Professional Documents
Culture Documents
Tube Probe Selection Olympus
Tube Probe Selection Olympus
0
MultiScan MS5800 tube inspection: Internal probes
Welcome to the Tube Probe Selection Guide program... Version 3.0!
This tool is intended to assist our distinguished customers and representatives with the probe selection process. This guide recommends standard probes exclusively. If
no probe recommendation is provided, your specifications may require a custom probe design. If so, please contact us for feasibility and evaluation.
The information contained in this guide was carefully revised in compliance with the latest "Probe and Accessories" catalog.
We invite you to download this catalog at the following
http://www.olympus-ims.com/en/tube-inspection-probes/
address:
This guide is best viewed with a screen resolution of 1600 X 900. However, the zoom can be used for a quick fit-to-screen adjustment.
Faster is Better - Generally Available for Immediate Delivery!
The main new features included in the 3.0 version are based on recommendations from our most valuable customers. Because short delivery times are very important
to most of our customers, the 3.0 selection guide now recommends probes that are available off the shelf. Use the probe parameters to locate regularly stocked
probes.
We invite you to browse each page of this guide and to select ECT, RFT, NFT, MFL, and IRIS probes by clicking on the various tabs at the bottom of your screen. For
details, see the page summaries below:
ECT, RFT, NFT, & MFL: This page recommends the best suitable electromagnetic technology probe from a large selection of probe models tailored to your needs,
based on your tube dimensions and material.
MULTIPLE ENTRY: Use this form to generate multiple ECT, RFT, NFT, and MFL probe lists from a selection of tubes.
PROBE FINDER: Enter the required probe specifications: part number and description will automatically populate if the probe is available. Regularly stocked probes
are also displayed with their corresponding U8 ordering number.
ECT F90: This frequency calculation tool is used to calculate the optimal frequency (called "F90") based on material properties such as resistivity, conductivity, and
magnetic permeability.
IRIS: This page provides recommendations for probe components needed to perform IRIS inspections. However, an IRIS system is not complete without accessories
such as pumps, filters, units, cables, etc. See the catalog for more information.
Tools: This page provides tools to help you calculate tube dimensions and convert units.
Please feel free to contact us at any time for assistance with your application. We hope you enjoy this guide!
http://www.olympus-ims.com
Version 3.0 - Released November 11th, 2011
Selection tool for ECT, RFT, NFT, & MFL probes
MultiScan MS5800 tube inspection: Internal probes
##
2 Select the tube material Aluminum brass - SB111 Choix Fill factor
(Used to calculate probe center frequency. If you do not see the material in the list, please consult the "ECT F90" page.) ##
3 Confirm the probe series TEA - ECT Bobbin probe, attached Matériel sélectio
4 Select the cable type and length N - Standard Nylon 20 m (65 ft.)
(Fixed models only) Probe series
##
2 TEA
ECT Bobbin probe, 11.8 mm (0.465 in.), 15 kHz center frequency, 20-m
TEA-118-015-N20 (65.6 ft.) cable.
TED
►►► Faster is Better - Generally Available for Immediate Delivery - U8280510 TEE
TEF
TEG
Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.
1 Enter the TUBE parameters 2 Select the 3 Read or copy the automatic probe INFORMATION
PROBE data
Wall Missin Force a Fill
No OD / Thicknes OD Real Fill Probe Part
Units Value Thicknes g fill Factor Material Model Cable Probe Description Comment/Stock probe
. ID
s
s finned?
ID/OD factor? (%)
factor Number
OD is Real Fill
specify ECT Bobbin probe, 24 mm (0.945 in.), 15
1 inches ID 1.00
->
0.040 Yes 1.08 No 88% Factor is Brass (70/30 Cu-ZN) TEA N20 TEA-240-015-N20 kHz center frequency, 20 m (65.6 ft.) cable.
Know fin material - please contact specialist.
inches 89%
ID is Real Fill
specify RFT Single Exciter probe, 19 mm (0.748 in.), 300
3 mm OD 27.00
->
2.600 21.8 Yes 80% Factor is Carbon steel - A178, A179, A192, A210, A214 TRS N20 TRS-190-300-N20 Hz center frequency, 20 m (65.6 ft.) cable.
NORMALLY AVAILABLE FOR IMMEDIATE DELIVERY - U8280260.
mm 76%
ID is Real Fill
ECT Bobbin probe, 16.2 mm (0.638 in.), 50 kHz
8 inches OD 0.75 BWG 21 0.69 Factor is Brass (Admiralty) - SB111, SB543 TEA N20 TEA-162-050-N20 center frequency, 20 m (65.6 ft.) cable.
NORMALLY AVAILABLE FOR IMMEDIATE DELIVERY - U8280626.
inches 86%
ID is Real Fill
specify MFL High-Saturation probe, 18.7 mm (0.736 in.), NORMALLY AVAILABLE FOR IMMEDIATE DELIVERY - U8280246.
9 inches OD 1.00
->
0.080 0.84 Factor is Carbon steel - A178, A179, A192, A210, A214 TFB N20 TFB-187-N20 20 m (65.6 ft.) cable. Changeable stainless half-rings total probe diameter 19.2 mm (0.76").
inches 77%
10
11
12
13
14
15
16
17
18
19
Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.
1 Enter the TUBE parameters 2 Select the 3 Read or copy the automatic probe INFORMATION
PROBE data
Wall Missin Force a Fill
No OD / Thicknes OD Real Fill Probe Part
Units Value Thicknes g fill Factor Material Model Cable Probe Description Comment/Stock probe
. ID
s
s finned?
ID/OD factor? (%)
factor Number
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.
1 Enter the TUBE parameters 2 Select the 3 Read or copy the automatic probe INFORMATION
PROBE data
Wall Missin Force a Fill
No OD / Thicknes OD Real Fill Probe Part
Units Value Thicknes g fill Factor Material Model Cable Probe Description Comment/Stock probe
. ID
s
s finned?
ID/OD factor? (%)
factor Number
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.
1 Enter the TUBE parameters 2 Select the 3 Read or copy the automatic probe INFORMATION
PROBE data
Wall Missin Force a Fill
No OD / Thicknes OD Real Fill Probe Part
Units Value Thicknes g fill Factor Material Model Cable Probe Description Comment/Stock probe
. ID
s
s finned?
ID/OD factor? (%)
factor Number
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.
1 Enter the TUBE parameters 2 Select the 3 Read or copy the automatic probe INFORMATION
PROBE data
Wall Missin Force a Fill
No OD / Thicknes OD Real Fill Probe Part
Units Value Thicknes g fill Factor Material Model Cable Probe Description Comment/Stock probe
. ID
s
s finned?
ID/OD factor? (%)
factor Number
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
Instructions:
1) Complete the TUBE parameter and PROBE data fields (please refer to the "Probe and Accessories catalog" for more information about probes).
2) Do not modify the yellow, blue, or comment cells because they contain formulas.
3) Copy the cell contents and paste them into a new Excel worksheet using the "Values only" paste option.
Tip: Drag the mouse over the column headers to view pop-up information.
1 Enter the TUBE parameters 2 Select the 3 Read or copy the automatic probe INFORMATION
PROBE data
Wall Missin Force a Fill
No OD / Thicknes OD Real Fill Probe Part
Units Value Thicknes g fill Factor Material Model Cable Probe Description Comment/Stock probe
. ID
s
s finned?
ID/OD factor? (%)
factor Number
96
97
98
99
100
1 Select the PROBE specifications 2 Read or copy the automatic probe INFORMATION
Probe Dia.
No. Model (mm x 10, Freq. Cable Probe Part Number Probe Description Comment/Stock probe
0.2mm rounded down.
145 = 14.4 mm)
Use probe cable TEZ-ACS-N20. Type K and lenghts of 15 m (65') and 30 m (100') also
ECT Air conditioner probe, detachable, 14.8 mm
5 TED 149 050 TED-148-050 (0.583 in.), 50 kHz center frequency.
available - see Tube Probe Catalog. Resulting probe diameter is different from requested.
Make sure the probe can work for your application.
10
11
12
<
Page 9 / 12
ECT-frequency calculation tool
MultiScan MS5800 tube inspection: Internal probes
Result
F90 is the optimal (center) frequency (kHz) ###
ρ r is the electrical resistivity (mWcm) ###
F90 = 3
t2μ t is the tube thickness (mm) Result
m is the relative permeability (dimensionless)
OD (Outside Diameter)
Diameter (opt for ID if
1 Enter the tube dimensio the actual value is known) 25.400 mm
BWG (Birmingham Wire Gage) tube thickness chart Inches vs. mm converter