Grinder

! !
E Hydraulic systems with D-, F-, E- and S- impellers
are available only as shown in the documented
Single vane impeller QH parameters. K-impellers can be adjusted to the
required duty point.

Installation Type
KRT K 150-401 / 80 4 UN G -- S
S, P, K, D, H

Stationary wet--well
installation
Stationary dry installation
S without cooling jacket
without cooling jacket,
-- with guide cable or vertical
guide rails D For larger dry pit
submersibles with cooling
K with cooling jacket jackets see separate type
series booklet 2553.524/6--14.
-- with guide cable or
guide rails

Transportable Stationary dry installation


P wet--well installation H without cooling jacket,
without cooling jacket horizontal

Guarantee, Test and Quality Assurance


Each pump is subjected to a functional test to KSB standard ZN 56 525 (dry running test).
Pumps are tested in accordance with Hydraulic Institute Standards and capacities guaranteed to H I.
The quality is assured under a tested and certified quality assurance scheme to EN ISO 9001.

3
KRT

KRT 40, 80, 100 20 30 40 50 m3/h 100 200 300 400 500
with K-Impeller 4 5 l/s 10 20 30 40 50 100 200
400
2--pole (3500 rpm) 100
300
4--pole (1750 rpm)
40--250/ 2p 100--400/ 4p
6--pole (1160 rpm) 200
100--401/ 4p
50
11/2”, 3” & 4” 40
Discharge 80--251/ 2p
100 30
K
100--316/ 4p 20
50 40--250/ 4p
40
100--251/ 4p 10
30
H
20 [m]
5
100--251/ 6p 4

0W 382 466--02 10 3
TDH
[ft] 2
5
50 100 200 300 400 500 1000 2000 3000 4000
Q[US.gpm] Flow

KRT 150, 151, 200 50 m3/h 100 200 300 400 500 1000
with K-Impeller 20 30 l/s 40 50 100 200 300 400
400
4--pole (1750 rpm)
200--631/ 8p 100
6--pole (1160 rpm) 300 200--501/ 6p
8--pole (875 rpm) 151--401/ 4p
200 150--400/ 4p
150--401/ 4p 200--631/ 6p
50
6”, 8” Discharge 40
151--401/ 6p
K 100 30
150--400/ 6p
150--401/ 6p 200--330/ 20
4p
50
200--400 / 4p
40 200--330/ 6p 200--401/ 4p
150--315/ 6p
10
30
200--400/ 6p
200--401/ 6p H
20 [m]
200--315/ 6p 5
0W 382 467--03 4
10 200--316/ 6p 3
m
TDH
[ft] 2
5
200 300 400 500 Q[US.gpm] 1000 2000 3000 4000 5000 7000
Flow

4
KRT

KRT 250, 300 200 300 400 500 m3/h 1000 2000 3000
with K-Impeller 40 50 l/s 100 200 300 400 500
400
4--pole (1750 rpm)
100
6--pole (1160 rpm) 300

8--pole (875 rpm) 250--630/ 8p 250--630/ 6p


200
50
300--503/ 6p
10”, 12” Discharge 40

K 100 250--401/ 6p 30

250--400/ 300--500/ 8p 20
4p
50
250--400/ 6p
40
10
30
H
250--400/ 8p 300--400/ 6p [m]
20 300--401/ 6p
5
0W 382 468--02 4
10 300--400/ 8p 3
TDH 300--401/ 8p
[ft] 2
5
500 Q[US.gpm] 1000 2000 3000 4000 5000 10000 14000
Flow

KRT 350, 400, 500, 500 m3/h 1000 2000 3000 4000 5000
600, 700 200 300 400 500 l/s 1000 2000
with K-Impeller 400
100
6--pole (1160 rpm) 300

8--pole (875 rpm) 200 350--630/ 6p


350--710/ 8p consult factory
10--pole (700 rpm) 50
40
12--pole (585 rpm) 350--630/ 8p
100 30
400--630/ 8p
14”, 16”, 20”, 350--420/ 6p 350--636/ 8p 20
24” & 30” Discharge
50
350--501/ 8p
K 40 600--710/ 12p
350--500/ 10p 350--500/ 8p 10
30 700--900/ 12p
400--500/ 8p H
500--630/ 8p [m]
20
5
500--630/ 10p 600--520/ 10p 4
400--500/ 10p
10 350--501/ 10p 3
TDH
[ft] 2
5
0W 382 469--02 2000 3000 4000 5000 10000 20000 30000 40000
Q[US.gpm] Flow

5
KRT

KRT 80, 100, 150, 50 m3/h 100 200 300 400 500 1000
200, 250, 300 20 30 40 50 l/s 100 200 300 400
400
with D-Impeller
100
4--pole (1750 rpm) 300

6--pole (1160 rpm) 200


8--pole (875 rpm) 50
40
100--251/ 4p
3”, 4”, 6”, 8”, 100 30
10” & 12” Discharge
80--315/ 4p 20
D 150--401/ 6p
50
150--400/ 6p
40
100--315/ 4p 10
30 100--316/ 6p
200--400/ 6p
H
150--315/ 6p [m]
20 100--251/ 6p
5
200--315/ 6p 4
250--400/ 6p
10 150--251/ 6p 3
TDH
0W 386 697--02 250--400/ 8p 300--400/ 8p
[ft] 2
5
200 300 400 500 Q[US.gpm] 1000 2000 3000 4000 5000 7000
Flow

KRT 80, 100, 20 30 40 50 m3/h 100 200 300 400 500


150, 200 4 5 l/s 10 20 30 40 50 100 200
with E-Impeller 300

4--pole (1750 rpm) 200


6--pole (1160 rpm) 50
40
3”, 4”, 6” & 100 30
8” Discharge
80--251/ 4p 20
E
50 100--251/ 4p 150--401/ 6p
40
10
30
80--251/ 6p 200--401
/6p H
20 [m]
150--315/ 6p
5
4
10 3
0W 382 462--02 TDH
[ft] 2
5
50 Q[US.gpm] 100 200 300 400 500 Flow 1000 2000 3000 4000

6
KRT

KRT 40, 80, 2 3 45 m3/h 10 20 30 40 50 100 200 300400


100, 150 0.4 l/s 1 2 3 45 10 20 30 40 50 100 200
with F-Impeller 400
2--pole (3500 rpm) 100
300
4--pole (1750 rpm)
200
6--pole (1160 rpm) 40--250/ 2p 100--401/ 4p
50
80--250/ 2p 40
11/2”, 3”, 4” &
6” Discharge 100 100--316/ 4p 30

F
80--250/ 4p 20
40--250/ 4p 100--250/ 4p
50
150--401/ 6p
40
10
30
80--250/ 6p
150--315/ 6p H
20 [m]
5
4
0W 382 463--03 10 3
TDH
[ft] 2
5
5 10 20 30 40 50 100 200 300400 Q[US.gpm] 1000 2000 3000
Flow

7
KRT

KRT 40 2 m3/h 3 4 5 10 20 30 40
with S-Impeller 0.4 0.5 1 l/s 2 3 4 5 10
400
2--pole (3500 rpm) 100
300

1 1/2” Discharge 200 40--250 /2p


50
S
40
100 30

20
50
40
10
30
H
20 [m]
0W 382 460--02
5
4
10 3
TDH
[ft] 2
5
5 Q[US.gpm] 10 20 30 40 50 100 200
Flow

8
KRT

Technical Data
Cast iron (G, G1, G2, GH)
Pump sizes Material variants Impeller Allow. operating
pressure 1)
Impeller channels Free passage Dia. max Dia. min (Installation Type “D”)
qty. [inch] [mm] [mm] [mm] [bar]
S 40–250 G 4 9/ 7 225 175 --
32
F 40–250 1 25 210 150 --
F 80–250 3 76 265 150 6
F 100–250 4 100 265 166 --
F 100–316 G,, G1,, G2,, GH -- 4 100 290 236 --
F 100–401 4 100 390 270 10
F 150–315 4 3/4 120 290 216 --
F 150–401 5 5/16 135 390 270 10
E 80–251 3 76 270 210 6
E 100–251 3 1/8 -- 3 3/4 90 252 184 6
E 150–315 G 1 4 1/2 -- 4 3/4 110 305 232 6
E 150–401 4 1/2 -- 5 1/2 115 407 348 10
E 200–401 4 3/4 -- 5 1/2 120 400 319 10
D 80--315 2 1/2 65 265 234 6
D 100--251 3 76 265 234 6
D 100--315 3 75 222 196 6
D 100--316 3 3/8 85 306 270 --
D 150--251 4 100 254 225 6
D 150–315 4 100 317 280 --
G G1
G, 1
D 150--400 4 100 363 326 --
D 150--401 4 3/ 110 412 370 --
4
D 200–315 4 100 315 280 --
D 200–400 4 100 402 355 --
D 250–400 4 3/4 120 370 320 --
D 300–400 6 150 408 375 --
K 40–250 3 5/ 15 260 150 --
8
K 80–251 1 1/8 33 185 140 --
G G1,
G, G1 GH
K 100–251 2 3 76 250 175 6
K 100–316 3 80 295 235 --
K 100–400 G 3 3 76 408 355 --
K 100–401 2 50 404 310 10
G G1,
G, G1 GH 2
K 150–315 3 76 310 235 6
K 150–400 G 3 3 76 404 300 --
K 150–401 2 3 76 404 310 10
K 151–401 3 1/8 80 408 300 10
3 3/
K 200–315 G,, G1,, GH 2 4 70 295 245 6
K 200–316 2 4 100 305 265 6
K 200--330 3 2 3/4 70 326 266 10
K 200–400 G 3 76 408 300 --
3
K 200--401 G, G1, GH 3 1/8 80 408 300 10
K 200--501 4 1/8 105 502 400 10
G G1
G, 2
K 200--631 4 1/8 105 622 480 10
K 250--400 3 3 3/8 85 380 290 10
G G1,
G, G1 GH
K 250--401 2 4 1/8 105 400 310 10
K 250--630 G, G1 3 3 1/ 90 630 500 10
2
1) Allow. operating pressure = inlet pressure + pressure at Q = 0 (shut off head)

9
KRT

Technical Data
Cast iron (G, G1, G2, GH)
Pump sizes Material variants Impeller Allow. operating
pressure 1)
Impeller channels Free passage Dia. max Dia. min (Installation Type “D”)
qty. [inch] [mm] [mm] [mm] [bar]
K 300–400 3 4 100 408 300 10
G G1,
G, G1 GH
K 300–401 2 5 5/16 135 408 331 10
K 300–500 3 3 1/2 90 504 430 10
K 300–503 5 2 50 480 405 10
K 350–420 4 100 435 355 6
3
K 350–500 4 1/4 110 508 410 6
K 350–501 2 6 5/8 170 509 492 6
K 350–630 3 5 5/16 135 630 500 10
K 350–636 5 3 75 595 510 10
G G1
G,
K 350--710 4 1/4 110 730 580 10
K 400--500 5 1/8 130 508 443 6
K 400--630 5 1/4 132 620 546 6
K 500–630 3 5 1/ 133 582 520 4
4
K 600--520 5 3/4 145 532 457 4
K 600--710 6 1/2 165 736 685 3
K 700--900 7 1/2 190 850 738 3
1) Allow. operating pressure = inlet pressure + pressure at Q = 0 (shut off head)

Technical Data
Other materials (H, C1, C2)
Pump
p sizes Material variants Impeller
Impeller channels Free passage Dia. max Dia. min
qty. [inch] [mm] [mm] [mm]
F 40–250 1 25 210 150
F 80–250 3 76 265 150
F 100–250 4 100 265 200
F 100–316 H,, C1,, C2 -- 4 100 290 236
F 100–401 4 100 390 270
F 150–315 4 3/ 120 290 216
4
F 150–401 5 5/16 135 390 270
K 40–250 3 5/ 15 260 150
8
K 80–251 1 1/ 33 210 140
8
K 100–251 3 76 256 210
K 100–316 3 76 312 254
K 100–401 2 2 50 404 310
K 150–315 3 76 310 235
K 150–401 3 76 404 330
K 151–401 3 3 1/8 80 404 320
H C1,
H, C1 C2
K 200–315 2 3/4 70 295 245
K 200–316 2 4 100 305 265
K 200–330 2 3/4 70 326 287
3
K 200–401 3 1/8 80 404 330
K 250–400 3 3 3/8 85 370 300
K 250–401 2 4 1/8 105 400 310
K 300–400 3 4 100 408 332
K 300–401 2 5 5/16 135 408 367

10
KRT

General remarks for pump selection


D K impellers are trimmed to the duty point. Therefore, when placing an order always state the flow and head data or the impeller
diameter.
D S, F, D and E impellers can only be supplied with the impeller diameter stated in the documentation. Please add the impeller
diameter to the pump designation whenever an order is placed.
D Performance curves are based on clean water with water density at 40 oF (4 oC) and material variant G.
D The power input has to be adjusted to comply with the density of the pumped medium if necessary.
D For pumps in material variants other than cast iron (G), the documented efficiency must to be reduced by 2 points.
D To balance the inevitable tolerances of the characteristic curve of the plant, the pump, the motor etc., we recommend to select a
motor size with sufficient power reserve.
D The absorbed power of the integrated cooling system reduces the available shaft power depending on motor size and speed:

Motor size absorbed power


[Hp] [kW]
80 4..NG -- 110 4..NG 3.5 2.6
60 6..NG -- 100 6..NG 2.4 1.8
50 8..NG -- 75 8..NG 1.6 1.2
130 4..NG -- 175 4..NG 4.6 3.4
120 6..NG -- 165 6..NG 3.4 2.5
90 8..NG -- 130 8..NG 2.0 1.5
4010..NG -- 9010..NG 1.3 1.0

D Motors are designed for VFD operation.


D Service factor for all motors is 1.15

General instructions on the operation of submersible motor pumps in waste water.


D Caution! In waste water, low flow velocities in the discharge pipe will result in clogging and increased wear.
In vertical riser pipes, the flow velocity must not be less than 6.5 ft/s (2 m/s).
D Caution! In waste water, insufficient circumferential speeds of the impeller will lead to clogging of the hydraulic system (frequency
inverter operation).
The circumferential speed, which is measured on the outside diameter of the impeller, must not be less than 49 ft/s (15 m/s).

Materials
Cast Iron Duplex Steel Wear resistant Chromium
ASTM A 48 Class 35 B Cast Stainless Steel White Iron
Laminate Graphite Cast Iron (ASTM A 890 CD 4 MCu or (A 532 II C 15 % CrMo-Hc or a
a technically equivalent material) technically equivalent material)

This graphited cast iron is mostly used The resistance to pitting of this A wear resistant chilled cast iron for
in the pumping of municipal sewage, ferritic-austenitic stainless cast steel abrasive media, such as liquids
sludges and rain- or surface water. makes it particularly suitable to pump containing sand, ashes or scale.
Suitable for neutral, slightly sewage containing substantial Its hardness is approximately 61.5
aggressive media and media unlikely amounts of chlorides and acids or to 68 Rockwell and therefore higher
to cause excessive wear. sea- and brackish water. Its good than hardened chromium steel. The
The pH value of the pumped medium chemical neutrality, even against alloyed cast iron of chromium-
should be ≥6.5, sand content ≤0.5 g/l. sewage containing phosphorus and molybdenum has a significantly
sulphur, has ensured its wide higher resistance to wear than cast
application in the chemical and iron or other cast materials.
process industries. Pumps made
from duplex steel have been used
very successfully to pump brine,
chemical effluents (pH 1--12) foul
water and seepage from waste
disposal sites.

11
KRT

Guide to material and hydraulics selection for individual pumped liquids


The table below is intended as a guide for selecting pump materials and hydraulics and is based on many years of KSB experience.
The data given in the table is intended as a recommendation / guide only. For more detailed information, please consult your nearest
KSB sales office or ask for expert advice from the KSB advisory departments. Take advantage of the extensive KSB laboratory
know-how when selecting pump materials.
Recommended Suggested
Pumped liquid Comments and recommendations
material impeller type
Dirty water
River water K, D, E, F free p
passage
g >solids in pumped
p p liquid,
q possibly
p y pre-screened
p
Storm water
Waste water
-- untreated municipal sewage F, S, D, E, K free passage of min 3” (76 mm) recommended
-- containing gas and air F up to 8 %, consult KSB when pumping highly gaseous liquids
Sludges
-- raw sludge F, D, E, K
can be pumped with a solids content:
-- digested sludge F, D, E, K 13 % (D), 8 % (F), 6 % (E), 5 % (K)
-- activated sludge D, K
Industrial effluent contaminated with ...
-- paint suspension K solvent-free; refer to operator instruction
-- varnish suspension F, E solvent-free; consult KSB for silicone-free version
-- fibrous substances F, S, D
-- filings / chippings K, F G2 or GH variant, special mechanical seal
-- abrasive substances K, F Solids content <5 g/l
Industrial effluent, slightly acid K, F ph-value >6 G, G1 variant and FPM (Viton) O-rings
Waste water, chemically neutral in respect of corrosion
-- ammonia water K
C t
Cast -- ammonia hydroxide 5 % NH4OH K
-- urea 25 % (NH2)2-CO K
-- potassium hydroxide 10 % KOH K
-- calcium hydroxide 5 % Ca(OH)2 K
-- sodium hydroxide 5 % NaOH K
-- sodium carbonate 30 % Na2CO3 K
Waste water, chemically neutral in respect of corrosion, contaminated with ...
-- aliphatic hydrocarbons,
K
e.g. oils, petrol, butane, methane
-- aromatic hydrocarbons,
K
e.g. benzene, styrene
-- chlorinated hydrocarbons, FPM (Viton) O-rings, for high concentrations consult KSB
e.g. trichloroethylene, ethylene chloride, K
chloroform, methylene chloride
Highly abrasive industrial waste water (chemically neutral)

A sinter content of <5 g/l requires GH design


-- sinter water K
A sinter content of >5 g/l requires H design

-- lime-milk with quartz and pigment up to 15 % lime-milk requires GH design


K
suspension >15 % lime-milk requires H design

-- wash water containing solids K, F


material variant depends on liquid analysis
-- waste water containing dust / ash K

Wear resWater-sand mixture K, F up to 5 g/l solids content requires GH variant -- above 5 g/l: H variant

DuplexSea water K, F C2-variant


C1 or G1 (with 250 mm 2-comp. epoxy resin),
StainlesBrackish water K, F
-- depending on salt content
Steel Corrosive industrial effluent K, F C1 or C2, depending on analysis of pumped media

12
KRT

Material options Material comparison


The main parts used in KSB submersible pumps are ASTM equivalent EN
constructed in: A 48 Class 35 B JL 1040
-- cast iron A 48 Class 35 B (JL 1040) A 532 II C 15 % CrMo-Hc JN 3029
-- wear resistant chromium white iron A 890 CD 4 MCu 1.4517
A 532 II C 15 % CrMo-Hc (JN 3029) A 276 Type 420 1.4021
-- duplex stainless steel A 890 CD 4 MCu (1.4517) or A 276 Type 316 1.4401

alternative materials of equal technical value. A 182 F51 1.4462


A 276 Type 316 Ti 1.4571
A 576 Gr. 1045 C 45 + N
galv. steel 1.0038 + Z
NBR NBR
FKM FPM
A 536: 60--40--18 JS 1030
AISI 329 VG 434
Grey cast iron Industrial materials
G = standard version GH = like G, H = hydraulic components C1 = parts in contact with the media of
parts in contact with the media in but impeller and of wear resistant duplex stainless steel with
cast iron intermediate casing in chromium white iron, elastomer bellows-type mechani-
G1 = like G, wear resistant mechanical seal with cal seal and 316 SS bolts
but duplex stainless steel chromium white iron covered spring C2 = parts in contact with the media of
impeller duplex stainless steel,
G2 = like G, mechanical seal with covered
but wear resistant spring, bolts in A 182 F51 and
chromium white iron impeller Tefzel cable

Part
Part- Material combination
No. Component G G1 G2 GH H C1 C2
Pump unit
101 Pump casing A 48 class 35 B A 532 II C 15 % CrMo-Hc A 890 CD 4 MCu
135 Wear Plate (for D-impeller) A 48 Class 35 B --
502 Casing wear ring (if existing) A 48 Class 35 B AISI 329
Impeller A 48 A 890
230 (D-impeller A 48 Class 35 B, Class 35 CD 4 A 532 II C 15 % CrMo-Hc A 890 CD 4 MCu
with hardened edges) B MCu
Impeller wear ring AISI 329
113/163 Intermediate casing A 48 class 35 B A 532 II C 15 % CrMo-Hc A 890 CD 4 MCu
433.01 Mechanical seal (motor end) Carbon/Si-Carbide
433.02 Mechanical seal (pump end) Si-Carbide/Si-Carbide
A 276 Type 420 / A 276 Type 420 / A 182 F51 /
210 Shaft A 576 Gr. 1045 with shaft protection sleeve A 276 Type 420 A 576 Gr. 1045
(see see table, page 14) (see table, page 15)
330/ Bearing bracket/
A 48 Class 35 B (see p. 14) A 890 CD 4 MCu
350 Bearing housing
811 Motor casing A 48 Class 35 B A 890 CD 4 MCu
A 276 Type
812 Motor housing cover A 48 Class 35 B A 182 F51
316 Ti
410 Elastomers Nitrile rubber (NBR) Viton (FKM)
900 Bolts A 276 Type 316 Ti A 276 S 31803
Installation parts
72-1 Discharge elbow A 48 class 35 B A 532 II C 15 % CrMo-Hc A 890 CD 4 MCu
A 48 class 35 B with
732 Claw A 48 class 35 B A 890 CD 4 MCu
liner of AISI 329
894 Bracket A 276 Type 316 up to 12” discharge; galv. steel for sizes bigger than 12” A 890 CD 4 MCu
572 Clamp A 276 Type 316 up to 12” discharge; A 48 Class 35 B for sizes bigger than 12” A 890 CD 4 MCu
A 276 Type 316
59-24 Guide cable A 276 Type 316
Teflon coated
A 276 Type
892 Foot plate galv. steel A 890 CD 4 MCu
316 Ti
885 Lifting chain /-Rope galv. steel, A 276 Type 316 upon request Polypropylene (PP)

13
KRT

TECHNICAL DATA -- STANDARD PROGRAM / (standard-options)


Material options G, G1, G2, GH
Motor size
2-pole 5 2 ... 17 2 22 2 ... 25 2 37 2 ... 55 2 -- --
4-pole 5 4 ... 16 4 19 4 ... 29 4 35 4 ... 65 4 80 4N 95 4N ... 350 4
6-pole 4 6 ... 12 6 15 6 ... 26 6 32 6 ... 50 6 60 6N 80 6N ... 480 6N
8-pole 10 8, 21 8 -- 26 8, 35 8 50 8N 75 8N ... 400 8N
10-pole -- -- -- -- 40 10N ... 350 10N
12-pole -- -- -- -- 105 12N ... 310 12N
Inlet flange (Opt.: drilled to ANSI B 16.1 Class 125; Attention: not possible for all sizes -- consult factory)
Shaft material A 276 Type 420 A 576 Gr. 1045 A 276 Type 420
shaft protection sleeve -- A 276 Type 420
rolling element with lifetime
lubrication
pump side: rolling element bearings
for impeller type D: with re--lubrication facility
Bearings rolling element bearings sealed for life pump side: rolling element bearings
with re--lubrication facility motor side: rolling element bearings
sealed for life
motor side: rolling element bearings
sealed for life
Motor
Version U standard, non explosion-proof
Version X explosion-proof, to Class I, Division 1, Groups C & D, T3
Version W version for pumped liquids with temperatures up to 140 oF (60 oC), non-explosion-proof, without cooling jacket
Version Z version for pumped liquids with temperatures up to 140 oF (60 oC), explosion-proof, without cooling jacket
Starting method across the line (D.O.L.), soft starter, VFD or star-delta
460 V
Voltage (Opt.: 200 V, 230 V, 460 V (Opt.: 380 V, 575 V)
380 V, 575 V)
Cooling ambient ambient (Opt.: cooling jacket)
Immersion depth max. 100 ft
Neoprene, type see motor catalogue (Opt.: shielded cable)
Power cable
(Opt.: Tefzel = fluoropolymer ETFE modified) --
Length 30 ft (Opt.: up to 150 ft)
Entry sealed over its entire length
Sealing
Elastomers nitrile rubber NBR (Opt. Viton = fluororubber FPM)
Shaft sealing bellows-type mechanical seal (Opt.: mechanical seal with covered spring)
Winding Protection
PTC control circuit; control circuit for
Bi-Metallic Switches; control circuit for automatic start/stop when
Version U, X, W, Z automatic start/stop when reaching
reaching the admissible winding temperature.
the admissible winding temperature.
Monitoring
Bearing temp. -- with PT100 on pump side
Moisture moisture sensor in motor chamber
Mechanical seal
-- Float switch in leakage chamber
-- leakage
Version UN, XN
-- Coolant temperature
with cooling jacket
Vibration sensor -- option
Primer with 11/2 -- 2 mils (35--50 mm) dry film thrickness
Coating Top coat of two component epoxy coating, non-toxic with 6 mils (150 mm) dry film thrickness colour RAL 5002
(Opt.: 12 mils (300 mm) of total dry film thickness)
Max. temperature of pumped media
Version U, X 104 oF (40 oC)
Version W, Z 140 oF (60 oC)
Tests
according to KSB standard
Hydraulic tests
(Opt.: Impeller types S, D, E, F to Hydraulic Institute, Level B, impeller type K to Hydraulic Institute, Level A)
General accep. test according to KSB standard
Installation
stationary with guide
cable
Standard installation depth to 100 ft,
ft increased depth with pre-approval
stationary with guide rail
installation
transportable up to size 300-401 except sizes 200-501, 200-631, 250-630
stationary, dry -- with cooling jacket

14
KRT

TECHNICAL DATA -- STANDARD PROGRAMME / (standard options)


Material options H, C1, C2
Motor size
2-pole 5 2 ... 17 2 22 2 ... 25 2 -- -- --
4-pole 5 4 ... 16 4 19 4 ... 29 4 35 4 ... 65 4 80 4 80 4 ... 175 4
6-pole 4 6 ... 12 6 15 6 ... 26 6 32 6 ... 50 6 60 6 60 6 ... 165 6
8-pole 10 8, 17 8 21 8 26 8 ... 35 8 50 8 75 8 ... 130 8
Inlet flange (Opt.: drilled to ANSI B 16.1 Class 125; Attention: not possible for all sizes -- consult factory)
Shaft material
A 276 Type 420 A 576 Gr. 1045 A 276 Type 420
for material variants H
shaft protection sleeve -- A 276 Type 420
Shaft material
A 182 F51 / A 576 Gr. 1045 A 276 Type 420
for material variants C1, C2
shaft protection sleeve -- A 182 F51
pump side: rolling element bearings
with re--lubrication facility
Bearings rolling element with lifetime lubrication+
motor side: rolling element
with lifetime lubrication
Motor
Version U standard, non-explosion-proof
Version X explosion-proof, to class I, Division 1, Groups C & D, T3
Version W version for pumped liquids with temperatures up to 140 oF (60 oC) (non-explosion-proof)
Version Z version for pumped liquids with temperatures up to 140 oF (60 oC) (explosion-proof)
Starting method across the line (D.O.L.) soft starter, VFD or star-delta
460 V
460 V
Voltage (Opt.: 200 V, 230 V,
(Opt.: 380 V, 575 V)
380 V, 575 V)
Cooling ambient
Immersion depth max. 100 ft
Power cable Neoprene, type see motor catalogue, (Opt.: shilded cable)
-- Special cable (Opt.: TEFZEL = fluoropolymer ETFE modified)
Length 30 ft (Opt.: up to 150 ft)
Entry sealed over its entire length
Sealing
Elastomers nitrile rubber NBR, (Opt.: fluororubber), for C2 always fluororubber FPM
C1: bellows-type mechanical seal (Opt.: mech. seal with covered spring)
Shaft sealing
H, C2: mechanical seal with covered spring
Winding Protection
Version U, X, W, Z Bi-Metallic Switches; control circuit for automatic start/stop when reaching the admissible winding temperature.
Monitoring
Moisture moisture electrode in motor chamber
H: Primer with 11/2 -- 2 mils (35--50 mm) dry film thrickness, top coat of two component epoxy coating, non-toxic
Coating with 6 mils (150 mm) dry film thrickness colour RAL 5002 (Opt.: 12 mils (300 mm) of total dry film thickness)
C1, C2: without painting
Max. temperature of pumped media
Version U, X 104 oF (40 oC)
Mot.version W, Z 140 oF (60 oC)
Tests
according to KSB standard
Hydraulic tests
(Opt.: Impeller types S, F to Hydraulic Institute, Level B, impeller type K to Hydraulic Institute, Level A
General
according to KSB standard
acceptance test
Installation
stationary with guide cable
Standard installation depth to 100 ft,
ft increased depth with pre-approval
transportable

15
KRT

Typical sectional drawing of size from 5.5 hp (4 kW) to 40 hp (30 kW)

Example: KRT E 150-315/20 6 WG Applicable for motor codes: 6 2 to 23 2


5 4 to 29 4
4 6 to 26 6

811

210

330

433.01
410

113 410

433.02

X
X 101 502 230 900
503

option:
impeller wear ring

16
KRT

Typical sectional drawing of size >40 hp (30 kW) up to approx. 80 hp (60 kW)

Example: KRT 150-401/65 4 XG Applicable for motor codes: 23 4 to 65 4


20 6 to 50 6
10 8 to 35 8

811

210

330
412

113

X
X
503

option: 900 502 230 101


impeller wear ring

17
KRT

Typical sectional drawing KRT D of size >6.5 hp (4.8 kW) up to approx. 50 hp (37.3 kW)

Example: Amarex KRT D 300-400 / 21 8 XG Applicable for motor codes: 4 6 to 50 6


10 8 to 26 8

811

210

900

410

330
433.01

900

433.02

113

230

410

101

502

18
KRT

Typical sectional drawing


-- KRT without cooling jacket of size >47 hp (50 kW) up to approx. 640 hp (480 kW)

Example: KRT K 150-401/1304 XN G Applicable for motor codes: 80 4 N to 350 4 N


Type S installation. 60 6 N to 480 6 N
50 8 N to 400 8 N
40 10 N to 350 10 N
105 12 N to 310 12 N

811

210
410

900 433.01

350

433.02

163

230

502
101

19
KRT

Typical sectional drawing


-- KRT with cooling jacket of size >47 hp (50 kW) up to approx. 590 hp (440 kW)

Example: KRT K 150-401/1304 XN G Applicable for motor codes: 80 4 N to 350 4 N


Type K installation. 60 6 N to 480 6 N
50 8 N to 400 8 N
40 10 N to 350 10 N
105 12 N to 310 12 N

811

210

350

900
433.01
433.02

163

410
101

230

502

20
KRT

Shaft Seal
Standard version
Mechanical seal with elastomer bellows (NBR, optional: Viton) for all kinds of waste water.

motor side

pump side

Standard variant
Inboard mechanical seal with covered spring for heavily abrasive products or products containing metal solids.

motor side

standard for H and C2


(optional for G, G1, G2, GH, C1)

pump side

21
KRT

Closed non-clogging impellers 11/2”, 3” & 4”

KRT 40, 80, 100 K--Impeller


with K-Impeller
K
2--pole (3500 rpm)
4--pole (1750 rpm)
6--pole (1160 rpm)

20 30 40 50 m3/h 100 200 300 400 500


4 5 l/s 10 20 30 40 50 100 200
400
100
300

40--250/ 2p 100--400/ 4p
200
100--401/ 4p
50
40
100 80--251/ 2p
30

100--316/ 4p 20
50 40--250/ 4p
40
100--251/ 4p 10
30
H
20 [m]
5
100--251/ 6p 4
10 3
TDH
[ft] 2
5
50 100 200 300 400 500 1000 2000 3000 4000
Q[US.gpm] Flow

0W 382 466--02

22
KRT

KRT K 40-250 3500 rpm 1 1/2 inch


3
K 0 20 40 m /h 60 70

0 5 10 l/s 15 19
360

20 30 100
40

300
46
50
53
53
η [%]
ø210

m
20 30
40
46
TDH 50
53
200
55
55.2
55

20
50
ft 30
40
53
46 ø180
50
53
54.6
100 53
50
ø150

40
0 50 100 150 200 250 300
US.gpm

30
20
hp
ø210
Power Input kW
20
ø180

10

10 ø150

2
0 50 100 150 200 250 300
Flow
US.gpm
K42108/3
Free passage 5/
8” (15 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2


Hp kW Hp kW oF oC

82U
104 40
82X *)
10 75
7.5 10 75
7.5
122W
140 60
122Z *)
122U
15 11 2
11.2 15 11 2
11.2 104 40
122X *)
172W
20 14 9
14.9 20 14 9
14.9 140 60
172Z *)
172U
23 17 2
17.2 22 16 4
16.4 104 40
172X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

23
KRT

KRT K 40-250 1750 rpm 1 1/2 inch


3
K 0 20 40 m /h 60

0 5 10 l/s 15 18
130

120 20 30
40
46
50

100 20 30
53
54
η [%]
40
46
50 53
53
80 53.8 50
20 30
TDH 40 53
46
50 46
53
50 20
60 53.3
53
20 46 40
30 40
ft 46
50
50
40 ø260
52.3 46
m
40 50 ø235
20 30 40 40
46 46
50
51.3 ø210
50 40
46
20 40 ø180
5
ø150

5
0 50 100 150 200 250 290
US.gpm

10

ø260
kW
hp

ø235 5
Power Input

5
ø210

ø180

ø150

0 0
0 50 100 150 200 250 290
Flow
US.gpm
K42109/3
Free passage 5/
8” (15 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

44UK IE3 74UK IE3


-- -- 104 40 -- --
44XK IE3*) 74XK IE3*)
5 37
3.7 104 40
54W 74U
5 37
3.7 140 60 10 75
7.5
54Z *) 74X *)
10 75
7.5
54UK IE3 114W
-- -- 140 60
54XK IE3*) 114Z *)
104 40
54U
75
7.5 56
5.6
54X *) New:
75
7.5 56
5.6
74W
140 60 Motor versions UK, XK for wet and dry installation
74Z *)
*)
with energy-saving motors
FM/CSA = Explosionproof to Class I, Division 1, Groups C & D (Classification: NEMA MG1 “Energy Efficient Motors”).

24
KRT

KRT K 80-251 3500 rpm 3 inch


K 0 50 m#/h 100 150 200 250

0 20 l/s 40 60
230

200 60
Qmin
50
56
60
50
64
150 56
60 η [%] 40
TDH 50
67.1
64
56
65.1
60
100 64 m
64
50
62.5 60
ft 56
60 ø185
20
60 56
59.8 ø175
50 56

56
ø160
ø140

0 0
0 200 400 600 US.gpm 800 1000

0 200 IM.gpm 400 600 800


35
ø185

20
ø175
Power Input
20
ø160
kW
hp ø140

0 0
0 200 400 600 US.gpm 800 1000
Flow K43195--00
Free passage 1 1/8” (33 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

122W 252W
10 75
7.5 10 75
7.5 140 60 25 18 7
18.7 24 17 9
17.9 140 60
122Z *) 252Z *)
122U 222U
15 11 2
11.2 15 11 2
11.2 104 40 30 22 4
22.4 -- --
122X *) 222X *)
104 40
172W 252U
20 14 9
14.9 20 14 9
14.9 140 60 34 25 3
25.3 30 22 4
22.4
172Z *) 252X *)
172U
23 17 2
17.2 22 16 4
16.4 104 40
172X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

25
KRT

KRT K 100-251 1750 rpm 4 inch


K 0 100 m#/h 200 300

0 20 l/s 40 60 80
120

Qmin
100 50 30
56
60
63
66

80
50
56
60
69
71 η [%] m
63
66
50
56 69
72.8 Qmax
TDH 60
63 71 71 20
66 71.4
60 50 ø250
71
56
60 69 69
ft 63
50 ø235
56 64 66
40 60
63 63
61.4 ø220
50
56 60
60 10
58.7 ø205
56 56
20 ø190
ø175

5
0 200 400 600 800 1000 1200 1400
US.gpm
0 200 IM.gpm 400 600 800 1000 1200

30 ø250
20

ø235
Power Input 20 kW
ø220
hp
ø205 10

10 ø190
ø175

0 0
0 200 400 600 800 1000 1200 1400
Flow
US.gpm
Free passage 3” (76 mm) K42595--04

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

54UK IE3 114U


-- -- 104 40
54XK IE3*) 114X *)
104 40 15 11 2
11.2 15 11 2
11.2
54U 164W
75
7.5 56
5.6 140 60
54X *) 164Z *)
75
7.5 56
5.6
74W 164U
140 60 104 40
74Z *) 164X *)
20 14 9
14.9 20 14 9
14.9
74UK IE3 214W
-- -- 140 60
74XK IE3*) 214Z *)
104 40
74U 194U
10 75
7.5 25 18 6
18.6 -- -- 104 40
74X *) 194X *)
10 75
7.5
114W 214U
140 60 30 22 3
22.3 25 18 6
18.6 104 40
114Z *) 214X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

New: Motor versions UK, XK for wet and dry installation with energy-saving motors
(Classification: NEMA MG1 “Energy Efficient Motors”).
26
KRT

KRT K 100-251 1160 rpm 4 inch


3
K 0 50 100 m /h 150 200 220

0 20 l/s 40 60
54

50 15
Qmin
50
56
60
40 63
66
50
50
56
60
69
71
η [%]
63 10
50 66 71.5
TDH 30 56
60 69 71
63
70.1 69
ft 50 66 ø250 m
56 69
60 67.6

20 50
62.7 66 ø235
56
63
60 60.1 5
50 60 60 ø220
56
57.3 ø205
56 56
10 ø190
ø175

2
0 200 400 600 800 1000
US.gpm

10

ø250
kW
hp
ø235 5
Power Input

ø220
5
ø205

ø190
ø175

0 0
0 200 400 600 800 1000
Flow
US.gpm
K42882/1
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

46U 96U
65
6.5 48
4.8 104 40
46X *) 96X *)
104 40 10 75
7.5 10 75
7.5
46UK IE3 126W
65
6.5 48
4.8 -- -- 140 60
46XK IE3*) 126Z *)
66W
60
6.0 45
4.5 140 60
66Z *)
66U
75
7.5 56
5.6 104 40
66X
66UK IE3 New:
75
7.5 56
5.6 -- -- 104 40
66XK IE3*)
96W Motor versions UK, XK for wet and dry installation
75
7.5 56
5.6 140 60 with energy-saving motors
96Z *)
*)
(Classification: NEMA MG1 “Energy Efficient Motors”).
FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

27
KRT

KRT K 100-316 1750 rpm 4 inch


3
K 0 100 200 m /h 300 340

0 20 40 l/s 60 80 95
170

160
Qmin
66
η [%]
140 70
72
74 75
75.2 40
66 ø295
70
120 72
74
75
TDH 76.5
66
70
72 77.1
100 74 ø280 m
66 75
ft 70 75.6
72
75
80 74 ø265
66 74.5
70 74
72
72.3 20
ø250
60 72

ø235

40
0 200 400 600 800 1000 1200 1400 1550
US.gpm

40 ø295 ø280

ø265 kW
hp
Power Input ø250
20
ø235
20

0 0
0 200 400 600 800 1000 1200 1400 1550
Flow
US.gpm
K42594/1
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2


Hp kW Hp kW oF oC

164U
104 40
164X *)
20 14 9
14.9 20 14 9
14.9
214W
140 60
214Z *)
294W
31 23 1
23.1 28 20 9
20.9 140 60
294Z *)
294U
36 26 8
26.8 34 25 4
25.4 104 40
294X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

28
KRT

KRT K 100-400 1750 rpm 4 inch


K 0 100 m#/h 200 300 400

0 20 l/s 40 60 80 100 120


330 100

300
Qmin
55
60
TDH 65

250
70
73
η [%] 80

55 75
60 75.3
65
75 m
70
73 ø408

200 55
60
74.5
60
65
73
70
ft 73 ø385
73.7

150 73

70
40
65
ø355

100
0 200 400 600 800 1000 1200 1400 1600 1800 2000
US.gpm
0 500 IM.gpm 1000 1500
150
ø408
100
hp
ø385
Power Input 100 kW
ø355

50

50

10
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Flow US.gpm
K43198--00
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC

504U 954WN
104 40 121 90 2
90.2 140 60
504X *) 954ZN *)
65 48 5
48.5
654W 954UN
140 60 127 94 7
94.7 104 40
654Z *) 954XN *)
654U 1104WN
83 61 9
61.9 104 40 134 99 9
99.9 140 60
654X *) 1104ZN *)
804WN
100 74 6
74.6 140 60
804ZN *)
804UN
107 79 8
79.8 104 40
804XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

29
KRT

KRT K 100-401 1750 rpm 4 inch


3
K 0 100 200 m /h 300 360

0 20 40 l/s 60 80 100
330 100
Qmin
300 40
50
60

TDH
250 40
65
70 η [%] 80
50 73
60
65
74
70 ø404
200 73
60
40 50 75
60
ft 65 75.7
40 m
50 70 ø370
60
150 65
73
70 73.3 40
73
71.9
100 ø330
70
ø310
20
60
0 200 400 600 800 1000 1200 1400 1600
US.gpm

120
ø404
100
kW
ø370
Power Input hp
50
ø330
50
ø310

0 0
0 200 400 600 800 1000 1200 1400 1600
Flow US.gpm
K42591/1
Free passage 2” (50 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

294U 804WN
36 26 8
26.8 -- -- 104 40 100 74 6
74.6 75 56 140 60
294X *) 804ZN *)
354W 804UN
45 33 6
33.6 37 27 6
27.6 140 60 107 79 8
79.8 90 67 104 40
354X *) 804XN *)
354U 954WN
104 40 121 90 2
90.2 95 71 140 60
354X *) 954ZN *)
50 37 3
37.3 45 33 6
33.6
504W 954UN
140 60 127 94 7
94.7 100 75 104 40
504Z *) 954XN *)
504U 1104WN
104 40 -- -- 115 86 140 60
504X *) 1104ZN *)
65 48 5
48.5 56 41 8
41.8
654W
140 60
654Z *)
654U
83 61 9
61.9 74 55 2
55.2 104 40
654X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
30
KRT

Closed non-clogging impellers 6” & 8”

KRT 150, 151, 200 K--Impeller


with K-Impeller
K
4--pole (1750 rpm)
6--pole (1160 rpm)
8--pole (875 rpm)

50 m3/h 100 200 300 400 500 1000


20 30 l/s 40 50 100 200 300 400
400
200--631/ 8p 100
300 200--501/ 6p
151--401/ 4p
200 150--400/ 4p
150--401/ 4p 200--631/ 6p
50
40
151--401/ 6p
100 30
150--400/ 6p
150--401/ 6p 200--330/ 20
4p
50
200--400 / 4p
40 200--330/ 6p 200--401/ 4p
150--315/ 6p
10
30
200--400/ 6p
200--401/ 6p H
20 [m]
200--315/ 6p 5
4
10 200--316/ 6p 3
m
TDH
[ft] 2
5
200 300 400 500 Q[US.gpm] 1000 2000 3000 4000 5000 7000
Flow
0W 382 467--03

31
KRT

KRT K 150-315 1160 rpm 6 inch


3
K 0 100 200 m /h 300 400 480

0 20 40 60 l/s 80 100 120 135


75

Qmin
20
55
60
60 65
70
55 60
65
70
75
78 η [%]
80
55 60 75 m
65 78 81.4
70
TDH 55 75 80
60 80
40 65 78 80.3
70 80 78
78.9
55 75 78 75
60
65 78
75 70
10
ft 70 77.5
55 75 70 65
60
65 65
74.3 75 70 ø310
70 65
20 70.4 70 ø295
70 70 65 ø280
65 ø265
65
ø250
ø235
5
0 200 400 600 800 1000 1200 1600 1800 2000 2200
US.gpm

20 ø310

kW
ø295
hp
Power Input ø280 10

10 ø265

ø250
ø235

0 0
0 200 400 600 800 1000 1200 1600 1800 2000 2200
Flow
US.gpm
Free passage 3” (76 mm) K42579/1

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

46UK IE3 126U


104 40 15 11 2
11.2 15 11 2
11.2 104 40
46XK IE3 *) 126X *)
65
6.5 48
4.8 -- --
66W 156U
140 60 20 14 9
14.9 -- -- 104 40
66Z *) 156X *)
66UK IE3 196W
-- -- 104 40 18 13 4
13.4 15 11 2
11.2 140 60
66XK IE3 *) 196Z *)
75
7.5 56
5.6
96W 196U
75
7.5 56
5.6 140 60 22 16 4
16,4 104 40
96Z *) 196X *)
24 17 9
17.9
96U 266W
104 40 20 14 9
14.9 140 60
96X *) 266Z *)
10 75
7.5 10 75
7.5
126W 266U
140 60 -- -- 27 20 1
20.1 104 40
126Z *) 266X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
New: Motor versions UK, XK for wet and dry installation with energy-saving motors
(Classification: NEMA MG1 “Energy Efficient Motors”).
32
KRT

KRT K 150-400 1750 rpm 6 inch


K 0 200 m#/h 400 600 800 1000 1200

0 100 l/s 200 300

Qmin
300
50
60
70
75
80 Qmax 80
TDH
ft
50
60
70
75
84 η [%]
50 80 86.1
60
70
75 84
200 80 84.8 84 60
50 84
60 80
70 83.6
75 80 m
ø404
50
60 80 75
79.3 ø382
70 40
75
75 ø360
75.6 75
100 75 70

70 ø330

ø300 20

40
0 1000 2000 3000 US.gpm 4000 5000

0 1000 IM.gpm 2000 3000 4000


280
ø404 200

ø382
200 kW
Power Input
ø360

hp
ø330 100

100 ø300

20
0 1000 2000 3000 US.gpm 4000 5000
Free passage K43191--00
3” (76 mm) Flow

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC

654U 1304WN
83 61 9
61.9 104 40 168 125 3
125.3 140 60
654X *) 1304ZN *)
804WN 1304UN
100 74 6
74.6 140 60 174 129 8
129.8 104 40
804ZN *) 1304XN *)
804UN 1554WN
107 79 8
79.8 104 40 194 144 7
144.7 140 60
804XN *) 1554ZN *)
954WN 1554UN
121 90 2
90.2 140 60 208 155 1
155.1 104 40
954ZN *) 1554XN *)
954UN
127 94 7
94.7 104 40
954XN *)
1104WN
134 99 9
99.9 140 60
1104ZN *)
1104UN
148 110 4
110.4 104 40
1104XN *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

33
KRT

KRT K 150-400 1160 rpm 6 inch


K 0 200 m#/h 400 600 800

0 50 l/s 100 150 200


140
Qmin
40
50
60
70
120 75
50
60
70
80

84
η [%]
75
100 50 80 84.8 30
60
70
84
75
TDH 80
83.5
50 80 m
80 60
70 82.3
80 75
75 ø404
50 80 75 20
60
60 78 ø382
70 75

ft 75 ø360
74.3
70
40 ø330
70
10
ø300
20
0 500 1000 1500 2000 2500 3000 3500
US.gpm
0 1000 IM.gpm 2000

80 ø404 60

kW
ø382
60
Power Input
ø360 40
hp

40 ø330

ø300
20
20

5
0 500 1000 1500 2000 2500 3000 3500
US.gpm
Flow K43190--00
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC

206U 406U
104 40 104 40
206X *) 406X *)
24 17 9
17.9 50 37 3
37.3
266W 506W
140 60 140 60
266Z *) 506Z *)
266U 506U
104 40 65 48 5
48.5 104 40
266X *) 506X *)
30 22 4
22.4
326W 606WN
140 60 140 60
326Z *) 606ZN *)
80 59 7
59.7
326U 606UN
104 40 104 60
326X *) 606XN *)
40 29 8
29.8
406W
140 60
406Z *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

34
KRT

KRT K 150-401 1750 rpm 6 inch


3
K 0 200 400 m /h 600 800 950

0 50 100 150 l/s 200 250 270

300
Qmin
60
80
70
TDH 75
78
60
70
80
82
83
η [%]
200 75 60
60 78 84
80
70 83
82 m
75 80
ft 60
81.7
78
78
70 80 ø404 40
80 78
80.1
60 75 80 75
76.9 78
100 70 75 ø375
75
71.2
70
ø350
ø330
20
ø310

40
0 500 1000 1500 2000 2500 3000 3500 4000 4400
US.gpm

200
ø404

kW
hp
ø375 100
Power Input

100 ø350

ø330
ø310

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4400
Free passage
3” (76 mm) Flow US.gpm K42589/3

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC 1104WN
134 99 9
99.9 115 85 8
85.8 140 60
504W 1104ZN *)
50 37 3
37.3 -- -- 140 60
504Z *) 1104UN
148 110 4
110.4 125 93 2
93.2 104 40
504U 1104XN *)
104 40
504X *) 1304WN
65 48 5
48.5 56 41 8
41.8 168 125 3
125.3 125 93 2
93.2 140 60
654W 1304ZN *)
140 60
654Z *) 1304UN
174 129 8
129.8 150 111 9
111.9 104 40
654U 1304XN *)
83 61 9
61.9 74 55 2
55.2 104 40
654X *) 1554WN
194 144 7
144.7 150 111 9
111.9 140 60
804WN 1554ZN *)
100 74 6
74.6 75 55 9
55.9 140 60
804ZN *) 1554UN
208 155 1
155.1 175 130 5
130.5 104 40
804UN 1554XN *)
107 79 8
79.8 90 67 1
67.1 104 40
804XN *) 1754WN
-- -- 175 130 5
130.5 140 60
954WN 1754ZN *)
121 90 2
90.2 95 70 8
70.8 140 60
954ZN *) 1754UN
-- -- 200 149 1
149.1 104 40
954UN 1754XN *)
127 94 7
94.7 100 74 6
74.6 104 40
954XN *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D


35
KRT

KRT K 150-401 1160 rpm 6 inch


3
K 0 200 400 m /h 600

0 50 100 l/s 150 180


140
Qmin 40

50
120
60
69
75
50
50 78
100 m
60
69
80

82
η [%]
50 75
TDH 82.7
80 60 78
82
69
ft 80 80
50
50
75 80.4 78
60
80 20
78 ø404
60 69 78
50 78.8
60 75
75 78
75.6 75 ø375
69 75
40 69.8
69 69 ø350
ø330
ø310
20

0 500 1000 1500 2000 2500 2900


US.gpm

60
ø404
40

40 ø375 kW
Power Input

hp
ø350
20
ø330
20
ø310

0 0
0 500 1000 1500 2000 2500 2900
Flow
US.gpm
K42590/3
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

206U 406U
104 40 104 40
206X *) 406X *)
24 17 9
17.9 -- -- 50 37 3
37.3 48 35 8
35.8
266W 506W
140 60 140 60
266Z *) 506Z *)
266U 506U
-- -- 104 40 65 48 5
48.5 56 41 8
41.8 104 40
266X *) 506X *)
30 22 4
22.4
326W 606WN
30 22 4
22.4 140 60 -- -- 60 44 7
44.7 140 60
326Z *) 606ZN *)
326U
104 40
326X *)
40 29 8
29.8 36 26 8
26.8
406W
140 60
406Z *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

36
KRT

KRT K 151-401 1750 rpm 6 inch


3
K 0 200 400 m /h 600 800 950

0 50 100 150 l/s 200 250 270

300

Qmin
60 80
TDH 250
65
70
74 η [%]
78
80
60 80.5
65
70 ø380
200 74
60
78
60
ft 65 78.8
70 78 m
74
150 75.7 74
60
65 70
70 74 ø360 40
74 74.2
74
ø330
100
ø300
80 25
0 500 1000 1500 2000 2500 3000 3500 4000 4400
US.gpm

200 ø380
ø360
kW
Power Input hp
ø330 100

100 ø300

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4400
US.gpm K43015
Flow
Free passage 3 1/8” (80 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

804WN 1304WN
100 74 6
74.6 75 55 9
55.9 140 60 168 125 3
125.3 125 93 2
93.2 140 60
804ZN *) 1304ZN *)
804UN 1304UN
107 79 8
79.8 90 67 1
67.1 104 40 174 129 8
129.8 150 111 9
111.9 104 40
804XN *) 1304XN *)
954WN 1554WN
121 90 2
90.2 95 70 8
70.8 140 60 194 144 7
144.7 150 111 9
111.9 140 60
954ZN *) 1554ZN *)
954UN 1554UN
127 94 7
94.7 100 74 6
74.6 104 40 208 155 1
155.1 175 130 5
130.5 104 40
954XN *) 1554XN *)
1104WN 1754WN
134 99 9
99.9 115 85 8
85.8 140 60 -- -- 175 130 5
130.5 140 60
1104ZN *) 1754ZN *)
1104UN 1754UN
148 110 4
110.4 125 93 2
93.2 104 40 -- -- 200 149 1
149.1 104 40
1104XN *) 1754XN *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

37
KRT

KRT K 151-401 1160 rpm 6 inch


3
K 0 200 400 m /h 600 800

0 50 100 l/s 150 200 230


160

Qmin
140
60
65
70 40
TDH
120
74
78 η [%]
60
65 80
70 80.1
74 80
78
100 78 m
60 79.3
65
ft 70 74
74 78
70
80 60 74
65 77.5 65
70 70 ø408
74 74
74.4 ø380 20
60 74 70
60 65
70 ø360
72.8 70
ø330
70
40 ø300

30
0 500 1000 1500 2000 2500 3000 3500 3700
US.gpm

100 ø408
kW
Power Input hp ø380
50
ø360
50
ø330

ø300

0 0
0 500 1000 1500 2000 2500 3000 3500 3700
Flow
US.gpm
K43016
Free passage 3 1/8” (80 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

326U 606WN
104 40 80 59 7
59.7 60 44 7
44.7 140 60
326X *) 606ZN *)
40 29 8
29.8 36 26 8
26.8
406W 606UN
140 60 80 59 7
59.7 70 52 2
52.2 104 40
406Z *) 606XN *)
406U 806WN
104 40 100 74 6
74.6 75 55 9
55.9 140 60
406X *) 806ZN *)
50 37 3
37.3 48 35 8
35.8
506W 806UN
140 60 107 79 8
79.8 90 67 1
67.1 104 40
506Z *) 806XN *)
506U 1006WN
65 48 5
48.5 56 41 8
41.8 104 40 -- -- 100 74 6
74.6 140 60
506X *) 1006ZN *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

38
KRT

KRT K 200-315 1160 rpm 8 inch


3
K 0 200 400 m /h 600 800 950

0 50 100 150 l/s 200 250 270

60

Qmin
70
75
80

TDH
40 82
84.5
η [%]
85.1
70
75
10
ft 80
84.5
82
84.1 82
70 80
75
80 82
82
20 82.9 80
75
70 ø295
75 82 m
80 75
79.2 ø259
75
75 ø236
ø211

0 0
0 500 1000 1500 2000 3000 3500 4000 4300
US.gpm

28
20
hp ø295

Power Input
20

ø259

10
ø236
10
ø211

4
0 500 1000 1500 2000 3000 3500 4000 4300
Flow
US.gpm
K42103/3
Free passage 2 3/4” (70 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

96U 196U
104 40 22 16 4
16.4 104 40
96X *) 196X *)
10 75
7.5 10 75
7.5 24 17 9
17.9
126W 266W
140 60 20 14 9
14.9 140 60
126Z *) 266Z *)
126U 266U
15 11 2
11.2 15 11 2
11.2 104 40 32 23 3
23.3 27 20 1
20.1 104 40
126X *) 266X *)
156U
20 14 9
14.9 -- -- 104 40
156X *)
196W
18 13 4
13.4 15 11 2
11.2 140 60
196Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

39
KRT

KRT K 200-316 1160 rpm 8 inch


3
K 0 200 400 m /h 600 800

0 50 100 l/s 150 200 240


60

Qmin 15

70
75
40
70
75
80
82 η [%]
TDH 83.8 10
80
ft 82
70
75 82.7 82

80 82 80 m
81.6 80
70
20 75 80 75
77.6 75
75
5
70 70 ø305
71.9 75
70 ø295
70 70
ø270
ø249
ø230
0 0
0 500 1000 1500 2000 2500 3000 3500 3900
US.gpm

24

20
ø305
kW
Power Input hp ø295
10

10 ø270

ø249

ø230

0 0
0 500 1000 1500 2000 2500 3000 3500 3900
Flow US.gpm K42104/3
Free passage 4” (100 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

66UK IE3 196W


-- -- 104 40 18 13 4
13.4 15 11 2
11.2 140 60
66XK IE3 *) 196Z *)
75
7.5 56
5.6
96W 196U
75
7.5 56
5.6 140 60 22 16 4
16.4 104 40
96Z *) 196X *)
24 17 9
17.9
96U 266W
104 40 20 14 9
14.9 140 60
96X *) 266Z *)
10 75
7.5 10 75
7.5
126W 266U
140 60 -- -- 27 20 1
20.1 104 40
126Z *) 266X *)
126U
15 11 2
11.2 15 11 2
11.2 104 40
126X *) New:
156U
20 14 9
14.9 -- -- 104 40 Motor versions UK, XK for wet and dry installation
156X *)
with energy-saving motors
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D (Classification: NEMA MG1 “Energy Efficient Motors”).

40
KRT

KRT K 200-330 1750 rpm 8 inch


3
K 0 200 400 600 m /h 800 1000 1200 1400

0 100 200 l/s 300 380


190

Qmin
TDH 150 60
65
70
75 40
ft 60

60
65
70
75
80
83
η [%]
65
84
100 70 80 m
60 75 83
65
82.9
70 80
60 80
75 81.5
65 80 ø326
70 20
80 80 ø310
75
75.8 ø296
50 75 ø281
ø266

30
0 1000 2000 3000 4000 5000 6000
US.gpm

140
ø326
100

hp
Power Input
ø310
100 kW

ø296

ø281

ø266 50

50
0 1000 2000 3000 4000 5000 6000
Flow US.gpm
Free passage 2 3/
4” (70 mm) K42086/2

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

654U 1104WN
104 40 134 99 9
99.9 115 85 8
85.8 140 60
654X *) 1104ZN *)
65 48 5
48.5 -- --
654W 1104UN
140 60 148 110 4
110.4 125 93 2
93.2 104 40
654Z *) 1104XN *)
654U 1304WN
83 61 9
61.9 74 55 2
55.2 104 40 168 125 3
125.3 125 93 2
93.2 140 60
654X *) 1304ZN *)
804WN 1304UN
100 74 6
74.6 75 55 9
55.9 140 60 174 129 8
129.8 150 111 9
111.9 104 40
804ZN *) 1304XN *)
804UN 1554WN
107 79 8
79.8 90 67 1
67.1 104 40 -- -- 150 111 9
111.9 140 60
804XN *) 1554ZN *)
954WN
121 90 2
90.2 95 70 8
70.8 140 60
954ZN *)
954UN
127 94 7
94.7 100 74 6
74.6 104 40
954XN *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D


41
KRT

KRT K 200-330 1160 rpm 8 inch


3
K 0 200 400 m /h 600 800 900

0 50 100 l/s 150 200 250

80

Qmin
50
20
60
65
60 50 70
75
TDH
ft
50
60
65
70
78
80
η [%] m
60
75
65 81.6
50 78
70
80
40 60
75 80
50 65 80.5
70 78 80 78
60 79.1 10
75 78 ø326
65
78 ø310
70 77.6

73.4 75 ø296
ø281
20 ø266

0 500 1000 1500 2000 2500 3000 3500 4000


US.gpm

40 30
ø326

hp
kW
Power Input ø310

30

ø296 20

ø281

20 ø266

16
0 500 1000 1500 2000 2500 3000 3500 4000
Flow
US.gpm
K42087/2
Free passage 2 3/4” (70 mm)
MOTOR RATING MAX. MOTOR CODE
MOTOR RATING MAX. MOTOR CODE Material LIQUID TEMP.
TEMP
Material LIQUID TEMP.
TEMP
G, G1, GH, H C1, C2
G, G1, GH, H C1, C2 Hp kW Hp kW oF oC
Hp kW Hp kW oF oC
406U
206U 104 40
104 40 406X *)
206X *) -- -- 48 35 8
35.8
24 17 9
17.9 -- -- 506W
266W 140 60
140 60 506Z *)
266Z *)
266U
-- -- 104 40
266X *)
30 22 4
22.4
326W
30 22 4
22.4 140 60
326Z *)
326U
104 40
326X *)
40 29 8
29.8 36 26 8
26.8
406W
140 60
406Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

42
KRT

KRT K 200-400 1750 rpm 8 inch


K 0 500 m#/h 1000 1500

0 100 l/s 200 300 400


240
Qmin
50
60
200 70 60
75
TDH 80
50
60 83 η [%] m
70
84.2
150 75
50 80 83 Qmax
60
40
ft 70 82 80
75
75
80
100 80
80.2 70
80 75 ø360
70
75
70 20
ø330
50 60

ø300

20
0 1000 2000 3000 4000 5000 6000 7000
US.gpm
0 1000 IM.gpm 2000 3000 4000 5000
240

ø360 160
200
Power Input
kW

hp
ø330
100

100
ø300

40
40
0 1000 2000 3000 4000 5000 6000 7000
Flow
US.gpm
K43187--00
Free passage 3 1/8” (80 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC

804WN 1304WN
100 74 6
74.6 140 60 168 125 3
125.3 140 60
804ZN *) 1304ZN *)
804UN 1304UN
107 79 8
79.8 104 40 174 129 8
129.8 104 40
804XN *) 1304XN *)
954WN 1554WN
121 90 2
90.2 140 60 194 144 7
144.7 140 60
954ZN *) 1554ZN *)
954UN 1554UN
127 94 7
94.7 104 40 208 155 1
155.1 104 40
954XN *) 1554XN *)
1104WN
134 99 9
99.9 140 60
1104ZN *)
1104UN
148 110 4
110.4 104 40
1104XN *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

43
KRT

KRT K 200-400 1160 rpm 8 inch


K 0 200 m#/h 400 600 800 1000

0 100 l/s 200 300


140

Qmin 40

120 50
60
70
75

TDH
100
50
60
70
75
80
83 η [%] m
50 80 84.7
60
70 83
75 83
80 80
83.8 Qmax
50 80
60 83
70 82.8 80 75
75 20
50 ø408
60 60 80 80 75
70 80.7
75 ø385
ft 80 75

78.9 70
75
40 ø360
70
75
70 60
60
ø330
20
ø300

5
0 1000 2000 3000 US.gpm 4000 5000

0 1000 IM.gpm 2000 3000 4000

ø408
100

ø385
Power Input hp
50
ø360

50
ø330
kW
ø300

0 0
0 1000 2000 3000 US.gpm 4000 5000
Free passage 3 1/8” (80 mm) Flow K43186--00

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC

206U 506W
104 40 50 37 3
37.3 140 60
206X *) 506Z *)
24 17 9
17.9
266W 506U
140 60 65 48 5
48.5 104 40
266Z *) 506X *)
266U 606WN
104 40 140 60
266X *) 606ZN *)
30 22 4
22.4 80 59 7
59.7
326W 606UN
140 60 104 60
326Z *) 606XN *)
326U 806WN
104 40 100 74 6
74.6 140 60
326X *) 806ZN *)
40 29 8
29.8
406W 806UN
140 60 107 79 8
79.8 104 40
406Z *) 806XN *)
406U 1006WN
50 37 3
37.3 104 40 121 90 2
90.2 140 60
406X *) 1006ZN *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D


44
KRT

KRT K 200-401 1750 rpm 8 inch


3
K 0 200 400 600 m /h 800 1000 1200

0 100 200 l/s 300 340


250

Qmin
60
65
200 70
60
TDH
75

60
65
78

80
η [%]
70
80.8
150 75
78 80

ft
60 ø360 40
65
80
70
75
78 m
100 78
78.6
78 ø330

75
20
ø300
50

0 1000 2000 3000 4000 5000 5400


US.gpm

200 ø360
kW
Power Input
hp
ø330
100

100 ø300

20
20
0 1000 2000 3000 4000 5000 5400
Flow
US.gpm
K43011/1
Free passage 3 1/8” (80 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW oF oC Hp kW oF oC
Hp kW Hp kW
804WN 1304WN
100 74 6
74.6 75 55 9
55.9 140 60 168 125 3
125.3 125 93 2
93.2 140 60
804ZN *) 1304ZN *)
804UN 1304UN
107 79 8
79.8 90 67 1
67.1 104 40 174 129 8
129.8 150 111 9
111.9 104 40
804XN *) 1304XN *)
954WN 1554WN
121 90 2
90.2 95 70 8
70.8 140 60 194 144 7
144.7 150 111 9
111.9 140 60
954ZN *) 1554ZN *)
954UN 1554UN
127 94 7
94.7 100 74 6
74.6 104 40 208 155 1
155.1 175 130.5
130 5 104 40
954XN *) 1554XN *)
1104WN 1754WN
134 99 9
99.9 115 85 8
85.8 140 60 -- -- 175 130.5
130 5 140 60
1104ZN *) 1754ZN *)
1104UN 1754UN
148 110 4
110.4 125 93 2
93.2 104 40 -- -- 200 149.1
149 1 104 40
1104XN *) 1754XN *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

45
KRT

KRT K 200-401 1160 rpm 8 inch


3
K 0 200 400 600 m /h 800 1000 1150

0 100 200 l/s 300


150

Qmin
40
60
65
70
TDH 75

100
60
65
70
78
80 η [%] m
75 81.7
60 78
65
70 80
75 80
80.6
78
ft 60
65 78
70 80
79.5 75
75 78
ø408 20
78
60 78 75
65 78.7
70 75
50 75
78 70
75 70
77.2 ø380
75 70 ø360
65
70 ø330
ø300

10
0 1000 2000 3000 4000 5000
US.gpm

100 ø408
kW
Power Input hp ø380
50
ø360
50
ø330

ø300

0 0
0 1000 2000 3000 4000 5000
US.gpm
K43012/1
Free passage 3 1/8” (80 mm) Flow

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

266U 606WN
104 40 80 59 7
59.7 60 44 7
44.7 140 60
266X *) 606ZN *)
30 22 4
22.4 -- --
326W 606UN
140 60 80 59 7
59.7 70 52 2
52.2 104 40
326Z *) 606XN *)
326U 806WN
104 40 100 74 6
74.6 75 55 9
55.9 140 60
326X *) 806ZN *)
40 29 8
29.8 36 26 8
26.8
406W 806UN
140 60 107 79 8
79.8 90 67 1
67.1 104 40
406Z *) 806XN *)
406U 1006WN
104 40 121 90 2
90.2 100 74 6
74.6 140 60
406X *) 1006ZN *)
50 37 3
37.3 48 35 8
35.8
506W
140 60
506Z *)
506U
65 48 5
48.5 56 41 8
41.8 104 40
506X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
46
KRT

KRT K 200-501 1160 rpm 8 inch


3
K 0 200 m /h 400 600 800 1000 1200

0 100 l/s 200 300


230

200 Qmin
60
65
70
76
TDH
65
70
80
81.5
η [%] m
76 81.9
150 81.5
65 80
70 80
80.6
76 80 76
40
ft 65
70
79 76 70
76
100 65 76 65
76.8 70
70 76
70 65
ø502
74 70 65 ø475
70 65 20
65 ø450
50 ø425
ø400

20
0 1000 2000 3000 US.gpm 4000 5000

200
ø502 140

kW
Power Input hp
ø475
100

ø450
100
ø425

ø400

20
20
0 1000 2000 3000 US.gpm 4000 5000
Flow K43054
Free passage 4 1/
8” (105 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

606WN 1206WN
80 59 7
59.7 140 60 161 120 1
120.1 140 60
606ZN *) 1206ZN *)
606UN 1206UN
80 59 7
59.7 104 40 161 120 1
120.1 104 40
606XN *) 1206XN *)
806WN 1406WN
100 74 6
74.6 140 60 188 140 2
140.2 140 60
806ZN *) 1406ZN *)
806UN 1406UN
107 79 8
79.8 104 40 188 140 2
140.2 104 40
806XN *) 1406XN *)
1006WN
121 90 2
90.2 140 60
1006ZN *)
1006UN
134 99 9
99.9 104 40
1006XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

47
KRT

KRT K 200-631 1160 rpm 8 inch


3
K 0 500 m /h 1000 1500

0 100 l/s 200 300 400


360

100
Qmin
300 65

TDH 65
70
70
75 η [%]
75 79
ft 79.5 m
65 79
70 79
75
79 80.4
65 80.5 75
200 70 79
75 81.3
79 80.5 ø622
65 80.5 75
70 79
75 81.2 ø600 50
65 80.5
70 79 75
78.8
75 ø570
75
76.7
75
75
ø540
100 70
70 ø510
ø480

40
0 1000 2000 3000 4000 5000 6000 7000
US.gpm

500

ø622
400
Power Input ø600

hp
ø570 200
ø540
200
ø510
ø480 kW

0 0
0 1000 2000 3000 4000 5000 6000 7000
Flow
US.gpm
Free passage 4 1/8” (105 mm) K43073

MOTOR RATING MAX. MOTOR CODE G, G1 MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP LIQUID TEMP.
Hp kW oF oC
G, G1
Hp kW oF oC 1906UN
255 190 2
190.2 104 40
1206WN 1906XN *)
161 120 1
120.1 140 60 2256WN
1206ZN *) 268 199 8
199.8 140 60
1206UN 2256ZN *)
161 120 1
120.1 104 40 2256UN
1206XN *) 300 223 7
223.7 104 40
1406WN 2256XN *)
188 140 2
140.2 140 60 2606WN
1406ZN *) 315 234 9
234.9 140 60
1406UN 2606ZN *)
188 140 2
140.2 104 40 2606UN
1406XN *) 350 261 0
261.0 104 40
1656WN 2606XN *)
215 160 3
160.3 140 60 3206WN
1656ZN *) 389 290 1
290.1 140 60
1656UN 3206ZN *)
221 164 8
164.8 104 40 3206UN
1656XN *) 430 320 7
320.7 104 40
1906WN 3206XN *)
228 170 0
170.0 140 60 3606WN
1906ZN *) 436 325 1
325.1 140 60
3606ZN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

48
KRT

KRT K 200-631 875 rpm 8 inch


3
K 0 200 m /h 400 600 800 1000 1200

0 100 l/s 200 300


200
60

Qmin
65
70 m
TDH

150
65
70
75
η [%]
75
78.3
65
70 40
75 79
ft 79.2
79 79 75
65
70
75 80
75 ø622
100 79 79
79.9 ø600
79 75

75 ø570

20
ø540

50
0 1000 2000 3000 4000 5000
US.gpm

200
ø622 140

kW
hp ø600
Power Input
100
ø570

100 ø540

20
20
0 1000 2000 3000 4000 5000
Flow
US.gpm
K43074
Free passage 4 1/8” (105 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

908WN 1308WN
121 90 2
90.2 140 60 174 129 8
129.8 140 60
908ZN *) 1308ZN *)
908UN 1308UN
121 90 2
90.2 104 40 174 129 8
129.8 104 40
908XN *) 1308XN *)
1108WN 1508WN
148 110 4
110.4 140 60 200 149 1
149.1 140 60
1108ZN *) 1508ZN *)
1108UN 1508UN
148 110 4
110.4 104 40 200 149 1
149.1 104 40
1108XN *) 1508XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

49
KRT

Closed non-clogging impellers 10” & 12”

KRT 250, 300 K--Impeller


with K-Impeller
K
4--pole (1750 rpm)
6--pole (1160 rpm)
8--pole (875 rpm)

200 300 400 500 m3/h 1000 2000 3000


40 50 l/s 100 200 300 400 500
400
100
300

250--630/ 8p 250--630/ 6p
200
50
300--503/ 6p
40
100 250--401/ 6p 30

250--400/ 300--500/ 8p 20
4p
50
250--400/ 6p
40
10
30
H
250--400/ 8p 300--400/ 6p [m]
20 300--401/ 6p
5
4
10 300--400/ 8p 3
TDH 300--401/ 8p
[ft] 2
5
500 Q[US.gpm] 1000 2000 3000 4000 5000 10000 14000
Flow

0W 382 468--02

50
KRT

KRT K 250-400 1750 rpm 10 inch


3
K 0 500 1000 m /h 1500 1700

0 100 200 l/s 300 400 480


240

200 Qmin 60
60
TDH
68

150
60
68
74
78
80
η [%]
74
81.3
ft 78 40
60 ø360
68 79.3

100 60
74 78 m
75.5
68 74
74
70.1
68
68 20
68
50 60 ø340
60
ø310
ø290

10
0 1000 2000 3000 4000 5000 6000 7000 7800
US.gpm

200 150
ø360

hp
Power Input kW
ø340
150

100

ø310
100
ø290
60
70
0 1000 2000 3000 4000 5000 6000 7000 7800
Flow
US.gpm
K42018/2
Free passage 3 3/8” (85 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

804WN 1304WN
100 74 6
74.6 75 55 9
55.9 140 60 168 125 3
125.3 125 93 2
93.2 140 60
804ZN *) 1304ZN *)
804UN 1304UN
107 79 8
79.8 90 67 1
67.1 104 40 174 129 8
129.8 150 111 9
111.9 104 40
804XN *) 1304XN *)
954WN 1554WN
121 90 2
90.2 95 70 8
70.8 140 60 194 144 7
144.7 150 111 9
111.9 140 60
954ZN *) 1554ZN *)
954UN 1554UN
127 94 7
94.7 100 74 6
74.6 104 40 208 155 1
155.1 175 130 5
130.5 104 40
954XN *) 1554XN *)
1104WN 1754WN
134 99 9
99.9 115 85 8
85.8 140 60 -- -- 175 130 5
130.5 140 60
1104ZN *) 1754ZN *)
1104UN 1754UN
148 110 4
110.4 125 93 2
93.2 104 40 -- -- 200 149 1
149.1 104 40
1104XN *) 1754XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

51
KRT

KRT K 250-400 1160 rpm 10 inch


3
K 0 200 400 600 m /h 800 1000 1200

0 100 200 l/s 300 340


110

100 30

Qmin
TDH 60
80 68
74

60
78
80
η [%] 20
68
60 74
81.4

60 80
ft 78
m
68 78.3 78
78
74
40 60 74
74.5
68 74 74 68
69.1 10
68 ø370
68 68
60 ø340
20 60
ø310
ø290

5
0 1000 2000 3000 4000 5000 5600
US.gpm

70

60
ø370 kW

Power Input 40
hp

ø340
40

ø310
20
ø290
20

0 1000 2000 3000 4000 5000 5600


Flow
US.gpm
K42019/2
Free passage 3 3/8” (85 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

266U 606WN
104 40 80 59 7
59.7 60 44 7
44.7 140 60
266X *) 606ZN *)
30 222 4
222.4 -- --
326W 606UN
140 60 80 59 7
59.7 70 52 2
52.2 104 40
326Z *) 606XN *)
326U 806WN
104 40 100 74 6
74.6 75 55 9
55.9 140 60
326X *) 806ZN *)
40 29 8
29.8 36 26 8
26.8
406W
140 60
406Z *)
406U
104 40
406X *)
50 37 3
37.3 48 35 8
35.8
506W
140 60
506Z *)
506U
65 48 5
48.5 56 41 8
41.8 104 40
506X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
52
KRT

KRT K 250-400 875 rpm 10 inch


3
K 0 200 400 m /h 600 800 900

0 50 100 l/s 150 200 250


60

Qmin 15
60
68
40
60
73
77 η [%]
80
68
TDH 73 80.9 10
ft 80
60 77
68 77.8 77
m
73 77 73
60
74
20 73 68
68 73
68.6
68 68
68 ø370 5
60 ø340
60
ø310
ø290

0 0
0 500 1000 1500 2000 2500 3000 3500 4000
US.gpm

28
20
hp ø370

Power Input 20 kW

ø340

10
ø310

10 ø290

6
0 500 1000 1500 2000 2500 3000 3500 4000
Flow
US.gpm
K42020/2
Free passage 3 3/8” (85 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

108U 268U
104 40 104 40
108X *) 268X *)
13 97
9.7 -- -- 38 28 3
28.3 33 24 6
24.6
178W 358W
140 60 140 60
178Z *) 358Z *)
178U
22 16 4
16.4 104 40
178X *)
-- --
218W
20 14 9
14.9 140 60
218Z *)
218U
-- -- 104 40
218X *)
25 18 7
18.7
268W
25 18 7
18.7 140 60
268Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

53
KRT

KRT K 250-401 1160 rpm 10 inch


3
K 0 500 m /h 1000 1400

0 100 200 l/s 300 400


130

120

Qmin
100 60
TDH 68
74
60
68
74
77
79 η [%]
80 60
77
79 80.1
68
74 80.1 79
60 77 20
68
60 78.1 79
77
60 74 77 74
ft 68 74.7 77
74
74 74
72 ø408
40 60 68
68
64.2
68
68 ø390 m
60
60 60 ø370
60
20 ø350
ø330
ø310
0 0
0 1000 2000 3000 4000 5000 6000 6600
US.gpm

100
ø408
kW
Power Input
hp ø390

50
ø370

50
ø350

ø330

ø310

10
10
0 1000 2000 3000 4000 5000 6000 6600
Flow
US.gpm
K42586/1
Free passage 4 1/8” (105 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

326U 606WN
104 40 80 59 7
59.7 60 44 7
44.7 140 60
326X *) 606ZN *)
40 29 8
29.8 36 26 8
26.8
406W 606UN
140 60 80 59 7
59.7 70 52 2
52.2 104 40
406Z *) 606XN *)
406U 806WN
104 40 100 74 6
74.6 75 55 9
55.9 140 60
406X *) 806ZN *)
50 37 3
37.3 48 35 8
35.8
506W 806UN
140 60 107 79 8
79.8 90 67 1
67.1 104 40
506Z *) 806XN *)
506U 1006WN
65 48 5
48.5 56 41 8
41.8 104 40 121 90 2
90.2 100 74 6
74.6 140 60
506X *) 1006ZN *)
1006UN
134 99 9
99.9 110 82 104 40
1006XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

54
KRT

KRT K 250-630 1160 rpm 10 inch


3
K 0 500 m /h 1000 1500

0 100 l/s 200 300 400 500


400

Qmin

TDH
60
68
74
η [%] 100
78
300 80
60
68 81.9
74
78
80 ø630
ft 60
68 m
81.7
74
78 80
ø590
80
200 60 80.6
68
80
74
78 ø550
50
78.8
78

74
ø500
100

0 1000 2000 3000 4000 5000 6000 7000 8000


US.gpm

700
ø630
600

Power Input 400


ø590
hp

ø550
400 kW

ø500
200

200

100
0 1000 2000 3000 4000 5000 6000 7000 8000
Flow US.gpm
K43052
Free passage 3 1/2” (90 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

2256WN 3606UN
268 199 8
199.8 140 60 480 357 9
357.9 104 40
2256ZN *) 3606XN *)
2256UN 4006WN
300 223 7
223.7 104 40 483 360 2
360.2 140 60
2256XN *) 4006ZN *)
2606WN 4006UN
315 234 9
234.9 140 60 536 399 7
399.7 104 40
2606ZN *) 4006XN *)
2606UN 4406WN
350 261 0
261.0 104 40 536 399 7
399.7 140 60
2606XN *) 4406ZN *)
3206WN 4406UN
389 290 1
290.1 140 60 590 440 0
440.0 104 40
3206ZN *) 4406XN *)
3206UN 4806WN
430 320 7
320.7 104 40 590 440 0
440.0 140 60
3206XN *) 4806ZN *)
3606WN 4806UN
436 325 1
325.1 140 60 640 477 2
477.2 104 40
3606ZN *) 4806XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
55
KRT

KRT K 250-630 875 rpm 10 inch


3
K 0 200 m /h 400 600 800 1000 1200 1400

0 100 l/s 200 300 400

200 Qmin 60
60
68
η [%]
74
78
TDH 60
68 79.9
m
74
150 ø630
78
60
68 79.7
74 40
ft 78
ø590
78
60 78.6
68
78
100 74
ø550
76.8

74

ø500 20

50
0 1000 2000 3000 4000 US.gpm 5000 6000

300
ø630
200
hp
Power Input ø590

200 kW
ø550

ø500 100

100

40
0 1000 2000 3000 4000 US.gpm 5000 6000
Flow K43053
Free passage 3 1/2” (90 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

908WN 1508WN
121 90 2
90.2 140 60 200 149 1
149.1 140 60
908ZN *) 1508ZN *)
908UN 1508UN
121 90 2
90.2 104 40 200 149 1
149.1 104 40
908XN *) 1508XN *)
1108WN 1858WN
148 110 4
110.4 140 60 235 175 2
175.2 140 60
1108ZN *) 1858ZN *)
1108UN 1858UN
148 110 4
110.4 104 40 250 186 4
186.4 104 40
1108XN *) 1858XN *)
1308WN 2208WN
174 129 8
129.8 140 60 268 199 8
199.8 140 60
1308ZN *) 2208ZN *)
1308UN 2208UN
174 129 8
129.8 104 40 295 220 0
220.0 104 40
1308XN *) 2208XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

56
KRT

KRT K 300-400 1160 rpm 12 inch


3
K 0 500 m/h 1000 1500 2000

0 200 l/s 400 600


130

120

100
Qmin
TDH
60
68
60 74
80 68
74
80
80
83
η [%]
60 83 84.5
68 20
60 74 84.5 83
80 80
60 83
68 83
74 83.3 80
83 74
80
40 60 74 68
82 80
68
74 68
80 74 m
ft
ø384 ø408
79.1
74 68
74 68
20 68
60
60 ø358
ø330
ø300

0 0
0 2000 4000 6000 US.gpm 8000 10000

140
100

ø408
Power Input

100 ø384 kW

hp
ø358
50

50 ø330

ø300
30
0 2000 4000 6000 US.gpm 8000 10000
Free passage 4” (100 mm) Flow K41682/4

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

406U 606WN
104 40 80 59 7
59.7 60 44 7
44.7 140 60
406X *) 606ZN *)
50 37 3
37.3 48 35 8
35.8
506W 606UN
140 60 80 59 7
59.7 70 52 2
52.2 104 40
506Z *) 606XN *)
506U 100 74 6
74.6 75 55 9
55.9 140 60 806WN
65 48 5
48.5 56 41 8
41.8 104 40 806ZN *)
506X *)
107 79 8
79.8 90 67 1
67.1 104 40 806UN
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D 806XN *)
121 90 2
90.2 100 74 6
74.6 140 60 1006WN
1006ZN *)
134 99 9
99.9 110 82 104 40 1006UN
1006XN *)

57
KRT

KRT K 300-400 875 rpm 12 inch


3
K 0 500 1000 m /h 1500 1700

0 100 200 l/s 300 400 460


70
20

60
Qmin
TDH 60
m
60
68

68
74 η [%]
74 80
82
40 80
60 82 83.2
68
74 83.2 82
10
ft 80
60 80 82
68 80
74 82 74

80 80 74 68
60 80.7
20 68
74 80 68 60
74
77.8 ø408
74 68 ø384
74 68
68 60 ø358
60
ø330
ø300

0 0
0 1000 2000 3000 4000 5000 6000 7000 7600
US.gpm

55
40
ø408
hp
Power Input
ø384 kW
40

ø358
20

ø330
20
ø300

10
0 1000 2000 3000 4000 5000 6000 7000 7600
Flow
US.gpm K41683/4
Free passage 4” (100 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

178U 508WN
22 16 4
16.4 -- -- 104 40 67 50 50 37 3
37.3 140 60
178X *) 508ZN *)
218W 508UN
20 14 9
14.9 -- -- 140 60 67 50 60 44 7
44.7 104 40
218Z *) 508XN *)
218U 758WN
-- -- 104 40 100 74 6
74.6 75 55 9
55.9 140 60
218X *) 758ZN *)
25 18 7
18.7
268W
25 18 7
18.7 140 60
268Z *)
268U
104 40
268X *)
38 28 3
28.3 33 24 6
24.6
358W
140 60
358Z *)
358U
47 35 40 29 8
29.8 104 40
358X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
58
KRT

KRT K 300-401 1160 rpm 12 inch


3
K 0 500 1000 m /h 1500 1800

0 100 200 l/s 300 400 500


80

Qmin
20
60
65
70
60 75

60
65
70
78
80 η [%]
TDH ft 75 81.5 m
78
78.8 80
60
65
70 78
40 78
75
75
75.7
60 75
65 75
ø393 10
70
7070 ø371
70
ø350
20 ø331

0 1000 2000 3000 4000 5000 6000 7000 8000


US.gpm

90
ø393
80 60

hp
ø371 kW
Power Input
60
40
ø350

40
ø331

20
20

0 1000 2000 3000 4000 5000 6000 7000 8000


Flow
US.gpm
K43038
Free passage 5 5/16” (135 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2 G, G1, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

326U 606WN
104 40 80 59 7
59.7 60 44 7
44.7 140 60
326X *) 606ZN *)
40 29 8
29.8 36 26 8
26.8
406W 606UN
140 60 80 59 7
59.7 70 52 2
52.2 104 40
406Z *) 606XN *)
406U 806WN
104 40 100 74 6
74.6 75 55 9
55.9 140 60
406X *) 806ZN *)
50 37 3
37.3 48 35 8
35.8
506W 806UN
140 60 107 79 8
79.8 90 67 1
67.1 104 40
506Z *) 806XN *)
506U 1006WN
65 48 5
48.5 56 41 8
41.8 104 40 -- -- 100 74 6
74.6 140 60
506X *) 1006ZN *)

*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

59
KRT

KRT K 300-401 875 rpm 12 inch


3
K 0 200 400 600 m /h 800 1000 1200 1350

0 100 200 l/s 300 360


46

40
Qmin
60
65
70
75
78
η [%] 10
60
65
30 70 80
TDH 75 80.3
80
ft 77.6 m
60 78
65
70
75
20 74.4 75
60
65 ø393
68.8 70 ø371 5

ø350
ø331
10

0 1000 2000 3000 4000 5000 6000


US.gpm

40
ø393

kW
30 ø371
Power Input
20
hp
ø350
20
ø331
10
10
6
0 1000 2000 3000 4000 5000 6000
Flow
US.gpm
K43039
Free passage 5 5/16” (135 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1, GH, H C1, C2


Hp kW Hp kW oF oC

178U
22 16 4
16.4 -- -- 104 40
178X *)
218W
20 14 9
14.9 -- -- 140 60
218Z *)
218U
-- -- 104 40
218X *)
25 18 7
18.7
268W
25 18 7
18.7 140 60
268Z *)
268U
104 40
268X *)
38 28 3
28.3 33 24 6
24.6
358W
140 60
358Z *)
358U
47 35 40 29 8
29.8 104 40
358X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
60
KRT

KRT K 300-500 875 rpm 12 inch


3
K 0 500 1000 m /h 1500 1900

0 100 200 300 l/s 400 500

120

Qmin
60
100 30
TDH 70

60
75
78
η [%]

70 80
80 75 80.6
60 78 80

70 78.9 78
20
60 60 75 78 75

70 76.2 75
ft 70
75
m
72.4 70

40 70 70 ø504
ø480
60 10
60
ø450
ø430
20 6

0 1000 2000 3000 4000 5000 6000 7000 8000 8400


US.gpm

140
100
ø504
hp

Power Input
100 ø480 kW

ø450
50
ø430

50
30
30
0 1000 2000 3000 4000 5000 6000 7000 8000 8400
Flow US.gpm
K41687/2
Free passage 3 1/2” (90 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

508WN 1108WN
67 50 0
50.0 140 60 148 110 4
110.4 140 60
508ZN *) 1108ZN *)
508UN 1108UN
67 50 0
50.0 104 40 148 110 4
110.4 104 40
508XN *) 1108XN *)
758WN
100 74 6
74.6 140 60
758ZN *)
758UN
100 74 6
74.6 104 40
758XN *)
908WN
121 90 2
90.2 140 60
908ZN *)
908UN
121 90 2
90.2 104 40
908XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

61
KRT

KRT K 300-503 1160 rpm 12 inch


3
K 0 500 m /h 1000 1500

0 100 l/s 200 300 400 500


200
60

Qmin
60
70
TDH 60
75
78
80
η [%] m

70 82
150 75
60 78 82.7
80
70 82
75 81.8 40
80
ft 60 78
70 80 78
80.4 80
60 75
78
80 78 ø480
70
75 79.1 78 75
100 78 78
78.2 75
78 ø460
75
70
75
70 ø440
70
ø420
ø405 20

50
0 1000 2000 3000 4000 5000 6000 7000 8000
US.gpm

300
ø480
200
hp
Power Input ø460

200 ø440 kW

ø420
ø405
100

100

60
0 1000 2000 3000 4000 5000 6000 7000 8000
US.gpm
Flow K43137
Free passage 2” (50 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

1206WN 1906WN
161 120 1
120.1 140 60 228 170 0
170.0 140 60
1206ZN *) 1906ZN *)
1206UN 1906UN
161 120 1
120.1 104 40 255 190 2
190.2 104 40
1206XN *) 1906XN *)
1406WN 2256WN
188 140 2
140.2 140 60 268 199 8
199.8 140 60
1406ZN *) 2256ZN *)
1406UN 2256UN
188 140 2
140.2 104 40 300 223 7
223.7 104 40
1406XN *) 2256XN *)
1656WN 2606WN
215 160 3
160.3 140 60 315 234 9
234.9 140 60
1656ZN *) 2606ZN *)
1656UN 2606UN
221 164 8
164.8 104 40 350 261 104 40
1656XN *) 2606XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

62
KRT

Closed non-clogging impellers 14”, 16”, 20”, 24” & 30”

KRT 350, 400, 500, 600, 700 K--Impeller


with K-Impeller
K
6--pole (1160 rpm)
8--pole (875 rpm)
10--pole (700 rpm)
12--pole (585 rpm)

500 m3/h 1000 2000 3000 4000 5000


200 300 400 500 l/s 1000 2000
400
100
300

200 350--630/ 6p
350--710/ 8p consult factory
50
40
350--630/ 8p
100 30
400--630/ 8p
350--420/ 6p 350--636/ 8p 20
50
350--501/ 8p
40 600--710/ 12p
350--500/ 10p 350--500/ 8p 10
30 700--900/ 12p
400--500/ 8p H
500--630/ 8p [m]
20
5
500--630/ 10p 600--520/ 10p 4
400--500/ 10p
10 350--501/ 10p 3
TDH
[ft] 2
5
2000 3000 4000 5000 Q[US.gpm] 10000 20000 30000 40000
Flow

0W 382 469--02

63
KRT

KRT K 350-420 1160 rpm 14 inch


3
K 0 500 1000 m /h 1500 2000 2500

0 200 400 l/s 600 700

120

Qmin
50

TDH 100 60
30
50
60 70
75
70

80
50
60
75
80
82
80
82
η [%]
70
50 75 84
ft 60 80 83.3
82 85.1
70
75 84 20
50 82
60 80 84
60 82 85
70 80
75 83.1 84 82 ø435
82 ø416 m
79.7 82 80
80 ø395
40
75 ø376
10
ø355

20
0 2000 4000 6000 8000 10000 11500
US.gpm

200

ø435
hp
Power Input
kW
150 ø416

100
ø395

ø376
100
ø355
80 60
0 2000 4000 6000 8000 10000 11500
Flow US.gpm K42092/1
Free passage 4” (100 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

806WN 1206WN
100 74 6
74.6 140 60 161 120 1
120.1 140 60
806ZN *) 1206ZN *)
806UN 1206UN
107 79 8
79.8 104 40 161 120 1
120.1 104 40
806XN *) 1206XN *)
1006WN 1406WN
121 90 2
90.2 140 60 188 140 2
140.2 140 60
1006ZN *) 1406ZN *)
1006UN 1406UN
134 99 9
99.9 104 40 188 140 2
140.2 104 40
1006XN *) 1406XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

64
KRT

KRT K 350-500 1160 rpm 14 inch


K 0 1000 m#/h 2000 3000 4000

0 200 l/s 400 600 800 1000

200 60

Qmin
TDH m
60
150 70
75

η [%]
80
60 82 40
ft 84
70
75
85.2
80
60
100 82
84
70
75 83 82
80
60 80 82
70 81.3 80 75
75 80
75 ø508 20
78.7
75 70
50 75 70 ø475
70
ø445
ø410
20
0 2000 4000 6000 8000 10000 12000 14000 16000 18000
US.gpm
0 5000 IM.gpm 10000
400

ø508 280
hp
Power Input
kW
300

ø475 200

ø445
200

ø410 120
140
0 2000 4000 6000 8000 10000 12000 14000 16000 18000
Flow US.gpm K41689--05
Free passage 4 1/4” (110 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

1406WN 2256WN
140 60 268 199 8
199.8 140 60
1406ZN *) 2256ZN *)
188 140 2
140.2
1406UN 2256UN
104 40 300 223 7
223.7 104 40
1406XN *) 2256XN *)
1656WN 2606WN
215 160 3
160.3 140 60 315 234 9
234.9 140 60
1656ZN *) 2606ZN *)
1656UN 2606UN
221 164 8
164.8 104 40 350 261 104 40
1656XN *) 2606XN *)
1906WN
228 170 140 60
1906ZN *)
1906UN
225 190 2
190.2 104 40
1906XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

65
KRT

KRT K 350-500 875 rpm 14 inch


3
K 0 1000 2000 m /h 3000

0 200 400 l/s 600 800


115

100 30
Qmin
60
TDH
70
80 75

60 80

83
η [%]
70
75 84
20
60 60 80
83
70
ft 75
81.8
80 m
60
8080.1 80 75
40 70 80
75 75 ø508
77.5 75 10
70
75 70 ø475
70
ø445
20
ø410
4
10
0 2000 4000 6000 8000 10000 12000 14000
US.gpm

180

ø508
kW
150
Power Input
100
hp
ø475

100
ø445

ø410
50
60
0 2000 4000 6000 8000 10000 12000 14000
US.gpm
Flow K41690/3
Free passage 4 1/4” (110 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

758WN 1108WN
100 74 6
74.6 140 60 148 110 4
110.4 140 60
758ZN *) 1108ZN *)
758UN 1108UN
100 74 6
74.6 104 40 148 110 4
110.4 104 40
758XN *) 1108XN *)
908WN 1308WN
121 90 2
90.2 140 60 174 129 8
129.8 140 60
908ZN *) 1308ZN *)
908UN 1308UN
121 90 2
90.2 104 40 174 129 8
129.8 104 40
908XN *) 1308XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

66
KRT

KRT K 350-500 700 rpm 14 inch


3
K 0 500 1000 m /h 1500 2000 2400

0 200 400 l/s 600


75

20
Qmin
60
TDH 60
m
70
75

60 80 η [%]
70 83
75 83.3
40
83
60 80
70
75
81 80 10
ft
60 80
79.3 75
70
75 75 ø508
76.7 75 70
20 75 70
ø475
70
ø445
ø410

2
5
0 2000 4000 6000 8000 10000 11000
US.gpm

90

ø508
80 60

Power Input
hp

60 ø475 kW
40
ø445

40
ø410
25
30
0 2000 4000 6000 8000 10000 11000
US.gpm
Flow
Free passage K41691/3
4 1/4” (110 mm)

MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE

G, G1
Hp kW oF oC

4010UN
50 37 3
37.3 104 40
4010XN *)
6010WN
80 59 7
59.7 140 60
6010ZN *)
6010UN
80 59 7
59.7 104 40
6010XN *)
7510WN
100 74 6
74.6 140 60
7510ZN *)
7510UN
100 74 6
74.6 104 40
7510XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

67
KRT

KRT K 350-501 875 rpm 14 inch


3
K 0 500 m /h 1000 1500 2000 2500

0 200 l/s 400 600


80

Qmin

60
20
68
TDH
60 75
60
68 79
η [%]
60
75
ft 68 80.9 m
75 79
79.5 79
40 79
78.5
75
75 10
75
68
68
68 ø509
60
20 60 ø500

ø492

10
0 2000 4000 6000 8000 10000 12000
US.gpm

120

ø509 80
Power Input 100

hp ø500

80 60
ø492

60
40
50
0 2000 4000 6000 8000 10000 12000
Flow US.gpm
Free passage K43061
6 5/8” (170 mm)

MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE

G, G1
Hp kW oF oC

758WN
100 74 6
74.6 140 60
758ZN *)
758UN
100 74 6
74.6 104 40
758XN *)
908WN
121 90 2
90.2 140 60
908ZN *)
908UN
121 90 2
90.2 104 40
908XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

68
KRT

KRT K 350-501 700 rpm 14 inch


3
K 0 500 m /h 1000 1500 2000

0 200 l/s 400 600


54

50 15
Qmin
60
TDH m
40 68
60
68
75 η [%]
60 79
75
79.4
10
68
30 79
75
78.1
ft 77.1 75
75
75
20 68
68
68
ø509 5
60
60
ø500
10 ø492

6
0 2000 4000 6000 8000 10000
US.gpm

60
ø509
Power Input 40
hp
ø500

40 kW
ø492

20
25
0 2000 4000 6000 8000 10000
Flow US.gpm
Free passage K43062
6 5/8” (170 mm)

MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE

G, G1
Hp kW oF oC

4010UN
50 37 3
37.3 104 40
4010XN *)
6010WN
80 59 7
59.7 140 60
6010ZN *)
6010UN
80 59 7
59.7 104 40
6010XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

69
KRT

KRT K 350-630 875 rpm 14 inch


3
K 0 500 m /h 1000 1500 2000 2500

0 200 l/s 400 600 800


220

200 60
Qmin
TDH 60
65
70 m
73
150
60
60
65
70
76

79
η [%]
65 73
70 79.8
60 73
76
79 40
ft 65
70 76 77.4
76
73 76.5
60 76 ø630
76
65 75.1
100 70
73
ø600
73 73 ø580
74.2
70
73 ø550
70
20
ø500
50

0 2000 4000 6000 8000 10000 12000


US.gpm

500
350
ø630
400
Power Input ø600 kW
ø580
hp
ø550 200

200 ø500

50
50
0 2000 4000 6000 8000 10000 12000
US.gpm
Flow
Free passage K42889/1
5 5/16” (135 mm)

MOTOR RATING MAX. MOTOR G, G1 MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE LIQUID TEMP. CODE
Hp kW oF oC
G, G1
Hp kW oF oC 2208UN
295 220 0
220.0 104 40
1308WN 2208XN *)
174 129 8
129.8 140 60 2608WN
1308ZN *) 335 249 8
249.8 140 60
2608ZN *)
1308UN 2608UN
174 129 8
129.8 104 40 350 261 0
261.0 104 40
1308XN *) 2608XN *)
1508WN 3008WN
200 149 1
149.1 140 60 389 290 1
290.1 140 60
1508ZN *) 3008ZN *)
1508UN 3008UN
200 149 1
149.1 104 40 400 298 3
298.3 104 40
1508XN *) 3008XN *)
1858WN 3508WN
235 175 2
175.2 140 60 436 325 1
325.1 140 60
1858ZN *) 3508ZN *)
1858UN 3508UN
250 186 4
186.4 104 40 470 350 5
350.5 104 40
3508XN *)
1858XN *) 4008WN
2208WN 483 360 2
360.2 140 60
268 199 8
199.8 140 60 4008ZN *)
2208ZN *) 4008UN
535 398 9
398.9 104 40
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D 4008XN *)

70
KRT

KRT K 350-636 875 rpm 14 inch


3
K 0 1000 m /h 2000 3000

0 200 l/s 400 600 800


190

Qmin
70
75

TDH 150
80
83 η [%]
70 86
75 86.1
86
80
83 40
ft 84.6 83
70
75 80
80 83
83
83.7 80 ø595
100 70 83 m
75 75
80
80 70
82.3 ø565
75
80 70
75 ø540 20
70
ø510
50

0 2000 US.gpm 4000 6000 8000 10000 12000 14000


US.gpm

500
ø595
400
ø565
Power Input

hp ø540
200
ø510
200

kW

0 0
0 2000 4000 6000 8000 10000 12000 14000
US.gpm
Free passage 3” (75 mm) Flow
K43135

MOTOR RATING MAX. MOTOR G, G1 MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE LIQUID TEMP. CODE
Hp kW oF oC
G, G1
oF oC 2208UN
Hp kW 295 220 0
220.0 104 40
2208XN *)
1308WN 2608WN
174 129 8
129.8 140 60 335 249 8
249.8 140 60
1308ZN *) 2608ZN *)
1308UN 2608UN
174 129 8
129.8 104 40 350 261 0
261.0 104 40
1308XN *) 2608XN *)
1508WN 3008WN
200 149 1
149.1 140 60 389 290 1
290.1 140 60
1508ZN *) 3008ZN *)
1508UN 3008UN
200 149 1
149.1 104 40 400 298 3
298.3 104 40
1508XN *) 3008XN *)
1858WN 3508WN
235 175 2
175.2 140 60 436 325 1
325.1 140 60
3508ZN *)
1858ZN *) 3508UN
1858UN 470 350 5
350.5 104 40
250 186 4
186.4 104 40 3508XN *)
1858XN *) 4008WN
2208WN 483 360 2
360.2 140 60
268 199 8
199.8 140 60 4008ZN *)
2208ZN *) 4008UN
535 398 9
398.9 104 40
4008XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
71
KRT

KRT K 350-710 875 rpm 14 inch


3
K 0 500 m /h 1000 1500 2000 2500

0 200 l/s 400 600

250 Qmin
70
75

70
75
80
82
84
η [%]
TDH
200 80 84.9 60
70 82
75 ø730
80 83.3
70
75 82
82.7 82
m
70 80 80
150 75
82
81.3 80
75
70 80 40
ft 78.5
75 ø700
75 75
75.4 75 70
75 ø670
100
70
70
70 ø640

ø610
ø580 20

50
0 2000 4000 6000 8000 10000 12000
US.gpm

550 400
ø730 ø700

Power Input 400 ø670 kW

ø640
hp
ø610
200
ø580
200

50
0 2000 4000 6000 8000 10000 12000
Flow US.gpm
Free passage K43065
4 1/4” (110 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

2608WN 3508WN
335 249 8
249.8 140 60 436 325 1
325.1 140 60
2608ZN *) 3508ZN *)
2608UN 3508UN
350 261 0
261.0 104 40 470 350 5
350.5 104 40
2608XN *) 3508XN *)
3008WN 4008WN
389 290 1
290.1 140 60 483 360 2
360.2 140 60
3008ZN *) 4008ZN *)
3008UN 4008UN
400 298 3
298.3 104 40 535 398 9
398.9 104 40
3008XN *) 4008XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

72
KRT

KRT K 400-500 875 rpm 16 inch


3
K 0 1000 m /h 2000 3000

0 200 l/s 400 600 800 1000


100 30

Qmin
m
80 60
TDH
70
60 75

60
70
75
80 η [%] 20
60 70
82
75 80 82.9
60
82 82
ft 70 80 82.2
60 75 82 80
81.4
70
80 80
40 60 75 80.3 80 75
80
70
78.2 75 70
75 75 10
76.7 75 70
75 70 ø508
75 70
70
70 60 ø477
20 60 60
ø460
60
ø440
ø426
ø400

5
0 2000 4000 6000 8000 10000 12000 14000 16000
US.gpm

190

ø508

Power Input 150


ø477
100
hp
ø460

100 ø440 kW
ø426
ø400
50
60
0 2000 4000 6000 8000 10000 12000 14000 16000
Flow US.gpm
Free passage K43069
5 1/8” (130 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE LIQUID TEMP.
TEMP CODE
Material
G, G1 G, G1
Hp kW oF oC oF oC
Hp kW
758WN 1308WN
100 74 6
74.6 140 60 174 129 8
129.8 140 60
758ZN *) 1308ZN *)
758UN 1308UN
100 74 6
74.6 104 40 174 129 8
129.8 104 40
758XN *) 1308XN *)
908WN 1508WN
121 90 2
90.2 140 60 200 149 1
149.1 140 60
908ZN *) 1508ZN *)
908UN 1508UN
121 90 2
90.2 104 40 200 149 1
149.1 104 40
908XN *) 1508XN *)
1108WN
148 110 4
110.4 140 60
1108ZN *)
1108UN
148 110 4
110.4 104 40
1108XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

73
KRT

KRT K 400-500 700 rpm 16 inch


3
K 0 1000 m /h 2000 3000

0 200 l/s 400 600 800

60
Qmin
60
TDH
60
70
75
η [%]
70
40 60 75 80
70
75 80 81.9
60
70 81.2 10
80 80
ft 60 75 80.4
70 80
80
79.3 75
60 75
70 77.2 75 70
75 75
20 75.7 75 75 70
75 70 ø508
70 m
70
70 60 ø477
60 60
60 ø460
ø440
ø426
ø400

0 0
0 2000 4000 6000 8000 10000 12000
US.gpm

100

ø508

Power Input 80 60

ø477
hp
kW
ø460
60
ø440 40

ø426
40 ø400

30
0 2000 4000 6000 8000 10000 12000
US.gpm
Flow
Free passage K43070
5 1/8” (130 mm)

MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE

G, G1
Hp kW oF oC

4010UN
50 37 3
37.3 104 40
4010XN *)
6010WN
80 59 7
59.7 140 60
6010ZN *)
6010UN
80 59 7
59.7 104 40
6010XN *)
7510WN
100 74 6
74.6 140 60
7510ZN *)
7510UN
100 74 6
74.6 104 40
7510XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

74
KRT

KRT K 400-630 875 rpm 16 inch


3
K 0 1000 m /h 2000 3000 4000

0 200 l/s 400 600 800 1000 1200


190

TDH 150 Qmin


60

70
75
40
ft 60

70
80
82
η [%]
60
75
83.7
100 70 80 m
60 82
75
82.7 82
70 80 80
60 82
75 81.1
ø620
80
70 79.1 80 ø590 20
74.8 ø563
50 ø534
ø506

30
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000
US.gpm

500
ø620

Power Input
400 300
ø590
hp
kW
ø563
300
ø534 200
ø506

200
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000
Flow US.gpm
Free passage K43077
5 1/4” (132 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

1858WN 3008WN
235 175 2
175.2 140 60 399 290 1
290.1 140 60
1858ZN *) 3008ZN *)
1858UN 3008UN
250 186 4
186.4 104 40 400 298 3
298.3 104 40
1858XN *) 3008XN *)
2208WN 3508WN
268 199 8
199.8 140 60 436 325 1
325.1 140 60
2208ZN *) 3508ZN *)
2208UN 3508UN
295 220 0
220.0 104 40 470 350 5
350.5 104 40
2208XN *) 3508XN *)
2608WN 4008WN
335 249 8
249.8 140 60 483 360 2
360.2 140 60
2608ZN *) 4008ZN *)
2608UN 4008UN
350 261 0
261.0 104 40 535 398 9
398.9 104 40
2608XN *) 4008XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

75
KRT

KRT K 500-630 875 rpm 20 inch


3
K 0 1000 2000 3000 m /h 4000 5000 5400

0 500 l/s 1000 1500


120

Qmin
100 30
50
TDH
60
68
50
80 60
68
74
80
84
η [%]
74
50
60 80 85.3
68
20
60 74 82.8 84

50 80
ft 60 81.5
80 m
80
68
80
74
40 74
74
75.2
74 68
74
68
10
68
68 60
60
60
20 60 ø565
ø450 ø490 ø540

5
0 5000 10000 15000 20000 24000
US.gpm

300

200
hp
Power Input

200 kW
ø565

ø540

ø490 100

ø450
100
60
0 5000 10000 15000 20000 24000
Flow
US.gpm
K41694/2
Free passage 5 1/4” (133 mm)

MOTOR RATING MAX. MOTOR MOTOR RATING MAX. MOTOR


Material LIQUID TEMP.
TEMP CODE Material LIQUID TEMP.
TEMP CODE

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

1108WN 1858WN
148 110 4
110.4 140 60 235 175 2
175.2 140 60
1108ZN *) 1858ZN *)
1108UN 1858UN
148 110 4
110.4 104 40 250 186 4
186.4 104 40
1108XN *) 1858XN *)
1308WN 2208WN
174 129 8
129.8 140 60 268 199 8
199.8 140 60
1308ZN *) 2208ZN *)
1308UN 2208UN
174 129 8
129.8 104 40 295 220 0
220.0 104 40
1308XN *) 2208XN *)
1508WN 2608WN
200 149 1
149.1 140 60 335 249 8
249.8 140 60
1508ZN *) 2608ZN *)
1508UN 2608UN
200 149 1
149.1 104 40 350 261 0
261.0 104 40
1508XN *) 2608XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

76
KRT

KRT K 500-630 700 rpm 20 inch


3
K 0 1000 2000 m /h 3000 4000

0 200 400 600 l/s 800 1000 1150


80

Qmin 20
TDH 50
60
60
68
50
74
60
68
74
80
84
η [%] m
50
60 80 84.6
40 68 84
74 82.1

50 80 80
60 80 10
ft 80.7
68 80
74
74 74
74.5 74
74 68
20 68
68
68 60
60
60
60 ø565
ø490 ø540
ø450
5
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 19000
US.gpm

150

100
Power Input hp

100 kW
ø565

ø540

ø490
50
ø450
50
30
0 2000 4000 6000 8000 10000 12000 14000 16000 18000 19000
Flow US.gpm
K41695/2
Free passage 5 1/4” (133 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

6010WN 11010WN
80 59 7
59.7 140 60 148 110 4
110.4 140 60
6010ZN *) 11010ZN *)
6010UN 11010UN
80 59 7
59.7 104 40 148 110 4
110.4 104 40
6010XN *) 11010XN *)
7510WN
100 74 6
74.6 140 60
7510ZN *)
7510UN
100 74 6
74.6 104 40
7510XN *)
9010WN
121 90 2
90.2 140 60
9010ZN *)
9010UN
121 90 2
90.2 104 40
9010XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

77
KRT

KRT K 600-520 700 rpm 24 inch


3
K 2000 3000 m /h 4000 5000

400 600 l/s 800 1000 1200 1400

60

Qmin
70
TDH ft
75 15
70

70
75

80
80
η [%] m
40
75 83 82.7

80 84
70
83 80 10
75
82.2

80 80
80.2 75
80 80
75
70
75 ø532
20 75 ø503
ø487 5
ø457

10
6000 8000 10000 12000 14000 16000 18000 20000 22000
US.gpm

220

200 150

Power Input
hp
kW
ø532
150
ø503
100

ø487

100 ø457

80
6000 8000 10000 12000 14000 16000 18000 20000 22000
Flow US.gpm
K41696/4
Free passage 5 3/4” (145 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

11010WN
148 110 4
110.4 140 60
11010ZN *)
11010UN
148 110 4
110.4 104 40
11010XN *)
15010WN
200 149 1
149.1 140 60
15010ZN *)
15010UN
200 149 1
149.1 104 40
15010XN *)
19010WN
235 175 2
175.2 140 60
19010ZN *)
19010UN
255 190 2
190.2 104 40
19010XN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

78
KRT

KRT K 600-710 585 rpm 24 inch


3
K 2000 3000 m /h 4000 5000 6000

500 1000 l/s 1500

80
Qmin

TDH
70
75 η [%]
80 20
70
83
75
60 80
85
70
75 83
86.8
70 80
85
ft 75 83 85.3
m
85 85
80
84.6
83
83
82.2
40 83 80
80
80 80
ø715
ø693 10
75 ø670
ø648

20
5000 10000 15000 20000 25000
US.gpm

320
ø715
300

Power Input
hp
ø693 200

250
ø670
kW

ø648
200 150

5000 10000 15000 20000 25000


US.gpm
Flow K42892/1
Free passage 6 1/2” (165 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

19512UN
104 40
19512XN *)
260 193 9
193.9
23012WN
140 60
23012ZN *)
23012UN
104 40
23012XN *)
310 231 2
231.2
26512WN
140 60
26512ZN *)
26512UN
104 40
26512XN *)
355 264 7
264.7
30012WN
140 60
30012ZN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

79
KRT

KRT K 700-900 585 rpm 30 inch


3
K 0 2000 m /h 4000 6000 8000

0 500 l/s 1000 1500 2000 2500


90

80

TDH Qmin
60
20
68
60

60
74

79
η [%]
ft 68 m
74 81.2

60
40 76.1
68 79
71.3 74 10
74
68
68
60
ø764
20 ø694
ø637

10
0 5000 10000 15000 20000 25000 30000 35000 40000
US.gpm

400 300

Power Input
hp
kW
ø764
300

ø694 200

ø637

220
0 5000 10000 15000 20000 25000 30000 35000 40000
Flow US.gpm
K24894/1
Free passage 7 1/2” (190 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

19512WN 26512UN
260 193 9
193.9 140 60 104 40
19512ZN *) 26512XN *)
355 264 7
264.7
19512UN 30012WN
260 193 9
193.9 104 40 140 60
19512XN *) 30012ZN *)
23012WN 30012UN
295 220 0
220.0 140 60 400 298 3
298.3 104 40
23012ZN *) 30012XN *)
23012UN
310 231 2
231.2 104 40
23012XN *)
26512WN
335 249 8
249.8 140 60
26512ZN *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

80
KRT

Open single vane impeller 3”, 4”, 6”, 8” 10”& 12”

KRT 80, 100, 150, 200, 250, 300 D--Impeller


with D-Impeller
D
4--pole (1750 rpm)
6--pole (1160 rpm)
8--pole (875 rpm)

50 m3/h 100 200 300 400 500 1000


20 30 40 50 l/s 100 200 300 400
400
100
300

200
50
40
100--251/ 4p
100 30

80--315/ 4p 20
150--401/ 6p
50
150--400/ 6p
40
100--315/ 4p 10
30 100--316/ 6p
200--400/ 6p
H
150--315/ 6p [m]
20 100--251/ 6p
5
200--315/ 6p 4
250--400/ 6p
10 150--251/ 6p 3
TDH
250--400/ 8p 300--400/ 8p
[ft] 2
5
200 300 400 500 Q[US.gpm] 1000 2000 3000 4000 5000 7000
Flow

0W 386 697--02

81
KRT

KRT D 80-315 1750 rpm 3 inch


3
D 0 50 m/h 100 150 200

0 20 l/s 40 60

120
Qmin
55
60
100 63
30
66
55
60 68

55
60
63
66 η [%] m
TDH 80 63
68 70
55 66
ft 60 68.9
63 68 68 20
68
60 66
64.9
66
66 63
63 63 60
63 60
60 55
40 60
55 ø260
ø230 ø242 ø250 10

25
0 200 400 600 US.gpm 800 1000

18
ø260
15
ø250
10
Power Input hp
ø242

10 ø230 kW

5
5

3
0 200 400 600 US.gpm 800 1000
Flow K43099/1
Free passage 2 1/
2” (65 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

234W
20 14 9
14.9 140 60
234Z *)
234U
28 20 9
20.9 104 40
234X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

82
KRT

KRT D 100-251 1750 rpm 4 inch


D 0 100 m#/h 200 300 400

0 20 l/s 40 60 80 100 120


120

100 30

60
Qmin m
80

TDH 60
70

75
η [%] 20
77
60 70
Qmax
78.1
60
ft 75 77
70 75.2 75
75
40 72.7 70
70
70
10
60
60 ø265
60
20 ø250
ø234

5
0 200 400 600 800 1000 1200 1400 1600 1800
US.gpm
0 500 IM.gpm 1000 1500
23

ø265
20 15

Power Input
hp
kW

ø250
15

10

ø234
10
0 200 400 600 800 1000 1200 1400 1600 1800
Flow US.gpm
K43200--00
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

54UK IE3 114U


104 40
54XK IE3*) 114X *)
104 40 15 11 2
11.2
54U 164W
75
7.5 56
5.6 140 60
54X *) 164Z *)
74W 164U
140 60 104 40
74Z *) 164X *)
20 14 9
14.9
74UK IE3 214W
140 60
74XK IE3*) 214Z *)
104 40
74U 194U
10 75
7.5 25 18 6
18.6 104 40
74X *) 194X *)
114W
140 60
114Z *) New:
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D Motor versions UK, XK for wet and dry installation
with energy-saving motors
(Classification: NEMA MG1 “Energy Efficient Motors”).
83
KRT

KRT D 100-251 1160 rpm 4 inch


3
D 0 50 m /h 100 150 200 250

0 20 l/s 40 60 80
50 15

m
40
Qmin
65 10
TDH 30
65
70

75
η [%]
ft 70 76

65 75
20 73.2
70 70
70.7 70 5
70 65
65
65 ø265
10
ø250
ø234

2
0 200 400 600 800 US.gpm 1000 1200

6
ø265

4
Power Input hp

ø250
4 kW

ø234

2
2.5
0 200 400 600 800 US.gpm 1000 1200
Flow K43119
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

46U
46X *) New:
104 40
46UK IE3 Motor versions UK, XK for wet and dry installation
65
6.5 48
4.8
46XK IE3 *) with energy-saving motors
66W (Classification: NEMA MG1 “Energy Efficient Motors”).
140 60
66Z *)
66U
140 60
66X *)
75
7.5 56
5.6
66UK IE3
104 40
66XK IE3 *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

84
KRT

KRT D 100-315 1750 rpm 4 inch


3
D 0 50 m/h 100 150 200 250

0 20 l/s 40 60

80

Qmin 20
60 50
55
60

TDH 50
64
68
η [%] m
55
70
40 60 70.2
70
50
64 68 10
55 64.6
ft 64 64
59.2 60
60 ø222
20
55
55
ø210
50
ø196

0 0
0 200 400 600 US.gpm 800 1000

10
ø222

Power Input
8 6

hp ø210
kW
6
4

ø196
4
0 200 400 600 US.gpm 800 1000
Flow K 43103
Free passage 3” (75 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

54UK IE3
54XK IE3 *) New:
104 40
54U Motor versions UK, XK for wet and dry installation
75
7.5 56
5.6
54X *) with energy-saving motors
74W (Classification: NEMA MG1 “Energy Efficient Motors”).
140 60
74Z *)
74UK IE3
74XK IE3 *)
10 75
7.5 104 40
74U
74X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

85
KRT

KRT D 100-316 1160 rpm 4 inch


3
D 0 100 m/h 200 300

0 20 l/s 40 60 80
75

Qmin 20

60 60
65
70

ft
60
65
75
η [%] m
70 77
TDH
60
40 65 72.8 75

60 68.7
70 10
70
65
65
64.6 ø306
65
60
20 60 ø288
60
ø278
ø270

5
0 200 400 600 800 1000 1200 1400
US.gpm

14
ø306 10

Power Input 10 ø288 kW

hp ø278
5

5 ø270

3
0 200 400 600 800 1000 1200 1400
Flow US.gpm K43117
Free passage 3 3/
8” (85 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1 G, G1
Hp kW oF oC Hp kW oF oC

46U 96U
140 60
46X *) 96X *)
104 40 10 0
10.0 75
7.5
46UK IE3 126W
65
6.5 48
4.8 104 40
46XK IE3 *) 126Z *)
66W 126U
140 60 15 0
15.0 11 2
11.2 140 60
66Z *) 126X *)
66UK IE3
66XK IE3 *) New:
104 40
66UK IE3
75
7.5 56
5.6 Motor versions UK, XK for wet and dry installation
66XK IE3 *)
96W with energy-saving motors
140 60 (Classification: NEMA MG1 “Energy Efficient Motors”).
96Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

86
KRT

KRT D 150-251 1160 rpm 6 inch


3
D 0 100 200 m /h 300 360

0 20 40 l/s 60 80 100
40

10

30 Qmin
50
60
66
70.5
m
TDH

20
50
75
77
η [%]
60 77.4
66 77
70.5 75
5
ft 50
60 73.7 70.5
66 66
70.5
10 70.1 ø254
ø240
66

ø225

2
0 200 400 600 800 1000 1200 1400 1600
US.gpm

kW
ø254
Power Input
6
4
hp

4 ø240

ø225 2

2
0 200 400 600 800 1000 1200 1400 1600
Flow
US.gpm
K43035/1
Free passage 4” (100 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

46U
46X *) New:
104 40
46UK IE3 Motor versions UK, XK for wet and dry installation
65
6.5 48
4.8
46XK IE3 *) with energy-saving motors
66W (Classification: NEMA MG1 “Energy Efficient Motors”).
140 60
66Z *)
66UK IE3
66XK IE3 *)
75
7.5 56
5.6 104 40
96W
96Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

87
KRT

KRT D 150-315 1160 rpm 6 inch


3
D 0 100 200 m /h 300 400 440

0 20 40 60 l/s 80 100 120


75

20
Qmin
60
50
60
ft 66 m
TDH
50
60
70
73 η [%]

66 76
40 70 76.9
50 73
76
60
66
75.5
73
10
70 70
73
71.3
70
70 ø317
66
20 66 ø300

ø280

10
0 200 400 600 800 1000 1200 1400 1600 1800 1950
US.gpm

17

ø317
15 kW

Power Input 10
hp
ø300

10

ø280
6
7
0 200 400 600 800 1000 1200 1400 1600 1800 1950
Flow US.gpm
K43032
Free passage 4” (100 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

96U
104 40
96X *)
10 75
7.5
126W
140 60
126Z *)
126U
15 11 2
11.2 104 40
126X *)
156U
20 14 9
14.9 104 40
156X *)
196W
18 13 4
13.4 140 60
196Z *)
196U
24 17 9
17.9 104 40
196X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

88
KRT

KRT D 150-400 1160 rpm 6 inch


3
D 0 100 m/h 200 300 400

0 20 l/s 40 60 80 100 120


110

100 30
Qmin
50

60
m
80 50 64

TDH 50
60
64
68

70
η [%]
70.3 20
70
60 50 60
67.5
68
ft 64
60 64.2
64
64 64
61.7
40 ø363
60 60 ø352 10
ø338
ø326
20

0 200 400 600 800 1000 1200 1400 1600 1800 2000
US.gpm

30 ø363
20
hp ø352
Power Input

20 ø338 kW

ø326

10

10

0 200 400 600 800 1000 1200 1400 1600 1800 2000
Flow US.gpm K43113
Free passage 4” (100 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

206W
18 13 4
13.4 140 60
206Z *)
206U
24 17 9
17.9 104 40
206X *)
266W
24 17 9
17.9 140 60
266Z *)
266U
32 23 9
23.9 104 40
266X *)
326W
32 23 9
23.9 140 60
326Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

89
KRT

KRT D 150-401 1160 rpm 6 inch


3
D 0 200 m /h 400 600

0 50 l/s 100 150 200


150

40
ft Qmin
60
65
100
60
65
70
72
η [%] m

TDH
60 73.6
70
65
71 72
60

65 70
70 20
68.7

66.8 65
50 65
65 ø412
65 60
60 ø398
60
ø384
ø370

10
0 500 1000 1500 2000 US.gpm 2500 3000

60
ø412
40
hp
Power Input ø398

40 kW
ø384

ø370
20

20

0 500 1000 1500 2000 US.gpm 2500 3000


Flow K43109
Free passage 4 3/8” (110 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

326W
30 22 4
22.4 140 60
326Z *)
326U
104 40
326X *)
40 29 8
29.8
406W
140 60
406Z *)
406U
104 40
406X *)
50 37 3
37.3
506W
140 60
506Z *)
506U
65 48 5
48.5 104 40
506X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

90
KRT

KRT D 200-315 1160 rpm 8 inch


3
D 0 200 400 m /h 600

0 50 100 l/s 150 170


60

Qmin 15
50

60
40
70

TDH
50
60
75
η [%] 10
ft
70 79.6
75 m
50
75
20 60 78.6
70
70 5
75 ø315
73.9 70
70 ø300
ø280

0 0
0 500 1000 1500 2000 2500 2800
US.gpm

20

kW
hp
ø315
Power Input 10

10
ø300

ø280

2
2
0 500 1000 1500 2000 2500 2800
Flow
US.gpm
K43029
Free passage 4” (100 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

96U
104 40
96X *)
10 75
7.5
126W
140 60
126Z *)
126U
15 11 2
11.2 104 40
126X *)
156U
20 14 9
14.9 104 40
156X *)
196W
18 13 4
13.4 140 60
196Z *)
196U
24 17 9
17.9 104 40
196X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

91
KRT

KRT D 200-400 1160 rpm 8 inch


3
D 0 200 m /h 400 600 800 1000

0 100 l/s 200 300


120

100 30
Qmin
60
80 65
60 70

TDH
60
65
70
75
η [%] 20
60 65
75
78
70 78.5
76.5 78
60 m
65
74.3 75
75
40 70
70.3 70
70 70
70 10
ft 65
65
65 65
60 ø402
20 60
ø390
ø375
ø355

0 0
0 1000 2000 3000 US.gpm 4000 5000

55
40

ø402
Power Input 40 kW
ø390

hp ø375
20

20 ø355

0 1000 2000 3000 US.gpm 4000 5000


Flow K43089
Free passage 4” (100 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

326W
30 22 4
22.4 140 60
326Z *)
326U
104 40
326X *)
40 29 8
29.8
406W
140 60
406Z *)
406U
104 40
406X *)
50 37 3
37.3
506W
140 60
506Z *)
506U
65 48 5
48.5 104 40
506X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

92
KRT

KRT D 250-400 1160 rpm 10 inch


3
D 0 200 400 600 m /h 800 1000 1150

0 100 200 l/s 300


80

20
60 Qmin
50

50
60 m
65
TDH 60 70
40 65
70 75
η [%]
50 76
10
ft 60 73.8 75
65
70
50 70
69.1 65
20 60 65 60
64.3 60
65
60 50 ø370
60
50 ø360
ø340
ø320
0 0
0 1000 2000 3000 4000 5000
US.gpm

50

40
kW
Power Input
hp ø370
20
ø360

20
ø340

ø320
5
5
0 1000 2000 3000 4000 5000
Flow
US.gpm
K43027
Free passage 4 3/4” (120 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

326W
30 22 4
22.4 140 60
326Z *)
326U
104 40
326X *)
40 29 8
29.8
406W
140 60
406Z *)
406U
104 40
406X *)
50 37 3
37.3
506W
140 60
506Z *)
506U
65 48 5
48.5 104 40
506X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

93
KRT

KRT D 250-400 875 rpm 10 inch


3
D 0 200 400 m /h 600 800

0 50 100 l/s 150 200 230

40

Qmin 10
30 50

60
50
65 m
TDH

20
60
65
70
η [%]
70
50 74.9
72.8 5
ft 60
65 70
50 70
68.1 65
10 60 65 60
65 60
63.2 50
60 50
60 ø370
50 ø360
50 ø340
ø320

0 0
0 500 1000 1500 2000 2500 3000 3500 3800
US.gpm

20

kW
hp
Power Input 10
ø370

10 ø360

ø340

ø320
2
2
0 500 1000 1500 2000 2500 3000 3500 3800
Flow
US.gpm
K43028
Free passage 4 3/4” (120 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

108U
104 40
108X *)
13 97
9.7
178W
140 60
178Z *)
178U
22 16 4
16.4 104 40
178X *)
218W
20 14 9
14.9 140 60
218Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

94
KRT

KRT D 300-400 875 rpm 12 inch


3
D 0 200 400 600 m /h 800 1000 1100

0 100 l/s 200 300


48

40

60
Qmin 10
30 68
74
TDH
60 78 m
68
74
79.3 η [%]
20 78
60
68 77.7 74 5
ft
68
73.7 74 60
10 68
68
ø408
60
60
ø390
ø375

0 0
0 1000 2000 3000 4000 5000
US.gpm

34

30

20
hp
Power Input

20 kW
ø408

10
ø390
10
ø375
6
0 1000 2000 3000 4000 5000
Flow
US.gpm
K43026
Free passage 6” (150 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1
Hp kW oF oC

108U
104 40
108X *)
13 97
9.7
178W
140 60
178Z *)
178U
22 16 4
16.4 104 40
178X *)
218W
20 14 9
14.9 140 60
218Z *)
218U
104 40
218X *)
25 18 7
18.7
268W
140 60
268Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

95
KRT

Single vane impellers 3”, 4”, 6” & 8”

KRT 80, 100, 150, 200 E--Impeller


with E-Impeller
E
4--pole (1750 rpm)
6--pole (1160 rpm)

20 30 40 50 m3/h 100 200 300 400 500


4 5 l/s 10 20 30 40 50 100 200
300

200
50
40
100 30

80--251/ 4p 20
50 100--251/ 4p 150--401/ 6p
40
10
30
80--251/ 6p 200--401
/6p H
20 [m]
150--315/ 6p
5
4
10 3
TDH
[ft] 2
5
50 Q[US.gpm] 100 200 300 400 500 Flow 1000 2000 3000 4000

0W 382 462--02

96
KRT

KRT E 80-251 1750 rpm 3 inch


E 0 50 m#/h 100 150 200 250

0 20 l/s 40 60
140

Qmin 40
50
120 55
60
65

100
50
55
60
65
70
73
75
η [%]
m
50 70 76.7
55 73
60 75
65
50 75.6 75
TDH 80 55 70
73
60 73 75
65 70
50 74.2 73
55 70 70
20
60 73 ø270
60 65 71
70 70 65
ft 67.6 ø255
65
65
60
40 65
60
55
60 55 ø240
55 50
50 ø225
20 ø210

10
0 200 400 600 800 1000
US.gpm
0 200 IM.gpm 400 600 800
28
20
ø270

20 ø255 kW
Power Input

hp ø240
10
ø225
10
ø210

0 0
0 200 400 600 800 1000
Flow US.gpm
K42592--04
Free passage 3” (76 mm)
MOTOR RATING MAX. MOTOR CODE
MOTOR RATING MAX. MOTOR CODE Material LIQUID TEMP.
TEMP
Material LIQUID TEMP.
TEMP
G
G Hp kW oF oC
Hp kW oF oC
164U
74UK IE3 104 40
164X *)
74XK IE3*) 20 14 9
14.9
104 40 214W
74U 140 60
10 75
7.5 214Z *)
74X *) 194U
114W 25 18 6
18.6 104 40
140 60 194X *)
114Z *) 214U
114U 30 22 3
22.3 104 40
104 40 214X *)
114X *)
15 11 2
11.2
164W
140 60 New:
164Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D Motor versions UK, XK for wet and dry installation
with energy-saving motors
(Classification: NEMA MG1 “Energy Efficient Motors”).

97
KRT

KRT E 80-251 1160 rpm 3 inch


3
E 0 50 100 m /h 150 170

0 10 20 l/s 30 40 46

60
Qmin
50
55
60

50
55
65
70
η [%]
60 73
65
75
40 50
55
70 75.2
75
60 73
TDH 65
50 74.1 73
55
60
70
73 70 10
ft 65 72.7
50 70
55 65
60
69.5 70 ø270
65 65
66.1 65 ø255
20 65
65
60
60 55 m
60 55 50
55 50 ø240
50
ø210 ø225

0 0
0 100 200 300 400 500 600 700 760
US.gpm

8
ø270
kW
6
ø255
Power Input 4
hp
ø240
4
ø225

ø210 2
2

0.5
0 100 200 300 400 500 600 700 760
Flow
US.gpm
K42883/1
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC

46U 96U
104 40
46X *) 96X *)
104 40 10 75
7.5
46UK IE3 126W
65
6.5 48
4.8 140 60
46XK IE3 *) 126Z *)
66W
140 60
66Z *) New:
66U
66X *) Motor versions UK, XK for wet and dry installation
104 40 with energy-saving motors
66UK IE3
75
7.5 56
5.6 (Classification: NEMA MG1 “Energy Efficient Motors”).
66XK IE3 *)
96W
140 60
96Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

98
KRT

KRT E 100-251 1750 rpm 4 inch


3
E 0 50 100 m /h 150 200 250

0 20 40 l/s 60 70
120

Qmin
100 30
53
60
53
60 66

80 53
66 70
70 74
η [%]
60 74
TDH 76.5
53 66 76.8
76.5
60 70 75.8 20
60 66 74
53 71.7 74
60 ø252
ft 69.5 70 m
66 ø245
67.1
53 66 ø236
40 66
54.2 ø220
10
53
ø202

20 ø184

0 200 400 600 800 1000 1150


US.gpm

20 ø252
ø245
kW

Power Input
hp ø236

ø220 10

10 ø202
ø184

2
2
0 200 400 Flow 600 800 1000 1150
Free passage US.gpm
3 1/8” -- 3 3/4” (80 mm -- 95 mm) K42580/1

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC
54UK IE3 114U
104 40
54XK IE3*) 114X *)
104 40 15 11 2
11.2
54U 164W
75
7.5 56
5.6 140 60
54X *) 164Z *)
74W 164U
140 60 104 40
74Z *) 164X *)
20 14 9
14.9
74UK IE3 214W
140 60
74XK IE3*) 214Z *)
104 40
74U 194U
10 75
7.5 25 18 6
18.6 104 40
74X *) 194X *)
114W 214U
140 60 30 22 3
22.3 104 40
114Z *) 214X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

New: Motor versions UK, XK for wet and dry installation with energy-saving motors
(Classification: NEMA MG1 “Energy Efficient Motors”).
99
KRT

KRT E 150-315 1160 rpm 6 inch


3
E 0 100 200 m /h 300 400 440

0 20 40 60 l/s 80 100 120

60

Qmin
55
55
60 15
60 66

η [%]
55 66
60 70
40 55
70
TDH 60 66
72.2
66
70
55 72
60
10
ft 70 70.8
70
66 70.5
70
70 70 m
55 68
66
60 66
20 61 66 66 66
ø305
60
ø295 5
60 ø275
55 ø265
ø254
ø232
5
0 200 400 600 800 1000 1200 1400 1600 1800 2000
US.gpm

15
ø305
10
hp ø295

Power Input
10 ø275 kW
ø265

ø254
5
ø232
5

2
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Flow US.gpm
Free passage 4 1/2”--4 3/4” (110--120 mm) K42076/2

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC

46U 96U
104 40
46X *) 96X *)
104 40 10 75
7.5
46UK IE3 126W
65
6.5 48
4.8 140 60
46XK IE3 *) 126Z *)
66W 126U
140 60 15 11 2
11.2 104 40
66Z *) 126X *)
66U 156U
20 14 9
14.9 104 40
66X *) 156X *)
104 40
66UK IE3 196W
75
7.5 56
5.6 18 13 4
13.4 140 60
66XK IE3 *) 196Z *)
96W 196U
140 60 24 17 9
17.9 104 40
96Z *) 196X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
New: Motor versions UK, XK for wet and dry installation with energy-saving motors
(Classification: NEMA MG1 “Energy Efficient Motors”).
100
KRT

KRT E 150-401 1160 rpm 6 inch


3
E 0 200 400 m /h 600

0 50 100 l/s 150 180


140
40

120
Qmin
55
100 60 m
64
68

TDH
55
60
64
70
73
74
η [%]
80 55 68
55 60 70 74.9
ft 60 64
55 71.7 74
64 68 73 20
60
60 64
68 68.9 70
68 70 68
68 69.9
68 ø407
69.4 68 64 64
68
40 64 60 ø386
64 60 55
60 55 ø384
55
ø370
20
ø348
10
0 500 1000 1500 2000 2500 3000
US.gpm

60

ø407 40
hp

ø386 kW
Power Input 40
ø384

ø370 20

20 ø348

5
0 500 1000 1500 2000 2500 3000
Flow US.gpm
K42581/1
Free passage 4 1/2”--5 1/2” (115--140 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC

206U 406U
104 40 104 40
206X *) 406X *)
24 17 9
17.9 50 37 3
37.3
266W 506W
140 60 140 60
266Z *) 506Z *)
266U 506U
104 40 65 48 5
48.5 104 40
266X *) 506X *)
30 22 4
22.4
326W
140 60
326Z *)
326U
104 40
326X *)
40 29 8
29.8
406W
140 60
406Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

101
KRT

KRT E 200-401 1160 rpm 8 inch


3
E 0 200 400 m /h 600 800 950

0 50 100 150 l/s 200 250


130

120

100
Qmin
55
80
60
TDH 55
60
65
67.5
69
η [%]
20
65 70.5
60 55
67.5 71
60
69
ft 55
65 70.5
67.5
60 70
69 69
m
40 65
69.6 69 ø400
67.5 67.5
69
68 67.5 ø373
67.5 65
65 ø351
20
ø319 5

5
0 500 1000 1500 2000 2500 3000 3500 4000 4200
US.gpm

60
ø400
40
hp

Power Input kW
40 ø373

ø351
20
ø319
20

10
0 500 1000 1500 2000 2500 3000 3500 4000 4200
Flow US.gpm
K42582/1
Free passage 4 3/4”--5 1/2” (121--143 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G G
Hp kW oF oC Hp kW oF oC

266U 606WN
104 40 80 80 0
80.0 104 40
266X *) 606ZN *)
30 22 4
22.4
326W 606UN
140 60 80 80 0
80.0 104 40
326Z *) 606XN *)
326U
104 40
326X *)
40 29 8
29.8
406W
140 60
406Z *)
406U
104 40
406X *)
50 37 3
37.3
506W
140 60
506Z *)
506U
65 48 5
48.5 104 40
506X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
102
KRT

Vortex impellers 11/2”, 3”, 4” & 6”

KRT 40, 80, 100, 150 F--Impeller


with F-Impeller
F
2--pole (3500 rpm)
4--pole (1750 rpm)
6--pole (1160 rpm)

2 3 45 m3/h 10 20 30 40 50 100 200 300400


0.4 l/s 1 2 3 45 10 20 30 40 50 100 200
400
100
300

200 40--250/ 2p 100--401/ 4p


50
80--250/ 2p 40
100 100--316/ 4p 30

80--250/ 4p 20
40--250/ 4p 100--250/ 4p
50
150--401/ 6p
40
10
30
80--250/ 6p
150--315/ 6p H
20 [m]
5
4
10 3
TDH
[ft] 2
5
5 10 20 30 40 50 100 200 300400 Q[US.gpm] 1000 2000 3000
Flow
0W 382 463--03

103
KRT

KRT F 40-250 3500 rpm 11/2 inch


3
F 0 10 m /h 20 30 40 50

0 5 l/s 10 15
270
80
250 10
20
30
η [%]
36
10
40 m
20
30 43
36 44.5
10 40 45.1
20
200 30 43 ø190
60
36 44.5
TDH 40
10 45.1
20 43
ft 30
36 44.5
40 44.5
45 ø180
10 43
20 44.5
150 30
44.5
36 45.2
40 43
43 44.5 ø170 40
44.5
43
45.6 ø160

100 ø150

0 50 100 150 200 250


US.gpm

24
ø190 ø180 16
20
ø170
kW
Power Input ø160
hp
10
ø150
10

2
2
0 50 100 150 200 250
US.gpm
Flow K43006
Free passage 1” (25 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1, G2, GH, H C1, C2


Hp kW Hp kW oF oC

82U
104 40
82X *)
10 75
7.5 10 75
7.5
122W
140 60
122Z *)
122U
15 11 2
11.2 15 11 2
11.2 104 40
122X *)
172W
20 14 9
14.9 20 14 9
14.9 140 60
172Z *)
172U
23 17 2
17.2 22 16 4
16.4 104 40
172X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

104
KRT

KRT F 40-250 1750 rpm 11/2 inch


3
F 0 10 m /h 20 30

0 2 l/s 4 6 8 10
95

10 20
30

η [%]
34
80 38
10 20 40
30
34 42.1
38
40 ø210
10
20
20
60 10
30
34 41.5
TDH 20 38
30 40 ø200
34
10 20 38
ft 30
34 40 41.5 m
10 38 41.2
20 40
30 40
34
38 41.1 40 38
40 10 20 40
30 34 41.2 40 38
38
40 40 38 ø190 10
41.6 34
38
34 ø180
40 34
38 ø170
34 ø160
20 30
ø150

10
0 20 40 60 80 100 120 140 160
US.gpm

5.5 4
ø210
ø200

4 ø190 kW
Power Input ø180
hp ø170
2
ø160
2 ø150

0 0
0 20 40 60 80 100 120 140 160
US.gpm
Flow K43007
Free passage 1” (25 mm)
MOTOR RATING MAX. MOTOR CODE
MOTOR RATING MAX. MOTOR CODE Material LIQUID TEMP.
TEMP
Material LIQUID TEMP.
TEMP
G, G1, G2, GH, H C1, C2
G, G1, G2, GH, H C1, C2 Hp kW Hp kW oF oC
Hp kW Hp kW oF oC
74UK IE3
44UK IE3 74XK IE3 *)
104 40 104 40
44XK IE3 *) 74U
5 37
3.7 5 37
3.7 10 75
7.5 10 75
7.5
54W 74X *)
140 60
54Z *) 114W
54UK IE3 140 60
114Z *)
54XK IE3 *)
104 40
54U
75
7.5 56
5.6 8 56
5.6 New:
54X *)
140 60
74W Motor versions UK, XK for wet and dry installation
74Z *) with energy-saving motors
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D (Classification: NEMA MG1 “Energy Efficient Motors”).

105
KRT

KRT F 80-250 3500 rpm 3 inch


F 0 50 m#/h 100 150

0 10 l/s 20 30 40 50
230

20
30
200 Qmax 60
40
20
30

40
44
46 η [%]
m
20
44 46.9
30
150
TDH 40 45.4 46
20
30
44 44 44
40
ft 44.3
40 44
40 40
42.9
100
40
ø180
40
ø170

ø160 20
30
ø150
50

0 100 200 300 400 500 600 700 800


US.gpm
0 200 IM.gpm 400 600
50
ø180 35
ø170
40
kW
Power Input ø160
hp
ø150 20

20

5
5
0 100 200 300 400 500 600 700 800
US.gpm K43193--00
Flow
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, G2, GH, H C1, C2 G, G1, G2, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

122W 222U
10 75
7.5 10 75
7.5 140 60 30 22 -- -- 104 40
122Z *) 222X *)
122U 252U
15 11 2
11.2 15 11 2
11.2 104 40 34 25 3
25.3 30 22 4
22.4 104 40
122X *) 252X *)
172W
20 14 9
14.9 20 14 9
14.9 140 60
172Z *)
172U
23 17 2
17.2 22 16 4
16.4 104 40
172X *)
252W
25 18 7
18.7 24 17 9
17.9 140 60
252Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

106
KRT

KRT F 80-250 1750 rpm 3 inch


F 0 50 m#/h 100 150 200 250

0 20 l/s 40 60 80
150
Qmin
20
40
40
20 50
40
50
54
56 η [%]
20
100 20 40
54
58 Qmax
40 50
56 58.3 m
58
20 50 54
57.3
TDH 40 54 56
56 54
ft 20 50 56 56
56.1 54
40 54 56
50 20
20 50 54
54.9 54 50
40
53.3
50 54 50
50 50 ø265
52.5
50 50 ø260
50
ø250
40
ø249
40 40
ø237
ø210
ø190

0 0
0 200 400 600 800 1000 1200
US.gpm
0 200 IM.gpm 400 600 800 1000
40

ø265

hp
ø260
20
Power Input
ø250
20
ø249

ø237 kW
ø210
ø190

0 0
0 200 400 600 800 1000 1200
Flow
US.gpm
Free passage 3” (76 mm) K43060--02

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, G2, GH, H C1, C2 G, G1, G2, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

54UK IE3 114U


-- -- 104 40
54XK IE3 *) 114X *)
104 40 15 11 2
11.2 15 11 2
11.2
54U 164W
75
7.5 56
5.6 140 60
54X *) 164Z *)
75
7.5 56
5.6
74W 164U
140 60 104 40
74Z *) 164X *)
20 14 9
14.9 20 14 9
14.9
74UK IE3 214W
-- -- 140 60
74XK IE3 *) 214Z *)
104 40
74U 194U
10 75
7.5 25 18 6
18.6 -- -- 104 40
74X *) 194X *)
10 75
7.5
114W 214U
140 60 30 22 3
22.3 25 18 6
18.6 104 40
114Z *) 214X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
New: Motor versions UK, XK for wet and dry installation with energy-saving motors
(Classification: NEMA MG1 “Energy Efficient Motors”).
107
KRT

KRT F 80-250 1160 rpm 3 inch


3
F 0 50 m /h 100 150

0 10 l/s 20 30 40 50
60
20
30
40
20 50
30
40
η [%] 15
54
20 50
30 56
40 54
20 56.9
30 50
40 40
50 56
20 55.9
30 54
40 54
TDH 54 10
54.6 54
20 30 50
ft 40
54.7 54 50
54 50 ø265
20 30 50 53.5
40 50 m
52 50
50
20 51.1 50 50 ø260
50
ø250 5
40 ø249
40 40

30 ø237
30
20 ø210
ø190
0 0
0 100 200 300 400 500 600 700 800
US.gpm

10 ø265

ø260
hp
Power Input
ø250 5

5 ø249

ø237 kW
ø210
ø190

0 0
0 100 200 300 400 500 600 700 800
US.gpm
Flow K43063
Free passage 3” (76 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, G2, GH, H C1, C2 G, G1, G2, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

46U 96U
65
6.5 48
4.8 104 40 104 40
46X *) 96X *)
10 75
7.5 10 75
7.5
46UK IE3 126W
65
6.5 48
4.8 -- -- 104 40 140 60
46XK IE3 *) 126Z *)
66W
60
6.0 45
4.5 140 60
66Z *) New:
46UK IE3
-- -- 104 40 Motor versions UK, XK for wet and dry installation
46XK IE3 *)
75
7.5 56
5.6 with energy-saving motors
96W
75
7.5 56
5.6 140 60 (Classification: NEMA MG1 “Energy Efficient Motors”).
96Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

108
KRT

KRT F 100-250 1750 rpm 4 inch


F 0 50 m#/h 100 150 200 250

0 20 l/s 40 60

120 10 20
30
38
45
10 20
30 49
100 38 52
Qmax 30
10
20
45
49
52
54.5
η [%]
30
38 56.5
m
80 45
49 54.1
TDH 52
10
ø265
20 53.2 20
30 52
60 38
45 52 49
ft 49
10 49 ø260
20 50.7
30
40 38 49 45
10
20 45
45.6 45 ø249 10
30 45
38
39.3 38 ø215
20 38
ø185
ø166

5
0 200 400 600 800 1000
US.gpm
0 200 IM.gpm 400 600 800
40

ø265
hp
Power Input ø260 20

20
ø249

kW
ø215
ø185
ø166

0 0
0 200 400 600 800 1000
Flow US.gpm
Free passage 4” (100 mm) K42071--04

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, G2, GH, H C1, C2 G, G1, G2, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

54UK IE3 114U


-- -- 104 40
54XK IE3 *) 114X *)
104 40 15 11 2
11.2 15 11 2
11.2
54U 164W
75
7.5 56
5.6 140 60
54X *) 164Z *)
75
7.5 56
5.6
74W 164U
140 60 104 40
74Z *) 164X *)
20 14 9
14.9 20 14 9
14.9
74UK IE3 214W
-- -- 140 60
74XK IE3 *) 214Z *)
104 40
74U 194U
10 75
7.5 25 18 6
18.6 -- -- 104 40
74X *) 194X *)
10 75
7.5
114W 214U
140 60 30 22 3
22.3 25 18 6
18.6 104 40
114Z *) 214X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D
New: Motor versions UK, XK for wet and dry installation with energy-saving motors
(Classification: NEMA MG1 “Energy Efficient Motors”).
109
KRT

KRT F 100-316 1750 rpm 4 inch


3
F 0 50 100 m /h 150 200 230

0 20 40 l/s 60
170

160 20
30
40
46
20 50
140
20
30

30
40
46
53.4
ø290 η [%] 40
40 50
20 46 53.5
30 50
120 40
56
57
46 53.5 57.7
50 56 ø279
TDH 53.5 57
20 58
30 56
40 57 58.7
100 20 46 m
30 50 ø275
40 53.5 58
ft 46
50 56
53.5 58.3
56 57
80 57 57.6 ø261
57.6
57
56
57
56 20
60 53.5 ø250
50
ø236

40
0 200 400 600 800 1000
US.gpm

40

ø290 ø279 ø275


ø261

hp kW
Power Input 20
ø250
ø236

20

5
5
0 200 400 600 800 1000
US.gpm
Flow K42593
Free passage 4” (100 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G, G1, G2, GH, H C1, C2


Hp kW Hp kW oF oC

114U
104 40
114X *)
15 11 2
11.2 15 11 2
11.2
164W
140 60
164Z *)
164U
20 14 9
14.9 20 14 9
14.9 104 40
164X *)
294W
31 23 1
23.1 28 20 9
20.9 140 60
294Z *)
294U
36 26 8
26.8 34 25 4
25.4 104 40
294X *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

110
KRT

KRT F 100-401 1750 rpm 4 inch


3
F 0 50 100 m /h 150 200 230

0 20 40 l/s 60
270
80
10
250 20
30
36
η [%]
40
10
20 44
30 46.5 47.3
10 36
20 40 ø390
30 44
10 36 46.5
200 20 40 48.4
30 44 ø370 60
10 36 46.5
20 40 49
TDH 30 44 49.7
36 46.5
ft 40 49 ø355
44 50
46.5 51
10
49 50 ø340 m
20
30 51.5
36
150 40
44 ø325
46.5
49 50
52
10 20
52.6 40
30
36 40 ø300
44 46.5
49
50
50.4
100
ø270

80
0 200 400 600 800 1000
US.gpm

100
ø390
ø370
kW
hp ø355
ø340
Power Input ø325 50
ø300
50
ø270

10
10
0 200 400 600 800 1000
Free passage 4” (100 mm) Flow US.gpm
K42588

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, G2, GH, H C1, C2 G, G1, G2, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

234U 654U
28 20 9
20.9 -- -- 104 40 83 61 9
61.9 74 55 2
55.2 104 40
234X *) 654X *)
294W 804WN
31 23 1
23.1 -- -- 140 60 100 74 6
74.6 75 56 140 60
294Z *) 804ZN *)
294U 804UN
36 26 8
26.8 -- -- 104 40 107 79 8
79.8 90 67 104 40
294X *)
354W 804XN *)
45 33 6
33.6 37 27 6
27.6 140 60 954WN
354X *) 121 90 2
90.2 95 71 140 60
354U 954ZN *)
104 40 954UN
354X *) 127 94 7
94.7 100 75 104 40
50 37 45 34
504W 954XN *)
140 60
504Z *) 1104WN
504U -- -- 115 86 140 60
104 40 1104ZN *)
65 48 5
48.5 56 41 8
41.8 504X *)
654W
140 60
654Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

111
KRT

KRT F 150-315 1160 rpm 6 inch


3
F 0 100 200 m /h 300 400 480

0 20 40 60 l/s 80 100 120 135

60 20 30 36
41
46
50
20
30 36
41
51.5
53
η [%]
46
50 53.6
51.5
20 53
40 30
36 52
41
51.5
TDH 46 51.5
50
50
10
ft 20 48.6
30
36 46
46
20 41 46
30 ø290
36 41.9
20 41 41
39.7 41 ø279 m
36
36 ø261
30 ø236
ø216

0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2150
US.gpm

28
20
ø290

20 kW
Power Input ø279

hp
ø261 10

10
ø236
ø216

2
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2150
Flow
US.gpm K42072/1
Free passage 4 3/4” (120 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, G2, GH, H C1, C2 G, G1, G2, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

46U 126U
104 40 15 11 2
11.2 104 40
46X *) 126X *)
65
6.5 48
4.8 65
6.5 48
4.8 15 11 2
11.2
66W 206W
140 60 18 13 4
13.4 140 60
66Z *) 206Z *)
66U 206U
104 40 22 16 4
16.4 104 40
66X *) 206X *)
75
7.5 56
5.6 75
7.5 56
5.6 24 17 9
17.9
96W 266W
140 60 20 14 9
14.9 140 60
96Z *) 266Z *)
96U 266U
104 40 30 22 4
22.4 27 20 1
20.1 104 40
96X *) 266X *)
10 75
7.5 10 75
7.5
126W
140 60
126Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

112
KRT

KRT F 150-401 1160 rpm 6 inch


3
F 0 200 400 m /h 600

0 50 100 l/s 150 170

100 30
20
32
39
43
45.5
20
80 32
39
43
49.5

51.5
η [%]
20 45.5
32 51.9
39 49.5
43 51.5 20
TDH 45.5 50.1
60 20
32
39 48.8 49.5 49.5
ft 43 m
20 ø390
32 45.5
39 46
40 45.5 45.5 ø360
43
43.4 43
43 ø330 10
39
39 ø300

20 ø270

10
0 500 1000 1500 2000 2500 2800
US.gpm

75
ø390
60
ø360 40
hp
Power Input
ø330
40 kW
ø300

ø270 20
20

0 0
0 500 1000 1500 2000 2500 2800
Flow
US.gpm
K42587
Free passage 5 5/16” (135 mm)

MOTOR RATING MAX. MOTOR CODE MOTOR RATING MAX. MOTOR CODE
Material LIQUID TEMP.
TEMP Material LIQUID TEMP.
TEMP

G, G1, G2, GH, H C1, C2 G, G1, G2, GH, H C1, C2


Hp kW Hp kW oF oC Hp kW Hp kW oF oC

206U 406U
104 40 104 40
206X *) 406X *)
24 17 9
17.9 -- -- 50 37 3
37.3 48 35 8
35.8
266W 506W
140 60 140 60
266Z *) 506Z *)
266U 506U
-- -- 104 40 65 48 5
48.5 56 41 8
41.8 104 40
266X *) 506X *)
30 22 4
22.4
326W 606WN
30 22 4
22.4 140 60 -- -- 60 44 7
44.7 140 60
326Z *) 606ZN *)
326U 606UN
104 40 80 80 70 52 2
52.2 104 40
326X *) 606XN *)
40 29 8
29.8 36 26 8
26.8
406W
140 60
406Z *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

113
KRT

Grinder

KRT 40 S--Impeller
with S-Impeller
S
2--pole (3500 rpm)

2 m3/h 3 4 5 10 20 30 40
0.4 0.5 1 l/s 2 3 4 5 10
400
100
300

200 40--250 /2p


50
40
100 30

20
50
40
10
30
H
20 [m]
5
4
10 3
TDH
[ft] 2
5
5 Q[US.gpm] 10 20 30 40 50 100 200
Flow

0W 382 460--02

114
KRT

KRT S 40-250 3500 rpm 1 1/2 inch


3
S 0 10 m /h 20 30

0 2 4 l/s 6 8
360

100

300
10
20
25
η [%]
30
33.7
10
20 ø225
25
30 m
35
10
20 36.6
25
30
200 35 35
TDH
38.8 ø205
10 50
20 25
ft 30 35 40
35
45
46.4 ø190
10 20 25 45
30 35 40 45 40
50
100 50.7 50 35
45 30
40
35 ø170
30
25
ø150

0 0
0 20 40 60 80 100 120 135
US.gpm

20 ø225

ø205 kW
hp
Power Input
ø190 10

10
ø170

ø150

0 0
0 20 40 60 80 100 120 135
Flow
US.gpm
K42504/3
Free passage 9/
32” (7 mm)

MOTOR RATING MAX. MOTOR CODE


Material LIQUID TEMP.
TEMP

G
Hp kW oF oC

62UG
104 40
62XG *)
75
7.5 56
5.6
82WG
140 60
82ZG *)
82UG
104 40
82XG *)
10 75
7.5
122WG
140 60
122ZG *)
122UG
15 11 2
11.2 104 40
122XG *)
172WG
20 14 9
14.9 104 40
172ZG *)
*) FM/CSA = Explosionproof to Class I, Division 1, Groups C & D

115
KRT

Subject to modification without notice


08.2010
2553.523/12--14

KSB, Inc.
4415 Sarellen Road . Richmond, VA23231
Phone: (804) 222--1818 . Fax: (804) 226--6961 . www.ksbusa.com
KSB Pumps Inc
5885 Kennedy Road . Mississauga . Ontario L4Z 2G3
Phone: (905) 568--9200 . Fax: (905) 568--3740 . www.ksb.ca

You might also like