Zws240paf
Zws240paf
with
improved output
power ZWS150PAF/L
ZWS240PAF
ZWS150PAF
2
Y
E
A
R
S
warranty
s ks
その他 その他
■ Features
医 療 計 測
医 療 F A
計 測 半導体
F A その他
半導体 その他
■ Model naming method
h ph Complies the standard of the harmonics
その他 その他
current limit ZWS 150PAF-24/□ □
Option 1
Blank: PCB type
●P
ower supply for motor drive in mechatronics prod- L: L-shape metal plate type
ucts: Applicable for 24V pulse load A: With cover
Option 2
●U
ltracompact and high power: Peak power of twice
Blank: Molex connector
the value of average power その他 その他 J: JST connector
f-a pf-a ● Worldwide input voltage range: 85-265VAC
T: Terminal block(vertical)
S: Terminal block(horizontal)
コンピュータ コンピュータ
通 信 通 信 F A 半導体
F A 半導体
●C
omplies the harmonics current limit standard: Built- Nominal output voltage
in active filter Active filter
● Small leak current: Convenient for use in combina- Peak current
k-a hk-a tion with power supply for logic (use of multiple Nominal output voltage
Series name
units of power supply)
●A
wide variety of optional items/Harmonics current
■ Conformity to RoHS Directive
limiter
This means that, in conformity with EU Directive 2002/95/
ws hws その他 その他 EC, lead, cadmium, mercury, hexavalent chromium, and
specific bromine-based flame retardants, PBB and PBDE,
■ Applications
コンピュータ コンピュータ
通 信 通 信
医 療 医 療
計 測 計 測
F A F A
半導体 半導体
have not been used, except for exempted applications.
ォーマット
フォーマット
コンピュータ コンピュータ
通 信 医 療
通 信 計 測
医 療 計 測
F A 半導体
F A 半導体
150W 240W
Output Voltage
Current(Peak) Model Current(Peak) Model
24V 6.3A(12A) ZWS150PAF-24/J 10A(20A) ZWS240PAF-24/J
lp dlp 36V 4.2A(8A) その他 その他
ZWS150PAF-36/J 6.7A(13.3A) ZWS240PAF-36/J
コンピュータ 通 信48V
コンピュータ 医 療
通 信 3.1A(6A)
計 測
医 療 計 測
F A F AZWS150PAF-48/J
半導体 半導体 5A(10A) ZWS240PAF-48/J
ZWS
-PAF
コンピュータ コンピュータ
通 信 医 療
通 信 計 測
医 療 計 測
F A 半導体
F A 半導体
(*1) Operating period at peak output current is less than 10 sec. (Duty (*7) No load - full load (maximum power), constant input voltage.
< 0.35)
(*8) Constant current limit with automatic recovery. Avoid to operate at
(Average output power and current is less than maximum output
overload or dead short for more than 30 seconds.
power and current.)
For peak load derating method, please refer to instruction manual (*9) OVP circuit will shutdown output, manual reset. (Line recycle)
for details. (*10) Measured by each measuring method of UL, CSA, EN and DENAN
(*2) At 100/200VAC and maximum output power, Ta = 25℃. (at 60Hz).
(*3) For cases where conformance to various safety specs (UL, CSA, (*11) At standard mounting method, Fig B.
EN) are required, to be described as 100-240VAC, 50/60Hz on -Load(%) is percent of maximum output load, do not exceed derating
name plate. in both maximum output current and power.
-For other mountings, refer to derating curve.
(*4) Not applicable for the in-rush current to noise filter for less than
-When forced air cooling, refer to derating curve.
0.2ms.
(*12) As for DENAN, built to meet at 100VAC.
(*5) Please refer to Fig A for measurement of line & load regulation and
output ripple voltage. (*13) 85-265VAC, no load - full load, constant load.
(Measure with JEITA RC-9131 probe.)
(*6) 85-265VAC, constant load.
ZWS RSEL-2006W
-PAF Please refer to "TDK-Lambda
EMC Filters" catalog.
(*1) Forced air cooling with air velocity more than 1.5m/s (measured at component side of PCB, ●Recommended EMC Filter
air must flow through component side)
(*2) Operating period at peak output current is less than 10sec. (Duty < 0.35)
(Average output power and current is less than Maximum output power and current.)
For peak load derating method, please refer to instruction manual for details.
(*3) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as
100-240VAC, 50/60Hz on name plate.
(*4) At 100/200VAC and maximum output power, Ta = 25℃.
(*5) At standard mounting method A, and other mountings B, C, D, E. RSEL-2006W
- Load(%) is percent of maximum output load, do not exceed derating in both maximum output Please refer to "TDK-Lambda
current and power. EMC Filters" catalog.
(*6) Output derating for cold start up at Ta = - 10℃ for input voltage : 85VAC 80%, 90VAC 86.7%, 100-265VAC 100%.
No output derating for input voltage is required after start up for one second.
(*7) 85-265VAC, Full load.
ZWS
-PAF
LEAD CUT
LESS THAN 3mm 198±0.5
1
80±1
J
1 3
OUTPUT
LEADLESS
CUT THAN 3mm
ORDER TO CONFORM THE VIBRATION SPEC.
(61)
4
198±0.5 5
(48.9)
(40.7)
6
198±0.5
OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT
VOLTAGE SEE NOTE F ARE SHOWN HERE IN ACCORDANCE WITH THE
SEE NOTE E VOLTAGE
ADJUSTMENT SEE NOTE F SPECIFICATIONS.
SEE NOTE E ADJUSTMENT C. COUNTRY OF MANUFACTURE WILL BE SHOWN HERE.
5
COMPONENT SIDE
5
37±1 5 SEE NOTE F 4-NOTE A D. TO KEEP THE DISTANCE MORE THAN 4m/m BETWEEN
70±0.5
COMPONENT SIDE
5 3
(194.3)
J J
70±0.5
1 1 3
80±1
(unit : mm)
3
(61)
INPUT
2 4
E. FG IS FOR SAFETY GROUND CONNECTION.
208±1
3 5
(48.9)
CONNECTORS USED
1
OUTPUT
(61)
F. REMOTE ON/OFF CONTROL CONNECTOR (CN2,CN52)
(40.7)
4 6
NAME PLATE
5
(48.9)
: B2B-XH-AM (J.S.T.)
(40.7)
PART DESCRIPTION PART NAME MANUFACTURER QTY
6
PIN HEADER
37±1 (OUTPUT SIDE CN51) B6P-VH
5 J.S.T. 1 4-NOTE A 001T-P0.6 (J.S.T.)
5
SEE NOTE D
37±1 5 (194.3) 4-NOTE A HAND CRIMPING TOOL : YC-110R OR YRS-110
MATCHING HOUSINGS & PIN. SEE NOTE D MANUFACTURER : J.S.T.
* NOT INCLUDED WITH THE PRODUCT. (194.3)
208±1
SOCKET HOUSING (CN1) VHR-5N J.S.T. 1 208±1 NAME PLATE
NAMESEE
PLATE
NOTES B&C
SOCKET HOUSING (CN51) VHR-6N J.S.T. 1 SEE NOTES B&C
TERMINAL PINS (CN1, CN51) SVH-21T-P1.1
5 J.S.T. 9 220±0.5
2-SEE NOTE A
4.5
HAND CRIMPING TOOL : YC-160R MANUFACTURER : J.S.T.
27.5 7.5
NOTES
46±1
4.5
ARE FOR CUSTOMER CHASSIS MOUNTING. SCREW
MUST NOT PROTRUDE INTO POWER SUPPLY BY
5 220±0.5 MORE THAN 6mm.
2-SEE NOTE A
5 2-SEE NOTE B 220±0.5 2-SEE NOTE B B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (3) ARE FOR
4.5
(205.3)
4.5
ING SCREW.)
27.5 7.5
20
2-SEE NOTE B
3
SEE NOTE E
2-SEE NOTE B 1
FACTURE ARE SHOWN HERE IN ACCORDANCE WITH
THE SPECIFICATIONS.
D: FG IS FOR SAFETY GROUND CONNECTION.
JL
40±0.5
60±0.5
2-SEE NOTE B
INPUT
2-SEE NOTE B SEE NOTE E:
E REMOTE ON/OFF CONTROL CONNECTOR (CN2, CN52)
2
90±1
1
(205.3) 3
(205.3) 5
4-NOTE A
2-NOTE B
(53.9)
6
(45.7)
4-NOTE A
2-NOTE B VOLTAGE ADJUSTMENT
OUTPUT
SEE NOTE MATCHING HOUSING : XHP-2 (J.S.T.)
B
SEE NOTE D
45
JL JL
VOLTAGE ADJUSTMENT SEE NOTE B
SEE NOTE D SXH-001T-P0.6 (J.S.T.)
SEE NOTE E
25
SEE NOTE E
5
5 3 1 FACTURER : J.S.T.
60±0.5
INPUT5 220±0.5 2
90±1
1 3
CONNECTORS USED
3
40±0.5
COMPONENT SIDE
60±0.5
INPUT 230±1
(66)
2 4
90±1
3 5
(53.9)
COMPONENT SIDE NAME PLATE PART DESCRIPTION PART NAME MANUFACTURER QTY
4.5
6
(66)
4
(45.7)
5
OUTPUT
(53.9)
4.5
SEE NOTE C
(45.7)
OUTPUT
45
5 220±0.5
230±1
MATCHING HOUSINGS & PIN.
5 220±0.5 * NOT INCLUDED WITH THE PRODUCT.
230±1 NAME PLATE SOCKET HOUSING (CN1) VHR-5N J.S.T. 1
NAMESEE
PLATE
NOTE C
5 SOCKET HOUSING (CN51) VHR-6N J.S.T. 1
2-SEE NOTE A
220±0.5 SEE NOTE C (unit : mm)
4.5
4.5
NOTES
5 220±0.5
2-SEE NOTE5A A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6)
220±0.5 2-SEE NOTE B ARE FOR CUSTOMER CHASSIS MOUNTING. SCREW
4.5
4.5
20
VOLTAGE ADJUSTMENT
4.5
2-SEE NOTE B
JA
MANUFACTURE ARE SHOWN HERE IN ACCORDANCE
2-SEE NOTE B
1
40±0.5
4-SEE NOTE A
60±0.5
(205.3)
2
90±1
INPUT
3 WITH THE SPECIFICATIONS.
4-SEE NOTE
2-SEE A B
NOTE
1
SEE NOTE(205.3)
D
4
2-SEE NOTE B
(53.9)
SEE NOTE D
4.5
SEE NOTE B
45
SEE NOTE B
CONNECTORS USED
25
40±0.5 15
JAJA
1
60±0.5
5 3
5 220±0.5 2
90±1
INPUT
3
1
60±0.5
230±1 2 4
90±1
INPUT 5
3
(66)
1
(53.9)
4.5
NAME PLATE
4 6
5 OUTPUT PIN HEADER (OUTPUT SIDE CN51) B6P-VH J.S.T. 1
(66)
(45.7)
(53.9)
4.5
5 220±0.5
5 230±1
220±0.5 SOCKET HOUSING (CN51) VHR-6N J.S.T. 1
230±1
NAME PLATE TERMINAL PINS (CN1, CN51) SVH-21T-P1.1 J.S.T. 9
NAMESEE
PLATE
NOTE C (unit : mm) HAND CRIMPING TOOL : YC-160R MANUFACTURER : J.S.T.
SEE NOTE C
8.6
COMPONENT SIDE TERMINAL COVER
D. TO KEEP THE DISTANCE MORE THAN 4m/m
SEE NOTE F
8.6
70±0.5
80±1
8.6
INPUT
10
70±0.5
10
OUTPUT CHASSIS.
80±1
(61)
8.6
T T
INPUT
10
10
OUTPUT E. FG IS FOR SAFETY GROUND CONNECTION.
(61)
(48)
3-M4 F. REMOTE ON/OFF CONTROL CONNECTOR
(41)
2-M4
(48)
3-M4 (CN2, CN52) : B2B-XH-AM (J.S.T.)
(41)
2-M4 *CN2 IS NORMALLY SHORTED BY JM-2W-96(J.
S.T.)
5
4.5 4.5
NAME PLATE 5 220±0.5
220±0.5
A A 5
27.57.5 7.5
2−SEE
2−SEE NOTE
NOTE
4.5
SEE NOTE C
20 20
NAME
NAME PLATE
PLATE
27.546±17.5
4.5
4.5 4.5
50/60Hz
ZWS150PAF-
ZWS150PAF- 2-SEE
2424
/TL/TL
OUTPUT:2.4 V = 8.3 AC
NOTE A
US
46±1
46±1
27.5 7.5
4.5
4.5
50/60Hz
50/60Hz BARC CODE
OUTPUT :V2.4
=V8.3
=A 8.3 AC US US
20
OUTPUT :2.4
(A
( 1.2 1.2 A Peak
Peak 10 LAMBDA
10 sec sec max,DUTY:0.35)
max,DUTY:0.35)
46±1
DENSEI-LAMBDA
BAR BAR CODECODE
20
MADE IN JAPAN
LAMBDA
LAMBDA 2−SEE NOTE B 2−SEE NOTE B
46±1
4.5
DENSEI-LAMBDA
DENSEI-LAMBDA
MADE
MADE IN JAPAN
IN JAPAN
2−SEE
2−SEE NOTE
NOTE B B (205.3) 2−SEE
2−SEE SEE NOTE E
NOTE
NOTE B B
4.5
4−NOTE A
(205.3)
(205.3) SEESEE NOTENOTE
E E
4−NOTE
4−NOTE A A
TERMINAL
2−NOTE B
2-SEE NOTE SEEBNOTE D VOLTAGE ADJUSTMENT
2-SEE NOTE B TERMINAL
CN1 2-SEE NOTE B
CN52 COVER
COVER 2−NOTE B B
2−NOTE SEE NOTE
SEE D D
NOTE VOLTAGE 2-SEE
VOLTAGE NOTE
ADJUSTMENT
ADJUSTMENT B TERMINAL
TERMINAL
CN52 SEE NOTE E
TERMINAL
TERMINAL VR51 12
(205.3) SEE NOTE E CN52+R−R COVERCOVER
10 108.6 8.6
COVER
COVER CN1 FG
CN1
VR51 1 2 1 24-NOTE ASEE NOTE
SEE NOTE B
E
CN51
VR51
2-NOTE B (205.3)
SEESEE
NOTE E E CN2
NOTE
2 −R +R−R +R−R
OUTPUT
8.6
4-NOTE A
N
FG FG
60±0.5
40±0.5
8.6 8.6
90±190±1
INPUT OUTPUTOUTPUT
2-NOTE B SEE NOTE D VOLTAGE ADJUSTMENT 2 −R2 −R TERMINAL
10 10
L
N N
60±0.5
40±0.5
(46) 8.6
60±0.5
40±0.5
COMPONENT
COMPONENTSIDE
SIDE 1 +R1 +R −V −V
+V
90±1
INPUT
INPUT
COVER TERMINAL
(66)
VOLTAGE ADJUSTMENT
10
SEE NOTE D
4.5 4.5
L L 3−M4
TERMINAL
10
TL TL
+V +V
(53)
4.5
8.6
SEE NOTE E
(53)
2−M4
2−M4
(46)
OUTPUT
(46)
8.6
COVER
40±0.5
60±0.5
COMPONENT SIDE
8.6
45
45
90±1
INPUT OUTPUT
10
25 25
25 15
40±0.5
60±0.5
COMPONENT SIDE
8.6
10
90±1
(66)
INPUT
10
3-M4
15
4.5
15
NAME PLATE
(53)
10
5 220±0.5
(66)
(46)
33(MAX) 3-M4
4.5
220±0.5
33( MAX)
33( MAX) 230±1 2-M4
(unit : mm)
230±1
45
45
25
15
NOTES
25
15
A: M4 33(MAX)
EMBOSSED TAPPED & COUNTERSUNK 220±0.5MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN 6mm.
5 HOLES (6) ARE FOR CUSTOMER CHASSIS
B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (3) ARE FOR
33(MAX) 230±1 220±0.5
5 CUSTOMER CHASSIS MOUNTING. (USE M4 MOUNTING SCREW.)
C: MODEL NAME, NOMINAL INPUT VOLTAGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT 230±1 NAMEPEAK
CURRENT, PLATE
OUTPUT CURRENT AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN
(unit:mm)
ACCORDANCE WITH THE SPECIFICATIONS. NAME
SEE NOTE C PLATE MODEL NAME ZWS150PAF/TL
D: FG IS FOR SAFETY GROUND CONNECTION. (unit(unit
:mm)
E: REMOTE ON/OFF CONTROL CONNECTOR (CN2, CN52) : B2B-XH-AM (J.S.T.) SEE NOTE C ZWS150PAF/TL
:mm)
MODELDENSEI-LAMBDA
NAME
MODEL NAME ZWS150PAF/TL
*CN2 IS NORMALLY SHORTED BY JM-2W-96 (J.S.T.) CA723ー02ー01/TLーA
DENSEI-LAMBDA
DENSEI-LAMBDA
MATCHING HOUSING : XHP-2 (J.S.T.) CA723ー02ー01/TLーA
CA723ー02ー01/TLーA
MATCHING TERMINAL : BXH-001T-P0.6 (J.S.T.) OR SXH-001T-P0.6 (J.S.T.)
HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
【ZWS150PAF(/TA
5
】
: Vertical terminal, with cover)
220±0.5
2-SEE NOTE A
5 220±0.5
4.5
2-SEE NOTE A
7.5
4.5
7.5
20
27.5
51±1
20
46
4.5
27.5
51±1
46
4.5
TA TA
SEE NOTE B
COVER
8.6
8.6
60±0.5
入力
90±1
OUTPUT
10
INPUT
40±0.5
8.6
60±0.5
入力
90±1
10
(66)
INPUT
4.5
(66)10
(53)
3-M4
(46)
2-M4
4.5
10
(53)
3-M4
(46)
2-M4
45
45
25
15
25
15
5 220±0.5
33(MAX) 5
33(MAX) NAME PLATE
230±1 220±0.5
230±1
(unit : mm)
NAME
SEE NOTE C PLATE
NOTES SEE NOTE C ZWS
A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHASSIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE THAN 6mm.
B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (3) ARE FOR CUSTOMER CHASSIS MOUNTING. (USE M4 MOUNTING SCREW.)
-PAF
C: MODEL NAME, NOMINAL INPUT VOLTAGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM OUTPUT CURRENT, PEAK OUTPUT CURRENT AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN
ACCORDANCE WITH THE SPECIFICATIONS.
D: FG IS FOR SAFETY GROUND CONNECTION.
COMPONENT VOLTAGE
8.6
3-M4 3-M4 B: MODEL NAME, INPUT VOLTAGE RANGE,
80±1
S
VOLTAGE
10
SIDE ADJUSTMENT 2-M4 2-M4 NOMINAL OUTPUT VOLTAGE, MAXIMUM
(61)
ADJUSTMENT OUTPUT CURRENT ARE SHOWN HERE IN
(48)
(41)
ACCORDANCE WITH THE SPECIFICATIONS.
10 8.6
4-NOTE A TERMINAL
70±0.5
8.6
70±0.5
80±1
COMPONENT COVER
SS
8.6
80±1
SHOWN HERE.
10
SIDE SIDE
(61)
10
(61)
D: TO KEEP THE DISTANCE MORE THAN 4m/m
5
(8.1)
(48)
(41)
BETWEEN PC-BOARD EDGE AND CUSTOM-
(48)
5 SEE NOTE D
(41)
20 4-NOTE A (194.3) 20 TERMINAL
14.6 4-NOTE A TERMINAL
ER'S CHASSIS.
(MAX) 208±1 (MAX) COVER E: FG IS FOR SAFETY GROUND CONNECTION.
COVER
37±1 NAME PLATE F: REMOTE ON/OFF CONTROL CONNECTOR
5
(unit : mm)
NOTES:
46±1
220±0.5
220±0.5 A: M4 EMBOSSED TAPPED & COUNTERSUNK
HOLES (6) ARE FOR CUSTOMER CHASSIS
2-SEE NOTE A MOUNTING. SCREW MUST NOT PROTRUDE
20
SL
ARE SHOWN HERE IN ACCORDANCE WITH
SEE NOTE D TERMINAL
(205.3)
(205.3) SEE NOTE DCOVER
THE SPECIFICATIONS.
SEE NOTE D
10 8.6 10 8.6
8.6
TERMINAL
(66)
SEE NOTE D
SEE NOTE D TERMINAL*CN2 IS NORMALLY SHORTED BY JM-2W-
(53)
2-M4 COVER
96 (J.S.T.)
COVER
(46)
8.6
8.6
COMPONENT
10
90±1
10
10
(66)
15
(53)
2-M4 2-M4
(46)
(17.1)
5 220±0.5
23.6 (MAX)
9 230±1 (MAX)
9
NAME PLATE
15
15
51±1
46
THE SPECIFICATIONS.
4-SEE NOTE A
46
(205.3) VOLTAGE2-SEE
ADJUSTMENT
NOTENOTE
A C: FG IS FOR SAFETY GROUND CONNECTION.
SEE NOTE C 2-SEE A
TERMINAL
3-M4
SA
COVER
4-SEE NOTENOTE
A TERMINAL
4-SEE A (205.3) VOLTAGE ADJUSTMENT
SEE NOTE C (205.3) VOLTAGE ADJUSTMENT
COVER
SEE NOTE C
8.6
TERMINAL
3-M4 3-M4 TERMINAL
60±0.5
8.6
SASA
90±1
COVER
10
10
COVER TERMINAL
TERMINAL
(66)
COVER
(53)
COVER
8.6
(66) (46)
8.6
2-M4
60±0.5
8.6
60±0.5
8.6
90±1
10
10
90±1
10
10
(66)
15
(53)
(53)
(46)
(46)
15
ZWS
-PAF
Component side
Component side
Input connector
CN1
Output connector Input connector
CN51 CN1
MOUNTING(A) MOUNTING MOUNTING MOUNTING MOUNTING (F)DON'T USE (G)DON'T USE (H)DON'T USE ( I )DON'T USE
STANDARD MOUNTING (B) (C) (D) (E)
60 60 60 60
(%) (%)
(%) (%)
80 80 80 80
mounting (C),mounting
(D), (E) (C), (D), (E) 75 75
(150W) (150W)
LOADLOAD
LOADLOAD
LOADLOAD
LOADLOAD
40
60 40
60 40
60 40
60
20
40 20
40 20
40 20
40
Air velocity Air velocity
1.5m/s 1.5m/s
0
20 0
20 0
20 0
20
-10 0 10-10 200 3010 4020 5030 6040 50 60 -10 Air0 velocity
-10
10 20 Air velocity
0 3010 4020 5030 6040 7050 60 70
Ta (℃) Ta (℃) 1.5m/s Ta (℃) 1.5m/s Ta (℃)
0 0 0 0
-10 0 10-10 200 3010 4020 5030 6040 50 60 -10 0 10-10 200 3010 4020 5030 6040 7050 60 70
Ta (℃) Ta (℃) Ta (℃) Ta (℃)
60 60
(%) (%)
60 60
(%) (%)
80 80 80 80
75 75
mounting (B),mounting (150W) (150W)
LOADLOAD
LOADLOAD
40
60 40
60 40
60 40
60
mounting (B),mounting
(D) (B), (D)
20
40 20
40 20
40 20
40
Air velocity Air velocity
1.5m/s 1.5m/s
0
20 0
20 0
20 0
20
-10 0 10-10 200 3010 4020 5030 6040 50 60 10-10 20
-10 Air0 velocity 0 10 4020 5030 6040 7050 60 70
Air velocity
30
Ta (℃) Ta (℃) 1.5m/sTa (℃) 1.5m/sTa (℃)
0 0 0 0
-10 0 10-10 200 3010 4020 5030 6040 50 60 -10 Recommended
0 10-10 200 Minimum
3010 4020Air50Velocity : 0.7m/s
30 6040 70 50 60 (Measured
70 at component
Ta (℃) Ta (℃) side of PCB,Ta Air(℃) Ta through
must flow (℃) component side.)
As a reference for forced air cooling, let air flow so that the transformer
T1 core temperature is lower than 85℃.
Test point
(CORE)
ZWS
-PAF
PCB
(*1) Operating period at peak output current is less than 10 sec. (Duty < (*6) 85-265VAC, constant load.
0.35)
(*7) No load - full load (maximum power), constant input voltage.
(Average output power and current is less than maximum output
power and current.) (*8) Constant current limit with automatic recovery. Avoid to operate at
For peak load derating method, please refer to instruction manual overload or dead short for more than 30 seconds.
for details. (*9) OVP circuit will shutdown output, manual reset. (line recycle)
(*2) At 100/200VAC and maximum output power, Ta=25℃. (*10) Measured by each measuring method of UL, CSA, EN and DENAN
(*3) For cases where conformance to various safety specs (UL, CSA, (at 60Hz).
EN) are required, to be described as 100-240VAC, 50/60Hz on (*11) At standard mounting method, Fig B.
name plate. - Load(%) is percent of maximum output load (Item 2 and 5), do not
(*4) Not applicable for the in-rush current to noise filter for less than exceed derating in both maximum output current and power.
0.2ms. - For other mountings, refer to derating curve.
- When forced air cooling, refer to derating curve.
(*5) Please refer to Fig A for measurement of line & load regulation and
output ripple voltage. (*12) 85 - 265VAC, No load - full load, constant load.
(Measure with JEITA RC-9131 probe.)
RSEL-2006W
ZWS Please refer to "TDK-Lambda
-PAF EMC Filters" catalog.
(*1) Forced air cooling with air velocity more than 1.5m/s (measured at component side of PCB, ●Recommended EMC Filter
air must flow through component side).
(*2) Operating period at peak output current is less than 10 sec. (Duty ≦ 0.35)
(Average output power and current is less than maximum output power and current.)
For peak load derating method, please refer to instruction manual for details.
(*3) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as
100 - 240VAC, 50/60Hz on name plate.
(*4) At 100/200VAC and maximum output power, Ta = 25℃.
(*5) At standard mounting method A,and other mountings B, C, D, E. RSEL-2006W
- Load(%) is percent of maximum output load, do not exceed derating in both maximum output Please refer to "TDK-Lambda
current and power. EMC Filters" catalog.
(*6) Output derating for cold start up at Ta = - 10℃ for input voltage : 85VAC 80%, 90VAC 86.7%, 100-265VAC 100%.
No output derating for input voltage is required after start up for one second.
(*7) 85 - 265 VAC, full load.
ZWS
-PAF
5
95±1
(82.4)
6
J
7
8
* NOT INCLUDED WITH THE PRODUCT.
(62.5)
(58.7)
SOCKET HOUSING (CN1) VHR-5N J.S.T. 1
SOCKET HOUSING (CN51) VHR-8N J.S.T. 1
TERMINAL PINS (CN1, CN51) SVH-21T-P1.1 J.S.T. 11
5
42±1 5 132±0.5
SEE NOTE F NAME PLATE SEE NOTE D
VOLTAGE
LEAD CUT (207) SEE NOTES B&C
ADJUSTMENT (unit : mm) HAND CRIMPING TOOL : YC-160R MANUFACTURER : J.S.T.
LESS THAN 3mm 212±0.5 222±1 5-NOTE A
SEE NOTE F
SEE NOTE E
NOTES: E. FG IS FOR SAFETY GROUND CONNECTION.
A. THE 5-φ3.5 HOLES ARE CUSTOMER'S
5 CHASSIS MOUNTING HOLES. ALL MUST BE 2 F. REMOTE ON/OFF CONTROL CONNECTOR (CN2,CN52) : B2B-XH-AM (J.S.T.)
1
3
COMPONENT
SPEC.SIDE
3
SCREWED IN ORDER TO CONFORM
INPUT
THE VIBRATION 4 *CN2
OUTPUT IS NORMALLY SHORTED BY JM-2W-96(J.S.T.)
85±0.5
5
95±1
(82.4)
B. MODEL NAME, INPUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM 6
MATCHING HOUSING : XHP-2 (J.S.T.)
J
7
8
OUTPUT CURRENT ARE SHOWN 5 HERE IN ACCORDANCE WITH THE SPECIFICA-
235±0.5 MATCHING TERMINAL : BXH-001T-P0.6 (J.S.T.) OR SXH-001T-P0.6 (J.S.T.)
(62.5)
(58.7)
TIONS. HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
2-SEE NOTE A
35±0.5 10
D. TO
LEAD CUTKEEP THE DISTANCE MORE THAN 4m/m BETWEEN PC-BOARD EDGE AND
ADJUSTMENT
51±1
LESS CUSTOMER'S
THAN 3mm CHASSIS. 212±0.5 5-NOTE A
SEE NOTE F
4.5
42±1 5 132±0.5 NAME PLATE SEE NOTE D
SEE NOTE E (207) SEE NOTES B&C
2-SEE NOTE B 222±1 SEE NOTE B
SEE 2NOTE E
5 1
J JL
5
95±1
1
(82.4)
6
4-SEE NOTE A
SEE NOTE D
7
8
VR51
(62.5)
(58.7)
5 VOLTAGE 1
2 SEE NOTE B
3
COMPONENT SIDE ADJUSTMENT 3
4
5 1 235±0.5 5
CONNECTORS USED
45±0.5
1735±0.5 65±0.5
30105±1
6
7
8
105
2-SEE NOTE A
(87.4)
NAME PLATE SEE NOTE D PART DESCRIPTION PART NAME MANUFACTURER QTY
4.5
42±1 5 132±0.5
SEE NOTES B&C
(67.5)
(63.7)
(207)
51±1
222±1
4.5
2-SEE NOTE B SEE NOTE B * OUTPUT CURRENT OF EACH CONNECTOR PIN MUST BE LESS THAN 5A.
5 235±0.5
(218.5)245±1 SEE NOTE E
2-SEE NOTE B SEE NOTE E MATCHING HOUSINGS & PIN.
NAME PLATE
5
SEE NOTE D
235±0.5
SEE NOTE C
VR51
4-SEE NOTE A
SOCKET HOUSING (CN1) VHR-5N JL
* NOT INCLUDED WITH THE PRODUCT.
J.S.T. 1
VOLTAGE 1
SEE NOTE
2-SEE NOTEBA SOCKET HOUSING (CN51) VHR-8N J.S.T. 1
35±0.5 10
5 2
3
COMPONENT SIDE ADJUSTMENT 3
65±0.5 30
4
5
TERMINAL PINS (CN1, CN51) SVH-21T-P1.1 J.S.T. 11
51±1
1
45±0.5
105±1
6
7
8
HAND CRIMPING TOOL : YC-160R MANUFACTURER : J.S.T.
4.5
(87.4)
4.5
(67.5)
(63.7)
5 235±0.5
2-SEE NOTE B
53
SEE NOTE B
SEE NOTE E
35±0.5 10
(unit : mm)
JL
4.5
VR51
245±1
5 VOLTAGE
NAME PLATE SEE NOTE B
1
2
2-SEE NOTE B 3
COMPONENT SIDE ADJUSTMENT
SEE NOTE C SEE NOTE B
3
4
5
NOTES SEE NOTE D ACCORDANCE WITH THE SPECIFICATIONS.
1
45±0.5
65±0.5
2-SEE NOTE B
105±1
(218.5) 6
JA
7
A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHAS- D: FG IS FOR SAFETY GROUND CONNECTION. 8
(87.4)
4.5
SIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE E: REMOTE 4-SEEON/OFFNOTE A
CONTROL CONNECTOR (CN2, CN52) : B2B-XH-AM (J.S.T.)
(67.5)
(63.7)
51
THAN 6mm. *CN2 IS NORMALLY SHORTED BY JM-2W-96(J.S.T.)
53
B: φ 4.5 HOLES (4) AND R2.25 SLOT HOLES (3) ARE FOR CUSTOMER CHASSIS MATCHING HOUSING : XHP-2 (J.S.T.)
VOLTAGE SEE NOTE B : BXH-001T-P0.6 (J.S.T.) OR SXH-001T-P0.6 (J.S.T.)
1
5
MOUNTING. (USE M4 MOUNTING SCREW.) MATCHING TERMINAL 2
27
30105±1 17
ADJUSTMENT
3
C: MODEL NAME, INPUT VOLTAGE5 INPUTRANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM HANDOUTPUT
4
235±0.5 CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T. 5
45±0.5
17 35±0.5 65±0.5
1
6
2-SEE NOTE A
(87.4)
245±1
4.5
(67.5)
(63.7)
NAME PLATE
56±1
SEE NOTE C
53
4.5
JA
NAME PLATE
SEE NOTE C 4-SEE NOTE A
51
5 235±0.5
CONNECTORS USED
35±0.5 10
VOLTAGE 2-SEE
SEE NOTE
NOTE B A
1
5
2
ADJUSTMENT
3
INPUT OUTPUT
4
56±1
5
45±0.5
1
105±1
8
(87.4)
(67.5)
JA
27
245±1
NAME PLATE
SOCKET HOUSING (CN1) VHR-5N J.S.T. 1
VOLTAGE SEE NOTE B
1
ADJUSTMENT
3
INPUT OUTPUT
4
5
1
105±1
6
7
8
(87.4)
(63.7)
53
27
17
5 235±0.5
245±1
(unit : mm)
NAME PLATE
ZWS SEE NOTE C
-PAF NOTES
A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHAS-
MOUNTING. (USE M4 MOUNTING SCREW.)
C: MODEL NAME, INPUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM
SIS MOUNTING, SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE OUTPUT CURRENT, AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN AC-
THAN 6mm. CORDANCE WITH THE SPECIFICATIONS.
B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (2) ARE FOR CUSTOMER CHASSIS D: FG IS FOR SAFETY GROUND CONNECTION.
10 8.6
LEAD CUT
8.6
COMPONENT SIDE VOLTAGE OUTPUT
10
LESS THAN 3mm
85±0.5
INPUT
95±1
ADJUSTMENT 5-NOTE A
(82.4)
212±0.5
TERMINAL COVER
SEE NOTE F
2-M4
SEE NOTE E
3-M4
(61.6)
(58.9)
SEE NOTE F TERMINAL COVER
T
10 8.6
NAME PLATE
8.6
COMPONENT SIDE
SEE NOTES B&C OUTPUT
10
85±0.5 INPUT
95±1
(82.4)
(unit : mm)
5
24(MAX) 5 132±0.5 SEE NOTE D
3-M4 (207) 2-M4
(61.6)
(58.9)
42±1
222±1
T
NOTES: NAME PLATE CUSTOMER'S CHASSIS.
SEE NOTES
A. THE 5-φ3.5 HOLES ARE CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE B&CE. FG IS FOR SAFETY GROUND CONNECTION.
5
2-SEE NOTE A
30
51±1
4.5
5 235±0.5
2-SEE NOTE B SEE NOTE B A
35±0.5 10
2-SEE NOTE
2-SEE NOTE B (218.5)
VOLTAGE ADJUSTMENT
30
51±1
SEE NOTE E
SEE NOTE D 4-SEE NOTE A
4.5
TERMINAL
SEE NOTE E TERMINAL COVER
TL
8.6
2-SEE NOTE B
COVER SEE
SEENOTE
NOTEBB
10 8.6
COMPONENT SIDE OUTPUT
2-SEE NOTE B (218.5)
VOLTAGE ADJUSTMENT
10
INPUT
105±1
65±0.5
45±0.5
SEE NOTE E
3-M4
(87.4)
2-M4
4.5
SEE NOTE D 4-SEE NOTE A
TL
(63.9)
(66.6)
53
8.6
COMPONENT
SEE NOTE C SIDE OUTPUT
27
10
65±0.517
INPUT
105±1
45±0.5
2-M4
4.5
245±1
(63.9)
(66.6)
53
NAME PLATE
SEE NOTE C
27
17
OUTPUT CURRENT, AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN AC- HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
【ZWS240PAF(/TA 】
4.5
2-φ4.5
: Vertical terminal, with235±0.5
cover)
(取付用穴) 5
SEE NOTE
2-SEE B A
NOTE
35±0.5 10
2-SEE NOTE B
30
(218.5)
235±0.5
ADJUSTMENT
5
4-SEE NOTE A
4.5
TA
235±0.5
TERMINAL 5 5 235±0.5
TERMINAL COVER
10 10
COVER
NAME PLATE 4 SEE NOTE A
SEE NOTE B
56 ±1 10
105±1 30 30
35±0.5
SEE NOTE C
NAME PLATE 2-SEE NOTE B
8.6
SEE NOTE C
65±0.535±0.5
ZWS240PAF- 24 /TA
8.6
SEE NOTE C
50/60Hz
56 ±1
ZWS240PAF- 24 /TA 24
10
INPUT
ADJUSTMENT
10
OUTPUT: 2.4 V = 10 A
4.5 4.5
C US
ZWS240PAF- /TA
(2.0 A Peak,10 sec max,DUTY:0.35)
INPUT: 100 - 240VAC~3.5A
45±0.5
BARUS CODE
50/60Hz INPUT: 100 - 240VAC~3.5A
4-SEE NOTE A
OUTPUT: 2.4 V = 10 A 50/60Hz
4.5
C
2.4 V = 10 A
TA
(2.0 A Peak,10OUTPUT:
sec max,DUTY:0.35)
C US
LAMBDA
(87.4)
3-M4
(2.0 A Peak,10 sec max,DUTY:0.35)
TERMINAL
BAR CODE DENSEI-LAMBDA
4.5
BAR
MADE INCODE
TERMINAL COVER
JA PAN
LAMBDA
(63.9)
COVER2-SEE NOTE
LAMBDA
(66.6)
53
2-SEE 2-SEE
NOTE NOTE
B (218.5) NOTE
2-SEE NOTE BB SEE NOTE B
VOLTAGE ADJUSTMENT
8.6
SEE NOTE D
SEE NOTE D (218.5)
(218.5) VOLTAGE
OUTPUT ADJUSTMENT
VOLTAGE ADJUSTMENT
27
INPUT
10
65±0.517
4 SEE NOTE A
105±1
45±0.5
TERMINAL VR51
4 SEE NOTE A A
3-M4 NAME PLATE 4 SEE NOTE
(87.4)
245±1
(66.6)
TERMINAL
SEE NOTE B
53
FG NFG N L
N
105±1
10 10 8
OUTPUT
INPUT SEE NOTE B B
SEE NOTE
10 10
-V +V -V
8.6
L
27
L
65±0.5
105±1
45±0.5105±1
N N
L
45±0.5
17
OUTPUTOUTPUT
10
INPUT INPUT
(63.9) 10
3 M4 +V +V
65±0.5
65±0.5
L L
45±0.5
NAME PLATE
4.5 4.5
33(MAX) 5 235±0.5
(87.4)
3 M43 M4 2 M4
245±1
4.5
(66.6)
(63.9)
(63.9)
(87.4)
(87.4)
2 M4
2 M4
53 53
(66.6)
(66.6)
53
27 27
17 17
(unit : mm)
27
17
33 (MAX) 5 235±0.5
245±1
33 (MAX)
33 (MAX) 5 5 NAMEPLATE 235±0.5
235±0.5
245±1
SEE NOTE C 245±1
NAMEPLATE
NAMEPLATE ZWS
NOTES
SEE NOTE
SEE NOTE C C
MOUNTING. (USE M4 MOUNTING SCREW.) -PAF
A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHAS- C: MODEL NAME, INPUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM
(unit:mm)
SIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE OUTPUT CURRENT, AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN AC-
MODEL NAME ZWS240PAF/TA
THAN 6mm. CORDANCE WITH THE SPECIFICATIONS. (unit:mm)
(unit:mm)
B: φ4.5 HOLES (4) AND R2.25 SLOT HOLES (2) ARE FOR CUSTOMER CHASSIS D: FG IS FOR SAFETY GROUND CONNECTION.
MODEL NAME ZWS240PAF/TA
DENSEI-LAMBDA
MODEL NAME ZWS240PAF/TA
CA724-02-01/TA-B
DENSEI-LAMBDA
DENSEI-LAMBDA
CA724-02-01/TA-B
CA724-02-01/TA-B
8.6
8.6
COMPONENT SIDE
10
85±0.5
10
95±1
(82.4)
INPUT
LEAD CUT VOLTAGE
LESS THAN 3mm SEE NOTE E ADJUSTMENT TERMINAL
(58.9)
3-M4 212±0.5 5-NOTE A
COVER
(61.6)
SEE NOTE
2-M4 F
NAME PLATE
SEE NOTE F
SEE NOTES B&C
8.6
8.6
COMPONENT SIDE
10
85±0.55
(82.4)
INPUT
5 132±0.5
TERMINAL
(58.9)
14.6 3-M4 (207)
COVER
(61.6)
42±1 20(MAX) 222±1 20(MAX)
2-M4
NOTES NAME
D. TOPLATE
KEEP THE DISTANCE MORE THAN 4m/m BETWEEN PC-BOARD EDGE AND
A. THE 5-φ3.5 HOLES ARE CUSTOMER'S CHASSIS MOUNTING HOLES. ALL MUST BE SEE CUSTOMER'S
NOTES B&CCHASSIS.
SCREWED IN ORDER TO CONFORM THE VIBRATION SPEC. E. FG IS FOR SAFETY GROUND CONNECTION.
5
B. MODEL NAME, INPUT VOLTAGE RANGE,NOMINAL OUTPUT VOLTAGE, MAXIMUM F. REMOTE ON/OFF CONTROL CONNECTOR (CN2, CN52) : B2B-XH-AM (J.S.T.)
(8.1)
OUTPUT CURRENT ARE SHOWN HERE IN ACCORDANCE WITH 5THE SPECIFICA- 132±0.5*CN2 IS NORMALLY SHORTEDSEE NOTE D
BY JM-2W-96(J.S.T.)
TIONS. MATCHING HOUSING : XHP-2 (J.S.T.)
14.6 (207)
C. COUNTRY OF MANUFACTURE WILL BE SHOWN HERE. MATCHING TERMINAL : BXH-001T-P0.6 (J.S.T.) OR SXH-001T-P0.6 (J.S.T.)
42±1 20(MAX) HAND CRIMPING 20(MAX)
222±1 TOOL : YC-110R OR YRS-110 MANUFACTURER : J.S.T.
5 235±0.5
2-SEE
5 5 235±0.5
30 51±1
5 235±0.5
30
NAME PLATE
NAME PLATE
SEE NOTE
SEECNOTE C
SEE NOTE D VOLTAGE ADJUSTMENT
NAME PLATE
ZWS150PAF- 24 /TA 24 /TA
ZWS150PAF- SEE NOTE C
(218.5) 2−SEENOTE
2−SEE NOTEA A
INPUT:100 ー240VAC
INPUT:∼3.5A
100 ー240VAC ∼3.5A SEE NOTE D
50/60Hz
OUTPUT:2.4 V =
50/60Hz
10 A :2.4 VC = 10 A US C
ZWS150PAF- 24 /TA
OUTPUT US 2−SEE NOTE A
TERMINAL 4-SEE NOTE A
51±1
3-M4
OUTPUT:2.4 V = 10 A
LAMBDA LAMBDA
COVER
C US
MADE IN CHINA
8.6
COVER
COVER
TERMINAL (218.5) SIDE SEE NOTE D
COMPONENT SEENOTE
SEE NOTED D
10
COVER +R +R −R −RSEE NOTE D VOLTAGE ADJUSTMENT
NOTE
SEESEE NOTE
C C 4−SEE
4−SEE NOTE D AA
10
NOTE
10
SEE NOTE
105±1
65±0.5
12 12
(218.5) VR51CN52
VR51
(87.4)
+RCN2−R
CN2
CN52 2-M4 NOTE A
4−SEE
CN1 CN1 SEE NOTE C SEE NOTE D
TERMINAL
TERMINAL
21
−R+R
−R+R
21
12
VR51
VOLYAGE CN51
CN2 VOLYAGE CN52
(63.9)
10 108.6 8.6
CN51 COVER
8.6
TERMINAL FG CN1
4-SEECOVER
NOTE A
FG
TERMINAL
−R+R
21
ADJUSTMENT
ADJUSTMENT
COMPONENT SIDE
(66.6)
105±1
INPUT
105±1 105±1
INPUT 8.6
(87.4)
−V
(87.4)
N +V +V
L L OUTPUT
10 8.6
105±1
INPUT
(87.4)
+V
(66.6)
(63.9)
(66.6)
(63.9)
65±0.5 17
3−M4 L 2−M4
3−M4 COMPONENT SIDE 2−M4 65±0.510
(66.6)
(63.9)
3−M4 2−M4
10
17.1 5 235±0.5
(87.4)
2-M4
65±0.5
NAME
NOTEPLATE NAME PLATE
17 17
17
245±1 8.5
23.6
NOTES 17.1 5 C: FG IS FOR 235±0.5
SAFETY GROUND CONNECTION.
A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES8.5(MAX)
(6) ARE FOR CUSTOMER CHAS- D: REMOTE ON/OFF
245±1CONTROL CONNECTOR (CN2.CN52) : B2B-XH-AM 8.5(MAX)(J.S.T.)
23.6
SIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE *CN2 IS NORMALLY SHORTED BY JM-2W-96(J.S.T.)
THAN 6mm. 5 235±0.5
MATCHING HOUSING : XHP-2 (J.S.T.)
B: MODEL NAME, INPUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM MATCHING TERMINAL : BXH-001T-P0.6 (J.S.T.) OR SXH-001T-P0.6 (J.S.T.)
(unit:mm)
OUTPUT CURRENT, AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN AC- HAND CRIMPING TOOL : YC-110R OR YRS-110 MANUFACTURER :mm)
(unit: J.S.T.
CORDANCE WITH THE SPECIFICATIONS. MODEL NAME ZWS240PAF/SL
(unit:mm)
30
DENSEI-LAMBDA
MODEL NAME ZWS240PAF/SL
8.6
10
10
VOLTAGE ADJUSTMENT
10
105±1
3-M4
65±0.5
COVER
8.6
8.6
8.6
1017
10
10
5 235±0.5 2-M4
(87.4)
17
-PAF NOTES B: MODEL NAME, INPUT VOLTAGE RANGE, NOMINAL OUTPUT VOLTAGE, MAXIMUM
A: M4 EMBOSSED TAPPED & COUNTERSUNK HOLES (6) ARE FOR CUSTOMER CHAS- OUTPUT CURRENT, AND COUNTRY OF MANUFACTURE ARE SHOWN HERE IN AC-
SIS MOUNTING. SCREW MUST NOT PROTRUDE INTO POWER SUPPLY BY MORE CORDANCE WITH THE SPECIFICATIONS.
THAN 6mm. C: FG IS FOR SAFETY GROUND CONNECTION.
Component side
Input connector
CN1
Output connector Input connector
CN51 CN1
MOUNTING(A) MOUNTING MOUNTING MOUNTING MOUNTING (F)DON'T USE
(STANDARD MOUNTING) (B) (C) (D) (E)
Component side
Input connector
CN1
Output connector Input connector
120 120 CN51 CN1 120 120
MOUNTING(A) MOUNTING MOUNTING MOUNTING MOUNTING (F) DON'T USEMOUNTING
MOUNTING (G)
(A), (B), DON'T
(C),
(A),
(D), USE
(E)(C), (H)
(B), DON'T USE ( I )
(D), (E) DON'T USE
(STANDARD MOUNTING) (B) MOUNTING
(C)MOUNTING
(A) (D) (A) (E)
100
*COOLING:
100
(240W) CONVECTION
(240W) COOLINGMOUNTING (B)MOUNTING (B) (300W)*COOLING:
100 100
(300W) FORCED AIR COOLING
OUTPUT
80 DERATING
80 CURVE(PCB type and with chassis) 80
OUTPUT
80
DERATING CURVE(PCB type and with chassis)
120 120 120 120
LOAD (%)
LOAD (%)
LOAD (%)
LOAD (%)
MOUNTING
MOUNTING
(A), (B), (C),(A),
(D), (E)(C), (D), (E)
(B),
60
60 MOUNTING MOUNTING
(A) (A) 60 60
100
100 100 100
MOUNTING
(240W) (240W) MOUNTING MOUNTING
(C), (D) (C), (D) (B)MOUNTING (B) (300W) (300W)
40 40 40 40
80 80 MOUNTING MOUNTING
(E) (E) 80 80
LOAD (%)
LOAD (%)
LOAD (%)
LOAD (%)
20 20 20 Air velocity
20 Air velocity
60 60 60 1.5m/s 1.5m/s
60
0.7m/s 0.7m/s
0 MOUNTING
0 MOUNTING
(C), (D) (C), (D) 0 0
40-10 0 40-10
10 020 10
30 20 40 3050 4060 50
70 60 70 40-10 0 40-10 10 020 10
30 20
40 30
50 40
60 50
70 60 70
MOUNTING
Ta (℃) MOUNTING
Ta (℃) (E)
(E) Ta (℃) Ta (℃)
20 20 20 Air velocity
20 Air velocity
1.5m/s 1.5m/s
0.7m/s 0.7m/s
0 0 0 0
-10 0 10
-10 20
0 30
10 40
20 50
30 60
40 70
50 60 70 -10 0 -10 10 20
0 30 20
10 40 50
30 60
40 70
50 60 70
Ta (℃) Ta (℃) Ta (℃) Ta (℃)
80 80 80 80
120 120 120 120
LOAD (%)
LOAD (%)
LOAD(%)
LOAD(%)
MOUNTING
MOUNTING
(A), (B), (C),(A),
(D), (E)(C), (D), (E)
(B),
60 60 MOUNTING MOUNTING
(A) (A) 60 60
100 MOUNTING
100 MOUNTING
(B), (C) (B), (C) 100 100
(240W) (240W) (300W) (300W)
40 40 40 40
80 80 80 80
MOUNTING
MOUNTING
(D), (E) (D), (E)
LOAD (%)
LOAD (%)
LOAD(%)
LOAD(%)
20 20 20 Air velocity
20 Air velocity
60 60 60 1.5m/s 1.5m/s
60
MOUNTING MOUNTING
(B), (C) (B), (C) 0.7m/s 0.7m/s
0 0 0 0
40-10 0 40-10
10 020 10 30 2040 30 50 40
60 50
70 60 70 40-10 0 40-1010 020 1030 20
40 30
50 40
60 50
70 60 70
MOUNTINGTa
(D),(℃)
(E) Ta
MOUNTING (D),(℃)
(E) Ta (℃) Ta (℃)
20 20 20 Air velocity
Recommended20 Air velocityAir Velocity:0.7m/s (Measured at component side of PCB,
Minimum
1.5m/s 1.5m/s
Air must flow through
0.7m/s 0.7m/s component side.)
0 0 0 As a reference
0 for forced air cooling, let air flow so that the transformer T1 core
-10 0 10
-10 20
0 30
10 40
20 50
30 60
40 70
50 60 70 -10 0 -10 10 200 30 20
10 40 30
50 40 60 5070 60 70
temperature is lower than 85℃ .
Ta (℃) Ta (℃) Ta (℃) Ta (℃)
Test Point
(CORE)
ZWS
-PAF
PCB
【ZWS150PAF, ZWS240PAF】
Switching Circuit
Rectifier
Output
Filter
OCP
Circuit
Control Circuit
Photo- Output
Coupler Sensing
Remote Photo-
Control Coupler
ZWS
-PAF
1 ZWS150PAF MTW
● Input & Output connector (MOLEX)
CN52
(also for option model /L, /A) RKE
CN1 VR51
RKY
4 N −R 5
6 L CN2
+R 4
3
5239-06
2
1 Input (CN1) 5414-30B or 2139-06 5167PBTL
+
or 3069-06
5239-06
RTW
Output (CN51) 5273-06A or 2139-06 5167PBTL
① L: AC Input terminal (pin 6 of CN1)
or 3069-06
Live line (fuse in line) SWT
*Output current of each connector pin must be less than 5A.
② N: AC input terminal (pin 4 of CN1)
*Hand crimping tooling: JHTR2445A (MOLEX)
Neutral line
③ FG: Input terminal FG (pin 1 of CN1) ● Connector for Remote ON/OFF
CN52
UNA
Safety earth (Frame Ground) control: CN2, CN52 (J.S.T)
VR51
CN1
+R −R
5 FG
CN51−
BXH-001T-P0.6
equipment by electrically conductive spacers. The mounting B2B-XH-AM XHP-2
surface of the spacer should be within MAX 8mm.
or SXH-001T-P0.6 VS-P
⑤ CN2: ON/OFF control terminal (primary circuit) See NOTE A. *CN2 is normally shorted by JM-2W-96 (J.S.T)
⑥ +: + Output terminal *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T)
ZUP
⑦ −: − Output terminal
⑧ V.ADJ: Output voltage adjust trimmer (VR51) The output voltage rises
CN52
CN1 VR51
6
N
L
+R −R
−R
+R
5
4
signal.) ZWQ
+R
CN2 +
L
See NOTE A. +
NOTE A: For cover & chassis type (model: ZWS150PAF/A), remote ON/OFF control cannot be used.
ZWS
2 ZWS150PAF/J
CN52
VR51
CN1
+R −R
5 FG CN52
CN1
CN51−
VR51
3 N 1
ZWS
FG +R −R 2
1 L CN51 − 3
−R 4
N
CN2
−R
+R CN2
+R 5
6 -PAF
L +
HK-A CN2 6
+
HWS
3 ZWS150PAF/T
JWS-P CN52
CN1 VR51
1 FG +R −R
CN51−
JWT 4 CN1 N
6 L FG
−R
+R
6CN52
VR515
4
CN2 3+R −R
CN51
2 −
1
N −R +
+R
MTW L
CN2
RKE
RKY ① L: AC Input terminal L (M4 screw) ● Input & output connector (EMUDEN)
Live line (fuse in line)
② N: AC input terminal N (M4 screw)
(also for option model /TL, /TA)
CN52
(For power supply output onN and off control with an external sig- −R *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T)
ZUP nal.) L
CN2
+R
See NOTE A.
NOTE A: For cover & chassis type (model: ZWS150PAF/TA), remote ON/OFF control cannot be used.
+
ZWD-
PAF
ZWQ
4 ZWS150PAF/S
ZWS
CN52
CN1 VR51
FG +R −R
CN51 −
N −R
+R
CN2
L
ZWS
-PAF
Pay attention to the input wiring. If it is connected to wrong ter- ● Remote ON/OFF control lines shall be twisted or use shield- JWS-P
minal, the power supply will be damaged. ed wire.
● Input must be off when making connections. ● Use the input/output connector housing, terminal pin as
● Connect FG terminal of input connector and mountable FG to
FG specified in outline drawing. Also, use recommended crimp-
VR51
CN52 JWT
ground terminal of the equipment. ing tool. Connector housing and terminal pin are not included
CN1
1 +R −R
EARTH COMPONENT SIDE
● Output current of each connector pin must be less than 5A. with this product.
CN51
6
MTW
4 N −R − 5
INPUT
(Except /T, /S models in which M4 screw is used.) ● When connecting or removing connector, do not apply stress
+R
LOAD
4
6 L OUTPUT CN2 3
85VAC - + 2
1
twisted to improve noise sensitivity.
+R −R
EARTH COMPONENT SIDE
FG4 N −R
CN51
6
− 5CN52
RKE
INPUT +R
LOAD
CN1 VR514
6 L CN2 OUTPUT 3
85VAC - 1 +R −R
EARTH COMPONENT SIDE + 2
ZWS150PAF 265VAC
4 N −R
CN51
1
−
6
5 RKY
INPUT +R
LOAD
FG 6 CN52
4
L CN2 OUTPUT VR51 3
85VAC - CN1
+ 2
265VAC
EARTH
1
COMPONENT SIDE
+R
1 −R
CN51
RTW
6
4 N −R − 5
INPUT +R
LOAD
4
6 L CN2 OUTPUT 3
85VAC - + 2
265VAC CN52
1
FG
VR51
CN1
EARTH
5
COMPONENT SIDE CN51
1
+R −R
SWT
3 N
INPUT − 2
LOAD
3
85VAC -
1 L
−R OUTPUT 4
+R + 5CN52
265VAC
FG
CN1
CN2
VR51
6
+R −R
UNA
ZWS150PAF/J COMPONENT SIDE
5
EARTH CN51
3 N 1
− 2CN52
FG INPUT
LOAD
3
1 L
OUTPUT
VS
VR51
85VAC - CN1 −R 4
+R −R
+R + 5
265VAC
EARTH
5
COMPONENT SIDE CN2 CN51
6
3 N 1
INPUT − 2
LOAD
3CN52
85VAC - FG
1 L
−R OUTPUT 4
VR51 + 5
VS-P
+R
265VAC CN1
CN2 6+R −R
EARTH
5
COMPONENT SIDE CN51
3 N 1
INPUT − 2
LOAD
3
85VAC -
1 L
−R OUTPUT 4
+R 5
265VAC + CN52
CN1
FG
COMPONENT SIDE
CN2 VR51 6
+R −R
ZUP
EARTH CN51
N −R
ZWS150PAF/T
−
INPUT
ZWD-
LOAD
+R
CN2 OUTPUT
PAF
L
85VAC - +
CN52
265VAC CN1 VR51
FG
COMPONENT SIDE +R −R
EARTH CN51
CN1
N
INPUT
−R −
VR51
CN52
ZWQ
LOAD
+R
LFG
COMPONENT SIDECN2 OUTPUT
+R −R
85VAC
EARTH- +
CN51
265VAC
N −R −
INPUT
ZWS
LOAD
+R CN52
CN1 CN2 OUTPUT VR51
85VAC -
L
FG
COMPONENT SIDE +
+R −R
265VAC
EARTH CN51
N −R −
INPUT
LOAD
+R
CN2 OUTPUT
L
85VAC - +
265VAC
ZWS150PAF/S CN52
CN1 VR51
FG
COMPONENT SIDE +R −R
EARTH CN51
N −R −
INPUT
LOAD
+R
85VAC -
L
CN2 OUTPUT
+ CN52 ZWS
265VAC CN1
FG
COMPONENT SIDE
VR51
+R −R
-PAF
EARTH CN51
N −R CN52
CN1 −
VR51
INPUT
LOAD
+R
+R CN52
A-463
CN1 CN2 OUTPUT VR51
・All specifications are subject to85VAC
change
- without notice.
L
FG
COMPONENT SIDE +
+R −R
265VAC
EARTH CN51
N −R −
D
+R
ZWS150PAF SERIES
are required, input voltage range will be 100 - 240VAC Film Capacitor
Elecctroly Capacitor
DLP (50/60Hz).
Film Capacitor
FPS
2 Output Voltage Range 8 Series Operation
Genesys V.ADJ trimmer (VR51) that is nearby to output connector is For series operation, either method (A) or (B) is possible.
for output voltage adjustment within the range of specifica- Power Power
tions. To turn the trimmer clockwise, the output voltage will Supply Supply
HK-A
be increased. Note over voltage protection (OVP) function Output Output
Load
Terminal Terminal
may trigger if the output voltage is increased excessively.
HWS Load
Output Output
3 Inrush Current
Load
Terminal Terminal
JWS-P
This series uses power thermistor to protect the circuit Method(A) Method(B)
JWT from inrush current. Please carefully select input switch
and fuse in cases of the high temperature and the power
re-input.
9 Parallel Operation
MTW
(A)To increase the output current is not possible.
Load
ZWD-
PAF
6 Over Temperature Protection (OTP) Output
Terminal
(B)
For /OTP, /JOTP, /TOTP, /SOTP models, OTP circuit is
ZWQ built into the power supply to prevent power supply from
damage when ambient temperature over the specification.
Peak Output Current
ZWS For ZWS150PAF series, the peak output current should
7 Output Ripple & Noise satisfy the conditions below:
1) Should not exceed the rated peak current in the speci-
The standard specification for maximum ripple value is fications. (eg. 12A for ZWS150PAF-24)
measured according to measurement circuit specified 2) D uty cycle of the peak output current should be <
by JEITA-RC9131. When load lines are longer, ripple 35%, and operating time of peak output current is less
ZWS becomes larger. In this case, electrolytic capacitor, film than 10 seconds. If the power supply is operated under
-PAF capacitor, etc. might be necessary to use across the load convection cooling, and ambient exceeds 50℃, the
terminal. The output ripple cannot be measured accurately following operating period for peak current is recom-
if the probe ground lead of oscilloscope is too long. mended.
Using CN2
3) The relation between peak output current with maxi-
It is controlled by short or open between +R & -R of CN2.
mum average output current is defined as below:
CN2 is provided in the primary circuit for ON/OFF control
by means of a switch or other device. When using this con- Alpha II
nector, which is considered to be electrically connected to
the mains input voltage, all the requirements of EN60950 DLP
must be met with respect to the connector, wiring and
switch etc.
FPS
Ip=Peak output current
Im=Minimum output current In particular:
D=Duty cycle, τ/T 1) Basic insulation must be provided between the ON/ Genesys
τ=Peak output current operating time OFF control circuit and earth.
T=Period 2) Reinforced insulation must be provided between the HK-A
Io=Maximum allowable average output current ON/OFF control circuit and any secondary circuit or
speifications (Io should be average load after accessible part. HWS
derating at various mounting and ambient 3) Wiring must be routed such that damage to the insula-
temperature) tion of the wire or additional sleeving cannot occur.
JWS-P
4) The switch must meet requirements for reinforced insu-
Formula:
lation from the ON/OFF control circuit to actuator/ac-
ZWS150PAF: 1.4×Io2>Ip2×D+Im2×(1-D) JWT
cessible parts.
Isolation Test
Remote ON/OFF Control Isolation resistance between output and FG (Chassis) shall
Remote ON/OFF control (CN2, CN52) function is avail- be more than 100MΩ at 500VDC. For safety operation,
ZWS
-PAF
able. Using this function allows the user to turn the output voltage setting of DC isolation tester must be done before
on and off without having to turn the AC input on and off. the test. Ensure that it is fully discharged after the test.
Alpha II
Withstand Voltage 2kVAC 1min. (20mA) 500VAC 1min. (100mA)
(%) Load(%)
trapped inside the unit. Refer to the derating below. In the 80
120
80
120 Mounting (A), (B), (C
Mounting (A), (B)
MTW following derating curve, average load (%) is percent of 60 60
100 100
maximum output load (both maximum output current and
Average
Average
(150W)
40 Mounting (C), (D), (E) 40
maximum output power in specifications). Do not exceed 80 80
RKE Mounting (A), (B), (C
Average Load
Average Load
Mounting (A), (B)
the load deratings. 20
60
20
60
0 0
RKY 10 Mounting
20 30(C),40
(D), (E)
● PCB type
40-10 0 50 60 70 40-10 0 10 20 30 40
Input
Input
InputInput
Output
Output
Output
Output Ambient Temperature
(℃) Ambient Tempera
Input
Input
InputInput 20 20
Convection Average Load(%)
RTW Component
Component
Component
Component Ta 0
Mounting
A B C D E
0
−10 0
-10 to 40℃ 10 100
20 30
100 40100 50 100
60 100
70 -10 0 10 20 30 4
50℃Ambient 100Temperature
100 80 (℃) 80 80 Ambient Tempera
Input
Input
InputInput
SWT Output
Output
Output Input
Output Input
InputInput
120 55℃
60℃
85
70
85
70
70
60
70
60
70
60
120
Mounting (A)
(A) (B) (C) (D) (E) (F)Prohibit 100 100
(150W)
With chassis and cover type
(%)
(%)
UNA Standard Mounting
80 80
120 Mounting (C), (E) 120 Mounting (A), (B), (C), (D
(%) Load
(%) Load
Mounting (A)
● With chassis, with chassis&cover type
60 60
VS 100 100
Average
Average
Output
(150W) Mounting (B), (D)
Input
Input 40 40
80 80
Mounting (C), (E) Mounting (A), (B), (C), (D
Average Load
Average Load
Component
VS-P 20
60
20
60
ZWQ Convection
Mounting
Average Load(%)
A B C D E
Ta
−10 to 15℃ 100 100 100 100 100
ZWS 20℃
30℃
100
100
100
80
95
80
100
80
95
80
40℃ 80 65 65 65 65
ut Input 50℃ 65 50 56 50 56
(F)Prohibit (G)Prohibit (H)Prohibit ( I )Prohibit
ZWS
-PAF
C6 T1
100
120
Average Load(%)
80 PCB
100
Mounting (A), (B), (C), (D), (E)
unting (A), (B) Average Load(%)
60
80 NON CONDUCTIVE, ISOLATED SPACER
Mounting (A), (B), (C), (D), (E)
Mounting
Mounting (A),
(C), (B)
(D), (E) 40
60
Please leave 4mm space from the surfaces and leave Alpha II
4mm space from the sides of PCB, especially from the sol-
20
Mounting (C), (D), (E)
der surface, 8mm space is necessary. If the space is not
40
DLP
20 30 40 50 60 70
0
20
-10 0 10 20 30 40 50 60 70 enough, the specification of insulation and withstand volt-
nt Temperature(℃) Ambient Temperature(℃) age will not be satisfied.
0 20 30 40 50 60 70
0
-10air 0
Forced 10 20Average 40 (%)
30 Load 50 60 70
FPS
NOT LESS THAN 4mm
ent Temperature(℃) Ambient Temperature
Mounting
A, B, C, D, E (℃)
Ta
−10 to 60℃ 100 NOT LESS
70℃ 70 THAN 4mm Genesys
NOT LESS NOT LESS
120
THAN 4mm THAN 4mm
Mounting (A) With chassis and cover type
100
120
HK-A
Average Load(%)
NOT LESS
Mounting (A) 80 NOT LESS THAN 4mm THAN 8mm
100
C), (E) Mounting (A), (B), (C), (D), (E)
HWS
Average Load(%)
60
80 FG should be connected to the earth terminal of the appa-
(C), (E)
Mounting (B), (D) Mounting (A), (B), (C), (D), (E)
ratus. If not, the EMI noise and output noise will increase.
40
60 JWS-P
Mounting (B), (D) WIRE
20
40
METAL SPACERS
0
20
JWT
20 30 40 50 60 70 -10 0 10 20 30 40 50 60 70
nt Temperature(℃) Ambient Temperature(℃) CHASSIS (CONDUCTOR)
0
0 20 30 40 50 60 70 -10 0 10 20 30 40 50 60 70 Hatching area is maximum permissible area of metal part MTW
ent Temperature(℃) Ambient Temperature(℃)
for mounting. (9mm from each PCB corners)
Forced air Average Load(%)
Ta
Mounting
A, B, C, D, E
9 9
RKE
−10 to 50℃ 100
9
9
60℃ 70
*Recommended minimum air velocity: 0.7m/s (Measured at component side of RKY
PCB, air must flow through component side.) As a reference for forced air cool-
ing, let air flow so that the transformer T1 core temperature is lower than 85℃ .
RTW
T1
Test point
9
9
(CORE)
9 9
(F) & (G) are prohibited as shown in section 4-1. The pow-
er supply can be mounted through holes A or B. VS
2 Mounting Method
A : Embossed tapped and countersunk holes by 4-M4
PCB type VS-P
screws
9
COMPONENT SIDE
B
ZWQ
B
A A
HEIGHT MORE ZWS
THAN 8mm
SPACER
Note: For cases where the unit is often under vibration Mounting (F), (G), (H), ( I ) are prohibited.
CHASSIS
condition, fix with isolated spacer (non conductive), at the For mounting method (J), (K), (L) below, the vibration spec-
A CN1
A
5th hole, near C6 on the PCB. ification is B6.9m/s2, mounted through holes CN51
C or D.
The 5th hole diameter: φ3.5mm Note : Output derating COMPONENT SIDE
for mounting (J) is same Bas mount-
PCB thickness: 1.6mm Ing B(C). Output derating for mounting (K) is same
Maximum spacer outer diameter: φ7mm
A A
as mounting (E). Output derating for mounting (L) is
ZWS
-PAF
same as mounting (D).
高さ8mm以上の
間座
・All specifications are subject to change without notice. A-467
ZWS150PAF SERIES
(J) (K) (L) C: 2-φ4.5 holes and 2-R2.25 slot holes by 4-M4 screws
Output Input
Input
(For/SL and /SA models, these holes can not be used.)
D: Embossed tapped and countersunk holes by 2-M4
Input Output screws.
Alpha II
DLP
5. Wiring Method
FPS
●T he output load line and input line shall be separated of input connector and mountable FG to ground terminal
and twisted to improve noise sensitivity. of equipment.
Genesys
● Use all lines as thick and short as possible to make ● Recommened screw torque is 0.49N.m (5kg.cm)
lower impedance. ● Select the wire materials to adapt the MOLEX and J.S.T
HK-A ●N oise can be eliminated by attaching a capacitor to the connector as follows.
load terminals INPUT: AWG#22 - #18
HWS ● For safety and EMI considerations, connect FG terminal OUTPUT: AWG#22 - #18
JWS-P
6. External Fuse Rating
JWT Refer to the following fuse rating when selecting the exter- the fuse according to input current (rms.) values under the
nal fuses that are to be used on input line. Surge current actual load condition.
MTW flows when line turns on. Use slow-blow fuse or time-lag ZWS150PAF: 5A
type fuse. Do not use fast-blow fuse. Fuse rating is speci-
fied by in-rush current value at line turn-on. Do not select
RKE
RKY
7. Before concluding that the unit is at fault...
RTW Before concluding that the unit is at fault, make the follow- check if the Remote ON/OFF control connector is not
ing checks. opened.
SWT ● Check if the rated input voltage is connected. ● Check if the output current and output wattage do not
● Check if the wiring of input and output is correct. exceed specification.
● Check if the wire material is not too thin. ● Audible noise can be heard during dynamic-load opera-
UNA
● Check if the output voltage control (V.ADJ) is properly tion.
adjusted. ●A
udible noise can be heard when input voltage wave-
VS ● If you use function of the Remote ON/OFF control, form is not sinusoidal wave.
VS-P
8. Notes
ZUP
1) Over voltage Category II. 2) Radio Interference Suppression Test is not performed.
ZWD-
PAF
ZWQ 9. Repair
In case of damage or repair of this product, please return
ZWS to our service center or factory.
ZWS
-PAF
RKY
1 ZWS240PAF
+R
1 2
CN2
−R
VR51
CN52
RTW
−R +R
2 1
1 FG −
8
7
4 N
6
5
4
SWT
6 L
3
CN1 2
1
CN51+
UNA
VS
① L: AC Input terminal (pin 6 of CN1) ● Input & output connector (MOLEX) VS-P
Live line (fuse in line) (also for option model /L, /A)
② N: AC input terminal (pin 4 of CN1)
Connector Housing Terminal Pin
Neutral line ZUP
5239-06
③ FG: Input terminal FG (pin 1 of CN1) (CN1)
Input 5414-30B or 2139-06 5167PBTL
Safety earth (Frame Ground) or 3069-06
+R
1 2
−R
ZWD-
Connect to safety ground of apparatus or equipment. CN2 CN52
VR51
5239-08 PAF
−R +R
2 1
④ FG: Frame Ground (Connected to pin 1 of CN1) CN1 Output(CN51) 5273-08A or 2139-081
−
5167PBTL
5 FG
or 3069-08
2
NOTE A: For cover & chassis type (model: ZWS240PAF/A), remote ON/OFF control cannot be used.
VR51
−R +R
2 1
CN1
FG CN51 −
2 ZWS240PAF/J
+R −R
1 2
CN2 CN52
VR51
−R +R
2 1
CN1 −
1
5 FG 2
3
3 N 4
5
1 L
6
+R −R 7
1 2
CN2 CN52
8
VR51
−R +R
CN51+
2 1
1 FG −
8
Alpha II
7
6
4 N
5
4
6 L
3
CN1 2
1
CN51+
DLP
① L: AC Input terminal (pin 1 of CN1) ●Input & output connector (J.S.T)
Live line (fuse in line) (also for option model /JL, /JA)
FPS ② N: AC input terminal (pin 3 of CN1)
Connector Housing Terminal Pin
Neutral line
(CN1)
Input B3P-5-VH VHR-5N SVH-21T-P1.1
③ FG: Input terminal FG (pin 5 of CN1)
Genesys Safety earth (Frame Ground)
Output(CN51) B8P-VH VHR-8N SVH-21T-P1.1
*Output current of each connector pin must be less than 5A.
Connect to safety ground of apparatus or equipment.
*Hand crimping tool : YC-160R (J.S.T)
HK-A ④ FG: Frame Ground (Connected to pin 5 of CN1) +R
1 2
CN2
−R
CN52
−R +R
2 1
CN1
VR51
CN52
−R +R
2 1
within MAX 8mm. CN1
L
Connector Housing 1 +
−
Terminal Pin
5 FG
⑤ CN2: ON/OFF control terminal (primary circuit)
2
3
1
N
L
B2B-XH-AM XHP-2
4
5
6
BXH-001T-P0.6
or SXH-001T-P0.6
⑥ +: +Output terminal
7
8
*CN2 is normally shorted by JM-2W-96 (J.S.T).
CN51+
JWT ⑦ −: -Output terminal *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T)
⑧ V.ADJ: Output voltage adjust trimmer (VR51)
The output voltage rises when a trimmer is turned
MTW clockwise.
⑨ CN52: ON/OFF control terminal (secondary circuit)
(For power supply output on and off control with an
RKE external signal.) with an external signal.)
See NOTE A +R
1 2
−R
CN52
CN2
NOTE A: For cover & chassis type (model: ZWS240PAF/JA), remote ON/OFF control cannot be used.
CN1 VR51
−R +R
RKY
2 1
FG CN51 −
3 ZWS240PAF/T
N
RTW L
+R
1 2
−R +
CN2 CN52
VR51
−R +R
2 1
CN1
FG CN51 −
SWT N
UNA
+
VS
4 ZWS240PAF/S
+R −R
1 2
CN52
CN1 CN2
VR51
−R +R
2 1
FG CN51 −
Alpha II
DLP
① L: AC Input terminal L (M4 screw) ● Input & output connector (EMUDEN)
Live line (fuse in line) (also for option model /SL, /SA)
② N: AC input terminal N (M4 screw)
Connector
FPS
Neutral line
(CN1)
Input T6969-A
③ FG: Input terminal FG (M4 screw)
Safety earth (Frame Ground)
(CN51)
Output T7093-A Genesys
Connect to safety ground of apparatus or equipment.
④ FG: Frame Ground ● Connector for remote ON/OFF control: HK-A
Must be connected to electrically safety ground of ap-
CN2, CN52 (J.S.T)
paratus or equipment by electrically conductive spac-
ers. The mounting surface of the spacer should be Connector Housing Terminal Pin HWS
within MAX 8mm.
BXH-001T-P0.6
⑤ CN2: ON/OFF control terminal (primary circuit) B2B-XH-AM XHP-2
or SXH-001T-P0.6
See NOTE A JWS-P
*CN2 is normally shorted by JM-2W-96 (J.S.T).
⑥ +: +Output terminal (M4 screw) *Hand crimping tool: YC-110R (J.S.T) or YRS-110 (J.S.T)
⑦ −: -Output terminal (M4 screw) JWT
⑧ V.ADJ: Output voltage adjust trimmer (VR51)
The output voltage rises when a trimmer is turned
clockwise. MTW
⑨ CN52: ON/OFF control terminal (secondary circuit)
(For power supply output on and off control with an
external signal.) RKE
See NOTE A
NOTE A: For cover & chassis type (model: ZWS240PAF/SA), remote ON/OFF control cannot be used. RKY
RTW
ZWD-
ZWS240PAF PAF
+R −R
1 2
CN52
FG CN2
VR51
ZWQ
−R +R
2 1
EARTH
1 FG
COMPONENT SIDE 8
7
− 6
LOAD
4 N
5
INPUT OUTPUT
85VAC- CN1
6 L
4
+ 3
2
ZWS
265VAC 1
CN51
ZWS
-PAF
+R −R
1 2
CN2 CN52
VR51
A-471
−R +R
2 1
EARTH
5 FG
COMPONENT SIDE 2
− 3
AD
3 N 4
CN2 CN52
VR51
−R +R
2 1
+R −R
CN1 1 2
ZWS240PAF SERIES
CN2 CN52
1
5 FG
COMPONENT SIDE VR51 2
−R +R
EARTH
2 1
− 3
LOADLOAD
3 N
CN1 4
INPUT OUTPUT
1
EARTH
5 FG
1 L COMPONENT SIDE 5
2
6
85VAC- 3 N
+ 3
− 7
4
265VAC INPUT OUTPUT 8
ZWS240PAF/J
5
1 L CN51
6
85VAC- +R −R
+
7
265VAC 1 2
CN2
8
CN52
VR51 CN51
−R +R
2 1
CN1
1
EARTH
5 FG
COMPONENT SIDE 2
− 3
LOAD
3 N 4
1 L
INPUT OUTPUT 5
6
85VAC- +
7
265VAC 8
CN51
Alpha II
DLP
ZWS240PAF/T FG
+R
1 2
CN2
−R
CN52
VR51
−R +R
2 1
CN1
+R −R
COMPONENT SIDE
FPS
1 2
FG FG CN51
CN52
CN2
EARTH VR51
−R +R
2 1
CN1
−
COMPONENT SIDE
LOADLOAD
N CN51
FG
INPUT OUTPUT
EARTH +
L −
Genesys 85VAC- N
INPUT OUTPUT
265VAC +
L
+R −R
85VAC- FG
1 2
CN52
265VAC CN2
VR51
−R +R
2 1
CN1
LOAD
N
INPUT OUTPUT
L +
HWS 85VAC-
265VAC
JWS-P
ZWS240PAF/S
JWT FG
+R
1 2
CN2
−R
CN52
VR51
−R +R
2 1
CN1
FG FG COMPONENT SIDE +R
1 2
CN2
−R
CN51
CN52
EARTH VR51
−R +R
2 1
CN1
MTW −
LOADLOAD
N
FG COMPONENT SIDE OUTPUT CN51
INPUT
EARTH L
+
−
N
85VAC- OUTPUT
265VAC INPUT +
RKE
L
85VAC- +R
1 2
−R
CN52
265VAC FG CN2
VR51 −R +R
2 1
CN1
EARTH
RKY −
LOAD
N
OUTPUT
INPUT +
L
85VAC-
265VAC
RTW
SWT
3. Explanation of Functions and Precautions
3 Inrush Current
This series has used Power Thermistor to protect the
6 Over Temperature Protection (OTP)
circuit from Inrush Current. Please carefully select input OTP circuit is built into the power supply to prevent power
ZWS switch and fuse in cases of the high temperature and re- supply from damage when ambient temperature over the
-PAF
input the power. specification.
(B)
Remote ON/OFF Control
Peak Output Current Remote ON/OFF control (CN2, CN52) function is avail-
For ZWS240PAF series, the peak output current should able. Using this function allows the user to turn the output
satisfy the conditions below: on and off without having to turn the AC input on and off.
1) Should not exceed the rated peak current in the speci- Remote ON/OFF control can be used by following
ZWS
-PAF
fications. (eg. 20A for ZWS240PAF-24) 2 modes. However, for Cover and Chassis type (eg.
ZWS240PAF/A, /JA, /TA, /SA) cannot be used.
Power
Supply
SWT
Withstand
Voltage
UNA Tester
Withstand Voltage Tester
[CN52] The control mode is shown below.
VS +R & -R terminal condition Output condition
SW ON (Higher than 4.5V) ON
VS-P SW OFF (Lower than 0.8V) OFF
ZUP
4. Mounting Directions
ZWD-
PAF
1 Output Derating according to the Mounting Directions ● PCB type
Input Output
Input
ZWQ Recommended standard mounting method is (A). Method
(B), (C), (D), (E) are also possible. Mounting (F), (G), (H), Component Input
Input
ZWS (I) are prohibited. Please do not use installation method Output
(F), where the PCB will be on the top side and heat will
be trapped inside the unit. Refer to the derating below. In (A)Standard Mounting (B) (C) (D) (E) (F)Prohibited
the following derating curve, average load (%) is percent
of maximum output load (both maximum output current and
maximum output power in specifications). Do not exceed
the load deratings.
ZWS
-PAF
Input
Input
Output 100
(%)
80
(A)Standard Mounting (B) (C) (D) (E)
Average Load
60 Mounting
(A), (B), (C), (D), (E) Alpha II
40
20
DLP
(F)Prohibited (G)Prohibit (H)Prohibit (I)Prohibit
0
-10 0 10 20 30 40 50 60 70 FPS
Ambient Temperature
(℃)
Output Derating
● Convection cooling Forced air Average Load(%) Genesys
PCB type and with chassis type
Mounting
Ta A, B, C, D, E
−10 to 60℃
120 120
Mounting
(A),(B),(C),(D)
70℃,(E)
100
70
HK-A
100 100
(240W) (300W)
With chassis and cover type HWS
Average Load(%)
80 Mounting
(A) 80
120 (240W)
120 100
Mounting
(B) Average Load(%)
Mounting
(A),(B) ,(C),(D),(E)
60 60 JWS-P
Average Load(%)
100 100
(240W) Mounting
(C)
(D)
, (300W)
80
40 40
Average Load(%)
Mounting
(A) (E)
80 Mounting 80
(240W)
60 Mounting JWT
(A), (B), (C), (D), (E)
Average Load(%)
20 Mounting
(B) 20
60 60 1.5m/s
40
0.7m/s
0 Mounting
(C) (D)
, 0 MTW
40 -10 0 10 20 30 40 50 60 70 40 -10 0 10 20
20
30 40 50 60 70
Mounting
(E)
Ambient Temperature(℃) Ambient Temperature(℃)
20
Convection Average Load(%)
20
1.5m/s 0 RKE
0.7m/s -10 0 10 20 30 40 50 60
Mounting
Ta0 A B C D E 0 Ambient Temperature
(℃)
-10 0 10 20 30 40 50 60 70 -10 0 10 20 30 40 50 60 70
−10 to 25℃
Ambient
100 100 100
Temperature (℃)
100 100
Ambient Temperature (℃) RKY
30℃ 100 100 100 100 87.5 Forced air Average Load(%)
35℃ 100 100 90 90 75 Mounting
Ta A, B, C, D, E
40℃ 100 93.3 80 80 62.5
45℃ 100 86.7 70 70 50
−10 to 50℃ 100 RTW
120 120 60℃ 70
50℃ 86.7 80 60 60 37.5 Mounting(A),(B),(C),(D) ,(E)
55℃ 73.3 60Mounting
50 (A) 50 25 *Recommended minimum air velocity: 0.7m/s (Measured at component side of
(240W)
10060℃ 60 40 40 40 12.5
(300W)
100 PCB, air must flow through component side). As a reference for forced air cool SWT
ing, let air flow so that the transformer T1 core temperature is lower than 80℃
With chassis 80
and cover type
Average Load(%)
80 C6 T1
(240W) Test point
120 120
UNA
(%)
Mounting
(A)
,(B)
,(C)
,(D)
,(E) (CORE)
60 Mounting
(A) 60
100 Mounting
(B),(C) 100
Average Load
(240W) (300W)
40 40 PCB VS
(%)
80 80
Mounting
(D),(E) (240W)
(%)
20 20
Average Load
1.5m/s
60
Mounting
(B) ,(C)
60
0.7m/s VS-P
Average Load
0 0
40 -10 0 10 20 30 40 50 60 70 40 -10 0 10 20 30 40 50 60 70
Ambient
Mounting
(D) Temperature(℃)
,(E) Ambient Temperature(℃) ZUP
20 20
1.5m/s
0.7m/s
0 0 ZWD-
-10 0 10 20 30 40 50 60 70 -10 0 10 20 30 40 50 60 70 PAF
Ambient Temperature(℃) Ambient Temperature(℃)
Convection Average Load(%) ZWQ
Mounting A B C D E
Ta
−10 to 5℃ 100 100 100 100 100
15℃ 100 100 100 80 80 ZWS
25℃ 100 80 80 60 60
50℃ 50 30 30 10 10
ZWS
-PAF
9
FG
2 Mounting Method WIRE
METAL
SPACERS
PCB type HEIGHT MORE
THAN 8mm
Please use the mounting hole (5 holes of φ3.5) and insert
SPACER CHASSIS
(CONDUCTOR)
9
the spacer (MAX φ8.0) of height over 8mm to lift the unit. Hatching area 9is maximum permissible area
9
of metal part
Also use all 5 mounting holes for the unit installation. The for mounting.
vibration spec is the value taken when the unit is raised by 9 9
9
Alpha II 8mm spacers.
DLP
9
9 9 9
FPS HEIGHT MORE
THAN 8mm
For chassis option /L, chassis & cover option /A
SPACER Recommended mounting by following holes A or B, to meet
Genesys Please leave 4mm space from the surfaces and leave 19.6m/s2 vibration specification. Mounting direction (F) &
CHASSIS
4mm space from the sides of PCB, especially from the sol- (G) are prohibird
A CN1 as shown in section 4-1.
A
B
HK-A der surface, 8mm space is necessary. If the space is not CN51
COMPONENT SIDE
B
NOT LESS B
MTW NOT LESS THAN 8mm A A
THAN 4mm
ZUP
ZWD-
PAF 6. External Fuse Rating
ZWQ Refer to the following fuse rating when selecting the exter- ZWS240PAF: 6.3A
nal fuses that are to be used on input line. Surge current
ZWS flows when line turns on. Use slow-blow fuse or time-lag
type fuse. Do not use fast-blow fuse. Fuse rating is speci-
fied by in-rush current value at line turn-on. Do not select
the fuse according to input current (rms.) values under the
actual load condition.
ZWS
-PAF
FPS
8. Notes Genesys
HWS
9. Repair JWS-P
RKE
RKY
RTW
SWT
UNA
VS
VS-P
ZUP
ZWD-
PAF
ZWQ
ZWS
ZWS
-PAF