Experiment # 06: Implementing DC Biased Series (Positive & Negative) Clippers
Experiment # 06: Implementing DC Biased Series (Positive & Negative) Clippers
Apparatus
Oscilloscope 01
Function Generator 01
DC Power Supply 01
Resistor 01
Diode Silicon 01
Circuit Diagram
Procedure
1. Connecting the elements in a circuit on bread board as shown in the circuit diagram
2. Use a battery in series with a diode. This is called Biased Voltage.
3. Connect the function generator with input probe of the Clamper circuit.
4. Observe output voltages on oscilloscope by connecting the oscilloscope across the load resistor.
Observations:
TRIANGULAR
WAVE 3.25 713m
CIRCUIT NO 2
SINE WAVE
3.77 1.22
SQUAR WAVE
3.04 580
TRIANGULAR
WAVE
3.88 1.38
3.6v 5.7v
SINE WAVE
3.62 5.64
SQUAR WAVE
TRIANGULAR 3.44 5.68
WAVE
CIRCUIT NO 2
SINE WAVE
4.02 6.26
SQUAR WAVE
4.65 6.58
TRIANGULAR
WAVE 4.8 6.32