5.17. Following are the results of standard penetration tests in a granular soil deposit.
Depth (ft.) Standard penetration number, N60
5 11
10 10
15 12
20 9
25 14
What will be the net allowable bearing capacity of a foundation planned to be 6 ft. x 6 ft. ? let
Df = 3 ft. and the allowable settlement = 1 inch., and use the relationship presented in Eq.
(5.60).
2 𝑁60 𝐵+1 2
qnet (kip/ft ) =
4
( 𝐵
) 𝐹𝑑 𝑆𝑒 (for 𝐵 > 4 ft)
where
Data : B = 6 ft.
Se = 1 inch.
Df = 3 ft.
Question : qnet = …. kip/ft2
Solution : From Eq. (5.60)
𝑁60 𝐵+1 2
qnet =
4
( 𝐵
) 𝐹𝑑 𝑆𝑒
11 6+1 2 3
qnet =
4
( 6
) . [1 + 0,33 6] . 1