INFORME N°02-2019 MODELAMIENTO AMBIENTAL

DE: Wendy Rocio Roque Quispe


PARA: MSc.Sonia Yufra Cruz
FECHA; 24 de mayo del 2019
ASUNTO: Informe de laboratorio Screen View
_________________________________________________________________________

CASO 01

A. RURAL

Automated Distance Vs. Concentration


Terrain Height = 0.00 m.
16

14

12

10
(ug/m**3)

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000
Distance (m)

ANÁLISIS:

TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
3850. 2.425 4 2.5 3.5 800.0 306.75 238.64 96.04 NO
5200. 4.933 4 2.5 3.5 800.0 306.75 308.66 108.34 NO

ANÁLISIS:
***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 15.00 15970. 0.

ANÁLISIS:

B. URBANO

Automated Distance Vs. Concentration


Terrain Height = 0.00 m.

70

60

50
(ug/m**3)

40

30

20

10

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000
Distance (m)
ANÁLISIS:
DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA
(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M)
Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------
------ -----
3850. 38.58 4 2.5 4.4 800.0 264.23 389.35
370.15 NO
5200. 28.28 4 2.5 4.4 800.0 264.23 476.39
457.41 NO

ANÁLISIS:

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 69.82 1580. 0.

ANÁLISIS:
CASO 02

A. ESTABILIDAD D

Automated Distance Vs. Concentration


Terrain Height = 0.00 m.
16

14

12

10
(ug/m**3)

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000
Distance (m)

TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
3850. 2.425 4 2.5 3.5 800.0 306.75 238.64 96.04 NO
5200. 4.933 4 2.5 3.5 800.0 306.75 308.66 108.34 NO

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 15.00 15970. 0.

B. ESTABILIDAD A
Automated Distance Vs. Concentration
Terrain Height = 0.00 m.

100
90
80
70
(ug/m**3)

60
50
40
30
20
10

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000
Distance (m)
ANÁLISIS:

DIST CONC U10M USTK MIX HT PLUME SIGMA


SIGMA
(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M)
Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------
------ -----
3850. 24.89 1 2.5 2.9 800.0 348.57 682.19
5000.00 NO
5200. 19.23 1 2.5 2.9 800.0 348.57 882.68
5000.00 NO

ANÁLISIS:

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 98.51 802. 0.

ANÁLISIS:
CASO 3
A. ALTURA DE CHIMENEA: 100
Automated Distance Vs. Concentration
Terrain Height = 0.00 m.
16

14

12

10
(ug/m**3)

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000
Distance (m)

TERRAIN HEIGHT OF 0. M ABOVE STACK BASE USED FOR FOLLOWING DISTANCES ***

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z (M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------ ------ -----
3850. 2.425 4 2.5 3.5 800.0 306.75 238.64 96.04 NO
5200. 4.933 4 2.5 3.5 800.0 306.75 308.66 108.34 NO

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 15.00 15970. 0.

B. ALTURA DE CHIMENEA: 10
Automated Distance Vs. Concentration
Terrain Height = 0.00 m.

140

120

100
(ug/m**3)

80

60

40

20

0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 22000
Distance (m)
ANÁLISIS:

DIST CONC U10M USTK MIX HT PLUME SIGMA SIGMA


(M) (UG/M**3) STAB (M/S) (M/S) (M) HT (M) Y (M) Z
(M) DWASH
------- ---------- ---- ----- ----- ------ ------ ------
------ -----
3850. 18.21 1 2.5 3.5 800.0 306.75 775.28
2035.76 NO
5200. 14.86 1 2.5 3.5 800.0 306.75 949.99
3108.06 NO

ANÁLISIS:

***************************************
*** SUMMARY OF SCREEN MODEL RESULTS ***
***************************************

CALCULATION MAX CONC DIST TO TERRAIN


PROCEDURE (UG/M**3) MAX (M) HT (M)
-------------- ----------- --------- -------
SIMPLE TERRAIN 77.45 719. 0.

ANÁLISIS:
CASO 4. ECA

CASO 1. CASO 2. CASO 3. CASO 4. ALTURA ECA PM 2.5


RURAL URBANO ESTABILIDAD A DE CHIMENEA 10m [μg/m3]
[μg/m3] [μg/m3] [μg/m3] [μg/m3]

15.00 69.82 98.51 77.45 50

ANÁLISIS: