| 4 DLE OPERATING PRESSURE NOTED FOR 150 F SELES Technical Data Burst Pressure vs. Temperature for Safeline’s 2" Kynar (PVDF) Metal Detec- tion Tube. All Safeline Metal Detection Tubes are made of high quality Kynar. This tubing represents a mating of U.S.D.A. and F.D.A. Approved steam cleanable polymer. For use with system temperatures from -40° up to 240°F. st 115 NOTES: baa Burst pressure based on tensile strength: BLP. =(2)(T.S.)(WALL) 0.0. y To calculate working pressure divide burst pressure by a safety factor of 3. 3 2 ‘Temperatures for PVDF are rated between -40° and 240° F BURST PRESSURE X 100 (psi) s Pressure for tubing only. Connections and ends must be | calculated separately ci a ERE GRE EE ET) TEMPERATURE °F In actual testing all results were comparable to the above chart. All pressures were held for a period of time. Upon request, we will have a rating and test result accompany your individual order.