CONTROL NO : ER 09/A

REV : 0 DTD : JAN,08

INCINERATOR OPERATING PROCEDURE


 PUT DO SUBSTITUTION SWITCH IN (NOR POSITION)

 PUT PILOT BURNER SWITCH (ASSIST IN NOR POSITION)

 PUT ALL MANUAL OPERATING SWITCH IN AUTO POSITION

 CHANGE OVER EACH V/V SO THAT THE WO WILL BE SUPPLIED.

 TURN ON POWER SWITCH

 PRESS RESET SWITCH TO MAKE INITIAL RESET

 PRESS AUTO START SWITCH

 THE INDUCED FAN AND BURNER MOTOR/WO P/P WILL START ON


RUNNING TO PERFORM THE HOT CIRCULATION OF WO AS WELL AS
FURNACE PRE PURGE WHEN PRESET TEMPERATURE OF APPROX 60
DEG C REACHED WITH THE INCREASE OF WO TEMP, WO
INCINERATION IS MADE PRACTICABLE.

 AFTER STARTING THE COMBUSTION OF WO REG FLOW OF WO WITH


WO FLOW REG V/V, SO THAT COMBUSTION CHAMBER O/L EXH.GAS
TEMP WILL FALL WITH IN RANGE 900-950 DEG C.

 WHEN WO BURNER ON/OFF TAKES PLACE FREQUENTLY, THROTTLE


FLOW OF WO.

 UPON COMPLETION OF THE WO INCINERATION THE WO SHUT OFF V/V


BECOMES CLOSED. WHERE PILOT BURNER PUT TO USE THE PILOT
BUNER ALSO GOES OUT AND THE INDUCED FAN ONLY IS PUT IN
OPERATING CONDITION.

 WHEN WO INCINERATION HAS TO BE ALLOWED TO STOP, PRESS


AUTO STOP SWITCH.

 CLOSE SUCH MAIN V/VS AS ATOMISING AIR MAIN V/V AND WO


AGITATOR AIR MAIN V/V ETC.

CHIEF ENGINEER