Professional Documents
Culture Documents
RCC Section Drawing
RCC Section Drawing
Sr. No. Beam Size Straight Straight Curt. Bar Extra Top Stirrups Stirrups
Group BxD Top Bar Bott. Bars Middle 0.6L Ends L/4 End zone L/4 Middle half
01 FB0 150 X 380 2 - 10 Dia 2 - 12 Dia --- --- 08 dia - 150 c/c 08 dia - 175 c/c
Min. Ld
02 FB1 150 X 380 2 - 10 Dia 2 - 12 Dia --- 1 - 12 Dia 08 dia - 150 c/c 08 dia - 200 c/c beyond column
Continue Extra tops at Internal
face
continous supports
03 FB2 150 X 380 2 - 12 Dia 2 - 12 Dia --- 1 - 12 Dia 08 dia - 150 c/c 08 dia - 200 c/c * Compulsary
Column links at
for All Top , Bottom & extra top column-beam junction
FB3 150 X 380 2 - 12 Dia 2 - 12 Dia 1 - 12 Dia 1 - 12 Dia 08 dia - 125 c/c 08 dia - 175 c/c end zone stirrups Remaining span
04 Extra Tops Bars
( upto L/4 ) stirrups upto L/4 400 mm are necessary
End Bent 400 mm
Min. 300mm
05 FB4 150 X 380 2 - 12 Dia 2 - 12 Dia 1 - 12 Dia 2 - 12 Dia 08 dia - 125 c/c 08 dia - 175 c/c
06 FB5 150 X 380 2 - 12 Dia 2 - 12 Dia 2 - 12 Dia --- 08 dia - 125 c/c 08 dia - 175 c/c
16mm dia
07 FB6 150 X 450 2 - 12 Dia 2 - 16 Dia --- 1 - 16 Dia 08 dia - 100 c/c 08 dia - 175 c/c Anchor Pin
50mm max Curtail Bar
first stirrup Position at Bottom middle 0.6L
08 FB7 230 X 380 2 - 16 Dia 3 - 16 Dia --- --- 08 dia - 150 c/c 08 dia - 150 c/c L=Length of Beam * IMPORTANT
09 FB8 230 X 380 3 - 12 Dia 3 - 12 Dia --- --- 08 dia - 150 c/c 08 dia - 150 c/c Column
50% Bottom bars are to be
Width/Depth Column
lapped at L/4 from support of column
(if Reqd.)
10 FB9 230 X 380 2 - 12 Dia 2 - 16 Dia 1 - 12 Dia 2 - 12 Dia 08 dia - 125 c/c 08 dia - 175 c/c
TYP. DETAILS OF LONGITUDINAL SECTION THROUGH BEAM.
11 FB10 230 X 450 2 - 16 Dia 3 - 16 Dia --- 3 - 16 Dia 08 dia - 100 c/c 08 dia - 150 c/c
12 FB11 230 X 450 2 - 16 Dia 3 - 16 Dia 1 - 16 Dia 3 - 16 Dia 08 dia - 100 c/c 08 dia - 150 c/c
13 FB12 230 X 530 3 - 16 Dia 3 - 16 Dia 2 - 16 Dia 3 - 16 Dia 08 dia - 100 c/c 08 dia - 125 c/c
Alt. bent up Steel continue from one span to other
14 FBR0 150 X 450 3 - 12 Dia 2 - 12 Dia --- --- 08 dia - 125 c/c 08 dia - 125 c/c
Alt. Bent up bars 0.3L1 0.3L2
15 FBR1 150 X 380 3 - 12 Dia 2 - 12 Dia --- --- 08 dia - 125 c/c 08 dia - 125 c/c
16 FBR2 150 X 380 4 - 16 Dia 2 - 12 Dia --- --- 08 dia - 125 c/c 08 dia - 125 c/c
17 FBR3 230 X 450 3 - 16 Dia 2 - 16 Dia --- --- 08 dia - 100 c/c 08 dia - 150 c/c
in cantilever portion in back beam portion 0.2L1 0.25L1 0.25L2
18 FBR4 230 X 450 4 - 16 Dia 2 - 16 Dia --- --- 08 dia - 100 c/c 08 dia - 150 c/c
in cantilever portion in back beam portion L1 L2
19 FBR5 230 X 450 5 - 16 Dia 3 - 16 Dia --- --- 08 dia - 100 c/c 08 dia - 100 c/c Slab Discontinuous end Slab continuous end
20 FBR6 230 X 380 3 - 16 Dia 2 - 12 Dia --- --- 08 dia - 125 c/c 08 dia - 125 c/c DETAILS OF BAR BENDING FOR SLABS
21 HB 200 X 125 2 - 10 Dia 2 - 12 Dia --- --- 08 dia - 175 c/c 08 dia - 175 c/c
22 HB1 200 X 125 2 - 12 Dia 2 - 12 Dia --- --- 08 dia - 150 c/c 08 dia - 150 c/c
DETAILS OF SLAB - AT SECOND SLAB LEVEL
Slab Thick Steel along Extra Top. Remark
Width (short) Length (long)
one way End bent 08 mm @ 125 c/c LEGENDS :
S1 125 08 mm @ 150 c/c 08 mm @ 150 c/c ---- plain jali Bent back Chimta
Min.300mm
S2 125 08 mm @ 100 c/c 08 mm @ 100 c/c ---- one way
300mm
plain jali
125 08 mm @ 175 c/c 08 mm @ 125 c/c 08 mm @ 250 c/c one way Beam As
S3 Slab at Beam Bottom
per schdule
125
S4 125 08 mm @ 175 c/c 08 mm @ 175 c/c 08 mm @ 300 c/c Two Way
S5 125 08 mm @ 150 c/c 08 mm @ 175 c/c 08 mm @ 300 c/c Two Way
CS 125 08 mm @ 150 c/c 08 mm @ 175 c/c Cantilever 08 mm @ 175 c/c TYPICAL STIRRUP
Bent back Chimta ---- SECTION A-B
SS1 150 08 mm @ 175 c/c 12 mm @ 150 c/c ---- Stairs / RING
Note :Alternate bent up of one span shall go to L/4 of other span.
> Provide extra tops at discontinuous ends.
IMP NOTES :- 6. No concreting shall be done without seeking Structural Engineer's Structural Consultants
comment in writing.
Client : NORTH Sheet Title :
1. All work shall be strictly executed as per the drawing. 7. Clear Cover to R/F bars shall be - Footing 50mm, Column 40mm ,Beams 30mm,
2. Structure designed for G+4 Including Future Provision (5 Slabs only). Slabs 20mm. Mr. S.A.G. Qureshi Sahab
if not found at site, foundations must be redesigned. 8. Developement/Lap length shall be used as 50 times dia of bar for beams , Structural Design Details Er. Shaikh Imran
3. Concrete Grade M20 and Steel Fe500 shall be used.
4. Fe500 grade Steel shall only be used if 14.5 % elongation is assured
Where bent used it shall be 42 times dia of bar.
9. Stripping time Shall be as per I.S.456-2000. N At SECOND slab level (DCE, M.E. Structure)
as per Codel Provisions. 10. False work/ Shuttering Stability, supervision is responsibility of contractor.
5. Concrete Mix design shall be followed. 11. Top bars are to be lapped at center of beam & Project Title : ( 02 of 02)
Reg.No. E-725/18
bottom bars at L/4 from column face (lap length =50xbar diameter).
12. Column bars lapping should be done at center of the column.
02 - Structural Schedule Aurangabad
13. If crush sand used for concreting work, it shall have proper mix design from lab. Proposed Apartment Building, & Detailing +91 88 55 866 787
14. Structural analysis & design is done for Gravity loadings only.
15. Any discrepancy shall be asked and discussed to Structural Engineer. At Beed Bypass, Aurangabad.
*** THIS DRAWING SHALL BE USED FOR SECOND SLAB LEVEL ONLY. Drawing No. 07-b Date : 13/02/2019 Revision No : 0