Name of Company: Name of Client: Job Tested: DISCHARGE DAMPER D’END/PIPE TO NOZZEL WELD JOINT (D1 & D2) Material: SA 240 TP 316, SA 312 TP 316 W.O. No.: LOYAL G39/17-18 Couplant: Oil Drawing No.:- LOYAL G39-DWG-1-01 REV-01 Job No.: LOYAL G39 M1A, M1B, M1C, M1D, M1E, M1F, M1G Surface of Examination / Condition: AS Welded Extent of Examination: 100% Method of Scanning & Overlap/Recording: Manual with 10% overlap UT Procedure No: N/A Reference Standard: ASME Sec-V Article -4. Acceptance Standard ASME Sec-VIII Div-I App-12. Equipment Make/ Model/ Sr. no.Cal.Due Modsonic/Einstein II DGS/E4613-0416/05-06-2018 Date: Testing Technique: Pulse echo reflection Stage of Examination : After Welding Technique. A-Scan. Place of Testing: Date of Testing : 06/01/2018 Identification & Location of Scanned Area : N/A System details with respect to Search Unit: Search unit Make Size Sr. no frequency Range used Angle Angle (60º) Modsonic 8 X 9 mm 187828396 4 MHz 200 mm Angle (45º) Modsonic 8 X 9 mm 300440689 4 MHz 125 mm Cable type/length Used: BNC to Small Lemo connector / 2 Mtr.
Search unit Ref. Reflector Amplitude Ref.Gain Scanning Gain
Angle (60º) ¼ t, ½ t,3/4 t. 80%,40%,20% 52 db 52 db Angle (45º) ¼ t, ½ t,3/4 t. 80%,40%,20% 55 db 55 db Calibration Data: Test Results: Observations: Free from objectionable flaw. (No Indication More Than 20% Of FSH Observed. No Backwall Loss Observed) Result: Job found satisfactory as per standard.
Test conducted by Witnessed/received by Inspection Agency/TPI