Application suitability†
Pressure
Advantages Sterilization
solvents
Vacuum
Alkalies
Organic
Viscous
formulation classifications permeability
Sterile
fluids
fluids
Acids
Silicone
(platinum-cured) Excellent biocompatibility. USP Class V Extractables
No leachable additives, DOP, or plasticizers; N/R N/R N/R F G F E Exceeds Class VI Implant
96410-, 96510-series phthalate and latex-free; odorless and nontoxic, European Pharmacopoeia (EP 3.1.9) CO2: 20,132
Sterilize by EtO,
fungus-resistant. FDA 21 CFR 177.2600; FDA 21 CFR 210 H2: 6579
autoclave, or
No taste imparted to transported fluids. and 211; Exceeds 3A sanitary cGMPs; O2: 7961
Temperature range: gamma irradiation.
Weather, ozone, corona, and radiation resistant. REACH (non-DEHP) compliant N2: 2763
Minimal tendency to take a set. Static: –50 to 230°C (–58 to 446°F) RoHS compliant
Translucent, clear to light amber. Dynamic (pumping): –40 to 100°C ADCF compliant
(–40 to 212°F)
Silicone
(peroxide-cured) Excellent biocompatibility.
N/R N/R N/R F G F E USP Class VI
No additives, plasticizers or DOP; odorless
European Pharmacopoeia (EP 3.1.9)
96400-, 96406-series and nontoxic, fungus-resistant. CO2: 20,132
FDA 21 CFR 177.2600
No taste imparted to transported fluids. H2: 6579 Sterilize by EtO or
Exceeds 3A sanitary standards
Weather, ozone, corona, and O2: 7961 autoclave.
Temperature range: REACH (non-DEHP) compliant
radiation resistant. N2: 2763
Static: –50 to 230°C (–58 to 446°F) RoHS compliant
Minimal tendency to take a set.
Dynamic (pumping): –40 to 100°C ADCF compliant
Translucent, clear to light amber.
(–40 to 212°F)
BioPharm Plus
Silicone Similar to BioPharm Silicone, plus:
(platinum-cured) Longest life of any silicone pump tubing. N/R N/R N/R F G F E USP Class VI
Lower spallation than regular silicone. European Pharmacopoeia (EP 3.1.9) CO2: 25,147
96440-, 96441-series Sterilize by EtO,
Enhanced pressure capability. FDA 21 CFR 177.2600 H2: —
autoclave, or
Fungus-resistant. Exceeds 3A sanitary standards O2: 4715
gamma irradiation.
Nontoxic, no leachable plasticizers. Temperature range: REACH (non-DEHP) compliant N2: 2284
Lower gas permeability than other silicones. Static: –60 to 232°C (–75 to 450°F) RoHS compliant
Translucent, clear to light amber. Dynamic (pumping): –40 to 100°C
(–40 to 212°F)
Biocompatible.
Puri-Flex™ Heat sealable and weldable.
Long pump life when compared to silicone G G N/R G G E E USP Class VI
Sterilize by EtO,
96419-series or other TPE tubings. FDA 21 CFR 177.2600 and CO2: 1200
autoclave up to
Low spallation when compared to silicone 177.1810 H2: —
135°C (275°F),
or some other TPE tubings. REACH (non-DEHP) compliant O2: 200
Temperature range: gamma irradiation
Very low protein binding. RoHS compliant N2: 80
Static: –50 to 135°C (–58 to 275°F) up to 4.5 Mrad.
Cost effective. ADCF compliant
No halogens or phthalates. Dynamic (pumping): –30 to 100°C
Translucent, clear to light white. (–22 to 212°F)
C-Flex®
Physical properties similar to silicone G G N/R F G F E
USP Class VI
06424-series with chemical compatibility of Tygon®. CO2: —
European Pharmacopoeia (EP 3.2.9) Sterilize by EtO,
Inexpensive. H2: —
REACH (non-DEHP) compliant autoclave, or
Biocompatible. O2: 150
Temperature range: RoHS compliant gamma irradiation.
Heat sealable and weldable. N2: —
Static: –45 to 121°C (–50 to 250°F) ADCF compliant
Opaque, white.
Dynamic (pumping): –40 to 100°C
(–40 to 212°F)
C-Flex® ULTRA
Physical properties similar to silicone G G N/R F G F E Sterilize by gamma
with chemical compatibility of Tygon®. USP Class VI
06434-series CO2: 2.1 irradiation or one
Biocompatible. European Pharmacopoeia (EP 3.2.9)
H2: — cycle of autoclave
Heat sealable and weldable. REACH (non-DEHP) compliant
O2: 1.1 at 121°C (250°F),
Longer pump life and lower spallation Temperature range: RoHS compliant
N2: 3.4 1 bar (15 psi) for
than C-Flex. Static: –45 to 121°C (–50 to 250°F) ADCF compliant
30 minutes.
Translucent. Dynamic (pumping): –40 to 100°C
(–40 to 212°F)
†E = Excellent, G = Good, F = Fair, P = Poor, N/R = not recommended
Pressure
solvents
Advantages Sterilization
Vacuum
Alkalies
Organic
Viscous
formulation classifications permeability
Sterile
fluids
fluids
Acids
Great for tissue and cell
PharMed® BPT work—nontoxic and nonhemolytic.
Long service life (up to 10,000 hrs); G G N/R G G E E USP Class VI
06508-series reduces tubing costs and pump downtime. European Pharmacopoeia (EP 3.2.9) CO2: 1200 Sterilize by EtO,
Opaque to UV and visible light to protect FDA 21 CFR 177.2600 H2: — autoclave, or
light-sensitive fluids. NSF-51 O2: 200 gamma irradiation
Low gas permeability. Temperature range: REACH (non-DEHP) compliant N2: 80 up to 2.5 Mrad.
High-pressure 10.3 bar (150 psi) version Static: –51 to 132°C (–60 to 270°F) RoHS compliant
available. Dynamic (pumping): –20 to 100°C
Opaque, beige (–4 to 212°F)
GORE® STA-PURE®
pump tubing N/R N/R N/R E G G E USP Class VI
Unique composite structure adds strength and
Series PCS (96211-) USP <87>
flex durability. Sterilize by
USP Physicochemical Tests
Greater security against rupture up to 100 psig*. — autoclave or SIP
Compliant with restricted
Consistent flow rate over long duration of use. (steam in place).
substances per REACH and RoHS
Withstands rigors of CIP/SIP processing. Temperature range: No raw materials of animal origin
Contact Cole-Parmer
GORE® STA-PURE®
pump tubing E E E E G G E USP Class VI
Unique composite structure adds strength and
Series PFL (96212-) USP <87>
flex durability. Sterilize by
USP Physicochemical Tests
Greater chemical resistance than Series PCS. — autoclave or SIP
Compliant with restricted
Stable flow rates achievable to 60 psig*. (steam in place).
substances per REACH and RoHS
Withstands rigors of CIP/SIP processing. Temperature range: No raw materials of animal origin
Contact Cole-Parmer
Chem-Durance® Bio
Excellent chemical resistance. E E G E E E E
Excellent life and durability under pressure.
06442-series USP Class VI CO2: 745
Low spallation. Sterilize by EtO,
FDA 21 CFR 177.2600 H2: —
Plasticizer-free inner liner. autoclave or
REACH (non-DEHP) compliant O2: 200
High dielectric constant. Temperature range: gamma irradiation.
RoHS Compliant N2: 80
Excellent biocompatibility. Static: –60 to 74°C (–71 to 165°F)
Opaque, beige. Dynamic (pumping): 0 to 40°C
(32 to 104°F)
Pressure
solvents
Vacuum
Advantages Sterilization
Alkalies
Organic
Viscous
formulation classifications permeability
Sterile
fluids
fluids
Acids
Longest life of all Tygon® peristaltic tubing.
Tygon® E-LFL Clear for easy flow monitoring. USP Class VI
G G N/R G G E G
Broad chemical resistance. European Pharmacopia (EP 3.2.9)
CO2: 563
06440-series Nonaging, nonoxidizing. FDA 21 CFR 175.300
H2: —
Sterilize by EtO or
Low gas permeability. EU Food autoclave.
Temperature range: O2: 124
Smooth bore. REACH (non-DEHP) compliant
Static: –46 to 74°C (–51 to 165°F) N2: 67
Good for viscous fluids. RoHS compliant
High dielectric constant. Dynamic (pumping): 0 to 40°C ADCF compliant
Transparent, clear. (32 to 104°F)
Viton®