Professional Documents
Culture Documents
Omniswitch 9000E Chassis Lan Switch Datasheet en
Omniswitch 9000E Chassis Lan Switch Datasheet en
OMNISWITCH 9000E
CHASSIS LAN SWITCH
The Alcatel-Lucent OmniSwitch® 9000E Chassis LAN Switch (CLS) family is a high-capacity
core switch that addresses large enterprise network needs for secure and highly available
core switches to support voice, data and video solutions. The OmniSwitch 9000E CLS, part of
the OmniSwitch portfolio, is also ideal for use in data centers or metro Ethernet environments
because it was designed for deployments requiring high capacity, scalability and virtualization.
Chassis models
Several chassis options are offered to meet density requirements.
OMNISWITCH 9700E/OMNISWITCH 9702E OMNISWITCH 9800E
NUMBER OF SLOTS
Chassis management module (CMM) 2 2
Network interface (NI) 8 16
Power supply (AC/DC) 3 4
PHYSICAL
Height (19-in. and 23-in. rack mount) 11U 17U
Dimensions (HxWxD) 48.9 cm x 44.2 cm x 44.0 cm 75.6 cm x 44.2 cm x 44.0 cm
(19.25 in x 17.4 in x 17.3 in) (29.75 in x 17.4 in x 17.3 in)
Weight (loaded/empty) 60 kg (130 lb)/25 kg (56 lb) 85 kg (190 lb)/36 kg (80 lb)
ENVIRONMENT
Operating temperature 0°C to 45°C (32°F to 113°F) 0°C to 45°C (32°F to 113°F)
Storage temperature -20°C to 85°C (-4°F to 185°F) -20°C to 85°C (-4°F to 185°F)
Operating humidity 10% to 90% (non-condensing) 10% to 90% (non-condensing)
Storage Humidity 10% to 95% (non-condensing) 10% to 95% (non-condensing)
Cooling Front-to-back cooling Front-to-back cooling
Power (chassis + fan tray) <80 W <80 W
Heat dissipation (fully loaded – worst case) <3485 BTU/hr <6480 BTU/hr
Altitude 0 to 4 km (13,000 ft) 0 to 4 km (13,000 ft)
Modules
The table below lists the choice of modules available for the OmniSwitch 9000E CLS family.
DESCRIPTION POWER
MANAGEMENT MODULES
OS9700E-CMM OmniSwitch 9700E Chassis Management Module <30 W
OS9702E-CMM OmniSwitch 9702E Chassis Management Module <30 W
OS9800E-CMM OmniSwitch 9800E Chassis Management Module <40 W
NETWORK INTERFACES
OS9-XNI-U2E 2 unpopulated ports of 10GBase-X (XFP MSA) <32 W
OS9-XNI-U12E 12 unpopulated ports of 10GBase-X (SFP+ MSA) <40 W
OS9-GNI-U24E 24 unpopulated ports of 1000Base-X MiniGBIC (SFP MSA) <40 W
OS9-GNI-P24E 24 ports of 10/100/1000Base-T/TX (RJ-45) up to 30W of PoE per port <54 W
OS9-GNI-C24E 24 ports of 10/100/1000Base-T/TX (RJ-45) <55 W
All network interfaces and transceivers are hot-swappable and can be used in any available NI slot of any OmniSwitch 9000E CLS chassis.
Power supplies
All OmniSwitch 9000 CLS models support redundant and hot-swappable AC and DC power supplies.
OS9-PS-0725A OS9-PS-0725D
Input voltage 100 V AC to 250 V AC (auto-ranging) -48 V DC
Input current (max) 7.9 A (110 V)4.0 A (220 V) 17.8 A (-48V)
Operating frequency 47 Hz to 63 Hz –
Efficiency 83% 85%
Maximum output power 725 W 725 W
Compliance and certifications • Full configuration and reporting using Real-time diagnostics of fiber connections
Emission
Simple Network Management Protocol for early detection of optical signal
(SNMP) v1/2/3 across all OmniSwitch deterioration
• FCC CFR 47 part 15 (Class A)
families to facilitate third-party NMS • Link Monitoring: link flap detection
• ICES-003 (Class A)
integration and link error counts to identify bad
• CE marking for European countries (Class A)
• Remote switch access using Telnet or connections and automatically make
• VCCI (Class A) Secure Shell (SSH) adjustments to
• AS/NZS 3548 (Class A) • File upload using USB, TFTP, FTP, SFTP, or use the links that are good
• EN 55022:2006 (Emission Standard) SCP for faster configuration • Time Domain Reflectometry (TDR): used
• EN 61000-3-2:2006 • Human-readable ASCII-based configuration for locating break or other discontinuity
files for off-line editing, bulk configuration in copper cable
• EN 61000-3-3:1995 +A2:2005
and out-of-the-box auto-provisioning Network configuration
Immunity
• Onboard flash for, for example, storing • Auto-negotiating 10/100/1000 ports
• IECEN 55024:1998 +A1:2001 +A2:2003
switch configuration, monitoring logs and automatically configure port speed and
• EN 61000-4-2:2001
AOS images duplex setting
• EN 61000-4-3:2002
• Status LEDs for at-a-glance monitoring of • Auto MDI/MDIX automatically configures
• EN 61000-4-4:2004 system, power and line card status transmit and receive signals to support
• EN 61000-4-5:2001 Monitoring and troubleshooting straight-through and crossover cabling
• EN 61000-4-6:2004 • Local (on the flash) and remote server • BOOTP/DHCP client with option 60
• EN 61000-4-8:2001 logging: Syslog and command log allows auto-configuration of switch IP
• EN 61000-4-11:2004 information for simplified deployment
• Port-based mirroring for troubleshooting
Safety agency certifications and lawful interception; supports four • DHCP v4/v6 relay to forward client
sessions with multiple sources-to-one requests to a DHCP server
• US UL 60950
destination • Alcatel-Lucent Mapping Adjacency
• IEC 60950-1:2001; all national deviations
• Policy-based mirroring allows selection Protocol (AMAP) for building topology
• EN 60950-1:2001; all deviations
of the type of traffic to mirror by using maps
• CAN/CSA-C22.2 No. 60950-1-03
QoS policies • IEEE 802.1AB LLDP with MED extensions
• NOM-019 SCFI, Mexico for automated device discovery and IP
• Remote port mirroring facilitates passing
• AS/NZ TS-001 and 60950:2000, Australia mirrored traffic through the network to phone provisioning
• UL-AR, Argentina a remotely connected device • Multiple VLAN Registration Protocol
• UL-GS Mark, Germany • Port monitoring feature allows capture (MVRP) and GARP VLAN Registration
of Ethernet packets to a file to assist in Protocol (GVRP) for 802.1Q/1ak-compliant
• EN 60825-1:1993 +A1:1997 +A2:2001
troubleshooting VLAN pruning and dynamic VLAN creation
Laser,
• sFlow v5 and RMON: For advanced • Dynamic Virtual Network Profiles
• EN 60825-2:2004 Laser
monitoring and reporting capabilities for (vNP) for automating virtual machine/
• CDRH Laser
statistics, history, alarms and events device attachment to the network with
guaranteed SLA
• IP tools: Ping and traceroute
DETAILED PRODUCT FEATURES • ITU-T Y.1731 and IEEE 802.1ag Ethernet
• Auto-QoS for switch management and IP
Simplified manageability phone traffic
OA&M: Connectivity Fault Management
Management interfaces and performance measurements (layer-2 • Network Time Protocol (NTP) for network-
• Dedicated EMP RJ-45 port for ping and link trace) wide time synchronization
management and diagnostics • IEEE 802.3ah Ethernet in the First Mile
• Intuitive, familiar CLI reduces (EFM) for link monitoring, remote fault Resiliency and high availability
training costs detection, and loopback control (layer-1 • Smart continuous switching technology
• Easy-to-use, point-and-click, web-based ping) for instantaneous and transparent CMM
element manager (WebView) with built-in • Unidirectional Link Detection (UDLD) failover in redundant CMM configuration
help for easy configuration detects and disables unidirectional links on • MC-LAG active-active dual homing over
• Integrated with Alcatel-Lucent OmniVista® fiber optic interfaces IEEE 802.3ad (LACP) interfaces enabling
2500 Network Management System (NMS) • Digital Diagnostic Monitoring (DDM): a highly resilient architecture
Contact your reseller of Alcatel-Lucent Enterprise solutions for additional information on country-specific power cords and a complete list
of our SFP and XFP transceivers and MRJ21 cables.
enterprise.alcatel-lucent.com Alcatel-Lucent and the Alcatel-Lucent Enterprise logo are trademarks of Alcatel-Lucent. To view
other trademarks used by affiliated companies of ALE Holding, visit: enterprise.alcatel-lucent.com/trademarks. All other trademarks
are the property of their respective owners. The information presented is subject to change without notice. Neither ALE Holding nor
any of its affiliates assumes any responsibility for inaccuracies contained herein. (February 2016)