Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 6

Name of Project: 1.

5MW PANICUAN RIVER MINI HYDRO POWER PLANT


Project Location: CAMARINES SUR
Project Owner:

PENSTOCK ANCHOR BLOCK # 12 STRUCTURAL ANALYSIS

Design Parameters:

Material type = A36 STEEL


wt. Of pipe = 7800 Kg/m3
Unit wt. of Conc.= 24 Kn/m3
wt. Of penstock = 1.224 Kn/m
wt. Of water = 6.239 Kn/m
ø Pipe = 0.9 m
Pipe thk. = 6.35 mm
Gross Head = 99.89 m
Pipe Area = 0.636 m2
Pipe cross Area= 0.016 m2
Q= 1.97 (Design Discharge)
V= 3.1 (Design Velocity)
f= 0.6 (coefficient of friction of pipe to pier)
f' = 7.313 (friction of expansion joint per meter of circumference)
w= 9.81
g= 9.81
øu = 30 slope angle above anchor
ød = 20 slope angle below anchor
dist. Of anchor to uphill anchor = 103.36 m
dist. Of anchor to downhill anchor = 24.5 m
dist. Of uphill anchor to expansion us = 0 m
dist. Of downhill anchor to expansion ds = 0 m
dist. Of anchor to expansion us = 0 m
dist. Of anchor to expansion ds = 0 m

FORCES DIAGRAM :
TABLE OF FORCES:

FORCES Considering Expanding Considering Contracting


Condition Condition
F1= waH 623.23 Kn 623.23 Kn

F2= wQV/g 6.107 Kn 6.107 Kn

F3= Pusinøu 0 Kn 0 Kn

F4=Pusinøu 0 Kn 0 Kn

F5= fcosøu (Pu+Wu-Pu/2) 134.671 Kn 134.671 Kn


F6= fcosøu (Pu+Wu-Pu/2) 34.637 Kn 34.637 Kn
Pd= Kn
Wu= Kn
Pu= Kn
F7= f'π (d + 2t) 20.969 Kn 20.969 Kn
F8= f'π (d + 2t) 0 Kn 0 Kn
F9=wHπt (d + t) 17.718 Kn 17.718 Kn
F10=wHπt (d + t) 17.718 Kn 17.718 Kn

TOTAL FORCES UPSTREAM & DOWNSTREAM:

FORCE Considering Expanding Considering Contracting


Condition Condition
∑F(us)= 802.695 Kn 491.415 Kn
∑F(ds)= 681.692 Kn 612.418 Kn

HOR. & VER. FORCES ACTING:

Considering Expanding Considering Contracting


FORCE
Condition Condition
Fh(us) = 695.154 Kn 425.578 Kn
Fv(us) = 401.348 Kn 245.708 Kn
Fh(ds)= 640.581 Kn 575.485 Kn
Fv(ds)= 233.152 Kn 209.459 Kn

TOTAL HOR. & VER. FORCES ACTING:


FORCE Considering Expanding Considering Contracting
Condition Condition
∑Fh =→+ 54.573 Kn -149.907 Kn
∑Fv =↓+ 168.196 Kn 36.249 Kn

ANCHOR SECTION PARAMETERS:


Length = 5m
Width= 3m
Section Area.= 13.73 m2
Length of pipe = 4.44 m
Vol. Of pipe= 2.82384 m3
Vol. Of anchor = 38.36616 m3
Wt. Of anchor = 920.78784 Kn

OTHER FORCES ACTING AT ANCHOR:

FORCE Considering Expanding Considering Contracting


Condition Condition
Equake Force1 = 95.422 Kn 95.422 Kn
Equake Force2 = 276.236 Kn 276.236 Kn

FACTOR OF SAFETY AGAINST OVERTURNING:

CONDITION Overturning Moment Resisting Moment

Considering Expanding 584.473 Kn-m 1597.442 Kn-m


Considering Contracting 498.249 Kn-m 1406.119 Kn-m

FACTOR OF SAFETY AGAINST SLIDING:

CONDITION SLIDING FORCE RESISTING FORCE


Considering Expanding 426.231 Kn 544.492 Kn-m
Considering Contracting 521.565 Kn 478.518 Kn-m

BEARING PRESSURE:
e1=(b/2)-(M/V) 1.57 m
e2= 1.551 m
b/3= 1.667 m
Q= Vt/A*(1-(6e/b)
CONDITION Qmin Qmax
Considering Expanding -64.177 Kpa 209.375 Kpa
Considering Contracting -54.947 Kpa 182.552 Kpa
Date: 03-Sep-18

ALYSIS
F.S.o Allowable REMARKS

2.733 1.5 SAFE


2.822 1.5 SAFE

F.S.o Allowable REMARKS


1.28 1.1 SAFE
0.92 1.1 NOT SAFE

Allowable REMARKS
260 SAFE
260 SAFE