Scale factor in Staad pro for response spectrum analysis


 

   www.sefindia.org Forum Index -> SEFI General Discussion

View previous topic :: View next topic  

Author Message

aditya Posted: Thu Jul 08, 2010 9:50 am    Post subject: Scale factor in Staad pro for response spectrum analysis
...
Dear All,
I am a bit confused about the factor f4 called scale factor in Staad.pro while using the response factor analysis
Joined: 05 Apr 2008
Posts: 151 command. the syntax of the command is:

SPECTRUM SRSS 1893 X 0.036 ACC SCALE 1

My query is: when one wants to do response spectrum analysis, should the value of SCALE be 1 or 9.81?
Since the response spectrum curve given in IS 1983:2002 is plotted with Sa/g (i.e. normalized) on the vertical axis,
should not we take SCALE (f4) =9.81 ? Later on, the scale can be changed depending upon the value of base
shear obtained through seismic coefficient method.
with regards,
aditya

Back to top  
aditya Posted: Sun Jul 11, 2010 4:09 pm    Post subject:
...
Dear Sefians,
I searched in the forum regarding the value of scale factor but found that the discussions are confusing. Some
Joined: 05 Apr 2008
Posts: 151 says "1" and some saying "9.81" while using IS 1893:2002. Please clarify.
Bentley discussion forum says to use "9.81" when the spectrum is given in Sa/g.
with regards,
aditya

Back to top  

Display posts from previous: All Posts   Oldest First   Go

All times are GMT


   www.sefindia.org Forum Index -> SEFI General Discussion

Page 1 of 1

Jump to:  SEFI General Discussion   Go


Translate topic   Go
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
  You cannot vote in polls in this forum
You cannot attach files in this forum
You can download files in this forum

© 2003, 2008 SEFINDIA, Indian Domain Registration

Publishing or acceptance of an advertisement is neither a guarantee nor endorsement of the advertiser's product or service. advertisement policy
Publishing or acceptance of an advertisement is neither a guarantee nor endorsement of the advertiser's product or service. advertisement policy

Structural Engineering Forum of India


75,174 likes

Like Page Donate

Be the first of your friends to like this

You might also like