Project: Mombina Janbetan Menghubunghan Kg. Labor Kii Ke Ko. Lambor Kanan (Merentas!Sungat Perak) VASCO SCAFFOLD SDN. BHD. (880828-X) Lot 71, Jalan Haji Sirt, 42100 Klang, Selangor D.E. Tol: 603-32919721 Fax: 603-22919723 Design Calculation For Vasco 60 As Temporary Support For Precast Giant U-Girder (Abut A to Abut B) Project : Membina Jambatan Menghubungkan Kg. Lambor Kiri Ke Kg. Lambor Kanan (Merentasi Sungai Perak) Contractor : Kumpulan Awambina Sdn. Bhd. ‘Project: Membina ambaten Menghubungkan Ke, Lambor Ki Ke Ka, Lambor Kanan (Merentei Sungai Por) ‘Untrod The purpose of this design caculation note is to verily the loads on the heavy duty Vasco 60 ‘Shoring System as temporary suppor for Precast Giant U-Girder ‘The design of falsework is based on the folowing standards:- |) BS EN 12612 "Falsework - Performance requirements and general design", li) BS 5975 "Code of Practice ‘or Falsework’, fi) Other rolevant documents or test reports, 2) Bearing Capacity of Shoring System From Test Report, Ultimate Bearing Capacity of StandardiLeg = 168.18 kNiLeg Project: Mamaina Jambatan Mengrubungkan Kg. Lambor kt Ke Kg, Lambe Kanan (Meventasi Sungai 3) Design Calculation A) Check Capacity of Vasco 60 Shoring System 1) Precast Giant U-Girder (Critical ase! Use 1mm Tower wih Linkage 10m (Sectional Linkige 1.5) Concrete (UGiiden) = 28 tons sogrent Service Load Yexcisen ont Formvore = 15x50) x05 ‘Shoring Weight seo Toad 742 Legs Loads /Leg Safety Factor 168002233 = 76 > 20 ors 260.00 4N ‘S634KN 1.88 kN O50 kN 268.00 12, 22.33