Task 70−41−03−380−007:
WARNING: TOXIC FUMES, FROM OVENS USED FOR FUSING COATINGS, MUST
BE ABLE TO FLOW TO THE OUTDOORS SO THAT PERSONNEL DO
NOT BREATHE THESE GASES.
A. Procedure
(6) Air dry or dry in oven at 180° − 200°F (82° − 93°C) until
a dry, non−glossy appearance and medium brown color is
obtained.
(10) Air dry or dry in oven at 180° − 200°F (82° − 93°C) until
all water is evaporated and there is a dry, non−glossy
appearance.