Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

akukon 2 2 4 1 - M 0 1 1 6.1.

2 0 0 6

Measurement of sound absorption in a reverberation room


According to the standards EN ISO 354:2003 and EN ISO 11654:1997

Client: Ovacon AB
Vånevik, Stora Viskär 572 93 OSKARSHAMN, Sweden
Eddie Ericsson

Sample: Manufacturer: Ovacon AB


Product: Sprefix S / Spraytec
Structure: 25 mm sprayed mineral wool
13 mm gypsum board (as a mechanical backing), mounting type B
concrete

Overall thickness: 38 mm

Date of measurement: 12.1.2006


Place of measurement: Finnish Broadcasting Company acoustics laboratory, reverberation room 5

Sample: Surface area: 12.48 m2

Conditions: Temperature: 19 ºC
Humidity: 44 %

Measurement results: Absorption class D according to the standard EN ISO 11654.


Weighted absorption coefficient αw according to EN ISO 11654: 0.55 (MH)

absorption coeff. α
f αS αS 1.20
Hz 1/3 octaves octaves
50 0.00 1.10
63 0.01 0.01
80 0.01 1.00
100 0.03
0.90
125 0.05 0.06
160 0.10
0.80
200 0.15
250 0.22 0.24 0.70
315 0.36
400 0.46 0.60
500 0.60 0.60
630 0.74 0.50
800 0.83
1000 0.91 0.90 0.40
1250 0.97
1600 1.02 0.30

2000 1.02 1.03


0.20
2500 1.03
3150 1.06 0.10
4000 1.08 1.09
5000 1.14 0.00
f, Hz 63 125 250 500 1000 2000 4000

akukon A k u k o n O y C o n s ultin g E n gin e e rs tel +3 5 8-9-5 6 1 7 1 7 0 Y -t u n n u s: 0 9 8 3 7 7 2 - 3


K o r n e tin ti e 4 A , FI- 0 0 3 8 0 H E L SIN KI fa x +3 5 8-9-5 6 1 7 1 7 1 1 first n a m e.l a st n a m e@a k u k o n.fi
akukon 2 2 4 1 - M 0 2 1 6.1.2 0 0 6

Measurement of sound absorption in a reverberation room


According to the standards EN ISO 354:2003 and EN ISO 11654:1997

Client: Ovacon AB
Vånevik, Stora Viskär 572 93 OSKARSHAMN, Sweden
Eddie Ericsson

Sample: Manufacturer: Ovacon AB


Product: Sprefix S / Spraytec
Structure: 40 mm sprayed mineral wool
13 mm gypsum board (as a mechanical backing), mounting type B
concrete

Overall thickness: 53 mm

Date of measurement: 12.1.2006


Place of measurement: Finnish Broadcasting Company acoustics laboratory, reverberation room 5

Sample: Surface area: 12.48 m2

Conditions: Temperature: 19 ºC
Humidity: 47 %

Measurement results: Absorption class A according to the standard EN ISO 11654.


Weighted absorption coefficient αw according to EN ISO 11654: 0.90 ()

absorption coeff. α
f αS αS 1.20
Hz 1/3 octaves octaves
50 0.01 1.10
63 0.03 0.02
80 0.03 1.00
100 0.06
0.90
125 0.16 0.16
160 0.26
0.80
200 0.42
250 0.61 0.62 0.70
315 0.81
400 0.95 0.60
500 1.06 1.05
630 1.15 0.50
800 1.17
1000 1.16 1.16 0.40
1250 1.16
1600 1.14 0.30

2000 1.11 1.12


0.20
2500 1.11
3150 1.10 0.10
4000 1.12 1.13
5000 1.17 0.00
f, Hz 63 125 250 500 1000 2000 4000

akukon A k u k o n O y C o n s ultin g E n gin e e rs tel +3 5 8-9-5 6 1 7 1 7 0 Y -t u n n u s: 0 9 8 3 7 7 2 - 3


K o r n e tin ti e 4 A , FI- 0 0 3 8 0 H E L SIN KI fa x +3 5 8-9-5 6 1 7 1 7 1 1 first n a m e.l a st n a m e@a k u k o n.fi
akukon 2 2 4 1 - M 0 3 1 6.1.2 0 0 6

Measurement of sound absorption in a reverberation room


According to the standards EN ISO 354:2003 and EN ISO 11654:1997

Client: Ovacon AB
Vånevik, Stora Viskär 572 93 OSKARSHAMN, Sweden
Eddie Ericsson

Sample: Manufacturer: Ovacon AB


Product: Sprefix S / Spraytec
Structure: 50 mm sprayed mineral wool
13 mm gypsum board (as a mechanical backing), mounting type B
concrete

Overall thickness: 63 mm

Date of measurement: 12.1.2006


Place of measurement: Finnish Broadcasting Company acoustics laboratory, reverberation room 5

Sample: Surface area: 12.48 m2

Conditions: Temperature: 19 ºC
Humidity: 51 %

Measurement results: Absorption class A according to the standard EN ISO 11654.


Weighted absorption coefficient αw according to EN ISO 11654: 1.00 ()

absorption coeff. α
f αS αS 1.20
Hz 1/3 octaves octaves
50 0.02 1.10
63 0.04 0.04
80 0.05 1.00
100 0.13
0.90
125 0.27 0.30
160 0.50
0.80
200 0.68
250 0.80 0.85 0.70
315 1.07
400 1.15 0.60
500 1.18 1.17
630 1.18 0.50
800 1.14
1000 1.11 1.12 0.40
1250 1.11
1600 1.08 0.30

2000 1.08 1.08


0.20
2500 1.07
3150 1.09 0.10
4000 1.08 1.08
5000 1.07 0.00
f, Hz 63 125 250 500 1000 2000 4000

akukon A k u k o n O y C o n s ultin g E n gin e e rs tel +3 5 8-9-5 6 1 7 1 7 0 Y -t u n n u s: 0 9 8 3 7 7 2 - 3


K o r n e tin ti e 4 A , FI- 0 0 3 8 0 H E L SIN KI fa x +3 5 8-9-5 6 1 7 1 7 1 1 first n a m e.l a st n a m e@a k u k o n.fi
akukon 2 2 4 1 - M 0 4 3 1.1.2 0 0 6

Measurement of sound absorption in an impedance tube


According to the standard SFS-EN ISO 10534-2

Client: Ovacon AB
Vånevik, Stora Viskär 572 93 OSKARSHAMN, Sweden
Eddie Ericsson

Sample: Manufacturer: Ovacon AB


Product: Spraytec A
Structure: <1 mm sprayed surface
28 mm sprayed glass wool

Overall thickness: ~30 mm

Date of measurement: 31.1.2006


Measurement system: Impedance tube, Brüel & Kjær Type 4206
Details on the measurement system are available in a separate report.
Number of samples: 3x ∅ 100 mm
3x ∅ 29 mm

Conditions: Temperature: 21 ºC
Humidity: 101,1 kPa
absorption coefficient mean value
Measurement results: 100 and 29 mm sample averages
deviation of individual results
absorption coeff. α
1.00
f α
Hz
50 0.00 0.90
63 0.00
80 0.00 0.80
100 0.00
125 0.01 0.70
160 0.05
200 0.08
250 0.11 0.60

315 0.17
400 0.29 0.50
500 0.42
630 0.59 0.40
800 0.73
1000 0.83
0.30
1250 0.83
1600 0.90
2000 0.90 0.20
2500 0.90
3150 0.90 0.10
4000 0.94
5000 0.96 0.00
f, Hz 63 125 250 500 1000 2000 4000

akukon A k u k o n O y C o n s ultin g E n gin e e rs t e l. + 3 5 8 - 9 - 5 6 1 7 1 7 0 B u sin e s s ID: 0 9 8 3 7 7 2 - 3


K o r n e tin ti e 4 A , FI- 0 0 3 8 0 H E L SIN KI fa x +3 5 8-9-5 6 1 7 1 7 1 1 first n a m e.l a st n a m e@a k u k o n.fi
akukon 2 2 4 1 - M 0 5 3 1.1.2 0 0 6

Measurement of sound absorption in an impedance tube


According to the standard SFS-EN ISO 10534-2

Client: Ovacon AB
Vånevik, Stora Viskär 572 93 OSKARSHAMN, Sweden
Eddie Ericsson

Sample: Manufacturer: Ovacon AB


Product: Spraytec A
Structure: <1 mm sprayed surface
40 mm sprayed glass wool

Overall thickness: ~40-45 mm

Date of measurement: 31.1.2006


Measurement system: Impedance tube, Brüel & Kjær Type 4206
Details on the measurement system are available in a separate report.
Number of samples: 3x ∅ 100 mm
3x ∅ 29 mm

Conditions: Temperature: 21 ºC
Humidity: 101,1 kPa
absorption coefficient mean value
Measurement results: 100 and 29 mm sample averages
deviation of individual results
absorption coeff. α
1.00
f α
Hz
50 0.00 0.90
63 0.00
80 0.00 0.80
100 0.00
125 0.07 0.70
160 0.15
200 0.20
0.60
250 0.30
315 0.38
400 0.56 0.50
500 0.69
630 0.74 0.40
800 0.72
1000 0.69
0.30
1250 0.67
1600 0.73
2000 0.75 0.20
2500 0.81
3150 0.85 0.10
4000 0.87
5000 0.93 0.00
f, Hz 63 125 250 500 1000 2000 4000

akukon A k u k o n O y C o n s ultin g E n gin e e rs t e l. + 3 5 8 - 9 - 5 6 1 7 1 7 0 B u sin e s s ID: 0 9 8 3 7 7 2 - 3


K o r n e tin ti e 4 A , FI- 0 0 3 8 0 H E L SIN KI fa x +3 5 8-9-5 6 1 7 1 7 1 1 first n a m e.l a st n a m e@a k u k o n.fi
akukon 2 2 4 1 - M 0 6 3 1.1.2 0 0 6

Measurement of sound absorption in an impedance tube


According to the standard SFS-EN ISO 10534-2

Client: Ovacon AB
Vånevik, Stora Viskär 572 93 OSKARSHAMN, Sweden
Eddie Ericsson

Sample: Manufacturer: Ovacon AB


Product: Sprefix S / Spraytec
Structure: 30 mm sprayed stone wool

Overall thickness: ~30 mm

Date of measurement: 31.1.2006


Measurement system: Impedance tube, Brüel & Kjær Type 4206
Details on the measurement system are available in a separate report.
Number of samples: 3x ∅ 100 mm
1x ∅ 29 mm

Conditions: Temperature: 21 ºC
Humidity: 101,1 kPa
absorption coefficient mean value
Measurement results: 100 and 29 mm sample averages
deviation of individual results
absorption coeff. α
1.00
f α
Hz
50 0.00 0.90
63 0.00
80 0.00 0.80
100 0.00
125 0.00 0.70
160 0.01
200 0.05
0.60
250 0.08
315 0.14
400 0.23 0.50
500 0.36
630 0.51 0.40
800 0.64
1000 0.73
0.30
1250 0.85
1600 0.82
2000 0.83 0.20
2500 0.87
3150 0.86 0.10
4000 0.90
5000 0.96 0.00
f, Hz 63 125 250 500 1000 2000 4000

akukon A k u k o n O y C o n s ultin g E n gin e e rs t e l. + 3 5 8 - 9 - 5 6 1 7 1 7 0 B u sin e s s ID: 0 9 8 3 7 7 2 - 3


K o r n e tin ti e 4 A , FI- 0 0 3 8 0 H E L SIN KI fa x +3 5 8-9-5 6 1 7 1 7 1 1 first n a m e.l a st n a m e@a k u k o n.fi
akukon 2 2 4 1 - M 0 7 3 1.1.2 0 0 6

Measurement of sound absorption in an impedance tube


According to the standard SFS-EN ISO 10534-2

Client: Ovacon AB
Vånevik, Stora Viskär 572 93 OSKARSHAMN, Sweden
Eddie Ericsson

Sample: Manufacturer: Ovacon AB


Product: Sprefix S / Spraytec
Structure: 40 mm sprayed stone wool

Overall thickness: ~40 mm

Date of measurement: 31.1.2006


Measurement system: Impedance tube, Brüel & Kjær Type 4206
Details on the measurement system are available in a separate report.
Number of samples: 3x ∅ 100 mm
4x ∅ 29 mm

Conditions: Temperature: 21 ºC
Humidity: 101,1 kPa
absorption coefficient mean value
Measurement results: 100 and 29 mm sample averages
deviation of individual results
absorption coeff. α
1.00
f α
Hz
50 0.00 0.90
63 0.00
80 0.00 0.80
100 0.00
125 0.03 0.70
160 0.11
200 0.16
0.60
250 0.23
315 0.35
400 0.47 0.50
500 0.58
630 0.66 0.40
800 0.71
1000 0.75
0.30
1250 0.75
1600 0.77
2000 0.80 0.20
2500 0.85
3150 0.86 0.10
4000 0.89
5000 0.94 0.00
f, Hz 63 125 250 500 1000 2000 4000

akukon A k u k o n O y C o n s ultin g E n gin e e rs t e l. + 3 5 8 - 9 - 5 6 1 7 1 7 0 B u sin e s s ID: 0 9 8 3 7 7 2 - 3


K o r n e tin ti e 4 A , FI- 0 0 3 8 0 H E L SIN KI fa x +3 5 8-9-5 6 1 7 1 7 1 1 first n a m e.l a st n a m e@a k u k o n.fi
akukon 2 2 4 1 - M 0 8 3 1.1.2 0 0 6

Measurement of sound absorption in an impedance tube


According to the standard SFS-EN ISO 10534-2

Client: Ovacon AB
Vånevik, Stora Viskär 572 93 OSKARSHAMN, Sweden
Eddie Ericsson

Sample: Manufacturer: Ovacon AB


Product: Sprefix S / Spraytec
Structure: 60 mm sprayed stone wool

Overall thickness: ~60 mm

Date of measurement: 31.1.2006


Measurement system: Impedance tube, Brüel & Kjær Type 4206
Details on the measurement system are available in a separate report.
Number of samples: 3x ∅ 100 mm
4x ∅ 29 mm

Conditions: Temperature: 21 ºC
Humidity: 101,1 kPa
absorption coefficient mean value
Measurement results: 100 and 29 mm sample averages
deviation of individual results
absorption coeff. α
1.00
f α
Hz
50 0.00 0.90
63 0.00
80 0.00 0.80
100 0.00
125 0.09 0.70
160 0.21
200 0.29
0.60
250 0.41
315 0.53
400 0.64 0.50
500 0.72
630 0.76 0.40
800 0.80
1000 0.81
0.30
1250 0.80
1600 0.87
2000 0.91 0.20
2500 0.91
3150 0.91 0.10
4000 0.93
5000 0.97 0.00
f, Hz 63 125 250 500 1000 2000 4000