Download as pdf or txt
Download as pdf or txt
You are on page 1of 32

SURGE

PROTECTION
DEVICES
1
SURGE PROTECTION DEVICES

DIN Rail, combined Type 1&2 / Class I & II SPD with MOV and
SPD Type 1 for 1.5 kV Protection Level with MOV & CDGG Technology CDGG technology for use in 230 / 400 Vac power supply
system at boundaries from LPZ 0A-2

Features:
- MOV and CDGG technology
- Non-follow current
- Combined disconnection device
- High discharge capacity
- Capable of protecting terminal equipment
- Visual and remote status indication
- Multi functional terminals for connecting
conductors and busbars
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & CDGG With changeover contact SP1W260-25/1NR
Nominal Voltage (UN) 230/400 Vac Without changeover contact SP1W260-25/1N
Max. continuous operating voltage (UC) 260 Vac
Nominal discharge current (8/20 μs) (In) 25 kA
Lightning impulse current (10/350 μs) (limp) 25 kA
Voltage protection level (UP) 1.5 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status / fault indication Green / red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, combined Type 1&2 / Class I&II with CDGG


SPD Type 1 for 1.0 kV Protection Level technology for use in 230/400 Vac power supply system at
boundaries from LPZ 0A-2, and specially designed for
installation between N and PE

Features:
- CDGG technology
- High discharge capacity
- Capable of protecting terminal equipment
- Visual status indication
- Multifunctional terminals for connecting
conductors and busbars
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology CDGG Without changeover contact SP1W260-100/1P
Nominal Voltage (UN) 230/400 Vac
Max. continuous operating voltage (UC) 260 Vac
Nominal discharge current (8/20 μs) (In) 100 kA
Lightning impulse current (10/350 μs) (limp) 100 kA
Voltage protection level (UP) 1.0 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
2
WWW.CONNECTWELL.COM

DIN Rail, combined Type 1&2/Class I&II with CDGG


SPD Type 1 for 2.0 kV Protection Level technology for use in TN-S, T T power supply network
system at boundaries LPZ from 0A-2

Features:
- CDGG technology
- High discharge capacity
- Capable of protecting terminal equipment
- Multifunctional terminals for connecting
conductors and bus bars
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology CDGG Without changeover contact SP1W260-25/4P
Nominal Voltage (UN) 230/400 Vac
Max. continuous operating voltage (UC) 260 Vac (L-N), 260 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 25 kA (L-N), 100 kA (N-PE)
Lightning impulse current (10/350 μs) (limp) 25 kA (L-N), 100 kA (N-PE)
Voltage protection level (UP) 2.0 kV
Enclosure dimensions (HxWxD) 90 mm x 90 mm x 77 mm
Operating status/fault indication light on/off

DIN Rail, combined Type 1& 2 /Class I&II with MOV and CDGG
SPD Type 1 for 2.0 kV Protection Level with MOV & CDGG Technology technology for use in different power supply system at
boundaries from LPZ 0A-2

Features:
- MOV and CDGG technology
- Non-follow current
- Combined disconnection device
- High discharge capacity
- Capable of protecting terminal equipment
- Visual and remote status indication
- Multifunctional terminals for connecting
conductors and busbars
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & CDGG With changeover contact SP1W440-25/1NR
Nominal Voltage (UN) 400 / 690 Vac Without changeover contact SP1W440-25/1N
Max. continuous operating voltage (UC) 440 Vac
Nominal discharge current (8/20 μs) (In) 25 kA
Lightning impulse current (10/350 μs) (limp) 25 kA
Voltage protection level (UP) 2.0 kV
Enclosure dimensions (HxWxD) 150 mm x 36 mm x 72 mm
Operating status/fault indication Black / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A
3
SURGE PROTECTION DEVICES

DIN Rail, combined Type 1&2 / Class I & II with MOV and CDGG
SPD Type 1 for 3.5 kV Protection Level with MOV & CDGG Technology technology for use in different power supply system at
boundaries from LPZ 0A-2

Features:
- MOV and CDGG technology
- Non-follow current
- Combined disconnection device
- High discharge capacity
- Capable of protecting terminal equipment
- Visual and remote status indication
- Multi functional terminals for connecting
conductors and busbars
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & CDGG With changeover contact SP1W760-25/1NR
Nominal Voltage (UN) 400 / 690 Vac (IT 690 Vac) Without changeover contact SP1W760-25/1N
Max. continuous operating voltage (UC) 760 Vac
Nominal discharge current (8/20 μs) (In) 25 kA
Lightning impulse current (10/350 μs) (limp) 25 kA
Voltage protection level (UP) 3.5 kV
Enclosure dimensions (HxWxD) 150 mm x 36 mm x 72 mm
Operating status / fault indication Black / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, combined Type 1&2 /Class I&II with MOV and CDGG
SPD Type 1 for 2.4 kV Protection Level with MOV & CDGG Technology technology for use in different power supply system at
boundaries from LPZ 0A-2

Features:
- MOV and CDGG technology
- Non-follow current
- Combined disconnection device
- High discharge capacity
- Capable of protecting terminal equipment
- Visual and remote status indication
- Multi functional terminals for connecting
conductors and busbars
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & CDGG With changeover contact SP1W600-25/1NR
Max. PV voltage (UCPV) 600 V Without changeover contact SP1W600-25/1N
Nominal discharge current (8/20 μs) (In) 25 kA
Lightning impulse current (10/350 μs) (limp) 25 kA
Voltage protection level (UP) 2.4 kV
Voltage protection level for 5kA (UP) 2.0 kV
Enclosure dimensions (HxWxD) 150 mm x 36 mm x 72 mm
Operating status/fault indication Black / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A
4
WWW.CONNECTWELL.COM

DIN Rail, combined Type 1&2 /Class I&II with MOV and CDGG
SPD Type 1 for 4.0 kV Protection Level with MOV & CDGG Technology technology for use in different power supply system at
boundaries from LPZ 0A-2

Features:
- MOV and CDGG technology
- Non-follow current
- Combined disconnection device
- High discharge capacity
- Capable of protecting terminal equipment
- Visual and remote status indication
- Multi functional terminals for connecting
conductors and busbars
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & CDGG With changeover contact SP1W1000-25/1NR
Max. PV voltage (UCPV) 1000 V Without changeover contact SP1W1000-25/1N
Nominal discharge current (8/20 μs) (In) 25 kA
Lightning impulse current (10/350 μs) (limp) 25 kA
Voltage protection level (UP) 4.0 kV
Voltage protection level for 5kA (UP) 2.5 kV
Enclosure dimensions (HxWxD) 150 mm × 36 mm × 72 mm
Operating status/fault indication Black / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, spark gap unit for isolating the harmonic wave
Isolated Module with 150 kA Nominal Discharge Current interface

Features:
- CDGG technology
- High discharge capacity
- Multifunctional terminals for connecting
conductors and busbars
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology CDGG Without changeover contact SP1W2000-100/2PS
Turn-on Voltage 2.0 kV
Nominal discharge current (8/20 μs) (In) 150 kA
Lightning impulse current (10/350 μs) (limp) 105 kA
Enclosure dimensions (HxWxD) 150 mm x 36 mm x 72 mm
5
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with high duty MOVs for use in a.c.
SPD Type 2 for 1.6 kV Protection Level with 80 kA Max Discharge Current system at boundaries from LPZ 0B-1 and higher

Features:
- Uniform current flow technology of MOV
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Capable of protecting terminal equipment
- Multifunctional terminals for
connecting conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2W385-80/2PR
Nominal Voltage (UN) 230/400 Vac Without changeover contact SP2W385-80/2P
Max. continuous operating voltage (UC) 385 Vac (L-N), 260 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 40 kA
Max. discharge current (8/20 μs) (Imax) 80 kA
Voltage protection level (UP) 1.6 kV (L-N),1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with high duty MOVs for use in
SPD Type 2 for 1.8 kV Protection Level with 100 kA Max Discharge Current a.c. system at boundaries from LPZ 0B-1 and higher

Features:
- Uniform current flow technology of MOV
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Capable of protecting terminal equipment
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2W385-100/2PR
Max. continuous operating voltage (UC) 385 Vac (L-N), 260 Vac (N-PE) Without changeover contact SP2W385-100/2P
Nominal discharge current (8/20 μs) (In) 50 kA
Max. discharge current (8/20 μs) (Imax) 100 kA
Voltage protection level (UP) 1.8 kV (L-N),1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A
6
WWW.CONNECTWELL.COM

DIN Rail, Type 2 /Class II SPD with high duty MOVs for use in
SPD Type 2 for 1.8 kV Protection Level with 120 kA Max Discharge Current a.c. system at boundaries from LPZ 0B-1 and higher

Features:
- Uniform current flow technology of MOV
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Capable of protecting terminal equipment
- Multifunctional terminals for
connecting conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2W385-120/2PR
Nominal Voltage (UN) 230/400 Vac Without changeover contact SP2W385-120/2P
Max. continuous operating voltage (UC) 385 Vac (L-N), 260 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 60 kA
Max. discharge current (8/20 μs) (Imax) 120 kA
Voltage protection level (UP) 1.8 kV (L-N),1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with high duty MOVs for use in
SPD Type 2 for 1.6 kV Protection Level with 80 kA Max Discharge Current a.c.
system at boundaries from LPZ 0B-1 and higher

Features:
- Uniform current flow technology of MOV
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Capable of protecting terminal equipment
- Multifunctional terminals for
connecting conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2W385-80/4PR
Nominal Voltage (UN) 230/400 Vac Without changeover contact SP2W385-80/4P
Max. continuous operating voltage (UC) 385 Vac (L-N), 260 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 40 kA
Max. discharge current (8/20 μs) (Imax) 80 kA
Voltage protection level (UP) 1.6 kV (L-N),1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 144 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A
7
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with high duty MOVs for use in a.c.
SPD Type 2 for 1.8 kV Protection Level with 100 kA Max Discharge Current system at boundaries from LPZ 0B-1 and higher

Features:
- Uniform current flow technology of MOV
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Capable of protecting terminal equipment
- Multifunctional terminals for
connecting conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2W385-100/4PR
Nominal Voltage (UN) 230/400 Vac Without changeover contact SP2W385-100/4P
Max. continuous operating voltage (UC) 385 Vac (L-N), 260 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 50 kA
Max. discharge current (8/20 μs) (Imax) 100 kA
Voltage protection level (UP) 1.8 kV (L-N),1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 144 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with high duty MOVs for use in
SPD Type 2 for 1.8 kV Protection Level with 120 kA Max Discharge Current a.c.
system at boundaries from LPZ 0B-1 and higher

Features:
- Uniform current flow technology of MOV
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Capable of protecting terminal equipment
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2W385-120/4PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2W385-120/4P
Max. continuous operating voltage (UC) 385 Vac (L-N), 260 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 60 kA
Max. discharge current (8/20 μs) (Imax) 120 kA
Voltage protection level (UP) 1.8 kV (L-N),1.5kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 144 mm x 66 mm
Operating status/fault indication Green / red
Type of remote signaling contact Changeover contact

Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A


8
WWW.CONNECTWELL.COM

DIN Rail, Type 2 / Class II multi-purpose single-pole SPD with


SPD Type 2 for 0.6 kV Protection Level anti-vibration pluggable module for use in a.c. or d.c. system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M60-40/1NR
Nominal Voltage (UN) 48 Vac Without changeover contact SP2M60-40/1N
Max. continuous operating voltage (UC) 60 Vac / 75 Vdc
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 0.6 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, Type 2 / Class II multi-purpose single-pole SPD with


SPD Type 2 for 1.0 kV Protection Level anti-vibration pluggable module for use in a.c. or d.c. system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M150-40/1NR
Nominal Voltage (UN) 120 / 240 V Without changeover contact SP2M150-40/1N
Max. continuous operating voltage (UC) 150 Vac / 180 Vdc
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.0 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A
9
SURGE PROTECTION DEVICES

DIN Rail, Type 2 / Class II multi-purpose single-pole SPD with


SPD Type 2 for 1.8 kV Protection Level anti-vibration pluggable module for use in a.c. or d.c. system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due
to module releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M275-40/1NR
Nominal Voltage (UN) 230/400 Vac Without changeover contact SP2M275-40/1N
Max. continuous operating voltage (UC) 275 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.3 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, Type 2 / Class II multi-purpose single-pole SPD with


SPD Type 2 for 1.5 kV Protection Level anti-vibration pluggable module for use in a.c. or d.c. system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due
to module releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M320-40/1NR
Nominal Voltage (UN) 230/400 Vac Without changeover contact SP2M320-40/1N
Max. continuous operating voltage (UC) 320 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.5 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A
10
WWW.CONNECTWELL.COM

DIN Rail, Type 2 / Class II multi-purpose single-pole SPD with


SPD Type 2 for 1.3 kV Protection Level anti-vibration pluggable module for use in a.c. or d.c. system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M385-40/1NR
Nominal Voltage (UN) 230/400 Vac Without changeover contact SP2M385-40/1N
Max. continuous operating voltage (UC) 385 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.8 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, Type 2 / Class II multi-purpose single-pole SPD with


SPD Type 2 for 2.2 kV Protection Level anti-vibration pluggable module for use in a.c. or d.c. system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M440-40/1NR
Nominal Voltage (UN) 230/400 Vac Without changeover contact SP2M440-40/1N
Max. continuous operating voltage (UC) 440 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 2.2 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A
11
SURGE PROTECTION DEVICES

DIN Rail, Type 2 / Class II multi-purpose single-pole SPD with


SPD Type 2 for 3.0 kV Protection Level anti-vibration pluggable module for use in a.c. or d.c. system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M760-25/1NR
Nominal Voltage (UN) 400 / 690 Vac Without changeover contact SP2M760-25/1N
Max. continuous operating voltage (UC) 760 Vac
Nominal discharge current (8/20 μs) (In) 15 kA
Max. discharge current (8/20 μs) (Imax) 25 kA
Voltage protection level (UP) 3.0 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, Type 2 /Class II multi-purpose single-pole SPD with


SPD Type 2 for 1.5 kV Protection Level with GDT Technology anti-vibration pluggable module for use in 230/400 Vac system
at boundaries from LPZ 0B-1 and higher, and especially
designed for installation between N and PE

Features:
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due
to module releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology GDT With changeover contact SP2M255-40/1PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M255-40/1P
Max. continuous operating voltage (UC) 255 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.5 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
12
WWW.CONNECTWELL.COM

DIN Rail, spark gap unit for isolating the harmonic wave
Isolated Module with 60 kA Nominal discharge current interface

Features:
- CDGG technology
- High discharge capacity
- Multifunctional terminals for connecting
conductors and busbars
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology CDGG Without changeover contact SP2M2000-60/2PS
Turn-on Voltage 2.0 kV
Nominal discharge current (8/20 μs) (In) 60 kA
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.3 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac single phase TT and TN system
at boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M275-40/2PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M275-40/2P
Max. continuous operating voltage (UC) 275 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.3 kV (L-N), 1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.0 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A
13
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.5 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac single phase TT and TN system
at boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M320-40/2PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M320-40/2P
Max. continuous operating voltage (UC) 320 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.5 kV (L-N), 1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.8 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac single phase TT and TN system
at boundaries from LPZ 0B-1 and higher

Features:
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due
to module releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M385-40/2PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M385-40/2P
Max. continuous operating voltage (UC) 385 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.8 kV (L-N), 1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.3 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A
14
WWW.CONNECTWELL.COM

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.8 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac single phase TT and TN system
at boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M320-60/2PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M320-60/2P
Max. continuous operating voltage (UC) 320 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 30 kA
Max. discharge current (8/20 μs) (Imax) 60 kA
Voltage protection level (UP) 1.8 kV (L-N), 1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 125 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 2.0 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac single phase TT and TN system
at boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M385-60/2PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M385-60/2P
Max. continuous operating voltage (UC) 385 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 30 kA
Max. discharge current (8/20 μs) (Imax) 60 kA
Voltage protection level (UP) 2.0 kV (L-N), 1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.3 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
15
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 0.6 kV Protection Level module for use in a.c. single phase TN system at boundaries
from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M60-40/2NR
Nominal Voltage (UN) 48 Vdc Without changeover contact SP2M60-40/2N
Max. continuous operating voltage (UC) 60 Vac / 75 Vdc
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 0.6 kV
Voltage protection level for 5kA (UP) 0.5 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.0 kV Protection Level module for use in a.c. single phase TN system at boundaries
from LPZ 0B-1 and higher
Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M150-40/2NR
Nominal Voltage (UN) 120 / 240 Vac Without changeover contact SP2M150-40/2N
Max. continuous operating voltage (UC) 150 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.0 kV
Voltage protection level for 5kA (UP) 0.6 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
16
WWW.CONNECTWELL.COM

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.3 kV Protection Level module for use in 230/400 Vac single phase TT and TN system
at boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M275-40/2NR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M275-40/2N
Max. continuous operating voltage (UC) 275 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.3 kV
Voltage protection level for 5kA (UP) 1.0 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.8 kV Protection Level module for use in a.c. single phase TN system at boundaries
from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M385-40/2NR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M385-40/2N
Max. continuous operating voltage (UC) 385 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.8 kV
Voltage protection level for 5kA (UP) 1.3 kV
Enclosure dimensions (HxWxD) 90 mm x 36 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
17
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.3 kV Protection Level module for use in a.c. TNC or IT system at boundaries from LPZ
0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M275-40/3NR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M275-40/3N
Max. continuous operating voltage (UC) 275 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.3 kV
Voltage protection level for 5kA (UP) 1.0 kV
Enclosure dimensions (HxWxD) 90 mm x 54 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.8 kV Protection Level module for use in a.c. TNC or IT system at boundaries from LPZ
0B-1 and higher
Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M385-40/3NR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M385-40/3N
Max. continuous operating voltage (UC) 385 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.8 kV
Voltage protection level for 5kA (UP) 1.3 kV
Enclosure dimensions (HxWxD) 90 mm x 54 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
18
WWW.CONNECTWELL.COM

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 2.2 kV Protection Level module for use in a.c. TNC or IT system at boundaries from LPZ
0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M440-40/3NR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M440-40/3N
Max. continuous operating voltage (UC) 440 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 2.2 kV
Voltage protection level for 5kA (UP) 1.6 kV
Enclosure dimensions (HxWxD) 90 mm x 54 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 3.0 kV Protection Level module for use in a.c. TNC or IT system at boundaries from LPZ
0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M760-25/3NR
Nominal Voltage (UN) 400 / 690 Vac Without changeover contact SP2M760-25/3N
Max. continuous operating voltage (UC) 760 Vac
Nominal discharge current (8/20 μs) (In) 15 kA
Max. discharge current (8/20 μs) (Imax) 25 kA
Voltage protection level (UP) 3.0 kV
Voltage protection level for 5kA (UP) 2.5 kV
Enclosure dimensions (HxWxD) 90 mm x 54 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
19
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.3 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac TT and TN-S system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M275-40/4PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M275-40/4P
Max. continuous operating voltage (UC) 275 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.3 kV (L-N), 1.5kV (N-PE)
Voltage protection level for 5kA (UP) 1.0 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.5 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac TT and TN-S system at
boundaries from LPZ 0B-1 and higher
Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M320-40/4PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M320-40/4P
Max. continuous operating voltage (UC) 320 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.5 kV (L-N), 1.5kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
20
WWW.CONNECTWELL.COM

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.8 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac TT and TN-S system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M385-40/4PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M385-40/4P
Max. continuous operating voltage (UC) 385 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.8 kV (L-N), 1.5kV (N-PE)
Voltage protection level for 5kA (UP) 1.3 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 2.2 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac TT and TN-S system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M440-40/4PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M440-40/4P
Max. continuous operating voltage (UC) 440 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 2.2 kV (L-N), 1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.6 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
21
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.8 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac TT and TN-S system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M320-60/4PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M320-60/4P
Max. continuous operating voltage (UC) 320 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.8 kV (L-N), 1.5kV (N-PE)
Voltage protection level for 5kA (UP) 1.2 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 2.0 kV Protection Level with MOV & GDT Technology module for use in 230/400 Vac TT and TN-S system at
boundaries from LPZ 0B-1 and higher
Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & GDT With changeover contact SP2M385-60/4PR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M385-60/4P
Max. continuous operating voltage (UC) 385 Vac (L-N), 255 Vac (N-PE)
Nominal discharge current (8/20 μs) (In) 30 kA
Max. discharge current (8/20 μs) (Imax) 60 kA
Voltage protection level (UP) 2.0 kV (L-N), 1.5 kV (N-PE)
Voltage protection level for 5kA (UP) 1.3 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
22
WWW.CONNECTWELL.COM

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.3 kV Protection Level module for use in 230/400 Vac TN-S system at boundaries from
LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M275-40/4NR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M275-40/4N
Max. continuous operating voltage (UC) 275 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.3 kV
Voltage protection level for 5kA (UP) 1.0 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 1.3 kV Protection Level module for use in 230/400 Vac TN-S system at boundaries
from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M385-40/4NR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M385-40/4N
Max. continuous operating voltage (UC) 385 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.8 kV
Voltage protection level for 5kA (UP) 1.3 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
23
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD Type 2 for 2.2 kV Protection Level module for use in 230/400 Vac TN-S system at boundaries from
LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SP2M440-40/4NR
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M440-40/4N
Max. continuous operating voltage (UC) 440 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 2.2 kV
Voltage protection level for 5kA (UP) 1.6 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD with isolated module with 3.2 kV Protection Level module for use in TNC system at boundaries from LPZ 0B-1 and
higher, and especially designed isolated module to prevent the
harmonic wave interference
Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & CDGG With changeover contact SP2M385-40/5PRS
Nominal Voltage (UN) 230 / 400 Vac Without changeover contact SP2M385-40/5PR
Max. continuous operating voltage (UC) 385 Vac
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 3.2 kV
Voltage protection level for 5kA (UP) 1.5 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
24
WWW.CONNECTWELL.COM

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


SPD with isolated module with 4.0 kV Protection Level module for use in TNC system at boundaries from LPZ 0B-1 and
higher, and especially designed isolated module to prevent the
harmonic wave interference
Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV & CDGG With changeover contact SP2M760-25/5PRS
Nominal Voltage (UN) 400 / 690 Vac Without changeover contact SP2M760-25/5PR
Max. continuous operating voltage (UC) 760 Vac
Nominal discharge current (8/20 μs) (In) 15 kA
Max. discharge current (8/20 μs) (Imax) 25 kA
Voltage protection level (UP) 4.0 kV
Voltage protection level for 5kA (UP) 3.0 kV
Enclosure dimensions (HxWxD) 90 mm x 72 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


PV DC SPD Type 2 with 1.75 kV Protection Level module for use in PV d.c. system at boundaries from LPZ 0B-1
and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M500-40/1NR
Max. continuous operating d.c. voltage (UCPV) 500 V
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.75 kV
Voltage protection level for 5kA (UP) 1.4 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
25
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


PV DC SPD Type 2 with 2.0 kV Protection Level module for use in PV d.c. system at boundaries from LPZ 0B-1
and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M600-40/1NR
Max. continuous operating d.c. voltage (UCPV) 600 V
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 2.0 kV
Voltage protection level for 5kA (UP) 1.5 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


PV DC SPD Type 2 with 2.5 kV Protection Level module for use in PV d.c. system at boundaries from LPZ 0B-1
and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M750-25/1NR
Max. continuous operating d.c. voltage (UCPV) 750 V
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 25 kA
Voltage protection level (UP) 2.5 kV
Voltage protection level for 5kA (UP) 1.9 kV
Enclosure dimensions (HxWxD) 90 mm x 18 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
26
WWW.CONNECTWELL.COM

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


PV DC SPD Type 2 with 1.2 kV Protection Level module for use in PV d.c. system at boundaries from LPZ 0B-1
and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M200-40/3PR
Max. continuous operating d.c. voltage (UCPV) 200 V Without changeover contact SPV2M200-40/3P
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 25 kA
Voltage protection level (UP) 1.2 kV
Voltage protection level for 5kA (UP) 0.7 kV
Enclosure dimensions (HxWxD) 90 mm x 54 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


PV DC SPD Type 2 with 3.5 kV Protection Level module for use in PV d.c. system at boundaries from LPZ 0B-1
and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M1000-40/3PR
Max. continuous operating d.c. voltage (UCPV) 1000 V Without changeover contact SPV2M1000-40/3P
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 3.5 kV
Voltage protection level for 5kA (UP) 2.8 kV
Enclosure dimensions (HxWxD) 90 mm x 54 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
27
SURGE PROTECTION DEVICES

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


PV DC SPD Type 2 with 4.0 kV Protection Level module for use in PV d.c. system at boundaries from LPZ 0B-1
and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M1200-40/3PR
Max. continuous operating d.c. voltage (UCPV) 1200 V Without changeover contact SPV2M1200-40/3P
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 4.0 kV
Voltage protection level for 5kA (UP) 3.0 kV
Enclosure dimensions (HxWxD) 90 mm x 54 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


PV DC SPD Type 2 with 1.75 kV Protection Level module for use in PV d.c. system at boundaries from LPZ 0B-1
and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M600-40/3PR
Max. continuous operating d.c. voltage (UCPV) 600 V Without changeover contact SPV2M600-40/3P
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 2.8 kV
Voltage protection level for 5kA (UP) 2.0 kV
Enclosure dimensions (HxWxD) 90 mm x 54 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
28
WWW.CONNECTWELL.COM

DIN Rail, Type 2 /Class II SPD with anti-vibration pluggable


PV DC SPD Type 2 with 5.0 kV Protection Level module for use in PV d.c. system at boundaries from LPZ 0B-1
and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- Consisting of a base part and pluggable modules
- Easy replacing and anti-vibration due to module
releasing and locking system
- Multifunctional terminals for connecting
conductors and busbars
- Visual and remote status indication
- DIN Rail installation

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M1500-25/3PR
Max. continuous operating d.c. voltage (UCPV) 1500 V Without changeover contact SPV2M1500-25/3P
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 25 kA
Voltage protection level (UP) 5.0 kV
Voltage protection level for 5kA (UP) 3.8 kV
Enclosure dimensions (HxWxD) 90 mm x 54 mm x 66 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

PCB on board, Type 2 /Class II multi-purpose single-pole SPD


PV DC SPD Type 2 with 1.9 kV Protection Level withanti-vibration pluggable module for use in PV DC system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- PCB on board with slim size
- Easy replacing and anti-vibration due to
module releasing and locking system
- Visual and remote status indication

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M500-40/1N
Max. continuous operating d.c. voltage (UCPV) 500 V
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 1.9 kV
Voltage protection level for 5kA (UP) 1.4 kV
Enclosure dimensions (HxWxD) 52 mm x 18 mm x 45 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
29
SURGE PROTECTION DEVICES

PCB on board, Type 2 /Class II multi-purpose single-pole SPD


PV DC SPD Type 2 with 2.1 kV Protection Level withanti-vibration pluggable module for use in PV DC system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- PCB on board with slim size
- Easy replacing and anti-vibration due to
module releasing and locking system
- Visual and remote status indication

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M600-40/1N
Max. continuous operating d.c. voltage (UCPV) 600 V
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 40 kA
Voltage protection level (UP) 2.1 kV
Voltage protection level for 5kA (UP) 1.5 kV
Method of mounting PCB on board
Enclosure dimensions (HxWxD) 52 mm × 18 mm × 45 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A

PCB on board, Type 2 /Class II multi-purpose single-pole SPD


PV DC SPD Type 2 with 2.7 kV Protection Level withanti-vibration pluggable module for use in PV DC system at
boundaries from LPZ 0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- PCB on board with slim size
- Easy replacing and anti-vibration due to
module releasing and locking system
- Visual and remote status indication

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M750-25/1N
Max. continuous operating d.c. voltage (UCPV) 750 V
Nominal discharge current (8/20 μs) (In) 20 kA
Max. discharge current (8/20 μs) (Imax) 25 kA
Voltage protection level (UP) 2.7 kV
Voltage protection level for 5kA (UP) 1.9 kV
Method of mounting PCB on board
Enclosure dimensions (HxWxD) 52 mm x 18 mm x 45 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity 125 Vac / 1 A, 1 25 Vdc / 0.2 A
30
WWW.CONNECTWELL.COM

PCB on board, Type 2 /Class II multi-purpose single-pole


PV DC SPD Type 2 with 1.5 kV Protection Level compact SPD for use in PV DC system at boundaries from LPZ
0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- PCB on board with slim size
- Remote status indication
- Gold-plating contactor of microswitch

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M500-20
Max. continuous operating d.c. voltage (UCPV) 500 V
Max. continuous operating a.c. voltage (UC) 385 V
Nominal discharge current (8/20 μs) (In) 10 kA
Max. discharge current (8/20 μs) (Imax) 20 kA
Voltage protection level (UP) 1.5 kV
Method of mounting PCB on board
Enclosure dimensions (HxWxD) 34 mm x 14 mm x 30 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity SELV / 1 A

PCB on board, Type 2 /Class II multi-purpose single-pole


PV DC SPD Type 2 with 1.8 kV Protection Level compact SPD for use in PV DC system at boundaries from LPZ
0B-1 and higher

Features:
- Non-destructive screening technology for MOV
- Reliable thermo disconnect device
- High discharge capacity
- PCB on board with slim size
- Remote status indication
- Gold-plating contactor of microswitch

TECHNICAL INFORMATION ORDERING INFORMATION


Technology MOV With changeover contact SPV2M670-20
Max. continuous operating d.c. voltage (UCPV) 6700 V
Max. continuous operating a.c. voltage (UC) 510 V
Nominal discharge current (8/20 μs) (In) 10 kA
Max. discharge current (8/20 μs) (Imax) 20 kA
Voltage protection level (UP) 1.8 kV
Method of mounting PCB on board
Enclosure dimensions (HxWxD) 34 mm x 14 mm x 30 mm
Operating status/fault indication Green / Red
Type of remote signaling contact Changeover contact
Switching capacity SELV / 1 A
.com

CONNECTWELL INDUSTRIES PVT. LTD.


D - 7, PHASE 2, M.I.D.C.,
DOMBIVLI - 421 204, INDIA
TEL.: + 91 251 7120 600 / 6762 600
FAX: + 91 251 7120 700
connect@connectwell.com

TERMINAL BLOCKS INTERFACE MODULES

You might also like