Professional Documents
Culture Documents
Brosur Genteng M Class
Brosur Genteng M Class
Gypsum Board
Standard
Heat:3rm1
Moist:3rm1
Fire:3rm1
Echo:3rm1
~i
Elephant Gypsum Board transmits low heat and provides perfect insulating
property which could reduce heat generation and energy consumption
Heat Penetration of air conditioning system. Besides, the Micro-fiber insulation could be
Control additionally installed in contact with ceiling to further increase
AI
~ the thermal quality.
**Heat-Block Sheet provides extra heat penetration control capability.
Sound -JJ With sound absorption capability, Elephant Gypsum Board can be applied
Absorption
t v-y
.F.l as ceiling and wall to retard the penetration of 35-60 decibel noise.
Elephant Gypsum Board could be used as both Wall and Ceiling without
the need for beam installation. Set up through the drywall system,
Easy & Quick it can be quickly installed, leaving no dust to the area. Besides,the repair
Installation
or demolition work could be also simply processedat minimum disturbance
to other areas, even the occupied ones.
~
Setting up Elephant Gypsum Board can be quickly completed only after
Plain surface sealing the joints with Elephant Gypsum Compound and painting, or just
allowing maximum covering the surface with wallpapers. The plain surface of Board further
design flexibility permits the maximum flexibility to create any ceiling shapes, such
as stepped or vaulted, as well as to be applied in any areas.
No health hazard Even at high temperature or upon fire burning, Elephant Gypsum Board
and will not emit poisonous gas as it is formed up with Gypsum Mineral which
could prevent the known health hazard. Moreover, it could be re-used
Eco Friendliness
without any effect towards the environment.
Standard Fire resistant with heat and sound transmission Awarded ISOStandard 219-2524 5
control. Smooth, beautiful, yet highly functional and manufactured in accordance
f:j~a~~a:J.
'"'
'.
~ ....' .."
.~
.. .
..
.. .
Moist:m:;!;1 Extramoisture resistance with mixture of non Moisture absorption levelof less Ir
.
.""i~~.
JP!OIper
---
pi gkglutiifi\oUlstQmp~e.sseid
toepnanceits strength.Manufacti:l~ecl
f:dpr0vlde firE!resistance
+
Capability to reduce echo and absorb sound
- .'.-:.-::: tl
"
through the circle and square holes and capability according to NF
:.~:,':::
"""
. ..'..
. , ". bonded to back side with Glass Matt. Achieve EN20354 and ISO/DIS11654 d
. .."', ":.. fj
. ,. '.'"'.'... sound absorption rating of NRC 0.65-0.86.
." . tl
'..
..'. .. tJ
-----
Iwet area where humidity
5ceiling in water closet & kitchen.
is greatly present such
Designed as
Metric :- 1....
Metric
1200 x 2400 mm.
basefor ceramic tile. .""'''1''''
'.:
..
.~
.~
: ..
..
.
:l
1ainlyused in wall and ceiling wherever you wish
) increase sound absorption or achieve a desired
Metric :- Metric
1200 x 2400 mm.
ecorative finish. used in open plan area where
lere is a need to absorb sound people's voice so
Ht they do not disturb people in other area of
le room.
ca 1. The length of screw for fixing Gypsum Board to metal stud is equal to
the thickness of Gypsum Board plus 10 mm.
0 2. The thickness of the metal stud should be 5.5 mm.
3. The vertical metal stud should be set in the same direction.
4. If there is ajoint, the strength at the joint is lower.
5. If the width of the partition is above 15 m.,at every 15 m. interval an expansion joint
must be used in order to prevent cracking.
S 6. Always leave about 10 mm. space from the floor to prevent dampness.
7. In high humidity area,especially in the kitchen or bathroom, U-line stud which is laid
::s on the floor should be wrapped with plastic sheet before installation. The Moisbloc
is the most suitable for this purpose.
Cl)
For Ceiling
1. If the length of the concealed ceiling is above 15 m.,at every 15 m. interval a 10 mm.
~ space must be left in conjunction with the expansion joint to prevent cracking.
2. For the room requiring both Gypsum Board partition and ceiling, install the ceiling
@J before the partition. If the sound insulation is needed, install the partition before
the ceiling.
~ 3. For T-bar ceiling system, there should be enough ventilation above the ceiling
~ between the ceiling surface and the end of the straight bar should not exceed 5mm.
Ele~hant
Gypsum Board
Siam's "Elephant" Gypsum Board is trusted by not only all Thai customers but by
customers in over 35 countries to which it exports its products.