1. General
The Didacta Computerized Boiling Point Heat Transfer Unit T108/9D/C (Code 953809) is designed to display the various
types of boiling to change the intensity of the heat flow. More precisely, can be reproduced the nucleate and the film boiling
and it can plot the so-called "pool boiling" which is the basis of the design of the systems with the steam boiler. The
experiment is performed with environmentally-friendly, special low boiling point liquid.
A transparent vessel allows to observe the evaporation process at the heated cylinder. The cylinder operates as a fire tube
heated from the inside. An integrated water-cooled condenser allows for a continuous boiling process. The special liquid
used evaporates at low temperatures.
An automatic data acquisition and analysis system for Personal Computer allows to take the measurements automatically, to
plot the curves on screen or print them out, to store the experimental data on disk or print them.
The unit is supplied with manuals that describe each component of the system, installation and utilization procedures and
give many exercises.
2. Composition and description
Bench top unit
Heating element, 300W, continuously adjustable
Cooler: coil type, made of copper
Transparent process tank, approx. 3 litres
Copper piping
CFC free evaporation liquid
Safety valve, adjustable 1...4bar
Pressure switch for additional protection of heating circuit, adjustable
Pressure gauge with analogic output
Power transducer with analogic output
Flow rate transducer with analogic output
No. 5 temperature sensors with analogic output
DIDACTA Italia S.r.l. - Strada del Cascinotto, 139/30 - 10156 Torino - Italy
Tel. +39 011 2731708 - Fax +39 011 2733088 - http://www.didacta.it - E-mail: info@didacta.it
Data acquisition and analysis software
The acquisition and analysis software operates under MS-Windows and allows to capture data from the transducers located
on the plant.
So it is possible to monitor the plant by displaying on the PC screen, in real time, the acquired parameters and to manage
alarm signals, when a parameter goes out of range.
The software allows to display on the screen or to print the diagrams of the acquired data as a function of time. Acquired
data can be saved onto disk in ASCII format. Besides it is possible to carry out simulations by introducing data through the
keyboard.
3. Experiments
Different forms of evaporation (nucleate, film boiling)
Heat transfer coefficient
Effect of temperature and pressure on the evaporation process
4. PC minimum configuration required
PC, Hard Disk available space 3 GB min., RAM 4 GB, CD/DVD, USB port.
Microsoft Operating system.
Graphic printer.
5. Required services
Electrical power supply: 110/220V, single-phase, 50/60 Hz; 0.5 kW.
Water supply: from mains (150 l/h max)
6. Weight and dimensions
Weight (empty): 50 kg approx.
Dimensions: 900x500x900 h mm approx.
In any time and without notice, Didacta Italia can carry out any appropriate modification on the product details, always
maintaining their main features, according to the designing and teaching necessity. Page 2