Professional Documents
Culture Documents
Gas Spring PDF
Gas Spring PDF
Gas Spring PDF
N2 gas springs
www.pascaleng.co.jp
Pascal N2 gas springs
Ensures high grade of the parts with high degree of accuracy
1
Page
Models at-a-glance 3・ 6
model DNK 9 ∼ 16
model DNR 17 ∼ 25
model DNP 27 ∼ 30
model DNA 31 ∼ 38
Caution in use 39 ・ 40
Piping 41 ∼ 50
2
Models at-a-glance
ø60 ø60
158
ø95 ø95
Refer to Page 7 and 8 for the difference between model DNK and DNR.
3
Models at-a-glance
ø50
200
Dust seal
Rod guide
ø63
Rod seal
520
Dust seal
25
Piston guide
Rod guide
Piston guide
135
Piston seal
ø75 ø95
Bore seal Piston & Rod guide Rod seal Piston & Rod guide
4
Specificationls at-a-glance
Cylinder Initial
Model & Structure Size diameter force
mm kN 6 10 13 16
0350 32 3.62 60 66 72
0500 38 4.71 60 66 72
0750 45 7.36 73 79
model
1000 50 9.24 78 84
DNK
1500 63 15.3 78 84
Page → 9
2400 75 23.9 91
4200 95 42.4 94
Standard
6600 120 66.3 104
0350 32 3.62 50 56 62
0500 38 4.71 50 56 62
0750 45 7.36 52 58 64
model
1000 50 9.24 64 70
DNR
1500 63 15.3 70 76
Page → 17
2400 75 23.9 77
4200 95 42.4 90
Compact body
6600 120 66.3 100
0420 25 4.71 56 70 91
model 1000 38 10.6 61 78 100
DNP 1800 50 18.8 66 80 106
0250 38 2.65
model 0500 45 4.71
DNA 0750 50 7.36
3000 95 29.5
5
Specificationls at-a-glance
97 109 123 135 159 185 209 219 259 309 G1/8 51 58
100 112 126 138 162 188 212 222 262 312
110 122 136 148 172 198 222 232 272 322
116 128 142 154 178 204 228 238 278 328
106 118 132 144 168 194 218 228 268 318 G1/8 51 58
116 128 142 154 178 204 228 238 278 328
120
135
135
135 ー ー
145
155
165
440 520
460 540
6
model DNK / model DNR Threaded hole depth at the bottom
● The threaded hole depth is different between model DNK and model DNR.
ø28 ø28
152
138
ø50 ø50
● Threaded hole size at the bottom ● The model to be mounted with flange
Model Threaded hole size Model Threaded hole size
DNK0350 DNR0350
2-M6 depth 11 2-M6 depth6
DNK0500 DNR0500
DNK0750 2-M8 depth16 DNR0750
DNK1000 2-M10 depth16 DNR1000 2-M8 depth6
2-M8 depth16 DNR1500
DNK1500
4-M8 depth16 DNR2400 4-M8 depth6
DNK2400
DNK4200 ● The model to be mounted by screws securely
4-M12 depth16
DNK6600
Model Threaded hole size
DNK9500
DNR4200 4-M 8 depth13
DNR6600 4-M10 depth13
DNR9500 4-M10 depth16
7
model DNK / model DNR Piping port size
● The piping port size is different between model DNK and DNR.
ø28 ø28
152
138
Piping port : G1/8 Piping port : M6
ø50 ø50
DNK0350 DNR0350
M6
DNK0500 DNR0500
DNK0750 DNR0750
M6
DNK1000 DNR1000
DNK1500 DNR1500
DNK2400 G1/8 DNR2400
DNK4200 DNR4200
DNK6600 DNR6600 G1/8
DNK9500 DNR9500
● For the model DNR2400 and smaller, the mount face should
be milled off to secure the space for the adapter due to the
thin wall at the bottom. (Refer to page → 59)
8
model DNK Structure
model DNK
DNK
model
Cylinder
Oil
Check valve
DNK
For charging type, specify "-T". common to domestic and overseas (outside Japan) use.
DNK 1500 50 FC T (Charging pressure is not necessary to specify) ※2
model
OS Specify - OS in case self-contained gas spring without gas charge.
※1. Choose one of the recommended gas pressure levels shown above. For the charging pressure other than above, specify the pressure
to one digit after the decimal point. The gas charging range is 3.4 MPa to 15 MPa at 20℃.(3.4∼18MPa for DNK0350 only)
※2. Check valve is not mounted at shipment.
※1. Choose one of the recommended gas pressure levels shown above. For the charging pressure other than above, specify the pressure
to one digit after the decimal point. The gas charging range is 3.4 MPa to 15 MPa at 20℃.(3.4∼18MPa for DNK0350 only)
※2. Check valve is not mounted at shipment.
DJF 063 FC
Flange Code (Refer to page → 13∼16)
FC, FS, BK, BL
DNK
32 32 42.4 66.9 1.58 3.4 126 94 D = 95 Z = 24
38 38 42.4 67.7 1.60 3.6 138 100
DNK4200- 50 50 42.4 68.8 1.62 3.9 162 112 E = 11.4 P = M8 depth 6
model
63 63 42.4 69.6 1.64 4.2 188 125
75 75 42.4 70.1 1.65 4.5 212 137 J = 2.5
80 80 42.4 70.2 1.66 4.6 222 142
100 100 42.4 70.7 1.67 5.1 262 162 Piping port = G1/8(BSPP)
125 125 42.4 71.2 1.68 5.7 312 187
※ made to order Showing the figures at initial charging pressure 15MPa at 20℃ . (18MPa for model DNK0350 only)
2-"M"
P.C.D."U"
P.C.D.35
C
N
□24.7 □C
Z
-0.5
0
Model C M Model C U M
L
R "J"
DNK0350 20 M6 depth 11 DNK2400 38.1 53.8 M12 depth 16
H
4-øM
Mounting hole
DNK
model
P.C.D. C
□B
øD
Retaining ring
H
+1
ø E +0.5
Note: Fc flanges are designed with sufficient strength to accommodate the loading.
(The flange should support the load by its full mounting face, and should be mounted by 4 screws.)
B C D E H J M Mass
Gas spring model Flange model
mm mm mm mm mm mm mm kg
4-øM
Mounting hole
DNK
model
P.C.D. C
□B
□A
Retaining ring
H
+1
ø E +0.5
Note: Fs flanges are designed with sufficient strength to accommodate the loading.
(The flange should support the load by its full mounting face, and should be mounted by 4 screws.)
A B C E H J M Mass
Gas spring model Flange model
mm mm mm mm mm mm mm kg
From April 2014, 2-piece structured model BK has been available for sale. It is interchangeable
with the old model (BU) because its outer dimensions remain unchanged.
DNK
4-øN 4-øN
Mounting hole Mounting hole
P.C.D. C P.C.D. C
K
K
□B
□B
□A
□A
Spot facing
10
25
G
A B C G K N Mass
Gas spring model Flange model
mm mm mm mm mm mm kg
DNK
4-øN
Mounting hole
model
P.C.D. C
K
□B
□A
Beware of the spot facing space.
The depth to be strictly controlled. Press slide
There is a risk of damage or loose screw of
the flange in case the gap between press Retaining ring
slide and the bottom of gas spring exists.
Model BL is not compatible with other
suppliers flange due to different thickness.
+0.1
25
0
G
A B C G K N Mass
Gas spring model Flange model
mm mm mm mm mm mm kg
model DNR
DNR
model
Cylinder
Oil
Check valve
DNR
Gas Spring Stroke S (mm) (Refer to page → 19 and 20)
model
10, 13, 16, 19, 25, 32, 38, 50, 63, 75, 80, 100, 125
※1. Choose one of the recommended gas pressure levels shown above. For the charging pressure other than above, specify the pressure
to one digit after the decimal point. The gas charging range is 3.4 MPa to 15 MPa at 20℃.(3.4∼18MPa for DNR0350 only)
※2. Check valve is not mounted at shipment.
※1. Choose one of the recommended gas pressure levels shown above. For the charging pressure other than above, specify the pressure
to one digit after the decimal point. The gas charging range is 3.4 MPa to 15 MPa at 20℃.(3.4∼18MPa for DNR0350 only)
※2. Check valve is not mounted at shipment.
DJF 063 FC
Flange Code (Refer to page → 21∼25)
FC, FS, SC, KA, KB
DNR
19 19 66.3 94.3 1.42 5.4 106 87 K = 75 T = 10.5
25 25 66.3 97.7 1.47 5.5 118 93
32 32 66.3 100.3 1.51 5.8 132 100 D = 120 J = 2.5
model
38 38 66.3 102.0 1.54 6.1 144 106 B = 112 N = 3
DNR6600- 50 50 66.3 104.4 1.57 6.6 168 118
63 63 66.3 106.1 1.60 7.1 194 131 E = 8 Z = 25.5
75 75 66.3 107.2 1.62 7.6 218 143
80 80 66.3 107.6 1.62 7.8 228 148 F = 7 P = M8 depth 6
100 100 66.3 108.9 1.64 8.6 268 168 Piping port = G1/8(BSPP)
125 125 66.3 109.9 1.66 9.6 318 193
※ made to order Showing the figures at initial charging pressure 15MPa at 20℃ . (18MPa for model DNR0350 only)
4-"M"
2-"M"
P.C.D."U"
C
N
□C
Z
-0.5
0
L
øB
0
øD -0.2
Piping port
Tips for stroke selection
4-øM
Mounting hole
P.C.D. C
DNR
model
□B
øD
Retaining ring
H
+1
øE +0.5
Note: Fc flanges are designed with sufficient strength to accommodate the loading.
(The flange should support the load by its full mounting face, and should be mounted by 4 screws.)
B C D E H J M Mass
Gas spring model Flange model
mm mm mm mm mm mm mm kg
4-øM
Mounting hole
P.C.D. C
DNR
model
□B
□A
Retaining ring
H
+1
øE +0.5
Note: Fs flanges are designed with sufficient strength to accommodate the loading.
(The flange should support the load by its full mounting face, and should be mounted by 4 screws.)
A B C E H J M Mass
Gas spring model Flange model
mm mm mm mm mm mm mm kg
4-øN
Mounting hole
P.C.D. C
DNR
model
□B
□A
T-T
T T
J
A B C J K N Mass
Gas spring model Flange model
mm mm mm mm mm mm kg
2-øP
Mounting hole
øG
F
DNR
B
model
E
T-T
2.3
T T
J
B E F G J P Mass
Gas spring model Flange model
mm mm mm mm mm mm kg
3-øP
120゜ Mounting hole
DNR
P.C.D. C
model
øE
T-T
T T
J
C E J P Mass
Gas spring model Flange model
mm mm mm mm kg
model DNP
DNP
model
Piston guide
Cylinder
Oil
Check valve
DNP
※ Choose one of the recommended gas pressure levels shown above. For the charging pressure other than above, specify the pressure
model
to one digit after the decimal point. The gas charging range is 3.4 MPa to 15 MPa at 20℃.
● Ask Pascal for the information about the DNP for hose-link system.
Example
Manifold base
K = 50 C = 28.3
10 10 46.8 76.3 1.63 1.7 80 70 D = 75 U = 40
DNP4700- 16 16 46.8 70.0 1.50 2.0 106 90 E = 18 M = M8 depth 9.5
K = 55 C = 36.8
10 10 75.4 121.2 1.61 3.2 90 80 D = 95 U = 52
DNP7500- 16 16 75.4 113.0 1.50 3.6 116 100 E = 21 M = M8 depth 12
K = 70 C = 48.1
10 10 117.8 174.7 1.48 5.8 100 90 D = 120 U = 68
DNP11800- 16 16 117.8 169.6 1.44 6.4 126 110 E = 22.5 M = M10 depth 13
J = 2.5 P = M8 depth 9
25 25 117.8 176.8 1.50 7.0 155 130
Z = 23.5
K = 90 C = 63.6
10 ※ 10 184.1 267.5 1.45 10.3 110 100 D = 150 U = 90
DNP18300- 16 ※ 16 184.1 262.2 1.42 11.3 136 120 E = 24.5 M = M10 depth 15
J = 2.5 P = M8 depth 10
25 ※ 25 184.1 274.1 1.49 12.4 165 140
Z = 25.5
※ made to order Showing the figures at initial charging pressure 15MPa at 20℃ .
M6 depth 9
17
DNP
S
1
model
Z
Charging port 2-M6 depth 11
L -0.5
0
R "J"
H
26
R "J"
E
0
øD -0.2
Charging port 4- M
P.C.D."U"
model DNA
DNA
model
Piston guide
Cylinder
Oil
Check valve
※1. Choose one of the recommended gas pressure levels shown above. For the charging pressure other than above, specify the pressure
to one digit after the decimal point. The gas charging range is 3.4 MPa to 15 MPa at 20℃.
※2. Check valve is not mounted at shipment.
DNA
model
For self-contained use, specify the gas charging pressure.
15 Gas Charging Pressure: 3.4, 6.9, 10.3, 13.7, 15 MPa ※1
For charging type, specify "-T". common to domestic and overseas (outside Japan) use.
DNA 0750 200 BF T (Charging pressure is not necessary to specify) ※2
※1. Choose one of the recommended gas pressure levels shown above. For the charging pressure other than above, specify the pressure
to one digit after the decimal point. The gas charging range is 3.4 MPa to 15 MPa at 20℃.
※2. Check valve is not mounted at shipment.
DJF 050 FC
Flange Code (Refer to page → 35∼38)
FC, FS, SC, HA
K = 25 P = M8 depth 13
160 160 7.36 11.7 1.59 2.7 415 255
D = 50 T = 12.5
DNA0750- 200 200 7.36 11.8 1.60 3.1 495 295 B = 43 J = 2
DNA
F = 7
K = 36 P = M8 depth 13
D = 75 T = 12
B = 67 J = 2.5
DNA1500- 160 160 15.3 23.1 1.51 6.4 430 270
N = 3 Z = 21
200 200 15.3 23.2 1.52 7.2 510 310
E = 8 C = 28.3
F = 7 U = 40
M = M8 depth 15
K = 50 P = M8 depth 13
D = 95 T = 12
B = 87 J = 2.5
DNA3000- 160 160 29.5 48.2 1.64 11.1 440 280
N = 3 Z = 24
200 200 29.5 49.0 1.66 12.6 520 320
E = 8 C = 42.4
F = 7 U = 60
M = M8 depth 13
K = 65 P = M8 depth 13
D = 120 T = 12
B = 112 J = 2.5
DNA5000- 160 160 49.8 79.4 1.60 18.9 460 300
N = 3 Z = 25.5
200 200 49.8 81.4 1.64 21.3 540 340
E = 8 C = 56.6
F = 7 U = 80
M = M10 depth 15
M6 depth 10
M8 depth 10
S
20
Z
M8 depth 13
R "J"
DNA
-0.5
0
L
model
20
4- M
F
T
P.C.D. "U"
øB
0
øD -0.2 Piping port
G1/8(BSPP)
□C
4-øM
Mounting hole
P.C.D. C
□B
øD
Retaining ring
H
DNA
+1
model
øE +0.5
Note: Fc flanges are designed with sufficient strength to accommodate the loading.
(The flange should support the load by its full mounting face, and should be mounted by 4 screws.)
B C D E H J M Mass
Gas spring model Flange model
mm mm mm mm mm mm mm kg
4-øM
Mounting hole
P.C.D. C
□B
□A
Retaining ring
H
DNA
J
+1
model
ø E +0.5
Note: Fs flanges are designed with sufficient strength to accommodate the loading.
(The flange should support the load by its full mounting face, and should be mounted by 4 screws.)
A B C E H J M Mass
Gas spring model Flange model
mm mm mm mm mm mm mm kg
4-øM
Mounting hole
P.C.D. C
□B
□A
T-T
DNA
model
T T
J
A B C J K M Mass
Gas spring model Flange model
mm mm mm mm mm mm kg
D G
E H
N
A
Stroke : S L min.
DNA
P
W
Q
model
4±0.1
+ 0.1
10 0 Alignment key U Backup key
Note1 : Use a key groove of the flange when installation to avoid the side-load to the gas spring.
Note2 : Install a back up key at the back of flange to prevent the flange mounting screws from damage.
DNA0250 ─
DNA0500 DJF045-HA 110+S 105+S 60 37 43 22 11 12 25 14 11 32 55 66 36 11 11 60 1.00
DNA0750 ─
DNA1500 ─
DNA3000 ─
DNA5000 ─
Storage/Transportation
● Storage
The gas spring should be stored in dust, sunlight and humid-free area.
● Transportation
Keep the gas spring in a way that it does not hit other gas spring. The scratches or dents made on the piston rod
surface may deteriorate the product s durability. (FIG. 1)
Operation/Mounting
● Do not attempt to dismantle the gas spring. High pressure gas is sealed inside and the parts may pop out
dangerously.
● Do not weld or cut the gas spring. Do not throw gas spring into the fire.
● Do not mount the gas spring by using the tap hole on the tip of piston.
Caution in Use
● Do not attempt to lift the whole die assembly by using the tap hole on the tip of piston rod. The tap hole is
provided for carrying and mount/dismount a single gas spring. (FIG. 2)
● The piston rod should be loaded to its full surface equally. If not, adjust the location of cushion pin or adaptor
plate to achieve it. (FIG. 3)
Operation/Mounting
● The gas spring is securely mounted by the screws from the bottom or by the flanges.
● Do not attempt the grinding or welding operation close to the gas spring. If it is inevitable, cover the gas spring
to protect them from debris or spatters. (FIG. 4)
● Do not use the gas spring under the high temperature environment. The maximum operating temperature is 70 ℃.
If the operational temperature is beyond room temperature (20℃), decrease the charging pressure until it
equals to the max. charging pressure (at 20℃). For the details, refer to Instruction Manual.
● Avoid side-load to the piston as much as possible. The side-load significantly shorten the service-life of gas
spring, specifically the mounting in lateral. The piston rod tends to lean because of its own weight in case of
lateral mount. (FIG. 5)
● Use gas spring within the recommended stroke range. Over stroke may cause the damage.
● Mount the gas spring to die lubricant free area. If the oil wet gas spring strokes, the oil may become the oil film
and intrude inside the cylinder. The accumulated draw oil may cause abnormal high pressure in the cylinder.
Especially the chlorine and soluble oils must be avoided as they will deteriorate sealing capability of packing
and shorter gas spring life. (FIG. 6)
Caution in Use
● Never use the gas spring under the condition of piston sudden release. Sudden release is very dangerous and
there is high risk of gas exhaust and serious damage of the cylinder.
● Exhaust the N 2 gas completely before disposal. Refer to page → 62 for gas discharging tool.
OIL
w
elo
b
°or
OIL
0.5
Hose Hose
Features of hose
O.D. ø5
I.D. ø2
Pascal Hose Link System is prepared for a handy and speedy piping for Gas springs.
Hose adaptor
Hose
DNK0750 ∼ DNK9500
DNA0250 ∼ DNA5000
Piping
DNK0350 ・ DNK0500
M6 × 1 → page 59
DNR0350 ∼ DNR2400
Notes
● Sealing tape or agent should not be used for hose adaptor (gas pressure shall be sealed by packing).
● For the mount of hose adaptor, be sure to use the tool to tighten it.
● Hose should be tightened till the lock nut o-ring is compressed by the hose nut.
It takes minimum space for the gas springs to be mounted in tandem however there should be
the time-lag when inflating the cylinders.
Gas spring
2
6
3
Piping
Inflating time can be equalized by the piping with the multi-coupling block since a big size of
gas spring has a large volume of cylinder and needs time to fully charge the gas.
3
Gas spring
1
Flange
5 4
Piping
ø5
ø19
34.3
L
L Mass L Mass
Model Model
mm g mm g
DNH-SS-0300 300 70
ø5
27.5
ø19
34.3 36
L
L Mass L Mass
Model Model
mm g mm g
Piping
DNH-SE-0220 220 90 DNH-SE-0700 700 90
DNH-SE-0300 300 90
ø5
27.5
36
L
L Mass
Model
mm g
DNH-EE-0150 150 70
DNH-EE-0160 160 70
DNH-EE-0170 170 70
DNH-EE-0180 180 70
DNH-EE-0190 190 70
DNH-EE-0200 200 70
DNH-EE-0210 210 70
Piping
DNH-EE-0220 220 70
DNH-EE-0230 230 70
DNH-EE-0240 240 70
DNH-EE-0250 250 70
DNH-EE-0260 260 70
DNH-EE-0270 270 70
DNH-EE-0280 280 70
DNH-EE-0290 290 70
DNH-EE-0300 300 70
Example
8
6
0.6
13 10
Hose clip
15
7
12 Mounting bolt M6
( not included )
Mass:5g
Piping
● Mount G-thread type adapter (Refer to Page → 51 to 58). Plug the open ports as necessity.
Mass 1300 g
125
65
79
42.7
7.7
G1/8(BSPP) Port
32 3-Plug (DNH-GP) included
● Mount G-thread type adapter (Refer to Page → 51 to 58). Plug the open ports as necessity.
● Mounting holes (4 places) are provided on the block however 2- place mount is feasible.
Number of port : 4 model DNH-F04 Number of port : 7 model DNH-F07 Number of port : 9 model DNH-F09
Mass : 400 g Mass : 750 g Mass : 1100 g
46 80 110
30 8 4-G1/8(BSPP) 30 25 7-G1/8(BSPP) 30 30 25 9-G1/8(BSPP)
8
50
50
34
34
30
46
11 15 15
4-ø6.8 64 8 4-ø11 94 8 4-ø11
30 30 30
140 170
30 30 30 25 10-G1/8(BSPP) 30 30 30 30 25 12-G1/8(BSPP)
50
50
34
34
15 15
124 8 4-ø11 154 8 4-ø11
30 30
Piping
Example
G1/8(BSPP)
12
4
Page → 52 Page → 52
Page → 53 Page → 54
Page → 55 Page → 56
Page → 57 Page → 58
● model DNH-GA(Check valve not built-in), model DNH-GB(Check valve built-in)are available.
12.3 9.2
29.5
29
Example
Straight adapter
model DNH-GA
Straight adapter
4.1
38.4
ø15 G1/8(BSPP)
20
43.1
30
20 2-S12.65×1.5 Width across flats : 17
21.65
20
20
Example
Piping
Gas spring
Straight
hose nut
13.5
28.6
ø15 G1/8(BSPP)
40
63.1
50
20 2-S12.65×1.5 Width across flats : 17
21.65
20
20
Example
Piping
Gas spring
Flange
Straight
hose nut
48.6
ø15 G1/8(BSPP)
20
43.1
30
20 2-S12.65×1.5 Width across flats : 17
43.3
20
20
Example
Piping
Gas spring
Straight
hose nut 90°hose nut
13.5
28.6
22.5
ø15 G1/8(BSPP)
40
63.1
50
20 2-S12.65×1.5 Width across flats : 17
43.3
20
20
Example
Piping
Gas spring
Flange
Straight
hose nut 90°hose nut
33.5
48.6
45.6 33.8
38.8
● Mount G-thread straight adapter. (Refer to Page → 52) Plug the open ports as necessity. (Refer to Page → 50)
20
43.1
30
20
65
20
Tightening torque : 13∼14.3 Nm Mass : 200 g
Example
90°hose nut
13.5
28.6
15
32.5 65.6
43.1 70.6
Plug
77.4
Straight adapter
54.9
48.1
43.1
20.6
● Mount G-thread straight adapter. (Refer to Page → 52) Plug the open ports as necessity. (Refer to Page → 50)
ø15 G1/8(BSPP)
4-G1/8(BSPP)
63.1
40
50
20
65
20
Tightening torque : 13∼14.3 Nm Mass : 220 g
Example
48.6
15
32.5 65.6
43.1 70.6 Plug
77.4
Long multi way adapter
Straight adapter
54.9
48.1
43.1
20.6
11.5 10
28
S12.65×1.5
Example
Gas spring
Straight adapter
DNH-MA
9.5
model
Straight adapter
model DNH-MA
43.5
Piping
Mill off the blue-colored area as shown below sketch in case of using hose adapter for model DNR.
Flange
min.40
Straight adapter
min.5
Hose system
● Hose should have a sufficient length with margin (it ● Be sue to use hose clips to avoid the abrasion by
is advised to have 10 or 20 % of margin on top of the contacting the sharp edges in the die. The hose is
overall length of piping). wobbled by not only stamping vibration but also the
pulse of gas-charge.
Piping
90°hose nut
③ ③ ②
Gas bottle
Control panel
Charging connector
Refer to Page → 62
Gas spring
Mass
No. Name Model Remark
Gas charging tools
③ High pressure hose 3HDKA68603 Max gas pressure 34MPa, Hose O.D.10.4mm, Length 3m 400
※ Make sure of thread size of the connection port of the gas bottle in case of using the regulator in overseas countries. It may be
different depending upon each country.
Gas charging and discharging kit (Their shape differs depending on the gas spring model.)
Adapter
Refer to page → 61 Gas can be exhausted
DNK1500 ∼ 9500 when screw in the port.
DNR4200 ∼ 9500 The connector can be
mounted by fingers.
Adapter
Refer to page → 61
DNK0750 ・ 1000 Gas can be exhausted
DNP1000 ∼ 18300 The connector can be when screw in the port.
DNA0250 ∼ 5000 mounted by fingers.
Adapter
Refer to page → 61 Gas can be exhausted
DNK0350 ・ 0500 when screw in the port.
Gas charging tools
※ Gas discharging tool is not available for model DNP0420. In case of disposal, drill a dia 2.5mm hole at the M6 tap at the bottom of
the DNP and then discharge N 2 gas completely. Wear safety glasses during discharging job.
Gas Charge/Discharge
● Charge Nitrogen (N 2 ) gas only. Never charge flammable, explosive gas and volatile liquid as they may cause an
explosion accident. (FIG. 1)
● The charging pressure should be below the designated pressure in the marking. (FIG. 2)
Gas charging range : 3.4 MPa∼15 MPa (at 20℃).
3.4 MPa∼18 MPa for model DNK0350 and DNR0350 only.
● Continue to charge gas till the sound of gas flow disappear even if the pressure gauge points the set pressure.
(FIG. 2)
● Gas charging should be done with the piston rod fully out. If piston rod retracted in the cylinder, start charging
as lower pressure as possible (0.5 MPa or lower) then increase the pressure gradually till the piston rod
extended out, in order to avoid personal injury and damages of facility and equipments. (FIG. 3)
● Exhaust the N 2 gas completely before disposal. Refer to page → 62 for gas discharging tool.
● Those gas springs for use outside Japan (specified as -OS) are shipped without gas. The user needs to charge
gas before use. After charging gas, the charging gas pressure should be recorded on the pressure indication
label of each gas spring by a permanent marker.
Pressure gauge
Gas charging tools
O2 Acetylene
Do not charge the
Hike up the pressure
Marking gas spring being
after the piton fully
MAX. ***MPa placed toward extends.
anyone.
DCS-21E-6
2016.07 Specifications are subject to change without prior notice.