Type Super-heterodyne, Single down conversion
Noise Figure 2 dB maximum
Linear Range ≥ 100 dB for a 2 µs pulse
Minimum Detectable Signal ≥ -114 dBm for a 2 µs pulse
IF Digitizer 16-Bit
Doppler Signal Processor
Type 3 Multi-channel digital receiver
16-bit per polarization
IF Frequency 60MHz
Maximum Range Bins Up to 4000 per channel
Minimum Range Resolution 25 m
Processing Modes Pulse Pair (PP) or Discrete Fourier Transform
(DFT/FFT)
Clutter Filters Time Domain IIR Filtering, Frequency Domain
Adaptive Filtering with > 55 dB clutter rejection Antenna designs can be customized
for a wide range of applications. Dual-
Antenna
Polarization available, depending on
Type Parabolic, prime focused reflector with scalar feed
Diameter 4.3 m
the user’s preference.
Gain 44 dB min, 45 dB nom
Beam-width ≤ 1.00
Side-lobes 27 dB typ
Cross-Polarization Isolation 30 dB minimum
Polarization Single: Horizontal; Dual: STAR, H-Only
Pedestal
Pedestal Type Elevation over Azimuth
Azimuth Movement 360° continuous
Elevation Movement -5° to +185° with adjustable limits
Positional Accuracy ≤ 0.1°
Scanning Rates Programmable 0 to 6 rpm
Radome
Construction Fiberglass Sandwich or Membrane
Diameter 5.5 m
Transmission Loss, Dry ≤ 0.3 dB
Condition, One-way
Increase of the first side ≤ 1 dB
lobe peak due to radome
Attenuation difference ≤ 0.2 dB
between H & V polarizations
for all azimuths & elevations
Bore-sight change due ≤ 0.1°
to the radome
Geometry Faceted, truncated sphere
Calibration
System dBZ 0 ≤ 1 dB
determination accuracy
System Z DR bias ≤ 0.1 dB (In Dual Polarization (STAR) Configuration)
determination accuracy Baron offers numerous tower
System PHI DP ≤ 1° (In Dual Polarization (STAR) Configuration) options for tower height and design,
determination accuracy in addition to installation on existing
System LDR bias ≤ 0.1 dB (In Dual Polarization (H-Only) Configuration)
determination accuracy
tower structures.
Meteorological Data
Single Polarimetric Mode T, Z, V, W
Dual Polarimetric Mode T, Z, V, W, ZDR, PHIDP, RHOHV, KDP, LDRH