Catalog ST 70 · 2005
Automation and Micro Automation
Products for Totally Integrated
simatic
The information provided in this catalog contains descriptions
or characteristics of performance which in case of actual use
do not always apply as described or which may change as a
result of further development of the products. An obligation
to provide the respective characteristics shall only exist if
expressly agreed in the terms of contract. Availability and
technical specifications are subject to change without notice.
s
Siemens AG
s
Automation and Drives
Industrial Automation Systems
Postfach 4848
Products for
90437 NÜRNBERG
FEDERAL REPUBLIC OF GERMANY
Totally Integrated Automation
www.siemens.com/automation Order No.: E86060-K4670-A111-A9-7600 and Micro Automation
Related catalogs
SIMATIC ST 50
SIMATIC S5/505
Automation systems
Available as PDF only:
http://www.siemens.com/automation/
simatic/ftp/st50/html_76/st5098_e.pdf
Industrial Communication IK PI
Industrial Communication
for Automation and Drives
Order No.:
E86060-K6710-A101-B4-7600
SIMATIC HMI ST 80
Human Machine
Interface Systems
Order No.:
E86060-K4680-A101-B3-7600
PC-based Automation ST PC
Order No.:
E86060-K4670-B111-B3-7600
Sensor Technology FS 10
Factory Automation Sensors
Order No.:
E86060-K8310-A101-A1-7600
Order No.:
E86060-D6850-A100-C2-7400
Catalog CA01 - CA 01
the offline Mall of
Automation and Drives
Order No.:
E86060-D4001-A100-C3-7600
A&D Mall
Internet:
www.siemens.com/automation/mall
Trademarks
Automation and 2
Micro Automation SIMATIC S7-200
3
Catalog ST 70 · 2005
SIMATIC S7-300
Supersedes:
4
Catalog ST 70 · 2003
SIMATIC S7-400
The products contained in this
catalog are also contained in 5
the electronic catalog CA 01
Order No.:
E86060-D4001-A100-C3-7600 SIMATIC C7
s
Welcome to
Automation and Drives
worldwide.
potential.
ERP
Enterprise
Resource
Planning Ethernet
Production Material
MES Order Management
Management
Manufacturing
Execution Ethernet
Systems Production
Operations
Equipment
Management
Recording
SIMATIC
Machine Vision
Ethernet
Industrial
Industrial
Ethernet Industrial Wireless
Safety Integrated Communication/
MOBIC
PROCESS FIELD
PROFIBUS
PC-based Automation
AS-Interface
Building
Technology
Micro-Automation
GAMMA instabus and ECOFAST IP65
Actuator-Sensor Decentral
Interface Level Automation System
Field Instru-
mentation/
Analytics
Sensor HART
Technology
IQ-Sense
SIMOCODE-DP PROFIBUS PA
Motor
Protection SIWAREX Drive Systems/
and Control Weighing SIMODRIVE SINAMICS SINAMICS
Technology
Process/production U
I
cos o
P
W
automation
£ 110 kV
Building
ment
PAY PERIOD ENDING
Distribution
automation
DATE
SUN MON TUE WED THUR FRI SAT SUN TOTAL
IN
OUT
Maintenance
IN
OUT
OVERTIME
task DATE
SUN MON TUE WED THUR FRI
TOTAL HOURS
OUT
IN
OUT
TOTAL HOURS
checkup central ON DATE
OFF
SUN MON TUE WED THUR FRI SAT SUN TOTAL
OUT
OFF OUT
instabus EIB
CODES
REGULAR HOLIDAY OTHER
V=VACATION
H=HOLIDAY
S=SICK OVER THE HOURS
SICK VACATION
TIME & ONE-HALF
n = can be used/available
= can not be used/not available
SIMATIC S7-200
The Micro PLC SIMATIC S7-200 is truly in a class of its own:
it is both compact and highly powerful (e.g. in relation to its
real-time response), it is fast, features great communications
capabilities and comes with very user-friendly software and
hardware.
Graduated range of CPUs with many basic PLC functions.
Modular expansion capability for individual adaptations to
the respective tasks.
Can be easily networked over point-to-point interfaces (PPI)
with the functions programming, communication, operator
control and monitoring.
Programming with STEP 7-Micro/WIN - a software especially
optimized for the performance range of the S7-200.
Wizards for particularly easy and user-friendly operation.
Further information can be found at:
http://www.siemens.com/s7-200
SIMATIC S7-200 CPU 221 CPU 222 CPU 224 CPU 224 XP CPU 226
Data memory 2 KB 2 KB 8 KB 10 KB 10 KB
Processing time per 0.22 µs 0.22 µs 0.22 µs 0.22 µs 0.22 µs
binary instruction
Bit memories 256 256 256 256 256
Counters 256 256 256 256 256
Timers 256 256 256 256 256
Digital inputs/outputs max. 10; max. 40 / 38; max. 94 / 74; max. 94 / 74; max. 128 / 120;
10 integrated 14 integrated 24 integrated 24 integrated 40 integrated
Analog inputs/outputs max. 8/2 or 0/4 max. 28/7 or 0/14 max. 28/7 or 0/14 max. 28/7 or 0/14
3 integrated
HMI devices n n n n n
n = can be used/available
= can not be used/not available
SIMATIC S7-300
PLC with modular expansion capability, mainly for applications
in the manufacturing industry.
Complete integration in Totally Integrated Automation:
Efficient configuring and programming with STEP 7 -
also with the engineering tools.
Networking via MPI and SIMATIC NET - now also with
PROFINET.
The graduated CPU range, from entry-level CPUs right up to
high-performance CPUs, permits short machine cycle times
thanks to efficient processing speeds.
The following CPUs are available:
Standard CPUs, also with integrated PROFINET interface.
Failsafe CPUs for implementing failsafe applications with the
PROFIsafe profile and failsafe signal modules.
Compact CPUs with integrated I/O, integrated technological
functions and integrated communications interfaces for
special tasks.
Technology CPUs with integrated technology and motion
control functionality.
SIMATIC S7-300 CPU 312 CPU 314/ CPU 317-2 DP/ CPU 318-2 DP CPU 315F-2 DP CPU 317F-2 DP
315-2 DP 317-2 PN/DP
SIMATIC S7-300 CPU 312C CPU 313C CPU 313C-2 PtP/ CPU 314C-2 DP/ CPU 317T-2 DP
313-2 DP 314-2 DP
SIMATIC S7-400
PLC with excellent dynamics for system solutions in the
manufacturing and process technology.
Completely integrated in Totally Integrated Automation:
Efficient configuring and programming with STEP 7
and the engineering tools.
Networking via MPI and SIMATIC NET.
Extremely high level of performance with very short command
processing times and deterministic response times.
Well suited for executing programs involving many computing
tasks.
Fast communication via Ethernet and efficient connection
down to the field level via PROFIBUS.
Versatile module range:
Graded CPU performance, additionally multi-computing
Function and communication modules for technological
tasks, networking and connection to the IT world
Hot swapping of the signal modules.
Efficient configuring with high-level languages, e.g. SCL, and
graphical engineering tools.
Powerful diagnostics functions to achieve a higher availability
of the control.
Storage of all project data (e.g. program sources) direct on
the CPU to support with service jobs.
Special variants - based on the standard PLC - for applications
with demands on the high availability and fail-safety as well Further information can be found at:
as PC-based solutions. http://www.siemens.com/simatic-s7-400
SIMATIC S7-400 with CPU 412-1 CPU 414-2 CPU 416-2/ CPU 414-4H CPU 417-4H CPU 416F
CPU 412-2 CPU 414-3 416-3/417-4 for S7-400H/FH for S7-400F
User memory for program 72 (128 1)) KB 256 (700 2)) KB 1.4/2.8 3)/10 4) MB 700 KB 10 MB 1.4 MB
User memory for data 72 (128 1)) KB 256 (700 2)) KB 1.4/2.8 3)/10 4) MB 700 KB 10 MB 1.4 MB
Processing time per 1 K 0.1 ms 0.06 ms 0.04 (0.03 4)) ms 0.06 ms 0.03 ms 0.03 ms
Binary instructions
Bit memories 4096 8192 16384 8192 16384 16384
Counters 2048 2048 2048 2048 2048 2048
Timers 2048 2048 2048 2048 2048 2048
Digital channels 32768/32768 65536/65536 131072/131072 65536/65536 131072/131072 131072/131072
of which central 32768/32768 65536/65536 131072/131072 65536/65536 131072/131072 131072/131072
Analog channels 2048/2048 4096/4096 8192/8192 4096/4096 8192/8192 8192/8192
of which central 2048/2048 4096/4096 8192/8192 4096/4096 8192/8192 8192/8192
HMI devices n n n n n n
Communications MPI (multi-point MPI (multi-point MPI (multi-point MPI (multi-point MPI (multi-point MPI (multi-point
interface interface) interface) interface) interface) interface) interface)
PROFIBUS DP PROFIBUS DP PROFIBUS DP PROFIBUS DP PROFIBUS DP PROFIBUS DP
Networking PROFIBUS PROFIBUS PROFIBUS PROFIBUS PROFIBUS PROFIBUS
Ind. Ethernet Ind. Ethernet Ind. Ethernet Ind. Ethernet Ind. Ethernet Ind. Ethernet
Real-time clock integrated integrated integrated integrated integrated integrated
n = can be used/available 1) CPU 412-2 3) CPU 416-3
= can not be used/not available 2) CPU 414-3 4) CPU 417-4
SIMATIC C7
Compact unit for implementing complete machine control
systems incl. visualization where space is at a premium, e.g.
for the manufacturing industry or simple process engineering
tasks.
Low-cost solution consisting of an S7-300 CPU and a line-
oriented or pixel-graphics operator panel, i.e. PLC and OP basic
functionality in one device.
Compact housing that is easily installed, with permanent
wiring, rugged membrane keyboard, and backlit display.
Supports Cyrillic and various Asian character sets (Chinese,
Korean, Japanese).
Customized design for optimum adaptation to the machine.
Low engineering overhead with STEP 7 programming.
ProTool/WinCC flexible configuration and use of the shared
data management system.
Product variants with regard to communication interfaces
(MPI, DP), onboard I/O and S7-300 modules can be added,
e.g. also for technological tasks.
Further information can be found at:
http://www.siemens.com/simatic-c7
PLC-CPU CPU 313C CPU 315 1)/ CPU 314C-2 DP CPU 315-2 DP
CPU 315-2 DP 2)
CPU user memory 32 KB 48 1)/64 2) KB 64 KB 128 KB
OP OP 7 OP 170/ OP 270
TP 170B 3)
Number lines x characters 4 x 20 4 x 20 Pixel, vector graphics Pixel, vector graphics
per line, resolution 320 x 240 320 x 240
I/O 24 DI 16 DI 1) 24 DI 24 DI
16 DO 16 DO 1) 16 DO 16 DO
4 AI + 1 Pt100 4 AI 1) 4 AI + 1 Pt100 4 AI + 1 Pt100
2 AO 4 AO 1) 2 AO 2 AO
4 alarm/counter/
frequency 1)
Communication MPI MPI MPI MPI
interface PROFIBUS DP PROFIBUS DP PROFIBUS DP
(Master/Slave) 2) (Master/Slave) (Master/Slave)
Programming
PLC part STEP 7 Lite, STEP 7 STEP 7 Lite 1), STEP 7 STEP 7 STEP 7
HMI part STEP 7 Lite, STEP 7 ProTool Lite, ProTool, ProTool Lite, ProTool, WinCC flexible
ProTool/Pro, WinCC flexible 2) ProTool/Pro
Processor Mobile Intel Pentium 4, 2.2 GHz Mobile Intel Pentium 4, 2.2 GHz
incl. 512 KB 2nd level cache; incl. 512 KB 2nd level cache
Main memory 256 MB, can be expanded to max. 1 GB 512 MB, can be expanded to max. 1.5 GB
Display 14.1" TFT, resolution 1024 x 768 15" TFT, resolution 1024 x 768
optional 1400 x 1050 optional 1400 x 1050
Keyboard Notebook keyboard without numeric pad Wireless, standard keyboard with numeric pad
SIMATIC Microbox PC 420 SIMATIC Rack PC Industrial Lite 40 S SIMATIC Panel PC Industrial Lite 70 and 77
Ultra-compact for use directly at the machine High performance and scaleability Low-cost entry-level version for basic industrial
Maintenance-free thanks to operation without PCI- and AGP-Slots requirements
fan and hard disk CE marking for industry and office Basic industrial capability:
PC components from the Intel Embedded line vibration load 0.25 g, shock 1.0 g (in operation)
Dust protection
with long-term availability High electromagnetic compatibility:
Service-friendly CE marking for industrial applications
Scalable and expandable with up to
3 PC/104/Plus modules Transportation lock for expansion cards Latest PC technology
High system availability by rugged, EMC-suitable Monitoring functions PCI slots
design Long-term availability of spare parts
Long-term availability of spare parts SIMATIC Panel PC 670 and 870
SIMATIC Rack PC 840 Rugged high-performance PC
SIMATIC Box PC 620 and 840 Protection against vibration/shock during High industrial capability:
High-performance processor operation vibration load 1.0 g, shock 5.0 g (in operation)
Maximum compactness and performance Can be operated at high temp. levels High electromagnetic compatibility:
Can be operated at high temp. levels Efficient self-diagnostics CE marking for industrial applications
Powerful diagnostics Integrated PROFIBUS/MPI interface High industrial functionality:
(optional) PROFIBUS/MPI integrated, Ethernet on board
Integrated PROFIBUS/MPI interface ISA and PCI slots
(optional) ISA- and PCI-Slots
Low mounting depth (Panel PC 670),
ISA- and PCI-Slots High flexibility and expandability with the Maximum expandability (Panel PC 870)
components Optional direct control key module
High flexibility and expandability with the
components Long-term availability of spare parts Distributed configuration (optional)
Long-term availability of spare parts PC diagnostics/signaling software
Second hard disk (optional)
Distributed I/O
SIMATIC
Decentralized structures are widely accepted because they are S7-300
more flexible, easier, and many times more cost-effective. S7-200
ET 200S
Furthermore, PROFIBUS offers trend-setting innovations:
PROFIsafe for transmitting safety-relevant signals over the ET 200M
fieldbus
MICRO-
With PROFIdrive for Motion Control, the fieldbus becomes a MASTER ET 200L
drive bus as well
PROFINET - the innovative and open Industrial Ethernet
SIMOTION
standard for industrial automation from the field level right C/P/D ET 200iSP ET 200
up to the management level. eco
Vertical integration
A characteristic of vertical integration is the integrated and
transparent data communication from the ERP level over the
MES level and control level right down to the field level. It is
characterized by the increasing amalgamation of automation
technology and information technology and their standards in
the course of establishing company-wide information networks.
This permits the modularization and standardization of entire
subprocesses and thus a considerable increase in production
flexibility.
The vertical integration of SIMATIC PCS 7 into the company
environment comprises two aspects:
Integration into the company-wide information network and
Integration of field technology.
By linking the automation level with the IT world, process data
are made available company-wide for evaluation, planning,
coordination, and optimization of operating procedures as well
as production and business processes. At the same time the
requirements of international and distributed companies are
considered.
SIMATIC PCS 7 relies on PROFIBUS technology for integrating
distributed field systems. The PROFIBUS is simple, rugged and
reliable and is used worldwide in all sectors of the process,
manufacturing and hybrid industry - for incoming and outgoing
goods logistics as well as for primary and secondary processes.
It supports redundancy and fail-safety as well as online
extendibility and can be used in standard environments as well
as in hazardous areas, whereby it does not matter whether the
plant is equipped with classical signal inputs and outputs at
the remote I/O ET 200 or with the state-of-the-art field devices.
Industrial
PROFIBUS
0 1
00 00
00 7
00 00
s PROFIBUS
Addr.
6GK1415-0AA00
instabus EIB
Power DP/EIB-Link
DP/BF
EIB/BF
24V EIB
Phys. Adr.
2/2 Introduction
2/2 LOGO! logic module
2/12 LOGO!Power
2/12 LOGO!Power 12 V
2/14 LOGO!Power 24 V
2/16 LOGO!Contact
Siemens ST 70 · 2005
LOGO! logic module
Introduction
2 LOGO! logic module
■ Technical specifications
6ED1 052-1CC00-0BA4 6ED1 052-1MD00-0BA4 6ED1 052-1HB00-0BA4 6ED1 052-1FB00-0BA4
Supply voltages
Rated value
- 12 V DC Yes
- 24 V DC Yes Yes Yes
- 115 V DC Yes
- 230 V DC Yes
- permissible range, 20.4 V 10.8 V 20.4 V 100 V
lower limit (DC)
- permissible range, 28.8 V 28.8 V 28.8 V 253 V
upper limit (DC)
- 115 V AC Yes
- 230 V AC Yes
- permissible range, 20.4 V 85 V
lower limit (AC)
- permissible range, 26.4 V 265 V
upper limit (AC)
Time
Time switches
- Reserve power 80 h 80 h 80 h
• Number of digital inputs 8; of which 2 can be 8; of which 2 can be 8 8
for analog use (0..10V) for analog use (0..10V)
Digital outputs
• Number of digital outputs 4; Transistor 4; Relay 4; Relay 4; Relay
• Short-circuit protection Yes; electric (1 A) No; external fusing No; external fusing No; external fusing
of the output required required required
Relay outputs
Switching capacity
of the contacts
- at inductive load, max. 3A 3A 3A
- at resistive load, max. 0.3 A 10 A 10 A 10 A
EMC
• Emission of radio interference to Yes Yes Yes Yes
comply with EN 55 011
(limit class B)
Environmental requirements
Operating temperature
- min. 0 °C 0 °C 0 °C 0 °C
- max. 55 °C 55 °C 55 °C 55 °C
Degree of protection and
class of protection
- IP 20 Yes Yes Yes Yes
■ Technical specifications
6ED1 052-2CC00-0BA4 6ED1 052-2MD00-0BA4 6ED1 052-2HB00-0BA4 6ED1 052-2FB00-0BA4
Supply voltages
Rated value
- 12 V DC Yes
- 24 V DC Yes Yes Yes
- 115 V DC Yes
- 230 V DC Yes
- permissible range, lower limit 20.4 V 10.8 V 20.4 V 100 V
(DC)
- permissible range, upper limit 28.8 V 28.8 V 28.8 V 253 V
(DC)
- 115 V AC Yes
- 230 V AC Yes
- permissible range, lower limit 20.4 V 85 V
(AC)
- permissible range, upper limit 26.4 V 265 V
(AC)
Time
Time switches
- Number 8 8 8
- Reserve power 80 h 80 h 80 h
• Number of digital inputs 8; of which 2 can be 8; of which 2 can be 8 8
for analog use (0..10V) for analog use (0..10V)
Digital outputs
• Number of digital outputs 4; Transistor 4; Relay 4; Relay 4; Relay
• Short-circuit protection Yes; electric (1 A) No; external fusing No; external fusing No; external fusing
of the output required required required
Relay outputs
Switching capacity
of the contacts
- at inductive load, max. 3A 3A 3A
- at resistive load, max. 0.3 A 10 A 10 A 10 A
EMC
• Emission of radio interference Yes Yes Yes
to comply with EN 55 011
(limit class B)
Environmental requirements
Operating temperature
- min. 0 °C 0 °C 0 °C 0 °C
- max. 55 °C 55 °C 55 °C 55 °C
Degree of protection and
class of protection
- IP 20 Yes Yes Yes Yes
■ Technical specifications
6ED1 055-1CB00-0BA0 6ED1 055-1HB00-0BA0 6ED1 055-1MB00-0BA1 6ED1 055-1FB00-0BA1
Supply voltages
Rated value
- 12 V DC Yes
- 24 V DC Yes Yes Yes
- 115 V DC Yes
- 230 V DC Yes
- permissible range, 20.4 V 20.4 V 10.8 V 100 V
lower limit (DC)
- permissible range, 28.8 V 28.8 V 28.8 V 253 V
upper limit (DC)
- 115 V AC Yes
- 230 V AC Yes
- permissible range, 20.4 V 85 V
lower limit (AC)
- permissible range, 26.4 V 265 V
upper limit (AC)
Digital inputs
• Number of digital inputs 4 4 4 4
Digital outputs
• Number of digital outputs 4 4; Relay 4; Relay 4; Relay
• Short-circuit protection Yes; electric (1 A) No; external fusing No; external fusing No; external fusing
of the output required required required
Relay outputs
Switching capacity
of the contacts
- at inductive load, max. 3A 3A 3A
- at resistive load, max. 5A 5A 5A
- Continuous thermal current, 0.3 A
max.
EMC
• Emission of radio interference Yes Yes Yes Yes
to comply with EN 55 011
(limit class B)
Environmental requirements
Operating temperature
- min. 0 °C 0 °C 0 °C 0 °C
- max. 55 °C 55 °C 55 °C 55 °C
Degree of protection
and class of protection
- IP 20 Yes Yes Yes Yes
■ Overview
• Expansion module fo r LOGO! basic versions
• For communication between the LOGO! master and external
EIB components through EIB
An intelligent slave can be integrated into the AS-Interface sys- ■ Ordering Data Order No.
tem with the AS-Interface for LOGO! The modular interface
allows the different basic units to be integrated into the system AS-Interface connection for 3RK1 400-0CE10-0AA2
LOGO!
depending on the required functionality. In addition, the functio-
nality can be quickly and simply adapted to changed
requirements by replacing the basic unit.
The interface provides four inputs and four outputs for the sys-
tem. These I/Os, however, are not implemented in hardware, but
are only virtually available via the interface.
■ Application
of an overload or short-circuit, the primary switched-mode regu-
lator delivers a constant current, i.e. without restart attempts.
LOGO!Power naturally supplies the small LOGO! control modu-
les. They can, however, also be used elsewhere. Apart from their
function as system power supplies, LOGO!Power is also suitable
for supplying other consumers in the low-end performance
range. With the wide input range of 85 V to 264 V AC and radio
interference level B, they can be used universally in a diverse
range of applications in the low-end performance range. Be-
cause the advantages of the primary switched-mode regulator
convince customers right down the line.
For example:
• Enhanced protection of connecte d loads thanks to the regula-
ted output voltage
• Low power loss in the control cabinet thanks to the high effi-
ciency
• Compact design and low weight.
LOGO!Power supplies are primary switched-mode power sup- And LOGO!Power is predestined for equipment combinations in
plies that are optimized to the LOGO! logic modules in terms of standard N distribution boards thanks to
functionality and design. • Mounting on a 35 mm standard rail
In accordance with the required performance, the LOGO!Power • Low mounting depth and stepped cross-section.
supplies are available in two sizes, whereby the new generation
Of course, the power supplies comply with the relevant Euro-
is now even more compact despite the extended functionality.
pean and American regulations.
The width of the smaller type is only 54 mm now instead of the
previous 72 mm and the larger type has been reduced in size
from 126 mm to 72 mm. An extremely compact 4 A type with only
90 mm width completes the LOGO!Power family. An LED indica-
tes whether the output voltage level is correct and, in the event
Dimensions (W x H x D) in mm 54 x 90 x 55 72 x 90 x 55
Weight Approx. 0.17 kg Approx. 0.25 kg
Mounting Snap-mounting on DIN rail EN 50022-35x15/7.5 Snap-mounting on DIN rail EN 50022-35x15/7.5
Dimensions (W x H x D) in mm 54 x 90 x 55 72 x 90 x 55 90 x 90 x 55
Weight Approx. 0.17 kg Approx. 0.25 kg Approx. 0.34 kg
Mounting Snap-mounting on DIN rail Snap-mounting on DIN rail Snap-mounting on DIN rail
EN 50022-35x15/7.5 EN 50022-35x15/7.5 EN 50022-35x15/7.5
■ Overview
• Switching module for the direct switching of resistive loads
and motors
3/2 Introduction
3/41 Communication
3/41 EM 241 modem
3/42 EM 277 PROFIBUS DP module
3/43 CP 243-2
3/44 CP 243-1
3/45 CP 243-1 IT
3/55 Software
3/55 Software
Siemens ST 70 · 2005
SIMATIC S7-200
Introduction
S7-200
SIMATIC S7-200
3 • The micro PLC offers maximu m automation at minimum cost
• Extremely simple installation, programming and operation
• Large-scale integration, space-saving, powerful
• Can be used both for simple controls and for complex auto-
mation tasks
• All CPUs can be used in stan dalone mode, in networks and
within distributed structures
• Suitable for applications where programmable controllers
would not have been viable in the past
• With outstanding real-time performance and powerful com-
munication options (PPI, PROFIBUS DP, AS-Interface)
• Shipbuilding certification from
- American Bureau of Shipping (ABS)
- Bureau Veritas (BV)
- Des Norske Veritas (DNV)
- Germanischer Lloyd (GL)
- Lloyds Register of Shipping (LRS)
- Registro Italiano Navale (RINA)
- Nippon Kaiji Kyokai (NK)
SIPLUS S7-200
• The PLC for use in the hars hest environmental conditions
• With extended temperature range from -25 to +70°C
• Suitable for extraordinary medi al load (pollution gas atmos-
phere)
• Occasional short-term conden sation and increased mechani-
cal loading permissible
• With the proven PLC te chnology of the S7-200
• Convenient handling, programmi ng, maintenance and service
• Ideal for use in the automotive industry, environmental techno-
logy, mining, chemical plants, production technology, food in-
dustry etc.
• The alternative to expe nsive custom solutions
More Information you can find at:
http://www.siemens.com/siplus
■ Technical specifications
General Technical specifications SIMATIC S7-200 General Technical specifications SIPLUS S7-200
Degree of protection IP20 in accordance with IEC 529 Ambient
temperature
3
Ambient temperature
Temperature Horizontal mounting:
• Operation -25 °C to 70 °C
(95% relative humidity) Vertical mounting:
- With horizontal mounting 0 to 55°C -25 °C to 50 °C
- With vertical mounting 0 to 45 °C Relative humidity 5 to 95%;
transient condensation permis-
• Transport and storageGeneral -40 to +70 °C sible, corresponding to relative
- with 95% relative humidity 25 to 55 °C humidity (RH-) stress grade 2
according to IEC 1131-2 and
Isolation IEC 721 3-3 Cl. 3K5
• 5/24 V DC circuits Test voltage 500 V AC Transient icing -25 °C to 0 °C
IEC 721 3-3 Cl. 3K5
• 115/230 V AC circuits to ground Test voltage 1500 V AC
Atmospheric pressure 1080 to 795 hPa corresponding to
• 115/230 V AC circuits to Test voltage 1500 V AC
a height of -1000 to 2000 m
115/230 V AC circuits
Pollutant concentration SO2: < 0,5 ppm; relative humidity
• 230 V AC circuits to Test voltage 1500 V AC
<60% Test: 10 ppm, 4 days
5/24 V DC circuits
H2S: < 0,1 ppm; relative humidity
• 115 V AC circuits to Test voltage 1500 V AC <60% Test: 1 ppm, 4 days (accor-
5/24 V DC circuits ding to IEC 721 3-3; Class 3C3)
Electromagnetic compatibility Requirements of EMC law Mechanical environmental
• Noise immunity to Tested according to: conditions
EN 50082-2 IEC 801-2, IEC 801-3, IEC 801-4, Vibrations Type of vibration: frequency
EN 50141, EN 50204, IEC 801-5, progressions changing at 1
VDE 0160 octave per minute.
• Emitted interference according to Tested according to 2 Hz ≤ f ≤ 9 Hz, constant ampli-
EN 50081-1 and EN 55011, Class A, tude 3,0 mm 9 Hz ≤ f ≤ 150 Hz,
EN 50081-2 Group 1 and constant acceleration 1 g;
EN 55011, Class B, Duration of vibration:
Group 1 10 frequency progressions per
axis in each direction of the three
Mechanical rating mutually perpendicular axes;
Vibration testing according to
• Vibrations, tested according IEC 68, Part 2-6: IEC 68 section 2-6 (Sinus) and
to/tested with 10 to 57 Hz; IEC 721 3-3, Class 3M4
constant amplitude
0.3 mm; Shock Type of shock: semisinusoidal
58 to 150 Hz; shock strength: 15 g peak value,
constant acceleration 1 g duration shock direction 11 ms:
(mounted on DIN rail) or 3 shocks each in +/- direction
2 g (mounted in control cabinet); on each of the mutually
type of vibration: perpendicular axes
frequency cycles with a rate of Shock testing according
change of 1 octave/minute; to IEC 68 section 2-27
vibration duration:
10 frequency cycles per axis in Conformity EN 50155
each direction of the 3 mutually (railroad applications -
perpendicular axes electronical device on rail
vehicles)
• Shock, tested according to/tested IEC 68, Part 2-27/half-sine:
with shock strength 15 g (peak value),
duration 11 ms, 6 shocks on each
of the 3 mutually perpendicular
axes
■ Overview
3
■ Overview
• The high-performance package for complex technical tasks
• With additional PPI port for added flexibility and communica-
tion options
3
• With 40 inputs/outputs on board
• Expansion capability for max. 7 expansion racks
■ Technical specifications
6ES7 211-0AA23-0XB0 6ES7 211-0BA23-0XB0 6ES7 212-1AB23-0XB0 6ES7 212-1BB23-0XB0
Supply voltages
Rated value
- 24 V DC Yes Yes
- permissible range, 20.4 V 20.4 V
lower limit (DC)
- permissible range, 28.8 V 28.8 V
upper limit (DC)
- 120 V AC Yes Yes
- 230 V AC Yes Yes
- permissible range, 85 V 85 V
lower limit (AC)
- permissible range, 264 V 264 V
upper limit (AC)
- permissible frequency range, 47 Hz 47 Hz
lower limit
- permissible frequency range, 63 Hz 63 Hz
upper limit
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V 24 V 24 V 24 V
- permissible range, 20.4 V 5V 20.4 V 5V
lower limit (DC)
- permissible range, 28.8 V 30 V 28.8 V 30 V
upper limit (DC)
Load voltage L1
- Rated value (AC) 100 V; 100 to 230 V AC 100 V; 100 to 230 V AC
- permissible range, 5V 5V
lower limit (AC)
- permissible range, 250 V 250 V
upper limit (AC)
- permissible frequency range, 47 Hz 47 Hz
lower limit
- permissible frequency range, 63 Hz 63 Hz
upper limit
Current consumption
• Inrush current, max. 10 A; at 28.8 V 20 A; at 264 V 10 A; at 28.8 V 20 A; at 264 V
• from supply voltage L+, max. 450 mA; 80 to 450 mA 500 mA; 85 to 500 mA,
output current for
expansion modules
(5 V DC) 340 mA
• from supply voltage L1, max. 120 mA; 15 to 60 mA 140 mA; 20 to 70 mA
(240 V), 30 to 120 mA (240 V), 40 to 140 mA
(120 V); output current (120 V); output current
for expansion modules for expansion modules
(5 V DC) 340 mA (5 V DC) 340 mA
Supply voltages
1AD23-0XB0 1BD23-0XB0 2AD23-0XB0 2BD23-0XB0 2AD23-0XB0 2BD23-0XB0
3
Rated value
- 24 V DC Yes Yes Yes
- permissible range, lower limit 20.4 V 20.4 V 20.4 V
(DC)
- permissible range, upper limit 28.8 V 28.8 V 28.8 V
(DC)
- 120 V AC Yes Yes Yes
- 230 V AC Yes Yes Yes
- permissible range, lower limit 85 V 85 V 85 V
(AC)
- permissible range, upper limit 264 V 264 V 264 V
(AC)
- permissible frequency range, lo- 47 Hz 47 Hz 47 Hz
wer limit
- permissible frequency range, 63 Hz 63 Hz 63 Hz
upper limit
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V 24 V 24 V 24 V 24 V 24 V
- permissible range, lower limit 20.4 V 5V 20.4 V 5V 20.4 V 5V
(DC)
- permissible range, upper limit 28.8 V 30 V 28.8 V 30 V 28.8 V 30 V
(DC)
Load voltage L1
- Rated value (AC) 100 V; 100 to 100 V; 100 to 100 V; 100 to
230 V AC 230 V AC 230 V AC
- permissible range, lower limit 5V 5V 5V
(AC)
- permissible range, upper limit 250 V 250 V 250 V
(AC)
- permissible frequency range, lo- 47 Hz 47 Hz 47 Hz
wer limit
- permissible frequency range, 63 Hz 63 Hz 63 Hz
upper limit
Current consumption
• Inrush current, max. 12 A; at 28.8 V 20 A; at 264 V 12 A; at 28.8 V 20 A; at 264 V 10 A; at 28.8 V 20 A; at 264 V
• from supply voltage L+, max. 700 mA; 900 mA; 1,050 mA;
110 to 700 mA, 120 to 900 mA, 150 to 1050 mA,
output current output current output current
for expansion for expansion for expansion
modules (5 V modules (5 V modules (5 V
DC) 660 mA DC) 660 mA DC) 1000 mA
• from supply voltage L1, max. 200 mA; 30 to 220 mA; 35 to 320 mA; 40 to
100 mA (240 V), 100 mA (240 V), 160 mA (240 V),
60 to 200 mA 70 to 220 mA 80 to 320 mA
(120 V); (120 V); (120 V);
output current output current output current
for expansion for expansion for expansion
modules (5 V modules (5 V modules (5 V
DC) 600 mA DC) 600 mA DC) 1000 mA
back-up battery
- Backup time 100 h; (min. 70 h 100 h; (min. 70 h 100 h; (min. 70 h 100 h; (min. 70 h 100 h; (min. 70 h 100 h; (min. 70 h
at 40 °C); at 40 °C); at 40 °C); at 40 °C); at 40 °C); at 40 °C);
200 days (typ.) 200 days (typ.) 200 days (typ.) 200 days (typ.) 200 days (typ.) 200 days (typ.)
with optional with optional with optional with optional with optional with optional
battery module battery module battery module battery module battery module battery module
Memory
- Number of memory modules 1; pluggable 1; pluggable 1; pluggable 1; pluggable 1; pluggable 1; pluggable
(optional) memory module, memory module, memory module, memory module, memory module, memory module,
content identi- content identi- content identi- content identi- content identi- content identi-
cal to integral cal to integral cal to integral cal to integral cal to integral cal to integral
EEPROM, EEPROM, EEPROM, EEPROM, EEPROM, EEPROM,
in addition, in addition, in addition, in addition, in addition, in addition,
recipes, data recipes, data recipes, data recipes, data recipes, data recipes, data
logs and other logs and other logs and other logs and other logs and other logs and other
files can be files can be files can be files can be files can be files can be
saved. saved. saved. saved. saved. saved.
• Data memory and program
memory
- Data memory, max. 8 KByte 8 KByte 10 KByte 10 KByte 10 KByte 10 KByte
- Program memory, max. 12 KByte; 12 KByte; 16 KByte; 16 KByte; 24 KByte; 24 KByte;
8 Kbytes for 8 Kbytes for 12 Kbytes for 12 Kbytes for 16 Kbytes with 16 Kbytes with
active run-time active run-time active run-time active run-time active run-time active run-time
edit edit edit edit edit edit
Backup
- available Yes; Program: Yes; Program: Yes; Program: Yes; Program: Yes; Program: Yes; Program:
entire program entire program entire program entire program entire program entire program
maintenance- maintenance- maintenance- maintenance- maintenance- maintenance-
free in integral free in integral free in integral free in integral free in integral free in integral
EEPROM, EEPROM, EEPROM, EEPROM, EEPROM, EEPROM,
programmable programmable programmable programmable programmable programmable
via CPU; data: via CPU; data: via CPU; data: via CPU; data: via CPU; data: via CPU; data:
entire DB 1 entire DB 1 entire DB 1 entire DB 1 entire DB 1 entire DB 1
loaded from loaded from loaded from loaded from loaded from loaded from
PG/PC mainte- PG/PC mainte- PG/PC mainte- PG/PC mainte- PG/PC mainte- PG/PC mainte-
nance-free in nance-free in nance-free in nance-free in nance-free in nance-free in
integral integral integral integral integral integral
EEPROM, EEPROM, EEPROM, EEPROM, EEPROM, EEPROM,
current values current values current values current values current values current values
of DB 1 in RAM, of DB 1 in RAM, of DB 1 in RAM, of DB 1 in RAM, of DB 1 in RAM, of DB 1 in RAM,
retentive flags, retentive flags, retentive flags, retentive flags, retentive flags, retentive flags,
timers, counters timers, counters timers, counters timers, counters timers, counters timers, counters
etc., mainte- etc., mainte- etc., mainte- etc., mainte- etc., mainte- etc., mainte-
nance free nance free nance free nance free nance free nance free
via super via super via super via super via super via super
capacitor; capacitor; capacitor; capacitor; capacitor; capacitor;
optional battery optional battery optional battery optional battery optional battery optional battery
CPU/processing times
• for bit instruction, max. 0.22 µs 0.22 µs 0.22 µs 0.22 µs 0.22 µs 0.22 µs
Timers/counters and their reten-
tive characteristics
S7 counter
- Number 256 256 256 256 256 256
• of which retentive with battery
- adjustable Yes; via super Yes; via super Yes; via super Yes; via super Yes; via super Yes; via super
capacitor or capacitor or capacitor or capacitor or capacitor or capacitor or
battery battery battery battery battery battery
- lower limit 1 1 1 1 1 1
- upper limit 256 256 256 256 256 256
• Counting range
- lower limit 0 0 0 0 0 0
- upper limit 32,767 32,767 32,767 32,767 32,767 32,767
S7 times
1AD23-0XB0 1BD23-0XB0 2AD23-0XB0 2BD23-0XB0 2AD23-0XB0 2BD23-0XB0
3
- Number 256 256 256 256 256 256
• of which retentive with battery
- adjustable Yes; via super Yes; via super Yes; via super Yes; via super Yes; via super Yes; via super
capacitor or capacitor or capacitor or capacitor or capacitor or capacitor or
battery battery battery battery battery battery
- upper limit 64 64 64 64 64 64
• Timing range
- lower limit 1 ms 1 ms 1 ms 1 ms 1 ms 1 ms
- upper limit 54 min; 4 times, 54 min; 4 times, 54 min; 4 times, 54 min; 4 times, 54 min; 4 times, 54 min; 4 times,
1 ms to 30 s 1 ms to 30 s 1 ms to 30 s 1 ms to 30 s 1 ms to 30 s 1 ms to 30 s
16 times, 10 ms 16 times, 10 ms 16 times, 10 ms 16 times, 10 ms 16 times, 10 ms 16 times, 10 ms
to 5 min to 5 min to 5 min to 5 min to 5 min to 5 min
236 times, 100 236 times, 100 236 times, 100 236 times, 100 236 times, 100 236 times, 100
ms to 54 min ms to 54 min ms to 54 min ms to 54 min ms to 54 min ms to 54 min
Data areas and their retentive
characteristics
Flags
- Number 32 Byte 32 Byte 32 Byte 32 Byte 32 Byte 32 Byte
- adjustable retentivity Yes; M0.0 to Yes; M0.0 to Yes; M0.0 to Yes; M0.0 to Yes; M0.0 to Yes; M0.0 to
M31.7 M31.7 M31.7 M31.7 M31.7 M31.7
- of which retentive with battery 0 to 255, via 0 to 255, via 0 to 255, via 0 to 255, via 0 to 255, via 0 to 255, via
super capacitor super capacitor super capacitor super capacitor super capacitor super capacitor
or battery, or battery, or battery, or battery, or battery, or battery,
adjustable adjustable adjustable adjustable adjustable adjustable
- of which retentive without battery 0 to 112 in 0 to 112 in 0 to 112 in 0 to 112 in 0 to 112 in 0 to 112 in
EEPROM, EEPROM, EEPROM, EEPROM, EEPROM, EEPROM,
adjustable adjustable adjustable adjustable adjustable adjustable
Configuration
• Connectable programming de- SIMATIC PG/PC, SIMATIC PG/PC, SIMATIC PG/PC, SIMATIC PG/PC, SIMATIC PG/PC, SIMATIC PG/PC,
vices/PCs Standard PC Standard PC Standard PC Standard PC Standard PC Standard PC
• Central units/expansion units, 7 expansion 7 expansion 7 expansion 7 expansion 7 expansion 7 expansion
max. modules. modules. modules. modules. modules. modules.
Only expansion Only expansion Only expansion Only expansion Only expansion Only expansion
modules of the modules of the modules of the modules of the modules of the modules of the
S7-22x series S7-22x series S7-22x series S7-22x series S7-22x series S7-22x series
can be used. can be used. can be used. can be used. can be used. can be used.
(Because of the (Because of the (Because of the (Because of the (Because of the (Because of the
limited output limited output limited output limited output limited output limited output
current, the use current, the use current, the use current, the use current, the use current, the use
of expansion of expansion of expansion of expansion of expansion of expansion
modules may be modules may be modules may be modules may be modules may be modules may be
subject to subject to subject to subject to subject to subject to
restrictions.) restrictions.) restrictions.) restrictions.) restrictions.) restrictions.)
I/O expansions
- Analog inputs/outputs, max. 35; 35; 38; 38; 35; 35;
max. 28 inputs max. 28 inputs 2 on board 2 on board max. 28 inputs max. 28 inputs
and 7 outputs and 7 outputs inputs and inputs and and 7 outputs and 7 outputs
(EM) or max. (EM) or max. one output, one output, (EM) or max. (EM) or max.
0 inputs and 0 inputs and in addition in addition 0 inputs and 0 inputs and
14 outputs (EM) 14 outputs (EM) max. 28 inputs max. 28 inputs 14 outputs (EM) 14 outputs (EM)
and 7 outputs and 7 outputs
(EM) or max. (EM) or max.
0 inputs and 0 inputs and
14 outputs (EM) 14 outputs (EM)
- Digital inputs/outputs, max. 168; 168; 168; 168; 148; 148;
max. 94 inputs max. 94 inputs max. 94 inputs max. 94 inputs max. 128 inputs max. 128 inputs
and 74 outputs and 74 outputs and 74 outputs and 74 outputs and 120 outputs and 120 outputs
(CPU+EM) (CPU+EM) (CPU+EM) (CPU+EM) (CPU+EM) (CPU+EM)
- AS interface inputs/outputs, 62; AS interface 62; AS interface 62; AS interface 62; AS interface 62; AS interface 62; AS interface
max. A/B slaves A/B slaves A/B slaves A/B slaves A/B slaves A/B slaves
(CP 243-2) (CP 243-2) (CP 243-2) (CP 243-2) (CP 243-2) (CP 243-2)
2nd interface
1AD23-0XB0 1BD23-0XB0 2AD23-0XB0 2BD23-0XB0 2AD23-0XB0 2BD23-0XB0
3
• Type of interface integrated RS integrated RS integrated RS integrated RS
485 interface 485 interface 485 interface 485 interface
• Physical RS 485 RS 485 RS 485 RS 485
Functionality
- MPI Yes; as MPI Yes; as MPI Yes; as MPI Yes; as MPI
Slave for data Slave for data Slave for data Slave for data
exchange with exchange with exchange with exchange with
MPI Masters MPI Masters MPI Masters MPI Masters
(S7-300/S7-400- (S7-300/S7-400- (S7-300/S7-400- (S7-300/S7-400-
CPUs, OPs, CPUs, OPs, CPUs, OPs, CPUs, OPs,
TDs, Push But- TDs, Push But- TDs, Push But- TDs, Push But-
ton Panels); ton Panels); ton Panels); ton Panels);
internal S7-200 internal S7-200 internal S7-200 internal S7-200
CPU/CPU CPU/CPU CPU/CPU CPU/CPU
communication communication communication communication
is limited in the is limited in the is limited in the is limited in the
MPI network; MPI network; MPI network; MPI network;
transmission transmission transmission transmission
rates 19.2/187.5 rates 19.2/187.5 rates 19.2/187.5 rates 19.2/187.5
kbit/s kbit/s kbit/s kbit/s
- PPI Yes; with PPI Yes; with PPI Yes; with PPI Yes; with PPI
protocol for protocol for protocol for protocol for
programming programming programming programming
functions, functions, functions, functions,
HMI functions HMI functions HMI functions HMI functions
(TD 200, OP), (TD 200, OP), (TD 200, OP), (TD 200, OP),
S7-200 internal S7-200 internal S7-200 internal S7-200 internal
CPU/CPU CPU/CPU CPU/CPU CPU/CPU
communication; communication; communication; communication;
transmission transmission transmission transmission
rates rates rates rates
9.6/19.2/187.5 9.6/19.2/187.5 9.6/19.2/187.5 9.6/19.2/187.5
kbit/s kbit/s kbit/s kbit/s
- Serial data transmission Yes; as a freely Yes; as a freely Yes; as a freely Yes; as a freely
programmable programmable programmable programmable
interface with an interface with an interface with an interface with an
interrupt option interrupt option interrupt option interrupt option
for serial data for serial data for serial data for serial data
transmission transmission transmission transmission
with external with external with external with external
units with ASCII units with ASCII units with ASCII units with ASCII
ptotocol baud ptotocol baud ptotocol baud ptotocol baud
rates: rates: rates: rates:
0.3/0.6/1.2/2.4/4. 0.3/0.6/1.2/2.4/4. 0.3/0.6/1.2/2.4/4. 0.3/0.6/1.2/2.4/4.
8/9.6/19.2/38.4 8/9.6/19.2/38.4 8/9.6/19.2/38.4 8/9.6/19.2/38.4
kbit/s; at 1.2 to kbit/s; at 1.2 to kbit/s; at 1.2 to kbit/s; at 1.2 to
38.4 kbit/s, the 38.4 kbit/s, the 38.4 kbit/s, the 38.4 kbit/s, the
PC/PPI cable PC/PPI cable PC/PPI cable PC/PPI cable
can be used as can be used as can be used as can be used as
an RS232/RS485 an RS232/RS485 an RS232/RS485 an RS232/RS485
converter converter converter converter
MPI
- Transmission rate, max. 187.5 kBit/s 187.5 kBit/s 187.5 kBit/s 187.5 kBit/s
- Transmission rate, min. 19.2 kBit/s 19.2 kBit/s 19.2 kBit/s 19.2 kBit/s
Programming language
- LAD Yes Yes Yes Yes Yes Yes
- FBD Yes Yes Yes Yes Yes Yes
- STL Yes Yes Yes Yes Yes Yes
• Instruction set Bit logic instruc- Bit logic instruc- Bit logic instruc- Bit logic instruc- Bit logic instruc- Bit logic instruc-
tions, compare tions, compare tions, compare tions, compare tions, compare tions, compare
instructions, instructions, instructions, instructions, instructions, instructions,
timer instruc- timer instruc- timer instruc- timer instruc- timer instruc- timer instruc-
tions, counter tions, counter tions, counter tions, counter tions, counter tions, counter
instructions, instructions, instructions, instructions, instructions, instructions,
clock instruc- clock instruc- clock instruc- clock instruc- clock instruc- clock instruc-
tions, integer tions, integer tions, integer tions, integer tions, integer tions, integer
math instruc- math instruc- math instruc- math instruc- math instruc- math instruc-
tions, floating- tions, floating- tions, floating- tions, floating- tions, floating- tions, floating-
point math point math point math point math point math point math
instructions, instructions, instructions, instructions, instructions, instructions,
numeric func- numeric func- numeric func- numeric func- numeric func- numeric func-
tions, move tions, move tions, move tions, move tions, move tions, move
instructions, instructions, instructions, instructions, instructions, instructions,
table instruc- table instruc- table instruc- table instruc- table instruc- table instruc-
tions, logic tions, logic tions, logic tions, logic tions, logic tions, logic
instructions, instructions, instructions, instructions, instructions, instructions,
shift and rotate shift and rotate shift and rotate shift and rotate shift and rotate shift and rotate
instructions, instructions, instructions, instructions, instructions, instructions,
conversion conversion conversion conversion conversion conversion
instructions, instructions, instructions, instructions, instructions, instructions,
program control program control program control program control program control program control
instructions, instructions, instructions, instructions, instructions, instructions,
interrupt and interrupt and interrupt and interrupt and interrupt and interrupt and
communicati- communicati- communicati- communicati- communicati- communicati-
ons instructions, ons instructions, ons instructions, ons instructions, ons instructions, ons instructions,
logic stack logic stack logic stack logic stack logic stack logic stack
instructions instructions instructions instructions instructions instructions
• User program protection/pass- Yes; 3-stage Yes; 3-stage Yes; 3-stage Yes; 3-stage Yes; 3-stage Yes; 3-stage
word protection password pro- password pro- password pro- password pro- password pro- password pro-
tection tection tection tection tection tection
• Program execution free cycle (OB free cycle (OB free cycle (OB free cycle (OB free cycle (OB free cycle (OB
1), interrupt-dri- 1), interrupt-dri- 1), interrupt-dri- 1), interrupt-dri- 1), interrupt-dri- 1), interrupt-dri-
ven, time-driven ven, time-driven ven, time-driven ven, time-driven ven, time-driven ven, time-driven
(1 to 255 ms) (1 to 255 ms) (1 to 255 ms) (1 to 255 ms) (1 to 255 ms) (1 to 255 ms)
• Program organization 1 OB, 1 DB, 1 OB, 1 DB, 1 OB, 1 DB, 1 OB, 1 DB, 1 OB, 1 DB, 1 OB, 1 DB,
1 SDB 1 SDB 1 SDB 1 SDB 1 SDB 1 SDB
subprograms subprograms subprograms subprograms subprograms subprograms
with/without with/without with/without with/without with/without with/without
parameter parameter parameter parameter parameter parameter
transfer transfer transfer transfer transfer transfer
• Number of sub-programs, max. 64 64 64 64 64 64
Digital inputs
• Number of digital inputs 14 14 14 14 24 24
Length of cable
- Length of cable shielded, 500 m; Stan- 500 m; Stan- 500 m; Stan- 500 m; Stan- 500 m; Stan- 500 m; Stan-
max dard input: dard input: dard input: dard input: dard input: dard input:
500m, fast coun- 500m, fast coun- 500m, fast coun- 500m, fast coun- 500m, fast coun- 500m, fast coun-
ters: 50m ters: 50m ters: 50m ters: 50m ters: 50m ters: 50m
- Length of cable unshielded, 300 m; not for 300 m; not for 300 m; not for 300 m; not for 300 m; not for 300 m; not for
max high-speed sig- high-speed sig- high-speed sig- high-speed sig- high-speed sig- high-speed sig-
nals nals nals nals nals nals
• m/p reading Yes; optional, Yes; optional, Yes; optional, Yes; optional, Yes; optional, Yes; optional,
per group per group per group per group per group per group
Input voltage
- Rated value, DC 24 V 24 V 24 V 24 V 24 V 24 V
- for signal "0" 0 to 5 V 0 to 5 V 0 to 5 V; 0 to 1V 0 to 5 V0 to 1V 0 to 5 V 0 to 5 V
(I0.3 to I0.5) (I0.3 to I0.5)
- for signal "1" min. 15 V min. 15 V min. 15 V; min. 15 V min. 15 V min. 15 V
at least 4V at least 4V
(I0.3 to I0.5) (I0.3 to I0.5)
Input current
- for 1 signal, typical 2.5 mA 2.5 mA 2.5 mA; 8 mA 2.5 mA; 8 mA 2.5 mA 2.5 mA
for I0.3 to I0.5 for I0.3 to I0.5
■ Overview
• The SIPLUS S7-200 CPUs for us e in the harshest environmen-
3 tal conditions
• With extended temperature range from -25 to +70°C
• Suitable for extraordinary medi al load (pollution gas atmos-
phere)
• Occasional short-term conden sation and increased mechani-
cal loading permissible
• With the proven PLC te chnology of the S7-200
• Convenient handling, programmi ng, maintenance and service
• The alternative to expe nsive custom solutions
More Information you can find at:
http://www.siemens.com/siplus
■ Overview
• Digital inputs/outputs to suppl ement the onboard I/Os of the
CPUs
• For flexible adaptation of PLC to respective task
3
• For subsequent upgrading of th e system with additional inputs
Ordering Data
■ Overview
• Analog inputs and outputs for the SIMATIC S7-200
• With extremely short conversion times 3
• For connections of analog sensors and actuators without
additional amplifier
• For solving the more complex automation tasks
■ Overview
• For user-friendly, high precision temperature detection
3 • 7 standard types of th ermocouple can be used
• For measuring low-level analog signals ( ±80 mV), as well
• Easy to install in an existing system
■ Technical specifications
6ES7 231-7PD22-0XA0 6ES7 231-7PD22-0XA0
Current consumption Analog value formation
• from load voltage L+ (no load), 60 mA • Measuring principle Sigma-Delta
max.
Integration and conversion
• from backplane bus 5 V DC, max. 87 mA time/triggering per channel
• Power dissipation, typical 1.8 W - with over-range (bits incl. sign), 16 Bit; Temperature 0.1 °C / 0.1 °F
Connection system max
• Pluggable I/O terminals No - Interference voltage 85 dB at 50 / 60 / 400 Hz
suppression for interference
Analog inputs frequency f1 in Hz
• Number of analog inputs 4 Displayable conversion value
• Length of cable shielded, max 100 m; to sensor range
• Permissible input voltage for the 30 V - bipolar signals -27,648 to +27,648
voltage input (destruction limit),
max. Error/accuracies
• Loop resistance line 100 Ω • Cold connection point +/-1.5 °C
• Update time (all channels) 405 ms • Repeatability in the settled state +/- 0.05 %
at 25°C (relative to the output
Input ranges (rated values), range)
voltages
Operational limit in the entire
- -80 mV to +80 mV Yes temperature range
Input ranges (rated values), - Relative to the output range, +/- 0.1 %
thermocouples voltage
- Type E Yes Interference voltage suppression
- Type J Yes for f = n x (fl +/- 1 %)
- Type K Yes - Common-mode voltage, max. 120 V; AC
- Type N Yes - Common-mode interference, 120 dB; at 120 V AC
- Type R Yes min
- Type S Yes Potentials/ electrical isolation
- Type T Yes Analog output functions
- Electrical isolation, Yes
analog inputs
Dimensions and weight
• Weight, approx. 210 g
• Width 71.2 mm
• Height 80 mm
• Depth 62 mm
■ Overview
• For user-friendly, high precision temperature detection
3 • Supports 31 standard resistance temperature sensors
• Easy to install in an existing system
■ Technical specifications
6ES7 231-7PB22-0XA0 6ES7 231-7PB22-0XA0
Current consumption Analog value formation
• from load voltage L+ (no load), 60 mA • Measuring principle Sigma-Delta
max.
Integration and conversion
• from backplane bus 5 V DC, max. 87 mA time/triggering per channel
• Power dissipation, typical 1.8 W; Sensor: 1 mW - with over-range (bits incl. sign), 16 Bit; Temperature 0.1 °C / 0.1 °F
Connection system max
• Pluggable I/O terminals No - Interference voltage 85 dB at 50 / 60 / 400 Hz
suppression for interference
Analog inputs frequency f1 in Hz
• Number of analog inputs 2 Displayable conversion value
• Length of cable shielded, max 100 m; to sensor range
• Permissible input voltage for the 30 V; 30 V DC (sensor), 5 V DC - bipolar signals -27,648 to +27,648
voltage input (destruction limit), (source)
max. Error/accuracies
• Loop resistance line 20 Ω; max. 2.7 ohms for Cu • Repeatability in the settled state +/- 0.05 %
at 25°C (relative to the output
• Update time (all channels) 405 ms; 700 ms at Pt 10000 range)
Input ranges (rated values), Operational limit in the entire
resistances temperature range
- 0 to 150 ohms Yes - Relative to the output range, +/- 0.1 %
- 0 to 300 ohms Yes voltage
- 0 to 600 ohms Yes Interference voltage suppression
Input ranges (rated values), for f = n x (fl +/- 1 %)
resistance thermometer - Common-mode voltage, max. 0V
- Cu 10 Yes - Common-mode interference, 120 dB; at 120 V AC
- Ni 10 Yes min
- Ni 1000 Yes Potentials/ electrical isolation
- Ni 120 Yes Analog output functions
- Pt 100 Yes - Electrical isolation, Yes
analog inputs
- Pt 1000 Yes
- Pt 10000 Yes Dimensions and weight
- Pt 200 Yes • Weight, approx. 210 g
- Pt 500 Yes • Width 71.2 mm
• Height 80 mm
• Depth 62 mm
■ Overview
• Function modules for simple positioning tasks (1 axis)
• Stepper motors and servo moto rs from the Micro Stepper to
the high-performance servo drive can be connected
3
• Flexible connection possibilities
• Full support from STEP 7-Micro/WIN with parameterization
and startup
■ Technical specifications
6ES7 253-1AA22-0XA0 Sensor
Supply voltages Connectable encoders
Rated value - 2-wire BEROS Yes
- permissible range, 11 V - permissible closed-circuit 1 mA
lower limit (DC) current (2-wire BEROS), max.
- permissible range, 30 V Drive interface
upper limit (DC) Signal output I
Current consumption - Number 4; choice of RS422/RS485 or
• from backplane bus 5 V DC, max. 190 mA 5 V DC
• from supply voltage L+, max. 300 mA; from 12 V DC, - Type RS422/RS485 electrically
130 mA from 24 V DC isolated (P0+, P0-, P1+, P1-)
- Differential output voltage, min. 2.8 V; RL=200 ohms
Configuration
- Pulse frequency 200 kHz; P0+, P0-, P1+, P1-, P0,
• Number of modules per CPU max. 5 with CPU 226/226XM,
P1
max. 3 with CPU 224,
max. 1 with CPU 222 - Length of cable, max. 10 m; 10 m shielded;
1 m unshielded
Digital inputs
Signal output III
• Number of digital inputs 5
- Type 5 V DC isolated
• Functions Stop (STP),
(P0, P1, DIS, CLR)
reference point switch (RPS),
upper limit switch (LMT+), - Output voltage 30 V DC
lower limit switch (LMT-), - Output current 50 mA; output delay
zero point (ZP) (DIS, CLR) max. 30 µs
Length of cable Potentials/ electrical isolation
- Length of cable shielded, max 100 m; STP, RPS, LMT+, Digital input functions
LMT- 100 m, ZP 10 m
- between the channels Yes
- Length of cable unshielded, max 30 m; STP, RPS, LMT+,
- between the channels, 1 (STP, RPS, ZP),
LMT- 30 m, ZP not advisable
in groups of 2 (LMT-, LMT+)
• Type IEC Type 1, p-reading
Dimensions and weight
Input voltage • Weight, approx. 190 g
- Rated value, DC 24 V
• Width 71.2 mm
- for signal "0" STP, RPS, LMT+, LMT- DC 5 V;
ZP DC 1 V • Height 80 mm
- for signal "1" STP, RPS, LMT+, LMT- DC 15 V; • Depth 62 mm
ZP DC 3 V
Input delay (at rated value
of the input voltage)
• For standard inputs
- Parameterizable Yes; STP, RPS, LMT+,
LMT- 0.2 to 12.8 ms
ZP min 2 µs
■ Overview
• Modem expansion modu le for SIMATIC S7-200
• The Plug&Play solution for a ll classical modem tasks in the
PLC field
3
• Used for remote maintenance/ remote diagnostics, CPU-to-
CPU/PC communication or SMS/pager messaging
• Minimal engineering outlay required
• Replaces external modems connected via the communicati-
ons interface of the CPU
• Easy to retrofit
■ Overview
• For connection of the S7-22x to PROFIBUS DP (as slave) and
3 MPI
• Can be simultaneously operat ed as MPI slave and DP slave
• Transmission rate max. 12 Mbps
• Can be used with CPU from version 6ES7 22x-xxx 21-xxxx
■ Technical specifications
6ES7 277-0AA22-0XA0 6ES7 277-0AA22-0XA0
Voltages and currents Connection system
Load voltage L+ • Pluggable I/O terminals No
- Rated value (DC) 24 V PROFIBUS DP
- permissible range, 20.4 V • Transmission rate, max. 12 Mbit/s;
lower limit (DC) 9.6 / 19.2 / 45.45 / 93.75 / 187.5 /
- permissible range, 28.8 V 500 kbit/s
upper limit (DC) 1 / 1.5 / 3 / 6 / 12 Mbit/s
Current consumption • Station addresses 0 to 99, adjustable
• from backplane bus 5 V DC, max. 150 mA • Length of cable, max. 1,200 m;
100 to 1200 m, depending on the
• from sensor current or ext. 180 mA; 30 to 180 mA transmission rate
power supply (24 V DC), max.
• Number of stations in the system, 126; of which max. 99 EM 277
• Power dissipation, typical 2.5 W max.
Configuration • Number of stations per segment, 32
• Connectable stations TD 200 from V2.0, max.
OP, TP, PG/PC, S7-300/400, • Automatic transmission Yes
PROFIBUS DP-Master speed detection
Communication functions Dimensions and weight
• Bus protocol/transfer protocol PROFIBUS DP (Slave), • Weight, approx. 175 g
MPI (Slave)
• Width 71.2 mm
Number of connections
• Height 80 mm
- MPI connections, max. 6
• Depth 62 mm
- MPI connections reserved 1
for OP communication
- MPI connections reserved 1
for PG communication
Interfaces
• Number of RS485 interfaces 1
5 V DC
- Output current, max. 90 mA
24 V DC
- Voltage range 20.4 to 28.8 V
- Output current, max. 120 mA
- Current limiting 0.7 to 2.4 A
• Indication of errors (incl. AS-Interface voltage errors, configu- CP 243-2 communications pro- 6GK7 243-2AX01-0XA0
cessor A)
ration errors) with LEDs in the front panel
For connection of SIMATIC S7-
• Compact enclosure designed to match the new generation of
SIMATIC S7-200. 200 (2nd generation) to AS-Inter-
face with bus connector
Manual for CP 243-2
Including AS-Interface fundamen-
tals and diskette with program
examples
paper version
• German 6GK7 243-2AX00-8AA0
• English 6GK7 243-2AX00-8BA0
• French 6GK7 243-2AX00-8CA0
• Spanish 6GK7 243-2AX00-8DA0
• Italian 6GK7 243-2AX00-8EA0
A) Subject to export regulations: AL: N and ECCN: EAR99H
■ Overview
The regulated load power supply for the SIMATIC S7-200.
3 • Coordinated design and functiona lity, can be integrated easily
into the PLC network.
• For reliably powering the controller, encoders and sensors
with 24 V DC, 3.5 A.
• Flexible implementation, either in industry or in the domestic
supply system
■ Technical specifications
Type 3.5 A Type 3.5 A
Order No. 6EP1 332-1SH31 Order No. 6EP1 332-1SH31
Input Single-phase AC Efficiency
Rated voltage Vin rated 120/230 V AC Efficiency at Vout rated, Iout rated Approx. 84 %
Settable using wire jumper
Power loss at Vout rated, Iout rated Approx. 16 W
Voltage range 93 to 132 V/187 to 264 V AC
Control
Overvoltage strength 2.3 x Vinrated, 1.3 ms
Dyn. mains compensation ± 0.3 % Vout
Mains buffering Iout rated > 20 ms at Vin = 187 V (Vin rated ±15 %)
Rated line frequency; range 50/60 Hz, 47 to 63 Hz Dyn. load compensation < ± 10 % Vout (typ. ± 3 % Vout)
(Iout: 50/100/50 %)
Rated currentIin rated 1.65/0.95 A
Settling time
Inrush current limitation (+25 °C) < 33 A, < 3 ms (Vin = 230 V)
• Load step from 50 to 100% < 5 ms
I2t < 1.0 A2s
• Load step from 100 to 50% < 5 ms
Integrated line-side fuse T 2.5 A/250 V (not accessible)
Protection and monitoring
Recommended circuit-breaker Two-pole circuit-breaker from
Output overvoltage protection
(EC 898) in mains supply line 10 A, Characteristic C or from
6 A, Characteristic D Current limitation 3.8 A
Output Stabilized, floating direct voltage Short-circuit protection Stabilized current characteristic
to typ. 14 V, electronic shutdown
Rated voltage Vout rated 24 V DC
below that, automatic restart
Total tolerance ± 5 % (typ. ± 2 %)
RMS sustained short-circuit <4A
• Stat. mains compensation Approx. ± 0.1 % current
• Stat. load compensation Approx. ± 0.2 % Overload/short-circuit indicator -
Residual ripple (clock frequency: < 150 mVpp (typ. 30 mVpp) Safety
approx. 50 kHz)
Galvanic isolation pri- Yes, SELV output voltage Vout
Spikes (bandwidth: 20 MHz) < 240 mVpp (typ. 110 mVpp) mary/secondary acc. to EN 60950
Setting range - Protective class Class I
Status display - Discharge current < 3.5 mA
Power ON/OFF behavior No overshoot of Vout TÜV test Yes
(soft start)
CE-marking Yes
Starting delay/voltage rise < 1 s/typ. 80 ms
UL/cUL (CSA), approval Yes, cULus listed (UL 508, CSA
Rated current I out rated 3.5 A 22.2 No. 14-M91), File E143289
Current range FM approval -
• Up to +45 °C 0 to 3.5 A
Appr. for use in marine vessels -
• Up to +60 °C 0 to 3.5 A
Degree of protection (EN 60529) IP20
Dyn. V/I with
• Starting on short circuit typ. 5 A for 100 ms
• Short-circuit in operation typ. 5 A for 100 ms
Parallel connection for increased Yes, up to 5
output
■ Overview
Configuration
3 Configuring is carried out with the engineering software
SIMATIC WinCC flexible Micro, Compact, Standard or Advan-
ced (see HMI software/engineering software
SIMATIC WinCC flexible).
The necessary HardwareSupportPackage (HSP) can be down-
loaded free of charge via the following link:
http://www4.ad.siemens.de/WW/view/en/19241467
Importing of TP-Designer projects (TP 070) into WinCC flexible
is not possible.
A PC/PPI adaptor cable is needed to download the configura-
tion.
■ Technical specifications
Type TP 177micro Type TP 177micro
Display STN liquid crystal display (LCD) Functions 3
• Size 5.7" Message system
• Resolution (W x H in pixels) 320 x 240 (240 x 320 with vertical • No. of messages 500
design)
• Bit messages Yes
• Colors 4 blue levels
• Analog messages No
• MTBF backlighting (at 25 °C) Approx. 50,000 hours
• No. of process values per mes- 8
Control elements Touch screen sage
• Numeric/alphanumeric input Yes / Yes1) • Message buffer Circulating buffer, 128 entries
each 3)
Processor ARM CPU
Process diagrams 250
Memory
• Text objects 500 text elements
• Type Flash / RAM
• Variables per diagram 20
• Usable memory 256 KB
for user data • Entries per diagram 20
Ports 1 x RS 485 • Graphics objects Bitmaps, icons, background
images
Interface with PLC S7-200
• Dynamic objects Bars
Power supply 24 V DC
- Directories Yes
• Permitted range +18 V to +30 V DC
Variables 250
• Nominal current 0.24 A
User administration (security) Yes
Clock Software clock, without battery
backup Online languages 5
Degree of protection • Project languages (incl. system Danish, German, traditional Chi-
messages) nese, simplified Chinese, English,
• Front IP65 (in installed state), Finnish, French, Greek, Italian,
NEMA 4, NEMA 4x, NEMA 12 Japanese, Korean, Dutch, Norwe-
• Rear IP20 gian, Polish, Portuguese, Rus-
sian, Swedish, Spanish, Czech,
Certification Available soon: FM, cULus, CE, Turkish, Hungarian
C-Tick
Character set WinCC flexible, ideographic lan-
Dimensions guages
• Front W x H (mm) 212 x 156 Configuration tool From WinCC flexible 2004 Micro
• Cut-out W x H (mm) 198 x 142 HSP for OP 73micro, OP 73, OP
77A, TP 177micro, TP 177A (to be
Weight 0.7 kg ordered separately)
Ambient conditions • Configuration transfer Serial via RS 485
• Mounting position Vertical
- Max. permissible angle of incli- 2)
nation without forced ventilation
• Temperature
2)
- Operation (vertical installation) 0 °C to +50 °C
2)
- Operation (max. inclination)
- Transport, storage -20 °C to +60 °C
2)
• Max. relative humidity
1) English font only can be displayed
2) Status not yet established before going to print
3) Not battery-backed
Note:
All specified values are maximum values.
The total number of configurable elements is limited by the size of the user
memory.
■ Overview
• Operator panel for operator co ntrol and monitoring of small
machines and plants
• A new dimension in graphics: small and clever
3
• Pixel graphics 3" LCD, monochrome
• 8 system keys, 4 freely co nfigurable function keys
• Specifically for SIMATIC S7-200:
Communication with the controller is point-to-point using the
integral interface
• Connected to the PLC via MPI or PROFIBUS DP cable
• Start of delivery approximately end of 4th quarter 2004
■ Technical specifications
Type OP 73micro Type OP 73micro
Display LCD Ambient conditions
• Size 3“ • Mounting position Vertical
2)
• Resolution (W x H in pixels) 160 x 48 - max. permissible angle of
• Colors Monochrome (yellow-green) inclination without forced
ventilation
• MTBF of background lighting Approx. 100,000 hours
(at 25°C) • Temperature
- Operation (vertical installation) 0 °C to +50 °C
Control elements Membrane keyboard 2)
- Operation (max. inclination)
• Function keys, programmable 4 function keys
- Transport, storage -20 °C to +70 °C
• System keys 8 2)
• Max. relative humidity
• Numeric/alphanumeric input Yes/yes 1)
Functions
Processor ARM CPU
Message system
Memory • No. of messages 250
• Type Flash • Bit messages Yes
• Usable memory for user data 128 KB • Number of process values 8
Ports 1 x RS 485 per message
Interface with PLC S7-200 • Message buffer Circulating buffer, 128 entries
each 3)
Power supply 24 V DC Process diagrams 250
• Permitted range +18 to +30 V DC • Text objects 1000 text elements
• Nominal current 0.1 A • Variables per diagram 20
Clock Software clock, without battery • Fields per diagram 20
backup
• Graphics objects 250
Degree of protection • Dynamic objects Bars
• Front IP65 (in installed state) NEMA 12, - Directories Yes
NEMA 4x, NEMA4
Variables 500
• Rear IP20
User administration (security) Yes
Certification Available soon: FM, cULus, CE,
C-Tick Online languages 5
■ Overview
• Software for the SIMATIC S7-200
• Functions for all phases of an automation project:
- Planning, configuring and parameterization of hardware and
3
communication
- Creation of a user program
- Documentation
- Testing, commissioning and service
- Process control
- Archiving
The following are available:
• STEP 7- Micro/WIN
• STEP 7 Micro/WIN command library
• WinCC flexible micro
• S7-200 PC-Access
For further information see section 7.
Siemens ST 70 · 2005
SIMATIC S7-300
Introduction
S7-300/S7-300F
S7-300
• The modular mini PLC system for the low and medium perfor-
mance ranges
• With comprehensive range of modules for optimum adapta-
tion to the automation task
4 • Flexible use through simple implementation of distributed
structures and versatile networking
• Convenient system as result of user-friendly handling and
uncomplicated, fan-free configuration
• Can be expanded without prob lems when the tasks increase
• Powerful thanks to a large numb er of integrated functions
S7-300F
• Failsafe automation system for plants with increased safety
requirements for production engineering
• Based on S7-300
• ET 200S and ET 200M distributed I/O stations with safety-rel-
evant modules can also be connected; safety-relevant com-
munication via PROFIBUS DP with PROFISAFE profile.
• Standard modules can be used in addition for non-safety-rel-
evant applications
SIPLUS S7-300
• The PLC for use in the hars hest environmental conditions
• With extended temperature range from -25 to +70°C
• Suitable for extraordinary medi al load (pollution gas atmo-
sphere)
• Occasional short-term conden sation and increased mechani-
cal loading permissible
• With the proven PLC te chnology of the S7-300
• Convenient handling, programmi ng, maintenance and service
• Ideal for use in the automotive industry, environmental tech-
nology, mining, chemical plants, production technology, food
industry etc.
• The alternative to expe nsive custom solutions
More Information you can find at:
http://www.siemens.com/siplus
■ Technical specifications
General technical specifications S7-300, S7-300F General technical specifications SIPLUS S7-300
Degree of protection Degree of protection Ambient temperature
IP20 to IEC 60 529
Temperature Horizontal mounting:
Ambient temperature -25 °C to 70 °C
Vertical mounting:
• With horizontal mounting 0 to 60 °C -25 °C to 50 °C
• With vertical mounting 0 to 40 °C Relative humidity 5 to 95%; transient condensation 4
Relative humidity 5 to 95%, no condensation permissible, corresponding to
(RH severity level 2 in accor- relative humidity (RH-) stress
dance with IEC 61131-2) grade 2 according to IEC 1131-2
and IEC 721 3-3 Cl. 3K5
Atmospheric pressure 795 to 1080 hPa
Transient icing -25 °C to 0 °C
Isolation IEC 721 3-3 Cl. 3K5
• 24 V DC circuits Test voltage 500 V DC
Atmospheric pressure 1080 to 795 hPa corresponding to
• 230 V AC circuits Test voltage 1460 V AC a height of -1000 to 2000 m
Electromagnetic compatibility Requirements of EMC law; Pollutant concentration SO2: < 0,5 ppm; relative humidity
Noise immunity according <60% Test: 10 ppm, 4 days
to IEC 61000-6-2, H2S: < 0,1 ppm; relative humidity
tested according to: <60% Test: 1 ppm, 4 days
IEC 61000-4-2, (according to IEC 721 3-3;
61000-4-3, IEC 61000-4-4, Class 3C3)
IEC 61000-4-5, IEC 61000-4-6 Mechanical environmental
Emitted interference according conditions
to EN 50081-2, Vibrations Type of vibration: frequency
tested according to EN 55011, progressions changing at 1
class A, group 1 octave per minute. 2 Hz ≤ f ≤ 9 Hz,
Mechanical rating constant amplitude 3,0 mm
9 Hz ≤ f ≤ 150 Hz,
• Vibrations, tested according IEC 60068, Part 2-6/10 up 58 Hz; constant acceleration 1 g;
to/tested with constant amplitude 0.075 mm; Duration of vibration:
58 to 150 Hz; 10 frequency progressions per
constant acceleration 1 g; axis in each direction of the three
oscillation period: 10 frequency mutually perpendicular axes;
cycles per axis in each direction Vibration testing according to
of the 3 mutually perpendicular IEC 68 section 2-6 (Sinus) and
axes IEC 721 3-3, Class 3M4
• Shock, tested according IEC 60068, Part 2-27/half-sine: Shock Type of shock: semisinusoidal
to/tested with strength of impact 15 g shock strength: 15 g peak value,
(peak value), duration 11 ms duration shock direction 11 ms:
3 shocks each in +/- direction on
each of the mutually perpendicu-
lar axesShock testing according
to IEC 68 section 2-27
Conformity EN 50155
(railroad applications - electroni-
cal device on rail vehicles)
• The compact CPU with integrat ed digital inputs and outputs • The compact CPU with integr ated digital I/Os and second
• For small applications with high requirements in terms of pro- serial interface
cessing power • For installations with high requ irements in terms of processing
• With process-related functions power and response time.
• With process-related functions
Micro memory card required to operate the CPU.
Micro memory card required to operate the CPU.
• The compact CPU with integrated digital and analog inputs • The compact CPU with in tegrated digital I/Os and
and outputs PROFIBUS DP master/slave interface
• For installations with high requirements in terms of processing • With process-related functions
power and response time. • For tasks with special functions
• With process-related functions • For the connection of standalone I/O devices
Micro memory card required to operate the CPU. Micro memory card required to operate the CPU.
• The compact CPU with integrated digital and analog I/Os, as • The starter CPU for Totally Integrated Automation (TIA).
well as a second serial interface • For small-scale applications wi th moderate requirements on
• For installations with high requirements in terms of processing the processing speed.
power and response time
Micro memory card required to operate the CPU.
• With process-related functions
Micro memory card required to operate the CPU.
• The compact CPU with integrated digital and analog I/Os and • For installations with medium requirements on program scope
PROFIBUS DP master/slave interface • High processing performance in binary and floating-point
• With process-related functions arithmetic
• For tasks with special functions Micro memory card is required to operate the CPU.
• For the connection of standalone I/O devices
Micro memory card required to operate the CPU.
• The CPU with medium to larg e program memory and quantity • The CPU with a large program memory and PROFIBUS DP
framework for the use, if required, of SIMATIC Engineering Tools master/slave interface
• High processing performance in binary and floating-point • For extensive I/O configurations
arithmetic • For setting up distributed I/O structures
• PROFIBUS DP master/slave interface
• For extensive I/O configurations
• For setting up distributed I/O structures
Micro memory card required for operation of CPU.
• The CPU with a large program memory and quantity frame- • The CPU with a large program memory and quantity frame-
work for demanding requirements work for demanding requirements
• For multisector automation tasks in the construction of series • Distributed intelligence in Component based Automation
machines, special machines and plants (CBA) on PROFInet
• Used as a central controller on production lines with central • PROFINET proxy for intelligent devices on PROFIBUS DP in
and distributed I/O Component based Automation (CBA)
• High processing performance in binary and floating-point • PROFINET I/O controller for operating distributed I/O on
arithmetic PROFINET
• PROFIBUS DP master/slave interface • For multisector automation tasks in the construction of series
• For extensive I/O configurations machines, special machines and plants
• For setting up distributed I/O structures • Used as a central controller on production lines with central
and distributed I/O
• Supports as an option the use of SIMATIC Engineering Tools
• For extensive I/O configurations
• Distributed intelligence in Component based Automation
(CBA) on PROFIBUS DP • For setting up distributed I/O structures
• High processing performance in binary and floating-point
Micro memory card required for operation of CPU. arithmetic
• Combined MPI/PROFIBUS DP-master/slave interface
• Supports as an option the us e of SIMATIC Engineering Tools
Micro memory card required for operation of CPU.
4/6 Siemens ST 70 · 2005
SIMATIC S7-300
Central processing units
CPU 312C to CPU 317F-2 DP
• SIMATIC CPU with integrated technology/motion control func- • For configuration of a failsaf e automation system for plants
tionality with increased safety requirements
• With the full functionality of the standard CPU 317-2 DP • Based on the SIMATIC CPU 315-2 DP
• For multisector automation tasks in the construction of series • With 2 interfaces (1x MPI, 1x DP/MPI)
machines, special machines and plants • Complies with safety requiremen ts up to SIL 3 to IEC 61508,
• Ideal for synchronized motion al sequences such a coupling to AK6 to DIN V 19250 and Cat. 4 to EN 954-1
a virtual/real master, gearbox synchronism, cam disc or print- • Without additional wiring of safety-relevant I/O
mark correction.
• Safety-relevant communication via PROFIBUS DP with
• Used as a central controller on production lines with central PROFISAFE profile with distributed I/O stations
and distributed I/O
• Distributed connection of failsafe ET200S PROFISAFE I/O
• Distributed intelligence in Component Based Automation modules possible;
(CBA) on PROFIBUS DP Central and distributed connection of failsafe ET200M I/O
• With onboard I/O for fast tech nological functions (e.g., cam modules possible
switching, reference point detection) • Central and distributed use of standard modules for
• PROFIBUS DP (DRIVE) interfac e for the isochronous connec- non-safety-relevant applications
tion of drive components.
Micro memory card required for operation of CPU.
• A common S7 application program for control and motion
control tasks (no additional programming language for motion
control required)
• Optional "S7 Technology" package required
■ CPU 317F-2 DP
• The failsafe CPU with a large program memory and quantity
framework for demanding applications
• For configuration of a failsaf e automation system for plants
with increased safety requirements
• Complies with safety requiremen ts up to SIL 3 to IEC 61508,
4 AK6 to DIN V 19250 and Cat. 4 to EN 954-1
• Without additional wiring of the failsafe I/O
• 1x PROFIBUS DP master/slave interface and 1 x DP mas-
ter/slave/MPI interface
• Both interfaces can be used to integrate failsafe modules
• Distributed connection of failsafe ET200S PROFIsafe I/O
modules possible;
Central and distributed connection of failsafe ET200M I/O
modules possible
• Central and distributed use of standard modules for
non-safety-relevant applications
Micro memory card required for operation of CPU.
■ Technical specifications
6ES7 312- 6ES7 313- 6ES7 313- 6ES7 313- 6ES7 314- 6ES7 314-
5BD01-0AB0 5BE01-0AB0 6BE01-0AB0 6CE01-0AB0 6BF01-0AB0 6CF01-0AB0
Product version
• Associated programming STEP 7 as of STEP 7 as of STEP 7 as of STEP 7 as of STEP 7 as of STEP 7 as of
package 5.2 + SP 1 5.2 + SP 1 of 5.2 + SP 1 of 5.2 + SP 1 as of 5.2 + SP 1 of 5.2 + SP 1
(for STEP 7 as of (for STEP 7 as of (for STEP 7 as of (for STEP 7 as of
5.1 + SP 3 5.1 + SP 3 5.1 + SP 3 5.1 + SP 3
please use please use please use please use
previous CPU previous CPU previous CPU previous CPU
version) version) version) version)
Supply voltages
Rated value
- 24 V DC Yes Yes Yes Yes Yes Yes
- permissible range, 20.4 V 20.4 V 20.4 V 20.4 V 20.4 V 20.4 V
lower limit (DC)
- permissible range, 28.8 V 28.8 V 28.8 V 28.8 V 28.8 V 28.8 V
upper limit (DC)
Current consumption
• Inrush current, typ. 11 A 11 A 11 A 11 A 11 A 11 A
• from supply voltage L+, max. 500 mA 700 mA 700 mA 900 mA 800 mA 1,000 mA
• Power dissipation, typical 6W 14 W 10 W 10 W 14 W 14 W
Memory/backup
Memory
• Working memory
- integral 16 KByte; 32 KByte; 32 KByte; 32 KByte; 48 KByte; 48 KByte;
for program for program for program for program for program for program
and data and data and data and data and data and data
- expandable No No No No No No
• Load memory
- pluggable (MMC) Yes Yes Yes Yes Yes Yes
- pluggable (MMC), max. 4 MByte 8 MByte 8 MByte 8 MByte 8 MByte 8 MByte
Backup
- available Yes; guaran- Yes; guaran- Yes; guaran- Yes; guaran- Yes; guaran- Yes; guaran-
teed by MMC teed by MMC teed by MMC teed by MMC teed by MMC teed by MMC
(maintenance- (maintenance- (maintenance- (maintenance- (maintenance- (maintenance-
free) free) free) free) free) free)
- without battery Yes; Program Yes; Program Yes; Program Yes; Program Yes; Program Yes; Program
and data and data and data and data and data and data
- Size, max.
DB 0 reserved
16 KByte
DB 0 reserved
16 KByte
DB 0 reserved
16 KByte
DB 0 reserved
16 KByte
DB 0 reserved
16 KByte
DB 0 reserved
16 KByte
4
FB
- Number, max. 512; from 512; from 512; from 512 512 512
FB 0 to FB 511 FB 0 to FB 511 FB 0 to FB 511
- Size, max. 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte
FC
- Number, max. 512; from 512; from 512; from 512 512 512
FC 0 to FC 511 FC 0 to FC 511 FC 0 to FC 511
- Size, max. 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte
OB
- Number, max. See instruction See instruction See instruction See instruction See instruction See instruction
list list list list list list
- Size, max. 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte
Nesting depth
- per priority class 8 8 8 8 8 8
- additional levels within an 4 4 4 4 4 4
error OB
CPU/processing times
• for bit instruction, min. 0.2 µs 0.1 µs 0.1 µs 0.1 µs 0.1 µs 0.1 µs
• for word instruction, min. 0.4 µs 0.2 µs 0.2 µs 0.2 µs 0.2 µs 0.2 µs
• for integer math, min. 5 µs 2 µs 2 µs 2 µs 2 µs 2 µs
• for floating-point math, min. 6 µs 3 µs 3 µs 3 µs 3 µs 3 µs
Timers/counters and their
retentive characteristics
S7 counter
- Number 128 256 256 256 256 256
• of which retentive without battery
- adjustable Yes Yes Yes Yes Yes Yes
- lower limit 0 0 0 0 0 0
- upper limit 128 256 256 256 256 256
• Retentivity
- adjustable Yes
• Counting range
- lower limit 0 0 0 0 0 0
- upper limit 999 999 999 999 999 999
IEC counter
- available Yes Yes Yes Yes Yes Yes
- Type SFB SFB SFB SFB SFB SFB
S7 times
- Number 128 256 256 256 256 256
• Retentivity
- adjustable Yes Yes Yes Yes Yes Yes
- lower limit 0 0 0 0 0 0
- upper limit 128 256 256 256 256 256
- preset No retention No retention No retention No retention No retention No retention
• Timing range
- lower limit 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms
- upper limit 9,990 s 9,990 s 9,990 s 9,990 s 9,990 s 9,990 s
IEC timer
- available Yes Yes Yes Yes Yes Yes
- Type SFB SFB SFB SFB SFB SFB
4 - Number
- adjustable retentivity
128 Byte
Yes; MB 0
256 Byte
Yes; MB 0
256 Byte
Yes; MB 0
256 Byte
Yes; MB 0
256 Byte
Yes; MB
256 Byte
Yes; MB 0
to MB 127 to MB 255 to MB 255 to MB 255 to MB 255 to MB 255
- Number of clock memories 8; 8; 8; 8 8 8
1 memory byte 1 memory byte 1 memory byte
Data blocks
- Number, max. 511; from DB 1 511; from DB 1 511; from DB 1 511 511 511
to DB 511 to DB 511 to DB 511
- Size, max. 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte 16 KByte
Local data
- per priority class, max. 256 Byte 510 Byte 510 Byte 510 Byte 510 Byte
Address area
I/O address area
- Inputs 1 KByte 1 KByte 1 KByte 1 KByte 1 KByte 1 KByte
- Outputs 1 KByte 1 KByte 1 KByte 1 KByte 1 KByte 1 KByte
Process image
- Inputs 128 Byte 128 Byte 128 Byte 128 Byte 128 Byte 128 Byte
- Outputs 128 Byte 128 Byte 128 Byte 128 Byte 128 Byte 128 Byte
Digital channels
- Inputs 256 992 1.008 8.192 992 992
- Outputs 256 992 1.008 8.192 992 992
- Inputs, of which central 256 992 992 992 992 992
- Outputs, of which central 256 992 992 992 992 992
Analog channels
- Inputs 64 248 248 248 253 512
- Outputs 32 124 124 124 124 124
- Inputs, of which central 248 248 248 248 248
- Outputs, of which central 248 248 248 248 248
Configuration
• Central units, max. 1 1 1 1 1 1
• Expansion units, max. 0 3 3 3 3 3
• Racks, max. 1 4 4 4 4 4
• Modules per rack, max. 8 8; 8; 8; 8; 8;
in rack 3 max. 7 in rack 3 max. 7 in rack 3 max. 7 in rack 3 max. 7 in rack 3 max. 7
Number of DP masters
- integral No No No 1 1
- via CP 1 2 1 1 1 1
Number of FMs and CPs that can
be operated (recommendation)
- FM 8 8 8 8 8 8
- CP, point-to-point 8 8 8 8 8 8
- CP, LAN 4 6 6 6 10 10
4 - Outputs, max.
• User data per DP Slave
1 KByte 1 KByte
Supply voltages
4
Rated value
- 24 V DC Yes Yes Yes Yes Yes
- permissible range, 20.4 V 20.4 V 20.4 V 20.4 V 20.4 V
lower limit (DC)
- permissible range, 28.8 V 28.8 V 28.8 V 28.8 V 28.8 V
upper limit (DC)
Voltages and currents
• External fusing for supply lines Min. 2 A Min. 2 A Min. 2 A Min. 2 A LS switch; 2 A,
(recommendation) Type B or C
Current consumption
• Inrush current, max. 12 A
• Inrush current, typ. 2.5 A 2.5 A 2.5 A 2.5 A 8A
• I²t 0.5 A²s 0.5 A²s 0.5 A²s 1 A²s
• from supply voltage L+, max. 600 mA 600 mA 800 mA
• Power dissipation, typical 2.5 W 2.5 W 2.5 W 4W 12 W
Memory/backup
Memory
• Working memory
- integral 16 KByte 48 KByte 128 KByte 512 KByte 512 KByte
- expandable No No No No
• Load memory
- pluggable (MMC) Yes Yes Yes Yes
- pluggable (MMC), max. 4 MByte 8 MByte 8 MByte 8 MByte
- expandable FEPROM Yes
- expandable FEPROM, max. 4 MByte
- integral RAM, max. 64 KByte
- expandable RAM Yes
- expandable RAM, max 2 MByte
Backup
- available Yes; guaranteed Yes; guaranteed Yes; guaranteed Yes; guaranteed Yes
by MMC (mainte- by MMC (mainte- by MMC (mainte- by MMC (mainte-
nance-free) nance-free) nance-free) nance-free)
- with battery Yes; all blocks
- without battery Yes; 11 KByte
4 - Software clock
- buffered
Yes
No Yes Yes Yes Yes
- Deviation per day, max 15 s 10 s 10 s 10 s 10 s
Run-time meter
- Quantity 1 1 1 4 8
- Number 0 0 0 0 to 3 0 to 7
- Range of values 0 to 231 hours (when 0 to 231 hours (when 0 to 231 hours (when 0 to 231 hours (when 0 to 32767 hours
using SFC 101) using SFC 101) using SFC 101) using SFC 101)
- Granularity 1 hour 1 hour 1 hour 1 hour 1 hour
- retentive Yes; must be Yes; must be Yes; must be Yes; must be Yes
restarted on each restarted on each restarted on each restarted on each
complete restart complete restart complete restart complete restart
Time synchronization
- supported Yes Yes Yes Yes Yes
- on MPI, master Yes Yes Yes Yes Yes
- on MPI, slave Yes Yes Yes Yes Yes
- in AS, master Yes Yes Yes Yes Yes
- in AS, slave Yes Yes
S7 message functions
• Number of stations that can log on 6; depending on the 12; depending on 16; depending on 32; depending on
for message functions, max. connections config- the connections the connections the connections
ured for PG/OP and configured for configured for configured for
S7 basic communi- PG/OP and S7 PG/OP and S7 PG/OP and S7
cation basic communica- basic communica- basic communica-
tion tion tion
• Process diagnostic messages Yes Yes Yes Yes Yes
• simultaneously active Alarm-S 20 40 40 60 100
blocks, max.
Test and startup functions
Status/modify
- Variable Yes Yes Yes Yes Yes
- Variables Inputs, outputs, Inputs, outputs, Inputs, outputs, Inputs, outputs, Inputs, outputs,
flags, DB, timers, flags, DB, timers, flags, DB, timers, flags, DB, timers, flags, DB, timers,
counters counters counters counters counters
- Number of variables, max. 30 30 30 30 70
- of which status variables, max. 30 30 30 30
- of which modify variables, max. 14 14 40 14
Forcing
- Forcing Yes Yes Yes Yes Yes
- Forcing, variables Inputs, Inputs, Inputs, Inputs, Inputs, outputs,
outputs outputs outputs outputs memory markers,
distributed inputs,
distributed outputs
- Forcing, number of variables, 10 10 10 10 256
max.
• Status block Yes Yes Yes Yes Yes
• Single step Yes Yes Yes Yes Yes
• Number of breakpoints 2 2 2 2 4
Diagnostic buffer
- available Yes Yes Yes Yes Yes
- Number of inputs, max. 100 100 200 100 100
- adjustable No No No No No
4 - PG/OP communication
- Routing
Yes
Yes
Yes
• Intermediate memory
- Inputs 244 Byte 244 Byte 244 Byte
- Outputs 244 Byte 244 Byte 244 Byte
- Address areas, max. 32 32
- User data per address area, max. 32 Byte 32 Byte
4 - LAD
- FBD
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
- STL Yes Yes Yes Yes Yes
- SCL Yes Yes Yes Yes
- CFC Yes
- GRAPH Yes Yes Yes
- HiGraph® Yes Yes Yes
Software library
- Process diagnostics Yes
- Software controller Yes
• Instruction set see instruction list see instruction list see instruction list see instruction list see instruction list
• Bracket levels 8 8 8 8 8
• User program protection/pass- Yes Yes Yes Yes Yes
word protection
• System functions (SFC) see instruction list see instruction list see instruction list see instruction list see instruction list
• System function blocks (SFB) see instruction list see instruction list see instruction list see instruction list see instruction list
Dimensions and weight
• Weight, approx. 270 g 280 g 290 g 460 g 930 g
• Width 40 mm 40 mm 40 mm 80 mm 160 mm
• Height 125 mm 125 mm 125 mm 125 mm 125 mm
• Depth 130 mm 130 mm 130 mm 130 mm 130 mm
4 • Services
- PG/OP communication Yes
• Services
- PG/OP communication Yes Yes
- Routing Yes
- Routing Yes; with active Yes; with active
- Global data communication No interface interface
- S7 basic communication No - Global data communication No No
- S7 communication No - S7 basic communication No No
- Equidistance support Yes - S7 communication, as client No No
- SYNC/FREEZE Yes - S7 communication, as server No No
- DPV1 Yes - Direct data exchange Yes Yes
- Transmission rates, max. 12 Mbit/s (lateral communication)
- Number of DP slaves, max. 125 - DPV1 No No
• Address area - GSD file http://www.ad. http://www.ad.
- Inputs, max. siemens.com/ siemens.com/
244 KByte
csi_e/gsd csi_e/gsd
- Outputs, max. 244 KByte
- Transmission rates, max. 12 Mbit/s 12 Mbit/s
2nd interface • Intermediate memory
• Type of interface integrated RS integrated RS - Inputs 244 Byte 244 Byte
485 interface 485 interface - Outputs 244 Byte 244 Byte
• Physical RS 485 RS 485 - Address areas, max. 32 32
• Isolated Yes Yes - User data per address area, 32 Byte 32 Byte
max.
• Power supply to interface 200 mA 200 mA
(15 to 30 V DC), max. CPU/ programming
Functionality Programming language
- MPI No No - STEP 7 Yes; as of V5.1 Yes; STEP 7 as
- DP master Yes Yes SP6 of V 5.2 + SP1
- DP slave S7 Distributed
Yes Yes Safety as of
- Point-to-point connection No No V5.2 SP1
DP master - LAD Yes Yes
- Number of connections, max. 16 32 - FBD Yes Yes
- STL Yes Yes
• Services
- SCL Yes Yes
- PG/OP communication Yes Yes
- Routing Yes Yes Software library
- Global data communication No No • Instruction set See instruction See instruction
list list
- S7 basic communication No No
• Bracket levels 8 8
- S7 communication No No
- Equidistance support • User program protection/pass- Yes Yes
Yes Yes
word protection
- SYNC/FREEZE Yes Yes
• System functions (SFC) See instruction See instruction
- DPV1 Yes Yes list list
- Transmission rates, max. 12 Mbit/s 12 Mbit/s • System function blocks (SFB) See instruction See instruction
- Number of DP slaves, max. 125 125 list list
• Address area
- Inputs, max. 244 KByte 244 KByte
- Outputs, max. 244 KByte 244 KByte
SIMATIC Manual Collection B) 6ES7 998-8XC01-8YE0 SIMATIC S7 Demo Case 6ES7 910-3AA00-0XA0
• The compact CPU with integrat ed digital inputs and outputs • For installations with medium requirements on program scope
• For small applications with hi gh requirements in terms of • High processing performance in binary and floating-point
processing power arithmetic
• With process-related functions Micro memory card is required to operate the CPU.
Micro memory card required to operate the CPU. • These modules are designed for
• These modules are designed for • an ambient range of – 25 °C to + 70 °C, condensation
permissible.
• an ambient range of – 25 °C to + 70 °C, condensation permis-
sible. • extraordinary medial load (for example by chloric and sulphu-
ric atmospheres).
• extraordinary medial load (for example by chloric and sulphu-
ric atmospheres).
• The compact CPU with integrated digital and analog inputs • The CPU with medium to large program memory and quantity
and outputs framework for the use, if required, of SIMATIC Engineering
• For installations with high requirements in terms of processing Tools
power and response time. • High processing performance in binary and floating-point
• With process-related functions arithmetic
• PROFIBUS DP master/slave interface
Micro memory card required to operate the CPU.
• For extensive I/O configurations
• These modules are designed for
• For setting up distributed I/O structures
• an ambient range of – 25 °C to + 70 °C, condensation permis-
sible. Micro memory card is required to operate the CPU.
• extraordinary medial load (for example by chloric and sulphu- These modules are designed for
ric atmospheres).
• an ambient range of – 25 °C to + 70 °C, condensation permis-
sible.
• extraordinary medial load (for example by chloric and sulphu-
ric atmospheres).
■ Overview
• Digital inputs
• For connecting standard swit ches and two-wire proximity
switches (BERO)
■ Technical specifications
6ES7 321-1BH02-0AA0 6ES7 321-1BH50-0AA0 6ES7 321-1BL00-0AA0 6ES7 321-1BH10-0AA0
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V 24 V 24 V 24 V
Current consumption
• from load voltage L+ (no load), 25 mA
max.
• from backplane bus 5 V DC, max. 10 mA 10 mA 15 mA 110 mA
• Power dissipation, typical 3.5 W 3.5 W 6.5 W 3.8 W
Connection system
• Requisite front connector 20-pin 20-pin 40-pin 20-pin
Clock synchronism
• Clock synchronous operation No No No Yes
Digital inputs
• Number of digital inputs 16 16 32 16
Number of inputs that can be driven
in parallel
• vertical mounting positions
- up to 40°C 16 16 32 16
• horizontal mounting positions
- up to 40°C 32
- up to 60°C 16 16 16 16
Length of cable
- Length of cable shielded, max. 1,000 m 1,000 m 1,000 m 1,000 m
- Length of cable unshielded, 600 m 600 m 600 m 600 m
max.
• Input characteristic to comply Yes Yes Yes Yes
with IEC 1131, Type 1
Input voltage
- Rated value, DC 24 V 24 V 24 V 24 V
- for signal "0" -30 V to 5 V 30 V to -5V -30 to 5 V -30 V to 5 V
- for signal "1" 13 to 30 V -13 to -30 V 13 to 30 V 13 to 30 V
Input current
- for 1 signal, typical 7 mA 7 mA 7 mA 7 mA
Input delay (at rated value of the
input voltage)
• For standard inputs
- at 0 to 1, min. 1.2 ms 1.2 ms 1.2 ms 25 µs
- at 0 to 1, max. 4.8 ms 4.8 ms 4.8 ms 75 µs
■ Overview
• Digital outputs
• For connecting solenoid valv es, contactors, low-power mo-
tors, lamps and motor starters
■ Technical specifications
6ES7 322- 6ES7 322- 6ES7 322- 6ES7 322- 6ES7 322- 6ES7 322-
1BH01-0AA0 1BH10-0AA0 1BL00-0AA0 8BF00-0AB0 5GH00-0AB0 1CF00-0AA0
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V 24 V 24 V 24 V 24 V; 24/48 48 V; DC 48
to 125 V
Current consumption
• from load voltage L+ (no load), 80 mA 110 mA 160 mA 90 mA 200 mA 2 mA
max.
• from backplane bus 5 V DC, max. 80 mA 70 mA 110 mA 70 mA 100 mA 100 mA
• Power dissipation, typical 4.9 W 5W 6.6 W 5W 2.8 W 7.2 W
Connection system
• Requisite front connector 20-pin 20-pin 40-pin 20-pin 40-pin 20-pin
Digital outputs
• Number of digital outputs 16 16 32 8 16 8
• Length of cable shielded, max. 1,000 m 1,000 m 1,000 m 1,000 m 1,000 m 1,000 m
• Length of cable unshielded, max. 600 m 600 m 600 m 600 m 600 m 600 m
• Short-circuit protection of the Yes; electronic Yes; electronic Yes; electronic Yes; electronic No; provided Yes; electronic
output externally
• Limitation of voltage induced on L+ (-53 V) L+ (-53 V) L+ (-53 V) L+ (-45 V) M (-1V)
circuit interruption to
• Lamp load, max. 5W 5W 5W 5W 2.5 W 15 W;
15 W (48 V) or
40 W (125 V)
Output voltage
- for 1 signal L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V) L+ (-0.8 V L+ (-0.25 V) L+ (-1.2V)
to -1.6 V)
Output current
- for 1 signal rated value 0.5 A 0.5 A 0.5 A 0.5 A 0.5 A 1.5 A
- for 1 signal permissible range 5 mA 5 mA 5 mA 10 mA 10 mA
for 0 to 40 °C, min.
- for 1 signal permissible range 0.6 A 0.6 A 0.6 A 0.6 A 1.5 A
for 0 to 40 °C, max.
- for 1 signal permissible range 5 mA 5 mA 5 mA 10 mA 10 mA
for 40 to 60 °C, min.
- for 1 signal permissible range 0.6 A 0.6 A 0.6 A 0.6 A 1.5 A
for 40 to 60 °C, max.
- for 1 signal minimum load 5 mA 5 mA 5 mA 10 mA 10 mA
current
- for 1 signal permissible surge 1.5 A; for 50 ms, 3 A; for 10 ms
current, max. 1 A2s one-off
- for 0 signal residual current, max. 0.5 mA 0.5 mA 0.5 mA 0.5 mA 10 µA 0.5 mA
6ES7 322- 6ES7 322- 6ES7 322- 6ES7 322- 6ES7 322- 6ES7 322-
1BF01-0AA0 1FF01-0AA0 5FF00-0AB0 1FH00-0AA0 1FL00-0AA0 1HF01-0AA0
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V 24 V
Load voltage L1
- Rated value (AC) 230 V; AC 230 V; AC 230 V; AC 120 V; AC
120/230 V 120/230 V 120/230 V 120/230 V
Current consumption
• from load voltage L+ (no load), 60 mA 2 mA 110 mA;
max. Relay current
consumption
■ Overview
• Digital inputs and outputs
• For connecting standard switches, two-wire proximity
switches (BERO), solenoid valves, contactors, low-power
motors, lamps and motor starters
■ Technical specifications
6ES7 323-1BH01-0AA0 6ES7 323-1BL00-0AA0 6ES7 327-1BH00-0AB0
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V 24 V 24 V
Current consumption
• from load voltage L+ (no load), 40 mA 80 mA 20 mA
max.
• from backplane bus 5 V DC, max. 40 mA 80 mA 60 mA
• Power dissipation, typical 3.5 W 6.5 W 3W
Connection system
• Requisite front connector 20-pin 40-pin 20-pin
Clock synchronism
• Clock synchronous operation No No No
Digital inputs
• Number of digital inputs 8 16 8; 8 hard-wired and 8 more for
individual parameter assignment
Number of inputs that can be driven
in parallel
- Number of inputs that can be 8 16 16
driven in parallel, up to 40 °C
- Number of inputs that can be 8 8 16
driven in parallel, up to 60 °C
Length of cable
- Length of cable shielded, max 1,000 m 1,000 m 1,000 m
- Length of cable unshielded, max 600 m 600 m 600 m
• Input characteristic to comply with Yes Yes Yes
IEC 1131, Type 1
Input voltage
- Rated value, DC 24 V 24 V 24 V
- for signal "0" -30 to 5 V -30 to 5 V -30 to 5 V
- for signal "1" 13 to 30 V 13 to 30 V 15 to 30 V
Input current
- for 1 signal, typical 7 mA 7 mA 6 mA
Input delay (at rated value of the
input voltage)
• For standard inputs
- at 0 to 1, min. 1.2 ms 1.2 ms 1.2 ms
- at 0 to 1, max. 4.8 ms 4.8 ms 4.8 ms
- at 1 to 0, min 1.2 ms 1.2 ms 1.2 ms
- at 1 to 0, max. 4.8 ms 4.8 ms 4.8 ms
These modules are designed for Accessories see ordering data for
S7-300 digital input modules
• an ambient range of – 25 °C to + 70 °C,
condensation permissible. A) Subject to export regulations: AL: N and ECCN: EAR99H
• extraordinary medial load
(for example by chloric and sulphuric atmospheres).
■ Overview
• Analog inputs
• For connection of volt age and current sensors,
thermocouples, resistors and resistance thermometers
■ Technical specifications
6ES7 331-7KF02-0AB0 6ES7 331-7HF01-0AB0 6ES7 331-1KF01-0AB0 6ES7 331-7KB02-0AB0
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V 24 V 24 V
- Reverse polarity protection Yes Yes Yes
Current consumption
• from load voltage L+ (no load), 200 mA 50 mA 80 mA
max.
• from backplane bus 5 V DC, max. 50 mA 60 mA 90 mA 50 mA
• Power dissipation, typical 1W 1.5 W 0.4 W 1.3 W
Connection system
• Requisite front connector 20-pin 20-pin 40-pin 20-pin
Clock synchronism
• Clock synchronous operation No Yes No No
Analog inputs
• Number of analog inputs 8 8 8 2
• Number of analog inputs for resis- 4 8 1
tance measurement
• Length of cable shielded, max. 200 m; 50 m at 80 mV 200 m 200 m; 200 m; 50 m at 80 mV
and thermocouples max. 50 m at 50 mV and thermocouples
• Permissible input voltage for the 20 V; permanent; 20 V; 20 V permanent, 30 V; 12 V continuous, 20 V; permanent;
voltage input (destruction limit), 75V for max. 1s 75 V for max. 1 s 30 V for max. 1 s 75V for max. 1s
max. (pulse duty ratio 1:20) (pulse duty ratio 1:20) (pulse duty ratio 1:20)
• Permissible input voltage for the 40 mA 40 mA 40 mA 40 mA
current input (destruction limit),
max.
Input ranges (rated values),
voltages
- 0 to +10 V Yes
- 1 to +5 V Yes Yes Yes Yes
- 1 to +10 V Yes No
- -1 V to +1 V Yes Yes Yes Yes
- -10 V to +10 V Yes Yes Yes Yes
- -2.5 V to +2.5 V Yes No Yes
- -250 mV to +250 mV Yes No Yes
- -5 V to +5 V Yes Yes Yes Yes
- -50 mV to +50 mV Yes
- -500 mV to +500 mV Yes Yes Yes
- -80 mV to +80 mV Yes Yes
4 - -10 to +10 mA
- -20 to +20 mA
Yes
Yes Yes Yes
Yes
Yes
- -3.2 to +3.2 mA Yes Yes
- 4 to 20 mA Yes Yes Yes Yes
Input ranges (rated values),
thermocouples
- Type E Yes Yes
- Type J Yes Yes
- Type K Yes Yes
- Type N Yes Yes
Input ranges (rated values),
resistances
- 0 to 150 ohms Yes Yes
- 0 to 300 ohms Yes Yes
- 0 to 600 ohms Yes Yes Yes
- 0 to 6000 ohms Yes
Input ranges (rated values),
resistance thermometer
- Ni 100 Yes; Standard Yes; Standard/climate Yes
- LG-Ni 1000 Yes; Standard/climate
- Pt 100 Yes; Standard Yes; Standard/climate Yes
Characteristic curve linearization
- parameterizable Yes Yes Yes
- for thermocouples Type N, E, J, K, L Type N, E, J, K, L
- for resistance thermometer Pt 100 (standard range, yes; Pt100 standard/cli- Pt 100 (standard range,
climatic range), Ni 100 matic; Ni100 standard/cli- climatic range), Ni 100
(standard range, climatic matic; Ni1000 (standard range, climatic
range) standard/climatic; LG- range)
Ni1000 standard/climatic
Temperature compensation
- parameterizable Yes Yes
- external temperature compen- Yes Yes
sation with compensating box
possible
- internal temperature compen- Yes Yes
sation possible
Analog value formation
• Measuring principle integrating Conversion of instanta- integrating integrating
neous values
Integration and conversion
time/triggering per channel
- with over-range 15 Bit; unipolar: 14 Bit; 13 Bit 15 Bit; unipolar:
(bits incl. sign), max. 9 / 12 / 12 / 14 bits, unipolar: 14 bits; 9 / 12 / 12 / 14 bits,
bipolar: 9 + VZ/12 + bipolar: 13+VZ bits bipolar: 9 + VZ/12 +
VZ/12 + VZ/14 + VZ bits VZ/12 + VZ/14 + VZ bits
- Integration time Yes; Yes Yes; Yes;
parameterizable 2.5 / 16.67 / 20 / 100 ms 60 / 50 ms 2.5 / 16.67 / 20 / 100 ms
- Basic conversion time incl. 3/ 17/ 22/ 102 ms 66 / 55 ms 6/ 34/ 44/ 204 ms
integration time, ms
- Basic conversion time, ms 52 µs per channel 66 / 55 ms
- Interference voltage suppressi- 400 / 60 / 50 / 10 Hz 400 / 60 / 50 / 10 Hz 50 / 60 Hz 400 / 60 / 50 / 10 Hz
on for interference frequency f1
in Hz
40-pin, with spring-loaded termi- 6ES7 392-1BM01-0AA0 SIMATIC Manual Collection 6ES7 998-8XC01-8YE2
nals update service for 1 year B)
SIMATIC TOP connect see page 4/157 Configuration, CPU data, module
data, command list
Bus connectors 6ES7 390-0AA00-0AA0
German 6ES7 398-8FA10-8AA0
1 item (spare part)
English 6ES7 398-8FA10-8BA0
Shield attachment 6ES7 390-5AA00-0AA0
French 6ES7 398-8FA10-8CA0
80 mm wide, with 2 rows each for
4 shield connection terminals Spanish 6ES7 398-8FA10-8DA0
Terminal elements Italian 6ES7 398-8FA10-8EA0
2 items
For 2 cables 6ES7 390-5AB00-0AA0
2 to 6 mm in diameter
For 1 cable 6ES7 390-5BA00-0AA0
3 to 8 mm in diameter
For 1 cable 6ES7 390-5CA00-0AA0
4 to 13 mm in diameter
Label cover 6ES7 392-2XY00-0AA0
10 items for signal modules
(not 32-channel),
function modules
A) Subject to export regulations: AL: N and ECCN: EAR99H
B) Subject to export regulations: AL: N and ECCN: EAR99S
■ Overview
• Analog outputs
• For the connection of analog actuators
■ Technical specifications
6ES7 332-5HB01-0AB0 6ES7 332-5HD01-0AB0 6ES7 332-5HF00-0AB0 6ES7 332-7ND01-0AB0
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V 24 V 24 V 24 V
Current consumption
• from load voltage L+ (no load), 135 mA 240 mA 340 mA 240 mA
max.
• from backplane bus 5 V DC, max. 60 mA 60 mA 100 mA 100 mA
• Power dissipation, typical 3W 3W 6W 3W
Connection system
• Requisite front connector 20-pin 20-pin 40-pin 20-pin
Analog outputs
• Number of analog outputs 2 4 8 4; isochrone mode
• Length of cable shielded, max. 200 m 200 m 200 m 200 m
• Voltage output, short-circuit Yes Yes Yes Yes
protection
• Voltage output, short-circuit 25 mA 25 mA 25 mA 40 mA
current, max
• Current output, open-circuit 18 V 18 V 18 V 18 V
voltage, max.
Output ranges, voltage
- 0 to 10 V Yes Yes Yes Yes
- 1 to 5 V Yes Yes Yes Yes
- -10 to +10 V Yes Yes Yes Yes
Output ranges, current
- 0 to 20 mA Yes Yes Yes Yes
- -20 to +20 mA Yes Yes Yes Yes
- 4 to 20 mA Yes Yes Yes Yes
Burden resistance (in the nominal
output range)
- at voltage outputs, min. 1 kΩ 1 kΩ 1 kΩ 1 kΩ
- at voltage outputs, capacitive 1 µF 1 µF 1 µF 1 µF
load, max.
- at current outputs, max. 500 Ω 500 Ω 500 Ω 500 Ω
- at current outputs, inductive 10 mH 10 mH 10 mH 1 mH
load, max.
■ Overview
• Analog inputs and outputs
• For the connection of ana log sensors and actuators
■ Technical specifications
6ES7 334- 6ES7 334- 6ES7 334- 6ES7 334-
0CE01-0AA0 0KE00-0AB0 0CE01-0AA0 0KE00-0AB0
Voltages and currents Analog outputs
Load voltage L+ • Number of analog outputs 2 2
- Rated value (DC) 24 V 24 V • Length of cable shielded, max 200 m 100 m
Current consumption • Voltage output, short-circuit Yes Yes
• from load voltage L+ (no load), 110 mA 80 mA protection
max. 11 mA 10 mA
• Voltage output, short-circuit
• from backplane bus 5 V DC, max. 55 mA 60 mA current, max
• Power dissipation, typical 3W 2W • Current output, open-circuit 15 V
Connection system voltage, max.
• Requisite front connector 20-pin 20-pin Output ranges, voltage
Analog inputs - 0 to 10 V Yes Yes
• Number of analog inputs 4 4 Output ranges, current
• Number of analog inputs for 4 2 - 0 to 20 mA Yes
voltage measurement
Burden resistance (in the nominal
• Number of analog inputs for 4 output range)
resistance measurement - at voltage outputs, min. 5 kΩ 2.5 kΩ
• Permissible input voltage for the 20 V; 20 V; - at voltage outputs, 1 µF 1 µF
voltage input (destruction limit), max. 20V con- permanent; capacitive load, max.
max. tinuous; 75V for 75 V for max.
- at current outputs, max. 300 Ω
max. 1s (pulse 1s (pulse duty
duty ratio 1:20) ratio 1:20) - at current outputs, 1 mH
inductive load, max.
• Permissible input voltage for the 40 mA
current input (destruction limit), Analog value formation
max.
Integration and conversion
• Cycle time (all channels) 5 ms; AE+AA 85 ms time/triggering per channel
Input ranges (rated values), - with over-range (bits incl. sign), 8 Bit 12 Bit
voltages max
- 0 to +10 V Yes Yes - Integration time, ms 16,67; 20
Input ranges (rated values), Settling time
currents - for resistive load 0.3 ms 0.8 ms
- 0 to 20 mA Yes - for capacitive load 3 ms 0.8 ms
Input ranges (rated values), - for inductive load 0.3 ms
resistances
- 0 to 10000 ohms Yes
Input ranges (rated values),
resistance thermometer
- Pt 100 Yes; climatic
range only
■ Overview
• High-speed analog inputs and outputs for the SIMATIC
S7-300
• For the connection of ana log sensors and actuators
• The SM 335 fast analog in put/output module provides:
• 4 fast analog inputs
4 (basic conversion time for 4 channels max. 1 ms)
• 4 fast analog outputs
(conversion max. 0.8 ms per channel)
• Encoder power supply 10 V/25 mA
• 1 counter input (24 V/500 Hz)
• The SM 335 has two special modes:
• Comparator: In this mode the SM 335 compares a setpoint
value with an analog value measured at the analog input.
Application: very fast comparison of an analog value
• Measurement only: In the „measurement only“ mode, the
analog inputs are measured continually without updating the
analog outputs.
Application: very fast measurement of analog values
(< 0.5 ms)
■ Technical specifications
Module-specific data Analog inputs
Number of inputs 4 Interference between inputs
Number of outputs 4 • at 50 Hz 65 dB
Cable length, shielded 200 m • at 60 Hz 65 dB
With wire-break monitoring in range 30 m Operational limits
0 V ... 10 V (over entire temperature range,
referred to input range)
Voltages, currents, potentials
• with voltage measurement ± 0.15% (with 14-bit resolution)
Rated load voltage 24 V DC
• with current measurement 0.25%
Polarity reversal protection yes
Basic error limit 0.13% (with 14-bit resolution)
Galvanic isolation yes (operational limits at 25 °C,
Permissible potential difference referred to input range)
• between inputs (U CM) 3V Temperature error ± 0.1% (with 14-bit resolution)
• between input (M terminal) and 75 V DC (referred to input range)
central grounding point
Linearity error ± 0.015%
• Insulation tested at 500 V DC (referred to input range)
Current consumption Repeatability (under steady-state ± 0.05%
• from S7-300 backplane bus, max. 75 mA conditions, at 25 °C, referred to
• from L+, max. 150 mA input range)
Power losses, max. 3.6 W Encoder selection data
Status, interrupts, diagnostics Input range (rated values)/input
resistance
Interrupts
• Voltage ± 1 V; ± 10 V; ± 2.5 V; 0 V ... 2 V;
• Limit value interrupt no 0 V ... 10 V: 10 MΩ
• Cycle end interrupt yes, parameterizable • Current (max. 2 channels pro- ± 10 mA; 0 mA ... 20 mA;
• Diagnostics interrupt yes, parameterizable grammable as current inputs) 4 mA ... 20 mA: 100 Ω
• Unipolar 14 Bit
• Analog inputs
• For connection of voltage an d current sensors, thermocou-
ples, resistors and resistance thermometers
These modules are designed for
• an ambient range of – 25 °C to + 70 °C, condensation
permissible.
• extraordinary medial load (for example by chloric and sulphu-
ric atmospheres).
• Analog outputs
• For the connection of analog actuators
These modules are designed for
• an ambient range of – 25 °C to + 70 °C, condensation
permissible.
• extraordinary medial load (for example by chloric and sulphu-
ric atmospheres).
■ Overview
• Digital inputs for the failsafe SIMATIC S7 systems
• They are suitable for connecting:
- Switches and two-wire proximity switches (BERO)
- Sensors according to NAMUR and connected mechanical
contacts, also for signals from hazardous areas
• With integrated safety func tions for failsafe operation
• Can be used in failsafe mode
4
- Centrally: with S7-31xF-2DP
(applies only to 6ES7 326-1BK00-0AB0)
- Distributed in ET 200M: with SIMATIC S7-31xF-2DP,
S7-416F-2 and S7-400F/FH
• Suitable for use in standard operation in the same way as
S7-300 modules
■ Technical specifications
6ES7 326- 6ES7 326- 6ES7 326- 6ES7 326-
1RF00-0AB0 1BK00-0AB0 1RF00-0AB0 1BK00-0AB0
Supply voltages Digital inputs (continued)
Supply voltage of electronic and Input delay (at rated value of the
sensor components 1L+/2L+ input voltage)
- Rated value (DC) 24 V 24 V • For standard inputs
Current consumption - at 0 to 1, max. 3.4 ms
• from load voltage L+ (no load), 160 mA 450 mA - at 1 to 0, max. 3.4 ms
max. • for NAMUR inputs
• from backplane bus 5 V DC, max. 90 mA 100 mA - at 0 to 1, max 1.2 to 3 ms
• Power dissipation, typical 4.5 W 10 W
- at 1 to 0, max 1.2 to 3 ms
Connection system Sensor supply
• Requisite front connector 40-pin 40-pin 8 4; electrically
• Number of outputs
Digital inputs isolated
• Number of digital inputs 8; 24 • Output voltage 8.2 V DC
8 (single-chan- • Output current, rated value 400 mA
nel);
4 (dual-chan- Sensor
nel)
Connectable encoders
Number of inputs that can be driven - 2-wire BEROS
in parallel Yes; when
short-circuit
- Number of inputs that can be 8; vertical 24 test deacti-
driven in parallel, up to 40 °C installation vated
- Number of inputs that can be 8; horizontal 24; (at 24 V) - permissible closed-circuit 2 mA
driven in parallel, up to 60 °C installation or 18 current (2-wire BEROS), max.
(at 28.8 V) Ex(i)-modules
Length of cable • Module for Ex(i) protection Yes
- Length of cable shielded, max. 200 m 200 m Maximum values of the input
- Length of cable unshielded, max. 100 m 100 m circuits (per channel)
Input voltage - Ca (permissible external 3 µF
capacity), max.
- Rated value, DC to DIN 19234 24 V
- Io (short-circuit current), max. 13.9 mA
and NAMUR
- La (permissible external induc- 80 mH
- for signal "0" -30 to 5 V tance), max.
- for signal "1" 11 to 30 V - Po (load power), max. 33.1 mW
Input current - Uo (output open-circuit voltage), 10 V
- for 0 signal, max (permissible 0.35 to 1.2 mA 2 mA max.
closed-circuit current) - Um (fault voltage), max 60 V DC/ 30 V AC
- for 1 signal, typical 2.1 to bis 7 mA 10 mA - permissible ambient temperatu- 60 °C 60 °C
re Ta, max
■ Overview
• Digital outputs for the fa ilsafe SIMATIC S7 systems
• For connection of solenoid va lves, DC contactors and signal-
ing lamps
• With integrated safety func tions for failsafe operation
• Can be used in failsafe mode
4 - Centrally: with S7-31xF-2 DP
- Distributed in ET 200M: with SIMATIC S7-31xF-2DP,
S7-416F-2 and S7-400F/FH
• Suitable for use in standard operation in the same way as
S7-300 modules
■ Technical specifications
6ES7 326-2BF01-0AB0 6ES7 326-2BF01-0AB0
Voltages and currents Digitalausgaben (continued)
Load voltage L+ Switching frequency
- Rated value (DC) 24 V; 1L+, 2L+, 3L+ - at resistive load, max. 10 Hz
Current consumption - at inductive load, max. 2 Hz
- at lamp load, max. 10 Hz
• from load voltage 1L+, max 70 mA;
from supply voltage Summation current of the outputs
(per group)
• from load voltage 2L+ 100 mA
(no load), max. • vertical mounting positions
• from load voltage 3L+ 100 mA - up to 40°C, max. 5 A; without series diode,
(no load), max. 4 A with series diode
• from backplane bus 5 V DC, max. 100 mA • horizontal mounting positions
• Power dissipation, typical 12 W - up to 40°C, max. 7.5 A; without series diode,
5 A with series diode
Connection system
- up to 60°C, max. 5 A; without series diode,
• Requisite front connector 40-pin
4 A with series diode
Digital outputs
Status information/ interrupts/
• Number of digital outputs 10 diagnostics
• Length of cable shielded, max. 1,000 m; 200 m for SIL3, AK 5 Interrupts
and 6, Cat 4 - Diagnostic interrupt Yes
• Length of cable unshielded, max. 600 m
Diagnostics
• Short-circuit protection of the Yes; electronic - Diagnostic information Yes
output can be read out
• Limitation of voltage induced on L+ (-53 V) without series diode, Insulation
circuit interruption to L+ (-33 V) with series diode • Insulation tested with 500 V DC/ 350 V AC
• Lamp load, max. 5W Potentials/ electrical insulation
Output voltage Digital output functions
- for 1 signal with series diode L+ (-1.8 V) - between the channels Yes
- for 1 signal without series diode, L+ (-1.0 V) - between the channels, 5
min. in groups of
Output current - between the channels and the Yes
- for 1 signal rated value 2A backplane bus
- for 1 signal permissible range 7 mA - between the channels and the Yes
for 0 to 40 °C, min. electronics power supply
- for 1 signal permissible range 2 A; 2 A for horizontal installation,
for 0 to 40 °C, max. 1 A for vertical installation
- for 1 signal permissible range 7 mA
for 40 to 60 °C, min.
- for 1 signal permissible range 1 A; for horizontal installation
for 40 to 60 °C, max.
- for 0 signal residual current, max. 0.5 mA
■ Overview
• Analog inputs for the failsafe SIMATIC S7 systems
• For connection of analog sensors with voltage and current
signals
• With integrated safety func tions for failsafe operation
• Can be used in the ET 200M distributed I/O station with
4 SIMATIC S7-31xF-2 DP, S7-416F-2 and S7-400F/FH
• Suitable for use in standard operation in the same way as
S7-300 modules
■ Technical specifications
6ES7 336-1HE00-0AB0 6ES7 336-1HE00-0AB0
Voltages and currents Error/accuracies
Load voltage L+ Operational limit in the entire
- Rated value (DC) 24 V temperature range
- Reverse polarity protection Yes - relative to the input range, +/- 0.48 %
voltage
Current consumption - relative to the input range +/- 0.48 %
• from backplane bus 5 V DC, max. 90 mA current
• from supply voltage L+, max. 160 mA; typ. Basic error limit (operational
• Power dissipation, typical 4.25 W limit at 25 °C)
Connection system - relative to the input range, +/- 0.4 %
voltage
• Requisite front connector 40-pin
- relative to the input range, +/- 0.4 %
Analog inputs current
• Number of analog inputs 6 Status information/
• Number of analog inputs for 4 interrupts/ diagnostics
voltage measurement Alarme
• Length of cable shielded, max 200 m
- Diagnostic interrupt Yes; parameterizable
• Permissible input voltage for the 30 V
voltage input (destruction limit), Diagnostics
max. - Diagnostic information can be Yes
• Permissible input voltage for the 40 mA read out
current input (destruction limit), Insulation
max.
• Insulation tested with 500 V DC/ 350 V AC
Input ranges (rated values),
voltages Potentials/ electrical isolation
- 0 to +10 V Yes Analog output functions
Input ranges (rated values), - between the channels No
currents - between the channels and the Yes
- 0 to 20 mA Yes backplane bus
- 4 to 20 mA Yes - between the channels and the Yes; only when external sensor
electronics power supply power supply
Analog value formation
Standards, approvals,
Integration and conversion certification
time/triggering per channel
- with over-range (bits incl. sign), 14 Bit Maximum safety level that can be
max achieved in safety mode
- Integration time, ms 20 ms (at 50 Hz); - to comply with DIN V 19250 AK 6
16.66 ms (at 60 Hz) - to comply with EN 954 Cat. 4
- Interference voltage suppressi- 38 dB
on for interference frequency f1 - to comply with IEC 61508 SIL 3
in Hz Dimensions and weight
Sensor • Weight, approx. 480 g
Sensing element connection • Width 80 mm
- for current measurement, Yes 125 mm
as 2-wire measuring transducer • Height
- for current measurement, Yes • Depth 120 mm
as 4-wire measuring transducer
■ Overview
• I/O modules for applications within potentially explosive
chemical plants
• For connecting sensors and ac tuators from zones 1 and 2 in
hazardous area installations
• Associated electrical equipmen t [EEx ib] IIC in accordance
4 with DIN 50020
• For isolating non-intrinsically safe circuits of the programma-
ble logic controller and the intrinsically safe circuits from the
process
■ Technical specifications
6ES7 321-7RD00-0AB0 6ES7 321-7RD00-0AB0
Voltages and currents Sensor
Load voltage L+ Connectable encoders
- Rated value (DC) 24 V - NAMUR sensor Yes; Two-wire connection
Current consumption Ex(i)-modules
• from load voltage L+ (no load), 50 mA
Maximum values of the input
max.
circuits (per channel)
• from backplane bus 5 V DC, max. 80 mA
- Ca (permissible external 3 µF
• Power dissipation, typical 1.1 W capacity), max.
Connection system - Io (short-circuit current), max. 14.1 mA
• Requisite front connector 20-pin - La (permissible external induc- 100 mH
tance), max.
Digital inputs
- Po (load power), max. 33.7 mW
• Number of NAMUR inputs 4
- Uo (output open-circuit voltage), 10 V
Length of cable max.
- Length of cable unshielded, max. 200 m Status information/ interrupts/
Input voltage diagnostics
- Rated value, DC 8.2 V; from internal circuit supply Diagnostics
Input current - Diagnostic information can be Yes
- At broken wire, max. read out
0.1 mA
- At short circuit, max. 8.5 mA Potentials/ electrical isolation
■ Technical specifications
6ES7 322- 6ES7 322- 6ES7 322- 6ES7 322-
5SD00-0AB0 5RD00-0AB0 5SD00-0AB0 5RD00-0AB0
Voltages and currents Ex(i)-modules
Load voltage L+ Maximum values of the output
- Rated value (DC) 24 V 24 V circuits (per channel)
Current consumption
• from load voltage L+ (no load), 160 mA 160 mA
- Ca (permissible external
capacity), max.
- Io (short-circuit current), max.
90 nF 500 nF
4
70 mA 85 mA
max.
- La (permissible external 6.7 mH 5 mH
• from backplane bus 5 V DC, max. 70 mA 70 mA inductance), max.
• Power dissipation, typical 3W 3W - Po (load power), max. 440 mW 335 mW
Connection system - Uo (output open-circuit voltage), 25.2 V 15.75 V
max.
• Requisite front connector 20-pin 20-pin
Status information/
Digital outputs interrupts/ diagnostics
• Number of digital outputs 4 4 Diagnostics
• Length of cable unshielded, max. 200 m 200 m - Diagnostic information can be Yes Yes
• Short-circuit protection of the Yes; electronic Yes; electronic read out
output - Short circuit Yes Yes
• Short-circuit protection of the out- Output current Output current - Group error Yes Yes
put, response threshold, typical for short-circuit for short-circuit
protection, min. protection, min. Potentials/ electrical isolation
10 mA + 10 % 20.5 mA + 10 % Digital output functions
Output voltage - Electrical isolation, digital Yes Yes
- Rated value (DC) 24 V 15 V output functions
Output current - between the channels, 1 1
in groups of
- for 1 signal permissible range 10 mA; +/- 10% 20 mA; +/- 10%
for 0 to 60 °C, max. Standards, approvals,
certification
Switching frequency
• Type of protection to comply with [EEx ib] IIC [EEx ib] IIC
- at resistive load, max. 100 Hz 100 Hz EN 50020 (CENELEC)
Load impedance range • Type of protection to comply with CL I, DIV 2, AIS CL.1, DIV 1,
- upper limit FM GP A,B,C,D T4 GP A,B,C,D;
390 Ω; Two- 200 Ω; Two-
CL.I, DIV 2,
wire connection wire connection
GP A,B,C,D T4
• PTB test number Ex-96.D.2093X Ex-96.D.2102X
Dimensions and weight
• Weight, approx. 230 g 230 g
■ Overview
• I/O modules for applications within potentially explosive
chemical plants
• For connecting sensors and ac tuators from zones 1 and 2 in
hazardous area installations
• Associated electrical equipmen t [EEx ib] IIC in accordance
with DIN 50020
• For isolation of non-IS circuits of the automation system and
4
the IS circuits from the process
■ Technical specifications
6ES7 331- 6ES7 331- 6ES7 331- 6ES7 331-
7RD00-0AB0 7SF00-0AB0 7RD00-0AB0 7SF00-0AB0
Voltages and currents Analog inputs (continued)
Load voltage L+ Input ranges (rated values),
- Rated value (DC) 24 V 24 V thermocouples
- Type B Yes
Power supply of measuring
transducers - Type E Yes
- Available Yes - Type J Yes
- Rated value (DC) 13 V; at 22 mA - Type K Yes
- Open-circuit voltage (DC) 25.2 V - Type L Yes
- Type N Yes
Current consumption
- Type R Yes
• from backplane bus 5 V DC, max. 60 mA 120 mA
- Type S Yes
• from supply voltage L+, max. 150 mA
- Type T Yes
• Power dissipation, typical 3W 0.6 W
- Type U Yes
Connection system
Input ranges (rated values),
• Requisite front connector 20-pin 20-pin
resistance thermometer
Analog inputs - Ni 100 Yes
• Number of analog inputs 4 8; 8 x thermo- - Pt 100 Yes
couples, - Pt 200 Yes
4 x RTD ther-
mistors Analog value formation
• Length of cable shielded, max 200 m 200 m; • Measuring principle SIGMA-DELTA SIGMA-DELTA
HTC: 50 m
Integration and conversion
• Permissible input voltage for the 40 mA time/triggering per channel
current input (destruction limit),
max. - with over-range (bits incl. sign), 16 Bit; 16 Bit;
max. 10 to 15 bits + 10 to 15 bits +
Input ranges (rated values), sign sign
currents
- Integration time parameterizable Yes; Yes;
- 0 to 20 mA Yes
2.5 to 100 ms 2.5 to 100 ms
- 4 to 20 mA Yes
- Interference voltage suppressi- 10 to 400 Hz 10 to 400 Hz
on for interference frequency f1
in Hz
■ Overview
• Single-channel intelligent counte r module for simple counting
tasks
• For direct connection of incremental encoders
• Comparison function with 2 selectable comparison values
• Integrated digital outputs to output the response upon
reaching the comparison value.
• Operating modes:
4
- Continuous counting
- One-shot counting
- Periodic counting
• Special functions;
- Set counter
- Latch counter
• Start/stop counter with gate function
Note:
■ Technical specifications
6ES7 350-1AH03-0AE0 6ES7 350-1AH03-0AE0
Voltages and currents Digital outputs
Auxiliary voltage 1L+, • Number of digital outputs 2
load voltage 2 L+
• Short-circuit protection of the Yes; clocking electronically
- Rated value (DC) 24 V
output
• permissible range
(including ripple) • Limitation of voltage induced on 2L+ (-39 V)
- dynamic, lower limit (DC) 18.5 V circuit interruption to
- dynamic, upper limit (DC) 30.2 V Output voltage
- static, lower limit (DC) 20.4 V - for 0 signal (DC), max. 3V
- static, upper limit (DC) 28.8 V - for 1 signal 2L+ (-1.5 V)
• Non-periodic snap-over Output current
- Duration 500 ms - for 1 signal rated value 0.5 A
- Recovery time 50 s - for 1 signal permissible range 5 mA
- Value 35 V for 0 to 60 °C, min.
- für Signal 1 zulässiger Bereich 0.6 A
Current consumption für 0 bis 60 °C, max.
• from load voltage 1L+ 40 mA
(no load), max. Output delay at resistive load
• from backplane bus 5 V DC, max. 160 mA - "0" to "1", max. 300 µs
• Power dissipation, typical 4.5 W Sensor supply
Connection system 5 V - sensor supply
• Requisite front connector 1 x 20-pin - 5V Yes; 5.2 V +/-2%
Digital inputs - Output current, max. 300 mA
• Number of digital inputs 3 24 V - sensor supply
• Functions - 24 V Yes; 1L+ (-3V)
1 for gate start, 1 for gate stop,
1 for setting the counter - Output current, max. 400 mA
Input voltage Sensor
- for signal "0" -28.8 to 5 V Connectable encoders
- for signal "1" +11 to +28.8 V - Incremental encoder Yes; with 2 pulse trains
Input current (symmetrical) offset by 90°
- for 1 signal, typical 9 mA - Incremental encoder Yes
(asymmetrical)
- 24 V initiator Yes
- 24 V directional sensor Yes; 1 pulse train,
1 direction level
■ Overview
• For direct connection of 24 V incremental encoders, directio-
nal elements, initiators or NAMUR sensors
• Compare function with programmable comparison values
(number depends on operating mode).
• Integrated digital outputs to output the response upon
reaching the comparison value.
• Operating modes:
4
- Continuous/one-shot/periodic counting
- Frequency/speed control
- Period measurement
- Proportioning
Note:
SIMODRIVE Sensor/Motion Connect 500 feature incremental
encoders and preassembled connecting cables for counting
and positioning functions.
Additional information is available in the Internet under:
• 8-channel intelligent counter mo dule for universal counter and http://www.siemens.com/simatic-technology
measurement tasks
■ Technical specifications
6ES7 350-2AH00-0AE0 6ES7 350-2AH00-0AE0
Voltages and currents Digital outputs
Auxiliary voltage 1L+, load voltage • Number of digital outputs 8
2 L+ • Length of cable shielded, max. 600 m
- Rated value (DC) 24 V • Length of cable unshielded, max. 100 m
- permissible range, lower limit 20.4 V • Short-circuit protection of the Yes
(DC) output
- permissible range, upper limit 28.8 V • Limitation of voltage induced on L+ (-40 V)
(DC) circuit interruption to
Current consumption Output voltage
• from load voltage L+ (no load), 150 mA - for 1 signal L+ (-0.8 V)
max.
Output current
• from backplane bus 5 V DC, max. 100 mA
- for 1 signal rated value 0.5 A
• Power dissipation, typical 10 W
- for 0 signal residual current, max. 0.5 mA
Connection system
Output delay at resistive load
• Requisite front connector 1 x 40-pin
- "0" to "1", max. 300 µs
Digital inputs
Switching frequency
• Number of digital inputs 8
- at resistive load, max. 500 Hz
• Functions 1 each for gate start / gate stop - at inductive load, max. 0.5 Hz
Length of cable Summation current of the outputs
- Length of cable shielded, max 100 m (per group)
Input voltage - vertical installation, 2A
- for signal "0" up to 40 °C, max.
-3 to 5 V
- for signal "1" - horizontal installation, 4A
11 to 30.2 V
up to 40 °C, max.
Input current - horizontal installation, 2A
- for 0 signal, max.(permissible 2 mA up to 60 °C, max.
closed-circuit current)
Sensor supply
- for 1 signal, typical 9 mA
• Output voltage NAMUR sensor supply:
Input delay (at rated value of the 8.2 V +/-2%
input voltage)
• Output current, rated value 200 mA
• For standard inputs
• Short-circuit protection Yes
- at 0 to 1, max. 50 µs
- Count frequency, max. 20 kHz; 24 V incremental 80 mm wide, with 2 rows each for
encoder: 10 kHz, 4 terminals
24 V directional element: 20 kHz, Terminal elements
24 V initiator: 20 kHz,
NAMUR sensor: 20 kHz 2 items
- Length of cable, max. 100 m For 2 cables 6ES7 390-5AB00-0AA0
2 to 6 mm in diameter
Status information/
interrupts/ diagnostics For 1 cable 6ES7 390-5BA00-0AA0
3 to 8 mm in diameter
Interrupts
For 1 cable 6ES7 390-5CA00-0AA0
- Diagnostic interrupt Yes; parameterizable 4 to 13 mm in diameter
- Process interrupt Yes; parameterizable
Diagnostics
- Diagnostic functions Yes; Diagnostic information can
be read out
Potentials/ electrical isolation
Digital output functions
- between the channels and the Yes; and shielding
backplane bus
Digital input functions
- between the channels and the Yes; and shielding
backplane bus
- between the channels and the Yes, to backplane bus and
backplane bus (NAMUR) shielding
Electrical isolation, counters
- between the channels and the Yes; and shielding
backplane bus
Dimensions and weight
• Weight, approx. 460 g
• Width 80 mm
• Height 125 mm
• Depth 120 mm
■ Overview
• Two-channel positioning modu le for rapid-traverse/creep-
2
speed drives
• 4 digital outputs per ch annel for motor control
• Incremental or synchro-serial position decoding
Note:
SIMODRIVE Sensor/Motion Connect 500 feature position- 4
measuring systems and preassembled connecting cables for
counting and positioning functions.
■ Technical specifications
6ES7 351-1AH01-0AE0 6ES7 351-1AH01-0AE0
Supply voltages Sensor supply
Rated value 5 V - sensor supply
- 24 V DC Yes - 5V Yes
Current consumption - Output current, max. 350 mA
• Current consumption, max. 350 mA - Length of cable, max. 32 m
Connection system 24 V - sensor supply
• Requisite front connector 1 x 20-pin - 24 V Yes
- Output current, max. 400 mA; per channel
Digital inputs
8 - Length of cable, max. 100 m
• Number of digital inputs
Sensor
• Functions Reference cam, reversing cam,
set actual value on-the-fly, Connectable encoders
start/stop positioning motion - Incremental encoder Yes
Input voltage (symmetrical)
- Rated value, DC 24 V - Incremental encoder Yes
- for signal "0" (asymmetrical)
-3 to 5 V
- for signal "1" - Absolute encoder (SSI) Yes
11 to 30 V
- 2-wire BEROS Yes
Input current
- permissible closed-circuit cur- 2 mA; at signal "0", max. 2 mA;
• For 2-wire BERO rent (2-wire BEROS), max. at signal "1", max. 6 mA
- For 0 signal, typical 2 mA Incremental encoder (symmetrical)
- For 1 signal, typical 6 mA - Track mark signals A, notA, B, notB
Digital outputs - Zero mark signal N, notN
• Number of digital outputs 8 - Input signal 5 V differential signal
• Functions (phys. RS 422)
Rapid traverse, creep speed,
clockwise rotation, - Input frequency, max. 0,5 MHz
counter-clockwise rotation Incremental encoder
• Short-circuit protection of the Yes (asymmetrical)
output - Track mark signals A, B
Output voltage - Zero mark signal N
- Rated value (DC) 24 V - Input voltage 24 V
- for 1 signal UP - 0.8 V - Input frequency, max. 50 kHz; 50 kHz for 25 m cable
length, 25 kHz for 100 m cable
Output current
length
- for 1 signal permissible range 5 mA; at UPmax
for 0 to 60 °C, min. Absolute encoder (SSI)
- for 1 signal permissible range 600 mA; at UPmax - Input signal 5 V differential signal
for 0 to 60 °C, max. (phys. RS 422)
- for 0 signal residual current, max. 0.5 mA - Data signal DATA, notDATA
- Clock signal CL, notCL
- Frame length 13 or 25 Bit
- Clock frequency, max. 1 MHz
- Gray code Yes
- Length of cable (shielded), max. 300 m; at max. 125 kHz
■ Overview
• Extremely high-speed electronic cam controller
• Low-cost alternative to mechanical cam controllers
• 32 cam tracks, 13 onboard digital outputs for direct output of
actions
• Incremental or synchro-serial position decoding
Note: 4
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables for
counting and positioning functions.
Additional information is available in the Internet under:
http://www.siemens.com/simatic-technology
■ Technical specifications
6ES7 352-1AH01-0AE0 6ES7 352-1AH01-0AE0
Supply voltages Sensor supply
Rated value 5 V - sensor supply
- 24 V DC Yes - 5V Yes
Current consumption - Output current, max. 300 mA
• from load voltage L+ (no load), 200 mA - Length of cable, max. 32 m
max. 24 V - sensor supply
• from backplane bus 5 V DC, max. 100 mA - 24 V Yes
Connection system - Output current, max. 300 mA
• Requisite front connector 1 x 20-pin - Length of cable, max. 100 m
Digital inputs Sensor
• Number of digital inputs 4 Connectable encoders
• Functions Reference point switches, - Incremental encoder Yes
set actual value on-the-fly/inproc- (symmetrical)
ess length measurement, brake - Incremental encoder Yes
enabling, enable track output (asymmetrical)
No. 3
- Absolute encoder (SSI) Yes
Input voltage
- 2-wire BEROS Yes
- Rated value, DC 24 V
- permissible closed-circuit cur- 2 mA; at signal "0", max. 2 mA;
- for signal "0" -3 to 5 V rent (2-wire BEROS), max. at signal "1", max. 9 mA
- for signal "1" 11 to 30 V
Incremental encoder (symmetrical)
Input current - Track mark signals A, notA, B, notB
• For 2-wire BERO - Zero mark signal N, notN
- For 0 signal, typical 2 mA
- Input signal 5 V differential signal
- For 1 signal, typical 9 mA (phys. RS 422)
Digital outputs - Input frequency, max. 1 MHz
• Number of digital outputs 13 Incremental encoder
• Functions Cam track (asymmetrical)
• Short-circuit protection of the Yes - Track mark signals A, B
output - Zero mark signal N
Output voltage - Input voltage 24 V
- Rated value (DC) 24 V - Input frequency, max. 50 kHz; 50 kHz for 25 m cable
- for 1 signal UP - 0.8 V length, 25 kHz for 100 m cable
length
Output current
- for 1 signal permissible range Absolute encoder (SSI)
5 mA; at UPmax
or 0 to 60 °C, min. - Data signal DATA, notDATA
- for 1 signal permissible range 600 mA; at Upmax - Clock signal CL, notCL
for 0 to 60 °C, max. - Frame length 13 or 25 Bit
- for 0 signal residual current, max. 0.5 mA - Clock frequency, max. 1 MHz
- Gray code Yes
- Length of cable (shielded), max. 320 m; at max. 125 kHz
■ Overview
• The FM 352-5 High-speed Bo olean processor offers an
extremely fast binary control and some of the quickest
switching procedures ever possible (cycle duration: 1 µs)
• Programming with LAD or FBD is possible
• The instruction set availabl e includes bit instructions
(instruction subset of STEP 7), timers, counters, frequency
dividers, frequency generators, and shift registers 4
• 12 integrated DI/8 integrated DO
• 2 versions: Current sinking or current sourcing digital outputs
• 1 channel for connecting a 24 V incremental encoder,
a 5 V incremental encoder (RS422) or a serial interface
absolute encoder
A micro memory card is required for operation of the FM 352-5.
Note:
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables for
counting and positioning functions.
Additional information is available in the Internet under:
http://www.siemens.com/simatic-technology
■ Technical specifications
6ES7 352- 6ES7 352- 6ES7 352- 6ES7 352-
5AH00-0AE0 5AH10-0AE0 5AH00-0AE0 5AH10-0AE0
Supply voltages CPU/ programming
Rated value • Program cycle time (scan) 1 µs 1 µs
- 24 V DC Yes Yes Digital inputs
Voltages and currents • Number of digital inputs 8; as standard 8; as standard
and up to 12 at and up to 12 at
Load voltage L+ 24 V DC 24 V DC
- Rated value (DC) 24 V 24 V encoder inputs encoder inputs
- Reverse polarity protection Yes Yes as digital as digital
inputs inputs
- permissible range, lower limit 20.4 V 20.4 V
(DC) Length of cable
- permissible range, upper limit 28.8 V 28.8 V - Length of cable shielded, max 600 m; 600 m;
(DC) shielded cable shielded cable
Current consumption advisable when advisable when
filtering set at filtering set at
• from load voltage 1L+, max 150 mA; 150 mA; 1.6 ms raster. 1.6 ms raster.
typ. 60 mA typ. 60 mA
- Length of cable unshielded, max. 100 m 100 m
• from load voltage 2L+ 200 mA; 200 mA;
(no load), max. typ. 60 mA, typ. 60 mA, Input voltage
DE/DA supply DE/DA supply - Rated value, DC 24 V 24 V
• from load voltage 3L+ 600 mA; 600 mA; - for signal "0" -30 V to 5 V -30 V to 5 V
(with sensor), max. typ. 80 mA plus typ. 80 mA plus - for signal "1" 11 to 30 V 11 to 30 V
encoder power encoder power
supply supply Input current
• from load voltage 3L+ 200 mA; 200 mA; - for 0 signal, max (permissible 1.5 mA 1.5 mA
(no sensor), max. typ. 80 mA typ. 80 mA closed-circuit current)
• from backplane bus 5 V DC, max. 100 mA; typ. 100 mA; typ. - for 1 signal, typical 3.8 mA 3.8 mA
• Power dissipation, typical 6,5 W 6.5 W Input delay (at rated value of the
input voltage)
Memory/backup
- Input frequency 200 kHz 200 kHz
Memory (at 0.1ms delay time), max.
- Memory card, RAM 128 KByte; 128 kByte; - Programmable digital filter delay none, 5µs, none, 5µs,
required for required for 10µs, 15µs, 10µs, 15µs,
operation, operation, 20µs, 50µs, 20µs, 50µs,
MMC MMC 1,5ms 1,5ms
Interfaces - Minimum pulse width for 1µs, 5µs, 10µs, 1µs, 5µs, 10µs,
program reaction 15µs, 20µs, 15µs, 20µs,
• Update time PLC interface: PLC interface: 50µs, 1,6ms 50µs, 1,6ms
5ms 5ms
(2.6 ms typ.) (2.6 ms typ.) • For standard inputs
4 • P-switching
• Length of cable shielded, max. 600 m
Yes
600 m
- Short-circuit protection Yes; Electronic Yes; Electronic
overload pro- overload pro-
• Length of cable unshielded, max. 100 m 100 m tection. Not tection. Not
protected when protected when
• Short-circuit protection of the out- Yes; Overvolt- Yes; Overvolt- normal or normal or
put age protection, age protection, counter volt- counter volt-
thermal protec- thermal protec- age applied. age applied.
tion tion - Output current, max. 250 mA 250 mA
• Short-circuit protection of the out- 1.7 A to 3.5 A 1.7 A to 3.5 A 24 V - sensor supply
put, response threshold, typical
- 24 V Yes Yes
• Limitation of voltage induced on 2M +45 V typ, 2M +45 V typ, - Short-circuit protection
circuit interruption to (40 ..55 V) (40 ..55 V) Yes; Overcur- Yes; Overcur-
Note: no pro- Note: no pro- rent and over- rent and over-
tection against tection against heating heating
inductive kick- inductive kick- protection pn protection pn
back >55mJ back >55mJ overload. Diag- overload. Diag-
nostics, if out- nostics, if out-
• Lamp load, max. 5W 5W put put
• Driving a digital input No No temperature temperature
limit reached. limit reached.
Output voltage Not protected Not protected
- Rated value (DC) 24 V 24 V when normal or when normal or
- for 0 signal (DC), max. 28.8 V 28.8 V counter volt- counter volt-
- for 1 signal (DC), max. age applied age applied
0.5 V 0.5 V
- Output current, max. 400 mA 400 mA
Output current
- for 1 signal rated value Sensor
0.5 A; at 60 °C 0.5 A; at 60 °C
- for 1 signal permissible range 5 mA 5 mA Connectable encoders
for 0 to 60 °C, min. - Incremental encoder Yes Yes
- for 1 signal permissible range 600 mA 600 mA (symmetrical)
for 0 to 60 °C, max. - Incremental encoder Yes Yes
- for 0 signal residual current, max. 1 mA 1 mA (asymmetrical)
- Absolute encoder (SSI) Yes Yes
Output delay at resistive load
- permissible closed-circuit cur- Yes; typ. 1 A Yes; typ. 1 A
- "0" to "1", max. 1 µs; 1 µs; rent (2-wire BEROS), max.
0.6 µs 50 mA / 0.6 µs 50 mA /
1.0 µs 0.5 Amp 1.0 µs 0.5 Amp Incremental encoder (symmetrical) 1.5 mA 1.5 mA
- "1" to "0", max. 1.5 µs; 1.5 µs; - Track mark signals
1.7µs 50 mA / 1.7µs 50 mA / - Zero mark signal A, notA, B, notB A, notA, B, notB
1.5µs 0.5 Amp 1.5µs 0.5 Amp
- Input signal N, notN N, notN
Parallel switching of 2 outputs
- Input frequency, max. 5 V-Differenz- 5 V-Differenz-
- to increase power Yes; 2 Yes; 2 signal signal
Switching frequency (phys. RS 422) (phys. RS 422)
- Length of cable (shielded), max. 1 MHz 1 MHz
- at resistive load, max. 100 kHz; 100 kHz;
20 kHz at 0.5 20 kHz at 0.5 - permissible closed-circuit 100 m; Cable 100 m; Cable
amps; amps; current (2-wire BEROS), max. length, RS-422 length, RS-422
100 kHz at 0.25 100 kHz at 0.25 (5V) incremen- (5V) incremen-
amp amp tal encoder, tal encoder,
Siemens Type Siemens Type
- at inductive load, max. 2 Hz; 2 Hz at 2 Hz; 2 Hz at 6FX201-2, 5V 6FX201-2, 5V
0.5 amps with 0.5 amps with supply: supply:
external com- external com- 500kHz, 32 500kHz, 32
mutator diodes; mutator diodes; meters, meters,
0.5Hz at 0.5 0.5Hz at 0.5 shielded, max.; shielded, max.;
amps without amps without cable length, cable length,
external com- external com- RS-422 (5V) RS-422 (5V)
mutator diodes mutator diodes incremental incremental
- at lamp load, max. 10 Hz 10 Hz encoder, Sie- encoder, Sie-
mens Type mens Type
6FX201-2, 24V 6FX201-2, 24V
supply: 500 supply: 500
kHz, 100 kHz, 100
meters, meters,
shielded, max. shielded, max.
■ Overview
• Positioning module for stepper motors in machines with high
clock pulse rates
• Can be used for point-to-poi nt positioning tasks and for
complex traversing patterns
■ Technical specifications
6ES7 353-1AH01-0AE0 6ES7 353-1AH01-0AE0
Supply voltages Drive interface
Rated value Signal input I
- 24 V DC Yes - Function "Power section ready"
- permissible range, 20.4 V
Signal output I
lower limit (DC)
- permissible range, 28.8 V - Type 5 V differential signal
upper limit (DC) (phys. RS 422)
Current consumption - Function Direction, enable, clock, current
control
• Current consumption, max. 300 mA
- Differential output voltage, min. 2 V; RL = 100 Ohm
Connection system
• Requisite front connector 1 x 20-pin - Differential output voltage, 1 V; Io = 20 mA
for 0 signal, max.
Digital inputs
- Differential output voltage, 3.7 V; Io = -20 mA
• Number of digital inputs 4; for I signal, min.
(+ 1 input for the message signal) - Length of cable, max. 35 m
• Functions Reference cam, set actual value Potentials/ electrical isolation
on-the-fly, inprocess measure-
ment, start/stop positioning Digital output functions
motion, external block change - Electrical isolation, No
Input voltage digital output functions
- Rated value, DC 24 V Digital input functions
- for signal "0" -3 to 5 V - Electrical isolation, No
- for signal "1" 11 to 30 V digital input functions
■ Overview
• Positioning module for servo mo tors in machines with high
clock pulse rates
• Can be used for point-to-poi nt positioning tasks and for
complex traversing patterns
Note:
SIMODRIVE Sensor/Motion Connect 500 feature position-
4
measuring systems and preassembled connecting cables for
counting and positioning functions.
Additional information is available in the Internet under:
http://www.siemens.com/simatic-technology
■ Technical specifications
6ES7 354-1AH01-0AE0 6ES7 354-1AH01-0AE0
Supply voltages Sensor supply
Rated value 5 V - sensor supply
- 24 V DC Yes - 5V Yes
Current consumption - Output current, max. 220 mA
• Current consumption, max. 350 mA - Length of cable, max. 35 m
Connection system 24 V - sensor supply
• Requisite front connector 1 x 20-pin - 24 V Yes
- Output current, max. 300 mA
Digital inputs
- Length of cable, max. 100 m
• Number of digital inputs 4
Sensor
• Functions Reference cam, set actual value
on-the-fly, inprocess measure- Connectable encoders
ment, start/stop positioning - Incremental encoder Yes
motion, external block change (symmetrical)
Input voltage - Absolute encoder (SSI) Yes
- Rated value, DC 24 V Incremental encoder (symmetrical)
- for signal "0" -3 to 5 V - Track mark signals A, notA, B, notB
- for signal "1" 11 to 30 V - Zero mark signal N, notN
Input current - Input signal 5 V differential signal
- for 0 signal, max (permissible 2 mA (phys. RS 422)
closed-circuit current)
- Input frequency, max. 1 MHz
- for 1 signal, typical 6 mA; 6 to 15 mA
Absolute encoder (SSI)
Digital outputs
• Number of digital inputs 4 - Input signal 5 V differential signal
(phys. RS 422)
• Functions Position reached: stop, axis trav-
els forward, axis travels back, - Data signal DATA, notDATA
change M function M97, change - Clock signal CL, notCL
M function M98, start enable,
direct output via data record - Frame length 13, 21 or 25 bits
• Short-circuit protection of the Yes - Clock frequency, max. 1.25 Mbit/s
output
- Length of cable (shielded), max. 100 m; 10 m at 1.25 Mbit/s,
Output voltage 100 m at max. 125 kBit/s
- Rated value (DC) 24 V
- for 1 signal UP - 3 V
Output current
- for 1 signal permissible range 0.6 A; at UPmax
for 0 to 55 °C, max.
- for 0 signal residual current, max. 2 mA
■
6ES7 354-1AH01-0AE0 6ES7 354-1AH01-0AE0
Drive interface Potentials/ electrical isolation
Signal input I Digital output functions
- Type Controller message input, - Electrical isolation, No
isolated (optical coupler) digital output functions
■ Overview
• Path and positioning control for in telligent motion control of up
to 4 axes
• Covers a wide spectrum from independent individual positio-
ning axes through to interpolatory multi-axis continuous-path
control
• For the control of stepper mo tors and controlled servo-drive
axes 4
• User-friendly startup through easy-to-use parameterization
tool
• Interface for SIMODRIVE 611U and MASTERDRIVES MC via
the isochronous PROFIBUS (not for FM 357-2H in combination
with HT6)
Note:
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables for
counting and positioning functions.
Additional information is available in the Internet under:
http://www.siemens.com/simatic-technology
■ Technical specifications
6ES7 357-4AH01-0AE0 6ES7 357-4AH01-0AE0
Supply voltages Sensor supply
Rated value 5 V - sensor supply
- 24 V DC Yes - 5V Yes
Voltages and currents - Output current, max. 210 mA
• Power consumption, typical 24 W - Length of cable, max. 35 m
Current consumption 24 V - sensor supply
• from backplane bus 5 V DC, max. 100 mA - 24 V Yes
- Output current, max. 300 mA
Memory/backup
- Length of cable, max. 100 m
Memory
- NC-program memory Sensor
750 KByte
Connectable encoders
Connection system
- Incremental encoder Yes
• Requisite front connector 1 x 40-pin
(symmetrical)
Digital inputs - Absolute encoder (SSI) Yes
• Number of digital inputs 18
Incremental encoder (symmetrical)
• Functions 4 Bero, 2 touch probes, - Track mark signals A, notA, B, notB
12 used as you choose
- Zero mark signal N, notN
Input voltage - Input signal 5 V differential signal
- Rated value, DC 24 V (phys. RS 422)
- for signal "0" -3 to 5 V - Input frequency, max. 1 MHz
- for signal "1" 11 to 30 V
Absolute encoder (SSI)
Input current - Input signal 5 V differential signal
- for 0 signal, max (permissible 2 mA (phys. RS 422)
closed-circuit current)
- for 1 signal, typical - Data signal DATA, notDATA
6 mA; 6 to 30 mA
- Clock signal CL, notCL
Digital outputs
- Frame length 13, 21 or 25 Bit
• Number of digital outputs 8
- Clock frequency, max. 1.5 Mbit/s
• Functions 8 freely usable
- Length of cable (shielded), max. 250 m; at max. 187.5 kBit/s
Output voltage
Positioning
- Rated value (DC) 24 V
• Programmable traversing speed, 1,000 m/min
- for 1 signal UP - 3 V
max.
Output current
- for 1 signal permissible range 0.5 A; at UPmax
for 0 to 55 °C, max.
- for 0 signal residual current, max. 2 mA
The FM STEPDRIVE can be used for stepper motors with Permissible ambient temperature
torques in the 2 Nm (17.702 lb-in) to 15 Nm (132.762 lb-in) • Storage and transport -40 … +70 °C (-40 … +158 °F)
range.
• Operation 0 … +60 °C (32 … 140 °F) with
derating and dependent on
mounting position
Weight, approx. 0.85 kg (1.87 lb)
Dimensions (W x H x D) 80 mm x 125 mm x 118 mm
(3.15 in x 4.92 in x 4.65 in)
1) Enable signal (enabling of power section), optionally either 5 V via pulse
interface or 24 V via signal interface.
Holding Brake
Motor type 1FL304. 1FL306.
Rated voltage 24 V
Minimum holding voltage 10 V (at the earliest 130 ms after
for released brake excitation)
Electrical pickup power 24 W 32 W
Switching times
• Release brake 35 ms 65 ms
• Close brake 15 ms 15 ms
Type of connection Connector (mating connector
in scope of supply)
For length code as well as power and signal cables, see "MOTION-CONNECT cables and connections".
■ Overview
• 4-channel closed-loop control module for universal closed-
loop control tasks
• Used for temperature, pressure, flowrate and fill-level control
loops
• User-friendly online self-optim ization for temperature controls
4 • Preprogrammed controller structures
• 2 control algorithms
• 2 versions:
- FM 355 C as continuous-action controller;
- FM 355 S as step or pulse controller
• With 4 analog outputs (FM 355 C) or 8 digital outputs (FM 355 S)
for direct control of the most common types of actuator
• Continued operation of the contro l loop is possible even after
a CPU stop or failure
■ Technical specifications
6ES7 355- 6ES7 355- 6ES7 355- 6ES7 355-
0VH10-0AE0 1VH10-0AE0 0VH10-0AE0 1VH10-0AE0
Voltages and currents Digital outputs
Load voltage L+ • Number of digital outputs 8
- Rated value (DC) 24 V 24 V • Length of cable shielded, max. 1,000 m
- permissible range, 20.4 V 20.4 V • Length of cable unshielded, max. 600 m
lower limit (DC) • Short-circuit protection of the Yes;
- permissible range, 28.8 V 28.8 V output electronic
upper limit (DC) • Limitation of voltage induced on L+ (-1.5 V)
Current consumption circuit interruption to
• from load voltage L+ (no load), 310 mA; 270 mA; • Lamp load, max. 5W
max. typ. 260 mA typ. 220 mA • Driving a digital input Yes
• from backplane bus 5 V DC, max. 75 mA; 75 mA; Output voltage
typ. 50 mA typ. 50 mA
- for 1 signal L+ (-2.5 V)
• Power dissipation, max. 7.8 W 6.9 W
• Power dissipation, typical 6.5 W 5.5 W Output current
- for 1 signal rated value 100 mA
Connection system
- for 1 signal permissible range 5 mA
• Requisite front connector 2 x 20-pin 2 x 20-pin for 0 to 60 °C, min.
Digital inputs - for 1 signal permissible range 150 mA
for 0 to 60 °C, max.
• Number of digital inputs 8 8
- for 0 signal residual current, max. 0.5 mA
Length of cable
Parallel switching of 2 outputs
- Length of cable shielded, max. 1,000 m 1,000 m
- for logical links Yes
- Length of cable unshielded, 600 m 600 m
max. Switching frequency
• Input characteristic to comply with Yes Yes - at resistive load, max. 100 Hz
IEC 1131, Type 2 - at inductive load, max. 0.5 Hz
Input voltage - at lamp load, max. 100 Hz
- Rated value, DC 24 V 24 V Summation current of the outputs
- for signal "0" -3 to 5 V -3 to 5 V (per group)
- for signal "1" 13 to 30 V 13 to 30 V - up to 60 °C, max. 400 mA
Input current Load impedance range
- for 1 signal, typical 7 mA 7 mA - lower limit 240 Ω
- upper limit 4 kΩ
■ Overview
• 4-channel closed-loop control module specially for tempera-
ture controls
• With convenient, integrated online self-optimization
• Heating and cooling controls as well as combined controls
with a heating and active cooling function can be imple-
mented
• Preprogrammed controller structures
4
• 2 variants:
- FM 355-2 C as a continuous-action controller;
- FM 355-2 S as a step-action or pulse controller
• With 4 analog outputs (FM 355-2 C) or 8 digital outputs
(FM 355-2 S) for direct control of the most commonly used final
control elements
• The controller will continue to operate in the event of a CPU
Stop or CPU failure
■ Technical specifications
6ES7 355- 6ES7 355- 6ES7 355- 6ES7 355-
2CH00-0AE0 2SH00-0AE0 2CH00-0AE0 2SH00-0AE0
Voltages and currents Digital outputs
Load voltage L+ • Number of digital outputs 8
- Rated value (DC) 24 V 24 V • Length of cable shielded, max. 1,000 m
- permissible range, 20.4 V 20.4 V 600 m
• Length of cable unshielded, max.
lower limit (DC)
- permissible range, 28.8 V 28.8 V • Short-circuit protection of the Yes;
upper limit (DC) output electronic
• Limitation of voltage induced on L+ (-1.5 V)
Current consumption
circuit interruption to
• from load voltage L+ (no load), 310 mA; 270 mA;
max. typ. 260 mA typ. 220 mA • Lamp load, max. 5W
• from backplane bus 5 V DC, max. 75 mA; 75 mA; • Driving a digital input Yes
typ. 50 mA typ. 50 mA
Output voltage
• Power dissipation, max. 7.8 W 6.9 W
- for 1 signal L+ (-2.5 V)
• Power dissipation, typical 6.5 W 5.5 W
Output current
Connection system
- for 1 signal rated value 0.1 A
• Requisite front connector 2 x 20-pin 2 x 20-pin
- for 1 signal permissible range 5 mA
Digital inputs for 0 to 60 °C, min.
8 8 - for 1 signal permissible range 150 mA
• Number of digital inputs
for 0 to 60 °C, max.
Length of cable - for 0 signal residual current, max. 0.5 mA
- Length of cable shielded, max. 1,000 m 1,000 m
Parallel switching of 2 outputs
- Length of cable unshielded, 600 m 600 m - for logical links Yes
max.
• Input characteristic to comply with Yes Yes Switching frequency
IEC 1131, Type 2 - at resistive load, max. 100 Hz
Input voltage - at inductive load, max. 0.5 Hz
- Rated value, DC 24 V 24 V - at lamp load, max. 100 Hz
- for signal "0" -3 to 5 V -3 to 5 V Summation current of the outputs
- for signal "1" 13 to 30 V 13 to 30 V (per group)
- up to 60 °C, max. 400 mA
Input current
- for 1 signal, typical 7 mA 7 mA Load impedance range
- lower limit 240 Ω
- upper limit 4 kΩ
• Permissible input voltage for the 20 V 20 V - for voltage output 2-wire Yes
voltage input (destruction limit), connection
max.
- for current output 2-wire Yes
• Permissible input voltage for the 40 mA 40 mA connection
current input (destruction limit),
max. Burden resistance
(in the nominal output range)
Input ranges (rated values),
- at voltage outputs, min. 1 kΩ
voltages
- at voltage outputs, capacitive 1 µF
- 0 to +10 V Yes Yes load, max.
- -1.75 to +11.75 V Yes Yes - at current outputs, max. 500 Ω
Input ranges (rated values), - at current outputs, inductive 1 mH
currents load, max.
- 0 to 20 mA Yes Yes Analog value formation
- 0 to 23.5 mA Yes Yes
• Measuring principle integrating integrating
- -3.5 to +23.5 mA Yes Yes
Integration and conversion
- 4 to 20 mA Yes Yes time/triggering per channel
Input ranges (rated values), - with over-range (bits incl. sign), 14 Bit 14 Bit
thermocouples max
- Type B Yes Yes - Conversion time (per channel) 100 ms; at 50 100 ms; at 50
- Type E Yes Yes and 60 Hz and 60 Hz
- Type J Yes Yes Settling time
- Type K Yes Yes - for resistive load 0.1 ms 0.1 ms
- Type R Yes Yes - for capacitive load 3.3 ms 3.3 ms
- Type S Yes Yes - for inductive load 0.5 ms 0.5 ms
Input ranges (rated values), Sensor
resistance thermometer
- Pt 100 Yes Yes Sensing element connection
- for voltage measurement Yes Yes
Characteristic curve linearization
- for current measurement, as Yes Yes
- parameterizable Yes Yes 4-wire measuring transducer
- for thermocouples Type B, E, J, K, Type B, E, J, K, Connectable encoders
R, S R, S
- 2-wire BEROS Yes Yes
- for resistance thermometer Pt 100 Pt 100
(standard) (standard) - permissible closed-circuit cur- 1.5 mA 1.5 mA
rent (2-wire BEROS), max.
Temperature compensation
Error/accuracies
- external temperature compen- Yes Yes
sation with Pt100 • Linearity error +/- 0.05 %
(relative to the output range)
- internal temperature compen- Yes Yes
sation possible • Linearity error +/- 0.05 % +/- 0.05 %
(relative to the input range)
Analog outputs • Temperature error +/- 0.02 %/K
• Number of analog outputs 4 (relative to the output range)
• Length of cable shielded, max. 200 m; • Temperature error +/- 0.005 %/K +/- 0.005 %/K
50m at 80 mV (relative to the input range)
and thermo-
couples Operational limit in the entire
temperature range
• Voltage output, Yes
- Relative to the output range, +/- 0.5 %
short-circuit protection voltage
• Voltage output, 25 mA - Relative to the output range, +/- 0.6 %
short-circuit current, max current
• Current output, 18 V - relative to the input range, +/- 0.6 %; +/- 0.06 %;
open-circuit voltage, max. voltage +/-0.6 to +/-0.06 to
+/-0.7% +/-0.7%
Output ranges, voltage - relative to the input range, +/- 0.6 %; +/- 0.06 %;
- 0 to 10 V Yes current +/-0.6 to +/-0.06 to
+/-0.7% +/-0.7%
- -10 to +10 V Yes - relative to the input range, +/- 0.6 %; +/- 0.06 %;
resistance thermometer +/-0.6 to +/-0.06 to
+/-0.7% +/-0.7%
■ Overview
• Interface between a maximum of 3 absolute position encoders
(SSI) and the CPU.
• To provide the position-encoder values for subsequent pro-
cessing in the STEP 7 program.
• Enables the programmable controller’s direct response to
4 encoder values in moving systems.
Note:
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables
for counting and positioning functions.
Additional information is available in the Internet under:
http://www.siemens.com/simatic-technology
■ Technical specifications
6ES7 338-4BC01-0AB0 6ES7 338-4BC01-0AB0
Voltages and currents Sensor supply
Load voltage L+ 24 V - sensor supply
- Rated value (DC) 24 V - 24 V Yes; L+ (-0,8 V)
- permissible range, 20.4 V - Output current, max. 900 mA
lower limit (DC)
Sensor
- permissible range, 28.8 V
upper limit (DC) • Number of sensors that can be 3
connected, max.
Current consumption
Connectable encoders
• from load voltage L+ (no load), 10 mA - Absolute encoder (SSI)
max. Yes
- 2-wire BEROS Yes
• from backplane bus 5 V DC, max. 160 mA
• Power dissipation, typical 3W Absolute encoder (SSI)
Connection system - Length of cable (shielded), max. 320 m; 320 m at 125 kHz,
160 m at 250 kHz, 60 m at
• Requisite front connector 20-PIN
500 kHz, 20 m at 1 MHz
Digital inputs
Status information/
Length of cable interrupts/ diagnostics
- Length of cable shielded, max. 600 m Interrupts
Input voltage - Diagnostic interrupt Yes
- for signal "0" -3 to 5 V Potentials/ electrical isolation
- for signal "1" 11 to 30,2 V • Description No
Input current Dimensions and weight
- for 0 signal, max (permissible 2 mA
closed-circuit current) • Weight, approx. 235 g
- for 1 signal, typical 9 mA • Width 40 mm
• Height 125 mm
Input delay (at rated value of the
input voltage) • Depth 120 mm
■ Overview
SIWAREX U is the optimum solution wherever strain gauge
sensors, such as load cells, force sensors or torque measuring
shafts, are used for measuring tasks. The following are typical
SIWAREX U applications:
• Fill level monitoring of silos and bunkers
■ Technical specifications
Integration in automation systems: Load cell powering
• S5-95U/DP (PROFIBUS master) Via ET 200M • Supply voltage Us (rated value) 10.3 V DC
• S5-115U/-135U/-155U Via ET 200M • Max. supply current ≤ 240 mA single-channel
• S7-300 Direct integration ≤ 120 mA two-channel
• S7-400 Via ET 200M • Permissible load resistance
• PCS 7 Via ET 200M (per weighing channel)
• M7-300 Direct integration -RLmin > 41 Ω single-channel
> 82 Ω two-channel
• M7-400 Via ET 200M
• C7 Via IM or ET 200M -RLmax <4010 Ω
• Automation systems from other Via ET 200M With Ex(i) interface:
vendors -RLmin > 87 Ω
Stand-alone Possible with IM 153-1 -RLmax <4010 Ω
(without SIMATIC CPU)
Permissible load cell Up to 4mV/V
Communication interfaces • SIMATIC S7 (P bus) characteristic
• RS 232
Permissible range of measuring -1.5 to +42.5 mV
• TTY signal (at greatest set character-
Connection of remote indicators Gross, channel 1, 2 or default istic)
(through TTY serial interface) value 1, 2 Max. distance of load cells 1000 m (300 m in Ex area (up to
Adjustment of scales settings Using SIMATIC S5/S7/M7/C7 1000 m, depending on the gas
(P bus) or SIWATOOL U parame- group))
terization software (RS232) Intrinsically-safe Optional (Ex interface)
Measuring properties load cell powering
• Error limit according to DIN 1319-1 0.05 % Supply voltage 24 V DC
of full-scale value at 20 °C ±10K
• Rated voltage 24 V DC
• nIND according to EN 45501 3,000 (not legal-for-trade) 220 mA
Minimum measuring signal ∆Umin 1.5 µV • Max. current consumption
per d Voltage supply from backplane typ. 100 mA
• Internal resolution 65,535 bus
Data format of weight values 2 byte (fixed-point) Certification UL, CSA, FM
Number of 50 IP degree of protection to IP20
measurements/second DIN EN 60529; IEC 60529
Digital filter 0.05 - 5 Hz (in 7 steps), Climatic requirements
mean-value filter Tmin (IND) to Tmax (IND))
Weighing functions (operating temperature)
• Weight values Gross • Vertical installation 0 ... +60 °C
• Limits 2 (min./max.) • Horizontal installation 0 ... +40 °C
• Zero setting function Per command EMC requirements according to NAMUR NE21, Part 1
Load cells Strain gauges in 89/386/EEC
4-wire or 6-wire system
SIWAREX M
■ Overview
SIWAREX M is the optimum solution wherever weighing or pro-
portioning have to be carried out at high accuracy. The following
are typical SIWAREX M applications:
• Non-automatic weighing machines
• Exact fill level monitoring of silos and bunkers
• Single-component proportioning weigher
• Multi-component scales (wit h the SIWAREX Batch software)
• Weighing in potentially explosive areas
(zone 1 using SIWAREX IS Ex interface)
■ Technical specifications
SIWAREX M Stand-alone (without SIMATIC) Yes
Main applications • Platform scales Integration in:
• Fill level (containers/bins) • S5-90/-95U/-100U Via RS232/TTY+CP
• S5-95U/DP (PROFIBUS master) Via RS232/TTY+CP
• Proportioning and batching
scales • S5-115U/-135U/-155U Via ET 200M
• S7-300 Direct integration
• Scales with verification
capability • S7-400 Via ET 200M
• PCS 7 Via ET 200M
Intrinsically-safe Optional (Ex-l) • C7 Via IM or ET 200M
load cell powering
• TELEPERMM (AS388/488/TM) Via ET 200M
■ Overview
• Intelligent 8-channel electron ics module for S7-300/ET 200M
• For the connection of up to 8 IQ-Sense sensors:
- Optoelectronic sensors
- Ultrasound sensors
• With standard function blocks for the various sensor technolo-
4 gies for simplified handling on a SIMATIC S7
• Conventional sensors cannot be operated.
■ Overview
Opto BERO with IQ Sense, C 40 form Opto BERO with IQ Sense, K 80 form
The photoelectric proximity switches react to changes in the re- Depending on the type of BERO, the interruption or reflection of
ceived quantity of light. The light beam emitted from the emitter the light beam is evaluated. The following operating modes are
diode is interrupted or reflected by the object to be detected. possible with IQ Sense:
These sensors detect all objects regardless of their composition, • Diffuse sensors (energetic)
whether metal, wood or plastic. • Diffuse sensors with background suppression
• Retroreflective sensors.
Features:
• C 40 IQ Sense and K 80 IQ Sense forms
• IntelliTeach functionality
• Integral anti-interference function
• Advanced failure signal (c ontamination/maladjustment)
■ Technical specifications
Form C40 IQ Sense K80 IQ Sense
Diffuse sensor (energetic sensor)
Sensing range m 0.7 2
Standard target mm 200 × 200 (white)
Emitter (type of light) nm 660 (red LED ) 880 (IR LED)
Current input mA 50
Response time ms 1
LEDs Switching display (yellow), surplus light (green)
Enclosure material ABS + PBTP PBTP
Degree of protection IP67
Dimensions mm 40 × 40 × 53 83 × 65 × 25
Diffuse sensor with background suppression
Sensing range m – 0.2 ... 1
Standard target mm – 200 × 200 (white)
Emitter (type of light) nm – 880 (IR LED)
Current input mA – 50
Response time ms – 2
LEDs – Switching display (yellow), surplus light (green)
Enclosure material – PBTP
Degree of protection – IP67
Dimensions mm – 83 × 65 × 25
4 Response time
LEDs
ms 1
Switching display (yellow), surplus light (green)
Enclosure material ABS + PBTP PBTP
Degree of protection IP67
Dimensions mm 40 × 40 × 53 83 × 65 × 25
■ Overview
The Sonar BEROs of the M18 IQ compact range are all-in-one
units ready for connection, and have a cylindrical M 18 enclo-
sure for connection to the S7-300/ET 200M IQ Sense module
SM338, 8×IQ Sense
• 5 operating modes
- Operation as a measuring sensor ("Analog signal"),
- Diffuse sensor with background suppression,
- Diffuse sensor with large differential travel,
4
- Diffuse sensor with foreground and background suppres-
sion,
- Retroreflective sensor.
• Static setting of parameters using STEP 7
• Dynamic setting of parameters using an S7 function block
• Measured distance from object is always transmitted
• Synchronization capabilit y, multiplex operation
• Temperature compensation
• Connection through M12 connector
• Non-polarized two-wire system (protected against polarity
reversal)
• Channel-specific system diagnostics (e.g. wire break, short-
circuit, parameterization faults).
■ Technical specifications
Type 3SF62 32–3JA00 3SF62 33–3JA00
Sensing range
• Rated value cm 5 ... 30 15 ... 100
• Maximum value cm 5 ... 50 15 ... 150
Standard target mm 10 × 10 20 × 20
Differential travel H (adjustable) mm 3 ... 30 10 ... 100
Repeat accuracy R mm 1 2
Operational voltage (DC) From IQ Sense
Rated operating current Ie From IQ Sense
No-load supply current I0 From IQ Sense
Adjustment/parameterization Start and end of the switching range using IQ Sense (IntelliTeach) or local teach-in using potentiometer
Ultrasonic frequency kHz 400 200
Switching frequency f Hz 8 4
Response time ms 54 110
Measuring time ms 13.44 26.88
Status display Yellow LED
Enclosure material Brass, nickel-plated,
CRASTIN converter cover;
epoxy resin converter surface
Degree of protection IP67
Ambient temperature
• Operation °C –25 ... +70
• Storage °C –40 ... +85
• Simulator module for testing programs during startup and • Height 125 mm
operation • Depth 120 mm
• For simulation of sens or signals using switches
• For indicating signal status es at the output using LEDs ■ Ordering data
Ordering data Order No.
SM 374 simulator module A) 6ES7 374-2XH01-0AA0
Including bus connector and
labeling strip
Bus connector 6ES7 390-0AA00-0AA0
1 unit (spare part)
Labeling strip 6ES7 392-2XX00-0AA0
10 units (spare part)
S7-SmartLabel 2XV9 450-1SL01-0YX0
Software for machine labeling of
modules directly from the STEP 7
project
Labeling sheets for machine
labeling
for 16-channel signal modules,
DIN A4, for printing using laser
printer; 10 units
• Petrol 6ES7 392-2AX00-0AA0
• Light beige 6ES7 392-2BX00-0AA0
• Yellow 6ES7 392-2CX00-0AA0
• Red 6ES7 392-2DX00-0AA0
Label cover 6ES7 392-2XY00-0AA0
10 units (spare part)
A) Subject to export regulations: AL: N and ECCN: EAR99H
■ Overview
• The economical complete soluti on for serial communication
via point-to-point links.
• 3 versions with different transmission interfaces:
- RS 232C (V.24)
- 20 mA (TTY)
- RS 422/RS 485 (X.27)
4 • Implemented protocols:
- ASCII
- 3964 (R) (not for RS 485)
- Printer driver
• Simple parameterization via a parameterization tool integrated
into STEP 7
■ Technical specifications
6ES7 340-1AH01-0AE0 6ES7 340-1BH00-0AE0 6ES7 340-1CH00-0AE0
Current consumption
• from backplane bus 5 V DC, max. 165 mA 220 mA 165 mA
• Power dissipation, max. 0.85 W 0.85 W 0.85 W
Interfaces
• Number 1; electrically isolated 1; electrically isolated 1; electrically isolated
• Physical interface, 20mA (TTY) Yes
• Physical interface, RS 232C (V.24) Yes
• Physical interface, RS422/RS485 Yes
(X.27)
• Transmission rate, max. 19.2 kBit/s 9.6 kBit/s 19.2 kBit/s
• Transmission rate, min. 2.4 kBit/s 2.4 kBit/s 2.4 kBit/s
Point-to-point
• Length of cable, max. 15 m 1,000 m; 1,200 m
(100 m active, 1000 m passive)
• Supported printers HP-Deskjet, HP-Laserjet, HP-Deskjet, HP-Laserjet, HP-Deskjet, HP-Laserjet
IBM-Proprinter, user-defined IBM-Proprinter, user-defined IBM-Proprinter, user-defined
Frame length, max.
- 3964 (R) 1,024 Byte 1,024 Byte 1,024 Byte
- ASCII 1,024 Byte 1,024 Byte 1,024 Byte
Transmission rate,
20 mA (TTY)
- with 3964 (R) protocol, max. 19.2 kBit/s
- with ASCII protocol, max. 9.6 kBit/s
- with printer driver, max. 9.6 kBit/s
Transmission rate,
RS 422/485
- with 3964 (R) protocol, max. 19.2 kBit/s
- with ASCII protocol, max. 9.6 kBit/s
- with printer driver, max. 9.6 kBit/s
Transmission rate,
RS232
- with 3964 (R) protocol, max. 19.2 kBit/s
- with ASCII protocol, max. 9.6 kBit/s
- with printer driver, max. 9.6 kBit/s
■ Overview
• For powerful, high-speed serial communication via point-to-
point links
• 3 versions with differ ent physical properties:
- RS 232C (V.24)
- 20 mA (TTY),
- RS 422/RS 485 (X.27)
• Implemented protocols: ASCII, 3964 (R), RK 512, customer- 4
specific protocols (reloadable)
• Simple parameterization via a parameterization tool integrated
into STEP 7
■ Technical specifications
6ES7 341-1AH01-0AE0 6ES7 341-1BH01-0AE0 6ES7 341-1CH01-0AE0
Supply voltages
Rated value
- 24 V DC Yes Yes Yes
Current consumption
• from backplane bus 5 V DC, max. 70 mA 70 mA 70 mA
• from supply voltage L+, max. 200 mA 200 mA 240 mA
• Power dissipation, max. 4.8 W 4.8 W 5.8 W
Interfaces
• Number 1; electrically isolated 1; electrically isolated 1; electrically isolated
• Physical interface, 20mA (TTY) Yes
• Physical interface, RS 232C (V.24) Yes
• Physical interface, RS422/RS485 Yes
(X.27)
• Transmission rate, max. 76.8 kBit/s 19.2 kBit/s 76.8 kBit/s
• Transmission rate, min. 0.3 kBit/s 0.3 kBit/s 0.3 kBit/s
Connection system
• PtP 9-pin sub-D male connector 9-pin sub-D male connector 15-pin sub-D male connector
• Power supply 3 screw terminals: L+, M, GND 3 screw terminals: L+, M, GND 3 screw terminals: L+, M, GND
Point-to-point
• Length of cable, max. 15 m 1,000 m 1,200 m
Integral protocol driver
- 3964 (R) Yes Yes Yes; not with RS 485
- ASCII Yes Yes Yes
- Customer-specific drivers Yes Yes Yes
for later loading
- RK512 Yes Yes Yes; not with RS 485
Frame length, max.
- 3964 (R) 1,024 Byte 1,024 Byte 1,024 Byte
- ASCII 1,024 Byte 1,024 Byte 1,024 Byte
- RK512 1,024 Byte 1,024 Byte 1,024 Byte
■ Overview
• PROFIBUS DP master or slave wi th electrical interface for
connecting the SIMATIC S7-300 and the SIMATIC C7 to
PROFIBUS at up to 12 Mbit/s (including 45.45 kbit/s)
• Communication services:
- PROFIBUS DP-V0
- PG/OP communication
4 - S7 communication (client, server, multiplexing)
- S5-compatible communication (SEND/RECEIVE)
• Easy configuration and programming over PROFIBUS
• Cross-network programming device communication through
S7 routing
• Modules can be replaced without the need for a PG
■ Technical specifications
Data transmission rate 9.6 Kbit/s to 12 Mbit/s S7 communication
performance data
Interfaces
• Number of usable connections Max. 16
• Connection to PROFIBUS 9-pin Sub-D connector (RS485)
S5-compatible interface
• Connection to supply voltage 4-pin terminal block (SEND/RECEIVE)
Supply voltage 24 V DC • Number of usable connections Max. 16
Current consumption • Useful data/connection Max. 240 byte
• From backplane bus 150 mA (transmit and receive)
■ Overview
• PROFIBUS DP master or slave with optical interface for
connecting the SIMATIC S7-300 and the SIMATIC C7 to
PROFIBUS at up to 12 Mbit/s (including 45.45 kbit/s)
• Direct connection to the optica l PROFIBUS network over the
integrated fiber-optic interface for plastic and PCF fiber-optic
cables
4 • Communication services:
- PROFIBUS DP-V0
- PG/OP communication
- S7 communication (client, server, multiplexing)
- S5-compatible communication (SEND/RECEIVE)
• Easy configuration and programming over PROFIBUS
• Cross-network programming device communication through
S7 routing
• Modules can be replaced without the need for a PG
■ Technical specifications
Data transmission rates 9.6 Kbit/s to 12 Mbit/s Performance data
(exception: 3 and 6 Mbit/s)
S7 communication
Interfaces
• Number of usable connections Max. 16
• Connection to PROFIBUS 2 x duplex sockets
S5-compatible communication
• Connection to supply voltage 4-pin terminal block (SEND/RECEIVE)
Supply voltage 24 V DC • Number of usable connections Max. 16
Current consumption • Useful data/connection Max. 240 byte
(transmit and receive)
• From backplane bus 150 mA
Multi-protocol operation
• From 24 V DC 250 mA
• Number of usable connections 32 (without DP);
Power loss 6.75 W max. 28 (with DP)
Maximum distance between DP master function
2 adiescent network stations
• DP master DP-V0
• Plastic FOC Max. 50 m
• Number of DP slaves 124
• PCF FOC Max. 300 m
• Total size of DP data ranges
Perm. environmental conditions 2160 Byte
- DP input range
• Operating temperature 0°C to +60°C 2160 Byte
- DP output range
• Transport/storage temperature -40 °C to +70 °C
• Size of the DP data ranges per
• Relative humidity Max. 95% at +25 °C connected slave
Design - DP input range 244 Byte
- DP output range 244 Byte
• Module format Compact assembly
• Size of the DP diagnostic data max. 240 Byte
• Dimensions (W x H x D) in mm 40 x 125 x 120 per connected slave
• Weight Approx. 300 g DP slave function
• Number of CPs per S7-300 4 • DP slave DP-V0
• Size of DP data ranges
- DP input range 240 Byte
- DP output range 240 Byte
PG/OP communication
• Number of operable OP connec- 16
tions (acyclic services)
■ Overview
Master connection of SIMATIC S7-300 and SIMATIC C7 to
PROFIBUS up to 12 Mbit/s (incl. 45.45 Kbit/s)
• Communication services:
- PG/OP communication
- S7 communication
- S5-compatible communication (SEND/RECEIVE)
4 - PROFIBUS FMS
• Simple configuration and programming using PROFIBUS
• Easily integrated into the S7-300 system
• PG communication between networks through S7 routing
• Module changeover without PG
■ Technical specifications
Data transmission rate 9.6 kbit/s to 12 Mbit/s Performance data for S7 commu-
nication
Interfaces
• Number of connections that can max. 16 1)
• Connection to PROFIBUS 9-pin Sub-D socket (RS 485) be used
• Connection to supply voltage 4-pin terminal block Performance data for S5-compa-
Power supply 24 V DC tible interface (SEND/RECEIVE)
• Number of connections that can max. 16
Current consumption be used
• From backplane bus 150 mA • Useful data / connection max. 240 bytes
(SEND and RECEIVE)
• from 24 V 250 mA
Performance data
Power loss 6.75 W
for FMS function
Perm. ambient conditions • Number of connections that can Max. 16
• Operating temperature 0 °C to +60 °C be used
• Transport/storage temperature -40 °C to +70 °C Variable length for READ 237 bytes
• Relative humidity Max. 95% at +25°C Variable length for 233 bytes
Construction WRITE and REPORT
• Module format Compact module Configurable server variables 256
• Dimensions (WxHxD) in mm 40 x 125 x 120 Variables that can be loaded from 256
• Weight Approx. 300 g partners
Number of CPs per S7-300 4 Multi-protocol operation
• Number of connections Max. 48
that can be used
1) Dependent on the CPU used
■ Overview
• Interface for the SIMATIC S7-300 to Industrial Ethernet
- 10/100 Mbit/s full/half duplex connection with Autosensing
for automatic switchover
- RJ45 connection
- Multi-protocol operation with TCP and UDP transport protocol
- Keep Alive function
4 • Communication services:
- TCP/IP und UDP transport protocol
- PG/OP communication
- S7 communication (server)
- S5-compatible communication
• Multicast for UPD
• Remote programming and initial start-up is possible exclusi-
vely over Industrial Ethernet
• Integration into networ k management through SNMP
• Configuration of CP 343-1 Lea n with NCM S7 for Industrial
Ethernet (integrated into STEP 7)
• Cross-network programming device/operator panel communi-
cation through S7 routing
■ Technical specifications
Data transmission rate 10/100 Mbit/s autosensing Performance data
Interfaces S5-compatible communication
• 10BaseT, 100BaseTX RJ45 (SEND/RECEIVE)
• Connection for power supply 2-pin plug-in terminal strip • Sum of all simultaneously operable Max. 8
TCP/UDP connections
Power supply +5 V DC (±5%) and +24 V
DC (±5%) • Useful data
Current consumption - TCP 8 KB
• From backplane bus 200 mA - UDP 2 KB
• From 24 V DC external Typ. 160 mA S7 communication
Max. 200 mA
• Number of connections Max. 4
Power loss 5.8 W
PG/OP communication
Perm. ambient conditions
• Number of operable OP connec- Max. 4
• Operating temperature 0 °C to +60 °C tions (non-isochrone services)
• Transport/storage temperature -40 °C to +70 °C Multi-protocol operation
• Relative humidity Max. 95% at +25 °C • Sum of all simultaneously Max. 12
Construction operable connections
• Module format Compact module S7-300, single Multicast 8
width
• Dimensions (W x H x D) in mm 40 x 125 x 120
• Weight Approx. 200 g
Configuring software NCM S7 for Industrial Ethernet
(supplied with STEP 7 V5.2)
■ Overview
• Connection of SIMATIC S7-300 to Industrial Ethernet
- 10/100 Mbit/s full/half duplex connection with Autosensing
for automatic switchover
- Connection for RJ45
- Multi-protocol operation with TCP and UDP transport proto-
col
4 - Adjustable Keep Alive function
• Communication services:
- TCP/IP und UDP transport protocol
- PG/OP communication
- S7 communication (client, server, multiplexing)
- S5-compatible communication
• Multicast for UPD
• Remote programming and init ial startup via the network
• SNMP-supported diagnostics
• Configuration of CP 343-1 wi th the NCM S7 options package
for Industrial Ethernet (integrated into STEP 7)
• Cross-network programming device/operator panel communi-
cation through S7 routing
■ Technical specifications
Data transmission rate 10/100 Mbit/s autosensing Performance data
Interfaces S5-compatible communication
(SEND/RECEIVE)
• 10BaseT, 100BaseTX RJ45
• Sum of all simultaneously Max. 16
• Connection for power supply 2-pin plug-in terminals operable TCP/UDP connections
Supply voltage +5 V DC (±5%) and +24 V • Useful data
DC (±5%)
- TCP 8 KB
Current consumption
- UDP 2 KB
• From backplane bus 200 mA
S7 communication
• From external 24 V DC Typ. 160 mA
Max. 200 mA • Number of connections Max. 16
Power loss 5.8 W PG/OP communication
Perm. environmental conditions • Number of operable 16
OP connections
• Operating temperature 0 °C to +60 °C (acyclic services)
• Transport/storage temperature -40 °C to +70 °C Multi-protocol operation
• Relative humidity Max. 95% at +25 °C • Sum of all simultaneously operable Max. 48
Design connections
• Module format Compact module S7-300, double Multicast 16
width
• Dimensions (W x H x D) in mm 80 x 125 x 120
• Weight Approx. 600 g
Configuration software NCM S7 for Industrial Ethernet
(supplied with STEP 7 V5.2 )
■ Overview
• Connection of SIMATIC S7-300 to Industrial Ethernet
- 10/100 Mbit/s full/half duplex connection with autosensing
- Connection via RJ45
- Multi-protocol operation for TCP/IP and UDP
- Adjustable Keep Alive function
• Communication services:
4 - TCP/IP und UDP transport protocol
Multicast for UDP
- Programming device/operator panel communication:
Network-wide PG/OP communication through S7 Routing
- S7 communication
- S5-compatible communication
- IT communication:
HTTP communication supports access to process data
through Web browsers;
FTP communication supports program-controlled FTP client
communication,
Access to data blocks through FTP server,
Data handling for own file system through FTP,
E-mail
• IP address assignment via DHCP, simple PC tool or via
program block per HMI (in exclusive server mode)
• IP address-based access protection
• Remote programming and init ial startup via the network
• Clock synchronization of the CPU via NTP or SIMATIC
procedure
• Integration into network ma nagement systems through the
support of SNMP V1 MIB-II
■ Technical specifications
Data transmission rate 10/100 Mbit/s autosensing Performance data
Interfaces IT communication
• 10BaseT, 100BaseTX RJ45 Number of connections Max. 1
to an e-mail server
• Connection for power supply 2-pin terminal block
Memory capacity
Power supply +5 V DC (±5%) and
• Flash Memory file system 30 MB
+24 V DC (±5%)
• RAM memory 30 MB
Current consumption
Service life of the Flash Memory 70.000 write cycles
• From backplane bus 200 mA cells
• From 24 V DC external Max. 200 mA S5-compatible communication
Power loss 6W (SEND/RECEIVE)
• Sum of all simultaneously operable Max. 16
Perm. ambient conditions TCP/UDP connections
• Operating temperature 0 °C to +60 °C • Useful data
• Transport/storage temperature –40 °C to +70 °C - TCP Max. 8 KB
• Relative humidity Max. 95% at +25 °C - UDP Max. 2 KB
- E-mail: Max. 2 KB
Construction
S7 communication
• Module format Compact module S7-300, 1)
double width • Number of connections Max. 16
• Dimensions (WxHxD) in mm 80 x 125 x 120 Programming device/operator
panel communication
• Weight Approx. 600 g
• Number of operable OP connec- Max. 16
Configuring software NCM S7 for Industrial Ethernet tions (non-isochrone services)
(supplied with STEP 7 V5.x)
FTP communication
• Number of client connections Max. 10
• Number of server connections Max. 2
HTTP communication
• Number of connections Max. 4
Multi-protocol operation
• Sum of all simultaneously operable Max. 48
connections
■ Overview
• The CP 343-1 PN enables conn ection of SIMATIC S7-300 to
Industrial Ethernet
- 10/100 Mbit/s full/half duplex connection with autosensing
for automatic switching
- Universal connection options for ITP, RJ45 and AUI
- Adjustable Keep Alive function
4 - TCP/UDP transport protocol
• PROFINET communications standards: PROFINET, the Ether-
net-based communications standard, defines an engineering
model for distributed automation solutions and a model for
system-wide communication through PROFIBUS and Indus-
trial Ethernet. This standard is implemented by Siemens as
Component based Automation.
• Additional communication services:
- PG/OP communication
- S7 communication
- S5-compatible communication
• Multicast at UDP
• Remote programming and commissioning through the
network
■ Technical specifications
Data transmission rate 10/100 Mbit/s autosensing Performance data
Interfaces PROFINET communication
• Connection to Industrial Ethernet 15-pin Sub-D connector • No. of communications partners Max. 64
- AUI (10 Mbit/s) • Number of connections Max. 256
- ITP (10/100 Mbit/s) S5-compatible communication
• 10Base/100BaseT RJ45 • Sum of all simultaneously Max. 16
operable TCP/UDP
• Connection for power supply 4-pin terminal block connections
Supply voltage +5 V DC (±5%) and • Useful data
+24 V DC (±5%)
• TCP Max. 8 Kbytes
Current consumption
• UDP Max. 2 Kbytes
• From backplane bus 70 mA
S7 and PG/OP communication
• From external 24 V DC Typ. 400 mA
Max. 580 mA • Number of connections 1) Max. 16
(depending on the interface
used) Multi-protocol operation
■ Benefit
• Simple plug connections fo r front connector module,
cable and terminal block
• Fast, low-cost wiring
• Power supply for digital and analog signals can be connected
to the front connector module or terminal block
• Preliminary detent position of front connector modules for
activation (only with 20-pole front connector modules)
4
• Reduction in wiring faults, clear control cabinet wiring
• Byte-oriented distribution of digital signals
• Each component can be replaced individually
• Any cable length can be configured without waste
■ Technical specifications
Technical specifications for front connector module Terminal blocks with relay 8S
Rated operating voltage 24 V DC Energizing side
Max. permitted operating voltage DC 60 V Operating voltage for coil DC 24 V
Max. permitted continuous current Input circuit none
• per connector pin 1A Contact side
Max. permitted summation current 4 A/byte Number of relay outputs 8 (NO contact)
Permissible ambient air 0 to + 60 °C Contact design Single contact, 1 NO contact
temperature
Breaking capacity max. 2 A/250 V AC,
Test voltage 0.5 kV, 50 Hz, 60 s (resistance load) max. 2 A/30 V DC
max. 0.2 A/60 V DC
Air and creepage distances IEC 664 (1980), IEC 664 A (1981), recommended minimum
in accordance with DIN VDE 0110 load ≥ 100 mA
(01.89),
overvoltage class II, Switching frequency 6 cycles/minute
pollution degree 2
Service life
Technical specifications for 16-pin and 2 x 16-pin SIMATIC S7 • mechanical 10 x 106 make-break operations
round-sheath ribbon cable on terminal block • electrical 600 x 103 make-break operations
Operating voltage DC 60 V at 230 V AC/2 A/ cos φ = 1
Max. aggregate current 4 A/byte Mounting position horizontal, ventilation slots at the
top and bottom.
Operating temperature 0 to + 60 °C A space of at least 30 mm must
be left above and below the relay
External diameter in mm approx. 9.5/11.5
terminal block for cooling.
for 16-pin/2 x 16-pin
Air and creepage distances IEC 1131-2 (1992), EN 50 178
Terminal blocks for 1-wire connection and 3-wire initiators (4/98) overvoltage category III,
pollution degree 2 between cont-
Max. operating voltage DC 60 V rol circuit and relay contact:
5.5 mm between contact groups
Continuous current per signal 1A K0-K3 and K4-K7:
Max. aggregate current 4 A/byte 5.5 mm within a contact group :
(power supply) 3.2 mm UL and CSA in
preparation
Operating temperature 0 to + 60 °C
Connection blocks removable for
Mounting position any permanent wiring
Air and creepage distances IEC Report 664, IEC 664 A, • for 24 V infeed for supply of digital 4-pin connection block
IEC 1131 T2, modules
CSA C22.2 No 142 UL 508,
VDE 0160 (12.90), • for relay outputs two 8-pin connection blocks
overvoltage class II, Dimensions (W x H x D) in mm approx. 60 x 68 x 78
pollution degree 3 6ES7924-0CD00-_A_0
Dimensions (W x H x D) in mm
• 1-wire connection approx. 51 x 41 x 55
6ES7924-0AA00-_A_0
• for 3-wire initiators approx. 60 x 41 x 70
6ES7924-0CA00-_A_0
■ Benefit
The flexible connection ensures that there is a fast and direct
connection between the input/output modules of the SIMATIC
S7-300 and the individual elements in the switchgear cabinet.
Single cores aleady attached reduce wiring overheads.
• Individual cores can be routed directly to each element in the
4 control cabinet.
• Higher currents are possible usin g a larger cross-section, with
a smaller voltage drop.
• Reduction in the wiring overhead through simple plugging-on
of the preassembled cable onto the I/O module
• Simple wiring. The number printe d on the core corresponds to
the connection point on the I/O connector
• Clear control cabinet wiring thanks to bundled individual
cores
■ Technical specifications
Front connector with single cores, 16 channels Front connector with single cores, 32 channels
Rated operating voltage DC 24 V Rated operating voltage DC 24 V
Permissible continuous current if 1.5 A Permissible continuous current if all 1.5 A
all cores carry load simultaneously, cores carry load simultaneously,
max. max.
Permissible ambient air tempera- 0 to 60 °C Permissible ambient air 0 to 60 °C
ture temperature
Number of single cores 20 Number of single cores 40
Core type H05V-K or with UL 1007/1569; Core type H05V-K or with UL 1007/1569;
CSA TR64 CSA TR64
Conductor cross-section 0.5 mm2; Cu Conductor cross-section 0.5 mm2; Cu
Bundle diameter in mm approx. 15 Bundle diameter in mm approx. 17
Color of core blue, RAL 5010 Color of core blue, RAL 5010
Designation of the cores numbered consecutively Designation of the cores numbered consecutively
from 1 to 20 from 1 to 40
(front connector contact = num- (front connector contact = core
ber of core) number)
Assembly Screw or crimp contacts Assembly Screw or crimp contacts
■ Overview
• For connecting the racks in multitier SIMATIC S7-300
configurations
• IM 365: For configuring a cent ral controller and up to one
expansion rack
• IM 360/IM 361: For configuring a central controller and up to
4 three expansion racks
■ Technical specifications
6ES7 360-3AA01-0AA0 6ES7 361-3CA01-0AA0 6ES7 365-0BA01-0AA0
Supply voltages
Rated value
- 24 V DC Yes
Current consumption
• from backplane bus 5 V DC, max. 350 mA 100 mA
• from supply voltage L+, max. 500 mA
• Power dissipation, typical 2W 5W 0.5 W
Configuration
• Number of interface modules per 1 3 1; 1 pair
CPU, max.
Dimensions and weight
• Weight, approx. 225 g 505 g 580 g
• Width 40 mm 80 mm 40 mm
• Height 125 mm 125 mm 125 mm
• Depth 120 mm 120 mm 120 mm
■ Overview
• Load power supplies for S7-300/ET 200M
• For conversion of the line voltag e to the required operating vol-
tage of 24 V DC
■ Technical specifications
Power supply, type 2A 2A 5A 5A 10 A
Order No. 6ES7 307-1BA00- 6ES7 305-1BA80- 6ES7 307-1EA00- 6ES7 307-1EA80- 6ES7 307-1KA01-
0AA0 0AA0 0AA0 0AA0 0AA0
Overvoltage resistance 2.3 x Ue rated, 1.3 ms 154 V; 0.1 s 2.3 x Ue rated, 1.3 ms 2.3 x Ue rated, 1.3 ms 2.3 x Ue rated, 1.3 ms
Mains buffering at Ie rated > 20 ms at Ue = > 10 ms at Ue rated > 20 ms at Ue = > 20 ms at Ue = > 20 ms at Ue =
93/187 V 93/187 V 93/187 V 93/187 V
Mains frequency rated value; 50/60 Hz, - 50/60 Hz; 50/60 Hz, 50/60 Hz,
range 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz
Rated current Ie rated 0.9/0.6 A 2.7-0.6 A (4-0.9 A) 2.1/1. 3 A 2.1/1.2 A 2.1/1.2 A
Inrush current limiting < 20 A, < 3 ms < 20 A, < 10 ms < 45 A, < 3 ms < 45 A, < 3 ms < 45 A, < 3 ms
(+25 °C)
I2t < 1.0 A2s < 5 A2s < 1.2 A2s < 1.8 A2s < 1.8 A2s
(typ. 1.2 A2s) (typ. 1.2 A2s)
Installed input fuse T 1.6 A/250 V T 6.3 A/250 V F 4 A/250 V T 3.15 A/250 V T 3.15 A/250 V
(not accessible) (not accessible) (not accessible) (not accessible) (not accessible)
Recommended miniature circuit- 3A, characteristic C 10A and above, 6 A and above, 10 A and above, 10 A and above,
breaker (IEC 898) in the main characteristic C characteristic C characteristic C or 6 characteristic C or 6
supply conductor DC-compatible A and above, A and above,
characteristic D characteristic D
1) SIPLUS module for extended temperature range ñ 25 to + 60 ×C and for use under medium loading (e.g. atmospheres containing a high concentration of
chlorine and sulphur ). Currently being prepared for conformity with EN 50155 (for electrical equipment on railway vehicles).
Adjustment range - - - - -
Status display Green LED for 24 V Green LED for 24 V Green LED for 24 V Green LED for 24 V Green LED for 24 V
O.K. O.K. O.K. O.K. O.K.
Startup delay/ < 3 s / typ. 60 ms < 3 s (typ. 7 ms)/ < 2 s (typ. 60 ms) < 3 s/typ. 100 ms < 3 s/typ. 100 ms
voltage rise typ. 5 ms
Efficiency
Efficiency at Ua rated, Ia rated approx. 83 % approx. 75% approx. 87 % approx. 84 % approx. 84 %
Power loss at Ua rated, Ia rated approx. 10 W approx. 16 W (24 W) approx. 18 W approx. 23 W approx. 23 W
Control
Dynamic mains compensation ± 0.3 % Ua ± 0.3 % Ua ± 0.3 % Ua ± 0.3 % Ua ± 0.3 % Ua
(Ua rated ±15 %)
Dynamic load compensation ± 0.8 % Ua ± 2.5 % Ua ± 2.5 % Ua ± 3 % Ua ± 3 % Ua
(Ia: 50/100/50 %)
Load step settling time
• 50 to100 % < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) typ. 0.1 ms < 5 ms (typ. 0.2 ms) < 5 ms (typ. 0.2 ms)
• 100 to 50 % < 5 ms (typ. 2.5 ms) < 5 ms (typ. 2.5 ms) typ. 0.1 ms < 5 ms (typ. 0.2 ms) < 5 ms (typ. 0.2 ms)
Protection and monitoring
Output overvoltage protection Additional control Additional control Additional control Additional control Additional control
loop, shutdown at loop, shutdown at loop, shutdown at loop, shutdown at loop, shutdown at
approx.30V, approx.30V, approx.30V, approx.30V, approx.30V,
automatic cold automatic cold automatic cold automatic cold automatic cold
restart restart restart restart restart
Current limit 2.2 to 2.6 A 3.3 to 3.9 A 5.5 to 6.5 A 5.5 to 6.5 A 5.5 to 6.5 A
Short-circuit protection Electronic shut- Electronic shut- Electronic shut- Electronic shut- Electronic shut-
down, automatic down, automatic down, automatic down, automatic down, automatic
cold restart cold restart cold restart cold restart cold restart
Continuous r.m.s. <4A <2A <9A <5A <5A
short-circuit current
Overload/short-circuit indication - - - - -
1) SIPLUS module for extended temperature range ñ 25 to + 60 ×C and for use under medium loading (e.g. atmospheres containing a high concentration of
chlorine and sulphur ). Currently being prepared for conformity with EN 50155 (for electrical equipment on railway vehicles).
Marine approvals In the S7-300 Yes, GL, LRS In the S7-300 Yes, GL, LRS Yes, GL, LRS
system system
Degree of protection (EN 60529) IP20 IP20 IP20 IP20 IP20
EMC
Emitted interference EN 55022 Class B EN 55011 Class A EN 55022 Class B EN 55011 Class A EN 55011 Class A
Limiting of mains harmonics Not applicable Not applicable EN 61000-3-2 - -
Immunity to interference EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
Operating data
Ambient temperature range 0 to +60 °C with nat- - 25 to + 70 °C with 0 to +60 °C with nat- - 25 to + 70 °C with - 25 to + 70°C with
ural convection natural convection ural convection natural convection natural convection
Transport and storage -40 to +85 °C -40 to +85 °C -40 to +85 °C -40 to +85 °C -40 to +85 °C
temperature range
Humidity class Climate Class 3K3 Climate Class 3K5 Climate Class 3K3 Climate Class 3K5 Climate Class 3K5
acc. to EN60721, acc. to EN60721, acc. to EN60721, acc. to EN60721, acc. to EN60721,
without condensa- short-term conden- without condensa- short-term conden- short-term conden-
tion sation permissible tion sation permissible sation permissible
Mechanical system
Connections
• Mains input L, N, PE One screw-type One screw-type One screw-type One screw-type One screw-type
(DC input: L+1, M1, PE) terminal each for terminal each for terminal each for terminal each for terminal each for
0.5 to 2.5 mm2 0.5 to 2.5 mm2 0.5 to 2.5 mm2 0.5 to 2.5 mm2 0.5 to 2.5 mm2
solid/stranded solid/stranded solid/stranded solid/stranded solid/stranded
• Output L+ 2 screw-type 3 screw-type 3 screw-type 3 screw-type 3 screw-type
terminals for 0.5 to terminals for 0.5 to terminals for 0.5 to terminals for 0.5 to terminals for 0.5 to
2.5mm2 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2
• Output M 2 screw-type 3 screw-type 3 screw-type 3 screw-type 3 screw-type
terminals for 0.5 to terminals for 0.5 to terminals for 0.5 to terminals for 0.5 to terminals for 0.5 to
2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2
Dimensions (W x H x D) in mm 50 x 125 x 120 80 x 125 x 120 80 x 125 x 120 80 x 125 x 120 80 x 125 x 120
Weight, approx. 0.42 kg 0.75 kg 0.74 kg 0.57 kg 0.57 kg
Mounting For snapping on to For snapping on to For snapping on to For snapping on to For snapping on to
S7 rails S7 rails S7 rails S7 rails S7 rails
Accessories Mounting adapter Mounting adapter Mounting adapter Mounting adapter Mounting adapter
for standard rails for standard rails for standard rails for standard rails for standard rails
and power connec- and power connec- and power connec- and power connec- and power connec-
tor PS-CPU tor PS-CPU tor tor tor
1) SIPLUS module for extended temperature range ñ 25 to + 60 ×C and for use under medium loading (e.g. atmospheres containing a high concentration of
chlorine and sulphur ). Currently being prepared for conformity with EN 50155 (for electrical equipment on railway vehicles).
5/70 Communication
5/70 CP 440
5/71 CP 441-1, CP 441-2
5/73 CP 443-5 Basic
5/75 CP 443-5 Extended
5/77 CP 443-1
5/79 CP 443-1 Advanced
5/81 CP 443-1 IT
5/83 CP 444
Siemens ST 70 · 2005
SIMATIC S7-400
SIMATIC S7-400
Introduction
S7-400
■ Overview
SIMATIC S7-400H
■ Overview CPU 412-1, CPU 412-2 ■ Overview CPU 416-2, CPU 416-3
• The low-cost starter solution for the medium performance range • The powerful CPU for the high-end performance range
• Can be used in small and medi um-sized systems with require- • For installations with the de manding requirements of the
ments of the medium performance range high-end performance range
• With one slot for IF module
• The CPUs for special demands in the mid performance range • The most powerful SIMATIC S7-400 CPU
• Can be used in systems with additional requirements with • Can be used in the most soph isticated installations in the
respect to program scope and command processing rate upper performance range
• With two slots for IF modules
■ Technical specifications
6ES7 412-1XF04-0AB0 6ES7 412-2XG04-0AB0 6ES7 414-2XG04-0AB0 6ES7 414-3XJ04-0AB0
Product version
• Firmware version V4.0 V4.0 V4.0 V4.0
• Associated programming as of STEP7 V 5.2 SP1 as of STEP7 V 5.2 SP1 as of STEP7 V 5.2 SP1 as of STEP7 V 5.2 SP1
package HF3 with HW-Update HF3 with HW-Update HF3 with HW-Update HF3 with HW-Update
Supply voltages
Rated value
- 24 V DC Yes Yes Yes Yes
Voltages and currents
• Incoming supply of external
backup voltage to the CPU
5 to 15 V DC 5 to 15 V DC 5 to 15 V DC 5 to 15 V DC
5
Current consumption
• from backplane bus 5 V DC, max. 0.7 A 1.2 A 1.2 A 1.2 A
• Power dissipation, typical 3W 4.5 W 4.5 W 4.5 W
Back-up battery
- Backup current, max. 890 µA 890 µA 550 µA 1,530 µA
- Backup current, typical 350 µA 350 µA 1,530 µA 550 µA
Memory/backup
Memory
• Working memory
- integrated (for program) 72 KByte 128 KByte 256 KByte 700 KByte
- integrated (for data) 72 KByte 128 KByte 256 KByte 700 KByte
- expandable No No No No
• Load memory
- expandable FEPROM Yes; with Memory Card Yes; with Memory Card Yes; with Memory Card Yes; with Memory Card
(FLASH) (FLASH) (FLASH) (FLASH)
- expandable FEPROM, max. 64 MByte 64 MByte 64 MByte 64 MByte
- integral RAM, max. 256 KByte 256 KByte 256 KByte 256 KByte
- expandable RAM Yes; with Memory Card Yes; with Memory Card Yes; with Memory Card Yes; with Memory Card
(RAM) (RAM) (RAM) (RAM)
- expandable RAM, max 16 MByte 16 MByte 16 MByte 16 MByte
Backup
- available Yes Yes Yes Yes
- with battery Yes; all data Yes; all data Yes; all data Yes; all data
- without battery No No No No
CPU/blocks
DB
- Number, max. 512; DB 0 reserved 512; DB 0 reserved 4,095; DB 0 reserved 4,095; DB 0 reserved
- Size, max. 64 KByte 64 KByte 64 KByte 64 KByte
FB
- Number, max. 256 256 2,048 2,048
- Size, max. 64 KByte 64 KByte 64 KByte 64 KByte
FC
- Number, max. 256 256 2,048 2,048
- Size, max. 64 KByte 64 KByte 64 KByte 64 KByte
OB
- Number, max. see instruction list see instruction list see instruction list see instruction list
- Size, max. 64 KByte 64 KByte 64 KByte 64 KByte
Nesting depth
- per priority class 24 24 24 24
- additional levels within an 1 1 1 1
error OB
CPU/processing times
• for bit instruction, min. 0.1 µs 0.1 µs 0.06 µs 0.06 µs
• for word instruction, min. 0.1 µs 0.1 µs 0.06 µs 0.06 µs
• for integer math, min. 0.1 µs 0.1 µs 0.06 µs 0.06 µs
• for floating-point math, min. 0.3 µs 0.3 µs 0.18 µs 0.18 µs
5 - preset
• Counting range
Z 0 to Z 7 Z 0 to Z 7 from Z 0 to Z 7 from Z 0 to Z 7
- lower limit 0 0 0 0
- upper limit 999 999 999 999
IEC counter
- available Yes Yes Yes Yes
- Type SFB, unlimited quantity SFB, unlimited quantity SFB, unlimited quantity SFB, unlimited quantity
(only limited by working (only limited by working (only limited by working (only limited by working
memory) memory) memory) memory)
S7 times
- Number 2,048 2,048 2,048 2,048
• Retentivity
- adjustable Yes Yes Yes Yes
- lower limit 0 0 0 0
- upper limit 2,047 2,047 2,047 2,047
- preset no timers retentive no timers retentive no timers retentive no timers retentive
• Timing range
- lower limit 10 ms 10 ms 10 ms 10 ms
- upper limit 9,990 s 9,990 s 9,990 s 9,990 s
IEC timer
- available Yes Yes Yes Yes
- Type SFB, unlimited quantity SFB, unlimited quantity SFB, unlimited quantity SFB, unlimited quantity
(only limited by working (only limited by working (only limited by working (only limited by working
memory) memory) memory) memory)
Data areas and their retentive
characteristics
• Retentive data area as a whole total working and total working and total working and total working and
load memory load memory load memory load memory
(with backup battery) (with backup battery) (with backup battery) (with backup battery)
Flags
- Number 4 KByte 4 KByte 8 KByte 8 KByte
- adjustable retentivity Yes; from MB 0 to Yes; from MB 0 to Yes; from MB 0 to Yes; from MB 0 to
MB 4095 MB 4095 MB 8191 MB 8191
- Number of clock memories 8; (1 memory byte) 8; (1 memory byte) 8; (1 memory byte) 8; (1 memory byte)
Address area
I/O address area
- Inputs 4 KByte 4 KByte 8 KByte 8 KByte
- Outputs 4 KByte 4 KByte 8 KByte 8 KByte
• of which distributed
- MPI/DP interface, inputs 2 KByte 2 KByte 2 KByte 2 KByte
- MPI/DP interface, outputs 2 KByte 2 KByte 2 KByte 2 KByte
- DP interface, inputs 4 KByte 6 KByte 6 KByte
- DP interface, outputs 4 KByte 6 KByte 6 KByte
Process image
- Inputs, adjustable 4 KByte 4 KByte 8 KByte 8 KByte
- Outputs, adjustable 4 KByte 4 KByte 8 KByte 8 KByte
- Inputs, preset 128 Byte 128 Byte 256 Byte 256 Byte
- Outputs, preset 128 Byte 128 Byte 256 Byte 256 Byte
- Number of component process 15 15 15 15
images, max.
- Access to consistent data in the Yes Yes Yes Yes
process image
- Consistent data, max. 244 Byte 244 Byte 244 Byte 244 Byte
5 • Statuses
Test and startup functions
Yes Yes Yes Yes
Status/modify
- Variable Yes Yes Yes Yes
Forcing
- Forcing Yes Yes Yes Yes
• Status block Yes Yes Yes Yes
• Single step Yes Yes Yes Yes
• Number of breakpoints 4 4 4 4
Diagnostic buffer
- available Yes Yes Yes Yes
- Number of inputs, max. 200 400 400 3,200
- adjustable Yes Yes Yes Yes
- preset 120 120 120 120
Communication functions
• PG/OP communication Yes Yes Yes Yes
• Routing Yes Yes Yes Yes
Global data communication
- supported Yes Yes Yes Yes
- Size of GD packets, max. 64 Byte 64 Byte 64 Byte 64 Byte
S7 basic communication
- supported Yes; in MPI mode: via SFC Yes; in MPI mode: via SFC Yes; in MPI mode: via SFC Yes; in MPI mode via: SFC
X_SEND, X_RCV, X_GET X_SEND, X_RCV, X_GET X_SEND, X_RCV, X_GET X_SEND, X_RCV, X_GET
and X_PUT and X_PUT and X_PUT and X_PUT
in DP master mode: via in DP master mode: via in DP master mode: via in DP master mode: via
SFC I_GET and I_PUT SFC I_GET and I_PUT SFC I_GET and I_PUT SFC I_GET and I_PUT
- User data per job 76 Byte 76 Byte 76 Byte 76 Byte
S7 communication
- supported Yes Yes Yes Yes
- as server Yes Yes Yes Yes
- as client Yes Yes Yes Yes
- User data per job, max. 64 KByte 64 KByte 64 KByte 64 KByte
S5 compatible communication
- supported Yes; via FC AG_SEND Yes; via FC AG_SEND Yes; via FC AG_SEND Yes; via FC AG_SEND
and AG_RECV, via a and AG_RECV, via a and AG_RECV, via a and AG_RECV, via a
maximum of 10 CP 443-1 maximum of 10 CP 443-1 maximum of 10 CP 443-1 maximum of 10 CP 443-1
or 443-5 or 443-5 or 443-5 or 443-5
- User data per job, max. 8 KByte 8 KByte 8 KByte 8 KByte
Standard communication (FMS)
- Supported Yes; via CP and loadable Yes; via CP and loadable Yes; via CP and loadable Yes; via CP and loadable
FB FB FB FB
Number of connections
- overall 16 16 32 32
5 - Number, max.
- Size, max.
2,048
64 KByte
2,048
64 KByte
6,144
64 KByte
OB
- Number, max. See instruction list See instruction list See instruction list
- Size, max. 64 KByte 64 KByte 64 KByte
Nesting depth
- per priority class 24 24 24
- additional levels within 2 2 2
an error OB
CPU/processing times
• for bit instruction, min. 0.04 µs 0.04 µs 0.03 µs
• for word instruction, min. 0.04 µs 0.04 µs 0.03 µs
• for integer math, min. 0.04 µs 0.04 µs 0.03 µs
• for floating-point math, min. 0.12 µs 0.12 µs 0.09 µs
Timers/counters and their
retentive characteristics
S7 counter
- Number 2,048 2,048 2,048
• Retentivity
- adjustable Yes Yes Yes
- lower limit 0 0 0
- upper limit 2,047 2,047 2,047
- preset from Z 0 to Z 7 from Z 0 to Z 7 from Z 0 to Z 7
• Counting range
- lower limit 0 0 0
- upper limit 999 999 999
IEC counter
- available Yes Yes Yes
- Type SFB, unlimited quantity SFB, unlimited quantity SFB, unlimited quantity
(only limited by working memory) (only limited by working memory) (only limited by working memory)
S7 times
- Number 2,048 2,048 2,048
• Retentivity
- adjustable Yes Yes Yes
- lower limit 0 0 0
- upper limit 2,047 2,047 2,047
- preset no timers retentive no timers retentive no timers retentive
• Timing range
- lower limit 10 ms 10 ms 10 ms
- upper limit 9,990 s 9,990 s 9,990 s
IEC timer
- available Yes Yes Yes
- Type SFB, unlimited quantity SFB, unlimited quantity SFB, unlimited quantity
(only limited by working memory) (only limited by working memory) (only limited by working memory)
Data areas and their
retentive characteristics
• Retentive data area as a whole total working and load memory total working and load memory total working and load memory
(with backup battery) (with backup battery) (with backup battery)
Flags
- Number 16 KByte 16 KByte 16 KByte
- adjustable retentivity Yes; MB 0 to MB 16383 Yes; MB 0 to MB 16383 Yes; MB 0 to MB 16383
- Number of clock memories 8; (1 memory byte) 8; (1 memory byte) 8; 1 memory byte)
5 - Outputs
- Address areas, max.
244 Byte
32
244 Byte
32
244 Byte
32
- User data per address area, 32 Byte 32 Byte 32 Byte
max.
- User data per address area, of 32 Byte 32 Byte 32 Byte
which consistent, max.
2nd interface
• Physical RS 485 / PROFIBUS RS 485 / PROFIBUS RS 485 / PROFIBUS
• Isolated Yes Yes Yes
Functionality
- DP master Yes Yes Yes
- DP slave Yes Yes Yes
DP master
- Number of connections, max. 32; if a diagnostic repeater is 32; if a diagnostic repeater is 32; if a diagnostic repeater is
used in the chain, this reduces used in the chain, this reduces used in the chain, this reduces
the number of connection the number of connection the number of connection
resources in the chain by 1 resources in the chain by 1 resources in the chain by 1
• Services
- PG/OP communication Yes Yes Yes
- Routing Yes Yes Yes
- S7 basic communication Yes Yes Yes
- S7 communication Yes Yes Yes
- Equidistance support Yes Yes Yes
- Activate/deactivate DP slaves Yes Yes Yes
- Direct data exchange Yes Yes Yes
(lateral communication)
- Transmission rates, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s
- Number of DP slaves, max. 125 125 125
• Address area
- Inputs, max. 8 KByte 8 KByte 8 KByte
- Outputs, max. 8 KByte 8 KByte 8 KByte
• User data per DP Slave
- Inputs, max. 244 Byte 244 Byte 244 Byte
- Outputs, max. 244 Byte 244 Byte 244 Byte
DP slave
• Services
- Routing Yes Yes Yes
- Status/modify Yes Yes Yes
- Programming Yes Yes Yes
- Transmission rates, max. 12 Mbit/s 12 Mbit/s 12 Mbit/s
• Intermediate memory
- Inputs 244 Byte 244 Byte 244 Byte
- Outputs 244 Byte 244 Byte 244 Byte
- Address areas, max. 32 32 32
- User data per address area, 32 Byte 32 Byte 32 Byte
max.
- User data per address area, 32 Byte 32 Byte 32 Byte
of which consistent, max.
• CPU for SIMATIC S7-400H and S7-400F/FH. • CPU for SIMATIC S7-400H and S7-400F/FH.
• Can be used in high availability S7-400H systems • Can be used in high availability S7-400H systems
• Can be used with F-runtime lic ense and F-compatible CPU in • Can be used with F-runtime license and F-compatible CPU in
failsafe S7-400F/FH systems failsafe S7-400F/FH systems
• With integrated PROFIBUS DP master interface • With integrated PROFIBUS DP master interface
• With 2 slots for sync modules • With 2 slots for sync modules
■ Technical specifications
6ES7 414- 6ES7 417- 6ES7 414- 6ES7 417-
4HJ04-0AB0 4HL04-0AB0 4HJ04-0AB0 4HL04-0AB0
Supply voltages Timers/counters and their
Rated value retentive characteristics
- 24 V DC Yes Yes S7 counter
- Number 2,048 2,048
Voltages and currents
• Incoming supply of external 5 to 15 V DC 5 to 15 V DC • Retentivity
backup voltage to the CPU - adjustable Yes Yes
Current consumption - lower limit 0 0
• from backplane bus 5 V DC, max. 2A 1.7 A - upper limit 2,047 2,047
5 • Power dissipation, typical 4.5 W 6W - preset
• Counting range
from Z 0 to Z 7 from Z 0 to Z 7
Back-up battery
- lower limit 0 1
- Backup current, max. 1,530 µA 1,810 µA
- upper limit 999 999
- Backup current, typical 550 µA 600 µA
IEC counter
Memory/backup
- available Yes Yes
Memory
- Type SFB, unlimited SFB, unlimited
• Working memory quantity (only quantity (only
- integrated (for program) 700 KByte limited by wor- limited by wor-
- integrated (for data) 700 KByte king memory) king memory)
- expandable No No S7 times
• Load memory - Number 2,048 2,048
- expandable FEPROM Yes; with Yes; with • Timing range
Memory Card Memory Card - lower limit 10 ms 10 ms
(FLASH) (FLASH) - upper limit 9,990 s 9,990 s
- expandable FEPROM, max. 64 MByte 64 MByte
IEC timer
- integral RAM, max. 256 KByte 256 KByte
- available Yes Yes
- expandable RAM Yes; with Yes; with
- Type SFB, unlimited SFB, unlimited
Memory Card Memory Card
quantity (only quantity (only
(RAM) (RAM)
limited by wor- limited by wor-
- expandable RAM, max 16 MByte 16 MByte king memory) king memory)
Backup Data areas and their retentive
- available Yes Yes characteristics
- with battery Yes; all data Yes; all data Flags
- without battery No No - Number 8 KByte 16 KByte
CPU/blocks - adjustable retentivity Yes; MB 0 to Yes; MB 0 to
MB 8191 MB 16383
DB
Address area
- Number, max. 4,095; DB 0 8,192; DB 0
reserved reserved I/O address area
- Size, max. 64 KByte - Inputs 8 KByte 16 KByte
FB - Outputs 8 KByte 16 KByte
- Number, max. 2,048 6,144 • of which distributed
- Size, max. 64 KByte 64 KByte - MPI/DP interface, inputs 2 KByte 2 KByte
- MPI/DP interface, outputs 2 KByte 2 KByte
FC
- DP interface, inputs 6 KByte 8 KByte
- Number, max. 2,048 6,144
- DP interface, outputs 6 KByte 8 KByte
- Size, max. 64 KByte 64 KByte
Process image
OB
- Inputs, adjustable 8 KByte 16 KByte
- Number, max. See instruction See instruction
list list - Outputs, adjustable 8 KByte 16 KByte
- Size, max. 64 KByte 64 KByte - Inputs, preset 1,024 Byte 1,024 Byte
- Outputs, preset 1,024 Byte 1,024 Byte
Nesting depth
- Number of component process 8 8
- per priority class 24 24 images, max.
- additional levels within 2
an error OB Digital channels
- Inputs 65,536 131,072
CPU/processing times
- Outputs 65,536 131,072
• for bit instruction, min. 0.06 µs 0.03 µs
- Inputs, of which central 65,536 131,072
• for word instruction, min. 0.06 µs 0.03 µs - Outputs, of which central 65,536 131,072
• for integer math, min. 0.06 µs 0.03 µs Analog channels
• for floating-point math, min. 0.18 µs 0.09 µs - Inputs 4,096 8,192
- Outputs 4,096 8,192
- Inputs, of which central 4,096 8,192
- Outputs, of which central 4,096 8,192
5 - Point-to-point connection
DP master
No No
MPI/PROFIBUS DP-master
interface, 2 slots for Sync
modules, slot for memory card,
incl. slot number labels, 2 keys
- Number of connections, max. 32 16
- Number of connections 1 for PG, 1 for 1 for PG, 1 for 4 MB main memory 6ES7 417-4HL01-0AB0
(of which reserved), max. OP OP 20 MB main memory A) 6ES7 417-4HL04-0AB0
• Services RAM memory
- PG/OP communication Yes Yes 2 x 2 MB 6ES7 955-2AL00-0AA0
- S7 basic communication No No
2 x 4 MB 6ES7 955-2AM00-0AA0
- S7 communication No No
RAM memory card
- S7 communication, as client No No
- S7 communication, as server No No 1 MB 6ES7 952-1AK00-0AA0
- Equidistance support No No 2 MB 6ES7 952-1AL00-0AA0
- Activate/deactivate DP slaves No No 4 MB 6ES7 952-1AM00-0AA0
- Direct data exchange No No 8 MB 6ES7 952-1AP00-0AA0
(lateral communication)
- Transmission rates, max. 12 Mbit/s 12 Mbit/s 16 MB A) 6ES7 952-1AS00-0AA0
- Number of DP slaves, max. 96 125; Number FEPROM memory card
of slots,
1 MB 6ES7 952-1KK00-0AA0
max. 2048
2 MB 6ES7 952-1KL00-0AA0
• Address area
- Inputs, max. 8 KByte 8 KByte 4 MB 6ES7 952-1KM00-0AA0
- Outputs, max. 8 KByte 8 KByte 8 MB 6ES7 952-1KP00-0AA0
• User data per DP Slave 16 MB 6ES7 952-1KS00-0AA0
- Inputs, max. 244 Byte 244 Byte 32 MB A) 6ES7 952-1KT00-0AA0
- Outputs, max. 244 Byte 244 Byte
64 MB A) 6ES7 952-1KY00-0AA0
CPU/ programming
MPI cable 6ES7 901-0BF00-0AA0
Programming language
For connecting SIMATIC S7 and
- STEP 7 Yes; V5.0 SP2 Yes; V5.0 SP2 the PG through MPI; length 5 m
- LAD Yes Yes
A) Subject to export regulations: AL: N and ECCN: EAR99H
- FBD Yes Yes
- STL Yes Yes
- SCL Yes Yes
- CFC Yes Yes
- GRAPH Yes Yes
- HiGraph® Yes Yes
• User program protection/ Yes Yes
password protection
Dimensions and weight
• Weight, approx. 1,070 g 1,070 g
• Width 50 mm 50 mm
• Height 290 mm 290 mm
• Depth 219 mm 219 mm
• Required slots 2 2
■ Technical specifications
6ES7 416-2FK02-0AB0 6ES7 416-2FK02-0AB0
Supply voltages Nesting depth
Rated value - per priority class 24
- 24 V DC Yes - additional levels within 2
an error OB
Voltages and currents
• Incoming supply of external 5 to 15 V DC CPU/processing times
backup voltage to the CPU • for bit instruction, min. 0.08 µs
Current consumption • for word instruction, min. 0.08 µs
• from backplane bus 5 V DC, max. 1.6 A
• for integer math, min. 0.08 µs
• Power dissipation, typical 7.5 W
• for floating-point math, min. 0.48 µs
Back-up battery
Timers/counters and their
- Backup current, max. 420 µA retentive characteristics
- Backup current, typical 40 µA S7 counter
Memory/backup - Number 512
Memory • Retentivity
• Working memory - adjustable Yes
- expandable No - lower limit 0
• Load memory - upper limit 511
- expandable FEPROM Yes; with Memory Card (FLASH) - preset from Z 0 to Z 7
- expandable FEPROM, max. 64 MByte • Counting range
- integral RAM, max. 256 KByte - lower limit 1
- expandable RAM Yes; with Memory Card (RAM) - upper limit 999
- expandable RAM, max 64 MByte
IEC counter
Backup - available Yes
- available Yes - Type SFB, unlimited quantity (only
- with battery Yes; all data limited by working memory)
- without battery No S7 times
CPU/blocks - Number 512
DB • Retentivity
- Number, max. 4,095; DB 0 reserved - adjustable Yes
- Size, max. 64 KByte - preset no timers retentive
FB • Timing range
- Number, max. 2,048 - lower limit 10 ms
- Size, max. 64 KByte - upper limit 9,990 s
FC
IEC timer
- Number, max. 2,048
- available Yes
- Size, max. 64 KByte
- Type SFB, unlimited quantity (only
OB limited by working memory)
- Number, max. see instruction list
- Size, max. 64 KByte
■ Overview
• For connecting the two 414-4H/417-4H CPUs in the S7-400H
subunits
• Can be plugged directly into the CPU
■ Technical specifications
6ES7 960-1AA00-0XA0
Current consumption
• from CPU, max. 500 mA; from interface 5 V
• Power dissipation, typical 2.5 W
Dimensions and weight
• Weight, approx. 60 g
■ Overview
• For connecting distribute d I/Os using PROFIBUS DP
• Transmission rate max. 12 Mbps
• Electrically isolated RS 485 interface
• Connection by means of 9-pin Sub D socket
• One or two PROFIBUS module s can be plugged into each
S7-400 CPU:
- CPU 414-3/416-3: 1 module
- CPU 417-4: 2 modules
■ Technical specifications
6ES7 964-2AA04-0AB0 6ES7 964-2AA04-0AB0
Current consumption DP master
• from CPU, max. 150 mA; Current consumption • Services
from S7-400 bus: the module
does not take up current at 24 V, - PG/OP communication Yes
it merely makes this voltage - Equidistance support Yes
available at the DP interface.
Total current consumption of - SYNC/FREEZE Yes
the components connected to the
DP interface, to a maximum of - Direct data exchange Yes
150 mA. (lateral communication)
■ Overview
• Digital inputs for the SIMATIC S7-400
• For connecting standard switches and two-wire proximity swit-
ches (BERO)
■ Technical specifications
6ES7 421- 6ES7 421- 6ES7 421- 6ES7 421- 6ES7 421-
7BH01-0AB0 1BL01-0AA0 1EL00-0AA0 1FH20-0AA0 7DH00-0AB0
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V
- permissible range, 20.4 V
lower limit (DC)
- permissible range, 28.8 V
upper limit (DC)
Current consumption
• from backplane bus 5 V DC, max. 130 mA 20 mA 200 mA 80 mA 150 mA
• from supply voltage L+, max. 120 mA
• Power dissipation, max. 5W 6W 16 W 12 W 8 W;
6.5 W (48 V DC)
Digital inputs
• Number of digital inputs 16 32 32 16 16
Number of inputs that can be driven
in parallel
- Number of inputs that can be 16 32 32 16 16
driven in parallel, up to 40 °C
- Number of inputs that can be 16 32 32 16 16
driven in parallel, up to 60 °C
Length of cable
- Length of cable shielded, max 1,000 m; 1,000 m 1,000 m 1,000 m 1,000 m
1000 m/3 ms;
70 m/0.5 ms;
30 m/0.1 ms;
30 m/0.05 ms
- Length of cable unshielded, max 600 m; 600 m 600 m 600 m 100 m
600 m/3 ms;
50 m/0.5 ms;
20 m/0.1 ms;
20 m/0.05 ms
Input voltage
- Rated value, DC 24 V 24 V
- Rated value, UC 120 V 120/230 V UC 24 to 60 V UC
- for signal "0" -30 to 5 V DC -30 to 5 V DC 0 to 20 V 0 to 40 V -6 to +6 V DC
0 to 5 V AC
- for signal "1" 11 to 30 V DC 13 to 30 V 79 to 132 V AC 79 to 264 V AC 15 to 72 V DC
80 to 132 V DC 80 to 264 V DC 15 to 60 V AC
- Frequency range 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz
■ Overview
• Digital outputs for the SIMATIC S7-400
• For connecting solenoid va lves, contactors, low-power
motors, lamps and motor starters
■ Technical specifications
6ES7 422- 6ES7 422- 6ES7 422- 6ES7 422- 6ES7 422-
1FH00-0AA0 1HH00-0AA0 1BH11-0AA0 1BL00-0AA0 7BL00-0AB0
Voltages and currents
Load voltage L+
- Rated value (DC) 60 V 24 V 24 V 24 V
- permissible range, 1V 20.4 V 20.4 V 20.4 V
lower limit (DC)
- permissible range, 60 V 28.8 V 28.8 V 28.8 V
upper limit (DC)
Load voltage L1
- Rated value (AC) 120/230 V AC 230 V
- permissible range, 79 V 2V
lower limit (AC)
- permissible range, 264 V 264 V
upper limit (AC)
Current consumption
• from load voltage L+ (no load), 30 mA 30 mA 120 mA
max.
• from load voltage L1 (no load), 6 mA
max.
• from backplane bus 5 V DC, max. 400 mA 1A 160 mA 200 mA 200 mA
• Power dissipation, max. 16 W 25 W 7W 4W 8W
Digital outputs
• Number of digital outputs 16 16; Relay 16 32 32
• Length of cable shielded, max. 1,000 m 1,000 m 1,000 m 1,000 m 1,000 m
• Length of cable unshielded, max. 600 m 600 m 600 m 600 m 600 m
• Short-circuit protection Yes; Fusing Yes; clocking Yes; clocking Yes; clocking
of the output electronically electronically electronically
• Limitation of voltage induced -30 V -27 V L+ (-45 V)
on circuit interruption to
• Lamp load, max. 25 W 10 W 5W 5W
Output voltage
- for 1 signal L1 (-18.1 V) L+ (-0.5 V) L+ (-0.3 V) L+ (-0.8 V)
Output current
- for 1 signal rated value 2A 2A 0.5 A 0.5 A
- for 1 signal permissible range 10 mA 5 mA 5 mA 5 mA
for 0 to 60 °C, min.
- for 1 signal permissible range 2A 2.4 A 0.6 A 0.6 A
for 0 to 60 °C, max.
- for 0 signal residual current, max. 2.6 mA 0.5 mA 0.3 mA 0.5 mA
■ Overview
• Analog inputs for the SIMATIC S7-400
• For connection of voltage and current sensors, thermo-
couples, resistors and resistance thermometers
• Resolution from 13 to 16 bits
■ Technical specifications
6ES7 431-0HH00-0AB0 6ES7 431-1KF00-0AB0 6ES7 431-1KF10-0AB0 6ES7 431-1KF20-0AB0
Voltages and currents
Load voltage L+
- Rated value (DC) 24 V 24 V 24 V
- Reverse polarity protection Yes Yes Yes
Current consumption
• from load voltage L+ (no load), 400 mA 200 mA 200 mA
max.
• from backplane bus 5 V DC, max. 100 mA 350 mA 600 mA 1,000 mA
• Power dissipation, typical 2W 1.8 W 3.5 W 4.9 W
Analog inputs
• Number of analog inputs 16 8 8 8
• Number of analog inputs for 16 8 8 8
voltage/current measurement
• Number of analog inputs 4 4 4
for resistance measurement
• Length of cable shielded, max 200 m 200 m 200 m; 50 m for thermo- 200 m
couples and input ranges
<= 80 mV
• Permissible input voltage for the 20 V 50 V 18 V 18 V
voltage input (destruction limit),
max.
• Permissible input voltage for the 40 mA 50 mA 40 mA 54 mA
current input (destruction limit),
max.
Input ranges (rated values),
voltages
- 1 to +5 V Yes Yes Yes Yes
- -1 V to +1 V Yes Yes Yes Yes
- -10 V to +10 V Yes Yes Yes Yes
- -2.5 V to +2.5 V Yes
- -250 mV to +250 mV Yes
- -5 V to +5 V Yes
- -500 mV to +500 mV Yes
- -80 mV to +80 mV Yes
Input ranges (rated values),
currents
- 0 to 20 mA Yes
- -20 to +20 mA Yes Yes Yes
- 4 to 20 mA Yes Yes Yes Yes
■ Overview
• Analog outputs for the SIMATIC S7-400
• For the connection of analog actuators
■ Technical specifications
6ES7 432-1HF00-0AB0 6ES7 432-1HF00-0AB0
Voltages and currents Analog value formation
Load voltage L+ Integration and conversion time/
- Rated value (DC) 24 V triggering per channel
- with over-range 13 Bit
Current consumption (bits incl. sign), max
• from backplane bus 5 V DC, 150 mA - Conversion time (per channel) 420 µs
max.
• from supply voltage L+, max. 400 mA Settling time
• Power dissipation, max. 9W - for resistive load 0.1 ms
- for capacitive load 3.5 ms
Analog outputs
- for inductive load 0.5 ms
• Number of analog outputs 8
• Length of cable shielded, max 200 m Error/accuracies
• Voltage output, Yes Operational limit in the entire
short-circuit protection temperature range
• Voltage output, 25 mA - Relative to the output range, +/- 0.5 %
short-circuit current, max voltage
• Current output, 18 V - Relative to the output range, +/- 1 %
open-circuit voltage, max. current
■ Overview
• Two-channel intelligent counte r module for simple counting
tasks
• For direct connection of incremental encoders
• Comparison function with 2 specifiable comparison values
• Integrated digital ou tputs for outputting the response when the
comparison values are reached
Note
SIMODRIVE Sensor/Motion Connect 500 feature incremental
encoders and preassembled connecting cables for counting
5 and positioning functions.
Additional information is available in the Internet under:
http://www.siemens.com/simatic-technology
■ Technical specifications
6ES7 450-1AP00-0AE0 6ES7 450-1AP00-0AE0
Voltages and currents Digital outputs
Auxiliary voltage 1L+, • Number of digital outputs 6
load voltage 2 L+ • Short-circuit protection Yes; clocking electronically
- Rated value (DC) 24 V of the output
- permissible range, 20.4 V; dynamic 18.5 V • Limitation of voltage induced 2L+ (-39 V)
lower limit (DC) on circuit interruption to
- permissible range, 28.8 V; dynamic 30.2 V Output voltage
upper limit (DC)
- for 0 signal (DC), max. 3V
• Non-periodic snap-over - for 1 signal 2L+ (-1.5 V)
- Duration 500 ms
Output current
- Recovery time 50 s
- for 1 signal rated value 0.5 A
- Value 35 V
- for 1 signal permissible range 5 mA
Load voltage 1L+ for 0 to 60 °C, min.
- Reverse polarity protection Yes - for 1 signal permissible range 0.6 A
for 0 to 60 °C, max.
Load voltage 2L+
- Reverse polarity protection Yes Output delay at resistive load
- "0" to "1", max. 300 µs
Current consumption
• from load voltage 1L+ (no load), 40 mA Sensor supply
max. 5 V - sensor supply
• from backplane bus 5 V DC, max. 450 mA - 5V Yes; 5.2 V +/-2%
• Power dissipation, typical 9W - Short-circuit protection Yes
Connection system - Output current, max. 300 mA
• Requisite front connector 1 x 48-pin 24 V - sensor supply
Digital inputs - 24 V Yes; 1L+ (-3V)
• Number of digital inputs 6 - Short-circuit protection Yes
• Functions 1 for gate start, 1 for gate stop, - Output current, max. 300 mA
1 for setting the counter Sensor
Input voltage Connectable encoders
- for signal "0" -28.8 to 5 V - Incremental encoder Yes;
- for signal "1" +11 to +28.8 V (symmetrical) with 2 pulse trains offset by 90°
- Incremental encoder Yes
Input current
(asymmetrical)
- for 1 signal, typical 9 mA
- 24 V initiator Yes
Input delay (at rated value of the - 24 V directional sensor Yes;
input voltage) 1 pulse train, 1 direction level
- Input frequency 200 kHz
(at 0.1 ms delay time), max.
• For standard inputs
- Parameterizable Yes
- at 0 to 1, max. 2.5 µs;
>= 2.5 µs (200 kHz),
<= 25 µs (20 kHz)
■ Overview
• Three-channel positioning modu le for rapid traverse/creep
speed drives
• 4 digital outputs per ch annel for motor control
• Incremental or synchro-serial position decoding
Note
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables for
counting and positioning functions.
Additional information is available in the Internet under:
5 http://www.siemens.com/simatic-technology
■ Technical specifications
6ES7 451-3AL00-0AE0 6ES7 451-3AL00-0AE0
Supply voltages Sensor supply
Rated value 5 V - sensor supply
- 24 V DC Yes - 5V Yes
Current consumption - Output current, max. 210 mA
• Current consumption, max. 550 mA - Length of cable, max. 35 m; at max. 210 mA
■ Overview
• Extremely high-speed electronic cam controller
• Low-cost alternative to mechanical cam controllers
• 32 cam tracks, 16 onboard digital outputs for direct output of
actions
• Incremental or synchro-serial position decoding
Note:
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables for
counting and positioning functions.
5 Additional information is available in the Internet under:
http://www.siemens.com/simatic-technology
■ Technical specifications
6ES7 452-1AH00-0AE0 6ES7 452-1AH00-0AE0
Supply voltages Sensor supply
Rated value 5 V - sensor supply
- 24 V DC Yes - 5V Yes
Current consumption - Output current, max. 300 mA
• Current consumption, max. 500 mA - Length of cable, max. 32 m
Connection system 24 V - sensor supply
• Requisite front connector 1 x 48-pin - 24 V Yes
- Output current, max. 300 mA
Digital inputs
- Length of cable, max. 100 m
• Number of digital inputs 11
• Functions Reference point switches, Sensor
set actual value on-the-fly/ Connectable encoders
inprocess length measurement, - Incremental encoder Yes
brake enabling, enable (symmetrical)
track output Nos. 3-10
- Incremental encoder Yes
Input voltage (asymmetrical)
- Rated value, DC 24 V - Absolute encoder (SSI) Yes
- for signal "0" -28.8 to 5 V - 2-wire BEROS Yes
- for signal "1" 11 to 28.8 V Incremental encoder (symmetrical)
Input current - Track mark signals A, notA, B, notB
- for 0 signal, max (permissible 2 mA - Zero mark signal N, notN
closed-circuit current)
- Input signal 5 V differential signal
• For 2-wire BERO (phys. RS 422)
- For 1 signal, typical 9 mA - Input frequency, max. 1 MHz
Digital outputs Incremental encoder (asymmetrical)
• Number of digital outputs 16 - Track mark signals A, B
• Functions Cam tracks - Zero mark signal N
• Short-circuit protection Yes - Input voltage 24 V
of the output - Input frequency, max. 50 kHz; 50 kHz for 25 m cable
Output voltage length, 25 kHz for 100 m cable
length
- Rated value (DC) 24 V
- for 1 signal UP - 0.8 V Absolute encoder (SSI)
- Input signal 5 V differential signal (phys. RS 422)
Output current
- Data signal DATA, notDATA
- for 1 signal permissible range 600 mA; at Upmax
for 0 to 55 °C, max. - Clock signal CL, notCL
- for 0 signal residual current, max. 0.5 mA - Frame length 13 or 25 bits serial
- Clock frequency, max. 1 MHz
- Gray code yes
- Length of cable (shielded), max. 300 m; at max. 125 kHz
■ Overview
• Positioning module for serv o and/or stepper motors in
machines with high clock pulse rates
• Can be used for point-to-poi nt positioning tasks and for
complex traversing patterns
• Up to 3 independent motors can be controlled
Note:
SIMODRIVE Sensor/Motion Connect 500 feature position-
measuring systems and preassembled connecting cables for
counting and positioning functions.
■ Technical specifications
6ES7 453-3AH00-0AE0 6ES7 453-3AH00-0AE0
Voltages and currents Output current
Auxiliary voltage 1L+ to 4L+ - for 1 signal rated value 0.5 A; at 40°C, 0.1 A at 60°C
- Rated value (DC) 24 V - for 1 signal permissible range 5 mA
- dynamic range 18.5 to 30.2 V for 0 to 40 °C, min.
- static range 20.4 to 28.8 V - for 1 signal permissible range 0.6 A
for 0 to 40 °C, max.
Current consumption - for 1 signal permissible range 5 mA
• from load voltage 1L+, max 1 A; for 24 V displacement enco- for 40 to 60 °C, min.
der; 1 A for 5 V displacement - for 1 signal permissible range 0.12 A
encoder for 40 to 60 °C, max.
• from load voltage 2L+ up to 4L+, 2 A; per channel - for 0 signal residual current, max. 2 mA
max.
• from backplane bus 5 V DC, max. 1.6 A; rated current Switching frequency
• Power dissipation, max. 8W - at resistive load, max. 100 Hz
- at inductive load, max. 0.25 Hz
Connection system
• Requisite front connector 1 x 48-pin Sensor supply
5 V - sensor supply
Digital inputs
- 5V Yes
• Number of digital inputs 6; per channel/axis
- Output current, max. 300 mA
• Functions configurable
- Length of cable, max. 35 m; at max. 210 mA;
Input voltage 25 m at max. 300 mA
- Rated value, DC 24 V 24 V - sensor supply
- for signal "0" -3 to 5 V (max. 3 mA) - 24 V Yes
- for signal "1" 11 to 30 V (max. 7 mA) - Length of cable, max. 100 m; at max. 300 mA
Input delay (at rated value of the Sensor
input voltage)
Connectable encoders
• For standard inputs
- Incremental encoder Yes
- at 0 to 1, max. 15 µs; over input voltage range, 8 (symmetrical)
µs at 24 V DC
- Absolute encoder (SSI) Yes
- at 1 to 0, max. 45 µs; over input voltage range
Incremental encoder (symmetrical)
Digital outputs
- Input signal 5 V differential signal (phys. RS 422)
• Number of digital outputs 4; per channel/axis
- Input frequency, max. 1 MHz; for 10 m cable length;
• Functions configurable 0.5 MHz for 35 m cable length
• Short-circuit protection of the Yes
output Absolute encoder (SSI)
- Input signal 5 V differential signal (phys. RS 422)
Output voltage
- Clock frequency, max. 1.25 Mbit/s with 10 cable length
- Rated value (DC) 24 V (2.5 Mbit/s available soon)
- for 1 signal UP - 0.3 V - Length of cable (shielded), max. 250 m; at max. 156 kBit/s
■ Overview
• 16-channel closed-loop control module for universal closed-
loop control tasks
• Suitable for temperature, pressure, and flow control systems
• User-friendly online self-optim ization for temperature controls
• Preprogrammed controller structures
• 2 control algorithms
• 2 variants:
- FM 455 C as continuous-action controller
- FM 455 S as step controller or pulse controller
■ Technical specifications
6ES7 455- 6ES7 455- 6ES7 455- 6ES7 455-
0VS00-0AE0 1VS00-0AE0 0VS00-0AE0 1VS00-0AE0
Voltages and currents Output voltage
Load voltage L+ - for 1 signal L+ (-2.5 V)
- Rated value (DC) 24 V 24 V Output current
- permissible range, 20.4 V 20.4 V - for 1 signal rated value 0.1 A
lower limit (DC)
- for 1 signal permissible range 5 mA
- permissible range, 28.8 V 28.8 V for 0 to 60 °C, min.
upper limit (DC)
- for 1 signal permissible range 150 mA
Current consumption for 0 to 60 °C, max.
• from load voltage L+ (no load), 440 mA; 400 mA; - for 0 signal residual current, max. 0.5 mA
max. typ. 370 mA typ. 330 mA
Parallel switching of 2 outputs
• Power dissipation, max. 17.3 W 16.2 W
- for logical links Yes
• Power dissipation, typical 12 W 10.7 W
Switching frequency
Connection system
- at resistive load, max. 100 Hz
• Requisite front connector 2 x 48-pin 2 x 48-pin
- at inductive load, max. 0.5 Hz
Digital inputs - at lamp load, max. 100 Hz
• Number of digital inputs 16 16
Load impedance range
Length of cable - lower limit 240 Ω
- Length of cable shielded, max 1,000 m 1,000 m - upper limit 4 kΩ
- Length of cable unshielded, max 600 m 600 m
Analog inputs
• Input characteristic to comply Yes Yes
with IEC 1131, Type 2 • Number of analog inputs 16; 16 for 16; 16 for
thermocouples thermocouples
Input voltage or 2-conductor or 2-conductor
- Rated value, DC 24 V 24 V connection 8 for connection 8 for
Pt100 or Pt100 or
- for signal "0" -3 to 5 V -3 to 5 V 4-conductor 4-conductor
- for signal "1" 13 to 30 V 13 to 30 V connection connection
Input current • Length of cable shielded, max 200 m; 50m at 200 m; 50m at
80 mV and 80 mV and
- for 1 signal, typical 7 mA 7 mA
thermocouples thermocouples
Digital outputs • Permissible input voltage for the 20 V 20 V
• Number of digital outputs 32 voltage input (destruction limit),
• Length of cable shielded, max. 1,000 m max.
• Length of cable unshielded, max. 600 m • Permissible input voltage for the 40 mA 40 mA
current input (destruction limit), max.
• Short-circuit protection Yes; electronic
of the output Input ranges (rated values),
• Limitation of voltage induced L+ (-1.5 V) voltages
on circuit interruption to - 0 to +10 V Yes Yes
• Lamp load, max. 5W - -1.75 to +11.75 V Yes Yes
• Driving a digital input Yes - -80 mV to +80 mV Yes Yes
■ Overview
SIMATIC FM 458-1 DP integrated into SIMATIC S7-400
• Designed for high-performance and freely-configurable
control tasks in the SIMATIC S7-400
• Can be adapted as required to individual requirements, e.g.:
open-loop control, closed-loop control, computing and motion
control. Therefore highly flexible for many different applications.
• Extensive library with approx. 300 function blocks:
These include simple functions such as AND, ADD and OR up
to complex GMC (General Motion Control) blocks such as
virtual master or gearbox functions.
• User-friendly graphic configuring with the SIMATIC
engineering tool CFC (Continuous Function Chart):
5
Optimum code generation by compiler, therefore SCL is not
required.
• PROFIBUS DP interface onboard
SIMATIC FM 458-1 DP is based on more than 15 years
experience with high-performance control systems, and
combines this know-how with the advantages of SIMATIC – the
global leader in automation systems for decades already.
In contrast to other function modules with static structures/
functions, the FM 458-1 DP application module can be flexibly
configured according to individual requirements.
■ Overview
• Basic module for handling co mputing, open-loop control and
closed-loop control tasks
• PROFIBUS DP interface for linking of distributed I/O and drive
engineering
• Modular configuration with expansion modules for I/O and
communication
■ Technical specifications
6DD1 607-0AA1 6DD1 607-0AA1
Supply voltages Digital inputs
Rated value • Number of digital inputs 8; Connector X2
- 5 V DC Yes Input voltage
Current consumption - Rated value, DC 24 V
• Current consumption, max. 2.3 A - for signal "0" -1 to +6 V or input open
- Backup current, max. 10 µA - for signal "1" +13 to +33 V
Memory/backup Input current
Backup - for 0 signal, max (permissible 0 mA
- available Yes; Backup battery of the closed-circuit current)
SIMATIC power supply (3.4 V) - for 1 signal, typical 3 mA; at 24 V
Time Input delay (at rated value
Clock of the input voltage)
- Hardware clock Yes • For standard inputs
(realtime clock) - at 0 to 1, max. 20 µs
- Triggering 0.1 ms Status information/ interrupts/
PROFIBUS DP diagnostics
• Equidistance Yes; with connection Interrupts
to interrupt tasks - Interrupts Yes
• Direct data exchange Yes Potentials/ electrical isolation
(lateral communication)
Digital input functions
- Electrical isolation, No; via optional interface module
digital input functions only
Dimensions and weight
• Weight, approx. 0.8 kg
• Required slots 1
■ Overview
• Optional plug-in expansion module for the FM 458-1 DP basic
module
• For input and output of time-critical signals
• With digital and analog inputs/outputs
• Incremental and absolute valu e encoders can be connected
• 4 high-resolution analog outputs
• Fan-free operation up to 40°C
■ Technical specifications
6DD1 607-0CA1 6DD1 607-0CA1
Supply voltages Analog inputs
Rated value • Number of analog inputs 5; Differential inputs
- 5 V DC Yes Input ranges (rated values),
- 24 V DC Yes; to be applied from outside voltages
Current consumption - -10 V to +10 V Yes; -10 V +/- 4 LSB to
+10 V +/- 4 LSB
• Current consumption, typical 1.5 A (1 LSB = 4.88 mV)
Digital inputs - Input resistance 470 kΩ
• Number of digital inputs 16 (-10 V to +10 V)
Input voltage Analog outputs
- Rated value, DC 24 V • Number of analog outputs 8; 4 outputs 16 bits
4 outputs 12 bits
- for signal "0" -1 to +6 V or input open
• Voltage output, short-circuit Yes; to ground
- for signal "1" +13 to +33 V protection
Input current • Voltage output, short-circuit 16 bits: 27 mA
- for 0 signal, max (permissible 0 mA current, max 12 bits: 100 mA
closed-circuit current) Output ranges, voltage
- for 1 signal, typical 3 mA - -10 to +10 V Yes
Input delay (at rated value Analog value formation
of the input voltage)
Integration and conversion
• For standard inputs time/triggering per channel
- at 0 to 1, max. 200 µs
- with over-range (bits incl. sign), 4 AA: 16 bits
Digital outputs max 4 AA: 12 bits
• Number of digital outputs 8 5 AE: 12 bits
• Short-circuit protection Yes; electronic/thermal - Conversion time (per channel) 4 AA(16 bits): 2 µs
of the output 4 AA(12 bits): 4 µs
5 AE: 45 µs
• Short-circuit protection of the 250 mA
output, response threshold, Sensor supply
typical • Output voltage approx. 14 V (non-floating)
• Limitation of voltage induced Supply voltage + 1 V • Output current, rated value 100 mA
on circuit interruption to
• Short-circuit protection Yes; electronic
Output voltage
Sensor
- for 0 signal (DC), max. 3V
• Number of sensors that can be 12; 8 incremental encoders
- for 1 signal (DC), max. Supply voltage - 2.5 V connected, max. (synchronizable), 4 absolute
Output current value encoders
- for 1 signal rated value 50 mA Connectable encoders
- for 1 signal permissible range 100 mA - Incremental encoder Yes
for 0 to 40 °C, min. (symmetrical)
- for 0 signal residual current, max. 20 µA - Incremental encoder Yes
- Maximum switching current 80% at 50°C all outputs 50 mA (asymmetrical)
- Absolute encoder (SSI) Yes; Single or multiturn encoder
Output delay at resistive load with SSI (synchronous serial) or
- "0" to "1", max. 15 µs EnDat interface
■ Overview
• Optional plug-in expansion module for the FM 458-1 DP
basic module
• For fast communication via PROFIBUS DP or SIMOLINK
• EXM 448: with vacant slot for a MASTERDRIVES option
module
• EXM 448-1: with installed MA STERDRIVES option module SLB
for configuration of a SIMOLINK fiber-optic connection
■ Technical specifications
6DD1 607- 6DD1 607-
0EA0 0EA1
Supply voltages
Rated value
- 5 V DC Yes Yes
Current consumption
• Current consumption, typical 0.8 A 0.8 A
Dimensions and weight
• Weight, approx. 0.8 kg 0.8 kg
• Required slots 1 1
• For connecting the FM 458-1 DP to an SBxx or SU12 interface This cable is used to connect the SIMATIC TDC SM500
module peripheral (I/O) module or the SIMATIC S7-400 EXM 438-1
• To use the digital inputs of the FM 458-1 DP with interrupt expansion module to a SU13 interface module.
capability
This cable is used to connect the SIMATIC TDC SM500 The interface module is used to connect 8 digital inputs or
peripheral module (I/O) or the SIMATIC S7-400 EXM 438-1 outputs.
expansion module to up to 5 interface modules SB10, SB60,
SB70, SB61 SB71 and/ or SU12.
The interface module is used to connect 8 digital inputs with The interface module is used to connect 8 digital outputs with
conversion from 115/230 V DC/AC to 24 V DC conversion of the 24 V DC voltage on the module side to a max.
of 120 V DC/AC on the plant side using relays.
It is used to connect 8 digital inputs with conversion from The interface module is used to connect 8 digital outputs with
24/48 V DC to 24 V DC. conversion of the 24 V DC voltage on the module side to a max.
of 24/48 V DC/AC on the plant side using transistors.
The interface module is used to connect 10 signals; there is no This interface module can be used to connect 50 signals; there
electronic conversion. is no electronic conversion.
■ Technical specifications
SB 10 interface module SB70 interface module
Number of digital inputs or outputs 8 Number of digital outputs 8
Electrical isolation No • Output voltage, max 120 V DC/AC
Max. cable cross-section 1.5 mm2 Relay switching current
Dimensions (W x H x D) in mm 45 x 130 x 156 • For 120 V AC 2A
Weight 0.3 kg • For 120 V DC 0.2 A
Electrical isolation Using relay
Isolation voltage Separation assured:
SB60 interface module
• Isolation between inputs and
Number of digital inputs for 8 outputs assured
• Input voltage 115/230 V DC/AC • 1125 V AC test voltage for input
Electrical isolation Yes, via optocoupler current circuits
Insulation voltage Separation assured: Max. cable cross-section 1.5 mm2
• Isolation between inputs and Dimensions (W x H x D) in mm 45 x 130 x 156
outputs assured Weight 0.32 kg
• 1125 V AC test voltage for input
current circuit
Max. cable cross-section 1.5 mm2 SB71 interface module
Dimensions (W x H x D) in mm 45 x 130 x 156 Number of digital outputs 8
Weight 0.31 kg • Output voltage, max 24/48 V DC
Output current, max. 40 mA, short-circuit proof
Electrical isolation Yes, via optocoupler
SB61 interface module
Max. cable cross-section 1.5 mm2
Number of digital inputs for 8
Dimensions (W x H x D) in mm 45 x 130 x 156
• Input voltage 24/48 V DC
Weight 0.32 kg
Electrical isolation Yes, via optocoupler
Max. cable cross-section 1.5 mm2
Dimensions (W x H x D) in mm 45 x 130 x 156
Weight 0.32 kg
5 French
Italian
6ES5 242-5AB31
6ES5 242-5AB51
Terminal connector 6ES5 983-2AB11
4 units
Converter 6ES5 242-1AU11
for 24 V asymmetric incremental
encoders to 5 V (RS 422)
symmetric incremental encoders
705 connecting cable 6ES5 705-2CC00
for Siemens position encoders
(RS 422)
A) Subject to export regulations: AL: N and ECCN: EAR99H
■ Overview
• For high-performance transmissi on of messages via point-to-
point connections (high message rate)
• Physical interface: RS 422/RS 485 (X.27)
• Up to 32 nodes
• Protocol implemented: ASCII, 3964 (R)
• Simple parameterization via a parameterization tool integrated
into STEP 7
■ Technical specifications
6ES7 440-1CS00-0YE0 6ES7 440-1CS00-0YE0
Supply voltages Interfaces
Rated value • Number 1
- 5 V DC Yes • Physical interface, Yes
- 24 V DC Yes RS422/RS485 (X.27)
• RS 422/485, length of cable 1,200 m
Current consumption (shielded), max.
• from backplane bus 5 V DC, max. 360 mA Point-to-point
• Power dissipation, typical 1.7 W Integral protocol driver
Memory/backup - 3964 (R) Yes
Memory - ASCII Yes
- Memory requirement per 1 to 5 kBytes for parameters, Transmission rate, RS 422/485
interface in the S7 CPU 0 to 55 kBytes for message - with 3964 (R) protocol, max. 115.2 kBit/s
memory card texts
- with ASCII protocol, max. 115.2 kBit/s
Communication functions
CPU/ programming
• S7 extended communication Yes
Configuration software
Number of connections - STEP 7 Yes; separate parameterization
- overall 31 masks
Dimensions and weight
• Weight, approx. 720 g
• Width 25 mm
• Height 290 mm
• Depth 210 mm
■ Overview
• For powerful, high-speed serial communication via point-to-
point connections
• 2 versions:
- CP 441-1 with 1 variable interface for simple point-to-point
connection
- CP 441-2 with 2 variable interfaces for powerful point-to-
point connection
• Plug-in interface modules for different transmission interfaces:
RS 232C (V.24) , 20 mA (TTY) or RS 422/RS 485 (X.27)
• Implemented protocols: ASCII, 3964 (R), printer drivers;
CP 441-2 additionally has RK 512 and customized protocols
(retrofittable) 5
• Simple parameterization via a parameterization tool integrated
into STEP 7
■ Technical specifications
6ES7 441- 6ES7 441- 6ES7 441- 6ES7 441-
1AA03-0AE0 2AA03-0AE0 1AA03-0AE0 2AA03-0AE0
Supply voltages Point-to-point
Rated value • Supported printers HP-Deskjet, HP-Deskjet,
- 5 V DC Yes HP-Laserjet, HP-Laserjet,
IBM-Proprinter, IBM-Proprinter,
- 24 V DC Yes user-defined user-defined
Current consumption • Transmission rate, max. 38.4 kBit/s 115.2 kBit/s;
• from backplane bus 5 V DC, max. 700 mA; with- 700 mA; with- split between
out interface out interface both interfaces
module module
Integral protocol driver
Memory/backup - 3964 (R) Yes Yes
Memory - ASCII Yes Yes
- Memory requirement per inter- 1 to 5 kBytes 1 to 5 kBytes - Printer Yes Yes
face in the S7 CPU for parameters, for parameters,
memory card 0 to 55 kBytes 0 to 55 kBytes - Customer-specific drivers Yes
for message for message for later loading
texts texts, - RK512 Yes
0 to 64 kBytes
for loadable Transmission rate, 20 mA (TTY)
drivers - with 3964 (R) protocol, max. 19.2 kBit/s 19.2 kBit/s
Communication functions - with ASCII protocol, max. 19.2 kBit/s 19.2 kBit/s
• S7 extended communication Yes Yes - with printer driver, max. 19.2 kBit/s 19.2 kBit/s
- with RK 512 protocol, max. 19.2 kBit/s
Number of connections
- overall 8 8 Transmission rate, RS 422/485
- with 3964 (R) protocol, max. 38.4 kBit/s 115.2 kBit/s
Interfaces
- with ASCII protocol, max. 38.4 kBit/s 115.2 kBit/s
• Number 1; variable 2; variable
- with printer driver, max. 38.4 kBit/s 115.2 kBit/s
• Physical interface, 20mA (TTY) Yes Yes
- with RK 512 protocol, max. 115.2 kBit/s
• Physical interface, RS 232C (V.24) Yes Yes
• Physical interface, RS422/RS485 Yes Yes Transmission rate, RS232
(X.27) - with 3964 (R) protocol, max. 38.4 kBit/s 115.2 kBit/s
• 20mA (TTY), length of cable 1,000 m 1,000 m - with ASCII protocol, max. 38.4 kBit/s 115.2 kBit/s
(shielded), max. - with printer driver, max. 38.4 kBit/s 115.2 kBit/s
• RS 232, length of cable (shielded), 10 m 10 m - with RK 512 protocol, max. 115.2 kBit/s
max.
• RS 422/485, length of cable 1,200 m 1,200 m CPU/ programming
(shielded), max. Configuration software
Interface modules - STEP 7 Yes; separate Yes; separate
parameteriza- parameteriza-
- 20 mA (TTY), current 300 mA at 5 V, 300 mA at 5 V, tion masks tion masks
consumption from 5 V/24 V, max. 45 mA at 24 V 45 mA at 24 V
- RS 422/485 (X.27), current 300 mA 300 mA
consumption from 5 V, max.
- RS232C (V.24), current 300 mA 300 mA
consumption from 5 V, max.
5
■ Ordering data Order No. Order No.
CP 441-1 communications 6ES7 441-1AA03-0AE0 RS 422/485 connecting cable
processor
5m 6ES7 902-3AB00-0AA0
with one variable interface for
interface submodules; 10 m 6ES7 902-3AC00-0AA0
incl. configuring package on CD 50 m 6ES7 902-3AG00-0AA0
CP 441-2 communications 6ES7 441-2AA03-0AE0 CP 441-1, CP 441-2 manual
processor
with two variable interfaces for German 6ES7 441-2AA00-8AA0
interface submodules; English 6ES7 441-2AA00-8BA0
incl. configuring package on CD
French 6ES7 441-2AA00-8CA0
Interface modules
Italian 6ES7 441-2AA00-8EA0
RS 232C (V.24) 6ES7 963-1AA00-0AA0
Loadable drivers for CP 441-2
20 mA (TTY) 6ES7 963-2AA00-0AA0
MODBUS Master (RTU format)
RS 422/485 (X.27) 6ES7 963-3AA00-0AA0
• Single license 6ES7 870-1AA01-0YA0
RS 232 connecting cable
• Single license, without software 6ES7 870-1AA01-0YA1
5m 6ES7 902-1AB00-0AA0 or documentation
10 m 6ES7 902-1AC00-0AA0 MODBUS Slave (RTU format)
TTY connecting cable • Single license 6ES7 870-1AB01-0YA0
5m 6ES7 902-2AB00-0AA0 • Single license, without software 6ES7 870-1AB01-0YA1
10 m 6ES7 902-2AC00-0AA0 or documentation
50 m 6ES7 902-2AG00-0AA0 Data Highway (DF1 protocol)
• Single license 6ES7 870-1AE00-0YA0
• Single license, without software 6ES7 870-1AE00-0YA1
or documentation
■ Overview
• Master connection of the S7-400 to PROFIBUS
• Communication services:
- PG/OP communication
- S7 communication
- S5-compatible communication (SEND/RECEIVE)
- PROFIBUS FMS
• Time-of-day synchronization
• Simple configuration and programming using PROFIBUS
• PG communication between networks through S7 routing
• Easy to integrate into the SIMATIC S7-400 system
• Module changeover without PG 5
• Operation in the SIMATIC H system for redundant S7
communication
■ Technical specifications
Data transmission rate 9.6 kbit/s to 12 Mbit/s Performance data for
S5-compatible communication
Interface (SEND/RECEIVE)
• Connection to PROFIBUS 9-pin Sub-D socket (RS 485) • Number of connections that can Max. 32
Power supply 5 V DC ± 5% be used
Current input from 5 V DC 1.2 A • Useful data / connection max. 240 bytes
(SEND and RECEIVE)
Power loss 6.5 W
Performance data for
Perm. ambient conditions FMS function
• Operating temperature 0 °C to +60 °C • Number of connections that can Max. 48
• Transport/storage temperature -40 °C to +70 °C be used
• Relative humidity Max. 95% at +25°C • Variable length READ Max. 237 bytes
Construction • Variable length WRITE Max. 233 bytes
• Dimensions (WxHxD) in mm 25 x 290 x 210 • Configurable server variables 512
• Weight Approx. 700 g • Variables that can be loaded from 2640
partners
Performance data for
S7 communication Multi-protocol operation
• Number of connections that can 16 to 481) • Number of connections that can Max. 59
be used used (2 of which are reserved
for PG/OP communication)
1) Dependent on CPU type
■ Overview
• DP V1 master connection of S7-400 to PROFIBUS
• For configuring additional PROFIBUS DP lines
• Communication services:
- PROFIBUS DP
- PG/OP communication
- S7 communication
- S5-compatible communication (SEND/RECEIVE)
• Time-of-day synchronization
• Simple configuration and programming using PROFIBUS
• PG communication between networks through S7 routing
• Easy to integrate into the SIMATIC S7-400 system 5
• Module replacement without the need for a programming
device.
• Operation in the SIMATIC H system for redundant S7
communication or DP master communication
• Data record routing (PROFIBUS DP)
• Add or change distributed I/O during normal operation
■ Technical specifications
Data transmission rate 9.6 kbit/s to 12 Mbit/s Performance data for DP master
function
Interfaces
• DP master DP-V1
• Ports 9-pin Sub-D socket (RS 485)
• Number of operable DP slaves Max. 125
Power supply 5 V DC ± 5%
24 V DC ±5% • Size of DP data areas overall
- DP input area Max. 4 KB
Current input from 5 V DC 1.3 A
- DP output range Max. 4 KB
Power loss 6.5 W
• Size of DP data areas per
Perm. ambient conditions connected DP slave
• Operating temperature 0 °C to +60 °C - DP input area Max. 244 bytes
• Transport/storage temperature -40 °C to +70 °C - DP output range Max. 244 bytes
• Relative humidity Max. 95% at +25°C Performance data
Construction for S7 communication
• Dimensions (WxHxD) in mm 25 x 290 x 210 • Number of connections that can 16 to 481)
be used
• Weight Approx. 700 g
Performance data
Number of external DP-lines in one 10 for S5-compatible communication
central rack (SEND/RECEIVE)
• Number of connections that can Max. 32
be used
• Useful data / connection max. 240 bytes
(SEND and RECEIVE)
Multi-protocol operation
• Number of connections that can
used (2 of which are reserved
for PG/OP communication)
- Without DP Max. 59
- With DP Max. 55
1) Dependent on CPU type
■ Overview
• Connection of SIMATIC S7-400 to Industrial Ethernet
- 10/100 Mbit/s full/half duplex connection with autosensing
for automatic switchover between AUI, ITP and RJ45 inter-
face
- Universal connection options for ITP, RJ45 and AUI
- Multi-protocol operation with ISO, TCP/IP and UDP transport
protocol
- Adjustable Keep Alive function
• Communication services:
- ISO, TCP/IP and UDP transport protocols
- PG/OP communication
- S7 communication
- S5-compatible communication
5
• Multicast for UPD
• Cross-network programming device/operator panel
communication through S7 routing
• Remote programming and init ial startup via the network
• Access protection by means of configurable access list
■ Technical specifications
Data transmission rate 10/100 Mbit/s autosensing Performance data
Interfaces S5-compatible communication
• Connection to Industrial Ethernet 15-pin Sub-D connector (SEND/RECEIVE)
- AUI (10 Mbit/s) • Sum of all simultaneously operable Max. 64
ISO/TCP/UDP connections
- ITP (10/100 Mbit/s)
• Number of useful data ISO or Max. 8 Kbytes
• 10BaseT, 100BaseTX RJ45 TCP/IP
Current consumption • Number of useful data UDP Max. 2 Kbytes
• From +5 V DC ( ± 5%) Approx. 1.4 A S7 communication
• From 24 V DC ( ± 5%) Typ. 220 mA, • Number of connections 1) Max. 48
Max. 350 mA (depending on the
interface used) Multi-protocol operation
Power loss 8.6 W • Sum of all simultaneously Max. 64
operable connections
Perm. environmental conditions
• Operating temperature 0°C to +60°C
• Transport/storage temperature -40 °C to +70 °C
• Relative humidity Max. 95% at +25 °C
Design
• Module format Compact module S7-400,
single width
• Dimensions (W x H x D) in mm 25 x 290 x 210
• Weight Approx. 700 g
Configuration software NCM S7 for Industrial Ethernet
(included in the scope of
supply of STEP 7 V5.x)
1) Use depends on performance of used S7-CPU/FM
■ Overview
• Connection of SIMATIC S7-4 00 to Industrial Ethernet
- 10/100 Mbit/s full/half duplex connection with autosensing
- Connection via RJ45
- Multi-protocol operation for ISO, TCP/IP and UDP
- Adjustable Keep Alive function
• Communication services:
- PROFINET IO Controller
- PROFINET CBA
- ISO, TCP/IP and UDP transport protocols:
Multicast for UDP
- Programming device/operator panel communication:
Cross-network by means of S7 routing
- S7 communication
5
- S5-compatible communication
- IT communication:
HTTP communication supports access to process data
through Web browsers;
FTP communication supports program-controlled FTP client
communication,
Access to data blocks through FTP server,
Data handling for own file system through FTP, E-mail
• IP address assignment via DHCP, simple PC tool or via the
user program (e.g. HMI)
• Access protection by means of configurable access list
• Single-width module with integrated 4-port switch saves space
in the rack and control cabinet. Thanks to the integrated
autocrossing function, the CP 443-1 Advanced is very well
suited for establishing small local networks.
• Module replacement without programming device; all
information is stored on the C-PLUG (also file system for
IT functions).
• Extensive diagnostic function s for all modules in the rack
• Integration into network ma nagement systems through the
support of SNMP V1 MIB-II
■ Technical specifications
Data transmission rate 10/100 Mbit/s autosensing Performance data
Interfaces Memory capacity
• 10BaseT, 100BaseTX 4x RJ45 • Flash memory file system 32 MB, approx. 30 MB of which
is freely available to the user
Power supply DC +5 V (+/- 5%) from the back-
plane bus • RAM 32 MB, approx. 30 MB of which
is freely available to the user;
Current consumption additional 512 KB buffered via
• From backplane bus Max. 1.8 A central backup battery
Power loss 7.25 W PG/OP communication
• Number of PG connections Max. 2
Perm. ambient conditions
• Number of OP connections Max. 30
• Operating temperature 0 ×C to +60 ×C
S7 communication
• Transport/storage temperature -40 ×C to +70 ×C
• Number of connections Max. 128
• Relative humidity Max. 95% at +25 ×C
S5-compatible communication
Construction (SEND/RECEIVE)
• Module format Compact module S7-400, single • Sum of all simultaneously operable Max. 64
width TCP/UDP connections
25 x 290 x 217 • Useful data
• Dimensions (W x H x D) in mm
-ISO or TCP/IP Max. 8 KB
• Weight Approx. 750 g
-UDP Max. 2 KB
Configuring software STEP7 V5.3 + SP11)2) -E-mail Max. 2 KB
PROFINET communication See http://www.siemens.com/
profinet/ik-info
HTTP communication
• Number of server connections Max. 4
Multi-protocol operation
• Sum of all simultaneously operable Max. 128
connections
1) For configuring PROFINET IO 2) For configuring PROFINET CBA, iMap V2.0 is also required
■ Overview
• The connection for the SIMATIC S7-400 to Industrial Ethernet
- 10/100 Mbit/s full/half duplex connection with autosensing
for automatic switchover between AUI, ITP and RJ45 inter-
face
- universal connection options for ITP, RJ45 and AUI
- Multi-protocol operation for ISO, TCP/IP and UDP
- Adjustable Keep Alive function
• Communication services:
- Programming device/operator panel communication
- S7 communication
- S5-compatible communication
- IT communication
• Web-function for access to process data via Web browser
5
• E-mail function for sending electronic messages via the
S7-400.
• FTP communication permits pr ogram-controlled FTP client
communication,
access to data blocks via FTP server
• Multicast for UPD
• Cross-network programming device/operator panel
communication through S7 routing
• Remote programming and init ial startup via the network
■ Technical specifications
Data transmission rate 10/100 Mbit/s autosensing Performance data
Interfaces IT communication
• Connection to Industrial 15-pin Sub-D socket Number of connections to an e-mail Max. 1
Ethernet server
- AUI (10 Mbit/s) FTP communication
- ITP (10/100 Mbit/s) Number of client connections Max. 10
• 10BaseT, 100BaseTX RJ45
Number of server connections Max. 2
Current consumption
Capacity of flash memory file sys- 10 MB
• from DC + 5V ( ±5%) approx. 1.5 A tem
• from DC +24V ( ±5%) typ. 220 mA Service life of the Flash Memory 10,000 write cycles
max. 340 mA cells
Power loss 9.1 W S5-compatible communication
Perm. ambient conditions (SEND/RECEIVE)
• Operating temperature 0 °C to +60 °C • Sum of all simultaneously operable Max. 64
ISO/TCP/UDP connections
• Transport/storage temperature -40 °C to +70 °C
• Useful data
• Relative humidity Max. 95% at +25 °C
- ISO or TCP/IP Max. 8 KB
Construction
- UDP Max. 2 Kbyte
• Module format Compact module S7-400, single
width - E-mail Max. 2 Kbyte
• Dimensions (WxHxD) in mm 25 x 290 x 210 S7 and programmable device/
operator panel communication
• Weight Approx. 700 g
• Number of connections 1) Max. 48
Configuring software NCM S7 for Industrial Ethernet V5
or higher (included in the scope Multi-protocol operation
of delivery of STEP 7 V5.x). • Sum of all simultaneously operable Max. 64
connections
1) Use depends on performance of S7-CPU/FM used.
■ Overview
• The link to Industrial Ethernet in conjunction with MMS
services as per MAP 3.0
• To off-load the CPU from communication tasks and
to implement additional links
• MMS services:
- Environment Management
- VMD Support Services
- Variable Access Services
■ Technical specifications
6ES7 444-1MX00-0XE0 6ES7 444-1MX00-0XE0
Current consumption Environmental requirements
• from backplane bus 5 V DC, max. 3.1 A Operating temperature
• Power dissipation, typical 15.6 W - min. 0 °C
Communication functions - max. 40 °C
- Forced ventilation 55 °C
• Bus protocol/transfer protocol MAP 3.0 based on the transport
protocol according to ISO 8073 Storage/transportation temperature
class 4 - min. -20 °C
• S7 extended communication Yes - max. 60 °C
Number of connections Relative humidity
- overall 1 - Operation, min. 8%
Connection system - Operation, max. 80 %; at 25 ºC (no condensation)
• Bus lines 15-pin sub-D female connector Vibration
(automatic switchover between
- Operation, tested Yes; 10 to 58 Hz: 0.0035 mm,
AUI and Industrial Twisted Pair)
to IEC 60068-2-6 const. amplitude, 58 to 500 Hz:
Industrial Ethernet 0.5 g, const. acceleration
• Transmission rate, max. 10 Mbit/s Dimensions and weight
• Weight, approx. 2,080 g
• Width 50 mm
• Height 290 mm
• Depth 210 mm
■ Overview
• Transceiver for the transition from a redundant
PROFIBUS DP master system to a single-channel
PROFIBUS DP master system
• To connect devices with a sing le PROFIBUS DP interface to
the redundant PROFIBUS DP master system of the SIMATIC
S7-400H
■ Technical specifications
6ES7 197-1LA02-0XA0 6ES7 197-1LA02-0XA0
System PROFIBUS DP
Requirements of a • Transmission rate, max. 12 Mbit/s;
DP master system 9.6 / 19.2 / 45.45 / 93.75 / 187.5 /
500 kbit/s
- Length diagnostics frame 231 Byte 1.5 / 3 / 6 / 12 Mbit/s
- Length configuration frame 244 Byte Dimensions and weight
- Length user data frame 244 Byte • Weight, approx. 350 g
- Length parameterization frame 214 Byte • Width 40 mm
Protocols • Height 125 mm
• PROFIBUS DP protocol Yes • Depth 130 mm
■ Overview
• For connecting the ET 200M as a slave to the optical
PROFIBUS
• Optical expansion to IM 153-2 (High Feature) (RS 485)
• Integral fiber-optic interfac e for plastic and PCF cables
• Redundancy capability
• With time stamping functionality and time synchronization
■ Technical specifications
IM 153-2 FO interface module IM 153-2 FO interface module (continued)
Data transmission rate 9.6 kbit/s to 12 Mbit/s Output voltage 5 V DC
(not 3 and 6 Mbit/s)
Output current (at 5 V DC), max. 1 A (for backplane bus)
Transmission technology FOC; Wavelength λ = 660 nm
Configuring software STEP 7/ COM PROFIBUS/third-
Internode communication support Yes, transmitter party tools using GSD file
(from 6ES7 153-2AB01-0XB0)
Degree of protection IP20
Interfaces
• Connection to optical 2 x duplex sockets Ambient temperature 0°C to +60 °C
PROFIBUS Operating altitude, max. 3000 m above mean sea level
Supply voltage 24 V DC through screw terminals Dimensions (W x H x D) in mm 40 x 125 x 120
• Permissible range (including 20.4 to 28.8 V
ripple) Weight, approx. 350 g
• Current consumption at 24 V DC, 625 mA
typical
■ Overview
• For simple and user-friendl y connection of sensors and
actuators
• For retaining the wiring when replacing modules
• With coding to avoid mistakes when replacing modules
■ Benefits
• Simple plug connections for front connector module, cable
and terminal block
• Fast, low-cost wiring
• Power supply for digital and analog modules can be
connected to the front connector module or terminal block
• Reduction in wiring errors, clear control cabinet wiring
• Byte-oriented signal distribution with digital modules
• Each component can be replaced individually
• Any cable length can be configured without waste
5
■ Technical specifications
Technical specifications for front connector module Terminal blocks with relay 8S
Rated operating voltage 24 V DC Field circuit side
Max. permitted operating voltage 60 V DC Coil operating voltage 24 V DC
Max. permitted continuous current Input connections None
• per connector pin 1A Contact side
Max. permitted summation current 4 A/byte (voltage infeed) Number of relay outputs 8 (NO contacts)
Permissible ambient air temperature 0 °C to + 60 °C Contact design Single contact, 1 NO
Test voltage 0.5 kV, 50 Hz, 60 s Switching capacity (resistive load) Max. 2 A/250 V AC,
Air and creepage distances IEC 664 (1980), IEC 664 A (1981), max. 2 A/30 V DC
in accordance with max. 0.2 A/60 V DC
DIN VDE 0110 (01.89), Recommended minimum load ≥
overvoltage class II, 100 mA
pollution degree 2 Switching frequency 6 cycles/minute
Service life
• Mechanical 10 x 106 switching operations
Terminal blocks for 1-wire connection and 3-wire initiators
• Electrical 600 x 103 switching operations at
Max. operating voltage 60 V DC 230 V AC/2 A/ power factor = 1
Continuous current per signal 1A Operating temperature 0 °C to +60 °C
Max. summation current 4 A/byte Mounting position Horizontal, ventilation slots
(voltage input) upwards and downwards.
Operating temperature 0 °C to + 60 °C To permit heat dissipation, a
space of at least 30 mm must be
Mounting position Any left above and below the relay ter-
minal block
Air and creepage distances IEC Report 664, IEC 664 A,
IEC 1131 T2, Air and creepage distances IEC 1131-2 (1992), EN 50 178
CSA C22.2 No 142 UL 508, (4/98) overvoltage category III,
VDE 0160 (12.90), pollution severity 2 between trig-
overvoltage category II, ger circuit and relay contacts:
pollution severity 3 5.5 mm between contact groups
K0-K3 and K4-K7: 5.5 mm within
Dimensions (W x H x D) in mm a contact group: 3.2 mm
• 1-wire connection Approx. 51 x 41 x 55 UL and CSA available soon
6ES7924-0AA00-_A_0
Terminal blocks can be removed for
• For 3-wire initiators Approx. 60 x 41 x 70 independent wiring
6ES7924-0CA00-_A_0
• For 24 V power supply for digital 4-pole terminal block
modules
• For relay outputs Two 8-pole terminal blocks
Dimensions (W x H x D) in mm Approx. 60 x 68 x 78
6ES7924-0CD00-_A_0
Dimensions (W x H x D) in mm
pollution severity 3
Approx. 60 x 41 x 70
Dimensions (W x H x D) in mm
6ES7924-0CC00-_A_0
Approx. 60 x 41 x 70 5
6ES7924-0BB00-_A_0
■ Overview
The flexible connection permits a fast and direct connection
between the input/output modules of the SIMATIC S7-400 and
the individual elements in the switchgear cabinet.
Single cores already attached reduce wiring overheads.
Core cross-sections of 0.5 mm2 also permit higher currents.
• Individual cores can be routed directly to each element in the
control cabinet
• Higher currents are possible usin g a larger cross-section, with
a smaller voltage drop
■ Technical specifications
Front connector with single cores Front connector with single cores
Rated operating voltage DC 24 V Cross-section 0.5 mm2, Cu
Max. permissible continuous 1.0 A Bundle diameter in mm approx. 17
current if all cores carry load Color of core blue, RAL 5010
simultaneously
Designation of the cores numbered consecutively
Permissible ambient air 0 to +60 °C from 3 to 48 (adapter contact =
temperature core number)
Number of cores 46 Design Screw-type terminal or
crimp contact
Core type H05V-K-single cores or
UL-Style 1007/1569
CSA-AWM TR64
■ Overview
• Also suitable for S7-400H
CR2 (Central Rack)
• For configuring central controllers
• For up to 18 modules
• Segmented racks:
For operating two independent S7-400 CPUs without S7-400
multicomputing, but with communication between the CPUs
via the backplane bus (C-bus). Both CPUs can address local,
separate I/O modules (segmented P-bus).
CR3 (Central Rack)
• For configuring central controllers
5
• Optimized for distributed automa tion tasks as it can support
up to 4 modules
UR2-H
• For setting up a complete S7-400H system in a single mounting
rack
• The basic mechanical framew ork of the SIMATIC S7-400/S7-
• Also suitable for S7-400:
400H
Operation of 2 separate CPUs with their own I/O
• For accommodating the modules, supplying them with opera- (own P-bus and K-bus)
ting voltage and connecting them via the backplane bus
• Can also be used as an expansion rack
• Several versions for configurin g central controllers and expan-
• For up to 18 modules
sion racks
ER1 (Expansion Rack)
UR1 (Universal Rack)
• For cost-effective configuration of expansion racks
• For configuring central cont rollers and expansion racks
• For up to 18 modules with restricted functionality
• For up to 18 modules
• Also suitable for S7-400H
• Also suitable for S7-400H
ER2 (Expansion Rack)
UR2 (Universal Rack)
• For cost-effective configuration of expansion racks
• For configuring central cont rollers and expansion racks
• For up to 9 modules with restricted functionality
• For up to 9 modules
• Also suitable for S7-400H
■ Technical specifications
6ES7 400-1TA01-0AA0 6ES7 400-1JA01-0AA0 6ES7 401-2TA01-0AA0 6ES7 401-1DA01-0AA0
Configuration
• Number of single-width slots, 18 9 18; 2 segments with 4
max. 8 and 10 slots
Racks
- K bus Yes Yes Yes Yes
- P bus Yes Yes Yes Yes
Dimensions and weight
• Weight, approx. 3,000 g 1,500 g 3,000 g 1,500 g
• Width 482.5 mm 257.5 mm 482.5 mm 130 mm
• Height 290 mm 290 mm 290 mm 290 mm
• Depth 27.5 mm 27.5 mm 27.5 mm 27.5 mm
■ Overview
• Fans for the SIMATIC S7-400
• Necessary when using modules that generate an extremely
large amount of heat
■ Technical specifications
6ES7 408- 6ES7 408- 6ES7 408- 6ES7 408-
1TA01-0XA0 1TB00-0XA0 1TA01-0XA0 1TB00-0XA0
Supply voltages Current consumption
Rated value • Inrush current, typ. 0.9 A; at 24 V 0.6 A at rated
voltage
- 24 V DC Yes 230 V AC,
- permissible range, 19.2 V 1.15 A at rated
lower limit (DC) voltage
- permissible range, 30 V 120 V AC
upper limit (DC) • Power dissipation, max. 11 W 20 W
- 120 V AC Yes Relay outputs
- 230 V AC Yes • Rated supply voltage 24 V 24 V
- permissible range, 85 or170 V AC of the relay L+ (DC)
lower limit (AC)
Switching capacity of the contacts
- permissible range, 132 V AC or
upper limit (AC) 264 V AC - at resistive load, max. 200 mA 200 mA
- permissible frequency range, 47 Hz Dimensions and weight
lower limit • Weight, approx. 1.6 kg 2 kg
- permissible frequency range, 63 Hz • Width 482.5 mm 482.5 mm
upper limit
• Height 109.5 mm 109.5 mm
• Depth 235 mm 235 mm
■ Overview
• SIMATIC S5 expansion racks for distributed expansion of the The following components can be connected to the
SIMATIC S7-400 SIMATIC S7-400:
• For connection to ex isting SIMATIC S5 systems • Expansion racks ER 701-2 and ER 701-3 from the
SIMATIC S5-115U series
• Expansion racks EG 183U and EG 185U from the
SIMATIC S5-135U/-155U series
Suitable SIMATIC S5 modules
Expansion rack ER 701-2, EG 183U, Expansion rack ER 701-2, EG 183U,
ER 701-3 EG 185 U ER 701-3 EG 185 U
■ Overview
• Send interface for central expansion up to 5 m
• Transmission of P and K bus
• Can be plugged into central controller
• Up to 8 expansion racks can be connected
• Can be used exclusively with IM 461-0
■ Technical specifications
6ES7 460-0AA01-0AB0 6ES7 460-0AA01-0AB0
Current consumption Dimensions and weight
• from backplane bus 5 V DC, max. 140 mA • Weight, approx. 600 g
• Power dissipation, max. 700 mW • Width 25 mm
Configuration • Height 290 mm
• Length of cable between two 5m • Depth 217 mm
adjacent interface modules, max.
■ Overview
• Receive interface for centra lized expansion up to 5 m
• Transmission of P and K bus
• Can be plugged into expansion rack
• To be used exclusively with IM 460-0
■ Technical specifications
6ES7 461-0AA01-0AA0 6ES7 461-0AA01-0AA0
Current consumption Dimensions and weight
• from backplane bus 5 V DC, max. 290 mA • Weight, approx. 610 g
• Power dissipation, max. 1,450 mW • Width 25 mm
Configuration • Height 290 mm
• Length of cable between two 5m • Depth 217 mm
adjacent interface modules, max.
■ Overview
• Send interface for central expansion up to 1.5 m
• Transmission of P bus
• With voltage supply for expansion racks
• Can be plugged into central controller
• Up to 2 expansion racks can be connected
• Can be used exclusively with IM 461-1
■ Technical specifications
6ES7 460-1BA01-0AB0 6ES7 460-1BA01-0AB0
Current consumption Dimensions and weight
• from backplane bus 5 V DC, max. 85 mA • Weight, approx. 600 g
• Power dissipation, max. 425 mW • Width 25 mm
• Height 290 mm
Configuration
• Depth 217 mm
• Length of cable between two 1.5 m
adjacent interface modules,
max.
■ Overview
• Receive interface for cent ral expansion up to 1.5 m
• Transmission of P bus
• With voltage supply for expansion racks
• Can be plugged into expansion rack
• Can be used exclusively with IM 460-1
■ Technical specifications
6ES7 461-1BA01-0AA0 6ES7 461-1BA01-0AA0
Current consumption Dimensions and weight
• from backplane bus 5 V DC, max. 120 mA • Weight, approx. 610 g
• Power dissipation, max. 600 mW • Width 25 mm
Configuration • Height 290 mm
• Length of cable between two 1.5 m • Depth 217 mm
adjacent interface modules,
max.
■ Overview
• Send interface for distribu ted expansion up to 102 m
• Transmission of K and P bus
• Can be plugged into central controller
• Up to 8 expansion racks can be connected
• To be used exclusively with IM 461-3
■ Technical specifications
6ES7 460-3AA01-0AB0 6ES7 460-3AA01-0AB0
Current consumption Dimensions and weight
• from backplane bus 5 V DC, max. 1,550 mA • Weight, approx. 630 g
• Power dissipation, max. 7,750 mW • Width 25 mm
Configuration • Height 290 mm
• Length of cable between two 102 m
• Depth 217 mm
adjacent interface modules,
max.
■ Overview
• Receive interface for distributed expansion up to 102 m
• Transmission of data from the P-bus and C-bus
• Can be plugged into expansion rack
• To be used exclusively with IM 460-3
■ Technical specifications
6ES7 461-3AA01-0AA0 6ES7 461-3AA01-0AA0
Current consumption Dimensions and weight
• from backplane bus 5 V DC, max. 620 mA • Weight, approx. 620 g
• Power dissipation, max. 3,100 mW • Width 25 mm
Configuration • Height 290 mm
• Length of cable between two 102 m • Depth 217 mm
adjacent interface modules,
max.
■ Overview
• Send IM for distributed expansion with SIMATIC S5 expansion
rack up to 600 m
• Can be plugged into central controller
• Up to 8 SIMATIC S5 expansion racks can be connected
• Can be used exclusively with IM 314
■ Technical specifications
6ES7 463-2AA00-0AA0 6ES7 463-2AA00-0AA0
Current consumption Dimensions and weight
• from backplane bus 5 V DC, max. 1,320 mA • Weight, approx. 360 g
• Power dissipation, max. 6,600 mW • Width 25 mm
Configuration • Height 290 mm
• Length of cable between first and 600 m • Depth 217 mm
the last interface module, max.
■ Overview
• For connection of the S7-400 as a master to PROFIBUS DP
• For setting up further PROFIBUS DP lines
• PROFIBUS DP communication services and PG/OP communi-
cation
• Simple programming and configuring via PROFIBUS
• Interfaces: RS 485 (IM 467) or integrated FO interface
(IM 467 FO)
Designed for Industry
• Subprocess-oriented configuratio n of an automation solution
5 through the use of several IMs
• Allows up to 14 additional DP bus lines to be connected to the
S7-400
• Integrated fiber-optic interface
■ Technical specifications
6ES7 467- 6ES7 467- 6ES7 467- 6ES7 467-
5GJ02-0AB0 5FJ00-0AB0 5GJ02-0AB0 5FJ00-0AB0
Supply voltages Environmental requirements
Rated value Operating temperature
- 5 V DC Yes; +/- 5 % Yes; +/- 5 % - min. 0 °C 0 °C
- 24 V DC Yes; +/- 5 % Yes; +/- 5 % - max. 60 °C 60 °C
Current consumption Storage/transportation temperature
• from backplane bus 5 V DC, max. 1,300 mA 1,300 mA - min. -40 °C -40 °C
Configuration - max. 70 °C 70 °C
• Number of modules per CPU 10 in CR 10 in CR
Air pressure
(depending on (depending on
CPU type) CPU type) - Altitude above MSL, max. 3,000 m 3,000 m
1st interface Relative humidity
• Type of interface 9-pin 2 x duplex - Operation, max. 95 %; 95 %;
sub-D female socket at 26°C at 26°C
connector Dimensions and weight
• Physical RS 485 FO/Lamda =
660 nm • Weight, approx. 700 g 700 g
Functionality • Width 25 mm 25 mm
- DP master Yes Yes • Height 290 mm 290 mm
DP master • Depth 210 mm 210 mm
- Number of connections, max. 32; depending 32; depending
on the CPU on the CPU
type type
• Services
- Equidistance support Yes Yes
- Direct data exchange Yes Yes
(lateral communication)
- Transmission rates, max. 12 Mbit/s 12 Mbit/s; not
3 and 6 Mbit/s
- Transmission rates, min. 9.6 kBit/s 9.6 kBit/s
- Number of DP slaves, max. 96 96
• Address area
- Inputs, max. 4 KByte 4 KByte
- Outputs, max. 4 KByte 4 KByte
• User data per DP Slave
- Inputs, max. 244 Byte 244 Byte
- Outputs, max. 244 Byte 244 Byte
■ Overview
• Power supplies for the SIMATIC S7-400
• For conversion of AC or DC ne twork voltages into the required
5 V and 24 V DC operating voltages
• Output current 4 A, 10 A and 20 A
■ Technical specifications
6ES7 405-0DA01-0AA0 6ES7 405-0KA01-0AA0 6ES7 405-0KR00-0AA0 6ES7 405-0RA01-0AA0
Power supply
• Line supply/voltage failure 4.5 ms; +/- 0.5 ms 20 ms 20 ms 20 ms
buffering
• Line supply/voltage failure No Yes Yes Yes
buffering to comply with
the NAMUR recommendation
Input voltage
- Rated value, 24 V DC Yes Yes Yes Yes
- Rated value, 48 V DC Yes Yes Yes
- Rated value, 60 V DC Yes Yes Yes
- permissible range, static 19.2 V static 19.2 V static 19.2 V static 19.2 V
lower limit (DC) dynamic 18.5 V dynamic 18.5 V dynamic 18.5 V dynamic 18.5 V
- permissible range, static 30 V Static: 72 V; static: 72 V static: 72 V
upper limit (DC) dynamic 30.2 V dynamic 75.5 V dynamic 75.5 V dynamic 75.5 V
Input current
- Rated value at 24 V DC 2A 4.5 A 4.5 A 7.3 A
- Rated value at 48 V DC 2.1 A 2.1 A 3.45 A
- Rated value at 60 V DC 1.7 A 1.7 A 2.75 A
- Inrush current, max. 27 A; 18 A; 18 A; 33 A;
Half-value width 10 ms Half-value width 20 ms Half-value width 20 ms Half-value width 1.5 ms
Output voltage
- Rated value, 5 V DC Yes Yes Yes Yes
- Rated value, 24 V DC Yes Yes Yes Yes
Output current
- for backplane bus (5 V DC), 4 A; 100 mA base load 10 A; 200 mA base load 10 A; 200 mA base load 20 A; 200 mA base load
max. required required required required
- for backplane bus (24 V DC), 0.5 A; idling-proof 1 A; idling-proof 1 A; idling-proof 1 A; idling-proof
max.
- Short-circuit protection Yes Yes Yes Yes
Voltages and currents
• Power consumption, typical 48 W 104 W 104 W 175 W
Current consumption
• Power dissipation, typical 16 W 29 W 29 W 51 W
Back-up battery
- Backup battery (optional) Yes; 1 x lithium AA; Yes; 2 x lithium AA; Yes; 2 x lithium AA; Yes; 2 x lithium AA;
3.6 V/1.9 Ah 3.6 V/1.9 Ah 3.6 V/1.9 Ah 3.6 V/1.9 Ah
Connection system
• Connecting cables/ 3 x 1.5 mm2, solid 3 x 1.5 mm2, solid 3 x 1.5 mm2, solid 3 x 1.5 mm2, solid
cross-sections or stranded wire, outer or stranded wire, outer or stranded wire, outer or stranded wire, outer
diameter 3 to 9 mm diameter 3 to 9 mm diameter 3 to 9 mm diameter 3 to 9 mm
Potentials/ electrical isolation
• primary/secondary Yes Yes Yes Yes
■ Overview
Labeling sheets Additional information is available in the Internet under:
• Film sheets for application- specific labeling of SIMATIC http://www.s7-smartlabel.com
S7-400 I/O modules with commercial laser printers
• Single-color films, tear-resistant, dirt-resistant Label cover
• Easy handling: • Film to cover and hold user -made labeling strips on
- Pre-perforated labeling sheets in DIN A4 format to allow normal paper
easy separation of the labeling strips • Accessories, 10 items
- The separated strips can be inserted directly into
the I/O modules
Different colors for distinction between module types
5 or preferred areas of application:
The labeling sheets are available in the colors teal, light beige,
red and yellow. Yellow is reserved for failsafe systems.
■ Technical specifications
6ES7 492- 6ES7 492- 6ES7 492- 6ES7 492- 6ES7 492-
2AX00-0AA0 2BX00-0AA0 2CX00-0AA0 2DX00-0AA0 2XX00-0AA0
Dimensions and weight
• Weight, approx. 2g 2g 2g 2g 72 g
■ Overview
Cover film for labeling strips Power plug
• Petrol-colored film for covering and fixing user-created labe- • Plug for connecting the PS 405 and PS 407 power supply
ling strips. modules to the line supply
• On standard paper • Spare part
• Spare part Exchangeable fan
Measuring range module for analog input modules • Fan unit for installation in the fan subassembly
• Plug-in module for select ing the input ranges for • Spare part
analog modules
Exchangeable monitoring unit
• 1 module for 2 inputs
• Spare part
• Electronic monitoring unit for the fan subassembly
• Spare part
5
Module slot cover
Exchangeable power supply unit
• Cover plates for unassigned sl ots in module mounting racks
• Power supply unit for installa tion in the fan subassembly
• Spare part, 10 items
• Spare part
6/2 Introduction
Siemens ST 70 · 2005
SIMATIC C7
SIMATIC C7
Introduction
SIMATIC C7
■ Overview
• Control systems for the low-end performance range
• Combines SIMATIC S7-300 programmable controller and
SIMATIC operator panel in one unit
• Ultra-compact comple te machine control
• Highly suitable for industrial use
• User-friendly operation, simp le fan-free configuration and
reduced installation effort
• Easily adaptable to increasing requirements through the use
of the extensive range of S7-300 modules
■ Overview
• The low-cost entry point in th e world of SIMATIC C7 control
systems
• For all applications which require fast PLC performance and
easy to use human-machine interface functionality
• With user-friendly, onboard I/O for space-saving implementa-
tion at the machine level
• Integrated technology functions for counting, frequency
measurement and closed-loop control
A micro memory card and connector set are required for C7
operation.
6
■ Technical specifications
6ES7 613-1CA01-0AE3 6ES7 613-1CA01-0AE3
Supply voltages OB
Rated value - Size, max. 16 KByte
- 24 V DC Yes Nesting depth
- permissible range, 20.4 V - per priority class 6
lower limit (DC)
- additional levels within an 4
- permissible range, 28.8 V error OB
upper limit (DC)
CPU/processing times
Current consumption
• for bit instruction, min. 0.1 µs
• Inrush current, max. 1A
• for bit instruction, max. 0.2 µs
• Current consumption, typical 350 mA; idling
• for word instruction, min. 0.5 µs
Digital outputs • for integer math, min. 1 µs
• Power dissipation, typical 11 W • for floating-point math, min. 15 µs
Memory/backup Timers/counters
and their retentive characteristics
Memory
S7 counter
- Micro memory card Yes; all the data are on the
MMC of the CPU - Number 256
• Working memory • of which retentive without battery
- integral 32 KByte; for program and - adjustable Yes
data, less the display data - lower limit 0
- expandable No - upper limit 256
• Load memory • Counting range
- expandable FEPROM with Micro Memory Card (MMC) - lower limit 0
• User memory - upper limit 999
- integral see CPU working memory IEC counter
Backup - available Yes
- available Yes; guaranteed by MMC - Type SFB, unlimited quantity
(maintenance-free) (only limited by working memory)
- without battery Yes; Program and data
S7 times
CPU/blocks - Number 256
DB • of which retentive without battery
- Number, max. 127; DB 0 reserved - adjustable Yes
- Size, max. 16 KByte - lower limit 0
- upper limit 256
FB
• Timing range
- Number, max. 128
- lower limit 10 ms
- Size, max. 16 KByte - upper limit 9,990 s
FC IEC timer
- Number, max. 128 - available Yes
- Size, max. 16 KByte - Type SFB
• Number 3
■ Overview
• Cost-effective control systems
• For all applications which require fast PLC performance and
easy to use human-machine interface functionality
• Featuring larger RAM for extensive application programs
• With the user-friendly control functions of the SIMATIC OP7
operator panel
6
■ Technical specifications
6ES7 633- 6ES7 633- 6ES7 633- 6ES7 633-
1DF02-0AE3 2BF02-0AE3 1DF02-0AE3 2BF02-0AE3
Supply voltages CPU/blocks
Rated value DB
- 24 V DC Yes Yes - Number, max. 255; DB 0 255; DB 0
- permissible range, 20.4 V 20.4 V reserved reserved
lower limit (DC)
FB
- permissible range, 30.2 V 30.2 V
upper limit (DC) - Number, max. 192; see 192; see
instruction list instruction list
Current consumption
FC
• Current consumption, max. 1A 1A
- Number, max. 192; see 192; see
• Current consumption, typical 550 mA 550 mA instruction list instruction list
Digital outputs OB
• Power dissipation, typical 12 W 12 W - Number, max. see instruction see instruction
Memory/backup list list
■ Overview
• Control systems for advanced applications
• With onboard I/O for use at machine level
• With integrated PROFIBUS DP connection for distributed
structures
• Variant with context-sensitive touch functionality
• Graphical visualization and operator support for particularly
convenient use
A micro memory card and connector set are required for C7
operation.
6
■ Technical specifications
6ES7 635- 6ES7 635- 6ES7 635- 6ES7 635-
2EC01-0AE3 2EB01-0AE3 2EC01-0AE3 2EB01-0AE3
Supply voltages CPU/blocks
Rated value DB
- 24 V DC Yes Yes - Number, max. 511; DB 0 511; DB 0
- permissible range, 20.4 V 20.4 V reserved reserved
lower limit (DC)
- Size, max. 16 KByte 16 KByte
- permissible range, 28. V 28.8 V
upper limit (DC) FB
Current consumption - Number, max. 512; see 512; see
instruction list instruction list
• Inrush current, max. 1A 1A
- Size, max. 16 KByte 16 KByte
• Current consumption, max. 1A 1A
FC
• Current consumption, typical 350 mA; 350 mA;
idling idling - Number, max. 512; see 512; see
instruction list instruction list
Digital input
- Size, max. 16 KByte 16 KByte
- from load voltage L+ 70 mA 70 mA
(without load), max. OB
Digital outputs - Number, max. see see
- from load voltage L+, max. 20 mA; 20 mA; instruction list instruction list
per group per group - Size, max. 16 KByte 16 KByte
• Power dissipation, typical 14 W 14 W
Nesting depth
Memory/backup - per priority class 8 8
Memory - additional levels within 4 4
- Micro memory card Yes Yes an error OB
- Compact flash card Yes; optional Yes; optional CPU/processing times
• Working memory
• for bit instruction, min. 0.1 µs 0.1 µs
- integral 64 KByte 64 KByte
• for word instruction, min. 0.2 µs 0.2 µs
- expandable No No
• Load memory • for integer math, min. 2 µs 2 µs
- pluggable (MMC) Yes Yes • for floating-point math, min. 6 µs 6 µs
- pluggable (MMC), max. 8 MByte 8 MByte
• User memory
- integral 768 KByte; for 768 KByte;for
configuring configuring
the panel the panel
Backup
- available Yes; guaran- Yes; guaran-
teed by MMC teed by MMC
(maintenance- (maintenance-
free) free)
• Isolated No No DP master
- Number of connections, max.
• Power supply to interface 200 mA 200 mA
(15 to 30 V DC), max. • Services 12 12
Functionality - PG/OP communication Yes Yes
- MPI Yes Yes - Routing Yes; Yes;
only when inter- only when inter-
6 MPI
- Number of connections 12 12 - Global data communication
faces active
No
faces active
No
• Services - S7 basic communication No No
- PG/OP communication Yes Yes - S7 communication No No
- Routing Yes Yes - Direct data exchange Yes Yes
- Global data communication Yes Yes (lateral communication)
- S7 basic communication Yes Yes - DPV1 No No
- S7 communication Yes Yes - Transmission rates, max. 12 Mbit/s 12 Mbit/s
- S7 communication, as client Yes; via CP and Yes; via CP and • Intermediate memory
loadable FB loadable FB - Inputs 244 Byte 244 Byte
- S7 communication, as server Yes Yes - Outputs 244 Byte 244 Byte
- Transmission rates, max. 187.5 kBit/s 187.5 kBit/s - Address areas, max. 32 32
2nd interface - User data per address area, 32 Byte 32 Byte
max.
• Type of interface integrated integrated
RS 485 RS 485 CPU/ programming
interface interface
Configuration software
• Physical RS485 RS485 - ProTool Yes; Yes;
• Isolated Yes Yes or SIMATIC or SIMATIC
ProTool/Pro ProTool/Pro
• Power supply to interface 200 mA 200 mA Configuration Configuration
(15 to 30 V DC), max. as of Version as of Version
• Number of connection resources 12 12 6.0 SP1 6.0 SP1
- ProTool/Lite Yes Yes
Functionality
- ProTool/Pro Yes; Also flexi- Yes; Also flexi-
- MPI No No ble configura- ble configura-
- DP master Yes Yes tion with WinCC tion with WinCC
- DP slave Yes Yes Programming language
DP master - LAD Yes Yes
- Number of connections, max. 12 12
- FBD Yes Yes
- Number of connections 1 for PG, 1 for PG,
(of which reserved), max. 1 for OP 1 for OP - STL Yes Yes
• Services - SCL Yes Yes
- PG/OP communication Yes Yes - CFC Yes Yes
- Routing Yes Yes - GRAPH Yes Yes
- Global data communication No No
- HiGraph® Yes Yes
- S7 basic communication No No
Software library
- S7 communication No No
- S7 communication, as client No No • Instruction set see see
instruction list instruction list
- S7 communication, as server No No
- Equidistance support Yes Yes • Bracket levels 8 8
- SYNC/FREEZE Yes Yes • User program protection/pass- Yes Yes
- Activate/deactivate Yes Yes word protection
DP slaves • System functions (SFC) see see
- Direct data exchange Yes Yes instruction list instruction list
(lateral communication) • System function blocks (SFB) see see
- Transmission rates, max. 12 Mbit/s 12 Mbit/s instruction list instruction list
- Number of DP slaves, max. 32 32
■ Overview
• Compact units for comprehensive applications
• The CPU with medium to large program memory and quantity
framework for the use, if required, of SIMATIC Engineering
Tools
• High processing performance in binary and floating-point
arithmetic
• Full graphics 5.7" STN di splay, color (256 colors)
• 36 system keys, 24 user-configu rable function keys which can
be labeled as required (18 with an LED)
• With onboard I/O for use at machine level
• With integrated PROFIBUS DP connection for distributed
structures
• Graphical and color visualizat ion and operator support for
particularly user-friendly use
6 A micro memory card and connector set are required for C7
operation.
■ Technical specifications
6ES7 636-2EC00-0AE3 6ES7 636-2EC00-0AE3
Supply voltages CPU/blocks
Rated value DB
- 24 V DC Yes - Number, max. 1,023; DB 0 reserved
- permissible range, 20.4 V - Size, max. 16 KByte
lower limit (DC)
FB
- permissible range, 28.8 V
upper limit (DC) - Number, max. 2,048; see instruction list
- Size, max. 16 KByte
Current consumption
• Inrush current, max. 3 A; 3 A for 10 ms, FC
then 2 A for 70 ms - Number, max. 2,048; see instruction list
• Current consumption, max. 1.3 A - Size, max. 16 KByte
• Current consumption, typical 450 mA; idling OB
Digital outputs - Number, max. see instruction list
• Power dissipation, typical 19 W - Size, max. 16 KByte
Back-up battery Nesting depth
- Backup battery (optional) Yes - per priority class 8
Memory/backup - additional levels within 4
an error OB
Memory
CPU/processing times
- Micro memory card Yes
• for bit instruction, min. 0.1 µs
• Working memory
- integral 128 KByte • for word instruction, min. 0.2 µs
- expandable No • for integer math, min. 2 µs
• Load memory • for floating-point math, min. 6 µs
- pluggable (MMC) Yes Timers/counters and their
- pluggable (MMC), max. 8 MByte retentive characteristics
S7 counter
• User memory
- Number 256
- integral 2 MByte; (Flash) for configuring
the panel • of which retentive without battery
Backup - adjustable Yes
- available Yes; guaranteed by MMC - lower limit 0
(maintenance-free) - upper limit 256
- with battery Yes; Option for the panel • Retentivity
- without battery Yes; CPU program and data - adjustable Yes
- preset Z 0 to Z 7
• Counting range
- lower limit 0
- upper limit 999
Siemens ST 70 · 2005
SIMATIC Industrie Software
■ Overview
• System of seamlessly integrated software tools for
SIMATIC S7 and PC-based Control SIMATIC WinAC
• User-friendly functions for all ph ases of an automation project
• Consists of:
- Standard tools:
Basis for the SIMATIC hardware
- Engineering tools:
High-level programming languages and technology-
oriented software
- Runtime software:
Ready-to-use runtime software for the production process
- Human Machine Interface:
Software specifically for operator control and monitoring
■ Overview
CP 5512
• For PGs/PCs/notebooks with PCMCIA slot
• PCMCIA card type II (Cardbus 32-bit)
• Incl. adapter with 9-pin Sub D socket for connection to
PROFIBUS
CP 5611 or CP 5611-MPI
• For PGs/PCs with a PCI slot
• Short PCI card (32-bit)
• CP 5611 MPI including MPI cable
Components for connecting the PC to Industrial Ethernet
The PC modules described below support, in combination with
the software STEP 7 and SOFTNET-PG (V6.0 or later) for
Industrial Ethernet, the connection of programming devices and
AT-compatible PCs or notebooks to Industrial Ethernet.
CP 1512
• For PGs/PCs/notebooks with PCMCIA slot
• PCMCIA card type II (Cardbus 32-bit); 10/100 Mbps
• STEP 7 basic software:
The standard tool for the SIMATIC S7, SIMATIC C7 and • Incl. adapter with RJ45 socket for connection to Industrial 7
SIMATIC WinAC automation systems. Ethernet
• Makes use of the full performance capabilities of the systems CP 1612
• User-friendly functions for all ph ases of an automation project: • For PGs/PCs with a PCI slot
- Configuring and parameterizing the hardware
- Definition of communication • Short PCI card (32-bit); 10/100 Mbps
- Programming • With RJ45 socket for connection to Industrial Ethernet
- Testing, commissioning and service For technical details concerning versions and supported opera-
- Documentation, archiving ting systems, please refer to the catalog data for the respective
- Operating, diagnostics function products.
Components for connection of the PC to MPI and PROFIBUS For further information about online connection of PCs and
The PC modules described below support, in combination with SIMATIC S7/C7 controllers, see "SIMATIC NET Communication
STEP 7, the connection of programming devices and Systems" in the catalog IK PI or in the A&D Mall.
AT-compatible PCs or notebooks to PROFIBUS and the MPI of
SIMATIC S7.
PC adapter USB
• For connecting a PC to the SIMATIC S7 automation system via
the USB interface
• Can be connected to USB 1.1 and 2.0 interfaces
• For use with SIMATIC S7-300 and S7-400
• Supports routing
• Automatic transmission rate and profile search
• Significantly enhanced performance (up to 3 times faster than
the PC adapter via RS 232)
• With firmware that can be upgr aded in the future, e.g., for
function expansion or error rectification
• Can be used with Windows 2000, Windows XP Home and
Windows XP Professional
• Scope of supply:
- PC adapter USB
- CD "SIMATIC Software PC Adapter USB" with software and
documentation
- USB cable, 5 m
- MPI cable, 0.3 m
For the technical specifications of STEP 7, see "Standard Tools". STEP 7 Version 5.3
Target system:
PC Adapter USB SIMATIC S7-300/-400,
SIMATIC C7, SIMATIC WinAC
Dimensions (W x H x D) in mm, 105 x 58 x 26 Prerequisite:
approx. Windows 2000 Prof./XP Prof.
Weight, approx. 100 g Delivery package:
German, English, French,
Supply voltage 24 V DC/ 100 mA Spanish, Italian;
incl. 3.5” automation disk,
Max. power consumption. 2.5 W without documentation
Electromagnetic compatibility Floating license on CD 6ES7 810-4CC07-0YA5
(EMC) Floating license on CD, Japanese 6ES7 810-4CC07-0JA5
Noise emission Limit class B acc. to EN 55022 Software Update Service on CD 6ES7 810-4BC01-0YX2
Immunity to fault voltages on supply 2 kV (as per IEC 61000-4-4; burst) Upgrade floating license 6ES7 810-4CC07-0YE5
cables 1 kV (as per IEC 61000-4-5; V2.x/3.x/4.x/5.x to V5.3; on CD
symm. surge) Upgrade floating license 6ES7 810-4CC07-0JE5
V2.x/3.x/4.x/5.x to V5.3,
2 kV (as per IEC 61000-4-5;
Japanese; on CD
asymm. surge)
Powerpack STEP 7 Lite according 6ES7 810-4CC07-0YC5
Immunity to signal line interference 1 kV (as per IEC 61000-4-4; burst; to STEP 7 V5.3;
length < 3 m) Floating license on CD
7 2 kV (as per IEC 61000-4-4; burst;
length > 3 m)
Trial license STEP 7 V5.3;
on CD, can be used for 14 days
6ES7 810-4CC07-0YA7
■ Overview
STEP 7 Professional supports all IEC languages. An offline simulation of programs created with these languages
is included. STEP 7 Professional thus replaces the combination
In addition to the languages recognized by STEP 7 of the individual packages STEP 7, S7-GRAPH, S7-SCL and
• LAD S7-PLCSIM.
• FBD A POWERPACK is offered to customers who use STEP 7 already
• IL and wish to change. A valid STEP 7 license is required for
purchasing the POWERPACK. A separate update service is
The following are also available: available for STEP 7 Professional.
• "Sequential Function Chart"
• "Structured Text"
■ Technical specifications
Standard tool STEP 7 Professional STEP 7 STEP 7 Lite STEP 7-Micro/WIN
License form Floating license Floating license Floating license Single license
Software class A A A A
Current version Edition 2004 V 5.3 V 3.0 V4.0
Target system SIMATIC S7-300 SIMATIC S7-300 SIMATIC S7-300 SIMATIC S7-200
SIMATIC S7-400 SIMATIC S7-400 SIMATIC C7
SIMATIC C7 SIMATIC C7
Operating system Windows 2000 Windows 2000 Windows XP Home Windows 2000
Professional Professional Windows 2000 Windows XP
Windows XP Professional Windows XP Professional Professional
Windows XP Professional
Memory configuration Depending on the Micro- Depending on the Micro- Depending on the Micro- 32 MB
in PG/PC, min. soft Windows operating soft Windows operating soft Windows operating
system used. system used. system used.
Recommended: 256 MB Recommended: 256 MB Recommended: 128 MB
Disk space requirement Depending on installation Depending on installation Depending on installation 50 MB
in PG/PC 200 to 430 MB 200 to 380 MB 90 to 250 MB.
Size of user program in CPU About factor 1.5 About factor 1.5 About factor 1.5 Approx. 1.0
compared to STEP 5 compared to STEP 5 compared to STEP 5 times larger than STEP 5
7 Note
for IL, LAD, CSF
Contains all 5 IEC pro-
for IL, LAD, CSF
-
for IL, LAD, CSF
For non-networked
with IL, LAD
Single license
gramming languages - applications with
LAD, CSF, IL, SCL, central I/O.
and GRAPH - and PLC
simulation software
S7-PLCSIM
7 sequencers
• Standardized representation to DIN EN 1131-3
5 languages: S7-200/300/400,
C7, LOGO!, SIMATIC DP, PC, PG,
STEP 7, Engineering Software,
Runtime Software, PCS 7,
• Clearly comprehensible progra m thanks to structuring of the SIMATIC HMI, SIMATIC NET
process into separate steps
SIMATIC Manual Collection 6ES7 998-8XC01-8YE2
• With extensive diagnostics func tions, integrated into the update service for 1 year B)
SIMATIC diagnostics concept
Up-to-date Manual Collection CD
• With PLCopen Base Level certificate as well as the three subsequent
• For use in SIMATIC S7-300 (recommended for CPU 315 and updates
CPU 312C or higher), S7-400, C7 and WinAC B) Subject to export regulations: AL: N and ECCN: EAR99S
which function blocks created by the user can be added in 5 languages: S7-200/300/400,
• Reduced costs and fewer mistak es by simply interconnecting C7, LOGO!, SIMATIC DP, PC, PG,
read-to-use function blocks STEP 7, engineering software,
runtime software, PCS 7,
• Optimized integration in the world of automation, for example, SIMATIC HMI, SIMATIC NET
through guaranteed compatibility with all STEP 7 tools
SIMATIC Manual Collection 6ES7 998-8XC01-8YE2
• Can be used for SIMATIC S7-3 00 (recommended for CPU 316 update service for 1 year B)
or CPU 314C or higher), SIMATIC S7-400, SIMATIC WinAC Current Manual Collection CD
and D7-SYS as well as the three following
updates
B) Subject to export regulations: AL: N and ECCN: EAR99S
■ Overview
• For remote maintenance of SIMATIC S7/C7 automation
systems using a wired or radio network
Fixed or
D
• Functions:
radio network Modem PG/PC - Access to remote plants (remote maintenance):
(PG/PC) Distributed plants can be managed, controlled and
monitored centrally using remote connections
(can be used in SIMATIC S7-300 and S7-400).
- Establishment of connection from/to remote plants
Modem (Plant) (PG-AS remote coupling)
TS
- Data exchange between plants (AS-AS remote coupling):
Adapter MPI Exchange of process data between two SIMATIC automation
systems via the telephone networ
- Sending a text message:
A SIMATIC automation system can send a text message via
a GSM radio modem.
S7-400 S7-300 C7 • For use on the SIMATIC S7-300, S7-400, C7
PROFIBUS DP
DP Slave S7-CPU
7
■ Technical specifications
See "Engineering Tools" for Technical specifications of TeleService.
TS Adapter TS Adapter II
Dimensions (W x H x D) in mm 50 x 24 x 108 Dimensions (W x H x D) in mm 125 x 110 x 40
Weight, approx. 150 g Weight, approx. 250 g
Interfaces Interfaces
• To S7/C7 RS 485 (max. 1.5 Mbit/s) • To S7/C7 RS 485 (max. 12 Mbit/s)
• To PG/PC RS 232 (19.2 Kbit/s or 38.4 Kbit/s, • to the PC USB 1.1 (12 Mbit/s)
switch-selectable)
• to the external modem RS 232 (up to 115 Kbaud)
Supply voltage VN VN1: 24 V DC • to the analog telephone network RJ12
VN2: 5 V DC
• to the ISDN telephone network RJ45
Current consumption IN, typ. I1: 50 mA
I2: 40 mA Supply voltage external or through 24 V DC
MPI interface
Inrush current, max. I1: 0.5 A; 14 ms
I2: 0.2 A; 1.5 ms Current consumption 60 mA (typ.) / 120mA (max.)
Degree of protection IP 20 Inrush current, max. 0.7 A; 8 µs
Temperature Degree of protection IP 20
• Operation ± 0 °C to +60 °C Temperature
• Storage/transport -40 °C to +70 °C • Operation ± 0 °C to +60 °C
• Storage/transport -40 °C to +70 °C
■ Overview
• Component-based software tool for configuration of
communication in distributed automation solutions
• Based on PROFINET standard
• For simple graphic configuring of communication between
system modules and machine-machine on the production line
• Open for PROFINET devices from different vendors on
Industrial Ethernet
• Runs on Windows 2000 and Windows XP
■ Technical specifications
Engineering tool SIMATIC iMap Target systems • SIMATIC S7 CPU 317-2 PN/DP
(with integrated PROFINET
Current version V2.0 interface. Can be used as
a proxy for the devices of a
Software class A complete PROFIBUS segment,
Applications only one line.)
• SIMATIC WinAC PN
Slogan SIMATIC iMap is an engineering
(can be used as a proxy for the
tool for configuration of
devices of a complete
communication between intelli-
PROFIBUS segment, only one
gent automation systems and
line)
field devices in distributed
automation solutions. • SIMATIC NET IE/PB Link
(can be used as a proxy for the
Marketing message "Reduction in time and costs for devices of a complete
modular machine and plant PROFIBUS segment)
construction using Component
based Automation." • SIMATIC NET
“Modularization and machine- CP 343-1 PN (for connecting the
machine communication along SIMATIC S7-300 to Ethernet),
the production line“ CP443-1 Advanced (for
connecting the SIMATIC S7-400
Advantages • Neutral component-based to Ethernet)
engineering tool in conformance • Distributed I/O stations with
with the PROFINET standard. own CPU
7 • Simple communication
between intelligent automation
(all intelligent field devices on
the PROFIBUS such as
systems and field devices on SIMATIC CPU 313C-2DP,
PROFIBUS DP and on the CPU 314C-2DP,
Ethernet. CPU 315-2DP, CPU 316-2DP,
• Graphic configuring of ET 200 IM 151 CPU, ET 200S
communication on BM 147 CPU),
PROFIBUS DP and on the • PROFINET OPC server
Ethernet (for access from PC applications
• Very high reusability of the to data in PROFINET devices)
software components • Devices on Industrial Ethernet
(technological modules) based on the PROFINET CBA
• Graphic configuring of plant standard
using chart-in-chart function • SIMATIC OPs (within the
• Convenient navigation in components)
project tree • SIMATIC ProTool/Pro, WinCC
• Convenient generation and or any other visualization system
structuring of technological with OPC client function
libraries
• PROFIBUS and Ethernet in
overview in the network view
• Fast startup by downloading
and testing directly on the
Ethernet (also of PROFIBUS
slaves)
• Online display of values of
technological modules on
the interfaces and in the
variables table
• Diagnostics of communication
in the diagnostics window
Sectors • Automotive industry (especially
for assembly, conveyor systems
and paint shops)
• More complex food and
packaging machines
• Conveyor systems based on
PROFIBUS DP
• Production lines with several
combined machines
A software update service can also be purchased for the Drive ES Basic V 5.3
Drive ES software. The user is automatically supplied with the Update service for single license 6SW1 700-0JA00-0AB2
current software, service packs and complete versions for one Update service for copy license 6SW1 700-0JA00-1AB2
year after the date of ordering.
Drive ES Graphic 6SW1 700-0JB00-0AB2
The update service can only be ordered if the customer already Update service for single license
has a complete version of the software.
Drive ES SIMATIC V 5.3 6SW1 700-0JC00-0AB2
• Duration of the update service: 1 year.
Update service for single license
6 weeks before expiry, the customer and his Siemens contact Drive ES PCS 7 V 6.0 6SW1 700-0JD00-0AB2
will be informed in writing that the update service will automati-
cally be extended by another year if it is not cancelled on the Update service for single license
part of the customer.
■ Technical specifications
Engineering Tool S7-SCL S7-GRAPH
Current version V5.3 V5.3
Software class A A
Applications
Can be used for Text high-level language programming of simple Graphical programming of sequential control systems
and complex calculations, CASE, loop, jump and and sequencers
compare functions
Marketing message Programming of algorithms and calculations made The fast and elegant way to program sequential
easy! processes in a simple and clear manner!
Advantages • Easy-to-read and clear programs • Ready for optimum use in the design phase
• Functional module-oriented programming • Lower configuration overhead due to graphical
• CASE instruction replaces a large number of jump structuring and programming
and compare functions • Rapid and easy familiarization
• Simple change for PLC programmers, since the • Precise error locating by means of integrated
programming philosophy of LAD, CSF, and IL is diagnostics combined with ProAgent for ProTool/Pro
retained and WinCC
• Simple change for PC programmers to PLC • Saving of time on engi neering overhead compared
programming to LAD, CSF, and IL: Approximately 40 to 70%
• Interchangeability (porting) of partial programs as
specified in IEC 61131-3
• Saving of time on engineering overhead compared to
LAD, CSF, and IL: Up to 20% with simple programs; 7
at least 50% with sophisticated program structures
Sectors • Labeling machines • Automobile production (e.g ., body-in-white, final
• Chemical plants (e.g., oxygen production, assembly)
evaluation of measured values) • Electrical equipment manufacture
• Rubber and plastics machines • Rubber and plastics machines
• Woodworking machinery • Handling machines
• Warehouse systems and logistics • Woodworking machinery
• Paper processing an d printing machines • Metalworking machinery
• Punching and cutting machines • Paper processing and printing machines
• Water industry • Testing machines
• Reeling machines • Rolling mills
• Reeling machines
• Leisure and entertainment facilities
Target systems
Suitable for use on S7-300 (CPU 313 or later and CPU 312C or later S7-300 (CPU 314 or later and CPU 312C or later
recommended) recommended)
S7-400 S7-400
C7 (recommended for C7-626) C7 (recommended for C7-626)
WinAC WinAC
System requirements
Operating system Windows 2000 Professional Windows 2000 Professional
Windows XP Professional Windows XP Professional
Hard disk requirements on PG/PC 8 MB 15 MB
approx.
Required software STEP 7 V5.3 STEP 7 V5.3
Features
Monitor tags Yes Yes
Modify tags Yes Yes
Single-step processing Yes Yes
Integration in CFC Yes -
Program execution times
For S7-300 (typically) Similar to LAD, CSF and IL 3 ms per block +
1 ms per active step
For S7-400 (typically) Similar to LAD, CSF and IL 0.4 ms per block +
0.06 ms per active step
Diagnostics
Integration of diagnostic data in - Yes
ProAgent
Integration of diagnostic data in - Using ProAgent
ProTool/Pro
Integration of diagnostic data in - Using ProAgent
WinCC
7 Authorization floppy
Certificate of License
Product information sheet
Authorization floppy
Certificate of License
Product information sheet
Software update service (SUS)
Also included in
STEP 7 Professional Yes Yes
S7 Trainer Package Yes Yes
PCS 7 Yes -
D7-SYS - -
■ Overview
• For integrating continuous PI D controllers, pulse controllers
and step controllers in the application program
• Reduces engineering costs thanks to space-saving
parameterization and optimization of the controller
• For use in SIMATIC S7-300 (CPU 313 or higher), S7-400
and C7
■ Technical specifications
Parameterization tool data 7
Requirements STEP 7 V5.2 or newer
■ Overview
• For creating complex closed-loop control structures
• Preferred for implementation in closed-loop control equipment
in mid-range and high-end applications and in process
engineering
• For use in SIMATIC S7-300 (CPU 313 or newer), S7-400
and C7
7 ■ Technical specifications
Startup software
Requirements STEP 7 V3.1 or higher
Main memory expansion 16 MB
Processor, at least 486
Windows swap area, approx 20 MB (largest possible)
■ Overview
• PID Self-Tuner: For extending exis ting PID controllers into self- • Ideal application is in temper ature controllers, but also sui-
setting PI or PID controllers. table for level and flow controllers
• Optimization of PI or PID co ntrollers with 3-step action • Used with SIMATIC S7-300 (CPU 313 upwards), SIMATIC S7-
(HEATING – OFF – COOLING) 400 and SIMATIC C7; in combination with PID Control (integra-
• Convenient online initial settin g and online adaptation during ted in STEP 7), standard PID Control, modular PID Control,
operation FM 355, FM 455 as well as with any PID algorithm
■ Technical specifications
PID Self-Tuner TUN_EC TUN_ES
Memory requirements Load memory RAM Load memory RAM
• FB length in memory approx. 6542 bytes approx. 5956 bytes 6332 bytes 5714 bytes
• DB length in memory 644 bytes 294 bytes 638 bytes 288 bytes
Runtimes
• in S7-300, C7 1.0 to 1.5 ms1) 1.0 to 1.5 ms1)
• in S7-400 0.06 to 0.19 ms1) 0.06 to 0.19 ms1)
1) Depending on the selected CPU
■ Overview
• For creating Fuzzy systems for SIMATIC S7 and SIMATIC
WinCC
• For use at all levels of automat ion from the standalone controller
through to plant optimization
• Can be combined with classical PID controllers to utilize the
advantages of both systems for optimized closed-loop control
■ Technical specifications
7 Configuring tool
Processor
Requirements
PC or PG with 80486 processor
(or higher)
Main memory, min. 16 MB RAM
Hard disk 5 MB free storage space
on the hard disk
Operating system Windows 95 or
Windows NT 4.0
Standard function blocks FUZZY_4K (FB 30) FUZZY_20K (FB 31) FUZZY_WinCC
Target system SIMATIC S7-300 from CPU 314, SIMATIC S7-400 SIMATIC WinCC
SIMATIC S7-400
Communication between PC/PG MPI bus, SOFTNET S7 for MPI bus, SOFTNET S7 for Not required
and S7 PROFIBUS PROFIBUS
Runtimes Depending on the number of rules, Depending on the number of rules, Cannot be measured
inputs and outputs: 13 to 180 ms inputs and outputs: 1.8 to 150 ms
(S7-300) 1.8 to 22 ms (S7-400) (S7-400)
Memory requirements
• FB 1524 byte 1524 byte Cannot be measured
• DB 4228 byte 20612 byte
Number of inputs 8 with up to 7 membership 8 with up to 7 membership 8 with up to 7 membership
functions each functions each functions each
Number of outputs 4 with up to 9 membership 4 with up to 9 membership 4 with up to 9 membership
functions each functions each functions each
Number of rules, max. 200 2000 2000
■ Overview
• For creating and teaching neuronal networks
• For use with problems whose structure and solution are only
partially known
• Applications:
- Data-based optimization
- Identification of characteristics or processes
- Filtering of data
- Data evaluation and interpretation
- Non-linear single and multiple-variable closed-loop control
- Pattern recognition and diagnostics
■ Technical specifications
Configuring tool Requirements
Processor PC or PG with 80486 processor 7
(or higher)
Main memory, min. 16 MB RAM
Hard disk 5 MB free storage space on
the hard disk
Operating system Windows 95 or
Windows NT 4.0
■ Overview
• Driver for MODBUS protocol with RTU message format; Configuring
communication as master or slave
For loading and configuring the driver, the configuration
• Driver for full-duplex protocol for Data Highway Asynchronous package for CP 441-2 and CP 341, V4.0 upwards and
Link from Allen Bradley STEP 7 V4.0 are necessary. The drivers are copy-protected
• Loadable on CP 341 and CP 441-2 (6ES7 441-2AA03-0AE0) by a dongle.
■ Technical specifications
MODBUS master MODBUS slave (continued)
• MODBUS protocol with RTU Adjustable parameters • Data transmission rate
format 300 bit/s up to 76800 bit/s;
• Master/slave coupling: (TTY to 19200 bit/s)
SIMATIC S7 is master • Character frame
• Implemented function codes: • Slave address of CP (1 to 255)
01, 02, 03, 04, 05, 06, 07, 08, • With/without RS 485 mode
11,12,15,16 for two-wire connection
• No V.24 control and signaling • With/without modem mode
lines (ignore scratch character)
• CRC polynomial: • Factor for character delay
X16 + x15 + x2 +1 time 1-10
7 • Interfaces: TTY (20 mA);
V.24 (RS 232 C);
X.27 (RS 422/485) two-wire or
• Number of work DB
(for FB processing)
four-wire • Enabling of memory areas for
writing by master
• Inbox specified on BRCV
• Default input of receive line
• Delay time 3.5 characters when using X.27 interface
or multiple thereof module
• Broadcast message possible • Conversion of MODBUS
Adjustable parameters • Data transmission rate addresses to S7 data areas
300 bit/s up to 76800 bit/s; Data Highway
(TTY to 19200 bit/s)
• Data highway full duplex (DF1)
• Character frame protocol
• With/without RS 485 mode • Interfaces: TTY (20 mA), V.24
for two-wire connections (RS 232C), RS 422/485
(four-wire)
• With/without modem mode
(ignore scratch character) • No “embedded responses”
• Response timer 100 ms to 25.5 s Adjustable parameters • Data transmission rate 300 bit/s
in steps of 100 ms up to 76800 bit/s; (TTY to
19200 bit/s)
• Factor for character delay time
1-10 • Character frame: 7/8 bit; 1/2
stop bits; even/odd/no parity
• Default input of receive line • Inbox DB and data word
when using X.27 interface
module • Timeout for acknowledgment
character: 30 ms to 10 s
MODBUS slave • Number of repeats with NAK:
• MODBUS protocol with RTU 0 to 5
format • Number of ENQ prompts: 0 to 5
• Master/slave coupling: • Duplicate message transmissi-
SIMATIC S7 is slave on detection: On or Off
• Implemented function codes: • Acknowledgment of CP immedi-
01, 02, 03, 04, 05, 06, 08, 15, 16 ately following receipt or only fol-
• No V.24 control and signaling lowing transfer to CPU
line
• CRC polynomial
X16 + x15 + x2 + 1
• Interfaces: TTY (20 mA),
V.24 (RS 232C),
X.27 (RS 422/485) two-wire or
four-wire
• Communication FB 180,
instance DB 180 (use of a
multi-instance)
• Conversion of MODBUS data
address to S7 data areas.
Processed data areas:
DB, bit memories, outputs,
inputs, timers, counters
• Delay time 3.5 characters
or multiple thereof
■ Overview
MPI PROFIBUS Industrial Ethernet
• Software package for assembling fault-tolerant control
systems based on software
Redundancy link • Designed for control systems with single-channel distributed
I/O
Master
• For use in applications with low demands on changeover
Stand by speed, such as the control of hydroelectric power plants,
cooling circuits, traffic flows, level control, measured data
S7-400 S7-300 acquisition
• Inexpensive thanks to the use of standard S7-300 and S7-400
components
• I/O linking with PROFIBUS DP in redundant configuration
e. g. ET 200 ET 200M • Optional control via WinCC operator station
e. g. ET 200 ET 200M
e. g. ET 200 ET 200M
Non-redundant section Redundant section
7
■ Technical specifications
Hardware requirements Software requirements
CPU S7-300: Configuring/programming STEP 7 V4.0
CPU 313C-2 DP, 314C-2 DP, Communication configuration for NCM S7 for PROFIBUS
315-2 DP, 316-2 DP, 318-2 DP redundant PROFIBUS DP
S7-400: all CPUs
Redundancy link of the CPUs MPI, PROFIBUS, Industrial
Ethernet; existing connections
can also be used.
Suitable modules for ET 200M IM153-2;
all DI/O, AI/O for ET 200M;
FM 350-1 counter module
CP 341
■ Overview
• The toolbox for process data traffic between SIMATIC S7,
SIMATIC M7, SIMATIC C7 and a PG/PC
PG/PC • For autonomous handling of data traffic via MPI/PPI
SIMATIC S7/C7
7
■ Ordering data Order No. Order No.
PRODAVE MPI V5.6 for SIMATIC Manual Collection B) 6ES7 998-8XC01-8YE0
Windows 95/98/ME/NT 4.0/
2000 Prof./XP Prof. Electronic manuals on CD-ROM,
5 languages: S7-200/300/400,
Task: C7, LOGO!, SIMATIC DP, PC, PG,
Data coupling between the STEP 7, Engineering Software,
PG/PC and SIMATIC S7/C7 over Runtime Software, PCS 7,
MPI (S7-200 over PPI) SIMATIC HMI, SIMATIC NET
Requirements:
Windows 95/98/ME/NT 4.0/2000 SIMATIC Manual Collection 6ES7 998-8XC01-8YE2
Prof./XP Prof.; CP 5611, update service for 1 year B)
integral MPI or PC adapter Up-to-date Manual Collection CD
Delivery type: as well as the three subsequent
CD incl. electronic documentation updates
(German, English),
Single license B) 6ES7 807-4BA00-0YA0
Copy license, without software 6ES7 807-4BA00-0YA1
and documentation B)
PRODAVE MPI Mini V5.6 for
Windows 95/98/ME/NT 4.0/
2000 Prof./XP Prof.
Task:
Data coupling between the
PG/PC and SIMATIC S7/C7 over
MPI (S7-200 over PPI);
with reduced functional scope)
Requirements:
Windows 95/98/ME/NT 4.0/2000
Prof./XP Prof.; CP 5611,
integral MPI or PC adapter
Delivery type:
CD incl. electronic documentation
(German, English),
Single license B) 6ES7 807-3BA00-0YA0
Copy license, without software 6ES7 807-3BA00-0YA1
and documentation B)
B) Subject to export regulations: AL: N and ECCN: EAR99S
■ Overview
• Low-cost package for simple positioning control and simple Changes in Version 2.0:
gearbox synchronism • Reduction in runtimes of function blocks
• For use with any variable-s peed standard drive, e.g., • Modification of FB names in conformance with PLCopen 1.0
frequency converter, servo drive.
• Gearbox synchronism (MC_GearIn)
• For incremental and absolute sensor
• Driver for CPU 314C (CPU FW Version 2.0 or newer)
• PROFIBUS DP driver for MM4
■ Technical specifications
Supported hardware
Easy Motion Control executes on the following CPUs: • FM 350-1, FM 450-1
• S7-300 with CPU 314 or higher • SIMODRIVE sensor with PROFIBUS DP
• S7-400 • Other actual-value sensing modules (using free drivers)
• C7 with C7-633 or higher Supported modules for setpoint output:
• WinAC. • ET 200S 2AO U
Supported modules for actual-value sensing: • SM 332
• CPU 314C (CPU with FW version 2.0 or newer) • SM 432
7 • ET 200S 1 Count 5V/500 kHz • Other setpoint output modules (using free drivers)
• ET 200S 1 Count 24V/100 kHz Drives supported via PROFIBUS DP:
• ET 200S 1SSI • MM4
• SM 338
Memory requirements
Required RAM in byte
Block Required RAM Additionally required RAM per invocation
per block
MC_Init 1086 -
MC_MoveAbsolute 3924 112
MC_MoveRelative 2982 110
MC_MoveJog 3110 110
MC_Home 2886 104
MC_StopMotion 1114 70
MC_Control 1756 58
MC_Simulation 410 64
MC_GearIn 3476 128
Input drivers 1416 ... 2654 76 ... 128
Output drivers 384 ... 1242 52 ... 68
Axle data block - 294
Runtime load
Typical runtimes of blocks in µs
Block CPU 416-2 DP CPU 314C CPU 315-2 DP WinLC RTX 3.1
6ES7 416-2XK02-AB0 6ES7 314-6CF00-0AB0 6ES7 315-2AF03-0AB0 on AMD, 1333 MHz
MC_Init 53 967 2203 21
MC_MoveAbsolute 1) 67 908 2138 18
MC_MoveRelative 1) 67 911 2143 18
MC_MoveJog 1) 48 605 1387 15
MC_Home 1) 49 592 1332 15
MC_StopMotion 1) 23 309 696 8
MC_Control 27 343 819 11
MC_Simulation 23 259 584 6
MC_GearIn 66 931 2130 21
Input drivers 50 662 1323 44
Output drivers 20 223 413 31
1) The identified motion blocks require more runtime when starting a traverse.
You will find further information on this subject in the manual.
■ Technical specifications
Runtime software
Parameterization software Standard PID control Modular PID control PID Self-Tuner Fuzzy control++
License form Single license Single license - Single license
Software class A A - -
Current version V5.1 V4.0 - -
Target system SIMATIC S7-300 SIMATIC S7-300 - SIMATIC S7-300
(CPU 313 or newer) (CPU 313 or newer), (CPU 314 or newer),
SIMATIC S7-400 SIMATIC S7-400, SIMATIC S7-400
SIMATIC C7 SIMATIC C7
Operating system - - - Windows 95 / NT
Required software package STEP 7 V5.2 or newer STEP 7 V3.1/V3.2 or - -
newer
Main memory configuration in 16 MB 16 MB - 16 MB
PG/PC
Disk storage requirement in PG/PC 1.85 MB 1.85 MB - 5 MB
Standard FBs
Required libraries Standard PID Control FBs Modular PID Control FBs PID self-tuner FBs V5.0 Fuzzy Control++ FBs
V5.1 V4.0
License forms Single license Single license - Single license
Runtime software
Parameterization software Neuro systems Loadable drivers for CP Software redundancy PRODAVE MPI
441-2 and CP 341
License form Single license Single license, copy Single license, copy Single license, copy
license license license
Software class - - - A
Current version - - - V5.6
Target system SIMATIC S7-300 SIMATIC CP 341, SIMATIC S7-300 SIMATIC S7-200
(CPU 314 or newer), SIMATIC CP 441-2 (CPU 315-2 DP only), SIMATIC S7-300
SIMATIC S7-400 SIMATIC S7-400 SIMATIC S7-400
SIMATIC C7
Operating system Windows 95/NT - - Windows 98/Me/NT/
2000 Prof./XP
Required software package - - STEP 7 V4.0 -
Main memory configuration in 16 MB - - 8 MB on PG/PC
PG/PC
Disk storage requirement in PG/PC 5 MB - - 2 MB
Standard FBs - - -
Required libraries Neuro systems FBs - - -
License forms Single license - - -
Software class - - - -
Current version - - - -
Target system SIMATIC S7-300 - - -
(CPU 314 or newer),
SIMATIC S7-400
Operating system Windows 95/NT - - -
Required software package - - - -
Main memory configuration in 16 MB on PG/PC - - -
PG/PC
Disk storage requirement in PG/PC 5 MB - - -
■ Overview
• Standard configuration software for SIMATIC Operator
Panels and for the HMI part of the SIMATIC C7
• Executable under Windows 98 SE/ME and
Windows NT 4.0/2000/XP Professional
• Current versions:
- SIMATIC ProTool/Lite V6.0 + SP2
- SIMATIC ProTool V6.0 + SP2
7
■ Ordering data Order No. Order No.
Configuration software 6AV6 581-3BX06-0CX0 Software update service
SIMATIC ProTool V6.0 + SP2 2) B)
including ProAgent V6.0 + • SIMATIC ProTool 6AV6 581-3AX00-0AX2
SP2 1) B) • SIMATIC ProTool/Lite 2) B) 6AV6 580-3AX00-0AX2
(ProAgent for OP; ProAgent/MP), Powerpack
language versions: G/E/F/I/S,
incl. native drivers on CD-ROM; • ProTool/Lite to 6AV6 571-3AB06-0CX0
electronic documentation ProTool V6.0 + SP2
(.pdf/.chm) in German, English,
French, Spanish, Italian Upgrade
on CD-ROM • ProTool/Lite to 6AV6 580-3BX06-0CX4
Configuration software 6AV6 580-3BX06-0CX0 ProTool/Lite V6.0 + SP2 B)
SIMATIC ProTool/Lite • ProTool to 6AV6 581-3BX06-0CX4
V6.0 + SP2 B) ProTool V6.0 + SP2 B)
Electronic documentation,
• German 6AV6 594-1MA06-1AA0 on CD-ROM
• English 6AV6 594-1MA06-1AB0 5 languages
(English, French, German, Italian
• French 6AV6 594-1MA06-1AC0 and Spanish);
• Italian 6AV6 594-1MA06-1AD0 Comprising: all currently available
user manuals, product manuals
• Spanish 6AV6 594-1MA06-1AE0 and communication manuals for
SIMATIC HMI
■ Overview
• PC-based HMI solution for single-user systems direct
at the machine
• SIMATIC ProTool/Pro consists of:
- SIMATIC ProTool/Pro RT runtime software for PC-based
systems
- Configuring software SIMATIC ProTool/Pro Configuration
(CS) for configuring PC-based systems as well as
SIMATIC Operator Panels
• For Windows 98 SE/ME and
Windows NT4.0/2000/XP Professional
• Current version:
- SIMATIC ProTool/Pro Configuration V6.0 + SP2
- SIMATIC ProTool/Pro Runtime V6.0 + SP2
■ Technical specifications 7
Type SIMATIC ProTool/Pro Runtime Type SIMATIC ProTool/Pro Runtime
The specifications are maximum Variables 2048 3)
values
Password protection
Operating system MS Windows 98 SE/ME • Password levels 10 (0 ... 9)
(ME not for ASIA version),
MS Windows NT 4.0/2000/ • Number of passwords 50
XP Professional Visual Basic scripts 50
Messages 4000 • Number of lines 100
• Message text 70 Online languages, max. 5
(number of characters)
Communication
• Message buffer size 1024
• Pending message events 500 SIMATIC S7 MPI interface/
PROFIBUS DP interface
Archives (number) 100 • Number of connectable partners, ProTool/Pro permits
• Archivable data Process values (max. 100), max. up to 8 connections,
messages depending on the scope of
• Max. number of entries per archive 500,000 configuration (communication)
(incl. sequential archive) SIMATIC S7 PPI interface
• Archive types Short-term archives, sequential • Number of connectable partners, 1 for ProTool/Pro
archives (max. 40 per archive) max.
• Data storage format CSV (Comma Separated Vari-
able) and interfacing to ODBC SIMATIC S5 loop-through No
database (database not included arrangement
in scope of supply) SIMATIC S5
Recipes 1000 PROFIBUS DP interface,
• Number of connectable partners, 1 for ProTool/Pro
• Entries per recipe 2000 3)
max.
• Data records 5000 2)
Diagrams 300
• Fields per diagram 400
• Variables per diagram 400
• Static text 30,000
• Graphics objects 2000
• Complex objects per picture 40
(e.g. bars)
• Trend curves 800
• Graphics lists 1) 500
• Text lists 1) 500
• Number of entries in symbol lists 3,500
1) Only 500 text and graphics lists in total.
2) Depends on the storage medium used.
3) Depends on the number of licensed PowerTags.
B)
6AV6 584-1AB06-0CX0
6AV6 584-1AC06-0CX0
on CD-ROM with license
(single license) for
D)
• 128 PowerTags (RT 128) 6AV6 584-1AB06-0CV0
B)
• 512 PowerTags (RT 512) 6AV6 584-1AD06-0CX0 D)
• 256 PowerTags (RT 256) 6AV6 584-1AC06-0CV0
B)
• 2048 PowerTags (RT 2048) 6AV6 584-1AF06-0CX0 D)
• 512 PowerTags (RT 512) 6AV6 584-1AD06-0CV0
Upgrade D)
• 2048 PowerTags (RT 2048) 6AV6 584-1AF06-0CV0
• ProTool/Pro to 6AV6 582-2BX06-0CX4
ProTool/Pro V6.0 + SP2 1) B) Communication via Industrial Ethernet
• ProTool/Pro RT to 6AV6 584-3AX06-0CX4 CP 1613 6GK1 161-3AA00
ProTool/Pro RT V6.0 + SP2 B)
PCI card (32 bits) for connecting
Powerpacks a PG/PC to Industrial Ethernet
(communications software must
SIMATIC ProTool/Pro RT be ordered separately)
PowerTags from
B) S7-1613 V6.1 D) 6GK1 716-1CB61-3AA0
• 128 to 256 PowerTags 6AV6 570-1BC00-0AX0
Software for S7 communication,
B)
• 128 to 512 PowerTags 6AV6 570-1BD00-0AX0 S5-compatible communication
B) (SEND/RECEIVE) incl. OPC,
• 128 to 2048 PowerTags 6AV6 570-1BF00-0AX0
PG/OP communication (S5/505
B) Layer 4 communication with
• 256 to 512 PowerTags 6AV6 570-1CD00-0AX0
B) TCP/IP), for Windows NT4.0 /
• 256 to 2048 PowerTags 6AV6 570-1CF00-0AX0 2000 / XP
B)
• 512 to 2048 PowerTags 6AV6 570-1DF00-0AX0 CP 1612 A) 6GK1 161-2AA00
• SIMATIC ProTool/Lite to 6AV6 571-2AC06-0CX0 PCI card (32-bit) for connecting
B)
ProTool/Pro V6.0 + SP2 a PG/PC to Industrial Ethernet
(SOFTNET-S7 must be ordered
• SIMATIC ProTool to 6AV6 571-2BC06-0CX0
separately)
ProTool/Pro V6.0 + SP2 B)
2) CP 1512 6GK1 151-2AA00
Software update service
PCMCIA card (Cardbus 32-bit)
• Software update service 6AV6 582-3AX00-0AX2 for connecting a PG/Notebook to
SIMATIC ProTool/Pro B) Industrial Ethernet (SOFTNET-S7
must be ordered separately)
SOFTNET-S7 V6.1 D) 6GK1 704-1CW61-3AA0
Software for S5-compatible
A) Subject to export regulations: AL: N and ECCN: EAR99H communication (SEND/RECEIVE)
B) Subject to export regulations: AL: N and ECCN: EAR99S and S7 communication for
D) Subject to export regulations: AL: N and ECCN: 5D992B1 Windows NT4.0 / 2000 / XP
(max. 64 connections)
1) Upgrade for Configuration Station (CS) as well as Runtime (RT) Station
2) For a period of 12 months and for a fixed price, the customer is SOFTNET-S7/Lean V6.1 D) 6GK1 704-1LW61-3AA0
automatically provided with all upgrades and service packs per installed Software for S5-compatible
ProTool/Pro package. The contract is automatically extended by a further communication (SEND/RECEIVE)
year unless canceled 12 weeks prior to expiry. and S7 communication for
3) The runtime licenses for ProAgent/PC must be purchased separately for Windows 2000 / XP
each target system (max. 8 connections)
■ Overview
• Uniform range of engineering tools for configuration of
SIMATIC HMI devices, the operating component of
SIMATIC C7 devices, the SIMOTION/SINUMERIK panel PCs,
and the PC-based visualization software WinCC flexible
Runtime
• For Windows 2000/XP Professional
• Current version:
- SIMATIC WinCC flexible 2004 Advanced
- SIMATIC WinCC flexible 2004 Standard
- SIMATIC WinCC flexible 2004 Compact
- SIMATIC WinCC flexible 2004 Micro
7
• Option for version assignment to configuration data and for
tracking of modifications to configuration (e.g. as proof in
regulated sectors)
• For the SIMATIC WinCC flexible Advanced engineering tool
• One license is necessary fo r each configuration station
■ Overview
• PC-based visualization software for single-user systems
direct at the machine
• For Windows 2000/XP Professional
• Current version:
- SIMATIC WinCC flexible 2004 Runtime with 128, 512 or
2048 PowerTags
7
■ Technical specifications
Type SIMATIC Recipes 4) 1,000
WinCC flexible Runtime
• Elements per recipe 2,000 3)
The specifications are
maximum values • Records per recipe 5,000 2)
■ Overview
New features of V6.0:
• Historian concept in the basic system with significantly
enhanced archiving performance, integrated long-term
archiving and optional evaluation functions; based on the
Microsoft SQL Server 2000
• Customized expansion capabi lity of the WinCC Graphics
Designer by means of Visual Basic for Application (VBA)
• Easy, open and rugged Runtime Scripting with Visual Basic
Scripting (VBScript)
• Expanded, uniform scalability by increasing the number of
servers (12) and clients (32) with expansion of the functionality
at the same time, and also through the possibility for use of a
central archive server
• Extended Web functionality with WinCC clients as Web
servers with access to all lower-level WinCC servers
• Further functional adaptation to the WebNavigator client on a
WinCC client
• Enhancement of the reporting and logging system thanks to
higher flexibility, greater openness and simple operation
7 • PC-based operator control and monitoring system for
visualizing and operating processes, production flows,
• Executable under Windows XP (s ingle-user station and client)
• New options:
machines and systems in all sectors - with the simple single-
user station through to distributed multi-user systems with - WinCC/Dat@Monitor (display and analysis of current
redundant servers and multi-site solutions with Web clients. process states and historical data on office PCs)
WinCC is the information hub for corporation-wide vertical - WinCC/ConnectivityPack (OPC Alarms&Events / Historical
integration. Data Access, database access via WinCC OLE-DB)
- WinCC/IndustrialDataBridge (connection of external
• The basic system configuration (WinCC basic software)
databases)
includes functions meeting industrial requirements for
- FDA options: WinCC Audit and SIMATIC Logon Services
signaling and acknowledging events, archiving of messages
and measured values, logging of all process and
configuration data, user administration and visualization.
• The WinCC basic software forms the core of a wide range of
different applications. Building on the open programming
interfaces, a wide range of WinCC options (from Siemens
A&D) and WinCC add-ons have been developed
(by Siemens-internal and external partners).
• Current versions:
- SIMATIC WinCC V6.0 SP2:
Executes under Windows 2000 / XP
- SIMATIC WinCC V5.1 SP2:
Executes under Windows NT 4.0 / 2000
■ Technical specifications
Type SIMATIC WinCC V5.1 SP1 SIMATIC WinCC V6.0 SP2
Operating system Windows NT4.0/ Windows XP Professional/
Windows 2000 Windows 2000
WebClient, additionally: WebClient/Dat@Monitor Client, additionally:
Windows 98, Windows NT4.0/
Windows ME, Windows XP Home,
Windows 2000 terminal services Windows 2000 terminal services
Hardware requirements for PC
CPU 1)
• Minimum Pentium II, 400 MHz Single-user system/server: Pentium III, 800 MHz
Central archive server: Pentium IV, 2 GHz
Client:: Pentium III, 300 MHz
WebClient/Dat@Monitor client: Pentium III, 300 MHz
• Recommended Pentium III, 400 MHz Single-user system/server: Pentium IV, 1400 MHz
Central archive server: Pentium IV, 2,5 GHz
Client: Pentium III, 800 MHz
WebClient/Dat@Monitor client: Pentium III, 800 MHz
RAM (main memory)
• Minimum >= 128/256 MB (single-user station/server),
>= 128 MB (client) 2)
Single-user system/server: 512 MB
Central archive server: 1 GB 7
Client: 256 MB
WebClient/Dat@Monitor client: 128 MB
• Recommended >= 256 MB (single-user station/server), Single-user system/server: 1 GB
>= 256 MB (client) 2) Central archive server: >= 1 GB
Client: 512 MB
WebClient/Dat@Monitor client: 256 MB
Graphics controller
• Minimum SVGA (4 MB), 800 x 600 SVGA (16 MB), 800 x 600
• Recommended XGA (8 MB), 1024 x 768 SXGA (32 MB), 1280 x 1024
Hard disk
• Minimum > 3 GB Single-user system/server: 20 GB
Client: 5 GB
WebClient/Dat@Monitor client: 5 GB
• Recommended > 3 GB Single-user system/server: 80 GB
Client: 20 GB
WebClient/Dat@Monitor client: 10 GB
• Hard disk (free disk space
for installation)
- Minimum 650 MB Server: 1 GB
Client: 700 MB
- Recommended >= 650 MB Server: > 10 GB
Client: > 1.5 GB
CD-ROM/DVD-ROM/ For software installation For software installation
diskette drive
1) An AMD system of comparable performance can also be used
2) At least 32 MB more when using online configuration
■ Overview
• Process diagnostics software for quick, selective fault diag- • A standardized diagnostics concept for various SIMATIC
nostics in plants and machines for SIMATIC S7 and components:
SIMATIC HMI Optimum interaction between STEP 7 engineering tools and
SIMATIC HMI
• Standard user interface
Process fault diagnostics with ProAgent for ProTool and WinCC flexible/ProAgent as well as the STEP 7 engineering tools
■ Technical specifications
ProAgent for OP ProAgent/MP ProAgent/PC WinCC/ProAgent WinCC flexible /
ProAgent 1)
Interfaces
• Can be used in conjunction with SIMATIC S7: SIMATIC S7: SIMATIC S7: SIMATIC S7: SIMATIC S7:
the following S7-300/S7-400 S7-300/S7-400 S7-300/S7-400, S7-300/S7-400; S7-300/S7-400;
automation equipment: WinAC WinAC WinAC
• Interface types SIMATIC S7 SIMATIC S7 SIMATIC S7 SIMATIC S7 SIMATIC S7
Protocol Suite: MPI, Protocol Suite: MPI, Protocol Suite: MPI, Protocol Suite: Protocol Suite:
PROFIBUS DP PROFIBUS DP PROFIBUS DP, MPI, PROFIBUS DP, MPI, PROFIBUS DP,
Industrial Ethernet, Industrial Ethernet, Industrial Ethernet,
TCP/IP TCP/IP TCP/IP
(V6.0 SP2 upwards)
Displays
Standard diagrams for: Standard views for
simple embedding
into the user dis-
plays,
sample project for
OP 270
• Device/resolution in OP27/320 x 240/ TP 270/OP 270, 6" PC/1024 x 768 PC/1024 x 768
pixels/representation monochrome
OP27/320 x 240/
color
MP 270B, 10" Keys/
Touch
PC/800 x 600 7
OP37/640 x 480/ MP 370, Keys/ Panel PC 670/870 Panel PC 670/870
color Touch 15”/1024 x 768, 15”/1024 x 768,
Keys/Touch Keys/Touch
TP27-6/320 x 240/ Panel PC 670/870
monochrome 12”/800 x 600,
Keys/Touch
TP27-6/320 x 240/ Panel PC 670,
color 10”/640 x 480
TP27-10/640 x 480/ Panel PC IL70 Panel PC IL70 15"
color 12"/15" Touch Touch
TP37/640 x 480/ FI45/1024 x 768 FI45/1024 x 768
color
C7-626/320 x 240/
monochrome
No. of languages for 5 (G/E/F/I/S) 5 (G/E/F/I/S) 5 (G/E/F/I/S) 3 (G/E/F) 5 (G/E/F/I/S)
online language selection
Functions
Changing the HMI diagnostics No No No WinCC/ProAgent No
data storage in RT V6.0 upwards
Unit overview diagram Yes Yes Yes Yes Yes
Message view Yes Yes Yes Yes Yes
Sequencer operating view No Yes Yes Yes Yes
Diagnostics detail view Yes Yes Yes Yes Yes
• Display Yes/yes/yes Yes/yes/yes Yes/yes/yes Yes/yes/yes Yes/yes/yes
STL/LAD/signal list
• Display with operands with OP27, C7-626, Yes Yes Yes Yes
symbol and comment TP27-6: standard
setting for symbols
Criteria analysis At time of error / At time of error / At time of error / At time of error / At time of error /
current status current status current status current status / current status
archivable
Motion view
• No. of representable OP27, C7-626, 6 6 6 6
motions TP27-6: 4;
OP37, TP27-10,
TP37: 5
• Directions of motion 2 2 2 2 2
• No. of representable 8 16 16 16 16
end positions per movement
1) WinCC flexible /ProAgent is not available until the release of Service Pack 1 of WinCC flexible 2004.
HVAC Lite Library provides users with the following features: Communication
• Future-oriented thanks to co nstant updates and expansions PROFIBUS DP as master Yes
• Modifications in line with new SIMATIC components AS-Interface as master Yes
• Use of all SIMATIC signal modules (input/output modules) PROFIBUS DP as slave Yes
• Use of the new SIMATIC S7-30 0 central controller modules SR via Ethernet (optional instead of operator
with Micro Memory Card (CPU 313 or later) FDL via PROFIBUS control and monitoring)
• Openness thanks to standardiz ed and documented interfaces S7 functions via MPI, PROFIBUS, Yes
• Expansion capability and flexib ility thanks to bit-modular Ethernet
block concept Engineering
• Safety thanks to tested quality-assured software blocks Automation software STEP 7 STL (LAD/CSF)
• Standardized software structure for easy expansion and HMI software SIMATIC ProTool/WinCC flexible/
modification WinCC
• Engineering guideline to support structured software
generation
• Predefined safety and operating philosophy
■ Ordering data Order No.
■ Overview
• External EPROM programming device
• For programming SIMATIC memory cards,
SIMATIC micro memory cards as well as SIMATIC EPROM and
EEPROM modules
• For connection to the PC via the USB interface
For further information see section 8
„SIMATIC pogramming devices“.
8/8 Accessories
8/8 External prommer
8/9 UD 700 Update Device
8/10 Trolley for Field PG and Power PG
8/11 CP 5613 A2
8/13 CP 5613 FO
8/15 CP 5614 A2
8/17 CP 5614 FO
8/19 CP 5512
8/21 CP 5611
8/23 SOFTNET for PROFIBUS
8/24 CP 1613
8/26 S7-REDCONNECT
8/27 CP 1612
8/29 CP 1512
8/31 CP 7515
8/33 SOFTNET for Industrial Ethernet
8/34 SOFTNET PN IO
8/35 OPC server for Industrial Ethernet
8/37 PN CBA OPC server
8/39 SNMP OPC server
Siemens ST 70 · 2005
SIMATIC PG
Programming devices
Programming devices
Field PG
■ Overview
• The mobile, industry-compati ble programming device with
Pentium 4, 2.2 GHz
• Used primarily for start-up, maintenance and servicing of
automation systems
• Ideal for mobile on-site use, ev en when space is at a premium
or when traveling
• Physical dimensions of a notebook PC
• Ready to use with preinstalled Engineering Software
(STEP 7 Professional, STEP 5, etc.) and integrated interfaces
– Engineering packages are released for use through
license keys and authorization
■ Technical specifications
General features Interfaces
Configuration Notebook PROFIBUS DP/MPI 12 Mbps (CP 5611-compatible)
Processor Mobile Intel Pentium 4, 2.2 GHz COM 1 25-pin Sub D, female;
incl. 512 KB 2nd level cache TTY;via I-Box
8 Main memory 512 MB;
expandable to 1 GB
Application programmer interface For memory cards, micro cards
and S5 EPROM modules
(using an adapter)
Free expansion slots PC card (PCMCIA):
1 x type III or 2 x type II Ethernet 10/100 Mbps
(CP 1411-compatible)
Graphics Unified Memory Architecture,
up to 32 MB graphics memory; USB 2.0 One high power, one low power
max. 1600 x 1200
external monitor PC card (PCMCIA) 1 x type III or 2 x type II
■ Overview
• High-performance programming workstation
• Used primarily for configuration, programming and simulation
• Ideal for use in the office as a replacement desktop PC thanks
to flexible mounting and the wireless full keyboard.
• High-end PC performance (e.g., Pentium 4, 2.2 GHz, 15" TFT
display ...) as well as expansion capability thanks to 2 PCI
slots
• Ready to use with preinstalled Engineering Software (STEP 7
Professional, STEP 5, etc.) and integrated SIMATIC interfaces
– Engineering packages are released for use through
license keys and authorization
■ Technical specifications
General features Interfaces
Configuration Mobile computer PROFIBUS DP/MPI 12 Mbps (CP 5611-compatible)
Processor Mobile Intel Pentium 4, 2.2 GHz Ethernet 10/100 Mbps
incl. 512 KB 2nd level cache (CP 1411-compatible)
Main memory 512 MB;
expandable to 1.5 GB
USB 2.0 1 high power,
1 low power
8
Graphics Unified Memory Architecture COM1 TTY for SIMATIC S5; 25-pin
(with 32 MB video memory)
for the connection of an external COM2 V.24 for SIMATIC OPs,
monitor with a resolution of up to converters, etc.; 9-pin
1600 x 1200, 75 Hz Programming interface For memory cards, micro memory
Display • 15" TFT display, cards and S5 EPROM modules
1024 x 768 resolution (using an adapter)
• 15" TFT display, LPT 1 x (Centronics); 25-pin
1400 x 1050 resolution VGA 1x
PC expansion slots 2 PCI (1 long; 1 short) Headset 1 (stereo)
PC card slots 2 PC cards (PCMCIA): Microphone 1 (stereo)
One type III or two type II
Ambient conditions
Loudspeaker 16-bit stereo
Degree of protection to EN 60529 IP30 at the front with unit closed
Pointing device Touch Pad
Vibrations Checked as per IEC 68-2-6
Operating system Windows 2000 Professional or
Windows XP Professional • Operation 10 to 58 Hz: 0.01875 mm,
58 to 500 Hz: 4.9 m/s2
Power supply Internal wide-range
power supply unit • Transport 5 to 9 Hz: 3.5 mm; 9 to 500 Hz:
9.8 m/s2
Connection to theft protection Kensington lock
Resistance to shock Checked as per
Warranty 24 months on hardware IEC 68-2-29
components
• Operation 50 m/s2, 30 ms,
Disk drives 100 shocks
Hard disk 80 GB 3.5" • Storage/transport 250 m/s2, 6 ms,
DVD-ROM/CD-RW 24/10/24-times, for using 1000 shocks
rewritable CDs or for burning CDs
DVD-ROM/DVD-R/RW optional;
2/1/8-times (DVD), 16/10/24-times
(CD-ROM), for rewritable DVDs or
for burning DVDs (multistandard)
Diskette drive 1.44 MB; 3,5"
■ Overview
• External EPROM programming device
• For programming SIMATIC memory cards, SIMATIC micro
memory cards as well as SIMATIC EPROM and EEPROM
modules
• For connection to the PC via the USB interface
■ Technical specifications
6ES7 792-0AA00-0XA0 6ES7 792-0AA00-0XA0
Power supply Dimensions and weight
• Description 90 to 264 V; • Weight, approx. 400 g
47 to 63 Hz;
8 Environmental requirements
long range power pack • Width
• Height
172 mm
40 mm
■ Overview
• The service partner for simplified program updating
• For saving programs and configuration data
■ Technical specifications
6ES7 700-0AL00-0YA0 6ES7 700-0AL00-0YA0
Supply voltages Relative humidity
Rated value - Operation, min. 5%
- 24 V DC Yes - Operation, max. 95 %; at 25°C (no condensation),
- permissible range,
lower limit (DC)
15 V
Vibration
tested to DIN IEC 68-2-3
8
- permissible range, 30 V - Operation, tested Yes; IEC 68, Part 2-6; 10 to 58 Hz;
upper limit (DC) to IEC 60068-2-6 constant amplitude 0.075 mm;
58 to 150 Hz; acceleration
Current consumption 9.8 m/s2
• Current consumption, max. 160 mA; typical 80 mA
Impact test
Interfaces - tested to IEC 60068-2-29 Yes; IEC 68, Part 2-27/29; semi-
• MPI Yes; RS 485 sinusoidal 100 m/s2 (10 g), 16 ms
EMC Degree of protection and
• Emitted interference to comply Yes; corresponds to CISPR 22 class of protection
with EN 55022, class B - IP 20 Yes; Housing
• Interference immunity on +/-2 kV - IP 65 Yes; Front
signal lines (to IEC 1000-4-4; burst)
Standards, approvals,
• Interference immunity on signal Yes certification
lines to comply with IEC 61000-4-4
• DIN/ISO 9001 Yes
Interference immunity to the • CSA approval Yes;
discharge of static electricity to standard C22.2 or 950 or
- Description +/-6 kV contact; C22.2 No. 220, Report LR81690
+/-8 kV air • Developed to comply with Yes
(to IEC 1000-4-2; ESD) IEC1131
- To comply with IEC 61000-4-2 Yes • FM approval Yes;
Environmental requirements FM standards No. 3611, Class I,
Div. 2, Group A, B, C, D
Operating temperature
• UL approval Yes; UL 1950, E11 5352; chan.
- min. 0 °C
standard C22.2 No. 950
- max. 45 °C
Dimensions and weight
Storage/transportation temperature
• Weight, approx. 250 g; without cables
- min. -20 °C
• Width 144 mm
- max. 70 °C
• Height 72 mm
• Depth 27 mm
■ Overview
• PCI card (universal key 5 V/3 .3 V) with microprocessor for
system interfacing for PCs and SIMATIC programming
devices/PC to PROFIBUS up to 12 Mbit/s
• Communication services:
- PROFIBUS DP master according to IEC 61158/EN 50170
- PG/OP communication with STEP 5 and STEP 7
- S7 communication
- S5-compatible communication (SEND/RECEIVE) on the
basis of the FDL interface
- PROFIBUS FMS according to IEC 61158/EN 50170
• Extensive diagnostic facilities for installation, commissioning
and operation of the module
• High performance through direct dual port RAM access
• Event and filter mechanism for relieving the host CPU
• Multiple protocol operation and parallel operation of
up to 4 CPs
• Implementation for motion control applications possible
through support of the equidistant mode
• The corresponding OPC Server and configuration tools are
included in the scope of supply of the respective communica-
tions software
■ Technical specifications
Data transmission rates
Interfaces
9.6 kbit/s to 12 Mbit/s Performance data:
Single protocol operation 8
• Number of connectable max. 124
• Connection to PROFIBUS 9-pin Sub-D connector DP slaves
• Connection to PG/PC PCI (32 bit; 3.3 V/5 V; • Number of parallel max. 120
universal keyed; 33/66 MHz) FDL tasks to be processed
Supply voltage (from PCI) 5 V DC ± 5% • Number of PG/OP and max. 50 1)
Power consumption from 5 V DC 0.8 A S7 connections
Power loss 4W • Number of FMS connections max. 40 2)
Perm. environmental conditions 1) For Credit = 1; PDU size ≤ 480 bytes
• Operating temperature +5 °C to +50 °C 2) For Credit = 1
■ Overview
• PCI card with microprocessor for system connection for PCs
and SIMATIC PGs/PC to the optical PROFIBUS at up to
12 Mbit/s
• Integral fiber-optic interface for direct FO connection
• Communication services:
- PROFIBUS DP masters according to IEC 61158/EN 50170
- PG/OP communication with STEP 5 and STEP 7
- S7 communication
- S5-compatible communication (SEND/RECEIVE) based on
the FDL interface
- PROFIBUS FMS acc. to IEC 61158/EN 50170
• Comprehensive diagnostics po ssibilities for installation,
start-up and operation of the module
• High performance over direct dual-port RAM access
• Event and filter mechanisms to reduce the loading on the host
CPU
• Multi-protocol mode and paralle l operation of up to 4 CPs
• Implementation in Motion Cont rol applications is possible
because a constant bus cycle time is supported
• The appropriate OPC server and configuration tools are inclu-
ded in the scope of supply of the respective communication
software
■ Technical specifications
Data transmission rates 9.6 kbit/s to 12 Mbit/s Performance data:
8
Single protocol operation
Interfaces
• Number of connectable Max. 122
• Connection to PROFIBUS 2 x duplex socket (FO) DP slaves
• Connection to PG/PC PCI (32 bit) • Number of parallel Max. 120
• External power supply (optical) Low voltage socket FDL tasks to be processed
through standard external power 3.5 mm/1.3 mm • Number of PG/OP and Max. 50 1)
supply S7 connections
Supply voltage from PCI 5 V DC +/- 5 % • Number of FMS connections Max. 40 2)
12 V DC +/- 5 %
Current consumption 1) For Credit = 1; PDU size ≤ 480 byte
• From 5 V DC 1.4 A 2) For Credit = 1
• From 12 V DC 0.3 A
Power loss 7W
Supply voltage (optional) 9 to 12 V DC
• Current consumption 0.4 A
• Power loss 3.6 to 4.8 W
Perm. environmental conditions
• Operating temperature
- Without fan +5°C to +40°C
- With fan (air flow 0.5 m/s) +5°C to +60°C
• Transport/storage temperature -40 °C to +70 °C
• Relative humidity Max. 95% at +25 °C
Design
• Module format PCI card
• Dimensions (W x H) in mm 107 x 168
• Weight Approx. 250 g
• Space required 1 x PCI slot (32 bits; 5 V)
DP master DP V0, DP V1, DP V2
Development Kit DK-5613 You can find the DK-5613 Software for FMS protocol, incl.
on the Internet at: PG/OP communication; FDL, FMS
Software Development Kit for http://www.siemens.com/ OPC server and NCM PC; single
CP 5613/CP 5614 for integration simatic-net/dk5613 license for 1 installation, runtime
in other operating system environ- software, software and electronic
ments on systems with a PCI slot manual on CD-ROM, license key
on diskette, Class A, for 32-bit
DP-5613 V6.2 D) 6GK1 713-5DB62-3AA0 Windows XP Professional,
Software for DP, incl. PG and 2003 Server, Windows 2000
FDL protocol, OPC server and Professional/Server,
NCM PC; single license for for CP 5613, CP 5613 FO,
1 installation, runtime software, CP 5614, CP 5614 FO
software and electronic manual German/English
■ Overview
• PCI card (universal key 5 V/3 .3 V) with microprocessor for
system interfacing for PCs and SIMATIC programming
devices/PC to PROFIBUS up to 12 Mbit/s
• Communication services:
- PROFIBUS DP master according to IEC 61158/EN 50170 on
a PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication
- S5-compatible communication (SEND/RECEIVE) on the
basis of the FDL interface
- PROFIBUS FMS according to IEC 61158/EN 50170
• Extensive diagnostic facilities for installation, commissioning
and operation of the module
• High performance through direct dual port RAM access
• Event and filter mechanism for relieving the host CPU
• Multiple protocol operation and pa rallel operation of up to 4 CPs
• Implementation for motion control applications possible
through support of the equidistant mode
• The corresponding OPC Server and configuration tools are
included in the scope of supply of the respective communica-
tions software
■ Technical specifications
Transmission rates
Interfaces
9.6 kbit/s to 12 Mbit/s Performance data
for mono-protocol operation 8
• Number of connectable Max. 124
• Connection to PROFIBUS DP 9-pin Sub-D socket DP slaves
(master)
• Data area of the slave interface: 244 bytes each
• Connection to PROFIBUS DP 9-pin Sub-D socket Input data, output data,
(slave) diagnostics data
• Connection to PG/PC PCI • Number of parallel Max. 120
(32-bit; 3.3 V/5 V; universal keyed; FDL tasks waiting
33/66 MHz)
• Number of PG/OP and Max. 50 1)
Supply voltage (from PCI) 5 V DC ± -5 % S7 connections
Current input from 5 V DC Approx. 0.9 A • Number of FMS connections Max. 40 2)
Power loss Approx. 4.5 W
1) For Credit = 1; PDU size ≤ 480 bytes
Perm. ambient conditions 2) For Credit = 1
• Operating temperature +5 °C to +50 °C
• Transport/storage temperature -40 °C to +70 °C
• Relative humidity Max. 85 % at + 30 °C
Construction
• Module format Short PCI card
• Dimensions (W x D) in mm 107 x 168
• Weight approx. 120 g
• Space requirements 1 x PCI slot
(32-bit; 3.3 V/5 V; universal keyed;
33/66 MHz)
DP master DP-V0, DP-V1, DP-V2
DP slave DP-V0, DP-V1
■ Overview
• PCI card with microprocessor for system connection for PCs
and SIMATIC PGs/PC to the electrical and optical PROFIBUS
at up to 12 Mbit/s
• Integral fiber-optic interface for FO direct connection; can be
operated as a DP master or DP slave as required
• Communication services:
- PROFIBUS DP master and slave interface according to
IEC 61158/ EN 50170 on a PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication
- S5-compatible communication (SEND/RECEIVE) based on
FDL
- PROFIBUS FMS acc. to IEC 61158/EN 50170
• Comprehensive diagnostics po ssibilities for installation,
start-up and operation of the module
• High performance over direct dual-port RAM access
• Event and filter mechanisms to reduce the loading on
the host CPU
• Multi-protocol mode and paralle l operation of up to 4 CPs
• Implementation in Motion Cont rol applications is possible
because a constant bus cycle time is supported
• The appropriate OPC server and configuration tools are inclu-
ded in the scope of supply of the respective communication
software
8
■ Technical specifications
Data transmission rates 9.6 kbit/s to 12 Mbit/s Performance data:
Single protocol operation
Basic interface setting
• PROFIBUS master 2 x duplex socket (FO) • Number of connectable Max. 122
DP slaves
• PROFIBUS slave 9-pin Sub-D connector
• Data area of slave interface: 244 byte each
Interfaces switchable through input data, output data,
software call diagnostics data
• PROFIBUS master 9-pin Sub-D connector
• Number of parallel Max. 120
• PROFIBUS slave 2 x duplex socket (FO) FDL tasks to be processed
• Connection to PG/PC PCI (32 bit; 5 V)
• Number of PG/OP and Max. 50 1)
• External power supply (optional) Low voltage socket S7 connections
through standard external power 3.5 mm/1.3 mm
supply • Number of FMS connections Max. 40 2)
Supply voltage (from PCI) 5 V DC +/- 5 % 1) For Credit = 1; PDU size ≤ 480 byte
12 V DC +/- 5 % 2) For Credit = 1
Current consumption
• From 5 V DC 1.6 A
• From 12 V DC 0.3 A
Power loss 8W
Supply voltage (optional) 9 to 12 V DC
external power supply
• Current consumption 0.4 A
• Power loss 3.6 to 4.8 W
Perm. environmental conditions
• Operating temperature
- Without fan +5°C to +40°C
- With fan (air flow 0.5 m/s) +5°C to +60°C
• Transport/storage temperature -40 °C to +70 °C
• Relative humidity Max. 95% at +25 °C
Design
• Module format PCI card
• Dimensions (W x H) in mm 107 x 168
• Weight Approx. 300 g
• Space required 1 x PCI slot
DP master DP V0, DP V1, DP V2
DP slave DP V0, DP V1
■ Overview
• For connecting programming devices, PCs and notebook
computers with a PC slot (CardBus 32-bit) to PROFIBUS and
the MPI of SIMATIC S7
• Communication services:
- PROFIBUS DP master Class 1 including acyclic DP
expansions with SOFTNET-DP
- PROFIBUS DP master Class 2 including acyclic DP
expansions with SOFTNET-DP
- PROFIBUS DP slave with SOFTNET-DP slave
- PG/OP communication
- S7 communication with SOFTNET-S7
- S5-compatible communication (SEND/RECEIVE based on
the FDL interface) with SOFTNET-DP or SOFTNET-S7
• PC card Type II (CardBus 32-bit); for programming device/PC
with PC card slot and notebook computers
• Can be used with:
- STEP 7 and NCM PC; (ProTool® , Micro/Win, ProTool/Pro® ,
SIMATIC PDM for PG/OP communication available soon)
- SOFTNET-S7 (for S7 communication)
- SOFTNET-DP, SOFTNET-DP slave (for DP)
• The appropriate OPC servers ar e included in the scope of
supply of the respective communication software
■ Technical specifications
Data transmission rate
Interfaces
9.6 kbit/s to 12 Mbit/s Design
• Module format PC card Typ II for CardBus
8
• Connection to PROFIBUS 9-pin Sub-D connector (32 bit)
• Connection to PG/PC PC Card Type II (CardBus 32 bit); • Dimensions (W x H x D) in mm 54 x 85 x 5
Supply voltage 3.0 V to 3.6 V DC • Weight
Current consumption Typ. 520 mA - Without adapter Approx. 30 g
- With adapter Approx. 130 g
Power loss 1.8 W
• Space required 1 x PC Card slot Type II (CardBus
Perm. environmental conditions 32 bit)
• Operating temperature +5°C to +45°C
DP master DP V0, DP V1 (with SOFTNET DP)
• Transport/storage temperature -20 °C to +60 °C
DP slave DP V0, DP V1
• Relative humidity 95% at +25 °C (with SOFTNET DP slave)
■ Overview
• For connecting the programming device or PC to PROFIBUS
and the MPI of SIMATIC S7
• Communication services:
- PROFIBUS DP master Class 1 including acyclic DP
expansions with SOFTNET-DP
- PROFIBUS DP master Class 2 including acyclic DP
expansions with SOFTNET-DP
- PROFIBUS DP slave with SOFTNET-DP slave
- PG/OP communication
- S7 communication with SOFTNET-S7
- S5-compatible communication (SEND/RECEIVE based
on the FDL interface) with SOFTNET-DP or SOFTNET-S7
• Short PCI card; for programming devices and PCs with
a PCI slot (32 bits)
• Can be used with:
- STEP 7, STEP 7-Micro/Win, ProTool, ProTool/Pro,
SIMATIC PDM (for PG/OP communication)
- COM PROFIBUS
- SOFTNET-S7 (for S7 communication)
- SOFTNET-DP, SOFTNET-DP slave (for DP)
• The appropriate OPC server and configuration tools are
included in the scope of supply of the respective communica-
tion software
■ Technical specifications
Data transmission rate 9.6 kbit/s to 12 Mbit/s Construction 8
Interfaces • Module format PCI card
• Connection to PROFIBUS 9-pin Sub-D socket • Dimensions (W x H x D) in mm 102 x 130
• Connection to PG/PC PCI (32-bit) • Weight Approx. 100 g
Power supply +5 V DC ± 5 % • Space requirements 1 x PCI slot
Current consumption 0.5 A DP master DP-V0, DP-V1 with SOFTNET-DP
Power loss 2.0 W DP slave DP-V0, DP-V1 with SOFTNET-DP
slave
Perm. ambient conditions
• Operating temperature +5 °C to +40 °C
• Transport/storage temperature -20 °C to +60 °C
• Relative humidity Max. 95% at +25 °C
G_IK10_XX_50039
■ Ordering data Order No.
S5-115U to S5-155U S7-300 with CP 342-5 S7-400 with
with CP 5431 FMS/DP or CP 343-5 CP 443-5 SOFTNET-S7 V6.2 D) 6GK1 704-5CW62-3AA0
Software for S7 communication,
incl. FDL protocol with OPC ser-
• Software for coupling PCs/programming devices and ver and NCM PC; single license
notebooks to programmable controllers for 1 installation, runtime software,
software and electronic manual
• For use in combination with CP 5511 (PCMCIA) and CP 5512 on CD-ROM, license key on
(PC-Card, 32-bit CardBus). CP 5611 (PCI) and integral diskette, Class A, for 32-bit
PROFIBUS interface of the SIMATIC PG/PC Windows 2000 Professional/Ser-
• Communication services: ver, Windows XP Professional,
- PROFIBUS DP master Class 1 and 2 with acyclic expansions
- PROFIBUS DP slave
2003 Server, for
CP 5512, CP 5611
German/English
8
- PG/OP communication
- S7 communication SOFTNET-DP V6.2 D) 6GK1 704-5DW62-3AA0
- S5-compatible communication (SEND/RECEIVE based on Software for DP protocol
the FDL interface) (MasterClass 1 and 2), incl. FDL
• The appropriate OPC servers are included in the scope of protocol with OPC server and
NCM PC; single license for
supply of the respective communication software 1 installation, runtime software,
software and electronic manual
on CD-ROM, license key on dis-
kette, Class A, for 32-bit Windows
2000 Professional/Server,
Windows XP Professional, 2003
Server, for CP 5512, CP 5611
German/English
SOFTNET-DP Slave V6.2 D) 6GK1 704-5SW62-3AA0
Software for DP slave, with DP
OPC server and NCM PC, single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, license key
on diskette, Class A, for 32-bit
Windows 2000 Professional/Ser-
ver, Windows XP Professional,
2003 Server,
for CP 5512, CP 5611
German/English
SIMATIC NET 6GK1 704-0AA00-3AA2
Software Update Service D)
For Industrial Ethernet,
PROFIBUS, OPC server, for one
year warranty incl. manuals on
CD-ROM
Requirement: SIMATIC NET
PC/Windows products
German/English
D) Subject to export regulations: AL: N and ECCN: 5D992B1
■ Overview
• PCI card with a microprocessor for connecting the PG or PC
to Industrial Ethernet with 10/100 Mbit/s Autosensing
• Communication services using
- ISO or TCP/IP transport protocol
- PG/OP communication
- S7 communication
- S5-compatible communication (SEND/RECEIVE)
• 15-pole ITP connection
• RJ45 connection
• Clock time synchronization
• ISO and TCP/IP transport protocol onboard
• SNMP-supported diagnostics
• The appropriate OPC server and configuration tools are inclu-
ded in the respective scope of supply of the communication
software
■ Technical specifications
Data transmission rate 10/100 Mbit/s autosensing Performance data
for mono-protocol operation
Interfaces
S7 and programmable device/
• Connection to Industrial Ethernet 15-pin Sub-D socket operator panel communication
8 Industrial Ethernet
■ More information
Additional information is available in the Internet under:
S7-400H S7-400H
http://www.siemens.com/simatic-net/ik-info
G_IK10_XX_10048
8 SOFTNET PN IO V6.2
Software for PROFINET I/O cont-
6GK1 704-1HW62-3AA0 including MIB compiler; single
license for 1 installation of the
roller with OPC server and NCM runtime software, software and
PC; single license for 1 installa- electronic manual on CD-ROM;
tion, runtime software, software license key on diskette, for 32-bit
and electronic manual on Windows XP Professional,
CD-ROM, license key on diskette, 2003 server, 2000 Professional
Class A, for 32-bit Windows XP WS/Server;
Professional, 2003 Server; Win- for CP 1512/CP 1612/CP 1613
dows 2000 Professional, server German/English
for CP 1512 and CP 1612, • Basic D) 6GK1 706-1NW62-3AA0
German/English Administration of up to
SOFTNET-S7 V6.2 for Industrial 6GK1 704-1CW62-3AA0 20 IP addresses
Ethernet D) • Extended D) 6GK1 706-1NX62-3AA0
Software for S7 and S5-compa- Administration of up to
tible communication, incl. OPC 200 IP addresses
server, PG/OP communication • Power Pack D) 6GK1 706-1NW62-3AA4
and NCM PC; up to 64 connec- Upgrade from SNM OPC
tions, single license for 1 installa- Server Basic to
tion, runtime software, software SNMP OPC Server Extended
and electronic manual on
CD-ROM, license key on diskette, SIMATIC NET 6GK1 704-0AA00-3AA2
Class A, for 32-bit Windows XP Software Update Service D)
Professional, 2003 Server, For Industrial Ethernet,
2000 Professional/Server; PROFIBUS, OPC server,
for CP 1512 and CP 1612 for one year service
German/English incl. manuals on CD-ROM
SOFTNET-S7 Lean V6.2 D) 6GK1 704-1LW62-3AA0 Requirement:
Software for S7 and S5-compa- SIMATIC NET PC/
tible communication, incl. OPC Windows products
server, PG/OP communication German/English
and NCM PC; up to 8 connec-
tions, single license for 1 installa- Documentation S7-CPs/NCM S7
tion, runtime software, software for Industrial Ethernet and
and electronic manual on PROFIBUS; manual package
CD-ROM, license key on diskette, for configuring C7-CPs,
Class A, for 32-bit Windows XP IE/PB Link and PC-Stations
Professional, 2003 Server, (STEP 7 V5.3)
2000 Professional/Server;
for CP 1512 and CP 1612 • German 6GK7 080-0AA01-8AA0
German/English • English 6GK7 080-0AA01-8BA0
■ Overview
• The CP 7515 is a PC card (32-bit CardBus) for operation on an
Industrial Wireless LAN (IWLAN) radio network with reliable
communication. The CP 7515 can be used in a standard
WLAN according to IEEE 802.11b/g and IEEE 802.11a at
2.4 GHz or 5 GHz.
Transmission rates up to 54 Mbps (108 Mbps in turbo mode)
with IEEE 802.11g and IEEE 802.11a.
• Two integrated antennae (for antenna diversity) for reliable
reception in areas that place high demands on radio commu-
nication
• Highly reliable thanks to reserving the data rate
(only in combination with SCALANCE W-700 Access Points)
• High degree of protection against unauthorized access
thanks to WPA and 128-bit encoding (AES)
• Integration in STEP 7/NCM PC
• Communication services using ISO or TCP/IP transport
protocols:
- PG communication
- S7 communication
- S5-compatible communication (SEND/RECEIVE)
• For use in industrial environm ents as well as in office/enter-
prise areas
• The appropriate OPC server and configuration tools are inclu-
ded in the scope of supply of the respective communication
software.
8
■ Technical specifications
Data transmission rate Wireless approvals
• IEEE 802.11b 2.412 - 2.462 GHz, • Wi-Fi Compliance Yes
depending on the national (Wireless Fidelity)
approval,
1, 2, 5.5, 11 Mbit/s • National approvals current approvals can be found
on the Internet under
• IEEE 802.11g 2.412 - 2.462 GHz,
www.siemens.com/
depending on the national
simatic-net/ik-info
approval,
1, 2, 5.5, 6, 9, 11, 12, 18, 24, 36, Power supply 3.3 V DC
48, 54 Mbit/s
Current consumption Max. 600 mA
• IEEE 802.11a 5.15 - 5.25 GHz, 5.25 - 5.35 GHz,
5.7 - 5.8 GHz, Power loss max. 2 W
depending on the national
Degree of protection IP20
approval,
6, 9 , 12, 18, 24, 36, 48, 54 Mbit/s Permissible ambient conditions
• Turbo mode Max. 108 Mbit/s • Operating temperature 0 °C to +55 °C
Interfaces • Transport/storage temperature -20 °C to +75 °C
• Connection to PG/PC/Notebook PC card Type II (32-bit CardBus) • Relative humidity in operation Max. 90 %, non-condensing
• Antennas Two integral antennae
(antenna diversity) Construction
for 2.4 GHz or 5 GHz • Module format PC card (32-bit CardBus)
Encryption • Dimensions (W x H x D) in mm 5 x 54 x 110 mm
• IEEE 802.1x Support EAP-TLS, TTLS, PEAP, WEP, • Weight 50 g
WPA with AES and TKIP
• Space requirements 1x PC Card Type II slot
Industrial wireless LAN • Reserving the data transmission
rate for clients and deterministic Software Driver software and client mana-
data communication ger for 32-bit Windows 2000 Pro-
fessional, XP Professional, 2003
• Cyclic monitoring of the radio Server
channel
Industrial Ethernet
tion, single license for 1 installa-
tion, runtime software, software
8
and electronic manual on
CD-ROM, license key on diskette,
S5-115U to -155U S7-200 S7-300 Class A, for 32-bit Windows XP
with CP 1430 TF with CP 243-1 with CP 343-1 Professional, 2003 Server,
2000 Professional/Server;
for CP 1512 and CP 1612
German/English
SOFTNET-S7 Lean V6.2 6GK1 704-1LW62-3AA0
for Industrial Ethernet D)
Software for S7 and S5-compa-
G_IK10_XX_10040
■ Overview
PC/PG
CP 1612 CP 1512
SOFTNET PN IO
Industrial Ethernet
IE/PB Link PN IO
G_IK10_XX_10073
S7-300
ET 200S
■ Overview
• The appropriate OPC servers are included in the scope of • Interfacing of OPC-capable Windows applications to
supply of the respective communication software S7-communication and S5-compatible communication
• Standardized, open, manufacturer-independent interface functions (SEND/RECEIVE), PROFINET and SNMP
• OPC Scout with browser functions as OPC client and OCX
Data Control
PC/Windows PC
COM/DCOM
DP protokol S5 compatible
S7 communication communication PROFInet protokol SNMP DX OPC server
FMS protokol (SEND/RECEIVE)
FMS-PC S7-400
8
S7-300 SIMATIC S5
(SEND/RECEIVE only)
ET 200X
Industrial Ethernet
01
S7-PC
SIMATIC S5
PROFIBUS
G_IK10_XX_10700
System integration with the OPC server
■ Technical specifications
Programming • Synchronous and asynchronous Product variants include OPC servers for:
reading and writing of variables
S7-1613 S7 communication, XML-DA
• Monitoring of variables using the S5-compatible communication
OPC server with a signal to the
client when a change occurs SOFTNET-S7 for Industrial Ethernet S7 communication, XML-DA
S5-compatible communication
• Use of quantity operations;
so a large amount of data can SOFTNET-S7 Lean for Industrial S7 communication, XML-DA
be processed in a short time. Ethernet S5-compatible communication
Interfaces • Custom Interface (C++, NET) PN CBA OPC server PROFINET CBA, XML-DA
for high OPC performance SOFTNET PN IO PROFINET IO, XML-DA
• Automation Interface SNMP OPC server SNMP protocol access
(VB, Excel, Access, Delphi, ...)
for ease-of-use DX OPC server horizontal communication
between OPC servers
• Graphics with OCX for configu-
ring instead of programming
• OPC XML-Interface
for Data Access
Protocols • S5-compatible communication
(SEND/RECEIVE)
• S7 communication
• PROFINET
■ Overview
• Access to variables in PROFIN ET CBA components over the
OPC interface ProTool/Pro Microsoft Office SIMATIC NET
OPC client OPC client OPC Scout
• Use of the objects and symbols defined using the PROFINET
engineering tool SIMATIC iMap and STEP 7
• Adding PROFINET functionality to existing installations. This
enables it to be used in parallel with other communication
protocols such as S7 communication with SOFTNET-S7 for PN CBA
S7-OPC server OPC server
Industrial Ethernet.
• OPC Scout as an OPC client with browser functions for the
variables of the PROFINET CBA components S7 PROFINET
Communication Communication
S7 Communication PROFINET
for process Communication
data Industrial Ethernet
PROFINET PROFINET
G_IK10_XX_10122
CBA CBA
Component Component
ET 200S ET 200S
8
System integration with the PN CBA OPC server
■ Technical specifications
Programming • Open and standardized Interfaces • Custom Interface (C++, .NET)
• Synchronous and asynchronous • Automation Interface
reading and writing of variables (Visual Basic, Excel, Access,...)
• Monitoring of variables using the • OPC Data Control
OPC server with a signal to the • OPC XML-Interface
client when a change occurs for Data Access
• Use of quantity operations;
so a large amount of data can Protocols • DCOM protocol
be processed in a short time. Configuring Configuring software for
PROFINET SIMATIC iMap
■ Overview
• Status monitoring and network management of
SNMP-capable devices in any OPC client systems;
e.g. SIMATIC HMI/SCADA, office application
• Easy access to SNMP-capable devices over the OPC
interface
• Devices without SNMP agents can be monitored using the
ping mechanism
• Complete integration in the SIMATIC NET OPC server
environment
• SNMP can be implemented in parallel with other communica-
tions protocols such as PROFINET or S7 communication
• Configuration and engineering is performed with
STEP 7/NCM PC, V5.2 and higher.
9/2 Introduction
9/2 Logic Control
Siemens ST 70 · 2005
SIMATIC PC-based Automation
PC-based Automation
Introduction
Logic Control
■ Overview
Siemens has developed a broad palette of perfectly interacting
hardware and software components for PC-based Automation.
The hub: SIMATIC PC-based Control with SIMATIC WinAC, the
open, flexible and reliable controller for your PC-based automa-
tion solution.
On the PC, all the tasks involved in automation, such as open-
loop and closed-loop control, operator control and visualization
and motion control can be implemented on the same platform.
Whenever PC applications have to be implemented in addition
to the classical PLC applications, PC-based Automation is the
first choice.
In addition: SIMATIC Embedded Control. The product spec-
trum of SIMATIC PC-based Automation has been expanded with
SIMATIC WinAC MP that transfers the advantages of PC-based
Automation in processing large quantities of data and demand-
ing visualization tasks to the rugged SIMATIC MP370 platform
for installation at the machine.
■ Overview
• Adds PC-based controllers to th e SIMATIC S7 controller family Properties:
• Especially suitable where a vari ety of tasks such as data pro- • Runs on standard PCs under Windows 2000 or
cessing, communication, visualization, technology and con- Windows XP Professional.
trol have to be integrated in one PC. • Code-compatible with SIMATIC S7:
Versions programmed with SIMATIC industrial software, programs can
also be used for SIMATIC S7.
• SIMATIC WinAC Software PLCs
for tasks requiring a high level of flexibility and integration • Uses standard interfaces for inte gration into the office environ-
capability. ment.
• SIMATIC WinAC Slot PLCs • Open interfaces for the integratio n of solution-specific techno-
for tasks where high operational reliability and availability are logical hardware and software.
a priority.
• SIMATIC WinAC ODK
allows PC solutions for technological tasks to be integrated
flexibly and powerfully into the controller.
■ Overview
• WinAC RTX:
- The software solution for tasks which demand hard
deterministics.
- With real-time extension to provide deterministic behavior for
the control unit.
SIMATIC WinAC software PLCs each comprise the following
components:
• Windows logic controller
• OPC server and ActiveX components
• Driver for PROFIBUS CPs
• VenturCom RTX real-time kernel (WinAC RTX only)
Optional:
• CP for connecting to PROFIBUS DP:
- CP 5611 or the integral PROFIBUS interface on the
SIMATIC PC (WinAC Basis only)
- CP 5613 A2.
• Optimized for applications th at demand high flexibility and • SIMATIC WinAC PN option
integration capability. - Permits communication between WinAC Basis and further
automation systems based on PROFINET CBA via Industrial
• SIMATIC WinAC software PLCs comprise the following products
Ethernet.
- WinAC Basis and
- WinAC RTX. • WinAC Open Development Kit (ODK):
- For using C/C++ code in WinAC Basis or WinAC RTX
• WinAC Basis:
- For integrating external software (technology programs) or
- The low-cost solution for PC-based control tasks.
PC components (e.g. scanners, PC cards for measured data
- For data-intensive processes in connection with extensive
acquisition)
PC tasks.
9 ■ Technical specifications
6ES7 671- 6ES7 671- 6ES7 671- 6ES7 671-
0CC03-0YA0 0RC04-0YA0 0CC03-0YA0 0RC04-0YA0
Memory/backup CPU/blocks (continued)
Memory Nesting depth
• Load memory - per priority class 24 24
- integral RAM, max. PC working PC main mem- - additional levels within an 24 24
memory ory can be error OB
usable used (non
paged mem- CPU/processing times
ory) • for bit instruction, min. 0.013 µs; typ. 0.013 µs; typ.
CPU/blocks
• for integer math, min. 0.025 µs; typ. 0.025 µs; typ.
DB
• for floating-point math, min. 0.025 µs; typ. 0.025 µs; typ.
- Number, max. Limited only by Limited only by
the the amount the the amount • Reference platform Pentium IV, Pentium IV,
of available of available 2.4 GHz 2.4 GHz
PC working PC working
memory memory Timers/counters and their
retentive characteristics
- Size, max. 64 KByte 64 KByte S7 counter
FB - Number 512 512
- Number, max. Limited only by Limited only by • Retentivity
the the amount the the amount
of available of available - adjustable Yes Yes
PC working PC working - lower limit 0 0
memory memory - upper limit 511 511
- Size, max. 64 KByte 64 KByte - preset 8 8
FC • Counting range
- Number, max. Limited only by Limited only by - adjustable Yes Yes
the the amount the the amount - lower limit 0 0
of available of available
PC working PC working - upper limit 999 999
memory memory
- Size, max. 64 KByte 64 KByte
OB
- Size, max. 64 KByte 64 KByte
■ Overview
• WinAC Slot 412/416:
Slot PLCs for PC-based applications demanding determinis-
tics, availability and high operational reliability.
Products
• WinAC Slot 412:
- PC-based control system as PCI board based on
CPU 412-2 PCI
- PROFIBUS DP and PROFIBUS DP/MPI interface on-board
• WinAC Slot 416:
- PC-based control system as PCI board based on
CPU 416-2 PCI
- PROFIBUS DP and PROFIBUS DP/MPI interface on-board
• PS extension board (optional)
- The PS extension board provides additional safety for the
operation of WinAC Slot 412/416 and allows operation even
if the PC fails.
- External 24 V power supply and battery backup
■ Technical specifications
6ES7 673- 6ES7 673- 6ES7 673- 6ES7 673-
2CC02-0YA0 6CC22-0YA0 2CC02-0YA0 6CC22-0YA0
Voltages and currents CPU/blocks
• Power consumption, typical 12 W 12 W DB
Current consumption - Number, max. 512 4.095
- Size, max. 64 KByte 64 KByte
• Current consumption, max. 1.5 A; Current 1.5 A; Current
consumption consumption FB
from PCI bus from PCI bus - Number, max. 256 2.048
without PS without PS
9 extension
board: 1.5 A
extension
board: 1.5 A
- Size, max.
FC
64 KByte 64 KByte
■ Overview
• SIMATIC WinAC Software PLCs and SIMATIC WinAC
Slot PLCs support powerful interfaces which allow the control
task to be closely integrated with PC-based applications.
• WinAC ODK allows users to deve lop new applications or to
integrate existing applications into the control task.
• New with WinAC ODK V4.1:
WinAC ODK V4.1 also allows the development of applications
for WinAC Slot and replaces WinAC Slot T-Kit.
■ Technical specifications
6ES7 806-1CC02-0BA0 6ES7 806-1CC02-0BA0
CPU/ programming Software requirements
Open development interfaces • Required software MS Visual Developers Studio,
- CCX (Custom Code Extension) Yes; C/C++, Unmanaged Code V6.0 >= SP 3; MS Visual Develop-
ers Studio .net 2003; VenturCom
- SMX (Shared Memory Extension) Yes; C/C++, Unmanaged Code SDK V6.0 (only for realtime appli-
- CMI (Controller Management Yes; C/C++, C#, VB cations with WinAC RTX)
Interface)
Operating system
Hardware requirements
• Required hardware PC with color monitor, keyboard,
mouse or pointing device for
- Windows NT 4.0
- Windows 2000
No
Yes; Professional, as of SP 3
9
Windows - Windows XP Yes; Professional, SP 1
• required memory on hard disk, 10 MByte Software
min.
Configuration software
• Main memory, min. 256 MByte
- Description WinAC product support: WinAC
• Processor Intel Pentium 800 MHz Basic V4.1; WinAC RTX V4.1;
WinAC Slot V3.4
■ Overview
SIMATIC Embedded Control extends the SIMATIC product
range with a class of devices for operator control at the machine
level and visualization on a single platform.
• SIMATIC WinAC MP is the soft PLC which runs under Win-
dows CE and can be installed on the multifunctional platform
MP 370. WinAC MP is the cost-optimized solution for determi-
nistic processes in conjunction with a rugged hardware
platform. At the same time it is ideal for applications in which
large amounts of data are processed.
• The SIMATIC MP 370 also provides the cost-optimized
rugged hardware platform and the visualization software.
Similar to the Operator Panels and programmable controllers,
it is constructed without a fan or hard disk and is realtime-ca-
pable and deterministic.
■ Overview
• The software PLC which runs under Windows CE and can be
installed on the multifunctional platform MP 370 12" and
MP 370 15“
• The cost-optimized solution for deterministic processes in
conjunction with a rugged hardware platform. At the same
time it is ideal for applications in which large amounts of data
are processed.
• Ideal for tasks directly at the machine when a user-friendly
user interface is extremely important or the control task
demand large programs and extensive data memory.
■ Technical specifications
SIMATIC WinAC MP V3.1 System requirements
User memory • Hardware SIMATIC MP 370 12" Touch,
MP 370 12" Key or MP 370
• Flash memory (integrated) 5 MB 15” Touch
• Working memory (integrated) 1 MB • Operating system Windows CE 3.0
• Load memory (integrated) 1 MB (included on MP 370)
• Bit memories 2 KB • PLC programming software STEP 7, Version 5.2 or higher
• Counters 512 • Visualization configuration software ProTool, Version 6.0,
• Timers 512 SP2 or higher
• Retentive data
Number of blocks
Yes, with UPS • Communication software for
Industrial Ethernet (only required
SOFTNET PG for IE
9
on the programming device)
• FB/FC/OB/DB/SDB total max. 2500 Communication functions
I/O Connections, total 24
• I/O address space each 16 KB I/O • Ethernet, max. 22
• Number of inputs/outputs each 1 KB I/O • PROFIBUS, max. 4
• Reserved OS connections 1
• Connection of the I/O PROFIBUS DP up to 12 Mbits/s
(MP 370 on board) • Reserved PG connection 1
• Number of PROFIBUS DP slaves 32 PG/OP communication Yes
Execution times Global data communication No
• Bit operations (typ.) 0.2 µs S7 basic communication No
• Mathematical operations, typ. 0.15 µs S7 communication
Technology • As server Yes
• SIMATIC FMs FM 350, FM 351, FM 352
• As client Yes
• Easy Motion Control Yes
■ Overview
• Multi panels (MPs) can be used just like the operator panels
for operating and monitoring machines on site.
• Their functional scope can be expanded by installing additio-
nal Windows CE applications (multi panel options)
• The SIMATIC MP 370 units based on Windows CE combine
the ruggedness of operator panels with the flexibility of PCs
• Pixel graphics 12.1" or 15.1" TFT display, color (256 colors)
• MP 370 12“ Keys:
38 system keys, 36 freely-configurable and freely-inscribable
function keys (36 with LEDs)
MP 370 12" and 15" Touch:
Touch screen (analog/resistive)
• All interfaces on board, e.g MPI, PROFIBUS DP, USB,
Ethernet, serial
■ Technical specifications
Type MP 370 12” Key MP 370 12" Touch MP 370 15" Touch
Display TFT liquid crystal display (LCD) TFT liquid crystal display (LCD) TFT liquid crystal display (LCD)
• Size 12.1" 12.1" 15.1"
• Resolution (W x H in pixels) 800 x 600 800 x 600 1024 x 768
• Colors 256 colors 256 colors 256 colors
• MTBF of backlighting (at 25°C) Approx. 50,000 hours Approx. 50,000 hours Approx. 50,000 hours
Control elements Membrane keyboard Touch screen Touch screen
9 • Function keys, programmable
• System keys
36 function keys, all with LEDs - -
38 (3 with LED) - -
• Numeric/alphanumeric input Yes/yes Yes/yes Yes/yes
• External mouse, keyboard, USB / USB / USB USB / USB / USB USB / USB / USB
barcode reader
Processor RISC CPU RISC CPU RISC CPU
Operating system Windows CE Windows CE Windows CE
Memory
• Type Flash / RAM Flash / RAM Flash / RAM
• Usable memory for user data 12 MB (of which 7 MB for 12 MB (of which 7 MB for 12 MB (of which 7 MB for
configuration) configuration) configuration)
Ports 1 x TTY/RS 232, 1 x RS 232, 1 x TTY/RS 232, 1 x RS 232, 1 x TTY/RS 232, 1 x RS 232,
1 x RS 422/RS 485 1 x RS 422/RS 485 1 x RS 422/RS 485
• PC card slot 1 x PC card slot 1 x PC card slot 1 x PC card slot
• CF card slot 1 x CF card slot 1 x CF card slot 1 x CF card slot
• USB (Universal Serial Bus) 1 x USB 1 x USB 1 x USB
• Ethernet 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)
Connection to PLC S5, S7-200, S7-300/400, 505, S5, S7-200, S7-300/400, 505, S5, S7-200, S7-300/400, 505,
WinAC, SINUMERIK, SIMOTION, WinAC, SINUMERIK, SIMOTION, WinAC, SINUMERIK, SIMOTION,
Allen Bradley (DF1and DH485), Allen Bradley (DF1and DH485), Allen Bradley (DF1and DH485),
Mitsubishi (FX), Mitsubishi (FX), Mitsubishi (FX),’
Telemecanique (ADJUST) 1), Telemecanique (ADJUST) 1), Telemecanique (ADJUST) 1),
Modicon (Modbus), Modicon (Modbus), Modicon (Modbus),
OMRON (Link/MultiLink), LG OMRON (Link/MultiLink), OMRON (Link/MultiLink),
GLOFA GM, LG GLOFA GM, LG GLOFA GM,
other non-Siemens PLCs other non-Siemens PLCs other non-Siemens PLCs
2) Not battery-backed
2) Not battery-backed
Siemens ST 70 · 2005 9/19
PC-based Automation
SIMATIC Embedded Control
SIMATIC MP 370
10/2 Introduction
10/2 Component based Automation
10/3 Software
10/3 SIMATIC iMap
10/4 PN CBA OPC server
10/5 SIMATIC ProTool/Pro
Sec.7 1) SIMATIC WinCC flexible
10/19 Gateways
10/19 IE/PB Link
Siemens ST 70 · 2005
Component based Automation
■ Overview ■ Design
A configuration with Component based Automation comprises a
number of components:
• Bus systems:
- Industrial Ethernet (obligatory)
- PROFIBUS, e.g. for real-time tasks (optional)
• Industrial Ethernet stations
• PROFIBUS stations
Industrial Ethernet stations require PROFINET communication
mechanisms. The following Ethernet devices and software
products are available:
• SIMATIC WinAC PN PC-based Control with software PLC
• PROFINET-compatible CP 343-1 PN
for connecting the S7-300 to Ethernet
• PROFINET OPC server for acce ss to data on PROFINET
devices from PC applications and visualization systems
• Visualization via OPC:
Any visualization product that can function as an OPC client
• Automation concept for implementing applications with can be used, e.g. SIMATIC ProTool/Pro, SIMATIC WinCC,
"distributed intelligence" third-party HMI. SIMATIC iMap features specific integration of
SIMATIC ProTool/Pro.
• Simple data exchange betw een intelligent devices makes
modularization of machines and plants easy PROFIBUS segments are connected to Industrial Ethernet via a
• Central, plant-wide enginee ring makes communication PROFINET proxy. These devices operate as masters on
configuration easy PROFIBUS. They are available as:
• Integration of Ethernet and fieldbus • SIMATIC WinAC PN PC-based Control with software PLC
• Support of vertical integrat ion thanks to the use of IT • SIMATIC NET IE/PB Link,
standards in automation compact gateway between Industrial Ethernet and PROFIBUS
• Use of the Ethernet standa rd PROFINET specified by The following can be used as PROFIBUS nodes:
PROFIBUS International (PI): • SIMATIC ET 200X and ET 200S with separate CPU as
Problem-free integration of standard-compliant devices from intelligent field devices on PROFIBUS
various manufacturers
• SIMATIC S7-300 CPUs with integrated PROFIBUS DP
interface as intelligent slaves on PROFIBUS,
e.g., compact CPUs CPU 313C-2 DP and CPU 314-2 DP
10 • All current standard slaves
with GSD file to PROFIBUS DP standard
Even existing system sections networked with PROFIBUS can
be integrated into Component based Automation systems.
For this purpose, an Industrial Ethernet interface with PROFINET
function must be added to the PROFIBUS master.
• For simple graphic configuring of communication between Software update service 6ES7 820-0CC01-0YX2
system modules and machine-machine on the production line Upgrade to V2.0, single license 6ES7 820-0CC03-0YX4
• Open for PROFINET devices from different vendors on Indus-
trial Ethernet
• Runs on Windows 2000 and Windows XP
10
• Adding PROFINET functionality to existing installations. PN CBA OPC server V6.2 D) 6GK1 706-0HB62-3AA0
This enables it to be used in parallel with other communication PROFINET OPC server for CBA;
protocols such as S7 communication with SOFTNET-S7 for single license for 1 installation,
Industrial Ethernet. runtime software, software
• OPC Scout as an OPC client with browser functions for the and electronic manual on
CD-ROM, license key on diskette,
variables of the PROFINET CBA components Class A, for 32-bit Windows XP
Professional,
2000 Professional/Server; for
ProTool/Pro Microsoft Office SIMATIC NET CP 1512 and CP 1612
OPC client OPC client OPC Scout German/English
Software iMap V2.0
for configuring
PROFINET CBA,
PN CBA Prerequisite:
S7-OPC server OPC server
Windows 2000 Prof. SP4 or
Windows XP Prof. SP1;
on PG or PC with Pentium
S7 PROFINET processor, min. 500 MHz;
Communication Communication STEP 7, V5.2 SP 1 and higher
S7 Communication PROFINET incl. NCM, SIMATIC NET IE SOFT-
for process Communication NET-PG, V6.2 and higher;
data Industrial Ethernet PN OPC server, V6.2 and higher
Type of delivery:
German, English with electronic
PROFINET documentation;
IE/PB PROFINET
CBA Link PN CBA CBA • Single license 6ES7 820-0CC03-0YX0
Component as proxy Component
• Software update service 6ES7 820-0CC01-0YX2
e.g. S7-400 with e.g. S7-300 with CP 343-1
CP 443-1 Advanced • Upgrade iMap V2.0 6ES7 820-0CC03-0YX4
single license
PROFIBUS DP
SIMATIC NET 6GK1 704-0AA00-3AA2
Software Update Service D)
PROFINET PROFINET
10 For Industrial Ethernet,
G_IK10_XX_10122
CBA CBA
PROFIBUS, OPC server,
Component Component
for one year service incl. manuals
ET 200S ET 200S on CD-ROM; prerequisite:
SIMATIC NET PC/Windows
products German/English
System integration with the PN CBA OPC server
D) Subject to export regulations: AL: N and ECCN: 5D992B1
• PC-based HMI solution for single-user systems direct at the SIMATIC ProTool/Pro Runtime
V6.0 + SP2 for PC systems
machine incl. ProAgent V6.0 + SP2 3)
• SIMATIC ProTool/Pro consists of:
on CD-ROM with license
- SIMATIC ProTool/Pro RT runtime software for PC-based (single license) for
systems
B)
- Configuring software SIMATIC ProTool/Pro Configuration • 128 PowerTags (RT 128) 6AV6 584-1AB06-0CX0
(CS) for configuring PC-based systems as well as SIMATIC • 256 PowerTags (RT 256) B) 6AV6 584-1AC06-0CX0
Operator Panels B)
• 512 PowerTags (RT 512) 6AV6 584-1AD06-0CX0
• For Windows 98 SE/ME and B)
Windows NT4.0/2000/XP Professional • 2048 PowerTags (RT 2048) 6AV6 584-1AF06-0CX0
• Current version: Upgrade
- SIMATIC ProTool/Pro Configuration V6.0 + SP2 • ProTool/Pro to 6AV6 582-2BX06-0CX4
- SIMATIC ProTool/Pro Runtime V6.0 + SP2 ProTool/Pro V6.0 + SP2 1) B)
• ProTool/Pro RT to 6AV6 584-3AX06-0CX4
ProTool/Pro RT V6.0 + SP2 B) 10
Powerpacks
SIMATIC ProTool/Pro RT
PowerTags from
B)
• 128 to 256 PowerTags 6AV6 570-1BC00-0AX0
B)
• 128 to 512 PowerTags 6AV6 570-1BD00-0AX0
B)
• 128 to 2048 PowerTags 6AV6 570-1BF00-0AX0
• 256 to 512 PowerTags B) 6AV6 570-1CD00-0AX0
B)
• 256 to 2048 PowerTags 6AV6 570-1CF00-0AX0
• 512 to 2048 PowerTags B) 6AV6 570-1DF00-0AX0
• SIMATIC ProTool/Lite to 6AV6 571-2AC06-0CX0
ProTool/Pro V6.0 + SP2 B)
• SIMATIC ProTool to 6AV6 571-2BC06-0CX0
ProTool/Pro V6.0 + SP2 B)
2)
Software update service
• Software Update Service 6AV6 582-3AX00-0AX2
SIMATIC ProTool/Pro B)
B) Subject to export regulations: AL: N and ECCN: EAR99S
1) Upgrade for Configuration Station (CS) as well as Runtime (RT) Station
2) For a period of 12 months and for a fixed price, the customer is automati-
cally provided with all upgrades and service packs per installed
ProTool/Pro package. The contract is automatically extended by a further
year unless canceled 12 weeks prior to expiry.
3) The runtime licenses for ProAgent/PC must be purchased separately for
each target system
PCI card (32 bits) for connecting PC/MPI adapter 6ES7 972-0CA23-0XA0
a PG/PC to Industrial Ethernet RS 232, 9-pin; male with
(communications software must RS 232/MPI converter,
be ordered separately) max. 19.2 Kbit/s
10 S7-1613 V6.1 D)
Software for S7 communication,
6GK1 716-1CB61-3AA0 A) Subject to export regulations: AL: N and ECCN: EAR99H
D) Subject to export regulations: AL: N and ECCN: 5D992B1
S5-compatible communication 1) Upgrade for Configuration Station (CS) as well as Runtime (RT) Station
(SEND/RECEIVE) incl. OPC,
PG/OP communication (S5/505 2) For a period of 12 months and for a fixed price, the customer is automati-
Layer 4 communication with cally provided with all upgrades and service packs per installed
TCP/IP), for Windows NT4.0 / ProTool/Pro package. The contract is automatically extended by a further
2000 / XP year unless canceled 12 weeks prior to expiry.
3) The runtime licenses for ProAgent/PC must be purchased separately for
CP 1612 A) 6GK1 161-2AA00 each target system
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet
(SOFTNET-S7 must be ordered
separately)
CP 1512 6GK1 151-2AA00
PCMCIA card (Cardbus 32-bit)
for connecting a PG/Notebook to
Industrial Ethernet (SOFTNET-S7
must be ordered separately)
D)
SOFTNET-S7 V6.1 6GK1 704-1CW61-3AA0
Software for S5-compatible
communication (SEND/RECEIVE)
and S7 communication for
Windows NT4.0 / 2000 / XP
(max. 64 connections)
D)
SOFTNET-S7/Lean V6.1 6GK1 704-1LW61-3AA0
Software for S5-compatible
communication (SEND/RECEIVE)
and S7 communication for
Windows 2000 / XP
(max. 8 connections)
10
• The compact CPU with integrated digital and analog I/Os and • The CPU with medium to large program memory and quantity
PROFIBUS DP master/slave interface framework for the use, if required, of SIMATIC Engineering
• With process-related functions Tools
• For tasks with special functions • High processing performance in binary and floating-point
arithmetic
• For the connection of standalone I/O devices
• PROFIBUS DP master/slave interface
Micro memory card required to operate the CPU. • For extensive I/O configurations
• For setting up distributed I/O structures
Micro memory card required for operation of CPU.
10
• The compact CPU with integrated digital and analog I/Os and • The CPU with a large program memory and PROFIBUS DP
PROFIBUS DP master/slave interface master/slave interface
• With process-related functions • For extensive I/O configurations
• For tasks with special functions • For setting up distributed I/O structures
• For the connection of standalone I/O devices
Micro memory card required to operate the CPU.
■ Technical specifications
See section 4.
■ Overview
• Interface module with integr ated CPU for SIMATIC ET 200S
• For high-performance control solutions in ET 200S
• Enhances the effective system availability of plants and
machines
• Programming through PROFIBUS DP
• Features the new SIMATIC Micro Memory Card (MMC)
• Maintenance-free because no battery
• Integrated 12 Mbit/s PROFIBUS DP slave/MPI interface for
Cu conductors
• Integrated CPU based on the CPU S7-314
• IM 151-7 CPU FO available
• Failsafe IM 151-7 F-CPU PROFIsafe available
■ Technical specifications
MLFB 6ES7151-7AA10- . . . . Data areas and their retentivity
Associated programming package STEP 7 V 5.1 + SP 6 and higher Total retentive data area all
Optional: (incl. flags; timers; counters)
• S7-SCL Bit memories 256 byte
• S7-GRAPH • Retentivity Yes
• STEP 7 V5.2 + SP1 and higher • Preset retentivity MB0 to MB15
• Master functionality Clock memory 8 (1 memory byte)
(with master interface
Data blocks
6ES7 138-4HA00-0AB0)
• Number 511
Memory
Working memory • Size 16 kbyte
• Integrated 48 kByte Local data for each 510 byte
• Expandable No priority class, max.
• Transfer memory 244 Byte I/244 Byte O External PROM programmer 6ES7 792-0AA00-0XA0
• Address area, max. 32 with max. 32 byte each For e.g. MMC with USB interface
• DPV1 No PG On request
■ Overview
• Basic modules for exchanging preprocessed I/O data
between an ET 200X and a higher level master through
PROFIBUS DP
• Two versions:
- BM147-1 with DP slave functionality and
- BM147-2 with additional DP master functionality
• CPU for PLC functionality equivalent to S7-314, in other words,
distributed intelligence for preprocessing
• For reducing the overhead on the central PLC and PROFIBUS
• With greatly reduced response ti mes to critical signals locally
• Standalone operation, for example it is still possible to operate
even if the DP master fails
• Fast, simple and integrated programming of a system with
modular programs through STEP 7
■ Technical specifications
BM147-1 and BM 147-2 CPU BM147-1 and BM 147-2 CPU
Dimensions W x H x D (in mm) Data areas and their retentivity
• Individual device 175 x 110 x 86 Total retentive data area all
(incl. flags; timers; counters)
MLFB 6ES7 147-2AA00-0XB0
(BM 147-2) Bit memories 256 byte
6ES7 147-1AA10-0XB0 • Retentivity Yes
(BM 147-1)
• Preset retentivity MB0 to MB15
Associated programming package STEP 7 V5.2 + SP1
Clock memory 8 (1 memory byte)
Memory
Data blocks
Working memory
• Number 511
• Integrated 48 kByte
• Size 16 kByte
• Expandable No
10 Load memory Plug-in through MMC (max. 8 MB)
Local data for each priority class,
max.
510
• Number of variables
DB, timers, counters
30
Number of connections
• MPI
12
Yes
10
- Of which status variables 30 • PROFIBUS DP DP slave active/passive
- Of which modify variables 14 • Point-to-point coupling No
Forcing Yes MPI mode
• Variable Inputs/outputs Utilities
• Number of variables, max. 10
• PG/OP communication Yes
Status module Yes
• Routing (BM 147-2 only) Yes
Single step Yes
• Global data communication Yes
Breakpoint 2
• S7 standard communication Yes
Diagnostic buffer Yes
• S7 communication Yes
• Number of entries 100
- As a server Yes
not adjustable), max.
• Transmission rates Max. 12 Mbit/s
Communication functions
DP slave mode
PG/OP communication Yes
Utilities
Global data communication Yes
• PG/OP communication Yes
• Number of GD packages, max. 4
• Routing (BM 147-2 only) Yes (server only)
- Transmitter, max. 4
• Global data communication No
- Receiver, max. 4
• S7 standard communication No
• Size of GD packages, max. 22 byte
• S7 communication No
- Of which consistent 22 byte
• Transmission rates Up to 12 Mbaud
S7 basic communication Yes
• Transfer memory 244 byte I/244 byte O
• Useful data per request, max. 76 byte
• Address area, max. Max.1 KB I/1 KB O
- Of which consistent 76 byte
(for X_SEND or X_RCV) • DPV1 No
64 byte
(for X_PUT or X_GET as a server)
10 converter
Fixing screws 6ES7 194-1KC00-0XA0
M5 x 20, 1 package = 100 parts
Connecting cable 6ES7 901-4BD00-0XA0
for PROFIBUS
12 Mbaud, for PG connection to
PROFIBUS DP, assembled with
2 x 9-pin Sub-D connector, 3.0 m
ECOFAST hybrid cable
Assembled with ECOFAST
connector plugs
• 1.5 6XV1 830-7BH15
• 3.0 6XV1 830-7BH30
• 5.0 6XV1 830-7BH50
• 10.0 6XV1 830-7BN10
• 15.0 6XV1 830-7BN15
ECOFAST terminating resistor
• Ordering quantity 1 part 6GK1 905-0DA10
• Ordering quantity 5 parts 6GK1 905-0DA00
ECOFAST plug connector, 6GK1 905-0CA00
can be prepared
Male contacts;
ordering quantity 5 parts
ECOFAST plug connector, 6GK1 905-0CB00
can be prepared
Female contacts;
ordering quantity 5 parts
MMC memory cards up to 8 MB
(as for S7-314)
A) Subject to export regulations: AL: N and ECCN: EAR99H
■ Overview
• Compact network transition be tween Industrial Ethernet and
PROFIBUS
• Connection to Industrial Ethernet at 10/100 Mbit/s full/half
duplex with autosensing for automatic switchover
• Connection to PROFIBUS with transmission speeds of
9.6 kbit/s to 12 Mbit/s incl. 45.45 kbit/s for PROFIBUS PA
• PROFINET standard Version V1.0
• The IE/PB link supports the PROFINET communications ser-
vices for data exchange between PROFINET devices and is
proxy for PROFIBUS field devices
• PROFINET defines an engineerin g model for distributed auto-
mation solutions and a model for system-wide communication
through PROFIBUS and Industrial Ethernet with IT standards
• Cross-network PG/OP communication through S7 routing, i.e.
all S7 stations can be remotely programmed on Industrial
Ethernet or PROFIBUS using the PG
■ Technical specifications
Data transmission rates Power loss Approx. 10 W
• Industrial Ethernet 10/100 Mbit/s autosensing Permissible ambient conditions
• PROFIBUS 9.6 kbit/s to 12 Mbit/s including • Operating temperature 0 °C to + 60 °C
45.45 kbit/s (PROFIBUS PA)
• Transport/storage temperature - 40 °C to + 70 °C
Interfaces • Relative humidity, max. 95 % at + 25 °C
• Connection to Industrial Ethernet
Design
- AUI (10 Mbit/s) 15-pin Sub-D connector
• Module format S7-300 design
- 10BaseT/100BaseT RJ45
• Dimensions (W x H x D) in mm 80 x 125 x 120
• Connection to PROFIBUS 9-pin Sub-D connector • Weight Approx. 600 g
• Connection for power supply 4-pin terminal block
Degree of protection IP20
Supply voltage 24 V DC (+/- 5%)
Configuration
Current consumption • Configuring software for PROFINET Option package SIMATIC iMAP
(at rated voltage)
• Externally from 24 V DC, max. 600 mA
• Configuring software for additional
services
NCM S7 in STEP 7 Version V5.1
SP2 and higher 10
■ Ordering data Order No. Order No.
IE/PB Link 6GK1 411-5AA00 Manual for PROFIBUS networks
Network transition between Paper version
Industrial Ethernet and PROFIBUS Network architecture, project
including electrical manual on management, network compon-
CD-ROM ents, mounting
German, English, French,
Spanish, Italian • German 6GK1 970-5CA20-0AA0
10
Siemens ST 70 · 2005
Overview
SIMATIC DP
General
■ Overview
Master
PROFIBUS DP
ET 200
R eco ET 200L ET 200B ET 200X ET 200S ET 200M
0 1
Isolating transformer
ET 200iSP
*) *) *)
Multifunctional, intelligent
I/O systems
■ Overview
• Independent wiring enables pr ewiring without the electronics
connected.
• Optimized for integration into I&C systems such as SIMATIC
PCS 7 and others.
• Connection of:
- HART process devices
- EEx i valves
• Connection to PROFIBUS DP via isolating transformers.
• Baud rate 1.5 Mbps.
• Module replacement during operation (hot swapping).
• Channel-specific diagnostics for high availability.
• Screw/spring-loaded terminal connections.
• Approvals:
- CENELEC 94/9/EG
- CE
Further information
• Intrinsically-safe distributed I/ O device for use in hazardous
areas (Zones 1, 2, 21 and 22) with IP30 degree of protection. • Catalogs IK PI, CA 01
• Sensors and actuators can also be located in Zone 0 or 20. • Internet:
http://www.siemens.com/simatic-dp
• Modular design for adaptation to the automation task in hand.
SIMATIC ET 200S
■ Overview
• Use of digital and analog I/O modules, technology modules,
motor starters and frequency converters.
• Use as mini PLC on PROFIBUS DP when the integrated CPU
is used.
• Module replacement during operation
(hot swapping).
• Channel-specific diagnostics for high availability.
• Can be supplied with integrated fiber optic interface if requi-
red.
11
• Can be supplied with PROFINET interface for direct connec-
tion to Industrial Ethernet.
• Baud rate 12 Mbps.
• FAST CONNECT thanks to insu lation-piercing quick-connect
terminals.
• Ex approval for Zone 2/22.
• Permanent wiring.
• Integration of safety technology:
- Failsafe digital modules
- Failsafe motor starters
- Failsafe frequency converters
Further information
• Catalogs IK PI, CA 01
• Particularly compact distributed I/O system with IP20 degree • Internet:
of protection, which requires little wiring. http://www.siemens.com/simatic-dp
• Bit-modular design for exact ad aptation to the automation task
in hand.
■ Overview
• Compact, cost-effective
I/O devices for processing digital signals.
• Design without control cabinet with IP65/67 degree of protec-
tion with flexible and fast connections.
• Comprises a basic module and various connection blocks for
application-specific implementation options:
- ECOFAST
- M12
• Connection block contains T-fu nctionality for PROFIBUS DP
and power supply so that during commissioning and service,
the modules can be disconnected from and reconnected to
the PROFIBUS without interruption.
• Digital input/output modules, also failsafe.
Further information
• Catalogs IK PI, CA 01
• Internet:
http://www.siemens.com/simatic-dp
SIMATIC ET 200X
■ Overview
• Use of digital and analog input or output modules, motor star-
ters, frequency converters, pneumatic components and inte-
grated CPU.
• Connection of AS-Interface slaves.
• DESINA-compliant modules available (parameterizable I/O).
• Can be supplied with integrated fiber optic interface if requi-
red.
• Baud rate 12 Mbps.
• Basic module with ECOFAST connection (RS 485, FO).
• MOBY expansion modules available.
11 Further information
• Catalogs IK PI, CA 01
• Internet:
http://www.siemens.com/simatic-dp
■ Overview
• Distributed I/O with IP65 degree of protection, specifically for
robot applications.
• Aluminum die-cast housing.
• Integrated repeater.
• Parameterizable inputs/outputs: 8DI/8DO to 16DI.
• Terminal strip on rear for the connection of analog signals for
welding transformers.
• Connection via hybrid line to 17-pin M23 connector.
Further information
• Catalogs IK PI, CA 01
• Internet:
http://www.siemens.com/simatic-dp
SIMATIC ET 200L
■ Overview
• Small, cost-effective I/O device with IP20 degree of protection
for the lower performance range.
• Comprises a terminal block and an electronics block.
• Available in 2 versions:
- ET 200L block I/O (cannot be expanded).
- ET 200L-SC modular I/O, can be expanded with a
SIMATIC Smart Connect (SC) TB 16 SC terminal block.
This block supports the addition of up to 16 digital and analog
input/output channels for high modularity.
• Baud rate 1.5 Mbps.
Further information
• Catalogs IK PI, CA 01
• Internet:
11
http://www.siemens.com/simatic-dp
■ Overview
• Can be expanded with S7-300 automation system signal and
function modules (incl. failsafe modules).
• Compatible Ex analog input and output modules with HART
optimize the ET 200M for use in process engineering.
• Can be used in redundant and safety-related systems
(S7-400H, S7-400F/FH).
• Can be used in hazardous areas, Zone 2/22.
• Comprises a PROFIBUS DP inte rface with IM 153, up to 8
S7-300 I/O modules (set up with bus connectors or active bus
modules) and, if applicable, a power supply unit.
• Modules can be replaced duri ng operation with active bus
modules.
• Can be supplied with integrated fiber optic interface if requi-
red.
• Baud rate 12 Mbps.
Further information
• Catalogs IK PI, CA 01
• Modular I/O device with IP20 de gree of protection, particularly
suitable for individual and complex automation tasks. • Internet:
http://www.siemens.com/simatic-dp
SIMATIC ET 200B
■ Overview
• Small, compact I/O device with low mounting depth and IP20
degree of protection. It can be installed in even the smallest of
spaces.
• Comprises a terminal block and an electronics block with in-
tegrated PROFIBUS DP interface.
• Numerous analog and digital electronics blocks are available.
• Baud rate up to 12 Mbps.
11 Further information
• Catalogs IK PI, CA 01
• Internet:
http://www.siemens.com/simatic-dp
■ Overview
PROFINET – The open standard for automation Network components for Industrial Ethernet –
optimized for use with PROFINET
PROFINET is the innovative and open Industrial Ethernet
standard (IEC 61158) for industrial automation. With PROFINET, Active network components
devices can be linked up from the field level through to the
management level. The industrial switches of the SCALANCE X product family are
optimized for use at the field level through:
PROFINET enables system-wide communication, supports • A cost-optimized number of op tical and electrical interfaces
plant-wide engineering and uses the IT standards right down to
the field level. Solutions for implementation in process automa- • Seamless integration into the PROFINET diagnostics concept
tion are currently under development. PROFINET is already well- • Optimized support of RT technology through prioritizing.
proven in the automobile industry, food, beverages and tobacco • Integral retaining collars for stress relief and bending stress
industries and in logistics in a wide range of different applica- relief of the plug-in connection
tions. Existing fieldbus systems such as PROFIBUS can be
easily integrated without any modification of existing devices. Wireless transmission is also no problem for PROFINET with the
SCALANCE W Industrial Wireless LAN components
PROFINET is a comprehensive standard that meets all the
requirements for using Ethernet in automation. Passive network components
With the fast installation system Industrial Ethernet FastConnect
(IE FC) from SIMATIC NET, structured cabling from the office
environment becomes industry-compatible for installation in the
production hall. FastConnect cables can also be assembled
extremely quickly and easily on site. FastConnect offers a com-
plete system. Apart from the FastConnect system that is based
on copper cables – with a wide range of industrial installation
cables, socket outlets, connectors and patch cables – a com-
prehensive range of optical transmission media is also available.
Industrial Security – the security solution
specially designed for industrial automation technology; the
SCALANCE S product family is offered for this purpose including
SOFTNET Security; in the form of a software module or a hard-
ware module.
PROFINET technology components
The openness of this standard is emphasized by the marketing
of PROFINET technology. It is offered in the form development
kits as is the case for PROFIBUS. Device manufacturers are sup-
ported with implementation by worldwide competence centers.
11
■ Overview (continued)
PROFINET: distributed field devices to Industrial Ethernet
With PROFINET, distributed field devices (so-called IO devices, • CP 343-1;
e.g. signal modules) can be directly connected to Industrial communications processor for connecting the S7-300 to
Ethernet. During configuration with STEP 7, these field devices Industrial Ethernet, to connect field devices as IO devices
are assigned to a central controller (so-called IO Controller). • CP 343-1 Advanced;
Existing modules or devices can continue to be used with communications processor with integral Web server for con-
PROFINET-capable interfaces or links, thus safeguarding the necting the S7-300 to Industrial Ethernet and to connect field
investment of PROFIBUS users. devices as IO devices
An IO Supervisor is used for HMI and diagnostic functions, as for
PROFIBUS, using hierarchic diagnostic screens (overview and • CP 443-1 Advanced;
detailed diagnostics). communications processor with integral Web server and inte-
gral switch for connecting the S7-400 to Industrial Ethernet and
The following SIMATIC products are available for PROFINET for to connect field devices as IO devices
integrating distributed field devices: • CP 1616;
• IM 151-3 PN; communications processor with integral switch for connecting
interface module for direct connection of the ET 200S as an programmable controllers and PCs to Industrial Ethernet to
IO device connect field devices as IO devices
• CPU 317-2 PN/DP; • VS 130-2;
CPU module as an IO Controller for processing the process vision sensor as IO device for reading 2D code
signals and for directly connecting field devices to Industrial • SOFTNET PN IO;
Ethernet communications software that makes it possible to operate a
• IE/PB Link PN IO; PG or PC as an IO Controller
PROFINET proxy for transparent interfacing of existing • STEP 7;
PROFIBUS devices as IO devices for configuring in the tried and tested PROFIBUS manner
• IWLAN/PB Link PN IO;
PROFINET proxy for wireless, transparent interfacing of exist-
ing PROFIBUS devices as IO devices
Control PG/PC
- Configuration IO controller supervisor
- Process data
- Diagnostics
Industrial Ethernet
11
ET 200S IE/PB
- Parameterization Link
- Diagnostics PN IO
- Status/control
ET 200M
G_IK10_XX_30103
VS 130-2
Field devices
IO devices PROFIBUS
■ Overview (continued)
PROFINET: Modularization and distributed intelligence
PROFINET supports distributed automation on the basis of • CPU 317-2 PN/DP;
Component based Automation - the modular solution for central module within a CBA component that allows data to be
machine and plant construction within the context of Totally exchanged with other components over PROFINET and with
Integrated Automation. Alongside PROFINET, PROFIBUS is also the proxy over PROFIBUS
integrated into this solution. • CP 343-1;
PROFINET defines the engineering model (design and con- communications processor that makes it possible to integrate
struction of the PROFINET components) and communication an existing S7-300 into a component-based automation
between components. application
With STEP 7, reusable, intelligent technology modules are cre- • CP 443-1 Advanced;
ated including the definition of their interfaces for exchanging communications processor with integrated Web server and
data with other modules. SIMATIC iMap is used for configuration integral switch that makes it possible to integrate an existing
of the complete system by graphically linking the individual S7-400 into a component-based automation application
modules as well as simple diagnostics. • WinAC PN;
the software PLC based on WinAC. WinAC PN acts as a proxy
The following SIMATIC products are available for PROFINET and for PROFIBUS devices
distributed intelligence:
• PN CBA OPC-Server;
• IE/PB Link PN CBA; provides access to data of PROFINET CBA components
CBA proxy for integrating existing PROFIBUS devices in a directly from PC applications
component-based automation application.
The IE/PB Link PN CBA also offers S7 and dataset routing
STEP 7 FB FB
conveyor raise STEP 7:
LAD belt platform Configure devices, create
forwards user program
11
conveyor belt raise platform
PROFINET engineering
tool SIMATIC iMap,
graphical linking of
components
■ Overview
• Implementation of direct device connections over distances of
up to 100 m with Industrial Ethernet FC installation cable 2 x 2
without patching
• Easy connection (insulation disp lacement contacts) for 4-core
Twisted Pair installation cables (100 Mbit/s) without the need
for special tools
• Failsafe connection technique thanks to visible connection
area as well as color-coded blade terminals
• Industry-compatible design (ru gged metal housing, no easily
lost small parts)
• Excellent EMC shielding and deflection (metal housing)
• Integrated strain-relief for installation cables
• Compatible to the EN 50173 (RJ45)
• Additional strain and bending relief of plug-in connection
possible by latching connector to device housing, e.g. for
SCALANCE X, SCALANCE S, ET 200S.
IE FC Cable 2x2
■ Overview
• For structured cabling in the fa ctory hall; specially designed for
fast assembly
• Easy stripping with the FastCo nnect Stripping Tool; the outer
sheath and the braided shield are stripped accurately in one
step
• Connection to FastConnect products using insulation
11 displacement
• Exceeds Category 5 (Cat5e) of the international cabling
standards ISO/IEC 11801 and EN 50173
• PROFINET-compatible
• UL approval and China Compulsory Certificate (ccc)
• Different variants for different applications
- IE FC Standard Cable
- IE FC Flexible Cable
- IE FC Trailing Cable
- IE FC Torsion Cable
- IE FC Marine Cable
• High interference immunity thanks to double shielding
• Easy length measurement thanks to printed meter markings
■ Overview
• Simple connection technology (insulation displacement
contacts) for 8-core Industrial Ethernet FC twisted pair
installation cables (Cat6)
• Safe connection technology than ks to visible connection area
• Industry-standard design
- robust metal housing
- Dust covers
• Wall and DIN rail mounting inside or outside control cubicles
thanks to IP40 protection
• Good electromagnetic shielding and conduction due to metal
housing
• Integral strain relief for 8-core installation cables
• Replaceable inserts for
- 2 x Fast Ethernet connection
IE FC RJ45 modular outlet insert 2FE
- 1 x Gigabit Ethernet connection
IE FC RJ45 modular outlet insert 1GE
- 1 x Fast Ethernet connection, 1 x DC 24 V connection
IE FC RJ45 Modular Outlet Power Insert
■ Overview
• The managed Industrial Ethern et switches of the SCALANCE
X-200 product line are optimized for installing Industrial
Ethernet networks with 10/100 Mbit/s in a line, star and ring
topology
• Electrical or optical connection to stations or network in
accordance with the port type of the devices
• Rugged metal housing in S7-300 format for mounting on stan-
dard rail, S7 rail or for direct wall mounting in various positions
11
• Rugged, industry-standard station connections with
PROFINET-compatible plug-in connectors that offer additional
strain relief and bending strain relief thanks to latching on the
housing
• Redundant power supply
• Diagnostics on the device by means of LEDs
(power, link status, data communication)
• Error signaling contact with easy adjustment using the SET
button
• The devices feature PROFINET diagnostics, SNMP access,
integral Web server and automatic e-mail sending function for
remote diagnosis and signaling over the network.
■ Overview
• Specially designed for config uring isochrone real-time Indus-
trial Ethernet networks in line, star and ring topologies for
10/100 Mbit/s
• Combination of the switching mechanisms “Cut Through”; and
“Store and Forward”; for optimized performance
• Electrical or optical connection to stations or network in
accordance with the port type of the devices
• Rugged metal housing for space-saving cabinet mounting on
standard rails, S7-300 DIN rail or for wall mounting
• Industry-standard compatible station connections with
PROFINET-compatible plug-in connectors that offer additional
strain relief and bending strain relief thanks to latching on the
housing
• Redundant power supply
• Can be used for fault-tolera nt applications and can be
replaced during normal operation thanks to redundant
transmission characteristics
• Diagnostics on the device by means of LEDs
(power, link status, data communication)
• Error signaling contact with easy adjustment using the SET
button
• The devices feature PROFINET diagnostics, SNMP access,
integral Web server and automatic e-mail sending function for
remote diagnosis and signaling over the network
■ Overview
• The CPU with a large program memory and quantity framework
for demanding requirements
• Distributed intelligence in Component based Automation
(CBA) on PROFINET
• PROFINET proxy for intelligent devices on PROFIBUS DP in
Component based Automation (CBA)
11 • PROFINET I/O controller for op erating distributed I/O on
PROFINET
• For multisector automation tasks in the construction of series
machines, special machines and plants
• Used as a central controller on production lines with central
and distributed I/O
• For extensive I/O configurations
• For setting up distributed I/O structures
• High processing performance in binary and floating-point
arithmetic
• Combined MPI/PROFIBUS DP-master/slave interface
• Supports as an option the us e of SIMATIC Engineering Tools
Micro memory card required for operation of CPU.
■ Overview
• Optimized for applications that demand high flexibility and
integration capability.
• SIMATIC WinAC software PLCs comprise the following
products
- WinAC Basis
- WinAC RTX
• WinAC Basis:
- The low-cost solution for PC-based control tasks
- For data-intensive processes in connection with extensive
PC tasks
• WinAC RTX:
- The software solution for tasks which demand hard determin-
istics
- With real-time extension to provide deterministic behavior for
the control unit
CP 343-1
■ Overview
• Connection of SIMATIC S7-300 to Industrial Ethernet
- 10/100 Mbit/s full/half duplex connection with Autosensing for
automatic switchover
- Connection for RJ45
- Multi-protocol operation with TCP and UDP transport protocol
- Adjustable Keep Alive function
• Communication services:
- TCP/IP und UDP transport protocol 11
- PG/OP communication
- S7 communication (client, server, multiplexing)
- S5-compatible communication
• Multicast for UPD
• Remote programming and initial startup via the network
• SNMP-supported diagnostics
• Configuration of CP 343-1 wi th the NCM S7 options package
for Industrial Ethernet (integrated into STEP 7)
• Cross-network programming device/operator panel
communication through S7 routing
■ Overview
• Connection of SIMATIC S7-300 to Industrial Ethernet
- 10/100 Mbit/s full/half duplex connection with autosensing
- Connection via RJ45
- Multi-protocol operation for TCP/IP and UDP
- Adjustable Keep Alive function
• Communication services:
- TCP/IP und UDP transport protocol:
Multicast for UDP
- Programming device/operator panel communication:
Network-wide PG/OP communication through S7 Routing
- S7 communication
- S5-compatible communication
- IT communication:
HTTP communication supports access to process data
through Web browsers;
FTP communication supports program-controlled FTP client
communication,
Access to data blocks through FTP server,
Data handling for own file system through FTP,
E-mail
• IP address assignment via DHCP, simple PC tool or via
program block per HMI (in exclusive server mode)
• IP address-based access protection
• Remote programming and initial startup via the network
• Clock synchronization of the CPU via NTP or SIMATIC
procedure
• Integration into network management systems through the
support of SNMP V1 MIB-II
CP 443-1 Advanced
■ Overview
• Communication services:
- PROFINET IO Controller
- PROFINET CBA
- ISO, TCP/IP and UDP transport protocols:
Multicast for UDP
- Programming device/operator panel communication:
11 Cross-network by means of S7 routing
- S7 communication
- S5-compatible communication
- IT communication:
HTTP communication supports access to process data
through Web browsers;
FTP communication supports program-controlled FTP client
communication,
Access to data blocks through FTP server,
Data handling for own file system through FTP, E-mail
• IP address assignment via DHCP, si mple PC tool or via the user
program (e.g. HMI)
• Access protection by means of configurable access list
• Single-width module wi th integrated 4-port switch saves space
in the rack and control cabinet. Thanks to the integrated au-
tocrossing function, the CP 443-1 Advanced is very well suited
for establishing small local networks.
• Module replacement without programming device; all informa-
tion is stored on the C-PLUG (also file system for IT functions).
• Connection of SIMATIC S7-400 to Industrial Ethernet • Extensive diagnostic function s for all modules in the rack
- 10/100 Mbit/s full/half duplex connection with autosensing
- Connection via RJ45
- Multi-protocol operation for ISO, TCP/IP and UDP
- Adjustable Keep Alive function
■ Overview
■ Overview
PC/PG
CP 1612 CP 1512
SOFTNET PN IO
Industrial Ethernet
IE/PB Link PN IO
G_IK10_XX_10073
S7-300
ET 200S
■ Overview
• Access to variables in PROFIN ET CBA components over the
OPC interface
ProTool/Pro Microsoft Office SIMATIC NET
OPC client OPC client OPC Scout • Use of the objects and symbols defined using the
PROFINET engineering tool SIMATIC iMap and STEP 7
• Adding PROFINET functionality to existing installations. This
enables it to be used in parallel with other communication pro-
PN CBA tocols such as S7 communication with SOFTNET-S7 for Indus-
S7-OPC server OPC server trial Ethernet.
• OPC Scout as an OPC client with browser functions for the
variables of the PROFINET CBA components
S7 PROFINET
Communication Communication
S7 Communication PROFINET
for process Communication
data Industrial Ethernet
PROFINET PROFINET
G_IK10_XX_10122
CBA CBA
Component Component
ET 200S ET 200S
SIMATIC iMap
■ Overview
• Component-based software tool for configuration of communi-
cation in distributed automation solutions 11
• Based on PROFINET standard
• For simple graphic configuring of communication between
system modules and machine-machine on the production line
• Open for PROFINET devices from different vendors on
Industrial Ethernet
• Runs on Windows 2000 and Windows XP
■ Overview
• Interface module for connect ing the ET 200S to PROFINET
• Performs all data communication with the PROFINET
I/O Controller
SIMATIC VS 130-2
■ Overview
• Recognizes codes on a wide variety of components and
surfaces, e.g. on
- Paper or plastic labels
- Plastic parts
- PCBs
- Metal objects
11 • Recognizes codes marked in a wide variety of ways, e.g.
- Printed
- Punched
- Laser-etched
- Drilled
• No parameter settings are requir ed to adjust the sensor to
different surfaces and marking types. The vision sensor is
"trained" automatically with a sample of the code to be read.
This eliminates the need for programming and parameter
definition.
• Can be used for the following applications:
- complete or partial reading of coded information
- complete or partial comparison of coded information with a
defined sequence of characters
• Web-based user interface can run on various platforms
(e.g. browser, WinCC, etc.) for visualization and input.
• Remote maintenance via we b-based user interface.
• Remote control via integral digital inputs, PROFIBUS or
• Vision sensor for decoding Data Matrix Code (DMC) as de- PROFINET (available soon).
fined in ECC200. Other codes (QR, PDF417) available soon • Supplied as a complete pack age in various versions for
(delivery stage 2). 2D code types, e.g. customer-specific different code sizes.
codes, can be added.
■ Overview
• Compact network transition be tween Industrial Ethernet and
PROFIBUS
• Connection to Industrial Ethernet
with 10/100 Mbit/s full/half duplex connection with autosensing
for automatic switchover
• Connection to PROFIBUS
with 9.6 kbit/s to 12 Mbit/s incl. 45.45 kbit/s for PROFIBUS PA
• PROFINET IO proxy;
connection of PROFIBUS DP slaves to PROFINET IO controller
via real-time communication (RT) according to PROFINET
standard:
- From the viewpoint of the IO-controller, all DP slaves are han-
dled like I/O devices of the Ethernet interface, such as IO de-
vices with an Ethernet interface, i.e. the IE/PB Link PN IO is its
proxy.
• Cross-network programming device/operator panel commu-
nication by S7 routing, i.e. all S7 stations can be remotely
programmed by the programming device on the Industrial
Ethernet or PROFIBUS.
• Cross-network access to data of S7 stations for visualization by
means of S7 OPC server and S7 routing;
- Via the IE/PB Link PN IO access can be made from the PC on
the Industrial Ethernet (e.g. for HMI applications with OPC
Client interface) by means of S7 OPC server, to all data of the
S7 stations on the PROFIBUS.
• Module replacement without the need for a PG, using the
C-PLUG swap media for backing up the configuration data
IWLAN/PB Link PN IO
■ Overview
• PROFIBUS master interface for flex ible integration of field level
systems into an IWLAN radio infrastructure according to
IEEE 802.11b/g and IEEE 802.11a with up to 54 Mbit/s at
2.4 GHz or 5 GHz, e.g. with SCALANCE W access points
• PROFINET IO proxy;
connection of PROFIBUS DP slaves to PROFINET IO controller
according to PROFINET standard:
11
- From the viewpoint of the IO-controller, all DP slaves are
handled like I/O devices of the Ethernet interface, such as IO
devices with an Ethernet interface, i.e. the IWLAN/PB Link PN
IO is its proxy.
• Connection of a WLAN antenna or alternatively an antenna for
operation with an RCoax cable (leakage)
• Communication with programmable controllers in mobile
applications such as automated guided vehicles, storage and
retrieval systems or monorail overhead conveyors
• Direct substitution of soluti ons with Power Rail Booster for
PROFIBUS using sliding contacts with non-contact data trans-
mission technology;
Advantages: No wear
• For installation in the casing of the Power Rail Booster (com-
mon with overhead conveyor and automated guided vehicles)
to IP20
• High reliability by reserving the data transmission rate and
• Compact router between Industrial Ethernet Wireless LAN and cyclic monitoring of the radio link
PROFIBUS • High degree of protection agai nst unauthorized access thanks
to WPA and 128-bit encoding (AES)
• Module replacement without the need for a PG, using the
C-PLUG swap media for backing up the configuration data
• Integration in STEP 7
■ Overview
■ Overview
PC Server
Switch Switch SCALANCE X414 3E
SCALANCE X-400
automation network
Industrial Ethernet
Security Module
SCALANCE S
Panel
PC
G_IK10_XX_30015
Robot cells Robot cell
Modern automation technology is based on communication and Advantages of the industrial security concept:
the trend toward increased networking of individual manufactur- • Protection from espionage and data manipulation
ing islands. It is becoming more and more important to integrate
all the manufacturing components into a uniform network that • Protection against overloading of the communication system
merges with the office network and the corporate Intranet. There • Protection against mutual interference
is also a requirement for remote access for servicing, the in- • Protection against addressing mistakes
creasing use of IT mechanisms such as Web servers and e-mail
with programmable controllers as well as the use of wireless • Easy, user friendly configuratio n and administration without the
LANs. In this manner, industrial communication interacts more need for specialist knowledge using IT security techniques.
and more with the IT environment and is now subjected to the Changes or modifications to the existing network structure are
same dangers that are well-known from the office and IT not necessary
environment, such as hackers, viruses, worms and Trojans. • No changes or modification of the existing applications or
network stations are necessary
The current security concepts are tailored to the office world and • Rugged, industry-compatible design
require constant administration and specialist knowledge. They
are not usually conversant with the special protocol landscape SCALANCE S security modules offer a scaleable security
of industrial communication and are not designed to withstand functionality:
the harsh environmental conditions. • Firewall for protecting the programmable controllers from un-
authorized access regardless of the size of the network to be
With its security concept, Siemens offers a safety solution spe- protected.
cially designed for industrial automation engineering that satis- • Supplementary or alternative VPN (Virtual Private Network) for
fies the specific requirements of this application environment. reliable authentication of the communication partners and
encryption of the transmitted data
• SOFTNET security client for secure access from PCs and
notebooks to programmable controllers protected by
SCALANCE S.
■ Overview
■ Overview
• SOFTNET Security Client is a co mponent part of the industrial • Data transmission is protecte d against incorrect user opera-
security concept for protecting automation devices and for tion, listening in, espionage and malignant intervention;
security during data exchange between automation systems. communication can only take place between authenticated
• VPN client for programming devices, PCs and notebook and authorized devices
computers in the industrial environment; • Uses the IPSec mechanisms alre ady tried and tested in the
secure VPN client access is supported through SCALANCE S office sector for setting up and operating VPNs.
protected automation systems
PC/PG/notebook
with CP 1612 and
SOFTNET Security Client
software PC/PG/notebook
with CP 7515 and
SOFTNET Security Client
software
Access Point
SCALANCE W788-1PRO
Industrial Ethernet
G_IK10_XX_10083
Automation cell 1 Automation cell 2 Automation cell 3
secure access
Secure access to automation cells secured by SCALANCE S612/S613 with SOFTNET Security Client 11
■ Overview
RCoax leaky wave cables operated as antennae from
SCALANCE W access points provide reliable radio links in areas
in which conventional antenna technology can only be installed
at considerable expense.
• Rugged coaxial cable that can be easily installed;
this allows the radio field to be planned by personnel without
special training even in areas that are problematic for radio
techniques.
• A controlled radio field is provided around the leaky wave
cable making it ideally suited to tunnels, channels and any type
of rail vehicles.
• Broadband cable to complement IWLAN products from
SIMATIC NET according to IEEE 802.11b/g and IEEE 802.11a
especially in the range of the popular Industrial Wireless LAN
frequency bands at 2.4 GHz and 5 GHz
• Infeed stations based on the SCALANCE W788-1PRO access
point
• Mobile stations (e.g. Ethernet client module SCALANCE W744-
1PRO, IWLAN/PSDFDFB Link PN IO) with an antenna opti-
mized for the particular application
■ Overview
• Not only devices with increased reliability requirements
(IWLAN), but also standard wireless LAN products
(IEEE 802.11) can be operated on the same radio network.
• Operation at 2.4 GHz or 5 GHz with data rates of up to
54 Mbit/s in one device
• Industrial application thanks to rugged metal housing with
11 protection against the ingress of water and dust to the IP65
degree of protection;
also for outdoor use at -20°C to +60°C
(resistant to condensation)
• SCALANCE W788-1PRO and W788-2PRO offer several
operating modes in one device:
- Set up of wide area wireless networks (infrastructure) with
ranges of up to 30 m indoors (about 100 m outdoors)
- Point-to-point connection of Industrial Ethernet segments
over large distances (several 100 m)
• SCALANCE W744-1PRO is used for connecting mobile
devices with Industrial Ethernet access to an IWLAN wireless
network
• High reliability due to reservatio n of the data rate for critical
nodes
• High degree of protection agai nst unauthorized access thanks
to WPA and 128-bit encoding (AES)
• Support of the configuration with security wizard and online
• The Access Points SCALANCE W788-1PRO, W788-2PRO and help
the Industrial Ethernet Client Module SCALANCE W744-1PRO • Simple management with Web-Server and SNMP
are ideally suited to the task of setting up industrial wireless
local area networks (IWLAN) with reliable communication. • Fast replacement of devices in event of failure, by means of
optional C-PLUG (configuration plug) switching medium
■ Overview
The Industrial Ethernet ASIC ERTEC 400 (Enhanced Realtime
Ethernet Controller) is a high-performance Ethernet Controller
with an integral 4-port real-time switch and integral 32-bit micro-
processor developed for industrial use. It impresses customers
with its rugged construction, specific automation functions and
openness to the IT world.
• Easy space-saving connection of devices to switched
10/100 Mbit Ethernet
• No need for external network components since the switches
are integrated into the device
• Integrated high-performance ARM 946 RISC for optimized
communications integration and application tasks
• PCI interface for optimal inte gration into PC-based environ-
ments
• Specific communication function s for automation technology
secure the position of the technology as front runner for time-
critical applications through real-time characteristics
• Fault-tolerant applications can be replaced during normal
operation thanks to redundant transmission characteristics
• The user is aided by the ERTEC 400 development kit and
worldwide technical support.
■ Overview
• Development kit for the development of PROFINET and Indus-
trial Ethernet devices with integral real-time switch
• Possible applications:
- Development of IO field devices with a PROFINET interface
- Development of drives with a PROFINET interface
- Development of any other device with an Industrial Ethernet 11
interface
■ Overview
With its forward-looking design, modular and open architecture 7 Extensive fieldbus integration
based on the latest SIMATIC technology, consistent use of indu- 7 Flexible solutions for batch processes
stry standards and I&C functionality combined with high perfor- 7 Direct interface with the IT world
mance, the SIMATIC PCS 7 process control system supports the
cost-effective implementation and economic operation of I&C Flexibility and scalability
systems in all lifecycle phases and takes all relevant issues into
The modular architecture based on selected hardware and soft-
account: from planning, engineering, commissioning and trai-
ware components from the SIMATIC standard range allows
ning through operation, maintenance, and service and beyond
SIMATIC PCS 7 to be adapted to meet all kinds of customer
to expansion and retrofitting. SIMATIC PCS 7 combines high
requirements during system configuration and makes expansion
performance and reliability with simple and secure operation
or reconfiguration easy in the event of subsequent capacity
and high levels of user-friendliness.
expansion or technological changes. SIMATIC PCS 7 can be
The primary benefits of Totally Integrated Automation with the scaled from a small individual system with some 160 measuring
SIMATIC PCS 7 process control system are as follows: points (common synonyms: PCE stations, I&C stations), e.g., for
• Development, implementation and lifecycle costs can be cal- lab automation or use in pilot plant stations to a distributed multi-
culated. user system based on a client/server architecture with some
60,000 measuring points for automating a very large production
• The time and money spent on engineering is minimized. facility or a system network at a production site.
• It offers options for process optimization.
SIMATIC PCS 7 is therefore able to cater for systems of all sizes
• It can be adapted to meet changing requirements. and if the system grows, SIMATIC PCS 7 simply grows with it!
• Advantages resulting from th e use of SIMATIC standard com-
Open for the future
ponents, such as:
- Low hardware and engineering costs SIMATIC PCS 7 is based on the modular hardware and software
- Proven quality and stability components in the Totally Integrated Automation system spec-
- System components can be defined and selected quickly trum, which complement one another perfectly. These compon-
and easily ents can be expanded and innovated seamlessly and with little
- Low replacement part costs effort and are open for the future via long-term stable interfaces.
- Short delivery times for replacement parts and expansion This makes long-term protection of customer investments possi-
components ble, despite the fast pace of innovation and short product cy-
- Worldwide availability
- Reduced logistics, maintenance and training costs
cles.
SIMATIC PCS 7 makes consistent use of new, powerful techno-
11
logies and international standards such as IEC, XML, PROFI-
■ Function BUS, Ethernet, TCP/IP, OPC, @aGlance, ISA S88 or S95, to
name but a few.
An integrated and homogeneous overall system solution
With SIMATIC PCS 7, openness extends across all levels and
As a modern process control system, SIMATIC PCS 7 can pro- applies to automation systems and process I/O just as it does to
vide an integrated and homogeneous overall system solution operator and engineering systems, industrial communicaiton
both on its own and in conjunction with Motion Control and networks or the SIMATIC IT framework as the link to information,
SIMATIC. Its popularity is increasing along with the demand for coordination and planning tools for company management.
seamlessly integrated universal automation engineering
solutions, which is determined by sustained competition and However, it is not just the system architecture, horizontal and ver-
price pressure, the demand for increasingly flexible production tical integration and communication that are characterized by
systems and the need for increased productivity. openness. It is a feature that is also evident in the programming
and data transfer interfaces for user programs as well as in the
Against the background of ever-increasing complexity, in parti- import and export functions for graphics, text and data, e.g.,
cular due to the merging of automation engineering with informa- from the CAD/CAE world.
tion technology, horizontal and vertical integrated system plat-
forms are taking on more and more importance in comparison This means that SIMATIC PCS 7 can also be combined with
with automation solutions with so-called "best-in-class pro- components supplied by other manufacturers and integrated
ducts". As an integral component of Totally Integrated Automa- into existing infrastructures.
tion, SIMATIC PCS 7 is therefore ideally equipped to meet the
challenges of the future.
■ Overview
Push Button Panels Micro Panels Mobile Panels Panels Multi Panels Panel PCs HMI-Software
WinCC flexible
and monitoring at
ProTool
Operator control
machine level
Shaping and influencing progress SIMATIC HMI offers a complete range of products for the many
and varied tasks involved in operator control and monitoring,
Processes are becoming more complex and machine and from simple control units to process visualization systems.
system function requirements are on the increase. Customized solutions are also possible.
Making the increasingly complex increasingly simple is our
incentive whenever we develop new HMI products. Open, stan-
dardized hardware and software interfaces support application
options all over the world. Beyond the automated process,
SIMATIC HMI is an integral part of the company-wide IT lands-
cape.
■ Overview
The OP73micro and the TP 177micro can be connected to all
SIMATIC S7-200 CPUs using the standard MPI bus cable or
PROFIBUS DP cables (network integration possible).
Interface: 1xRS 485
OP 73micro1)
• Operator panel for controlling and monitoring machines and
systems.
• Graphics in a new dimension: compact and clever.
• Pixel-graphics 3" LC display, monochrom.
• Large keys for improved operational reliability.
• Easy to handle and configure.
• Same installation cutout as the OP 3 and TD 200.
TP 177micro1)
• Touch panel for controlling and monitoring small machines
and systems.
• Pixel-graphics 5.7" STN touch sc reen (analog/resistive), blue
The panels can be used wherever machines and systems are mode (4 levels).
controlled and monitored locally - in production, process and
• Can also be used where space is at a premium thanks to ver-
building automation alike. They are used in all types of sectors
tical installation.
and applications.
• On-screen alphanumerical keyboard.
Micro Panels have been designed specifically for use with
SIMATIC S7-200. They are configured using the SIMATIC WinCC • Same installation cutout as the TP 070/TP 170micro.
flexible Micro engineering software. Further information
• Catalog ST 80
• Internet: http://www.siemens.com/panels
■ Overview
The SIMATIC OP 73/OP 77A and OP 77B are part of a complete
and integrated SIMATIC HMI panel family, which supports flexi-
ble configuration with the SIMATIC WinCC flexible engineering
software. WinCC supports the flexible migration of existing
OP 3/OP 7 projects to OP 73/OP 77 projects. The previous engi-
neering work is thus retained. 11
• Graphics in a new dimension: compact and clever.
• All interfaces (e.g., MPI, PROFIBUS DP) are onboard inter-
faces.
• Can be connected to:
- SIMATIC S7-200/-300/-400.
- SIMATIC WinAC Software/Slot PLC.
• Full-contrast display for good legibility.
• Large keys for improved operational reliability.
• Easy to handle and configure.
• Can be used all over the world:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets).
The panels can be used wherever machines and systems are
- Up to 5 languages can be switched online.
controlled and monitored locally - in production, process and
- Language-dependent texts and graphics.
building automation alike. They are used in all types of sectors
and applications. OP 731)
• Pixel-graphics 3" LC display, monochrom.
• Successor to the OP 3 operator panel.
• 8 system keys, 4 user-def inable function keys.
■ Overview (continued)
OP 77A1) • It can also be connected to:
• Pixel-graphics 4.5" LC display, monochrom. - SIMATIC S5.
- SIMATIC 505.
• Successor to the OP 7 operator panel. - Non-Siemens controls.
• 23 system keys, 8 user-definable function keys.
Further information
OP 77B • Catalog ST 80
• Pixel-graphics 4.5" LC display, monochrom. • Internet: http://www.siemens.com/panels
• The OP 77B is the successor to the OP 7 operator panel.
• 23 system keys, 8 user-definable function keys.
SIMATIC TP 177A
■ Overview
The TP 177A1) is the innovative successor to the TP 170A touch
panel:
• Low-cost first-time user soluti on for the range of graphics-
compatible touch panels with all necessary basic functions for
simple tasks.
• Pixel-graphics 5.7" STN touch sc reen (analog/resistive), blue
mode (4 levels).
• All interfaces (e.g., MPI, PROFIBUS DP) are onboard inter-
faces.
• Can also be used where space is at a premium thanks to ver-
tical installation.
• With fast response times, the TP 177A is also ideal for jog
mode.
• The TP 177A can be connected to:
- SIMATIC S7-200/-300/-400
- SIMATIC WinAC Software/Slot PLC
• Can be used all over the world:
- 32 languages can be configured (incl. Asian and Cyrillic
The panels can be used wherever machines and systems are character sets).
controlled and monitored locally - in production, process and - Up to 5 languages can be switched online.
building automation alike. They are used in all types of sectors - Language-dependent texts and graphics.
11 and applications.
SIMATIC TP 177A1) touch panels are part of a complete and in-
Further information
tegrated SIMATIC HMI panel family, which supports flexible con- • Catalog ST 80
figuration with the SIMATIC WinCC flexible engineering software. • Internet: http://www.siemens.com/panels
Projects created with ProTool can be transferred to WinCC flexi-
ble.
■ Overview
• 5.7" TFT Liquid Crystal Display (LCD).
• All interfaces (e.g., MPI, PROFIB US DP, USB, Ethernet, serial)
are onboard interfaces.
• The MP 270 6" is configured exclusively with WinCC flexible.
• The MP 270 6" can be connected to:
- SIMATIC S7-200/-300/-400
- SIMATIC WinAC
- SIMATIC S5
- SIMATIC 505
- Non-Siemens controls
• Can be used all over the world:
- 32 languages can be configured (incl. Asian and Cyrillic
character sets).
- Up to 5 languages can be switched online.
- Language-dependent texts and graphics.
Further information
• Catalog ST 80
Like operator panels, Multi Panels are used for controlling and • Internet: http://www.siemens.com/panels
monitoring machines locally.
Multi panels (MPs) also support the installation of additional
applications.
11
■ Overview
PROFIBUS
0 1
00 00
00 7
00 00
s PROFIBUS
Addr.
6GK1415-0AA00
instabus EIB
Power DP/EIB-Link
DP/BF
EIB/BF
24V EIB
Phys. Adr.
SIMATC NET stands for industrial communication. SIMATIC NET SCALANCE is the name for the new generation of components
products can be used to set up solutions for integrated data and for setting up integrated networks:
information flow from the field level right up to the corporate ma- • Conducted or IWLAN (Industrial Wireless LAN).
nagement level.
• In industrial environments and similar.
The increasing use of Industrial Ethernet in automation is making
two subjects within Totally Integrated Automation ever more im- Three versions:
11 portant: PROFINET and SCALANCE.
PROFINET, the open and cross-vendor Industrial Ethernet stan-
• SCALANCE S security modules are at the heart of Siemens'
ground-breaking security concept for protecting networks and
data.
dard, supports integrated, company-wide communication.
PROFINET also supports the direct connection of distributed • Based on Industrial Wireless LAN, SCALANCE W supports in-
field devices to Industrial Ethernet and the solution of Motion tegrated communication as far as areas that until now have
Control applications in isochrone mode. PROFINET also been difficult or even impossible to access.
supports distributed automation with the assistance of compo- • SCALANCE X modular switches (active network components)
nent engineering. make networks fit for the future.
SIMATIC NET supports the Industrial Ethernet, PROFINET,
PROFIBUS, AS-Interface and Konnex bus systems.
Further information
• Catalog IK PI
• Catalog CA 01
■ Overview
• Protection against maloperation, prevention of unauthorized
access, avoidance of malfunctions and communication over-
load, data transmission encryption, protection against espio-
nage and manipulation.
• Easy to use thanks to minimu m configuration and no special
knowledge of IT security is required.
• No changes or modifications need to be made to the existing
network structure/applications or network nodes.
• Communication security is protocol-independent
(PROFINET, Ethernet/IP, MODBUS TCP, etc.).
SOFTNET Security Client software
• Secure access to automation devices/complete automation
cells from programming devices or notebook computers.
• Easy to use on portable PCs in conjunction with the SOFTNET
Security Client, since an external device is not required for
communication security.
• Integrated security concept fo r automation engineering with
SCALANCE S612/S613 security modules SCALANCE S and SOFTNET Security Client.
• Security modules for the protec tion of automation networks • Protecting data transmission against espionage and manipu-
and security during data exchange between automation sy- lation by means of certified standards.
stems. Communication can only take place between authenti- • Easy to use, no specialist knowledge required.
cated and authorized devices.
■ Overview
SCALANCE W network components • Not only devices with increased reliability requirements
(IWLAN), but also standard wireless LAN products
(IEEE 802.11) can be operated on the same radio network.
• Operation at 2.4 GHz or 5 GHz with data rates up to 54 Mbps
in a single device.
• Suitable for industrial use th anks to rugged metal housing pro-
tected against water and dust with IP65 degree of protection;
can also be operated outdoors at temperatures between -
20°C and +60°C (resistant to condensation). 11
• SCALANCE W788-1PRO and W788-2PRO offer several ope-
rating modes in one device:
- Setting up of two-dimensional radio networks (infrastructure)
with ranges up to 30 m indoors (approx. 100 m outdoors).
- Point-to-point connection of Industrial Ethernet segments
across long distances (several 100 m).
• SCALANCE W744-1PRO can be used to interface portable
devices with Industrial Ethernet connections to an IWLAN
radio network.
• High reliability thanks to reservat ion of data rate for critical
nodes.
• SCALANCE W788-1PRO and W788-2PRO access points and
SCALANCE W744-1PRO Industrial Ethernet client modules • High security against unauthorized access thanks to WPA and
are ideal for setting up IWLAN (Industrial Wireless LAN) radio 128-bit encryption (AES).
networks with reliable communication. • Support during configuration wi th Security Wizard and Online
Help.
• Easy to manage with Web Server and SNMP.
• Devices can be replaced quickly in the event of an error using
the optional C-PLUG (configuration plug) replacement me-
dium.
■ Overview (continued)
Clients for SCALANCE W: • Integration into STEP 7/NCM PC.
PC card CP 7515 and SCALANCE W744-1PRO • Communication services using ISO or TCP/IP transport proto-
cols: PG communication, S7 communication, S5-compatible
communication (SEND/RECEIVE).
• Used in both industrial applic ations and in the office/enter-
prise sector.
• The appropriate OPC server and configuration tools are inclu-
ded in the scope of supply of the respective communication
software.
Accessories for SCALANCE W: Antennas and power supply
unit
Antennas
• The use of separate antennas increases the reliability of radio
links by optimizing signal reception and distribution.
• Can be used on both IWLAN (Industrial Wireless LAN) radio
networks and standard wireless LAN (IEEE 802.11) at 2.4 GHz
and 5 GHz with data rates of up to 54 Mbps.
• Easy to assemble, as the ante nnas are supplied preassem-
bled with antenna cable and RSMA connector; an extension
• The CP 7515 communications pr ocessor is a PC card (32-bit cable can be purchases as an option.
CardBus) for operation on an IWLAN (Industrial Wireless LAN) • All antenna cables are flamepro of, resistant to chemicals and
radio network with reliable communication. The CP 7515 can free from silicone/halogen.
be used in a standard WLAN to IEEE 802.11b/g and
IEEE 802.11a at 2.4 GHz or 5 GHz. Power supply
Transmission rates up to 54 Mbps (108 Mbps in turbo mode) • The PS791-1PRO power supply is an AC/DC power supply
with IEEE 802.11g and IEEE 802.11a. module (10 W primary switched-mode regulator) for
• Two integrated antennas (anten na diversity) for reliable recep- SCALANCE W-700 and SCALANCE X-200 products.
tion in areas subject to high levels of interference. • Suitable for assembly directly on SCALANCE W-700 and
• High reliability thanks to reservat ion of data rate (only in con- SCALANCE X-200 devices, but also for wall or rail mounting
junction with SCALANCE W-700 access points). (DIN or S7-300).
• High security against unauthor ized access thanks to WPA and • Rugged metal housing protected against water and dust with
128-bit encryption (AES). IP65 degree of protection.
• Operating temperature -20 °C to +60 °C.
■ Overview (continued)
Unmanaged Industrial Ethernet Switches SCALANCE X-100 • PROFINET-enabled.
• Standard remote diagnostics functions (SNMP, Web Server).
• IRT devices support applications with strict real-time require-
ments and maximum availability.
• Devices with high degrees of protection support configurati-
ons without control cabinets.
Modular Industrial Ethernet Switches SCALANCE X-400
■ Overview
Routers • Compact routers suitable for industrial use.
• Support of the PROFINET stan dard (routers for Industrial
Ethernet).
• Consistent modularization of systems/machines thanks to the
ease with which distributed intelligence can be handled.
• Access to process data from all company levels.
• Worldwide access to PROFIBUS node data via Industrial
Ethernet and Internet for vertical integration.
• Optimization of a system from a central point.
• Loading of STEP 7 programs from a central point.
SINAUT ST7
■ Overview
TIM transmission modules for telecontrol systems SINAUT MD modems
with SIMATIC S7
• S7-300 modems
• 24 V DC
• RS 232 and RS 485 interfaces
• MD2 leased-line modem
• MD3 for the analog telephone network
• MD4 for the digital ISDN network
LTOP
overvoltage protection modules
11
■ Overview ■ Benefits
SIMATIC Microbox PC 420 and Box PC 620 and 840
Compact dimensions
With a maximum mounting depth of 100 mm (80 mm without CD-
ROM), the SIMATIC Box PC 620 can be used even in the smal-
lest of spaces.
Rugged design
The overall design aims to achieve maximum safety for vibration
and shock loads. For example, a special vibration-absorbing
suspension of the hard disk ensures absolute operational relia-
bility, even at high mechanical loads.
Service-friendly device design
The PC box can simply be folded out for speedy component
replacement. The inside of the device, where the processor and
slots are located, can be accessed easily for subsequent expan-
sions.
Integrated interfaces
SIMATIC Box PC provides particularly rugged industrial PC sy-
stems for powerful yet compact applications for builders of ma- On SIMATIC Box PCs, all interfaces are located on one side. Box
chines, systems and control cabinets. Three device classes are PCs can be interfaced with the control/cell level via onboard
available for various requirements: Ethernet interfaces and communicate in the field via an integra-
ted PROFIBUS interface, which is available as an option. Exter-
• SIMATIC Microbox PC 420 - ultra-compact, rugged and nal monitors or displays can be connected via a VGA and LVDS
maintenance-free. interface.
• SIMATIC Box PC 620 - high pe rformance where space is at a
Flexibility
premium.
• SIMATIC Box PC 840 - maxi mum performance with high With its 5 free PC slots, the SIMATIC Box PC 840 in particular of-
extendibility. fers considerable leeway for expansions. All Box PCs have CE
certification for use in industrial applications and domestic/com-
Highly suited for industrial environments mercial applications and can therefore be used in building auto-
• High vibration/shock load during operation. mation or public installations in addition to industrial applicati-
ons.
• Wide operating temperature range.
• Extremely service-friendly. Continuity
• Outstanding diagnostics. Through continuity in the availability of identical components,
such as motherboards designed and produced by Siemens,
Ideal for industrial applications SIMATIC Box PCs offer high investment security. Long-term
• Integrated PROFIBUS/MPI interface (optional). functionality is also assured for the hardware (e.g., ISA) and soft-
• ISA and PCI slots or PC/104-Plus slots. ware (Windows NT).
• Components are highly flexible and support expansion.
• Minimum dimensions.
Options
SIMATIC Box PCs can be ordered in custom configurations and
11
• Maximum performance. are supplied ready for use. The high system availability by de-
sign can be further extended by means of additional data bak-
High investment security kup options (e.g., RAID system, SIMATIC PC/PG ImageCreator)
• Guaranteed availability of repl acement parts for at least 5 and a highly-efficient SW program for self-diagnosis (SIMATIC
years. PC DiagMonitor).
• High component/design continuity.
■ Benefits
SIMATIC Rack PCs provide flexible high-availability industrial PC
systems for powerful yet compact applications in 19" techno- SIMATIC Rack PC IL 40 S
logy. Maximum performance at an affordable price
Two device classes are available for various requirements: A SIMATIC Rack PC Industrial Lite 40 S should be your first
• SIMATIC Rack PC IL 40 S - maximum performance at an affor- choice for applications requiring a very powerful industrial PC
dable price. platform.
• SIMATIC Rack PC 840 - maximum extendibility combined with Performance
maximum suitability for industrial applications
The Rack PC IL 40 S is particularly geared to the standard PC
Shared industrial functionality world. Combined with high levels of innovation, this device offers
• High EMC: CE mark for industrial applications. a range of outstanding high-performance processors with hy-
per-threading (HT) technology in the field of industrial PCs.
• Overpressure ventilation concep t with fan on the front and
dust filter. Integrated interfaces
• Designed for 24-hour continuous operation. An onboard Ethernet interface is available for communication in
• Integrated parameterizable monitoring functions (tempera- the office world or at management level. Integrated USB inter-
ture, fan, watchdog). faces on the rear and front panels make connecting I/O devices
from the PC world (e.g., external hard disks for mobile data bak-
• Service-friendly device design. kup, barcode readers, external mouse for operation) child's play.
• Lockable front cover. For advanced graphics applications, a free AGP slot or a high-
• Prepared for mounting on a telescopic rail. performance graphics card for the connection of two monitors
are available.
11 SIMATIC Rack PC Industrial IL 40 S
The price
State-of-the-art technology
The Rack PC IL 40 S is a high-availability industrial PC at an
• State-of-the-art Intel technology affordable price.
• High performance and scalability
Options
• PCI and AGP slots
The SIMATIC Rack PC IL 40 S can be ordered in custom confi-
Basic industrial capability gurations and is supplied ready for use. The high system availa-
• Dust protection bility by design can be further extended by means of additional
data backup options (e.g., RAID1 system, SIMATIC PC Image-
• Service friendliness
Creator).
• CE mark for industrial and office applications
• Transportation lock for expansion cards
• Monitoring functions
Basic investment security
• Guaranteed availability of repl acement parts for at least 3
years.
■ Benefits (continued)
SIMATIC Rack PC 840 Integrated interfaces
Maximum extendibility combined with maximum suitability for An onboard Ethernet interface is available for communication in
industrial applications the office world or at management level. The fieldbus interface is
provided by an integrated PROFIBUS/MPI interface, which is
Thanks to its outstanding ruggedness, the Rack PC 840 is a se- available as an option. Integrated USB interfaces on the rear and
cure PC platform for use on the machine level. front panels make connecting I/O devices from the PC world
Rugged design child's play.
The overall design aims to achieve maximum safety in case of Extendibility
vibration and shock loads. For example, a special vibration-ab- With 10 free PC slots, the SIMATIC Rack PC 840 offers maximum
sorbing suspension of the hard disk ensures absolute operatio- leeway for expansions at a minimum mounting depth of 19".
nal reliability, even at high mechanical loads. A well-designed
ventilation concept ensures that even the maximum configura- Continuity
tion can support high operating temperatures - and dust protec-
tion is included. Through continuity in the availability of identical components,
such as motherboards designed and produced by Siemens, the
Service-friendly device design SIMATIC Rack PC 840 offers high investment security. Long-
term functionality is also assured for the hardware (e.g., ISA) and
Particular attention was paid to outstanding service friendliness. software (Windows NT).
PC components (e.g., slots, memory modules) are accessible
by hand. Fan filters and fans can be replaced without tools even Options
if installed.
The SIMATIC Rack PC 840 can be ordered in custom configura-
tions and is supplied ready for use. The high system availability
by design can be further extended by means of additional data
backup options (e.g., RAID1 system, SIMATIC PC/PG Image-
Creator) and a highly-efficient SW program for self-diagnosis
(SIMATIC PC DiagMonitor).
SIMATIC Panel PC
■ Overview
Shared industrial functionality
• IP65 degree of protection
• High EMC: CE mark for industrial applications
• Designed for 24-hour continuous operation
• MTBF backlighting 50,000 or 60,000 hours
• Onboard Ethernet 11
• Ambient operating temperature up to 45°C (max. configura-
tion)
SIMATIC Panel PC Industrial Lite 70 and Industrial Lite 77
Basic industrial capability
• Vibration load during operation 0.25 g
• Shock (impact) load during operation 1.0 g
Basic investment security
• Guaranteed availability of replacement parts for at least
3 years.
SIMATIC Panel PCs are suitable for use in standard control cabi- • State-of-the-art PC technology.
nets, consoles and control panels.
High system availability
Typical areas of application can be found in both production and
• SIMATIC PC/PG Image&Partition Creator – software tool for
process automation.
backing up hard disk data (optional).
Two device classes are available for various requirements:
High levels of component innovation
• SIMATIC Panel PC 670 an d SIMATIC Panel PC 870.
• Maximum processor performance
• SIMATIC Panel PC Industrial Lite 70 (IL 70) and SIMATIC Panel
• PCI slots
PC Industrial Lite 77 (IL 77).
Low-budget
• Low-cost first-time user solution
■ Overview
Sensors are the sense organs of machines and systems on Optical safety sensors
which automated production processes are executed. Siemens
offers a complete range of sensors for all types of requirements
in the production industry:
From simple object detection with contactless proximity swit-
ches, product tracking with electronic ID systems and quality
control with image processing systems, right up to safety sen-
sors for protecting persons in dangerous areas.
BERO proximity switches
11
■ Overview (continued)
SIMATIC Machine Vision
11
Siemens ST 70 · 2005
Supplementary components
Drive systems
SINAMICS
■ Overview
• An ideal and cost-effective so lution for pumps, fans, extru-
ders, mixers, etc.
Further information
• Catalog D11
• Internet:
www.siemens.com/sinamics-g150
SINAMICS S120 –
The flexible, modular drive system for complex single-axis
and multiple-axis applications from the lower to the upper
performance range
• Specifically for Motion Control and vector-controlled applicati-
ons in single-axis and multiple-axis applications in all areas of
mechanical and system engineering.
• Servo/vector control, V/f.
• Power range from 0.5 - 1200 kW.
• Various designs for different target applications.
The SINAMICS family • Highly flexible, e.g., thanks to modular system architecture,
various cooling methods, support of a wide range of mo-
• An integrated drive family for every application and every indus- tors/encoders, easy expandability.
try sector.
• Highly degree of scalability in terms of performance, number
• Broad power spectrum from 0. 12 kW to more than 1 MW. of axes, functionality.
• Wide scope of available function s, from simply V/f control to • Integrated safety functions.
servo control with high dynamic response.
• Extensive Motion Control functionality.
• Designed for total compatibilit y with other Siemens automa-
tion components. • Fault-tolerant and highly effici ent even in unstable systems.
• Common platform concept with uniform functionality, configu- • Automatic parameter assignment and simple drive installa-
ration, installation and operation as well as a standard diag- tion/optimization.
nostics concept and standard communication mechanisms. Further information
SINAMICS G110 – • SINAMICS S120 C Vector Control drive system
The versatile drive for the lower power range 5 kW-1200 kW: Catalog D21.1
• For speed-controlled applicatio ns (V/f) in 200 - 240 V systems. • SINAMICS S120 Servo Control drive system
• Power range from 0.12 - 3 kW. 0.5 kW - 107 kW: Catalog D21.2
• Supplied ready for connection to speed up the installation pro- • Internet:
cess. www.siemens.com/sinamics-s120
• Easy to install as supplied ready for connection. SINAMICS S150 –
• Available with integrated filter. The ready-to-use drive solution for complex single drives in
the medium to upper performance range
• Variants for increased flexibility and various communication
modes. • For applications with maximum requirements in terms of pre-
cision and dynamics in the medium to upper performance
• Can be used in a wide range of applications in industry and range, such as test bed drives, elevator and crane systems,
business. cross cutters and shears, conveyor belts, presses, cable win-
12 Further information ches, centrifuges.
• Catalog D11.1 • Ready-to-use control cabinet.
• Internet: • Power range from 75 - 1200 kW.
www.siemens.com/sinamics-s110 • Fault-tolerant and highly effici ent even in unstable systems.
SINAMICS G130/G150 – • Cost-effective operation thanks to energy recovery as stan-
The universal drive for single drives in speed-controlled dard.
applications in the medium and upper performance range • Reactive-power compensation possible.
• For speed-controlled standard applications in the medium • PROFIBUS interface supplied as standard for connection to
and upper performance range. higher-level controls.
• Standard cabinet ready for connection, can be supplied as a Further information
rack-mounting unit for system-specific installation.
• Catalog D21.3
• Power range from 75 - 800 kW.
• Internet:
• SINAMICS G150 cabinet unit s and SINAMICS G130 rack- www.siemens.com/sinamics-s150
mounting units 315 - 800 kW are supplied as standard with a
PROFIBUS interface for connection to higher-level controls.
■ Overview
• SIMODRIVE 611 universal, SIMODRIVE POSMO A,
POSMO CD/CA, POSMO SI with PROFIBUS DP connection
can easily be integrated into SIMATIC using the STEP 7 pro-
gramming software.
- SIMODRIVE POSMO A is an intelligent positioning motor with
integrated converter power section, motor control, posi-
tioning control and program memory.
- SIMODRIVE POSMO CD/CA are complete converter and
control units for a distributed drive system. Flexibility thanks
to the ability to install close to the motor, for various types of
motors.
- SIMODRIVE POSMO SI is a single-axis servo drive for distri-
buted servo drive systems, comprising a fully functional me-
chatronics unit
Drive ES engineering system: See Catalog Section 7,
Engineering Tools.
Further information:
• Drive system for connection to machine tools, robots, special • Catalog NC 60/DA 65.4
machines, manipulators, and production machines. • Internet:
• Comprising a SIMODRIVE 611 co nverter system with analog http://www.siemens.com/drivesolutions
and digital control modules and the SIMODRIVE 611 universal
control module for the operation of three-phase servo motors,
linear motors, three-phase main spindle motors, and standard
asynchronous motors.
12
Further information:
• Catalog DA 21.1
Internet:
http://www.siemens.com/automation
Further information:
• Catalogs DA 65.10/DA 65.11
• Internet:
http://www.siemens.com/drivesolutions
■ Overview
• Device versions:
- Vector Control for demanding continuous processes in all
sectors of industry and for all applications.
Supply voltages from 380 V to 690 V, 50/60 Hz;
power ratings from 0.55 kW to 2300 kW; higher power ratings
available as application.
- Motion Control for all servo applications, even those with the
most demanding technological requirements. Voltages from
380 V to 480 V; 50/60 Hz;
power ratings from 0.55 kW to 250 kW.
• Version with Active Front End for jerk-free and stable drive
technology possible.
• Connection to PROFIBUS DP via communication modules
possible.
• Extensive range of accessories and system components.
Drive ES engineering system: See Catalog Section 7,
Engineering Tools.
Further information:
• Fully digital frequency conver ters with IGBT power modules.
• Catalogs DA 65.10/DA 65.11
• Can be used for single-motor and sectional drives.
• Internet:
• Types of construction: http://www.siemens.com/drivesolutions
Compact PLUS, compact, rack-mounting, and cabinet units.
SIRIUS time-delay,
monitoring and all-or-nothing relays
■ Overview
Interface relays 3TX70 and LZX
Plug-in relay connector 3TX701, overall width 6.2 mm:
• Plug-in relays: At the end of its service life, the relay can be re-
placed without having to disconnect the wiring.
• Wire entry and terminal screw can be accessed easily from
the front.
Interface relay 3TX70, overall width starting at 6.2 mm:
• Can be used for contact multip lication, potential matching or
as EMC and overvoltage protection.
• Semiconductor variants for applications with high switching
frequency or for switching capacitive loads.
Analog interface converters/isolation amplifiers/ Plug-in relay LZX:
12 transducers 3RS17
• Can be used for contact multip lication, potential matching or
Signal conversion is required, for example, whenever a voltage to switch small loads.
signal has to be converted into a current signal for transmission • Up to 4 changeover co ntacts in one device.
via a long path or a sensor output and control input are incom-
patible. Monitoring relays 3RS10/11, 3UG3, 3RN1
Analog interface converters are particularly suitable for the elec- Temperature monitoring relays 3RS10/11 work in parallel with an
trical isolation or conversion of analog signals, potential distribu- enclosed temperature control loop and are used to monitor a
tion or EMC and overvoltage protection. preset threshold temperature in solid, liquid or gaseous media.
• Microprocessor-controlled and calibrated interface conver- • DIN 3440 certification as "tempe rature limiting or monitoring
ters starting at an overall width of 6.2 mm. devices".
• Very easy commissioning using the DIP switch and integrated • Easy to operate without complicated menu guidance or add-
setpoint encoder. on software.
• All terminals are protected against polarity reversal and short
circuits and can withstand voltages up to 30 V.
■ Overview (Continued)
Monitoring relays 3UG3 are used to monitor electrical and non- Time-delay relays 3RP15 and 3RP20
electrical variables, which cannot be detected directly by an au-
tomation system. The primary task of time-delay relays 3RP15 and 3RP20 is to
delay the starting up of the overall system until the automation
• Monitoring of line supplies for overvoltage or undervoltage, system has reached a defined state or to control real-time-criti-
direction of rotation or asymmetry. cal processes such as on a star-delta connection.
• Monitoring of loads based on power factor or current. • Wide voltage range and multifunction variants.
• Monitoring of fill levels or speeds. • Electronically-optimized hard-gold-plated contacts.
Thermistor motor protection devices 3RN1 monitor the winding Further information:
temperature of motors, which have an integrated PTC sensor.
• Catalog LV 10 Chapter 8
• Certified to ATEX 100a (for gases and dusts).
• Product brochure for Sirius monitoring, time-delay and all-or-
• Fast fault diagnosis thanks to th e indication of wire-break or nothing relays
short-circuit.
• Internet:
• Electronically-optimized output thanks to hard-gold-plated http://www.siemens.com/simirel
contacts.
SIMODRIVE sensor
■ Overview
• Couplings, assembly fittings, cable connectors, and complete
preassembled signal cables are available as accessories for
SIMODRIVE sensor.
• SIMODRIVE sensor built-on encoders can be supplied as
incremental encoders and absolute encoders.
• Incremental encoders:
- Interfaces RS 422 (TTL), 1Vpp and HTL.
- Operating voltage 5 V DC or 10 V to 30 V DC.
• Absolute encoders:
- All absolute encoders are available in single-turn or multiturn
versions.
- SSI (Synchronous Serial Interface) or connection for EnDat,
PROFIBUS DP or DRIVE-CLiQ.
- Encoders with PROFIBUS DP support Class 1 and Class 2
profiles in addition to isochrone mode, internode communi-
cation and application-specific miscellaneous functions.
They are programmable.
• All measuring systems are ava ilable in synchro-flange and
flange-joint versions.
• Measuring systems for detecting distances, angles of rotation
and speed.
• Can be used on machines in a va riety of industry sectors, e.g.,
Further information:
• Catalog NC 60, D21.2, DA65.3, DA65.4
12
production machines, manipulators, machine tools, and spe- • Catalog CA 01
cial machines.
• Internet:
• Can be connected to SIMATIC, SINAMICS, SINUMERIK, http://www.siemens.com/simodrive
SIMOTION, and SIMODRIVE.
■ Overview
SIMOTION D – Compact and integrated in the drive
• Complete machine automation wi th drive control, Motion Con-
trol, technology and PLC functionality on a SINAMICS S120.
• Particularly fast response times.
• A number of performance variants to support scaling.
• Typical areas of application:
- Compact machines
- Distributed automation concepts, e.g., on machines with a
large number of axes
- Modular machines, also as add-ons for SIMOTION P or
SIMOTION C
- For time-critical requirements on coupled axes
SIMOTION C – Modularity and flexibility
• Controller in S7-300 design.
• With integrated drive interfaces for analog or stepper drives
and inputs/outputs.
• Can be expanded with SIMA TIC S7-300 I/O and function mo-
System SIMOTION dules.
• The SIMOTION system is used primarily on machines on • With integrated isochronous PR OFIBUS interfaces for the dis-
which motion control with servo or hydraulic axes dominates. tributed connection of drives or communication with operator
Its main areas of application are on packaging, printing and panels and higher-level controls.
plastics machines as well as in the automation of machines in • Typical areas of application:
the textiles, metalworking, wood, glass, ceramics and stone - Wherever analog or stepper drives are being used, e.g.,
sectors. during retrofitting.
• Principle of the system: To me rge Motion Control with logic - If the range of process signals is very wide.
and technology functions so that all motions, motion-based lo-
gic functions and technology functions such as temperature SIMOTION P– Open for other tasks
control, hydraulic or cam functions can be executed in the • PC-based Motion Control system under Windows XP with real-
same system. time expansion.
• Advantages: • Other PC applications may run in addition to the machine ap-
- No time-critical interfaces between components. plication, e.g., engineering system, Office applications or pro-
- No programming overhead for these interfaces. cess data evaluation.
- Uniform and transparent programming and diagnostics • Drives connected remotely via isochronous PROFIBUS.
familiar from PLC systems.
- Hardware platform can be freely selected: controller, PC or • Supports the use of a variety of Panel PC variants with dis-
integrated directly in the drive. plays of various sizes and operation via keyboard/mouse or
- Simple sequence programming in graphics format with touch screen.
Motion Control Chart. • Typical areas of application:
- Integrated PLC functionality. - Openness of the PC is required.
• SIMOTION system components: - Applications with hardware-based control and visualization.
- SCOUT engineering system: - Applications with extensive data management, analysis and
The features of the engineering system for complete logging.
machine automation include: - Advanced requirements in terms of remote diagnostics and
remote control.
12 MCC (Motion Control Chart) for simple sequence
programming in graphics format; - Central control concept for large numbers of axes.
LAD and CSF for programming PLC tasks, Further information:
ST as text language to simplify the creation of functions and
generation of complex calculations • Catalog PM 10
- Runtime software modules: • Catalog CA 01
A variety of Motion Control and technology functions. • Internet:
Specific selections can be made to adapt the system flexibly http://www.siemens.com/simotion
to the machine.
- Hardware platforms:
A variety of platforms support adaptation to the machine
being used. The compact variant in the drive, the modular
variant in S7-300 design, and the open variant as a pure
software solution on industrial PC are available for selection.
■ Overview
SINUMERIK 840Di
• Fully PC-integrated NC control. Hardware and software open-
ness.
• Used in applications such as simple Motion Control tasks
(positioning and linear interpolation), woodworking, handling,
assembly, machine tools, and applications in the vicinity of
machine tools.
• Comprising an industrial PC, the MCI board and system soft-
ware.
• The drive and I/O are connect ed on the MCI board via the
PROFIBUS DP interface.
• The HMI programming package, the HMI configuration pak-
kages and HMI-Advanced, the standard user interface for
machine tools, are all available as optional HMI modules.
SINUMERIK 840D with
SIMODRIVE 611 digital (SINUMERIK powerline)
• The digital system for the most complex requirements.
SINUMERIK 802 • Can be used in mold and to ol making, in complex mass pro-
• CNC family for simple applications duction in job-shop production and for almost any type of
technology.
• Used primarily in turnin g and milling applications;
solutions in other technologies are also possible. • With up to 10 CNC channels and 31 axes per NCU module,
making it suitable for use in the rotary transfer machines and
• SINUMERIK 802S base line with stepper drives for compact "cyclic machines" (e.g., presses, packaging and printing ma-
and ultra-compact machines. Installation made easy, highly chines) sector.
precise even without measuring systems.
• Scalable NCU software with 2/ 6/12/31 axes for a number of
• SINUMERIK 802C base line with analog drives for increased different NCU modules and correspondingly advanced CNC
dynamics and power. Perfect for retrofitting. Standard drives functionality.
±10 V, suitable for universal use, easy to operate and proven
technology. • Up to 8 NCUs with up to 24 8 axes can be connected via NC
link.
• SINUMERIK 802D/802D base line with digital drives for series
machines. Easy start-up, PROFIBUS for all components. • Special technology functions (e .g., laser machining, handling)
available via compile cycles that can be reloaded in order to
SINUMERIK 810D with support optimum adaptation to the machines and the equip-
SIMODRIVE 611 digital ment of integrated machine series.
• The cost-effective introduction to the future-oriented CNC and • All NCUs with optional PROFIBUS DP interface (master/slave).
drive world for machine tools.
Further information:
• Compact design.
• Catalog NC 60
• In addition to user-friendly CNC functions, it also features up
to 6 SIMODRIVE 611 digital drive controls and 2 or • Internet:
3 SIMODRIVE 611 power supply modules. http://www.siemens.com/sinumerik
• Standard version with optional PROFIBUS DP interface
(master/slave).
12
■ Overview
• Comprising the SICLOCK TM and SICLOCK TS plant central
clocks, radio synchronization units, pulse converters and
driver software for message frame reception.
SICLOCK TM and SICLOCK TS
• Plant central clocks for process synchronization.
• Can be adapted to the proces s quickly and easily by assi-
gning interface and telegram-content parameters via the LCD
on the device.
• Radio synchronization via GPS, DCF77, IRIG B, etc.
• Process synchronization via Ethernet (AUI, ITP and twisted
pair) and 8 outputs (TTY, RS 232, RS 422 and level 0 up to
15 V) or 3 outputs (TTY and RS 422) with message frames,
DCF77 simulation and pulses, IRIG A and B (SICLOCK TS
only).
Further information:
• Siemens AG SICLOCK Hotline
Phone: +49 (9131) 7-28866 Fax: +49 (9131) 7-22977
• A modular time distribution system for process synchroniza- E-mail: siclock@siemens.com
tion incl. radio receiver for GPS and DCF77. • Internet:
• Can be used to synchronize individual PCs or even large http://www.siemens.de/siclock
plants with multiple redundancy. http://www.siemens.com/siclock
• Can be connected to SIMATIC S7, S5, PCS 7, PCs, compu-
ters, etc. via Ethernet (SIMATIC NET or NTP).
• Individual connections with as ynchronous data transmission,
pulses and FO connections.
SITOP power
■ Overview
SITOP
• For 24 V standard and complex applications.
• Variants available for other voltage ranges.
• Versatile functionality and modular design.
• Add-on modules for signaling func tions, line-supply buffering,
safe redundancy, and fault diagnosis.
• DC UPS modules and 24 V battery modules for power loss
ride-through.
12 LOGO!Power
• Compact power supplies based on LOGO! logic module
design
• Output voltages 5, 12, 15, 24 V for a wide variety of possible
applications.
• Compact with versatile functionality.
Further information:
• Catalog KT 10.1
• High efficiency of approx. 90%.
• Internet:
• Quick, easy and inexpensive installation. http://www.siemens.com/sitop
• Requires little space thanks to high power density.
• Exact output voltage 24 V DC.
• Low residual ripple of <0.4%.
• Integrated short-circuit protec tion, additional fusing not
required.
• Safe electrical isolation.
• Meets the requirements of national and international stan-
dards.
■ Overview
• Supplied by the meter, other lengths available on request.
• The following products are available:
- MOTION-CONNECT 500,
primarily for fixed installation.
- MOTION-CONNECT 500 PLUS,
suitable for trailing and resistant to mineral oils (except bio-
oils and cutting oils).
- MOTION-CONNECT 700,
ideal for linear motors and machines with complex mechani-
cal requirements.
- MOTION-CONNECT 800,
meets all requirements for use in cable carriers on machine
tools and production machines.
Further information:
• Catalog NC 60
• Catalog D21.2
• Catalog DA 65.3
• Catalog CA 01
• Preassembled cables, suitable for use in all types of machine
tools and production machines. • Internet:
http://www.siemens.com/automation/mall
• High quality and system-tested optimized function.
• Power, signal and DRIVE-CLiQ (SINAMICS) cables can be
ordered as preassembled MOTION-CONNECT cables.
■ Overview
• Tested to IEC 255-5.
• Supports multichannel communi cation with higher-level
control systems based on standardized remote control
protocols IEC 60870-5-101 and IEC 60870-5-104 as well as
SINAUT 8-FW, DNP V3.0, Telegyr 800, Telegyr 8979; with
IEC 60870-5-101 and IEC 60870-5-104 also dual-channel/
redundant communication.
• Connection of substations via telecontrol protocols
IEC 60870-5-101 and DNP V3.0; medium: RS232, RS485.
• Connection of protection device s and field control stations (in
particular SIPROTEC), transformer controllers and digital
transducers (SIMEAS T) with the IEC 60870-5-103 protocol;
medium: FO, RS232, RS485.
• Connection of additional field devices for power engineering,
e.g., via PROFIBUS DP (SIMEAS Q, SIMEAS P, SIMOCODE,
12
SU200) and DNP V3.0 and Modbus.
• Time synchronization for the entir e system with DCF77, GPS or
telecontrol protocol.
• Telecontrol and substation cont rol unit based on the SIMATIC • Real-time detection with 1 ms resolution.
S7-400 for monitoring and controlling distributed processes. • Web-based diagnostics and testing with SICAM Diamond.
• Can be used in power transmissi on and distribution for the au- • User-friendly configuration of the power process with SICAM
tomation of medium and high-voltage systems. plusTOOLS for eRTU.
• Excellent voltage endurance and electromagnetic compatiblity. • Graphics-based configuration of power process automation
• Central process connection with SICAM I/O modules. (system interlock, switching sequences, automatic functions)
• Self-monitoring inputs, protected command outputs. with CFC and special system-tested function blocks.
• Technical specifications: Further information:
- Insulation 2.5 kV • Catalog SICAM 2.4.1
- Surge voltage 5 kV
- Wide-range inputs: • Internet:
24 V to 60 V DC, 110 V to 125 V DC http://www.ptd.siemens.com
■ Overview
• Modular, high-performance compact telecontrol unit with a
functional scope of up to 300 process inputs/outputs.
• Real-time detection with 10 ms resolution.
• Connection of protection de vices via IEC 60870-5-103 and
MODBUS RTU.
• User-programmable automation functions with STEP 7-micro.
• Functions:
- Single messages and double messages; transmission of
message frames with or without time stamp.
- Processing of counting pulses (max. 20 Hz).
- Processing of measured values, threshold values.
- Command output as pulse commands with 1-in-n monitoring
and command deactivation.
- Analog setpoint output.
- Time-of-day management with synchronization via message
frames from the master terminal.
- Baud rate can be set between 300 and
9600 bps.
■ Overview
• Up to 50 process inputs/outputs for:
- Single messages
- Double messages
- Measured values
- Single commands
- Double commands
- Counting pulses
• Event detection with 10 ms resolution.
• Functions:
- Up to 24 single messages
- Up to 4 counting pulses (max. 20 Hz)
- Up to 16 measured values
12 - Up to 16 command outputs as pulse command or persistent
command; output times can be programmed
- IEC 60870-5-101 protocol, unbalanced mode
- Baud rate: 300 to 9600 bps
Further information:
• Catalog SICAM 2.3.1
• Compact telecontrol unit for processing process information • Internet:
and communicating with the power system master terminal via http://www.ptd.siemens.com
a secure IEC 60870-5-101 telecontrol protocol.
■ Overview
• Accuracy +/- 2 ms.
• Buffer memory on module for 200 changes in state with time
of day.
• Increased protection against electromagnetic interference
(e.g., in the event of lightning strikes or overvoltage).
• Technical specifications:
- Time resolution 1 ms
- Insulation 2.5 kV
- Surge voltage 5 kV
- 32 inputs
- Input voltage
19 V to 72 V DC or
110 V to 125 V DC
• Configuration using
SICAM plusTOOLS.
Further information:
• Catalog SICAM 5.2.1
• Internet:
• Digital inputs with interrupt ca pability for detecting time-criti- http://www.ptd.siemens.com
cal processes.
• Real-time resolution 1 ms.
■ Overview
• Isolated analog input with in terrupt capability for detecting
measured values from transducers.
• Resolution
12 bits + sign.
• Programmable measuring ranges.
• Conversion time 30 ms,
effects of line frequency suppressed.
• Technical specifications:
- Insulation 2.5 kV
- Surge voltage 5 kV
- 32 channels
- Current inputs
0.5 to 24 mA DC
- Voltage inputs
0.5 V to 10 V DC
• Configuration using
SICAM plusTOOLS.
Further information:
• Catalog SICAM 5.2.2
• Internet:
http://www.ptd.siemens.com
■ Overview
• For time synchronization in an S7-400.
• Synchronization of CPU and SICAM function modules.
• Setting via DCF77 or GPS time signal receivers.
• Application:
e.g., error message detection system together with digital
input SICAM DI 32.
• Comprising SICAM MCP modu le and example FBs for
SIMATIC S7-400.
• Configuration using
SICAM plusTOOLS.
Further information:
• Internet:
http://www.ptd.siemens.com
12
s
■ Overview
• System power supply with incr eased demands on availability
and noise immunity.
• Wide-range input.
• 20 A short-circuit proof.
• 20 ms bridging if the power supply is interrupted.
• Technical specifications:
- Insulation 2.5 kV
- Surge voltage 5 kV
- Input voltage
24 V to 60 V DC or
110 V to 230 V UC
• Configuration using
SICAM plusTOOLS.
Further information:
• Catalog SICAM 5.1.1
• Internet:
http://www.ptd.siemens.com
12
12
13/2 Training
13/3 Certified Automation Competence
13/5 Courses Offered
SIMATIC Industrial Automation
Systems
13/7 Courses Offered
SIMATIC HMI, PC-based Automation,
SIMADYN/SIMATIC TDC, Machine
Vision,
13/8 SIMATIC S7 Training Case
S7-300 TIA
13/8 SIMATIC S7 Training Case
S7-400
13/9 SIMATIC S7 Training Case
S7-300F
13/9 SIMATIC S7 Training Case
S7-400F/H
13/18 Index
Siemens ST 70 · 2005
Appendix
Training
Wide variety
■ Training is decisive for your success
With a total of approx. 300 local attendance courses, we train the
SITRAIN® - the Siemens Training for Automation and Industrial complete range of A&D products and a large portion of the sys-
Solutions - provides you with comprehensive support when solv- tem solutions from I&S. Telecourses, teach-yourself software and
ing your tasks. seminars presented on the Web supplement our classical range
Training by the market leader in automation, plant installation of courses.
and support permits you to make your decisions with certainty Close to our customers
and full command. Especially where the optimum and efficient
use of products and plants are concerned. You can eliminate de- The distance is short. You can find us approx. 60 times in Ger-
ficiencies in existing plants, and exclude expensive faulty plan- many, and worldwide in 62 countries. You wish to have individual
ning right from the beginning. training instead of one of our 300 courses? No problem: we will
provide a program tailored exactly to your personal require-
All in all, this represent an enormous gain for your company: ments. Training can be carried out in our Training Centers or at
shortened startup times, optimized plant components, your company.
faster troubleshooting, reduced down times. In other words,
increased profits and lower costs.
■ The right mixture: blended learning
Blended learning is understood to be the combination of various
training media and sequences. For example, a local attendance
course in a Training Center can be optimally supplemented by a
teach-yourself program as preparation or follow-up. Further-
more, SITRAIN utilizes supported online training for live instruc-
tion on the Internet at agreed times.
The right mixture is the solution. Therefore blended learning
can convey complex topics well, and train networked think-
ing. Additional effect: reduced travelling costs and periods
of absence through training sequences independent of loca-
tion and time.
Tasks Tasks
• Professional installation an d connection of programmable • Professional installation and connection of programmable
logic controllers, program modifications, troubleshooting logic controllers, program modifications, troubleshooting
• Commissioning of distributed I/Os (PROFIBUS DP)
Skills of a PLC Technician
• Commissioning of a drive
They must know the design and principle of operation of a PLC • Commissioning of an HMI device (TP 170B)
as well as the basic operations of the relevant programming lan-
guage. They must know how to install and connect PLCs, check Skills of a Siemens Automation Technician
the inputs and outputs, and be able to assist with commissioning They must be familiar with the design and principle of operation
if instructed. of a PLC and know how to implement the basic operations of
the relevant programming language, as well as install and con-
nect PLCs, check the inputs and outputs, and be able to imple-
ment the commissioning procedure.
Application programming
and program documentation
HMI visualization
PLC fundamentals
PROFIBUS, communication
Drive systems 13
100% 50% 0% to know to know 0% 50% 100%
how to do
To know-how to do something: to be familiar with a subject and/or be able to allocate it within a greater context.
Can do something: to apply one's knowledge and skills to solve tasks.
Implementation of PROFIBUS DP
Implementation of drives
Use of HMI systems
to know to know
13 how to do 0% 50% 100%
■ PC-based Automation
SIMATIC S7, PC-Based Control with WinAC ✔ ✔ ✔ ✔ 2 days ST-7WINAC 13
■ SIMADYN Control System/SIMATIC TDC Automation System
SIMADYN D / STRUC G - Introduction for Service Engineers ✔ ✔ ✔ 5 days SD-SD1
SIMADYN D / STRUC G - Introduction for Engineering and Commissioning ✔ ✔ 5 days SD-SD2
SIMADYN D - Commissioning DC Drives ✔ 5 days SD-SD3
Configuring D7-SYS with CFC - for SIMADYN D/SIMATIC TDC ✔ ✔ 3 days SD-TDCCFC
Communication in D7-SYS - SIMADYN D/SIMATIC TDC Fundamentals ✔ ✔ 2 days SD-TDCKOM
■ Machine Vision
Vision Sensor SIMATIC VS 710
SIMATIC VS 710 under ProVision in Factory Automation ✔ ✔ ✔ ✔ 3 days ST-VS710
Machine Vision Add-On Training ✔ ✔ 1 day ST-VS710A
Vision Sensor SIMATIC VS 720
SIMATIC VS 720 in Factory Automation ✔ ✔ ✔ ✔ 2 days ST-VS720
■ Application ■ Application
The training system is used to train programming, operation and The training cases are used to train programming, operation and
commissioning of programmable logic controllers within Totally commissioning of programmable logic controllers in practice.
Integrated Automation in practice.
■ Design ■ Design
The training system consists of a SIMATIC S7-300 PLC, a The training devices consist of a SIMATIC S7-400 PLC and a
TP170B HMI system and a simulator. The PLC is installed into a simulator. The PLCs are installed into a case for transporting.
case for transporting.This case includes: This case includes:
• DIN rail • Subrack
• Load current supply PS 307 • Cable duct
• CPU 315-2DP • Load current supply PS 407 20A
• Digital input module SM 321, DI 32 x DC 24 V • CPU 412-1
• Digital input/output module SM 323, DI 8, DO 8 • Memory Card
• Digital output module SM 322, DO 32 x DC 24 V/0,5 A • Digital input modules SM 421, DI 32 x DC 24 V
• Analog input module SM 331, AI 2 x 12 Bit plus VZ • Digital output modules SM 422, DO 32 x DC 24 V/0,5 A
• Terminal strips for digital signals • Analog input module SM 431, AI 8 x 13 Bit
• Terminal strip/connector block for analog signals • SITOP Power 5 A
• SIMATIC S7 simulator • Terminal strips for digital signals
• 1 ET 200S with • Terminal strip/connector block for analog signals
- 1 interface module IM 151,
- 1 terminal block TM-P 15S23-A1, • SIMATIC S7 simulator
- 1 power module PM-E DC 24 V,
- 4 terminal blocks TM-E 15S24-A1,
- 2 digital input modules 4 x DC 24 V,
- 2 digital output modules,
■ Technical specifications
- 1 terminal strip DI/DO 37-pole, Degree of protection to IP00
DIN VDE 0470
• TP170B color Part 1/EN 60529/IEC 529
• Connection cable PROFIBUS DP for the TIA training system Permissible ambient temperature 0 to +60 °C
13 ■ Technical specifications Dimensions in mm (W x H x D) 665 x 565 x 385
Weight approx. 30 kg
Degree of protection to IP00
DIN VDE 0470
Part 1/EN 60529/IEC 529 ■ Ordering data Order No.
Permissible ambient temperature 0 to +50 °C Training device S7-400 6ZB2 310-0BL01
with CPU 412-1 (96 KB)
Dimensions in mm (W x H x D) 520 x 410 x 350 complete incl. simulatorA)
Weight approx. 18 kg Short title: TG-S7-4121
Training device S7-400 6ZB2 310-0BN01
■ Ordering data Order No. with CPU 412-2DP
complete incl. simulatorA)
Training device S7-300 with 6ZB2 310-0BW00 Short title: TG-S7-4122
CPU 315-2DP, complete with
ET200S, TP 170B and simulatorE) Design as above
except:
Short title: TG-S7-315TIA • 1 CPU 412-2 DP
E) Subject to export regulations: AL: N and ECCN: 5D002ENC3
(instead of CPU 412-1)
A) Subject to export regulations: AL: N and ECCN: EAR99H
■ Application ■ Application
The training case is used to train programming, operation and The training case is used to practice the practical aspects of
commissioning of fail-safe programmable logic controllers in programming, operation and commissioning of fail-safe and
practice. fault-tolerant programmable logic controllers.
■ Design ■ Design
The training device consists of a SIMATIC S7-300F PLC, The training device consists of a SIMATIC S7-400F/H PLC with 2
EMERGENCY-OFF pushbuttons, contactors, door switches and CPUs.The PLCs are installed into a case for transporting. This
alarm displays. The PLC is installed into a case for transporting. case includes:
This case includes: • PS 307 power supply units
• SIMATIC S7 DIN rail • IM 153 header modules
• PS 307 power supply unit • DI module incl. bus unit
• CPU 315F central processing unit • DO module incl. bus unit
• Bus connector • F-DI module incl. bus unit
• IM 151 header module • F-DO module incl. bus unit
• Power module incl. terminal module • Subrack
• F-DI modules incl. terminal modules • PS 407 power supply units
• F-DO module incl. terminal module • S7-400 CPU 417H cent ral processing units
• F-Power module • Communications processors
• DI module incl. terminal module • Communication modules incl. FOC
• DO module incl. terminal module
• EMERGENCY-OFF
• Reset
• Contactors
• Mechanics
CE mark
■ CE mark ■ Notes for machine manufacturers
The electronic products described in this catalog comply with The SIMATIC automation system is not a machine within the con-
the requirements and protection objectives of the following EU text of the EU machine guidelines. For SIMATIC, a conformity
guidelines and with the harmonized European standards (EN) declaration with respect to the EU machine guidelines
which have been published for programmable controllers in the 89/392/EMC is not available.
official Journal of the European Union:
The EU guideline for machines 89/392/EMC specifies the re-
• 89/336/EWG “Electromagnetic Compatibility” quirements for a machine. A machine is understood for the pur-
(EMC guideline). poses of this guideline to be a combination of interconnected
• 73/23/EWG “Electrical Equipment for Use Within Specific parts or mechanisms (see also EN 292-1, Paragraph 3.1).
Voltage Limits” (low voltage guideline). SIMATIC is part of the electrical equipment of a machine and
We have declarations of conformity available for the responsible must therefore be included in the conformity declaration proce-
authorities. dure by the machine manufacturer.
The SIMATIC products are designed for operation in industrial The EN 60204-1 standard (safety of machines, general require-
environments and comply with the following requirements: ments for the electrical equipment of machines) is applicable to
the electrical equipment of machines.
Noise emissions: EN 50081-2: 1993
Noise immunity: EN 50082-2: 1995 The following table should be of assistance with the conformiy
declaraton and shows which criteria of EN 60204-1 (as of June
The products can also be used in the domestic environment 1993) apply for SIMATIC:
(household, business and trade area, small plants) with individ-
ual approval:
EN 60204-1 Topic/criterion Notes
Emitted interference: Individual approval
13 Immunity: EN 50082-1: 1992
For household use an individual approval from the respective
Paragraph 4 General
requirements
The requirements are met when
the equipment is assem-
bled/installed in accordance with
national authority or testing body is required as far as emitted in- the installation guidelines.
terference is concerned. In Germany this approval is issued by Please note the relevant informa-
the Federal Post and Telecommunications Office and its subsi- tion in the manuals.
daries. Paragraph 11.2 Digital input/output The requirements are met
For the installation and operation of the products described in interfaces
this catalog, the installation guidelines described in the manuals Paragraph 12.3 Programmable The requirements are met when
and the important notes concerning installation in cabinets and equipment the equipment is installed in
concerning the use of shielded cable must be complied with. lockable cabinets to protect
against alteration of the memory
contents by unauthorized per-
sons
Paragraph 20.4 Voltage tests The requirements are met
13
■ Overview
At
www.siemens.com/automation/partner
you can find details of Siemens contact partners worldwide re-
sponsible for particular technologies.
You can obtain in most cases a contact partner for
• Technical Support,
• Spare parts/repairs,
• Service,
• Training,
• Sales or
• Consultation/engineering.
You start by selecting a
• Country,
• Product or
• Sector.
By further specifying the remaining criteria you will find exactly
the right contact partner with his/her respective expertise.
13
13
.I
■ Service On Site
With Service On Site we offer
In the face of harsh competition you need optimum conditions to
services for startup and mainte-
keep ahead all the time:
nance, essential for ensuring
A strong starting position. A sophisticated strategy and team for
system availability.
the necessary support - in every phase.
Service & Support from Siemens provides this support with a In Germany
complete range of different services for automation and drives. 0180 50 50 444 1)
In every phase: from planning and startup to maintenance and
upgrading.
Our specialists know when and where to act to keep the produc-
tivity and cost-effectiveness of your system running in top form.
■ Repairs and Spare Parts
■ Online Support In the operating phase of a ma-
The comprehensive information chine or automation system we
system available round the provide a comprehensive repair
clock via Internet ranging from and spare parts service ensur-
Product Support and Service & ing the highest degree of oper-
Support services to Support ating safety and reliability.
Tools in the Shop.
In Germany
http://www.siemens.com/ 0180 50 50 448 1)
automation/service&support
■ Technical Consulting
Support in the planning and de-
signing of your project from de-
13
tailed actual-state analysis,
target definition and consulting
on product and system ques-
tions right to the creation of the
automation solution. 1)
13 ”Functions &
Samples“
Adaptable blocks for accelerating your developments
■ Overview
Software types Certificate of license
Software requiring a license is categorized into types. The Certificate of License (CoL) is the licensee's proof that the
The following software types have been defined: use of the software has been licensed by Siemens. A CoL is
• Engineering software required for every type of use and must be kept in a safe place.
• Runtime software Downgrading
Engineering software The licensee is permitted to use the software or an earlier ver-
sion/release of the software, provided that the licensee owns
This includes all software products for creating (engineering) such a version/release and its use is technically feasible.
user software, e.g. for configuring, programming, parameteriz-
ing, testing, commissioning or servicing. Delivery versions
Data generated with engineering software and executable Software is constantly being updated.
programs can be duplicated for your own use or for use by third- The following delivery versions
parties free-of-charge. • PowerPack
Runtime software • Upgrade
This includes all software products required for plant/machine can be used to access updates.
operation, e.g. operating system, basic system, system expan- Existing bug fixes are supplied with the ServicePack version.
sions, drivers, etc.
PowerPack
The duplication of the runtime software and executable pro-
grams created with the runtime software for your own use or for PowerPacks can be used to upgrade to more powerful software.
use by third-parties is subject to a charge. The licensee receives a new license agreement and CoL
(Certificate of License) with the PowerPack. This CoL, together
You can find information about license fees according to use in with the CoL for the original product, proves that the new soft-
the ordering data (e.g. in the catalog). Examples of categories of ware is licensed.
use include per CPU, per installation, per channel, per instance, A separate PowerPack must be purchased for each original
per axis, per control loop, per variable, etc. license of the software to be replaced.
Information about extended rights of use for parameteriza-
tion/configuration tools supplied as integral components of the Upgrade
scope of delivery can be found in the readme file supplied with An upgrade permits the use of a new version of the software on
the relevant product(s). the condition that a license for a previous version of the product
is already held.
License types The licensee receives a new license agreement and CoL with
Siemens Automation & Drives offers various types of software the upgrade. This CoL, together with the CoL for the previous
license: product, proves that the new version is licensed.
• Floating license A separate upgrade must be purchased for each original license
of the software to be upgraded.
• Single license
• Rental license ServicePack
• Trial license ServicePacks are used to debug existing products.
ServicePacks may be duplicated for use as prescribed accord-
Floating license ing to the number of existing original licenses.
The software may be installed for internal use on any number of License key
devices by the licensee. Only the concurrent user is licensed.
The concurrent user is the person using the program. Use be- Siemens Automation & Drives supplies software products with
gins when the software is started. and without license keys.
A license is required for each concurrent user. The license key serves as an electronic license stamp and
Single license is also the "switch" for activating the software (floating license,
rental license, etc.).
Unlike the floating license, a single license permits only one
installation of the software. The complete installation of software products requiring license
keys includes the program to be licensed (the software) and the 13
The type of use licensed is specified in the ordering data and license key (which represents the license).
in the Certificate of License (CoL). Types of use include for
example per device, per axis, per channel, etc.
Detailed explanations concerning license conditions can be
One single license is required for each type of use defined. found in the “Terms and Cond itions of Siemens AG” or under
http://www.siemens.com/automation/mall
Rental license (A&D Mall Online-Help System)
A rental license supports the "sporadic use" of engineering
software. Once the license key has been installed, the software
can be used for a specific number of hours (the operating hours
do not have to be consecutive).
One license is required for each installation of the software.
Trial license
A trial license supports "short-term use" of the software in a non-
productive context, e.g. for testing and evaluation purposes.
It can be transferred to another license.
■
To Your adress
Siemens AG
A&D PT 5
ST 70-2005/ Mr. Fregien Name
Gleiwitzer Str. 555
D-90475 Nürnberg
Job
Fax: ++49 (911) 895-4837
Company/Department
Street/No.
Postal code/City
Tel. No./Fax
■ We invite you to grade our catalog on a point system from 1 (= good) to 6 (= poor):
Do the contents of the catalog live up to your Do the technical details meet your expectations?
expectations?
Is the information easy to find? How would you assess the graphics and tables?
13
To:
Fax No.
Subject to the General Conditions of Supply and Delivery specified in your sales partner’s catalog and/or price list.
Company/Department Street/No.
Contact person
Date Signature
Siemens AG Order-No.
Automation and Drives E86060-K4670-A111-A9-7600
Industrial Automation Systems KG 1104 60.0 OL 640 En/501068 / IWI: TSTJ
Postfach 48 48 Printed in the Federal Republic of Germany
90327 NÜRNBERG
FEDERAL REPUBLIC OF GERMANY
A&D/3U/En 28.09.04
Catalog ST 70 · 2005
Catalog ST 70 · 2005
Automation and Micro Automation
Products for Totally Integrated
simatic
The information provided in this catalog contains descriptions
or characteristics of performance which in case of actual use
do not always apply as described or which may change as a
result of further development of the products. An obligation
to provide the respective characteristics shall only exist if
expressly agreed in the terms of contract. Availability and
technical specifications are subject to change without notice.
s
Siemens AG
s
Automation and Drives
Industrial Automation Systems
Postfach 4848
Products for
90437 NÜRNBERG
FEDERAL REPUBLIC OF GERMANY
Totally Integrated Automation
www.siemens.com/automation Order No.: E86060-K4670-A111-A9-7600 and Micro Automation