I. Introduction:
This is a user guide for installing the RET controller GUI and the required driver for the
application. It also contains operating instructions for the GUI, antenna file and firmware
download, and clearing COM Ports.
2. System Requirement
Software Specifications
6. Follow the setup wizard and click Next, Install, allow installation, and Finish to
complete the installation. Screens below are the same for setup23 or higher.
7. The RET Controller GUI icon will be automatically installed on your desktop.
11. Follow the installation wizard below and click next for each window.
• If the com port is all used up, go to Clearing Com Port section VII, Pg. 9
of this MOP.
3. When Launching the GUI, the screen or window display should look like figure 1
with the Commands and Properties window showing side by side
Properties Window
Commands Window
progress
i. Operator data such as Antenna Serial Number, Base Station and Sector
Id…etc.
j. The icon is for saving the report in .txt format for the devices from
the ALD list. See figure3.
Homerun
SBT to SBT
BTS ANT BTS ANT
Smart Bias T Smart Bias T
RETs
AISG AISG
AISG
Daisy Chain Cable
1. Follow the connection diagram in Figure 4 which shows the various RET system
diagram connection to the RET controller and PC.
• Homerun cable to RET
• Smart Bias T to Smart Bias T to RET
• Smart Bias T to AISG TMA to RET
2. Verify that Com Port is selected by selecting and clicking on the Com# to
the right of Serial Port: See Figure 2.
3. Always perform a bus reset prior to starting a scan by clicking the icon.
4. Click the Scan button to scan for RETs (ALDs).
5. After the Scan is completed, the list of devices will show in the properties box
6. Select the device you want to control and configure from the Properties Window
drop down list or single click on the ALD# and ALD fields will load on the
Command window. Single Click will load data when there are multiple ALDs.
• GET ALL DATA will also read from the device and load ALD fields
• Verify that the antenna model is correct, if not refer to ACF Download
section for instructions to load the correct Antenna file.
7. Calibrate the RET – RET CALIBRATE
8. Set/get the Tilt within the Min/Max range – SET RET TILT / GET RET TILT
9. Verify that the Results shows “Success” and verify that there are no alarms –
GET ALARMS. See Table 1 for alarm lists.
10. Configure the Operator Data such as Antenna Serial#, Base Station Id, and Sector
Id…….Click Set for each items to write to the RET.
11. Save a report for the Devices from the ALD list in the Properties window.
• Name the report and save
• Allow time for the report to generate, the GET ALL DATA will show
Running while each motor is being accessed to get the data for the report
• Report will be generated for ALL ALDs connected
12. Alarms are listed below in Table 1 with recommended actions
Three RETs
C4 = Low Band
A4-ANT 1 = High
FW Rev A4-ANT 2 = High
Two RETs – Same Band
5. Select the antenna file per the selection guide in section V - step 2 and Figure 5.
6. Double click on the antenna file or click Open to load to the RET
7. The Antenna Model Number will update to the new file
8. Calibrate the RET
9. Done
8. Done