Gas Turbine-Generator Summary: 19. No. of Cross Flame Tube: 19. There Are Two Blinds in 18 and 19
Gas Turbine-Generator Summary: 19. No. of Cross Flame Tube: 19. There Are Two Blinds in 18 and 19
1. Model : M701F
2. Turbine Manufacturer: Mitsubishi Heavy Industries, Japan.
3. Generator type: Hydrogen cooled, 247 MW, 2 Pole, 3000 RPM
4. Generator Manufacturer: MELCO
5. Rated Voltage: 16KV
6. Fuel: Natural Gas
7. Turbine stage: 4 reaction stages
8. Compressor stage: 17 stages axial compressor
9. No. of Combustor : 20
10. No. of Fuel Nozzle: Main Nozzle: 20 and Pilot Nozzle: 20
11. In each combustor, there are 8 premix main nozzles and 1 pilot diffusion nozzle.
12. There are two type combustors: STD A and STD B. No of STD A Combustor is 16 and STD B Combustor is
4.
13. Combustion Temperature: 1350 deg.C
14. No. of Transition piece: 20
15. No. of Bypass Elbow: 20
16. No. of Marman Coupling: 38
17. Igniter Position: Combustor No. 8 and Combustor No: 9
18. Flame Detector Position: Combustor No. 18 and Combustor No: 19
19. No. of Cross Flame Tube: 19. There are two blinds in 18 and 19.
20 1
19 2
3
18
4
17
16 5
15 6
14 7
8
13
12 9
11 10
20. For surge control, 6th and 11th stage has air bleed line.
21. Seal air for bearing is extracted from 6th stage of compressor. Seal air is provided for No. 1 (Exhaust
side) and No. 2 (Compressor side bearing).
22. Cooling air for turbine rotor:
Direct discharge is used for Row#1 vane for cooling.
Compressor bleed form HP, IP and LP section are used to provide cooling air for turbine blade
ring cavity of turbine row 2, 3, 4 respectively. This will cool stage 2, 3, 4 vane segments and ring
segments.
23. There are 5 bearings in turbine and generator.
Bearing No#1: Turbine side bearing is two pad journal bearing. Journal Clearance (Diametrical)
is 1.30 mm to 1.73 mm
Bearing No#2: Compressor side bearing is two pad journal bearing housed in inlet casing. Both
ends have floating type oil seal. Two babbited pads are supported by hardened spherical pin. A
stop pin is for stopping the rotation of the bearing.
Properties Air Flow Class Dust Efficiency at Initial Final Initial Final
Rate Holding (0.3-1.0μ) Resistance(w.g.) Resistance Pressure Pressure
Capacity (w.g.) Drop (Pa) Drop (Pa)
Pre-filter 2000 m3/hr G-3 443 31 250
gm/Sq-m
1st stage 3400 m3/hr F-6 3000 gm 28.91% 0.568 2.5 125 650
Filter
2nd stage 3400 m3/hr F-8 3000 gm 76.87% 0.636 2.5 145 650
filter
3rd stage 2300 m3/hr HEPA 99.97% at 0.3 0.9835(245 Pa) 250 650
filter μm
CLASSIFICATION Arrestance or Dust Spot Efficiency US ASHRAE 52.2 European Union EN779 Class Application
PRE Filter AFI <65 % MERV 1 G1 Am< 65% Gross filter, domestic and commercial
(G Class) AFI 65%-70% MERV 2 G2 65%≦Am< 80%
AFI 70%-75% MERV 3
AFI 75%-80% MERV 4
AFI 80%-85% MERV 5 G3 80%≦Am<90% Commercial, industrial, paint shop
AFI 85%-90% MERV 6
NBS 25%-30% MERV 7 G4 90%≦Am
NBS 25%-30% MERV 8
MEDIUM Filter NBS 40%-45% MERV 9 F5 40%≦Em< 60% IAQ concerned commercial & industrial, medical
(F Class) NBS 50%-55% MERV 10
NBS 60%-65% MERV 11 F6 60%≦Em< 80%
NBS 70%-75% MERV 12
NBS 80%-85% MERV 13 F7 80%≦Em< 90% IAQ concerned commercial, industrial, medical, food etc
NBS 90%-95% MERV 14 F8 90%≦Em< 95%
NBS>95% MERV 15 F9 95%≦Em
MERV 16
HEPA Filter ≧95% at 0.3μm n/a H10 ≧85% at MPPS All types of clean rooms
(H Class) ≧98% at 0.3μm H11 ≧95% at MPPS
≧99.97% at 0.3μm TYPE A
≧99.99% at 0.3μm TYPE C H12 ≧99.5% at MPPS
≧99.995at 0.3μm H13 ≧99.95% at MPPS
≧99.999%at 0.3μm TYPE D H14 ≧99.995% at MPPS
ULPA Filter ≧99.9995%at 0.3μm TYPE F U15 ≧99.9995% at MPPS super clean room
(U Class) ≧99.99995%at 0.3μm U16 ≧99.99995% at MPPS
≧99.999995%at 0.3μm U17 ≧99.999995% at MPPS
26. Show the CPFM Sensor positions.
Answer:
27. What are the materials for gas turbine hot parts?
Answer: