COURSE

Power & Controls


THYRISTRISED
POWER CONTROLLER

FROM MEDIUM
TO HIGHER ENERGY
CAPACITY CONSERVATION
FOR +
SINGLE/THREE BETTER
PHASE LOAD RESULTS
For the electrical heating system to control the SYSTEM INTEGRATION
temperature at the set point by switching contactors has
many disadvantages, such as wear and tear, limited life of
contractor, noisy operation. Besides these it has limited
accuracy due to limitation of speed of operation, hence
loss of power. All above mentioned disadvantages are
eliminated by COURSE POWER & CONTROLS
THYRISTOR CONTROLLER.
There are two methods by which temperature of
a system is kept close to set point.
1. By switching the power on and off with variable duty
cycle.
2. Phase angle control. Only required power is
delivered to the load.
To suit these, Model CORS-PH-'X' and Model CORS-
TP-'X' are develoed.

MODEL X TP-XT-S1

This model is designed to control the average power. For


this purpose back to back thyristor combination is used.
At zero voltage of sine wave, thyristors are triggered, To facilitate the client's requirement we offer control panel
letting complete cycle to pass through load. By controlling equiped with Meters, Isolators, MCCB, Contactors,
on/off time, average power control is achieved. Changeover switches etc. Also other logic controls and
interfacing with other co-related systems are made on
'X' = 1,2,3, For single, two and three phase operation. request.

MODEL X PH-XT-S1 GENERAL SPECIFICATION

This model is designed to control the power by delivering Input : Single/Two/Three phase AC50 Hz.
the required power to the load. In this method turn 'ON' Output : 0-95% of rated input.(lockable 50-100%)
time of thyristors is delayed in the sine wave. Control Signal : Local-Multiturn potentio-meter.
Thereby only part of the both cycles are passed to the Remote-4-20 mA/0-10V DC.
load. Constant current and constant power control are Ambient Temperature: 45°C Max.
optional features.
'X'= 1,2,3, For single, two and three phase operation. ORDERING INFORMATION

APPLICATIONS 1. Capacity in Kw
2. Operating Voltage
l All types of Electrical Heating Systems. 3. Single/Two/Three Phase System
l Infrared Ovens. 4. Nature of load
l Vaccum Brazing Furnace. 5. Load-Mains or Transformer driven
l Continuous Annealing / Bell Furnace. 6. Input signal
7. Protection/ Indication and other logic requirements.
SALIENT FEATURES
STANDARD CAPACITIES
l Sturdy and Rugged Design.
l Facility of Local and Remote Operation. SINGLE PHASE
l Good accuracy over full range. 3 KW - 6 KW
l Better external noise immunity. 7 KW - 10 KW

THREE PHASE
STANDARD PROTECTIONS
12 KW - 20 KW
25 KW - 36 KW
BUILT-IN
45 KW - 55 KW
l Adjustable over current limit.
60 KW - 80 KW
l dv / dt protection by RC snubber.
120 KW - 150 KW
EXTERNAL
200 KW
l Semiconductor fuse links.
l di / dt protection by Inductance. For Non standard requirements contact Manufacturer.

Manufactured by:
COURSE POWER & CONTROLS
Flat No. 1-B, Rachana Avenue, F.C. Road,
D.G., Pune 411004. TeleFax: 020-25532547.
E-mail: coursepower@gmail.com