CalcuLuX Area 5.0b


Date: 11-05-2019

Table of Contents

1. Project Description 3

1.1 3-D Project Overview 3


1.2 Top Project Overview 4
1.3 Left Project Overview 5
1.4 Right Project Overview 6
1.5 Front Project Overview 7
1.6 Back Project Overview 8

2. Summary 9

2.1 General Information 9


2.2 Project Luminaires 9
2.3 Calculation Results 9

3. Calculation Results 10

3.1 Grid: Textual Table 10


3.2 Grid: Iso Contour 11

4. Luminaire Details 12

4.1 Project Luminaires 12

5. Installation Data 13

5.1 Legends 13
5.2 Luminaire Positioning and Orientation 13

6. Financial Information 14

6.1 Installation Data 14


6.2 Luminaire Information 14
6.3 Total cost 14

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 2/14


Date: 11-05-2019

1. Project Description

1.1 3-D Project Overview

Z Y

A FGS103

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 3/14


Date: 11-05-2019

1.2 Top Project Overview


21
16
11
6
1
Y(m)

A
-4
-9
-14
-19
-24

-20 -15 -10 -5 0 5 10 15 20


X(m)

A FGS103

Scale
1:250

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 4/14


Date: 11-05-2019

1.3 Left Project Overview


25
20
15
10

A
5
Z(m)
0
-5
-10
-15
-20

22 17 12 7 2 -3 -8 -13 -18
Y(m)

A FGS103

Scale
1:250

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 5/14


Date: 11-05-2019

1.4 Right Project Overview


25
20
15
10

A
5
Z(m)
0
-5
-10
-15
-20

-22 -17 -12 -7 -2 3 8 13 18


Y(m)

A FGS103

Scale
1:250

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 6/14


Date: 11-05-2019

1.5 Front Project Overview


11.5
10.5
9.5
8.5

A
7.5
6.5
5.5
4.5
Z(m)
3.5
2.5
1.5
0.5
-0.5
-1.5
-2.5
-3.5

-4.5 -3.5 -2.5 -1.5 -0.5 0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5 8.5
X(m)

A FGS103

Scale
1:75

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 7/14


Date: 11-05-2019

1.6 Back Project Overview


11.5
10.5
9.5
8.5

A
7.5
6.5
5.5
4.5
Z(m)
3.5
2.5
1.5
0.5
-0.5
-1.5
-2.5
-3.5

8.5 7.5 6.5 5.5 4.5 3.5 2.5 1.5 0.5 -0.5 -1.5 -2.5 -3.5 -4.5
X(m)

A FGS103

Scale
1:75

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 8/14


Date: 11-05-2019

2. Summary

2.1 General Information

The overall maintenance factor used for this project is 1.00.

2.2 Project Luminaires

Code Qty Luminaire Type Lamp Type Power (W) Flux (lm)
A 2 FGS103 1 * SOX-E18W 25.7 1 * 1770

The total installed power: 0.05 (kWatt)

Number of Luminaires Per Arrangement:


Luminaire
Arrangement Code Power (kWatt)
A
Point 2 0.05

2.3 Calculation Results

(Il)luminance Calculations:
Calculation Type Unit Ave Min/Ave Min/Max
Grid Surface Illuminance lux 1.17 0.09 0.03

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 9/14


Date: 11-05-2019

3. Calculation Results

3.1 Grid: Textual Table

Grid : Grid at Z = 0.00 m


Calculation : Surface Illuminance (lux)

X (m) -4.00 -3.00 -2.00 -1.00 0.00 1.00 2.00 3.00 4.00
Y (m)
20.00 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.5 0.5
15.00 0.4 0.5 0.5 0.6 0.6 0.7 0.7 0.8 0.9
10.00 0.6 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.7
5.00 1.0 1.1 1.3 1.6 1.8 2.0 2.2 2.5 2.7
0.00 1.3 1.6 1.8 2.1 2.4 2.8 3.0 3.3 3.6>
-5.00 1.5 1.8 2.0 2.3 2.5 2.8 3.2 3.2 3.2
-10.00 0.9 0.9 1.0 1.1 1.2 1.3 1.2 1.1 1.1
-15.00 0.4 0.4 0.4 0.4 0.4 0.4 0.5 0.5 0.4
-20.00 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1<

Average Min/Ave Min/Max Project maintenance factor


1.17 0.09 0.03 1.00

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 10/14


Date: 11-05-2019

3.2 Grid: Iso Contour

Grid : Grid at Z = 0.00 m


Calculation : Surface Illuminance (lux)
21

5
0.
16
11

5
1.
2
6
1
Y(m)

A
3
-4

2.5

2
1.5
-9

1
-14

0.5
-19
-24

-20 -15 -10 -5 0 5 10 15 20


X(m)

A FGS103

Average Min/Ave Min/Max Project maintenance factor Scale


1.17 0.09 0.03 1.00 1:250

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 11/14


Date: 11-05-2019

4. Luminaire Details

4.1 Project Luminaires

FGS103 1xSOX-E18W Luminous Intensity Diagram (candela/1000 lumen)


120o 150o 180o 150o 120o

90o 90o

60o 60o
Light output ratios
DLOR : 0.69
ULOR : 0.06
TLOR : 0.75 250
Ballast : Standard
Lamp flux : 1770 lm
Luminaire wattage : 25.7 W
Measurement code : D574000000

30o 0o 30o
C = 180 o C = 0o
C = 270 o C = 90o
C = 350 o Imax C = 170o

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 12/14


Date: 11-05-2019

5. Installation Data

5.1 Legends

Project Luminaires:
Code Qty Luminaire Type Lamp Type Flux (lm)
A 2 FGS103 1 * SOX-E18W 1 * 1770

5.2 Luminaire Positioning and Orientation

Qty and Position Aiming Angles


Code
X (m) Y (m) Z (m) Rot. Tilt90 Tilt0
1*A 8.00 0.00 8.00 165.00 65.00 0.00
1*A 8.00 0.00 8.00 135.00 65.00 0.00

CalcuLuX Area 5.0b Philips Lighting B.V. Page: 13/14


Date: 11-05-2019

6. Financial Information

6.1 Installation Data

Burning hours/year 0 hr
Amortization period 1.0 yr
Interest rate 0.0 %
kWh price 0.00

6.2 Luminaire Information

Prices ()
Relamping
Project Luminaires Qty
period (yr)
Lamp Luminaire Installation Maintenance
FGS103 2 0.00 0.00 0.00 0.00 1.00

6.3 Total cost

Costs per year


Energy 0.00
Investment 0.00
Lamps 0.00
Maintenance 0.00
-------------
Total 0.00

Total investment 0.00