Engineering Procurement & Construction (EPC)

Bid Documents
For
Gauge Conversion Of Katosan Road – Becharaji –
Chanasma – Ranuj (65 KM) Metre Gauge to Broad
Gauge Rail Section with 25 KV Electrification Of
Katosan Road – Becharaji (25 KM) section only in
Ahmedabad Division of Western Railway

VOLUME – IV

Typical Plans & Drawings

Gujarat Rail Infrastructure Development Corporation Ltd.


Gandhinagar
LISTOF DRAWINGS
1. Enclosure A: Station Yard Plans(ESPs)
S. No. Drawing No. Drawing Title
GRIDE/KTRD-
1 Engineering Scale Plan of Katosan Road (B-Class) Station
RUJ/GC/KTRD/ESP/1
GRIDE/KTRD-
2 Engineering Scale Plan of Dhanpura (D-Class) Station
RUJ/GC/DNPR/ESP/2
GRIDE/KTRD-
3 Engineering Scale Plan of Rantej (D-Class) Station
RUJ/GC/RTJ/ESP/3
GRIDE/KTRD-
4 Engineering Scale Plan of Dethli (D-Class) Station
RUJ/GC/DHLI/ESP/4
GRIDE/KTRD- Engineering Scale Plan of Becharaji (B-Class) Station incl.
5
RUJ/GC/BHRJ/ESP/5 MSIL Siding connectivity.
GRIDE/KTRD-
6 Engineering Scale Plan of Sankhalpur (D-Class) Station
RUJ/GC/SNKP/ESP/6
GRIDE/KTRD-
7 Engineering Scale Plan of Venpura (D-Class) Station
RUJ/GC/VNP/ESP/7
GRIDE/KTRD-
8 Engineering Scale Plan of Khambel (D-Class) Station
RUJ/GC/KVH/ESP/8
GRIDE/KTRD-
9 Engineering Scale Plan of Bhatsar (D-Class) Station
RUJ/GC/BATS/ESP/9
GRIDE/KTRD-
10 Engineering Scale Plan of Brahmanvada (D-Class) Station
RUJ/GC/BMDI/ESP/10
GRIDE/KTRD-
11 Engineering Scale Plan of Chanasama (B-Class) Station
RUJ/GC/CSMA/ESP/11
GRIDE/KTRD-
12 Engineering Scale Plan of Jintoda (D-Class) Station
RUJ/GC/JEO/ESP/12
GRIDE/KTRD-
13 Engineering Scale Plan of Wa-sojintra (D-Class) Station
RUJ/GC/WSR/ESP/13
GRIDE/KTRD-
14 Engineering Scale Plan of Ranuj (B-Class) Station
RUJ/GC/RUJ/ESP/14
2. Enclosure B: Bridge drawings

Part 1: Drawings of BG std with MBG loading existing bridges are attached in Volume IV

BRID STANDARD
SR. SECTION & DRAWING
GE DESCRIPTION OF
NO KM NO
NO LOADING

GAD-1 X 3.66M RCC KTRD-BHRJ CAO/C/18300/


1. 63 MBG-1987
SLAB NMC X-ING (R-14) 45/4-5 D-NMC

GAD- 1X 2.0M X 2.0M


KTRD-BHRJ CAO/C/18301/
2. 64 RCC BOX,NMC XING(R- MBG-1987
45/7-8 D-NMC
14)
GAD- 4 X 18.00M PSC CAO/C/17978/
KTRD-BHRJ
3. 64-A GIRDER (DHANPURA D-KTRD- MBG-1987
45/10-11
MAIN CANAL) BHRJ/R
GAD- 4 X 18.00M PSC
CAO/C/17978/
GIRDER (DHANPURA KTRD-BHRJ
D-KTRD-
64-A MAIN CANAL) 45/10-11 MBG-1987
4. BHRJ/R
64-A RCC Details of PILE for KTRD-BHRJ MBG-1987
CAO/C/18597/
PIER(Dhanpura Main Canal 45/10-11
D-KTRD-BHRJ
Crossing)R-14
RCC Details of PILE for
PIER (Dhanpura Main
Canal Crossing)R-14 CAO/C/18597/
KTRD-BHRJ
D-KTRD-BHRJ
64-A (4 X 18.00M PSC 45/10-11 MBG-1987
5. GIRDER) RCC DETAILS CAO/C/18970/
64-A KTRD-BHRJ MBG-1987
OF Abutment pile Cap, D-KTRD-
45/10-11
Abutment,Dirt Wall,Return CSMA
Wall and Side Column
(Dhanpura Main Canal)r-14

RC Details of Pile Capfor KTRD-BHRJ CAO/C/19009/


6. 64-A MBG-1987
Pier and Pier,Dhanpura 45/10-11 D-KTRD-BHRJ
Main Canal(R-14)
(GAD) 3 X 1200MM DIA
KTRD-BHRJ CAO/C/19199/
7. 64-A RCC PIPE Dhanpura Main MBG-1987
45/10-11 D-KTRD-BHRJ
Canal(R-14)
BRID STANDARD
SR. SECTION & DRAWING
GE DESCRIPTION OF
NO KM NO
NO LOADING
(RCC BOX 1 X 5.0M X
CAO/C/18697/
8. 64-B 5.506M) Details of RCC KTRD-BHRJ
D-NMC
BOX (RUB) MBG-1987
GAD-1 X 3.5M X 2.0M
KTRD- CAO/C/18058/
9. 65 RCC BOX NMC X-ING MBG-1987
BHRJ, 46/2-3 D-NMC
(R-14)
GAD- 1 X 2.0M X2.0M KTRD-BHRJ CAO/C/18059/
10. 67 MBG-1987
RCC BOX 46/5-6 D-NMC
GAD-1 X 2.44M RCC KTRD-BHRJ CAO/C/18060/
11. 68 MBG-1987
SLAB(NCX-14) 46/8-9 D-NMC
2 X6.0M X 4.0M RCC
KLL-CSMA CAO/C/18989/
12. 75-A BOX,RCC Details of Twin MBG-1987
49/1-2 D-KLL-CSMA
Box
GAD-1 X 1.0M X 1.5M
KLL-CSMA CAO/C/19428/
13. 75-A1 RCC BOX (DABHSAR MBG-1987
49/1-2 D-KLL-CSMA
MINOR CANAL
2 X 6.0M X4.299M RCC
KLL-CSMA CAO/C/19428/
75-A BOX (JINJUWADA MBG-1987
49/1-2 D-KLL-CSMA
BRANCH CANAL)
1 X 1.0M X1.5M RCC
KLL-CSMA CAO/C/19428/
75-A2 BOX(AKWA MINOR MBG-1987
49/1-2 D-KLL-CSMA
14. CANAL)
GAD-1 X 1.0M X 1.50M
RCC BOX Syphon(Push
KTRD-BHRJ CAO/C/19393/
75-A Thro) Rampura minor Canal MBG-1987
49/1-2 D-KLL-CSMA
near village Rantej(NCX-
06)

GAD-1 X 2.0M X1.50M


KLL-CSMA CAO/C/19395/
15. 106-A RCC BOX SYPHONE for MBG-1987
Mnawada Distributory 63/7-8 D-VG
Canal (NCX-47)
26-
A,64-
RCC Details of boxes(R- CAO/C/18338/
16. A2,12 MBG-1987
12,R-13,R-14,R-15) D-NMC
2-C &
44-B
BRID STANDARD
SR. SECTION & DRAWING
GE DESCRIPTION OF
NO KM NO
NO LOADING
GAD-6 X 3.05M X 3.05M KTRD- CAO/C/18713/
17. 122 RCC BOX (Chanasma Main CSMA 81/7- D-KTRD- MBG-1987
Canal) R-15 8 CSMA

GAD(RUB) 1 X 5.0M X BHRJ-


122-B 4.953M RCC BOX CAO/C/18460/
18. CSMA 82/1- MBG-1987
RUB D-BHRJ-CSMA
(BRAMANWADA MAIN 2
CANAL) R-15
RC Details of
BHRJ-
122-B BOX,Retaining Wall(MASS CAO/C/18913/
19. CSMA 82/1- MBG-1987
RUB CC),Wearing Coat,Ballast D-BHRJ-CSMA
2
Wall,Cut Off Wall(R-15)
RC Details of BOX,Mass
CC Retaining Wall,Wearing
CAO/C/18914/
20. 122-C Coat,Ballast Wall,Cut OFF MBG-1987
D-NMC
Wall(Brahmanwada Main
Canal) R-15

GAD-1 X 3.66M X 2.038M BHRJ-


CAO/C/18394/
21. 123 RCC BOX (Brahmanwada CSMA 82/1- MBG-1987
D-NMC
main canal)R-15 2

RC Details of Pier Cap at


Pier Location P1,P2&P3(4X BHRJ-
CAO/C/18964/
22. 18.00 PSC Girder) CSMA 81/7- MBG-1987
D-BHRJ-CSMA
Brahmanwada Main Canal, 8
R-15
CAO/C/20666/1
IN RANUJ /2/D-MSH-PTN
27-A/ GAD- 1 X 6.10M RCC
23. YARD 26/9- & MBG-1987
144 BOX
10 CAO/C/20666/2
KM:101.48 /2/D-MSH-PTN
CAO/C/20637/1
IN RANUJ /2/D-MSH-PTN
27/ GAD- 1 X 6.10M RCC
24. YARD 26/8- & MBG-1987
145 BOX
9 CAO/C/20637/2
KM:101.526 /2/D-MSH-PTN
Part 2: Major Bridges : - Typical Plans/GAD are attached in Volume IV

S.No. Bridge Drawing Span Remarks


1. Typical Drawing 1 9 x 18.3 m PSC Girder
For Reference only
2. Typical Drawing 2 4 x 6.10 PSC Slab

Part 3: Minor Bridges : - Typical Plans/GAD are attached in Volume IV

S.No. Bridge Drawing Span Remarks


1. Typical Drawing 3 1 x 2.3 x 2.156 m RCC Box
2. Typical Drawing 4 2 x 6.0 x 3.625 m RCC Box For Reference only
3. Typical Drawing 5 4 x 4 x 5.65 m RCC Box

Part 4: RUB : - Typical Plans/GAD are attached in Volume IV

S.No. RUB Drawing Span Remarks


1. 2 x 5.5 x 5.5 m in leu of LC
Typical Drawing 6
no. 43 C (Manned)
2. Typical Drawing 7 1 x 4.0 x 4.42 m RCC Box in For Reference only
leu of LC no 49 C
(UnManned)
3. Enclosure C: Longitudinal section and Plan Drawings

S.
Drawing No. Drawing Title
No.
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
1
RUJ/GC/P&P/01 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
Plan and Section (Ch: -2120 to Ch: 5000) Sheet 1
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
2
RUJ/GC/P&P/02 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 5000 to Ch: 10000) Sheet 2
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
3
RUJ/GC/P&P/03 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 10000 to Ch: 15000) Sheet 3
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
4
RUJ/GC/P&P/04 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 15000 to Ch: 20000) Sheet 4
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
5
RUJ/GC/P&P/05 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 20000 to Ch: 25000) Sheet 5
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
6
RUJ/GC/P&P/06 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 25000 to Ch: 30000) Sheet 6
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
7
RUJ/GC/P&P/07 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 30000 to Ch:35000) Sheet 7
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
8
RUJ/GC/P&P/08 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 35000 to Ch:40000) Sheet 8
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
9
RUJ/GC/P&P/09 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 40000 to Ch:45000) Sheet 9
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
10
RUJ/GC/P&P/10 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 45000 to Ch: 50000) Sheet 10
S.
Drawing No. Drawing Title
No.
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
11
RUJ/GC/P&P/11 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 50000 to Ch: 55000) Sheet 11
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
12
RUJ/GC/P&P/12 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 55000 to Ch: 60000) Sheet 12
Ahmedabad Division Final Location Survey for Gauge Conversion
GRIDE/KTRD- of Existing Metre gauge Line Between km 37.23 to km 101.996
13
RUJ/GC/P&P/13 Katosan Road (Chainage 0.00) to Ranuj section (Chainage 64.77) –
– Plan and Section (Ch: 60000 to Ch: 65480) Sheet 13
GRIDE/KTRD-
MSIL Siding taking off from Becharaji Station-
14 RUJ/MSIL-
Plan and Section (Ch: 0.00 to Ch 3000.00 approx) Sheet 14
Sdg/01
4. Enclosure D: Standard RDSO Drawings
S. No. Drawing No. Drawing Title

RDSO/B-10274 Post tensioned PSC Slab 6.1m 25T loading-2units


1.
RDSO/B-10272 Post tensioned PSC Slab 9.15m 25T loading-2units
2.
RDSO/B-10271 Post tensioned PSC Slab 12.2m 25T loading-4units
3.
Pre stressed 2I Concrete girder 18.3m 25T loading.
RDSO/B-10273 Suitable upto seismic zone-V(Post Tensioned)
4.
Standard loading of single box culvert GAD 25T loading
RDSO/B-10152/R 2008
5.
Standard drawing of double box culvert GAD DFC
RDSO/B-10154 loading (32.5 axle loading)
6.
RDSO/T-6219 Stacking of rails
7.
RDSO/ETI/C/0068 Protective screen at FOB
8.
RDSO/T-3950 Buffer stop for snag dead end
9.
Road surface with Pre Cast PCC blocks at Level
RDSO/M-00003 crossing
10.
RDSO-RA-10501 Passanger platform roofs standard type sections (BG)
11.
RDSO/M-0001 Height Gauge for RUB and LC.
12.
5. Enclosure E: Signalling Drawings
S. No. Drawing Reference

1. SG(SP)/KTRD/40--

2. SG(SP)/BHRJ/40--

3. SG(SP)/CSMA/40--

4. SG(SP)/RUJ/40--

5. Apparatus case single and half SK-783 1/2, 2/2

Foundation for shunt signal and main


6. R-ST/11173
signal

7. Enamelled number plate R-ST-11393

Typical installation of earth for S&T


8. SDO/RDSO/E&B-001
installations

Typical bonding and earthing


9. SDO/RDSO/E&B-002
connection for signalling equipment

10. Test Board R-ST/C/105-A

11. Circuit processing board R-ST/C/105-B

12. Foundation of Apparatus case (Half) SK-747

13. Foundation of Apparatus case (Single) SK-748

14. Relay room typical rack arrangement SK-727/A

15. A/AG/C/P/G board Sa-23455-56, RST-11445 & SA- 23476-77

16. Earth Electrode assembly NGP/S&T/C/308

Track lead junction boxes made from


17. RST-11509
fibre glass along with terminal blocks

Adjustable track feed resistance disk


18. type 30ohms with latest amendments SA-20166/M
(with phenolic module base)

19. Earth electrode with enclosure S&T/SK/881

20. Cartridge fuse block PBT SA-23748” ALT-4”

21. Cable route marker FRP type RST/C/203


6. Enclosure: F Civil work-related drawings
S.No. Drawing Title Drawing No. Remarks/Railway
RCC Details of curtain
1 wall and drop wall CPM/ADI/3683/D-VNRD-SUNR WESTERN RLY
DRG.NO:SR/CN.22182/1 &
2 RCC retaining wall 22183/1 SOUTHERN RLY
3 Platform wall
4 RCC toe wall
Details of Gangway
5 girder
Details of boundary
6 wall on RCC column CPM/ADI/3688/D-VNRD-SUNR WESTERN RLY
Proposed Track
formation for heavy
7 axle load-25T
Typical cross-sections
Embankment/Cutting
8 upto 6.0m
Level crossing (Details
of infrastructure to be
9 provided) SOUTHERN RLY
SERVICE BLDG
B- Class station
1 Building
Flag station Building D
2 class CPM/ADI/4825(1)B/ADI-HMT WESTERN RLY
DRG.NO. SR/RVNL/VM/DG-
DOUBLING/ALU-
3 SSE Office VLDEJE/2012 SOUTHERN RLY
Type plan of Duty
bunk-interlocked level TYPE PLAN NO. L.C.-27/2014
4 crossing HQ. WESTERN RLY
Duty Bunk (single
5 room) DyCE/C/P&D/ADI/B-VG-VANI WESTERN RLY
Office for
IOW/PWI/BRI AND
6 SIGNAL INSPECTOR CEO.DRG. NO. CE 149 SOUTHERN RLY
7 Signalling cable hut CSTE 6222
STAFF QRS.
TYPE-II two storied DRG. NO. CPM-ADI/3826/B-
1 (G+1) VG-PNU
TYPE-II two storied DRG. NO. CPM-ADI/3792/B-
2 (G+2) ADI-PNU
3 TYPE-III Single Storey CPM/ADI/3811/B-VG-SUNR
S.No. Drawing Title Drawing No. Remarks/Railway
DRG. NO. CPM-ADI/3828/B-
4 TYPE-IV Single Storey ADI-PNU
Sign Boards:
1 Gradient post
Kilometre post RCC
2 fixing
DRG No. DY. CE/C/II/ADI/
3 SEJ board /SK. VG-SIOB-DBLG.
DRG No. DY. CE/C/II/ADI/
4 Curve board /SK. VG-SIOB-DBLG.
DRG No. DY. CE/C/II/ADI/
5 Gang Board /SK. VG-SIOB-DBLG.
6 Hectometer post details
Hectometer post fixing
7 arrangements
RCC Station name
8 boards Das per DRG no. 7119/10A
Foundation details of
9 whistle board CBE/SK/637/2015
10 Whistle indicator board

11 Speed breaker Design Drg. No. CB/LC/SK-5


Speed breaker indicator
( for manned &
12 Unmanned LC)
Road warning board
(Single strip) for
13 manned LC
Road warning board
(double strip) for
14 manned LC
Note: Where Drawing numbers are not mentioned, Standard Railway drawings shall be
followed/adopted.
7. Enclosure G: Signalling Other Drawings
Signalling Other Drawings
Method of laying cables direct in trench S&T/C/SK/100
Position of trench for cable laying S&T/C/SK/167
Arrangement of RCC pipe under metal road S&T/C/SK/168
Arrangement of cable RCC pipe under track crossing S&T/C/SK/160
GI pipe on culverts and brick channelling in approach of
S&T/C/SK/170
culverts / bridges
Laying cables in rocky area S&T/C/SK/171
Provision of type earth by GI pipe S&T/C/SK
8. Enclosure H: Electrical Drawings

S.No. Drawing Title Drawing No. Remarks/Railway


Volume Chart for Anchor block in Normal Soil ETI/OHE/G/01403
1. Volume Chart for Portal Foundation in Normal
Soil ETI/C/0058/68
Annexure 1 : List of Land Plans

S.No. Km From Km To
1 35.000 38.000
2 38.000 41.000
3 41.000 44.000
4 44.000 49.000
5 48.618 51.660
6 51.660 54.877
7 54.877 58.100
8 58.100 61.318
9 61.318 62.785
10 62.672 67.946
11 67.946 73.017
12 73.017 77.844
13 77.844 82.617
14 82.617 89.107
15 89.107 92.325
16 92.325 97.152
17 97.152 101.790

You might also like