Professional Documents
Culture Documents
Surveyor Release Notes
Surveyor Release Notes
7 Patch 4
Release Notes
June 2015
Table of Contents
Introduction ..................................................................................................................................1
Special Notes.................................................................................................................................1
New Features.................................................................................................................................2
System Requirements .................................................................................................................2
Supported Wi-Fi Adapters .........................................................................................................4
Bug Fixes ........................................................................................................................................5
Known Issues ................................................................................................................................6
Release History .............................................................................................................................7
Technical Support ........................................................................................................................7
Introduction
AirMagnet Survey PRO is a powerful and easy-to-use survey tool that provides WLAN
professionals with everything they need to both accurately plan and survey any 802.11
a/b/g/n/ac wireless network.
Special Notes
When using any of the USB wireless adapters, wireless profiles may need to be re-
created when the adapter is plugged into a different USB port—as profiles are stored
based on the port, not the adapter itself.
The Cisco Prime NCS/WCS integration feature requires a Cisco “Plus” license.
The use of 802.11ac adapters are supported under the following operating Systems:
Microsoft® Windows 7 Enterprise/Professional/Ultimate or Microsoft Windows 8
Pro/Enterprise 32 and 64 bit or Microsoft Windows 8.1 Pro/Enterprise 64 bit. They are
not supported under Windows XP.
When using an 802.11ac adapter, some features of AirMagnet Survey are unavailable,
for example, VoFi surveys, roaming control for Active or Active IPERF surveys,
indication of channels being scanned and the Station tab in the Passive Survey window.
Recommended AP settings when performing AP-on-a-Stick active surveys with
802.11ac Adapters:
Page 1 of 8 AirMagnet Survey PRO 8.7 Patch 4
Release Notes
SVY-v8.7 P4-35819-RLN-01-06/2015
o AP configured as DHCP Server and Gateway configured with AP’s IP address.
Wireless adapter configured for DHCP.
o AP configured as DHCP Server and Gateway not configured. Wireless adapter
configured for DHCP.
o AP not configured as DHCP Server, Static IP assigned to the AP with Gateway
not configured. Wireless adapter configured for static IP in the range of APs IP
address.
If you are upgrading from 8.5 or earlier versions of AirMagnet Survey and had created
custom reports or are importing custom reports from earlier versions, you will need to
edit the custom reports before running them. If you run the report before editing, the
error ‘An invalid argument was encountered’ will occur and you will need to exit and
re-launch AirMagnet Survey. To edit a custom report:
o Click the Reports tab.
o Right-click the custom report and select Edit. This opens the Editing Report
Template dialog.
o Select the General Information tab and click Translation. This opens the Report
Translation dialog.
o Check Use Default
o Click Save
o Select the Report Template tab and click Restore Default
o Click OK and then click OK to save changes and close the Editing Report
Template dialog.
Reports tab: Delete Active IPERF Survey Sample Template, Active Survey Sample
Template, and Passive Survey Sample Template as they have been replaced by Active
IPERF Survey Report, Active Survey Report, and Passive Survey Report, respectively.
Running the old template will result in an error message.
You must uninstall the demo version of Survey before installing the released version of
Survey PRO/Planner.
New Features
Bug fixes
System Requirements
Supported site map image formats: .bmp, .dib, .dwf, .dwg, .dxf, .emf, .gif, vsd, .jpg, .wmf,
.vdx or .png).
Bug Fixes
1. When a survey is run, the site plan .spi file in the project directory has an empty note
appended to the note field. Eventually, this string exceeds the length allowed when
reading the file and may cause the application to crash. (DE11907, DE11273)
Page 5 of 8 AirMagnet Survey PRO 8.7 Patch 4
Release Notes
SVY-v8.7 P4-35819-RLN-01-06/2015
2. When deleting a filtered or merged data file while it is open, the application may crash
(DE10432)
3. Deleting an AP placed on a floor plan in Survey View may cause the application to crash
(DE11725)
4. Intermittent crashes when refreshing heatmaps in Multi Floor Planner (DE11477)
Known Issues
This section documents some known issues with AirMagnet Survey.
1. Cisco Prime NCS/WCS AirMagnet planner export: A shift in the border rendering may
occur. The work around is as follows: After importing the project into Cisco Prime
NCS/WCS, select the building, click the floor plan, select “Map Editor,” maximize the
browser, click "click here." (DE2262)
2. Clicking “Yes” within Recalibrate prompt may not produce recalibrate push pins. The
work around is to try again using the measure tool. (DE2990)
3. Simulated noise level is not saved to the Sim- data file. (DE2870)
4. When using Multi Floor Planner, in an exported Building level report PDF, the blue,
purple, green color legends under 2D floor view may get replaced with a blurry image.
(DE3623)
5. With a virtual survey loaded, AirWISE may indicate the throughput threshold option as
“NA” when it should be “Available.” (DE3522)
6. When running Windows 7 64-bit, the RF Spectrum Report may show all spectrum data
points, not just those marked to be included in the report. (DE3390)
7. When using Multi Floor Planner, there may be an incorrect walls/areas offset after
recalibration if using a Visio image for the floor plan image. (DE3170)
8. When using Multi Floor Planner with imported Visio images, some floors may be
blackened out. (DE7879)
9. When creating a Planner project, if you create a wall that has multiple segments and then
change one or more segments to a different wall type, the change may not be saved.
(DE3040)
10. When using Multi Floor Planner, the user is not prompted to close and restart Multi Floor
Planner after making any changes to Display Performance, Sampling Density or Data
Processing. After making any of these changes, close and restart Multi Floor Planner.
(DE3778)
11. 802.11ac Spatial Stream: When spatial stream values changes during the survey, the new
values are not reflected in Bubble Help. (DE5540)
12. Performing iperf surveys in the 2.4GHz band for 802.11g/n using the Intel 7260 Wi-Fi
adapter may result in the loss of the downlink and “connection reset by peer” messages.
(DE5886)
Release History
06/2015: AirMagnet Survey PRO 8.7 Patch 4 (build 35819).
02/2015: AirMagnet Survey PRO 8.7 Patch 3 (build 35810).
10/2014: AirMagnet Survey PRO 8.7 Patch (build 35800).
08/2014: AirMagnet Survey PRO 8.7 (build 35764).
Technical Support
Fluke Networks' Gold Support is our comprehensive support and maintenance program that
offers expanded coverage for all AirMagnet products. All existing AirMagnet customers with
products under the annual maintenance and support program are automatically migrated to
the new Fluke Network's Gold Support program.
Benefits of the Gold Support program include:
Access to live 24 X 7 technical support.*
Highly trained technical experts to help with product installation, configuration,
best practices & troubleshooting on call 24 hrs a day including weekends and
through the night.
Multilingual technical support team.**
Free software updates/upgrades (new features and product enhancements) when
available.
Hardware support, repair and replacement for AirMagnet products.***