Comfort: Quick and Easy Installation Quick and Easy Installation
Comfort: Quick and Easy Installation Quick and Easy Installation
Draft prevention setting Ceiling soiling prevention 256mm (50-71C) 261mm (50-71C) Easy removal of corner cover
Air direction Standard setting1 setting2 (field setting) 303mm (100-140C) It is possible to easily
(field setting) 298mm (100-140C)
remove without use
For shops with of screws or tools.
Desired situation For gentle drafts. When drafts are unwanted. light coloured ceilings that
must be kept spotless.
Designer panel
Suitable for high ceilings 125/140C 46.0 43.0 40.0 36.0 32.5
Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level. Easy height adjustment Ease in temporary hanging
Criteria for ceiling height and number of air discharge outlets Each corner of the unit has an
Standard Setting Setting
(Ceiling height is reference value) adjuster pocket that lets you
of decoration panel
Number of air discharge outlets used easily adjust the unit's In addition to the temporary
50-71C 100–140C suspended height. hanging fixtures in 2 places
3.6 4.2 All round 4-way 3-way 2-way All round 4-way 3-way 2-way normally used, corner part
3.2 m flow flow flow flow flow flow flow flow Note: mounting fixtures in 4 places
m m If the wireless remote controller is installed,
Standard 2.7 m 3.1 m 3.0 m 3.5 m 3.2 m 3.4 m 3.6 m 4.2 m are provided.
Ceiling a signal receiver unit is housed in one of
High ceiling 3.0 m 3.4 m 3.3 m 3.8 m 3.6 m 3.9 m 4.0 m 4.2 m the adjuster pockets. Corner part mounting
height
High ceiling 3.5 m 4.0 m 3.5 m - 4.2 m 4.5 m 4.2 m - fixtures (in 4 places) Temporary hanging
fixtures (in 2 places)
Note:
When all round flow is selected, ceilings up to 4.2 m in height
can be accommodated. (100-140C)
The aforementioned is for standard panels. See the installation manual for designer panels.
Factory settings are for standard ceiling height and all-round flow.
Temporary placement of control Drain pump
High ceiling settings (1) and (2) are set with the remote controller by field setting.
High-efficiency filters are not available for high ceiling applications. box lid Equipped as standard
accessory with
Because the control box lid can be temporarily hung 850 mm
Humidity sensor on the unit, there is no need to climb down the
850 mm lift.
Not only temperature but also humidity is stepladder to retrieve it.
detected, and adjustments are made for 175 mm
comfortable air conditioning.
should be changed once Prevents mould and microorganisms growing out of the when multiple units are surface *High-efficiency filter, ultra long-life filter, and
fresh air intake
every two to three years.) dust and moisture that adheres to the filters. installed.
25 26