elevator, dumbwaiter, paternoster while others. determined from the size of the motor and the
Good start escalators consist of 4 major other components within the escalator system.
components. The lift elevator cab or plat form, This weight limit must be large enough to handle
the base or hoist way, the drive system and the daily utilization.
counterweight. The cab is moved vertically using
either hydraulic piston or a pulley system. The
weight of the cab is balanced by counterweights 3. Results and Discussion
so that the drive system uses minimal energy this
cannot be made too big and, therefore, have an This section present and discusses the results
effect on the structure of the building itself. obtained upon the program simulated by LOGIX
Possible constraints on the weight taken within PRO version 1.6. The results include the control
the elevator may be determined from the size of of the elevator floors and how to movie from
the motor unit and the other components within floor to next floor.
the elevator system. This weight limit must be
large enough to handle daily usage. The elevator A. Repeated Loop:
must fit within the given space requirements of
the building. It ought to be made large enough to When the press starts the elevator ready to movie
deal with the standard daily traffic also to move in this circuit use start and stop switch automatic
the necessary objects within home. It cannot be to energize the output b3.0, the output can
made too big and, therefore, affect the structure operation the program in repeated loop. As
of the building itself. Feasible restrictions on the shown in Figure1.
weight carried within the escalator may be
B. Floor Sense Subroutine Program: or letting it down. When the sensor sensed that
the human was at the correct floor, the door
Five different functions were required for the open/close function could run. The last function
elevator to work properly and after a function reset the system so the elevator could be called to
was completed the next could start. After a floor a different floor. Since there are five functions,
is sensed by the sensor, the elevator could be five different subroutines were put in place in the
called to another floor. With a floor called, the program. As shown in Figure 2.
hoist motor could operate, lifting the human up
IJEAM
www.ijeam.com
33
International Journal of Engineering, Applied and Management Sciences Paradigms, Vol. 42, Issue 01
Publishing Month: December 2016
An Indexed and Referred Journal
ISSN (Online): 2320-6608
www.ijeam.com
C. Call Floor Subroutine: button is pressed, its output coil turns on, sealing
the button. The output also deactivates the other
Next, the elevator could be called to a specific two floors rungs. With a floor called, the
floor when the call floor subroutine, operates. program returns to the main ladder diagram.
When the First, Second, or Third floor call
IJEAM
www.ijeam.com
34
International Journal of Engineering, Applied and Management Sciences Paradigms, Vol. 42, Issue 01
Publishing Month: December 2016
An Indexed and Referred Journal
ISSN (Online): 2320-6608
www.ijeam.com
E. Doors Subroutine done bit of the first timer activated the next
timer, which held the doors open for ten seconds.
Once the human reached the floor it was called The done bit from that timer activated the motor
to, the doors had to open, stay open for ten to close the doors. The master timer started its
seconds and then close. Three timers and a twenty seconds when the first timer started, when
master timer used in this subroutine when the the twenty second timer was done, it allowed a
floor that was called was sensed, a five second return from the doors subroutine. As shown in
timer was activated. While the timer was timing, Figure 5.
the motor would run, opening the doors. The
IJEAM
www.ijeam.com
35
International Journal of Engineering, Applied and Management Sciences Paradigms, Vol. 42, Issue 01
Publishing Month: December 2016
An Indexed and Referred Journal
ISSN (Online): 2320-6608
www.ijeam.com
References
[1] Elsevier Newnes,”programmable logic
controllers”, 4thEd, 2006.
[2] By John R. Hackworth Bolton W, and
Fredericck D. Hackworth,”Programmable
Logic Controllers: Methods and
Applications, Siemens Technical education
program”, 2003.
[3] Frazer, Roy,”Process Measurement and
Control Introduction Sensors,
Communication Adjustment, and Control”,
Prentice-Hall, Inc., 2001.
[4] Hong Kong IGDS,”Industrial Control and
programmable logic controller”, 2000.
[5] Jack Hugh,”Automating Manufacturing
system with PLCs”, 4.1thED 2002.
[6] Wikipedia, the free encyclopedia 3/12/2016
time 4:20pm.
[7] www.ep-wetherford.com/solution/proudcut
line.htm access 11/12/2016 time 11.15pm.