Ordering number: EN 2237B

Monolithic Linear IC

LA4275
6.0 W AF Power Amplifier
for Home Stereo, TV Use

Features Package Dimensions


. Small-sized package of 7-pin SIP unit : mm
. High power and low distortion 3075-SIP7H
PO = 6.0 W at VCC = 25 V, RL = 8 Ω,
f = 1 kHz, THD = 1.0% [LA4275]
THD = 0.1% at VCC = 25 V, RL = 8 Ω,
f = 1 kHz, PO = 2 W
. Minimum number of external parts required (no bootstrap
capacitor required)
. Low pop noise at the time of power switch ON/OFF
. Excellent ripple rejection (55 dB typ.)
. Wide operating voltage range (10 V to 32 V)
. Protector against abnormalities built in (thermal shutdown,
overvoltage)

Specifications SANYO : SIP7H

Maximum Ratings at Ta = 25°C

Parameter Symbol Conditions Ratings Unit


Maximum supply voltage VCC max Quiescent 35 V
Maximum output current IO peak 3.5 A
Allowable power dissipation Pd max With heat sink 10 W
Operating temperature Topr –20 to +75 °C
Storage temperature Tstg –40 to +150 °C

Operating Conditions at Ta = 25°C

Parameter Symbol Conditions Ratings Unit


Recommended supply voltage VCC 25 V
Operating voltage range VCC op 10 to 32 V
Recommended load resistance RL 8 to 16 Ω

Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft’s
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.

SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters


TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
O3096HA(II)/D228YT/8016KI/O155KI,TS No.2237-1/3
LA4275

Operating Characteristics at Ta = 25°C, VCC = 25 V, RL = 8 Ω, f = 1 kHz, Rg = 600 Ω,


See specified Test Circuit.

Parameter Symbol Conditions min typ max Unit


Quiescent current ICCO Quiescent 30 60 mA
Voltage gain VG 38 40 42 dB
Output power PO THD = 1% 5.0 6.0 W
Total harmonic distortion THD PO = 2 W 0.1 0.8 %
Output noise voltage VNO Rg = 10 kΩ, BW = 20 Hz to 20 kHz 0.25 1.0 mV
Ripple rejection SVRR Rg = 10 kΩ, fR = 100 Hz, VR = 0 dBm 45 55 dB

Equivalent Circuit Block Diagram and Pin Assignment

Pd max – Ta

Allowable power dissipation, Pd max – W


Al heat sink
Mounting torque
39N·cm
With silicone
grease applied

Infinite
heat sink

No heat sink

Ambient temperature, Ta – °C

Sample Application Circuit (Test Circuit)

Polyester
film
capacitor

No. 2237-2/3
LA4275

Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer’s
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customer’s products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products(including technical data,services) described or
contained herein are controlled under any of applicable local export control laws and regulations,
such products must not be exported without obtaining the export license from the authorities
concerned in accordance with the above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the “Delivery Specification”
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only ; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.

This catalog provides information as of October, 1996. Specifications and information herein are subject to
change without notice.

PS No. 2237-3/3
This datasheet has been download from:

www.datasheetcatalog.com

Datasheets for electronics components.

You might also like