ELECTRIC ELEVATORS
PART - 1 GENERAL
1.03 STANDARDS:
Unless otherwise approved, applicable standards are as follows, in order of priority:
A. EN81 and BS5655: parts 1 to 12 – safety rules for the construction and installation of
electric lifts.
B. ANSI/ASME A17.1 - Safety Code for Elevators and Escalators.
1.09 SUBMITTALS
A. Submit under provisions of Division.1
B. Shop Drawings: Indicate the following information:
1. Car, counterweight, sheaves, machine and sheave beams, guide rails, buffers,
ropes, and other components in hoistway.
2. Rail bracket spacing, maximum loads imposed on guide rails requiring load
transfer to building structural framing.
3. Individual weight of principal components, load reaction at points of support.
4. Loads on hoisting beams and location of trolley beams
5. Clearances and over travel of car and counter weight
6. Location of components.
7. Locations in hoistway of traveling cables and connections for car light and
telephone
8. Location and sizes of access doors, doors, and frames
9. Expected heat dissipation of elevator equipment.
10. Interface with building management system.
11. Electrical characteristics and connection requirements.
12. Show arrangement of equipment so rotating elements, sheaves, and other
Ministry of Commerce & Industry 14215-3
Prototype Branch in the Kingdom Cities
equipment can be removed for repairs or replaced without disturbing other
components. Arrange equipment for clear passage through access door.
13. Complete power and control wiring diagrams.
C. Product Data:Provide data on the following, items:
1. Signal and operating fixtures, operating panels indicators.
2. Cab design,dimensions, layout, and components.
3. Cab and hoistway door and frame details.
4. Electrical characteristics and connection requirements.
D. Samples: Submit Samples, illustrating cab floor material, cab interior finishes, cab and
hoistway door and frame finishes.
1.12 QUALIFICATIONS
A. Manufacturer: Company specializing in manufacturing the Products specified in this
section with minimum ten years documented experience.
B. Installer: local Company specializing in performing the work of this section approved
by elevator equipment manufacturer with minimum five years documented experience,
fully qualified staff should be presented for Owner approval.
1.16 WARRANTY
A. Provide Five year manufacture's warranty under provisions of Division.1
B. Warranty: Include coverage for elevator operating equipment and devices.
C. Obtain Lioyd's Inspection Certificate and submit to Owner.
2.01 MANUFACTURERS
The following Manufacturers shall be referred to as a standard for quality, performance
and maintenance reference:
A. Schindler
B. Tayssen.
C. Mitsubishi - Japan
D. Otis - U.S.A
2.02 MATERIALS
A. Rolled Steel Sections, Shapes, Rods: ASTM A36
B. Sheet Steel: ASTM A366 Class (1) with matte finish. ASTM A446 Grade (B) zinc
coated to (G90)
C. Stainless Steel: ASTM A167 Type (304) No. (4) finish.
D. Aluminum: ASTM B221, extruded.
E. Plywood: APA Structural I, Grade (C-D) sanded.
F. Plastic Laminate: NEMA LD3, type, color/pattern and matte surface finish.
Main data
Travel 4.15 m
Mechanical components
Car
Car measurements
1700 mm width x 1550 mm depth x 2300 mm height
The KONE Mix & Match Design Collection offers you the
greatest possible structural freedom to adapt the optical
Construction appearance of your lift to the building according you your
Car Interior: needs. The fitting out of the cabin can be freely chosen from
the material type group offered and either from Standard or
Premium material offering.
KDS300 ST4
Operating and signal elements, Car Round
1 - Yes
Door open with extended door time, button
Narrow Frame
Landing door ST4 - Silver Brushed St. St. AISI304
2 hours fire rated doors
E-Expander bolt
Sill type N1 - Sill w/o carpet trim, in the well
Landing door sill Extruded aluminium profile
Landing Doors
Floor Floor
Finish Fire Class
Number Marking
Alarm bell, at main floor Elevator announcer, not programmable All (CRB_C + CRB_L) Disturbance
alarm, general, potential free Emergency battery drive, monospace or minispace elevator, automatic
Emergency stop switch in shaft, two switches Fire detection, whole building, doors open Acoustic device
for arrival, on car, electronic, twice for down Emergency intercom car - machine room - control room
Elevator link, alarm, mode signals, position binary Lock with Emergency Opening Device OSS LC - Out
of service switch at landing, doors closed, lights off Parking at pre-defined floor, doors closed
TYP_FILTER_THD : L
Control system
Full Collective
Control system principle
Simplex.
Topmost floor
The operating elements for maintenance of the lift and for
possible emergency release are fitted in the maintenance
access panel at the top stop. As the operating elements are
locked away, they can only be activated by authorised
personnel.
Maintenance access panel Access to the operating elements must be guaranteed at all
times during the lift's operating periods. The maintenance
access panel is fitted directly to the shaft door floor frame.
The surface of the maintenance and emergency release
panel is specified in zinc-coated sheet steel, prepared for
final painting on site.
MAP on Landing wall with recess ST4
Equipment Name:
Building Type C&D
Main data
Travel 4.15 m
Shaft
Car
Car measurements
1700 mm width x 1550 mm depth x 2300 mm height
The KONE Mix & Match Design Collection offers you the
greatest possible structural freedom to adapt the optical
Construction appearance of your lift to the building according you your
Car Interior: needs. The fitting out of the cabin can be freely chosen from
the material type group offered and either from Standard or
Premium material offering.
KDS300 ST4
Operating and signal elements, Car Round
1 - Yes
Door open with extended door time, button
Doors
Landing Doors
Floor Floor
Finish Fire Class
Number Marking
Alarm bell, at main floor Elevator announcer, not programmable All (CRB_C + CRB_L) Disturbance
alarm, general, potential free Emergency battery drive, monospace or minispace elevator, automatic
Emergency stop switch in shaft, two switches Fire detection, whole building, doors open Acoustic device
for arrival, on car, electronic, twice for down Emergency intercom car - machine room - control room
Elevator link, alarm, mode signals, position binary Lock with Emergency Opening Device OSS LC - Out
of service switch at landing, doors closed, lights off Parking at pre-defined floor, doors closed
TYP_FILTER_THD : L
Machinery
Control system
Full Collective
Control system principle
Simplex.
Topmost floor
The operating elements for maintenance of the lift and for
possible emergency release are fitted in the maintenance
access panel at the top stop. As the operating elements are
locked away, they can only be activated by authorised
personnel.
Maintenance access panel Access to the operating elements must be guaranteed at all
times during the lift's operating periods. The maintenance
access panel is fitted directly to the shaft door floor frame.
The surface of the maintenance and emergency release
panel is specified in zinc-coated sheet steel, prepared for
final painting on site.
MAP on Landing wall with recess ST4
PART - 3 EXECUTION
3.01 EXAMINATION
A. Verify that hoistway, pit, and machine room are ready for work of this section.
B. Verify hoistway shaft and openings are of correct size and within tolerance.
C. Verify location and size of machine foundation and position of machine foundation
bolts.
D. Verify that electrical power is available and of the correct characteristics.
3.02 PREPARATION
A. Arrange for temporary electrical power for installation work and testing of elevator
components.
3.03 INSTALLATION
A. Install in accordance with ANSI/ASME A17.1.
B. Install system components. Connect equipment to building Utilities.
3.04 TOLERANCES
A. Guide Rail Alignment:
Plumb and parallel to each other 3 mm in accordance with ANSI/ASME A17.1 and
ANSI/ASME A17.2.
B. Cab Movement on Aligned guide Rails:
Smooth movement, with no objectionable lateral or oscillating movement or vibration.
3.07 ADJUSTING
A. Adjust for smooth acceleration and deceleration of car so not to cause passenger
discomfort.
B. Adjust automatic floor leveling feature at each floor to achieve 6 mm from flush.
3.08 CLEANING
A. Clean work under provisions of Division. 1.
B. Remove protective coverings from finished surfaces.
C. Clean surfaces and components ready for inspection.
END OF SECTION