1.

    Data Profil Struktur Atap

a.
Kuda-kuda
Tipe : Gable
Material : Baja IWF (wide flange)
Dimensi : IWF 200X150X6X9 mm

H = 194 mm
B = 150 mm
A = 38.8 cm2
W = 30.6 kg/m
367.2 kg/12m

t1 = 6 mm
t2 = 9 mm
r = 12 mm
lx = 2675 cm4
ly = 507 cm4
Zx = 275.8 cm3
Zy = 67.6 cm3
ix = 8.3 cm
iy = 3.6 cm
Dari SAP :
rx = 8.29 cm
ry = 3.67 cm

b. 
Gording
Tipe : Gable
Material : Baja Lipped Channel
Dimensi : LC 200X75X20X3,2 mm

H = 200 mm
B = 75 mm
A = 11.81 cm2
C = 20 mm
tw/tf = 3.2 mm
rx = 15.8 cm
ry = 2.67 cm
lx = 716 cm4
ly = 84 cm4
Zx = 71.6 cm3
Zy = 15.8 cm3
Cy = 2.19 cm
Xo = 5.39 cm
J = 4030 cm4
Cw = 6779 cm6
Sx = 77.38 cm3
Sy = 22.85 cm3

c. 
Penutup Atap
Penutup Atap Statik
Nama Produk : Atap Union Clip Panel 660 (Zincalume Galvalume)
Spesifikasi
Sumber Bahan : Zincalume Z 150
Lapis Lindung : Zinc-Aluminium
Lebar Efektif : 660 mm
Panjang : 12 m (maks)
Gelombang : 4 Gelombang
Tebal : 0.4 mm
Jarak antar Gording : 1.4 m < 1,6 m (anjuran)
Berat : 3.1 kg/m2

Penutup Atap Dinamik
Nama Produk : Lovera (Adjustable Roof System)
Sumber Bahan : Almunium
Spesifikasi
Daun Lovera :
Tebal = 1 mm
Lebar = 200 mm
Panjang = 6000 mm (maks)
Berat = 8 kg/m2 (sudah termasuk rangka AP dan AG)
Putaran = 90° (bisa di adjustment)

Ambang Penyangga (AP) :


AP 75 :
Tebal = 1.35 mm
Lebar = 40 mm
Tinggi = 75 mm
Panjang = 6000 mm (panjang bisa disambung)

AP 100 :
Tebal = 1.35 mm
Lebar = 40 mm
Tinggi = 100 mm
Panjang = 6000 mm (panjang bisa disambung)

AP 125 :
Tebal = 1.35 mm
Lebar = 40 mm
Tinggi = 125 mm
Panjang = 6000 mm (panjang bisa disambung)

Ambang Gerak (AG) :


AG 75 :
Tebal = 1.35 mm
Lebar = 40 mm
Tinggi = 75 mm
Panjang = 6000 mm (panjang bisa disambung)

Asesoris / komponen lain :


Braket Siku 40 :
Braket U 75 :
Braket U 100 :
Braket U 125 :
Tebal = 4 mm
Tutup AP (PUA) :
Tutup AG (PUA) :
Tutup Daun (PUD) :
Tebal = 1.35 mm
Hollow
Adjuster

Mesin Otomatis :
Motor Lovera :
Power Supply = 220 V Ac
Motor = 24 V ; 50 watt
Output Power = 125 kg (push/pull)
Max Louvre Size = 20 m2
Limit Switch = Mechanical built in
Working Temp = 10 s/d 50 °C
Acuator Material = Aluminium IP54
Weight Motor = 2.5 kg
Back Up Power = 12 V DC 1.25 Ah
Box Unit = 0.5 kg

12
0
Mutu : BJ 52 diganti 1/9/16

W = 7849.0476 kg/m3
fy = 360 Mpa (N/mm)
fu = 520 Mpa (N/mm)
E = 200000 Mpa (N/mm)
Poisson’s Ratio = 0.3
G = 80000 Mpa (N/mm)

Kemiringan (α) : 28 °
Bentang : 20 m
Jarak antara :
= 5 m (Horizontal) = 5000 mm
Lk = 5.044 m (Miring 7,6°)
Berat (Wk) : 30.6 kg/m

Mutu : BJ 34

W = 7849.0476 kg/m3
fy = 210 Mpa (N/mm)
fu = 340 Mpa (N/mm)
E = 200000 Mpa (N/mm)
Poisson’s Ratio = 0.3
G = 80000 Mpa (N/mm)

Bentang : 20 m
Jarak antara : 1415.71 mm
Lgs = 1.4 m (Miring)
Berat (Wg) : 9.27 kg/m
= 0.0909 kN/m

Lgd (Atap Dinamik) = 1.25 m (setelah diperbaiki gording)

Galvalume)

angka AP dan AG)


2.    Pembebanan

a.
Peraturan
1. PPPURG 1987
2. SNI 1727:2013 - Beban Minimum Untuk Perancangan Bangunan Gedung Dan Struktur Lain

b.
Beban
1. Beban Mati (Dead Load) : Beban sendiri baja (IWF dan LC)

2. Beban Hidup (Live Load) :

Pekerja

3. Beban Hujan (Rain Load) :

PPPURG 1987
Hujan
Wh

4. Beban Angin (Wind Load)

PPPURG 1987
Tekanan Tiup
Koefisien Angin
(Gedung tertutup)
Angin Tekan

Wpush

Angin Hisap
Wpull

5. Beban Mati Tambahan (Super Dead Load)

Penutup Atap
Penutup Atap (Was)
Penutup Atap (Wad)

c.
Kombinasi Pembebanan

SNI 1727:2013
d.
Perhitungan Pembebanan
1. Beban Pada Gording :

Beban Hidup (Live Load)


Beban orang + peralatan

Beban Hujan (Rain Load)

Beban Angin (Wind Load)


Angin Tekan

Angin Hisap

Angin Tekan (Atap Dinamik)

Angin Hisap (Atap Dinamik)

Beban Mati Tambahan (Super Dead Load)


Penutup Atap Statik

Penutup Atap Dinamik


3. Beban Pada Kuda-Kuda (Titik/Terpusat) :

Beban Hidup (Live Load)


Beban orang + peralatan

Qh

Beban Hujan (Rain Load) Ph

Beban Angin (Wind Load)


Qat

Angin Tekan (Pat)

Qah

Angin Hisap (Pah)

Beban Mati Tambahan (Super Dead Load)


Qas

Penutup Atap Statik (Pas)

Qad

Penutup Atap Dinamik (Pad)


Gording

Beban Gording Dinamik (Nok)

Penutup Atap Statik + Gording +AP

rata-rata SDL

4. Beban Pada Kantilever


truktur Lain

= 100 kg (terpusat)

:
= (40-0,8α) kg/m2
= 17.6 kg/m2

:
= 25 kg/m2
:

= 0,02xα-0,4
= (0,02xα)-0,4
= 0.16 x Tekanan Tiup
= 4 kg/m2

= -0.4 x Tekanan Tiup


= 10 kg/m2 (min)

:
= 3.1 kg/m2
= 8 kg/m2

:
1,4 D
1,2 D + 1,6 L + 0,5 R
1,2 D + 1,6 R + 0,5 W
1,2 D + 1 W + L + 0,5 R
0,9 D + 1 W

: Beban Mati (Dead Load) :


= 100 kg Beban Gording =
0.98 kN/m =
= Wh x (1/2 Lg + 1/2 Lg)
= 24.64 kg/m Beban Gording Dinamik (Nok) =
0.24 kN/m =

:
= Wpush x (1/2 Lg + 1/2 Lg) Angin Tekan (Nok) =
= 5.6 kg/m =

= Wpull x (1/2 Lg + 1/2 Lg) Angin Hisap (Nok) =


= 14 kg/m (min) =
0.14 kN/m
= Wpush x (1/2 Lgd + 1/2 Lgd)
5

= Wpull x (1/2 Lgd + 1/2 Lgd)


12.5 (min)

Dead Load) :
= Wa x (1/2 Lg + 1/2 Lg) Penutup Atap Statik (Nok) =
= 4.34 kg/m =
= 0.0425615377 kN/m

= Wad x (1/2 Lgd + 1/2 Lgd) Penutup Atap Dinamik (Nok) =


10 =
: Beban Mati (Dead Load) :
= 100 kg Beban Kuda-kuda =
=
= (Wh x Lk x Lg) / Lk
= 24.64 kg/m

= Qh x Lk
= 124.28 kg
1.22 kN

:
= Wpush x Lk
= 20.18 kg/m
Diproyeksikan terhadap sumbu X dan Y
= Qat x (Lg / cos α) Pat x =
= 31.99 kg =
Pat y =
=
= Wpull x Lk Diproyeksikan terhadap sumbu X dan Y
= 50.44 kg/m Pah x =
=
= Qah x (Lg / cos α) Pah y =
= 79.97 kg (min) =
0.78 kN

Dead Load) :
= (Was x Lk x Lgs) / Lk Berat Alat Penyambung =
= 4.34 kg/m =
= Qas x Lk
= 21.89 kg

= (Wad x Lk x Lgd) / Lk Berat Mesin Atap Dinamik + Box Unit =


= 10 kg/m
= Qad x Lk
= 50.44 kg

= Wg x Lk
= 46.76 kg

= (Wg x 2) x Lk
= 93.52 kg
Beban Atap Dinamik Terbesar :
= 72.93 kg Penutup Atap Dinamik+Gording Dinamik+AP =

= 110.59 kg

Beban Mati (Dead Load) :


Beban Gording =
=
Wg Beban Gording = Wg
9.27 kg/m = 9.27 kg/m
0.09 kN/m
Wg x 2
18.54 kg/m

Wpush x 1/2 Lg Angin Tekan (Nok-Atap Dinamik) = Wpush x 1/2 Lgd


2.80 kg/m = 2.50 kg/m
` `
Wpull x 1/2 Lg Angin Hisap (Nok-Atap Dinamik) = Wpull x 1/2 Lgd
7 kg/m = 6.25 kg/m

Was x 1/2 Lg
2.17 kg/m

Wad x 1/2 Lgd


5 kg/m
Wk x Lg
42.84 kg
153.43 kg
1.50 kN

Pat x Sin α
15.03 kg
Pat x Cos α
28.25 kg

Pah x Sin α
37.59 kg (min)
Pah x Cos α
70.62 kg (min)

10% BS
4.284 kg

3 kg
148.24 kg

Wg
9.27 kg/m
3.    Cek Profil Gording

a.
Tinjauan terhadap tekuk lokal pelat sayap
SNI 03-1729-2002 hal 30 :
λ = B/tw
= 23.44

λp = 170 /
= 11.73
SNI 03-1729-2002 hal 31
λr = 370 / fr = 70
= 31.27

Karena λp < λ < λr, maka pelat sayap tidak kompak

Mp = Zx x fy <== sudah diperbaik


= 15036000
15.04 kNm

SNI 03-1729-2002 hal 36 :


Mr = Sx (fy-fr)
= 10832794
= 10.83 kNm

Mn = Mp-(Mp-Mr)
= 12.52 kNm

b.
Tinjauan terhadap tekuk lokal pelat badan
03-1729-2002 hal 31 :
λ = H/t
= 60.50

λp = 1680 /
= 115.93

λr = 2550 /
= 175.97

Karena λ < λp, maka pelat sayap kompak

SNI 03-1729-2002 hal 36 :


Mn = Mp
= 15.04 kNm

c.
Tinjauan terhadap tekuk lateral
Lb (jarak antar pengaku/sokongan lateral) :
Lb = 1800 mm edit 03-12-16
1.80 m

SNI 03-1729-2002 hal 36 :


Lp = 1,76 ry
= 1450.20 mm
1.45 m

fl = fy - fr
= 140 Mpa

SNI 03-1729-2002 hal 36 :


J=
= 8540849
= 8541 mm4

SNI 03-1729-2002 hal 38 :


X1 = (phi/Sx)
= 11527.57 Nmm

lw =
= 7871001600 mm6

SNI 03-1729-2002 hal 38 :


X2 = 4
= 0.00048 N/mm2

fl = fy – fr
= 140

Lr = ry
= 4520.63 mm
4.52 m

Karena Lp < L < Lr , maka penampang termasuk bentang menengah

SNI 03-1729-2002 hal 37 :


Cb = ≤ 2,3
= 1.44

SNI 03-1729-2002 hal 38 : dari Buku LRFD


Mn = Cb [Mp - (Mp – ((𝐿𝑏−𝐿𝑝)/(𝐿𝑟−𝐿𝑝))
Mr)] Mp
= 1.78 kNm
Kuat lentur penampang diambil yang terkecil dari 3 tinjauan di atas, Mn = 1.78 kNm

d.
Kombinasi antara geser dan lentur
SNI 03-1729-2002 hal 45 :
Kontrol kuat geser nominal gording tanpa pengaku lateral :
Kn = 5 +
= 5.14

(h/tw) ≤ 1.1

h/tw = 60.50

SNI 03-1729-2002 hal 45 :


Batas-batas :
= 1.1
= 76.99

SNI 03-1729-2002 hal 46 :


= 1.37
= 95.89

Maka penampang mengalami leleh geser

SNI 03-1729-2002 hal 46 :


Kuat geser badan tanpa adanya pengaku :
Aw = h x tw
= 619.52 mm2

Vn = 0,6 (fy Aw)


= 78059.52 Nmm
= 78.06 kN

Vu = 3.04 kN

SNI 03-1729-2002 hal 48 :


= 0.625 ≤ 1,375

= 1.18 OK!!

e.
Kontrol Lendutan
Lendutan Atap Statik
Berat sendiri Gording + Penutup Atap Statik:
= 13.61 kg/m
= 0.13 kN/m
qdx = qd x sin (Sudut Atap)°
= 0.06 kN/m
= 62659.67 N/mm

Px = 1 x sin (Sudut Atap)°


= 0.47 kN/m
= 469471.56 N/mm

δx =

= 3.03 mm

qdy = qd x cos (Sudut Atap)°


= 0.12 kN/m

Py = 1 x cos (Sudut Atap)°


= 0.88 kN/m

δy =

= 0.67 mm

SNI 03-1729-2002 hal 15 :


δ= + ≤

= 3.10 ≤ 20.83 OK!!

Lendutan Atap Dinamik


Berat sendiri Gording + Penutup Atap Dinamik:
= 17.27 kg/m
= 0.17 kN/m

qdx = qd x sin (Sudut Atap)°


= 0.08 kN/m
= 79.51 kN/mm

Px = 1 x sin (Sudut Atap)°


= 0.47 kN/m
= 469.47 kN/mm

δx =

= 3.84 mm
qdy = qd x cos (Sudut Atap)°
= 0.15 kN/m

Py = 1 x cos (Sudut Atap)°


= 0.88 kN/m

δy =

= 0.85 mm

SNI 03-1729-2002 hal 15 :


δ= + ≤

= 3.94 ≤ 20.83 OK!!

#Kesimpulan : profil Lipped Channel 200X75X20X3,2 memenuhi persyaratan (Aman)


I 03-1729-2002 hal 31:
Mpa

sudah diperbaiki (model 1 harus diperbaiki)


Label M3 (kNm) L (m)
626 1.8356 4.73745

MA = 1.8203 1.184363
MB = 1.347 2.368725
MC = 0.15 3.553088
Label Vu (kN) L (m)
628 3.037 0.41643

0.5490743
549.07433 N
Batas Lendutan
Batas Lendutan
MU
Vu
4.    Cek Batang Tarik (Trackstang)

Batang tarik (Trackstang) berfungsi untuk mengurangi lendutan gording pada arah
sumbu x (miring atap) sekaligus untuk mengurangi tegangan lendutan yang timbul pada arah
x. Beban-beban yang dipikul oleh trackstang yaitu beban-beban yang sejajar bidang atap
(sumbu x), maka gaya yang bekerja adalah gaya tarik Gx dan Px.

a.
Perhitungan Batang Tarik (Trackstang)
Gx = Beban sendiri gording + penutup atap sepanjang gording arah sumbu x
Px = Beban berguna arah sumbu x
Ptot = Gx + Px
= 0.58 kN

P = Ptot asalnya Ptot/2


= 0.58 kN

�/𝐹�
σ= ≤σ
= 160 Mpa

σ=σ
�/�
Fn =
= 3.63 mm2

Fbr = 125% x Fn
= 4.53 mm2

Fbr = 1/4 phi�^2


√((4.𝐹𝑏𝑟)/𝑝ℎ𝑖)
d=

= 2.40 mm

Maka, batang tarik yang dipakai adalah Ø 4 mm

Sesuai dengan yang ada dipasaran yaitu Ø 6 mm


mbul pada arah

ng arah sumbu x
5.    Cek Ikatan Angin

Ikatan angin hanya bekerja menahan gaya normal (axial) tarik saja. Adapun cara
kerjanya adalah apabila salah satu ikatan angin bekerja sebagai batang tarik, maka yang
lainnya tidak menahan apa-apa. Sebaliknya apabila arah angin berubah, maka secara
bergantian betang tersebut bekerja sebagai batang tarik.

a.
Perhitungan Ikatan Angin

L2 = 5.04 m
Gording

L1 =
11.33 m

Kuda Kuda

Ikatan Angin

Gambar Pembebanan pada ikatan Angin Atap tipe 1

N dicari dengan syarat keseimbangan, sedangkan P = gaya / tekanan angin.

tg β = 2.25

β = arc tg (β)
= 66.04 ° (Pakai Kalkulator)

P = 0,25 x L1
= 2.83 kN

∑H = 0

Nx = P
N cos β = P
N = �/cos⁡𝛽⁡

= 6.97 kN

�/𝐹�
σ=
Fn = �/�

= 43.59 mm2

Fbr = 125% x Fn
= 54.49 mm2

Fbr = 1 phi �^2


√((4⁡𝑥⁡𝐹𝑏𝑟)/𝑝ℎ𝑖)
dimana d=

= 8.33 mm

Maka, batang tarik yang dipakai adalah Ø 10 mm


, maka yang

Nx
P

Ny

an Angin Atap tipe 1


6.    Cek Profil Kuda-Kuda (Gable)

a.
Pembebanan Pada Balok Gable

GAMBAR DISTRIBUSI PEMBEBANAN DARI SAP

b.
Kontrol Profil Kuda-Kuda
1. Rafter (Sisi Miring)
Modulus Elastisitas = 200000
Modulus Geser (G) = 80000
Tegangan leleh (fy) = 360
Tegangan residu (fu) = 70

Data beban dan geometri struktur :


Momen Maksimum (Mu) = 35.5875
Gaya Geser Maksimum (Vu) = 28.733
Gaya Aksial (Nu) = 41.235
Momen Ujung Terkecil �_1𝑥 = 14.7014
Momen Ujung Terbesar�_2𝑥 = 35.5875
MA = 35.3784
MB = 35.1693
MC = 34.7879
𝐿_𝑥 = 11325.7
𝐿_� = 1415.71

Panjang Tekuk :
SNI 03-1729-2002 hal 32 :
Menentukan panjang tekuk rafter (Sendi-sendi):
SNI 03-1729-2002 hal 57/27 :
Lkx = Lx x 1
= 11325.7
Lky = Ly x 1
= 1415.71

Menentukan parameter kelangsingan rafter:


SNI 03-1729-2002 hal 27 :
1/𝜋⁡⁡𝐿𝑘𝑥/𝑟𝑥 √(𝑓�/𝐸)
λcx =
= 1.846
1/𝜋⁡⁡𝐿𝑘�/𝑟� √(𝑓�/𝐸)
λcy =
= 0.521

Menentukan daya dukung nominal rafter:


SNI 03-1729-2002 hal 27 :
Jika λc ≤ 0,25 maka ὠ = 1
Jika 0,25 ˂ λc ˂ 1,2 maka ὠ = 1,43/(1,6-0,67 λc)
Jika λc ≥ 1,2 maka ὠ =〖1,25⁡𝜆� 〗^2

ὠx =〖1,25⁡𝜆� 〗^2
= 4.26

ὠy = 1,43/(1,6-0,67 λc)
1.14

Nnx = Ag x (fy/ὠx)
= 327936.65

Nny = Ag x (fy/ὠy)
= 1221748.35

Digunakan Nn minimum = 327936.65


327.94
SNI 03-1729-2002 hal 24 :
ɸNn = 278.75

(Nu/ɸNn) ˂ 1
= 0.15

OK

Efek Balok :
Menentukan konstanta-konstanta untuk profil WF simetris:
h1 = tf + r
= 21

h2 = ht - 2(h1)
= 152
h = ht - tf
= 185

tf = H - (2 x t2)
= 176

J = ∑〖� 〖
� ^3〗/ 3
= 85572

lw = (ly xℎ^2) / 4
= 43380187500

Zx = (b x tf) (h - tf) + tw(0,5h - tf) (0,5h - tf)


= 296214

X1 = phi/Zx
= 17276.30

lw =
= 39262080000

X2 = 4
= 0.00006

Menentukan kuat nominal lentur penampang dengan pengaruh tekuk lokal.


Kontrol penampang termasuk kompak, tidak kompak atau langsing

Untuk tekuk lokal pelat sayap:

λ = bf/2tf
= 8.33

λp = 170 /
= 8.96

λr = 370 /
= 21.73

Karena λ < λp, maka penampang Kompak

Untuk tekuk lokal pelat badan:

λ = (h-2tf)/tw
= 29.33
λp = 1680 /
= 88.54

λr = 2550 /
= 134.40

Karena λ < λp, maka penampang Kompak

Menentukan batasan momen plastis, Mp:

Mp = Zx fy
= 106637040
= 106.64

Mr = Sx (fy - fr)
= 85902060
= 85.90

SNI 03-1729-2002 hal 36 :


Maka, Mn = Mp
= 106637040
= 106.64

Menentukan kuat nominal lentur penampang dengan pengaruh tekuk lateral kontrol penampang, termas

Panjang Lb = jarak pengaku/sokongan lateral = Ly

fl = fy-fr
= 290

Lb = Ly
= 1415.71
= 1.42

Lp = 1,76 ry
= 1522.45
= 1.52

Lr = ry
= 4045.82
= 4.05

Karena Lb< Lp termasuk bentang pendek, kuat nominal komponen struktur terhadap momen lentur ada
Mn = Mp
= 106.64
=

Momen nominal diambil yang paling menentukan =

Menentukan faktor perbesaran momen:


Momen lentur terhadap sumbu x
Ditinjau untuk kondisi portal tak bergoyang (braced):

SNI 03-1729-2002 hal 27 :


√(𝑓�/𝐸)
λc = 1/phi x Lk/r
= 1.116

(𝐴𝑏⁡𝑓�)/(λ_�^2⁡)
Ncrb =
= 1121860.43

βm = M1x/M2x
= 0.41

SNI 03-1729-2002 hal 23 :


Cmx = 0,6 - 0,4 βm ≤ 1
= 0.43

δbx = (Cmx/(1-(Nu/Ncrb)) ≥ 1
= 0.45
Diambil = 1

Menentukan momen ultimate (Mu) :


SNI 03-1729-2002 hal 22 :
Mux = δbx Mntux + δbx Mltux
= 142

Nu/ɸNn = 0.148
Nu/2ɸNn = 0.070

SNI 03-1729-2002 hal 24 :


(�𝑢𝑥/(ɸ𝑏⁡��𝑥)+⁡ ���/(ɸ� ���))⁡
Bila Nu/ɸNn < 0,2 maka = Nu/2ɸNn +
Interaksi Aksial & Momen = 0.9

Kontrol kuat geser nominal tanpa pengaku:


Ketebalan minimun pelat badan tanpa adanya pengaku:

ℎ2/𝑡� ≤ 6,36 √(𝐸/𝑓�)

h2/tw = 25.33

6,36 √(𝐸/𝑓�) = 1766.67

Kuat geser pelat badan tanpa adanya pengaku:

Aw = tw x ht
= 1164

Vn = 0,6 fy Aw
= 251424

SNI 03-1729-2002 hal 45 : SNI 03-1729-2002 hal 18


Vu/ɸVn < 1
= 0.13

#Kesimpulan : Profil IWF 300X150X6,5X9 memenuhi persyaratan (Aman)


Mpa
Mpa
Mpa
Mpa (untuk penampang di rol) SNI 03-1729-2002 hal 31

kNm 35587500 Nmm Label M (kNm)


kN 28733 N 947 35.5875
kN 41235 N 947 14.7014
kN 14701400 Nmm MA = 35.3784
kNm 35587500 Nmm MB = 35.1693
kNm 35378400 Nmm MC = 34.7879
kNm 35169300 Nmm
kNm 34787900 Nmm
mm Label Vu (kN)
mm 952 28.733

mm
mm

Jika λc ≥ 1,2 maka ὠ =〖1,25⁡𝜆� 〗^2


pake itu

N
kN

N untuk komponen struktur tekan = 0,85


untuk komponen struktur tarik=0,9

˂1

Label Nu (kN)
250 41.235

mm

mm
mm

mm

mm

mm6

w(0,5h - tf) (0,5h - tf)


mm3

Nmm

mm6

N/mm2

aruh tekuk lokal.


Nmm
kNm

Nmm
kNm

Nmm
kNm

aruh tekuk lateral kontrol penampang, termasuk bentang pendek, menengah atau panjang

Mpa

mm
m

mm
m

mm
m

omponen struktur terhadap momen lentur adalah:


kNm

106.64 kNm

SNI 03-1729-2002 hal 32:

Lk = kc L
= 0.990997 m
= 990.997 mm

tanya doni bagaimana?

mltux nya belum dimasukin kerjaannya <==


kNm gatau bener atau salah (30-8-16)

��𝑥)+⁡ ���/(ɸ� ���))⁡


< 1,0 M2 label 947 (kNm)
0.8506 <== Muy

< 1,0

Mny = Fy x Zy / 12
= 2028000
= 2.03

mm2

ersyaratan (Aman)
MU

L (m)
1.41571
1.41571
0.3539275
0.707855
1.0617825

L (m)
0.11439
NU

L (m)
0.10785
Tidak dipakai?
850600 Nmm

Nmm
kNm
VU
7.    Perencanaan Sambungan Angkur

a.
Gaya gaya pada Rafter
1 Rafter:
Gaya Aksial (Nu) = 18.81 kN
Gaya Geser (Vu) = 14.983 kN

Gaya reaksi tumpuan vertikal (Pv) = 48.526 kN


Gaya reaksi tumpuan horizontal (Ph) = 54.865 kN

2 Rafter:

Gaya reaksi tumpuan vertikal (Pv) = 102.344 kN


Gaya reaksi tumpuan horizontal (Ph) = 7.865 kN

1 Rafter:
Data Plat (Baseplat) :
Lebar Plat, b = 250 mm
Panjang Plat, a = 496.01 mm
Tebal Plat, t = 24 mm

b.
Kontrol Tegangan yang Timbul
1 Rafter:
σbeton = σbaseplate

σbeton =��/(𝐿⁡𝑥⁡𝐵)

σbeton = 0.39

check = σb x L x Beff > Pv


= 48623 N
Pv = 48526 N
OK

𝑡/� ≤ 0.63

𝑡/� ≥ 0.63
t = tebal base plate
d = diameter baut

𝑡/� = 2.00 ≥

Baut diperhitungkan terhadap geser

2 Rafter:
σbeton = σbaseplate

σbeton =��/(𝐿⁡𝑥⁡𝐵)

= 0.70

check = σb x L x Beff > Pv


= 102468 N
Pv = 102344 N
OK

𝑡/� ≤ 0.63

𝑡/� ≥ 0.63

t = tebal base plate


d = diameter baut

𝑡/� = 2.00 ≥

Baut diperhitungkan terhadap geser

c.
Geser Angkur Pada Baseplate
Digunakan baut dengan spesifikasi sebagai berikut:
Kuat Tarik (fub) = 340 Mpa
Diameter Angkur (dn) = 12 mm
Faktor Reduksi Baut (∅) = 0.75 (Dasar T Pudin)
Bidang Geser (m) = 1 (Dasar T Pudin)
Bidang Geser Baut tak berulir (r1) = 0.5 (Dasar T Pudin)
d.
Penentuan Jumlah Angkur
1Rafter
SNI 03-1729-2002 hal 100 :
Kekuatan Nominal Baut (Vd) = ɸ f �_�
= ɸ𝑟_1⁡⁡𝑓_𝑢^𝑏
f m 𝐴_𝑏
= 14412.60 N

Geser Baut Ref gable


Vu ˂ n Vd
14983 ˂ 57650 N
n= 4 buah

e.
Menentukan Jarak Antar Baut/Angkur:

Jarak Antar Baut: 1 Rafter


3db < S < 15tp
3db = 36 mm
15tp = 360 mm
S= mm

1.5 db < S1 < (4tp+100mm)


1.5db = 18 mm
4tp+100mm = 196 mm
S1 = mm

Jarak baut tepi dengan ujung pelat (S1) = mm


Jarak antar pusat lubang baut (S) / (a) = mm

2 Rafter

3db < S < 15tp


3db = 48 mm
15tp = 360 mm
S= mm

1.5 db < S1 < (4tp+100mm)


1.5db = 24 mm
4tp+100mm = 196 mm
S1 = mm

Jarak baut tepi dengan ujung pelat (S1) = mm


Jarak antar pusat lubang baut (S) / (a) = mm

f.
Menentukan Jumlah Baut Angkur:
18810 N
14983 N Label Vu (kN) L (m)
944 14.983 1.41571
48526 N
54865 N

Label Nu (kN) L (m)


944 18.81 1.41571

102344 N
7865 N

2 Rafter:
mm Lebar Plat, b =
mm Panjang Plat, a =
mm Tebal Plat, t =

Label Pv (kN)
1 48.526

digunakan panjang plat 497 mm

�𝑢/𝑅�
maka Baut diperhitungkan terhadap Tumpu

�𝑢/��
maka Baut diperhitungkan terhadap Geser
0.63

ungkan terhadap geser

digunakan panjang plat 587 mm

�𝑢/𝑅�
maka Baut diperhitungkan terhadap Tumpu

�𝑢/��
maka Baut diperhitungkan terhadap Geser

0.63

ungkan terhadap geser

1Rafter
Mpa Kuat Tarik (fub) = 340
mm Diameter Angkur (dn) = 16
(Dasar T Pudin) Faktor Reduksi Baut (∅) = 0.75
(Dasar T Pudin) Bidang Geser (m) = 1
(Dasar T Pudin) Bidang Geser Baut tak berulir (r1) = 0.5
r1 = 0.5
ɸ = 0.75

atau Ref perhitungan base anchor


�/�
˂ Vd
�/�
buah = 13716.25 N

Vd = 14412.60 N
OK

mm
mm
mm

< (4tp+100mm)
mm
mm
mm

mm
mm

Chemical Anchor Merek HILTI

mm
mm
mm

< (4tp+100mm)
mm
mm
mm

mm
mm
250 mm
586.29 mm
24 mm

Ph (kN)
54.865
2 Rafter
Mpa
mm
(Dasar T Pudin)
(Dasar T Pudin)
(Dasar T Pudin)
2 Rafter

Kekuatan Nominal Baut (Vd) = ɸ f �_�


= ɸ𝑟_1⁡⁡𝑓_𝑢^𝑏
f m 𝐴_𝑏
= 25622.40 N

Ref perhitungan base anchor


�/�
˂ Vd
�/�
= 1966.25 N

Vd = 25622.40 N
OK

Sumber
(Slide-TSP306-Perancangan-Struktur-Baja-TSP-306-P12)

Merek HILTI
Jumlah Baut Angkur Base plate Tiap Batang Rafter (1 Rafter)
No RafterJumlah Baut Angkur Rencana
Gaya Tumpuan
(nb) (Ph) Gaya Pikul Baut (Vd)
Atap Model 1 Segmen 1 Buah kN kN
R1 (Kiri) 4 54.865 14.41
R2 (Kiri) 4 52.464 14.41
R3 (Kiri) 4 49.777 14.41
R4 (Kiri) 4 41.807 14.41
R5 (Kiri) 4 33.562 14.41
R6 (Kiri) 4 23.596 14.41
R7 (Kiri) 4 6.298 14.41
R8 (Kiri) 4 25.848 14.41

Keterangan:
�/�
˂ Vd
Jumlah Baut Angkur Base plate Tiap Batang Rafter (2 Rafter)
No RafterJumlah Baut Angkur Rencana
Gaya Tumpuan
(nb) (Ph) Gaya Pikul Baut (Vd)
Atap Model 1 Segmen 1 Buah Kn Kn
R1 (Kanan) 4 7.865 25.62
R2 (Kanan) 4 99.585 25.62
R3 (Kanan) 4 53.944 25.62
R4 (Kanan) 4 23.818 25.62
R5 (Kanan) 4 4.295 25.62
R6 (Kanan) 4 14.138 25.62
R7 (Kanan) 4 38.357 25.62
R8 (Kanan) 4 72.52 25.62

Keterangan:
�/�
˂ Vd
Vu

Pv yang diambil ini?


Chemical Anchor Merek HILTI
atang Rafter (1 Rafter)
Ph /nb n x Vd
Status
kN kN
13.71625 57.6504 OK
13.116 57.6504 OK
12.44425 57.6504 OK
10.45175 57.6504 OK
8.3905 57.6504 OK
5.899 57.6504 OK
1.5745 57.6504 OK
6.462 57.6504 OK
atang Rafter (2 Rafter)
Ph /nb n x Vd
Status
Kn Kn
1.96625 102.4896 OK
24.89625 102.4896 OK
13.486 102.4896 OK
5.9545 102.4896 OK
1.07375 102.4896 OK
3.5345 102.4896 OK
9.58925 102.4896 OK
18.13 102.4896 OK
Nu
9.    Perencanaan Sambungan Las

Sambungan rafter puncak dirancang dengan menggunakan sambungan baut dan las.

Sambungan ini termasuk sambungan las yang menahan geser lentur

a.
Beban Rencana:

Lintang Rafter (Vu) = Nu = 27.859 kN R1


27859 N

Momen Rafter (Mu) = 13.8555 kNm R1


13855500 Nmm

b.
Data Plat Sambungan Rafter:

Lebar plat (b) = 0 mm


Tinggi Plat (h) = 220 mm
Tebal Plat (tp) = 0 mm

b.
Menentukan Tebal Las:

Tebal las = ½ x t √2

t = Tebal pelat minimum

Diambil tebal pelat minimun = tebal pelat


Diambil tebal pelat minimun = 0 mm

Tebal las = ½ x t √2
= 0.00 mm ≈

Dengan bantuan software Auto CAD 2012, didapatkan luas area bidang las (command : MASSP

a =
b =
c =
d =

Luas Area Las (A las):


A las = a+b+c+d
= 9480.00 mm2

c.
Menentukan Letak Garis Netral:

Tinggi bidang las (h) = h + 2(t)


= 240.00 mm

Lebar las terkecil (δ) = tw + 2(t)


= 20.00 mm

Lebar las terbesar (b) = b + 2(t)


= 20.00 mm

Lebar efektif las (b') = 0.75 x b


= 15.00 mm

Diasumsikan garis netral terletak pada jarak x dari sisi atas las

Momen statis luasan terhadap garis netral


1/2 x b' (h-x)2 = 1/2 x δ x x2
(b'-δ) / 2 x x2 - b' x h x x + 1/2 x b' x h2 = 0
=
Ax (b'-δ)/2
= -2.50

Bx = (-b') x h
= -3600.00

Cx = 1/2 x b' h2
= 432000

Dx = Bx2 -(4 x Ax x Cx)


= 17280000
= 17280000

(−𝐵𝑥−√𝐷𝑥)/2𝐴𝑥
x=

= 111.38 mm

Ix =
Ix = {(1/12 X b x h3)

Momen Inersia arah x (Ix) = 25845988 mm4

Besar tegangan kritis pada las:

Akibat beban langsung (Vu):


τp =

= 2.94 MPa

Akibat momen (Mu):


Titik las terjauh ke titik berat pola las (y) = 111.38 mm

τx =

= 59.71 MPa

Besarnya tegangan krisis las:


τ=
= 60 MPa

fuw = tegangan ijin las


= 0,75 fu

Elektroda yang digunakan E20.1.3


fu = 20 ksi
= 20000 x

= 1407.40 kg/cm2
140.74 N/mm2

fuw = 0,75 fu
= 105.56 N/mm2

Syarat kekuatan las: τ ≤ fuw

τ= 60 Mpa
fuw = 105.56 Mpa
OK

sambungan bawah bukan pada baseplate angkur


Sambungan bawah dirancang dengan menggunakan sambungan las. Tinjauan dilakukan pada yang kritis ya

Sambungan ini termasuk sambungan las yang menahan geser lentur

a.
Beban Rencana:

Lintang Rafter (Vu) = 18.759 kN


18759 N

Momen Rafter (Mu) = 35.282979 kNm


35282979 Nmm

b.
Data Plat Sambungan Rafter:

Lebar Profil (b) = 150 mm


Tinggi Profil (h) = 93 mm
Tebal Plat (tp) = 12 mm

b.
Menentukan Tebal Las:

Tebal las = ½ x t √2

t = Tebal pelat minimum

Diambil tebal pelat minimun = Tebal Plat


Diambil tebal pelat minimun = 12 mm
Tebal las = ½ x t √2
= 8.49 mm ≈

Dengan bantuan software Auto CAD 2012, didapatkan luas area bidang las (command : MASSP

a =
b =
c =
d =

Luas Area Las (A las):


A las = a+b+c+d
= 4795 mm2

c.
Menentukan Letak Garis Netral:

Tinggi bidang las (h) = h + 2(t)


= 113 mm

Lebar las terkecil (δ) = tp + 2(t)


= 32 mm

Lebar las terbesar (b) = b + 2(t)


= 170 mm

Lebar efektif las (b') = 0.75 x b


= 127.50 mm

Diasumsikan garis netral terletak pada jarak x dari sisi atas las

Momen statis luasan terhadap garis netral


1/2 x b' (h-x)2 = 1/2 x δ x x2
(b'-δ) / 2 x x2 - b' x h x x + 1/2 x b' x h2 = 0
Ax = (b'-δ)/2
= 47.75

Bx = (-b') x h
= -14407.50

Cx = 1/2 x b' h2
= 814024

Dx = Bx2 -(4 x Ax x Cx)


= 52097520
= 52097520

(−𝐵𝑥−√𝐷𝑥)/2𝐴𝑥
x=

= 75.28 mm

Ix =

Ix = {(1/12 X b x h3)

Momen Inersia arah x (Ix) = 25845988 mm4

Besar tegangan kritis pada las:

Akibat beban langsung (Vu):


τp =

= 3.91 MPa

Akibat momen (Mu):


Titik las terjauh ke titik berat pola las (y) = 75.28 mm

τx =

= 102.77 MPa

Besarnya tegangan krisis las:


τ=
= 103 MPa

fuw = tegangan ijin las


= 0,75 fu

Elektroda yang digunakan E30.1.3


fu = 30 ksi
= 30000 x

= 2111.10 kg/cm2
211.11 N/mm2

fuw = 0,75 fu
= 158.33 N/mm2

Syarat kekuatan las: τ ≤ fuw

τ= 103 Mpa
fuw = 158.33 Mpa

OK

Sambungan bawah (baseplate angkur) dirancang dengan menggunakan sambungan las dan baut. Yang ditin

Sambungan ini termasuk sambungan las yang menahan geser lentur

a.
Beban Rencana:

Lintang Rafter (Vu) = 18.759 kN


18759 N

Momen Rafter (Mu) = 35.282979 kNm


35282979 Nmm

b.
Data profil Sambungan Rafter:
Pelat bukan Plat
Lebar profil (b) = 150 mm
Tinggi profil (h) = 504 mm
Tebal pelat (tp) = 12 mm
b.
Menentukan Tebal Las:

Tebal las = ½ x t √2

t = Tebal pelat minimum

Diambil tebal pelat minimun = Tebal Plat


Diambil tebal pelat minimun = 12 mm

Tebal las = ½ x t √2
= 8.49 mm ≈

Dengan bantuan software Auto CAD 2012, didapatkan luas area bidang las (command : MASSP

a =
b =
c =
d =

Luas Area Las (A las):


A las = a+b+c+d
= 15540 mm2

c.
Menentukan Letak Garis Netral:

Tinggi bidang las (h) = h + 2(t)


= 524 mm

Lebar las terkecil (δ) = tm + 2(t)


= 32 mm

Lebar las terbesar (b) = b + 2(t)


= 170 mm

Lebar efektif las (b') = 0.75 x b


= 127.50 mm

Diasumsikan garis netral terletak pada jarak x dari sisi atas las

Momen statis luasan terhadap garis netral


1/2 x b' (h-x)2 = 1/2 x δ x x2
(b'-δ) / 2 x x2 - b' x h x x + 1/2 x b' x h2 = 0
Ax = (b'-δ)/2
= 47.75

Bx = (-b') x h
= -66810.00

Cx = 1/2 x b' h2
= 17504220

Dx = Bx2 -(4 x Ax x Cx)


= 1120270080
= 1120270080

(−𝐵𝑥−√𝐷𝑥)/2𝐴𝑥
x=

= 349.11 mm

Ix =

Ix = {(1/12 X b x h3)

Momen Inersia arah x (Ix) = 25845988 mm4

Besar tegangan kritis pada las:

Akibat beban langsung (Vu):


τp =

= 1.21 MPa

Akibat momen (Mu):


Titik las terjauh ke titik berat pola las (y) = 349.11 mm

τx =

= 476.57 MPa

Besarnya tegangan krisis las:


τ=
= 477 MPa

fuw = tegangan ijin las


= 0,75 fu

Elektroda yang digunakan E30.1.3


fu = 100 ksi
= 100000 x

= 7037.01 kg/cm2
703.70 N/mm2

fuw = 0,75 fu
= 527.78 N/mm2

Syarat kekuatan las: τ ≤ fuw

τ= 477 Mpa
fuw = 527.78 Mpa

OK
R1

R1

(Tebal Pelat/ Tebal Web / Tebal Flens) BAB IV AGUS

10.0 mm

las (command : MASSPROP).

(4.2 x 17.4) x 4
(4.2 x 150) x 2
(4.2 x 67.55) x 4
(4.2 x 193.32) x 2
dari SAP

check ada tidak elektroda 20 ksi?


kukan pada yang kritis yaitu sambungan 2 Rafter

Vu = Vu tidak diganti Nu

(Tebal Pelat/ Tebal Web / Tebal Flens) BAB IV AGUS


10.0 mm

las (command : MASSPROP).

(10 x 25) x 2
(10 x 150) x 1
(10 x 78) x 2
(10 x 61,75) x 2
dari SAP
check ada tidak elektroda 30 ksi?

n las dan baut. Yang ditinjau yang kritis yaitu sambungan 2 Rafter

Vu = Vu tidak diganti Nu
(Tebal Pelat/ Tebal Web / Tebal Flens) BAB IV AGUS

10.0 mm

las (command : MASSPROP).

h tinggi bidang las


b lebar bidang las

dari SAP
check ada tidak elektroda 30 ksi?
8.    Perencanaan Sambungan Rafter Puncak (Atas)

RAFTER PUNCAK

Eksentris karena tidak direlease

Data:
Mutu profil baja
Mutu pelat baja
Tebal pelat (tp)
Mutu baut
Diameter baut (dn)
Kuat tarik baut (fub)
Bidang geser (m)

Eksentris karena tidak direlease

Lebar pelat, b
Lebar efektif pelat sambung bagian tekan (b’):
b'

Diameter Baut (dn)

Beban rencana:
Mu

Vu

d.
Menentukan Jarak Antar Baut:
Jarak Antar Baut:

3db
15tp
1.5db
4tp+100mm

Jarak baut tepi dengan ujung pelat (S1) (a')


Jarak antar pusat lubang baut (S) / (a)

Pudin 29-7-16
Letak garis Netral:
jumlah baut total
n

nx
ny

a
a'

Tinggi Pelat (h)

Diasumsikan garis netral terletak pada jarak x dari sisi atas pelat sambung

1/2 x b' (h-x)2


(b'-δ) / 2 x x2 - b' x h x x + 1/2 x b' x h2
Ax
Bx

Cx

Dx

Tegangan yang terjadi pada baut

Persamaan hubungan tegangan baut


σ3

σ2

Persamaan momen terhadap titik netral:

½ x (h – x) x b’ x σ3 x 2/3 x (h – x) + ½ x x x δ x σ1 x 2/3 x x
Substitusi persamaan (1) sehingga:
½ x (h – x) x b’ x σ1 x 2/3 x (h – x) + ½ x x x δ x σ1 x 2/3 x x

Sehingga diperoleh
(3⁡𝑥⁡�𝑢)/([((ℎ−
σ1

Tegangan pada masing-masing baris baut dihitung sebagai berikut:


(Tegangan tarik pada sisi atas pelat sambung (1):
dari persamaan (3)
σ1

(Tegangan tekan pada sisi bawah pelat sambung (3):


dari persamaan (1)
σ3
(Tegangan tarik pada baut baris teratas (2):
dari persamaan (2)
σ2

Tegangan tarik putu pada baut dan pelat:


Tegangan tarik putus baut (fub)
Tegangan tarikputus pelat (fup)

Gaya Tarik Pada Baut:

Gaya tarik yang terjadi pada baut baris teratas (Tu):

Tu

Gaya tarik yang ditahan oleh satu buah baut (Tu1):

Tu1

Luas Penampang Baut (Ab):

Ab

Luas tarik nominal baut (Tn):


Tn

Tahanan tarik satu baut:

Syarat yang harus dipenuhi:

Tu1
∅t x Tn

j.
Gaya Geser Pada Baut:

Gaya geser yang ditahan oleh salah satu baut (Vs1):


Vs1

Tahanan geser nominal baut (Vn):

Vn

Tahanan geser satu baut:

∅f x Vn

Syarat yang harus dipenuhi:

Vs1
∅f x Vn

k.
Gaya Tumpu Pada Baut:

Gaya tumpu yang ditahan oleh salah satu buat (Rs1):

Rs1

Tahanan geser nominal baut (Rn):

Rn

Tahanan tumpu satu baut

∅f x Rn

Syarat yang harus dipenuhi:

Rs1
∅f x Rn

l.
Kombinasi Antara Geser dan Tarik:
Konstanta tegangan (f1) untuk A490
Konstanta tegangan, (f2) untuk A490
Faktor geser pengaruh ulir pada bidang geser (r1)
Faktor tegangan pengaruh ulir pada bidang geser, (r2)

Tegangan geser yang terjadi (fuv)

fuv

Tahanan geser baut

Syarat yang harus dipenuhi:

fuv
∅f x r1 x m x fub

Gaya tarik yang terjadi (Tu1):


Tahanan tarik baut:
∅t x Tn

Syarat yang harus dipenuhi:

Tu1
∅t x Tn

Tegangan tarik (ft)

Nilai tegangan kombinasi (f1 – r2×fuv)

Syarat yang harus dipenuhi:

ft
f1 - r2 x fuv
ft
f2
= BJ - 44 (fy = 280 MPa ; fu = 440 MPa)
= BJ - 44 (fy = 280 MPa ; fu = 440 MPa)
= 12 mm
= A-490 (ulir penuh)
= 25.4 mm 1"
= 1035 MPa
= 1

= 150 mm isi

= 0.75 x b
= 112.5 mm

= 25.4 mm

= 13.8555 kNm dibawa yg sebelah kanan (jadi yang max)


13855500 Nmm

= 48.611 kN dibawa yang sebelah kiri (jadi yg max)


48611 N

3db < S < 15tp


= 76.2 mm SNI 03-1729-2002 Hal 104:
= 180 mm
1.5 db < S1 < (4tp+100mm)
= 38.1 mm
= 148 mm

= 60 mm
= 100 mm

= nx x ny
= 4 bh

= 2
= 2

= 100 mm S
= 60 mm S1

= 2 x S1 + 1 x s
= 220 mm Tanya Pudin bener ga

= 10.13 mm

= 1/2 x δ x x2
= 0
= (b'-δ)/2
= 51.19

= (-b') x h
= -24750

= 1/2 x b' h2
= 2722500

= Bx2 -(4 x Ax x Cx)


= 55152470.34
= 55152470.34

(−𝐵𝑥−√𝐷𝑥)/2𝐴𝑥
=

= 169.22 mm

=((ℎ−𝑥))/𝑥 σ1 persamaan (1)

((𝑥−(𝑎′))/𝑥 σ1
= persamaan (2)

2𝐴𝑏/�

= Mu

= Mu

(3⁡𝑥⁡�𝑢)/([((ℎ−𝑥)^3)/𝑥⁡𝑥𝑏^′+𝑥^2⁡𝑥𝛿])
= persamaan (3)

= 110.23 MPa

= 33.08 MPa
= 71.15 MPa
(−𝐵𝑥−√𝐷𝑥)/2𝐴𝑥

= 1035 MPa
= 440 MPa

= σ2 x a x δ
= 72063.62 N

= Tu/nx
= 36031.81 N

= x π x dn 2
= 506.45 mm2

= 0.75 x Ab x fub
= 393132.28
= 393132.28 N

= ∅t x Tn
= 294849.21 N

Tu1 ≤ ∅t Tn
= 36031.81 N
= 294849.21 N
AMAN (OK)
= Vu/n Faktor pengaruh ulir pada bidang geser:
= 12152.8 N r1 = 0.4

= r1 x m x Ab x fub
= 209670.55 N

= 0.75 x Vn
= 157252.91 N

Vs1 ≤ ∅f Vn
= 12152.8 N
= 157252.91 N
AMAN (OK)

= Vs1
= 12152.8 N

= 3.2 x dn x tp x fup
= 429158.4 N

= 0.75 x Rn
= 321868.8 N

Rs1 ≤ ∅f Rn
= 12152.8 N
= 321868.8 N
AMAN (OK)
= 1010 MPa tanya Pudin
= 779 MPa
= 0.4
= 1.9

�𝑢/(�⁡𝑥⁡𝐴𝑏)
=
= 24.00 MPa

= ∅f x r1 x m x fub
= 310.5 MPa

fuv ≤ ∅f x r1 x m x fub
= 24.00 MPa
= 310.5 MPa
AMAN (OK)

= 36031.81 N

= ∅t x f1 x Ab
= 383636.33 N

Tu1 ≤ ∅t x Tn
= 36031.81 N
= 383636.33 N
AMAN (OK)

= 0.75 x fub
= 776.25 MPa

= f1 – r2×fuv
= 964.41 MPa

ft ≤ f1 - r2 x fuv
= 776.25 MPa
= 964.41 MPa
AMAN (OK)
ft ≤ f2
= 776.25 MPa
= 779 MPa
AMAN (OK)
Sumber
(Slide-TSP306-Perancangan-Struktur-Baja-TSP-306-P12)

contoh
9.    Perencanaan Talang Air Hujan

a.
Standar Perencanaan:
SNI 03- 6481-2000 Sistem Plambing

Unit beban alat plambing maksimum yang diizinkan untuk alat plambing yang dapat
dihubungkan pada tiap pipa cabang datar alat plambing, pipa tegak air kotoran, pipa tegak
air kotor, saluran pembuangan gedung dan juga cabang saluran pembuangan gedung dan
pipa tegak harus ditentukan dari tabel 7.32.1, kecuali bila ditentukan lain.

b.
Curah Hujan Daerah:

Curah hujan di suatu tempat antara lain dipengaruhi oleh keadaan iklim,
geografis dan perputaran/pertemuan arus udara. Pada tahun 2010 Kabupaten
Majalengka diguyur hujan setiap bulannya dengan curah hujan tertinggi terjadi
pada bulan Maret 2010 yang mencapai 586 mm dengan jumlah hari hujan
mencapai 22 hari, dan terendah pada bulan Juli yaitu 89 mm dengan jumlah hari

hujan sebanyak 17.


Curah hujan tahunan rata-rata di Kabupaten Majalengka berkisar antara 2.400 mm-3.800 mm/tahun.
dengan rata-rata hari hujan sebanyak 11 hari/bulan.

Curah Hujan Majalengka (Ch):


=
diambil =

Rata-rata Curah Hujan 2010 =


Rata-rata Curah Hujan 2013 =
Rata-rata Curah Hujan 2014 =

Rata-rata curah hujan =


diambil =

Curah hujan rata-rata Indonesia =

c.
Penjelasan Talang Air Hujan:

Talang yang dipasang pada bangunan terdapat dua macam yaitu:


Talang luar
Talang luar adalah talang yang berfungsi untuk mengalirkan air dari
cucuran atap yang dapat dilihat langsung.

Talang dalam
Talang dalam adalah talang yang berfungsi untuk mengalirkan air dari
cucuran atap yang tidak dapat dilihat langsung karena tertutup oleh
lisplang.

Talang yang dipakai untuk mengalirkan air dari atap gedung dapat bermacam-macam bentuknya. Umumny
1 Nominal Half Round ( tembereng ),
2 Deep Half Round ( setengah lingkaran dalam ),
3 Box/ rectangular ( segi empat )
4 True Half Round ( setengah lingkaran )
5 Ogee
6 IndustrialTrapesoidal ( trapesium)

Jenis Bahan Talang


Zincalume

Bentuk Penggantung Talang


Konstruksi yang p
Jarak perkuatan ta
1 Penggantung/ kait
Besi
2 Papan Talang

d.
Data Rencana Talang Penutup Atap:

Ukuran atap zincalume:


1 Talang ( Gutter )

2 Bok Talang ( Box Gutter)

3 Pipa Tegak ( Rainwater Pipe )

4 Bak Buangan Air Hujan ( Back Inlet Gully )

e.
Analisis Talang:

Luas atap:
Ra =
=
=
=

Overstek atap (Os) =


=
Besarnya debit aliran air dari atap adalah:
(𝐶ℎ⁡𝑥⁡𝑅𝑎)/(3600⁡𝑥⁡10
Q =

Kecepatan aliran:

Kecepatan aliran air dari talang ke pipa tegak:

V =
=
Sistem Plambing
mm-3.800 mm/tahun.

200-300 mm/bln
250 mm/bln

264.75 mm/bln
233.42 mm/bln
206 mm/bln

234.72 mm/bln
250 mm/bln

5 sd 8 Liter/menit

cam bentuknya. Umumnya yang biasa digunakan terdapat enam bentuk antara lain:
Konstruksi yang paling sederhana ialah talang diletakan di atas penggantung yang dibuat dari kait besi atau PVC yang dig
Jarak perkuatan talang arah membujur /searah aliran air dapat dibuat 100 cm atau dua kasau/usuk satu perkuatan talang.

Flashing
CONTOH TALANG AIR/GUTTER DAN B

P x L cos (Sudut Atap)° P =


(P + Os) x (L+Os) x cos (Sudut Atap)° =
31952142808.2826 mm2
31952142.8082826 m2 L =
=

0.2 m
200 mm
(𝐶ℎ⁡𝑥⁡𝑅𝑎)/(3600⁡𝑥⁡1000" "⁡)

2218.90 m3

√2��
(2/3)
SNI 03- 6481-2000

Curah Hujan Majalengka 2010

Kelembaban
Tekanan Udara Nisbi Penyinaran Curah Hujan
Bulan (mb) Matahari (%) (mm)
(%)

Januari 1011.5 86 43 391


Februari 1011.4 85 56 315
Maret 1011.2 85 60 586
April 1010.8 83 64 409
Mei 1009.9 82 60 90
Juni 1010.9 83 51 181
Juli 1010.8 80 52 89
Agustus 1011,1 77 70 115
September 1010.9 81 52 216
Oktober 1010.1 78 54 197
November 1009.6 82 48 314
Desember 1007.9 84 39 274

Sumber : BMKG, Stasiun Meteorologi Jatiwangi


dibuat dari kait besi atau PVC yang digantungkan pada papan cucuran dengan jarak 1,00 meter atau setiap dua kasau satu pengga
ua kasau/usuk satu perkuatan talang.
TOH TALANG AIR/GUTTER DAN BOX GUTTER

Panjang bangunan untuk atap model 1 ATAU 1 SEGMEN?


900000 mm

Lebar bangunan untuk atap model 1


40000 mm
Curah Hujan Majalengka 2013

Tekanan Udara, Kelembaban dan Curah Hujan Setiap Bulan


di Kabupaten Majalengka Tahun 2013

Kelembaban
Hari Hujan Bulan Tekanan Udara (mb) Nisbi
(%)

29 Januari 1003.8 86
23 Februari 1002.8 85
22 Maret 1004.2 85
20 April 1003.2 84
14 Mei 1003.5 82
15 Juni 1002.7 84
17 Juli 1004 83
18 Agustus 1004.7 70
21 September 1004.6 66
21 Oktober 1004.9 67
22 November 1002.9 77
23 Desember 1001.9 86

Sumber : BMKG, Stasiun Meteorologi Jatiwangi


ap dua kasau satu penggantung.

Nok dan Talang


n dan Curah Hujan Setiap Bulan Tekanan Udara, Kelem
jalengka Tahun 2013 di Kabupate
Atmospheric Pressure, Humidity

Penyinaran Curah Hujan Hari Hujan


Matahari (%) (mm)
Bulan
Month

37 341 26
53 413 19 Januari
61 403 20 January

61 310 14 Februari
63 157 16 February

58 222 14 Maret
61 205 14 March

88 20 1 April
93 0 1 April

82 40 9 Mei
50 138 18 May

45 552 28 Juni
June

Juli
July

Agustus
August

September
September

Oktober
October

November
November

Desember
December

Sumber : BMKG, Stasiun Meteorologi Jatiwangi


Source : BMKG, Jatiwangi Meteorological Station.
Curah Hujan Majalengka 2014

Tekanan Udara, Kelembaban dan Curah Hujan Setiap Bulan


di Kabupaten Majalengka Tahun 2014
Atmospheric Pressure, Humidity and Rainfalls Every Month in Majalengka, 2014

Tekanan Udara Kelembaban Nisbi Penyinaran Matahari Curah Hujan Hari Hujan
Pressuri-zations Relative Humidity Solar Irradiations (%) Rainfalls (mm) Rainy Day

(mb) (%)

1012.2 90 28 592 29
1012.2 90 28 592 29

1011.3 89 33 343 22

1011.8 84 66 223 21

1011.6 84 69 300 21

1011.5 82 75 196 17

1011.1 82 60 54 10

1014.1 78 61 62 10

1016.4 71 85 9 1

1016.5 62 94 0 1

1015.7 62 79 18 4

1014.9 75 54 233 15

1014.5 84 43 442 24

teorologi Jatiwangi
eorological Station.

You might also like